present state of the gilda beamline...gilda: a beamline for xas on diluted samples and thin films...

22
F. d'Acapito, CNR-IOM-OGG 1/22 Present state of the GILDA beamline F. d'Acapito, CNR-IOM-OGG

Upload: others

Post on 06-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 1/22

Present state of the GILDA beamline

F. d'Acapito, CNR-IOM-OGG

Page 2: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 2/22

Layout

Description of the beamline

Beamline statistics

Experimental examples

Perspectives

Page 3: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 3/22

Beamline description

Page 4: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 4/22

X-ray optics

1st collimating mirror Cylindrical, 3*0.5m sections Pd and Pt coatings Cutoff 18 & 31 keV.

Sagittally focusing monochromator Si(111), Si(311), Si(511) xtals

2nd vertically focusing mirrorCylindrical, 1mPd and Pt coatings

LE-HRM

Energy range4-90 keV Flux1011ph/s → 109 ph/s Beam size

0.5*2 mm² → 0.2*0.2 mm2

Page 5: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 5/22

XAS

2 vacuum chambers L-N

2 – L-He cryostat

Cell for gas-solid reactions Cryostat for liquid samples

2 HP-Ge detectors

3 ICs, sample+reference

TEY, XEOL

ReflEXAFS, GIXAS

Page 6: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 6/22

XRD

Acquisition implemented under SPEC Breakdown of the old IP reader Use of a MAR 345 detector from the Pool Activity eventually abandoned needing considerable resources for refurbishment

Hot air blower

MAR345

Photodiode

Page 7: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 7/22

Interventions in the last 5 years

Adoption of SPEC

Migration to ICEPAP controllers

One-click beamline alignment

5.5-90 keV range available without mechanical interventions

CARD software for ReflEXAFS

Surface Elemental mapping

Strobo Time resolved studies

Si(755) Si(311)

Page 8: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 8/22

Beamline statistics

Page 9: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 9/22

Users

Growth of some communities (environment, cult. Heritage) in the latest years.

Users mainly from Italy

Page 10: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 10/22

Experiments

15-18 shifts per experiment on average

No support for CRG users

2009 2010 2011 2012 20130

20

40

60

80

100

120

2009 2010 2011 2012 20130

5

10

15

20

25

30

35

40

Experimental sessions

Visits

Page 11: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 11/22

Publications

~>30 pubs/y

Average IF=3

20% from internal activity

Page 12: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 12/22

Staff

On site Responsible → F.

d'Acapito

Scientist → A. Trapananti

Post Doc → S. Torrengo

Non resident technical support V. Tullio → INFN-LNF

A. Martin → CNR-IOM

Page 13: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 13/22

Experimental examples

Page 14: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 14/22

Il battesimo di Gesù, A. Signorelli XV cen

Electron Microprobe maps of a discolored grain

Page 15: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 15/22

XAS results

Ab-initio TD-DFT simulation of the optical absorption based on EXAFS data

Page 16: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 16/22

Supramolecular assembly of block copolymers

Molecular tiles

Time resolved XRD study

Page 17: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 17/22

Results

Formation of ordered structures at 545 K

Stabiity of the polyhedra up to 453K

Page 18: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 18/22

Project for a new beamline

Page 19: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 19/22

Layout

Present Lattice & optics New Lattice & opticsPresent Lattice & New optics

*120 times flux in a Ø50m pinhole

Page 20: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 20/22

Scientific activities

GI- or Refl- XAS in linear dichroism

Pollutant-surface interaction

Thin films

Large area valence state/simmetry mapping

Cultural heritage

Stroboscopic time resolved studies

Photosensitive systems

Ferroelectrics

High quality transmission XAS

Chemistry

Quick XAS

Gas-solid reactions

High resolution fluorescence

High resolving power

Multiple pollutants in soils and airborne dust

X-ray emission spectroscopy

Valence/spin states

High energy XPS

Chemical characterization of buried systems

Electronic devices

Page 21: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 21/22

Timetable & funding

Phase 0

Design and preparation of the calls for tender

Phase 1

Refurbishment of the X-ray optics

Phase 2

Refurbishment of the experimental apparata & detectors

2014 → 0.5 M€

2015 → 0.5M€

2016 → 0.5 M€ (to be confirmed)

Page 22: Present state of the GILDA beamline...GILDA: a beamline for XAS on diluted samples and thin films Renewal of instrumentation → simpler BL operation 25 expts, 30 pubs, 80 visits

F. d'Acapito, CNR-IOM-OGG 22/22

Summary

GILDA: a beamline for XAS on diluted samples and thin films

Renewal of instrumentation → simpler BL operation

25 expts, 30 pubs, 80 visits / year

New project for an improved beamline Now mostly funded