power supply for buildings related hk ordinancesibse.hk/sbs5212/advancedelectrical_ordinance.pdf ·...

78
Power Supply for Buildings Related HK Ordinances By Dr. Y F KWOK Copyright 2015 1

Upload: duongnhu

Post on 22-Jun-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Power Supply for Buildings

Related HK Ordinances

By Dr. Y F KWOK

Copyright 2015

1

Electricity Ordinance (Cap 406)

Some Parts: Director of EMS

Some Parts: Electricity Suppliers

Part IV: Responsibility of Owners of Electrical Installations

Part VI: Electrical Products

Part VII: Electrical Workers and Contractors

3

Electricity Ordinance (Cap 406)

Cap 406D – Electricity (Registration) Regulations

Part II: REC

Parts III – V: REW

Cap 406E – Electricity (Wiring) Regulations

4

Electricity Ordinance (Cap 406)

Detailed requirements for Electrical Installations stipulated in the latest Code of Practice for the Electricity (Wiring) Regulations

5

Code of Practice for the Electricity

(Wiring) Regulations (2015 Edition)

6

Code of Practice for the Electricity

(Wiring) Regulations (2015 Edition)

7

Code of Practice for the Electricity

(Wiring) Regulations (2015 Edition)

8

Code of Practice for the Electricity

(Wiring) Regulations (2015 Edition)

9

Supply Rules (HEC)

Supply Voltage and Frequency

11

Supply Rules (HEC)

Supply Voltage and Frequency

12

Supply Rules (HEC)

Accommodation for Company’s Equipment

13

Supply Rules (HEC)

Accommodation for Company’s Equipment

14

Supply Rules (HEC)

Provision of Supply Cables and Equipment

15

Supply Rules (HEC)

Meter Position

16

Supply Rules (CLP)

Meter Position

17

Supply Rules (HEC)

Operation of Customer’s Installation

18

Supply Rules (HEC)

Customer’s Generating Plant

19

Supply Rules (HEC)

Customer Not to Supply Third Party

Extension of Supply to Other Customers by the Company

20

Supply Rules (HEC)

Voltage Fluctuation, Voltage Dip, Interruption or Failure of Supply

21

Supply Rules (HEC)

Customer’s Interference with Quality of Supply

22

Supply Rules (HEC)

Customer’s Interference with Quality of Supply

23

Supply Rules (CLP)

Customer’s Interference with Quality of Supply

24

Supply Rules (HEC)

Power Factor

Service Connection Charge

25

Supply Rules (HEC)

Metering of Electricity

Accuracy of Meter

26

Supply Rules (HEC)

General

27

Supply Rules (HEC)

Customer’s Main switch

28

Supply Rules (HEC)

Customer’s Main switch

29

Supply Rules (HEC)

Customer’s Main switch

30

Supply Rules (HEC)

Customer’s Main switch

31

Supply Rules (CLP)

Customer’s Main Switch

32

3

Supply Rules (HEC)

Communal Installation

33

Supply Rules (HEC)

Low Voltage Induction Motor

34

Supply Rules (HEC)

Low Voltage Induction Motor

35

Supply Rules (CLP)

Requirements of Customer’s Equipment

36

Supply Rules (CLP)

Change of Tariff

37

REW / REC Registration

39

REW / REC Registration

40

REW / REC Registration

41

Building Energy Efficiency

Ordinance (BEEO)

For

Newly constructed buildings

Major retrofitting works

Based on Building Energy Code (BEC)

Electrical Installation and Lighting system are services being regulated

43

Building Energy Efficiency

Ordinance (BEEO)

http://www.beeo.emsd.gov.hk/en/pee/BEC_2015.pdf

Also called Building Energy Code (BEC)

44

Building Energy Efficiency

Ordinance (BEEO)

Also for

Energy Audit

Registered Energy Assessor (REA)

45

Building Energy Efficiency

Ordinance (BEEO)

BEC 2015

Chapter 5 – Lighting Installation

Chapter 7 – Electrical Installation

Chapter 8 – Lifts and Escalators Installation

46

Building Energy Efficiency

Ordinance (BEEO)

BEC – Chapter 5 (Lighting)

Lighting Power Density (LPD)

Lighting Control Points (Nos.)

Automatic Lighting Control

Occupancy Control

Timer Control

Daylight Responsive Control

47

Building Energy Efficiency

Ordinance (BEEO)

BEC – Chapter 7 (Electrical Supply)

Power Distribution Loss

Motor Efficiency

Power Quality

Power factor

Harmonic distortion

Current balancing

Metering and Monitoring Facilities

48

Building Energy Efficiency

Ordinance (BEEO)

BEC – Chapter 8 Lifts & Escalators

Allowable Electrical Power

Utilisation of Power

Power Factor

Decoration Load

Lift Parking Mode

Lift MVentilationAC

49

Building Energy Efficiency

Ordinance (BEEO)

BEC – Chapter 8 Lifts & Escalators

Allowable Electrical Power

Utilisation of Power

…..

