powerwall (-c, -e) installation - fronius draftt30 · powerwall part numbers: 1067000-00-c,...

6
Powerwall Part Numbers: 1067000-00-C, 1067000-00-E POWERWALL (-C, -E) INSTALLATION - FRONIUS WALL MOUNTING TRANSPORTATION © 2017 Tesla ONLY AT JOB SITE 10 mm 17 mm (-C only) T20 T30 DRAFT

Upload: others

Post on 25-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: POWERWALL (-C, -E) INSTALLATION - FRONIUS DRAFTT30 · Powerwall Part Numbers: 1067000-00-C, 1067000-00-E POWERWALL (-C, -E) CONNECTIONS - FRONIUS Twisted Pair + Shield Powerwall Terminal

Powerwall Part Numbers: 1067000-00-C, 1067000-00-E

POWERWALL (-C, -E) INSTALLATION - FRONIUS

WALL MOUNTING TRANSPORTATION

© 2017 Tesla

ONLY ATJOB SITE

10 mm17 mm (-C only)

T20T30DRAFT

Page 2: POWERWALL (-C, -E) INSTALLATION - FRONIUS DRAFTT30 · Powerwall Part Numbers: 1067000-00-C, 1067000-00-E POWERWALL (-C, -E) CONNECTIONS - FRONIUS Twisted Pair + Shield Powerwall Terminal

Powerwall Part Numbers: 1067000-00-C, 1067000-00-E

POWERWALL (-C, -E) CONNECTIONS - FRONIUS

Twis

ted

Pai

r+

Sh

ield

Powerwall Terminal Name Wire Color Wire Gauge Strip Length

(Powerwall Side)Fronius Inverter Terminal Name

Strip Length (Inverter Side)

Ground Green/Yellow 2.5—6 mm2 (14—10 AWG) 8—12 mm (5/16—1/2 in) BAT PE 15 mm (5/8 in)

DC Power + Red 2.5—6 mm2 (14—10 AWG) 12—16 mm (1/2—5/8 in) BAT + 15 mm (5/8 in)

DC Power — Black 2.5—6 mm2 (14—10 AWG) 12—16 mm (1/2—5/8 in) BAT — 15 mm (5/8 in)

Enable Orange 0.2—1 mm2 (24—18 AWG) 7—9 mm (9/32—3/8 in) IO 1

Logic Power (+) Brown 0.2—1 mm2 (24—18 AWG) 7—9 mm (9/32—3/8 in) + (12 V+)

Logic Return (—) White 0.2—1 mm2 (24—18 AWG) 7—9 mm (9/32—3/8 in) — (12 V—)

Comm Hi (+) Blue 0.2—1 mm2 (24—18 AWG) 7—9 mm (9/32—3/8 in) D+

Comm Lo (—) Yellow 0.2—1 mm2 (24—18 AWG) 7—9 mm (9/32—3/8 in) D—

DRAFT

Page 3: POWERWALL (-C, -E) INSTALLATION - FRONIUS DRAFTT30 · Powerwall Part Numbers: 1067000-00-C, 1067000-00-E POWERWALL (-C, -E) CONNECTIONS - FRONIUS Twisted Pair + Shield Powerwall Terminal

Powerwall Part Numbers: 1067000-00-C, 1067000-00-E

POWERWALL (-C, -E) COMM WIRING INSULATION - FRONIUS

DRAFT

Page 4: POWERWALL (-C, -E) INSTALLATION - FRONIUS DRAFTT30 · Powerwall Part Numbers: 1067000-00-C, 1067000-00-E POWERWALL (-C, -E) CONNECTIONS - FRONIUS Twisted Pair + Shield Powerwall Terminal

Powerwall Part Numbers: 1067000-00-C, 1067000-00-E

POWERWALL (-C, -E) DC WIRING - FRONIUS

Note: Use 15A inline PV fuses/Sunclix provided by Fronius

GND

DC +

BAT + BAT – BAT PE

DC –

Powerwall Thermal Controller board

Fronius Symo Hybrid DC Connectors

DRAFT

Page 5: POWERWALL (-C, -E) INSTALLATION - FRONIUS DRAFTT30 · Powerwall Part Numbers: 1067000-00-C, 1067000-00-E POWERWALL (-C, -E) CONNECTIONS - FRONIUS Twisted Pair + Shield Powerwall Terminal

Powerwall Part Numbers: 1067000-00-C, 1067000-00-E

POWERWALL (-C, -E) COMM WIRING - FRONIUS

D–13579 –– D –13579 ––

Notes: • Powerwall -E units include factory-installed cable connected to Thermal Controller board• Terminate shield at inverter only

COM LO (–)COM HI (+)LOGIC –LOGIC +ENABLE

SHIELD

Powerwall Thermal Controller board

Fronius Symo Hybrid DATCOM Connectors

+ +

– D –

D +

9

8

7

6

5

4

3

2

1

0

DRAFT

Page 6: POWERWALL (-C, -E) INSTALLATION - FRONIUS DRAFTT30 · Powerwall Part Numbers: 1067000-00-C, 1067000-00-E POWERWALL (-C, -E) CONNECTIONS - FRONIUS Twisted Pair + Shield Powerwall Terminal

Powerwall Part Numbers: 1067000-00-C, 1067000-00-E

POWERWALL (-C, -E) SWITCH SETTINGS - FRONIUS

CAN-Modbus Switch Termination Switch

Address Switches

en-REV_01_170126

Communication Protocol Switch Position

Modbus (RS485) Right

Termination Switch Position

Termination WITH Modbus bias Bottom

Address Switch Switch Position

Switch 1 Right

Switch 2 Right

Switch 3 RightDRAFT