Page 1: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

PowerLogic PowerView v2.0 software

Page 2: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 2- North American Operating Division

PowerLogic PowerView v2.0

●New native support for devices

●Software updates

●New PDI tool (PMC usage)

●Target availability is October 2008.

Page 3: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 3- North American Operating Division

Supported Devices● The list of Supported Devices are:

●Power Meter 210

●Power Meter 500

●Power Meter 710,750

●Power Meter 810, 820, 850, 870– M22, M2222 and M26 extended I/O modules

●Enercept

●ION 6200

●Micrologic Trip Units Types P, H and A

● Maximum number of Devices:●The maximum number of devices for this software application is 32.

Page 4: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 4- North American Operating Division

Device Communications to devices

●Device Connections● Automatic Detection (Auto discovery of networked devices)

●Software polls the network for supported devices ●User may “speed up” the detection process with scan options●Devices are automatically named but can be re-configured by user

● Manual connections●End users will have the option to manually add and delete device connections.

● Supports Ethernet gateways, including EGX models and PM8ECC

●Communications ● Supports Ethernet gateways, including EGX models and PM8ECC

● Devices with communication issues are highlighted in red

Page 5: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 5- North American Operating Division

Auto Detection of Devices

Page 6: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 6- North American Operating Division

Selective Scan Option

Page 7: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 7- North American Operating Division

Data Logging● Onboard Data Logging:

●The Power Meter 800 (PM800) family will perform onboard data logging●The PM800 onboard logging interval is set in PMCU. PowerView Software will upload at regular 2 hour intervals automatically.

● PC-based Data Logging:●The Power Meter 210, Power Meter 710 & 750, and Micrologic Trip Units A, P and H will perform PC-based data logging.

●The PC-based data logging interval default is 15 minutes.●The PC-based data logging interval can be changed by the end user.●The measurements that are PC based data logged cannot be modified.

● Quantities (measurements) Logged:●Current●Voltage●Power●power factor●energy,●demand power●demand current●total harmonic distortion (THD).

Page 8: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 8- North American Operating Division

Database Management

●Database Backups:●The option to backup the database will be available.

●Database Restores:●The option to restore the database will be available.

●Historical Database Management:●The Historical database will be maintained below 2.9 GB in size.

●Data will be deleted from the Historical database as first in – first out (FIFO) to prevent growth over 2.9GB.

●Deleted Historical data is not retained.

Page 9: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 9- North American Operating Division

Real Time Display – Summary View

Page 10: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 10- North American Operating Division

Report Builder●Basic Queries:

● Device(s) + Measurement(s)+ time range= Output (trends, charts, tables)● Both PC and Onboard (PM8’s) data available in database.

●Pre-configured Queries:● Focused on providing end user with historical information on their Electrical Energy

usage and power demand.●Energy usage for last day, week, month●Energy TOU (Time of Use) or Energy Bands outputs

● Support for Time of Use Metering includes.●defining up to 3 schedules●Each Schedule can contain

-> up to 10 periods (bands) for energy accumulation-> Supports weekends, special days, holidays

●Reports Viewer:● End user will be expected to have Microsoft Excel to view reports.

●All costing and other calculations (eg. Terrifications, rates) can be done manually by the customer in Excel.

Page 11: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 11- North American Operating Division

General Report Example

Page 12: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 12- North American Operating Division

Report Builder

Page 13: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 13- North American Operating Division

Export the Data

Page 14: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 14- North American Operating Division

Time of Use Setup

Page 15: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 15- North American Operating Division

Time of Use Setup

Page 16: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 16- North American Operating Division

Time of Use Setup

Page 17: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 17- North American Operating Division

Time of Use Setup

Page 18: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 18- North American Operating Division

Time of Use Setup

Page 19: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 19- North American Operating Division

Appendix A – Data Logging per Device

Page 20: PowerLogic PowerView v2.0 software. Schneider Electric 2 - North American Operating Division PowerLogic PowerView v2.0 ●New native support for devices

Schneider Electric 20- North American Operating Division

>

Questions ?