Regenerative braking

Lift Car Automatic Lighting Control

Automatic Speed Reduction of Escalators

Total Harmonic Distortion

Metering and Monitoring Facilities

50

Lifts and Escalators Ordinance

(Cap 618)

The Ordinance ensures the safety of lift and escalator by the following means:

Equipment compliance

Quality control

Safety examination

Setting of standards

…..

51

Lifts and Escalators Ordinance

(Cap 618)

The Ordinance ensures the safety of lift and escalator by the following means:

…..

Prosecution

Registration system

Public monitoring

Record keeping

52

Lifts and Escalators Ordinance

(Cap 618)

Equipment compliance

Lifts/escalators and their safety components are required to be of a type approved by EMSD.

53

Lifts and Escalators Ordinance

(Cap 618)

Quality control

Lift/escalator works such as installation, maintenance, repair, alteration and demolition of lifts/escalators are required to be undertaken by registered lift/escalator contractors ("RCs").

RCs are required to notify EMSD in respect of undertaking and subcontracting of lift/escalator works.

54

Lifts and Escalators Ordinance

(Cap 618)

Safety examination

Lift/escalator shall be thoroughly examined and certified in safe working order by registered lift/escalator engineers ("REs") before putting into use and operation, after major alteration; and periodically at interval not exceeding 1 year for lifts and 6 months for escalators.

55

Lifts and Escalators Ordinance (Cap

618)

Setting of standards

57

Lifts and Escalators Ordinance

(Cap 618)

Setting of standards

…..

RCs are required to attend to failures of emergency devices of lifts within 4 hours after the RCs become aware of the failures. The emergency devices of a lift include the alarm system, emergency lighting and intercommunication system and the ventilation fan.

….. 58

Lifts and Escalators Ordinance

(Cap 618)

Setting of standards

…..

If the failure of any emergency device cannot be rectified within 24 hours after the RC becomes aware of the failure, the RC must, before the end of the 24-hour period, notify EMSD of the failure in the specified form.

59

Lifts and Escalators Ordinance

(Cap 618)

Prosecution

The penalty levels of offences have been increased – the maximum fine is $200,000 and the maximum imprisonment period is 12 months.

EMSD is empowered to issue prohibition order, cessation order, examination order, removal order and improvement order.

60

Lifts and Escalators Ordinance

(Cap 618)

Registration system

The registration regime for RCs and REs is strengthened. RCs and REs are required to renew their registration every 5 years. In addition, a new registration system for lift /escalator workers is introduced.

…..

61

Lifts and Escalators Ordinance

(Cap 618)

Registration system

…..

Registers of RCs, REs and registered lift/escalator workers ("RWs") are maintained for public access.

REs and RWs are required to carry their registration cards at works.

Disciplinary actions can be taken against registered persons who have committed disciplinary offences.

62

Lifts and Escalators Ordinance

(Cap 618)

Public monitoring

The new use permit clearly indicates its validity period to promote "user surveillance“.

…..

63

Lifts and Escalators Ordinance

(Cap 618)

Public monitoring

…..

If there is an incident relating to a lift/escalator, the Responsible Person is required to notify within 24 hours after the incident comes to the person’s knowledge, in writing the EMSD and the RC.

…..

64

Lifts and Escalators Ordinance

(Cap 618)

Public monitoring

RCs are required to display a notice before the end of the 4-hour period after the RC becomes aware of the incident if the normal use and operation of the lift/escalator is suspended because of the incident.

65

Lifts and Escalators Ordinance

(Cap 618)

Record keeping

Responsible Persons are required to keep log-books.

RCs and REs are required to enter information into log-books and keep related records, such as the name and contact information of the sub-contractors if the works are subcontracted.

66

Lifts and Escalators Ordinance (Cap

618)

Responsible Persons

67

Lifts and Escalators Ordinance

(Cap 618)

Responsible Persons

(a) in relation to a lift,

(i) a person who owns the lift; or

(ii) any other person who has the management or control of the lift; and

(b) in relation to an escalator,

(i) a person who owns the escalator; or

(ii) any other person who has the management or control of the escalator;

(According to definition on Page 7 of the CODE OF PRACTICE FOR LIFT WORKS AND ESCALATOR WORKS)

68

Lifts and Escalators Ordinance (Cap

618)

Lift Modernisation

For existing lifts

Voluntary

Improve safety

7 recommended measures

69

Lifts and Escalators Ordinance (Cap

618)

Lift Modernisation

Double brake

Unintended car movement protection

Ascending car overspeed protection

Advanced car door mechanical lock / safety edge

…..

70

Lifts and Escalators Ordinance (Cap

618)

Lift Modernisation

…..

Intercom & CCTV

Obstruction switch for protecting suspension ropes

Automatic rescue device

71

References

1. Electrical and Electronic Technology by Edward Hughes, 10th Edition

https://docs.google.com/file/d/0B2s8MyO6hGENRl9BeTVTeUdRX2VHeGVTSEVOVFpyUQ/edit?pli=1

2. Electricity Ordinance (Cap 406)

http://www.legislation.gov.hk/blis_pdf.nsf/6799165D2FEE3FA94825755E0033E532/64775510C11F557B482575EF0003EE3E?OpenDocument&bt=0

3. Code of Practice for the Electricity (Wiring) Regulations (2015 Edition)

http://www.emsd.gov.hk/filemanager/en/content_443/COP_E_2015.pdf

4. Building Energy Efficiency Ordinance (Cap 610)

http://www.legislation.gov.hk/blis_ind.nsf/WebView?OpenAgent&vwpg=CurAllEngDoc*607.1*100*607.1#607.1

72

References

5. Code of Practice for Energy Efficiency of Building Services Installation, 2015 Edition. (or called Building Energy Code BEC)

http://www.beeo.emsd.gov.hk/en/pee/BEC_2015.pdf

6. Technical Guidelines on Building Energy Code (TG-BEC) 2012 Edition (Rev. 1) Chapter 7

http://www.beeo.emsd.gov.hk/en/pee/TG-BEC_2012%20(Rev.%201).pdf

7. Guidelines on Energy Efficiency of Electrical Installations, 2007

http://www.emsd.gov.hk/filemanager/en/content_725/Guidelines_on_Energy_Efficiency_of_Electrical_Installations_2007.pdf

73

References

8. Guide to Connection of Supply, HEC

https://www.hkelectric.com/en/customer-services/rules-standards-policies/guide-to-connection-of-supply

Chapter 3: Information on application of supply

https://www.hkelectric.com/en/CustomerServices/Documents/GuidetoConnectionofSupply_4.pdf

Chapter 6: Guidelines on design of electrical installation https://www.hkelectric.com/en/CustomerServices/Documents/GuidetoConnectionofSupply_7.pdf

9. Supply Rules, HEC

https://www.hkelectric.com/en/CustomerServices/Documents/SupplyRule_en_2008.pdf

74

References

10. Supply Rules, CLP

https://www.clp.com.hk/en/customer-service-site/open-and-close-account-site/supply-rules-site/Documents/supplyrules_eng_aug26_R3.pdf

11. CODE OF PRACTICE 101 FOR DISTRIBUTION SUBSTATION DESIGN Version 13.0, CLP

https://www.clp.com.hk/en/customer-service-site/open-and-close-account-site/cop-101-distribution-substation-design-site/Documents/cop101_v13jun2014_text.pdf

12. COP 215 for Load Assessment Procedure, CLP (Not available for downloading)

13. Electrical Installation Guide 2016, Schneider

https://www.schneider-electric.com/tools/registration/promo/US/en/changeCountry

75

References

14. Periodic Test for Fixed Electrical Installations (EMSD webpage)

http://www.emsd.gov.hk/en/electricity_safety/periodic_test_for_fixed_electrical_installations/

15. Guideline for Periodic Inspection, Testing and Certification (PITC) Work, EMSD

http://www.emsd.gov.hk/en/electricity_safety/information_for_the_electrical_trade/guideline_for_periodic_inspection_testing_and_cer/index.html

16. Leaflet PITC

http://www.emsd.gov.hk/filemanager/en/content_440/Leaflet_PITC.pdf

17. Electrical Installation Requirements, NEMA

https://www.nema.org/Standards/ComplimentaryDocuments/nec-iec60364.pdf

76

References

18. Lifts and Escalators Ordinance (Cap 618)

http://www.legislation.gov.hk/blis_pdf.nsf/6799165D2FEE3FA94825755E0033E532/1AC03E9DB719451C482579ED00535106/$FILE/CAP_618_e_b5.pdf

19. Building Energy Efficiency Ordinance (Cap 610)

http://www.legislation.gov.hk/blis_pdf.nsf/6799165D2FEE3FA94825755E0033E532/4F82C8740A5D73DA482577ED005330F2/$FILE/CAP_610_e_b5.pdf

20. Guidebook for Responsible Persons for Lifts (2012 Edition)

http://www.emsd.gov.hk/filemanager/en/content_826/RP_Guidebook_Lift_Instltn.pdf

21. Guidebook for Responsible Persons for Escalators (2012 Edition)

http://www.emsd.gov.hk/filemanager/en/content_826/RP_Guidebook_Escl_Instltn.pdf

77

References

22. Guidelines for Modernising Existing Lifts

http://www.emsd.gov.hk/filemanager/en/content_826/Modernising_Lifts.pdf

23. Inline Pumps with Fixed-speed Motor, Kolmeks

file:///C:/Users/Owner/Downloads/Kolmeks%20Pump%20catalogue%204%20Inline%20pumps%20-%20AE,%20L,%20AL%20and%20AKN.pdf

78