Prestige 2com trunking is designed to meet the needsof current and future data cabling.

Prestige 2com is Cat 6 compliant and providesmaximum capacity for data cabling.

Cat 6 compliant50mm radius bends on all corners so cables lie in trunking correctly to avoidany deformation which may result in signal distortion and loss. Complieswith and exceeds Cat 5/5e wiring regulations. Ideal also for futurerefurbishments using upgraded computer cables – Cat 6E/7

Maximises capacity60mm deep trunking with two equal compartments to maximise datachannel cabling

Flexible accessoriesAccessories can be mounted on either or both compartments – enablesmaximum use of wiring space in one compartment

Frames maximise spaceMounting frames for LJU6/Euro data outlets to maximise use of space

Stylish and robustSingle piece end caps, corners and couplers for improved aesthetics andsolid construction. Screw fix option for security of fitting (corners)

Pre-drilled trunking basesEliminates the need to measure and drill fixing holes on site thus reducinginstallation time

range introduction

cable management | perimeter and distribution

Features

Prestige Plus Aluminium with Edge sockets in Black Anodised Aluminium

END CAPS

Neatly finish runs of

trunking. Supplied as sets

of right and left hand pairs

including retainers and

covers

One-piece cover simplifies

installation

MAIN CARRIER

Pre-drilled at 100mm centres for ease

and speed of installation

INTERNAL CORNER

One-piece cover simplifies

specification and

installation. Each assembly

is supplied with clip-on

cover and moulded corner

carrier

Data bend component with

50mm Radius

Screw fix option

Unobtrusive screw fixings

to maximise security

against tampering

AESTHETIC PROFILE

Stylish, contoured elegance

CABLE RETAINERS

Hold cables securely

in place

COVERS

Clip-on to complete

assembly and conceal

wiring

ACCESSORY MOUNTING BOXES AND FRAMESAll boxes have facility to ‘knockout’ back for greater depth.

35mm boxes for larger cabling size requirements, deep accessories,

data and power

Accessories can be mounted in either or both compartments

Features

cable management | perimeter and distribution

MINI TRUNKING

ADAPTORS

For cable

distribution to

and from Prestige

2com a range of

MK mini trunking

and Egatube

Conduit can be

used

CABLE DIVIDER

Sub-divides

internal

compartments

2 COMPARTMENTS

For maximum data

cable capacity

complete compartment

area can be used

EXTERNAL CORNER

One-piece cover component for ease of

assembly and styling. Each assembly is

supplied with clip-on cover and moulded

corner carriers.

Data bend component with 50mm

Radius.

Screw fix option

Unobtrusive screw fixings to maximise

security against tampering

COUPLER

One-piece cover

component for ease

of assembly. Each

assembly is supplied

with carrier moulding

and clip-on cover

(not shown above)

FLAT TEES AND ANGLES

These enable the Prestige 2com

trunking configuration to follow

the contours of the installation

in the vertical plane and include

50mm radius inserts to ensure

continued data cable protection

EMC SCREENING

Aluminium screening inserts

provide an effective screen

for computer service cables

and can be used in either

compartment

CROSSOVER

BRIDGE

Permits cabling to

cross from one

cable

compartment to

another within the

assembly, whilst

maintaining

segregation

CouplerAssembly

Lid Joint Cover

InternalCornerAssembly

CONSISTS OFCOVER ANDCARRIER

DIMENSIONS210 X 60MM

ExternalCornerAssemblyCONSISTS OFCOVER, CARRIERAND RADIUSINSERT

End CapCover andRetainer

Main Carrier

Straight Cover

End CapAssembly

CableRetainer

CrossoverBridge

MiniTrunkingAdaptor

TrunkingAdaptor50 X 50mm

VTS/2001 WHI3 METRE LENGTHS

VTS/2001 D1 WHI2 METRE LENGTHSFOR (NON UK) MARKETS

NOT SUPPLIED WITHLID (COVER)

4m

6m VTS/5 WHI3 METRE LENGTHS

VTS/5 D1 WHI2 METRE LENGTHSFOR (NON UK) MARKETS

NOTE each main carrierrequires two straight covers

20m

30m

VTS/2081 WHIYT1-YT3 MINI TRUNKING ADAPTOR.USE APPROPRIATE YEA ADAPTOR (YEA1-YEA3) TO CONNECT MINI TRUNKING

VTS/2084 WHIYT4 MINI TRUNKING ADAPTOR

10

10 VTS/2050 WHI50 X 50MM TRUNKING ADAPTOR

10VTS/2015 WHIEND CAP RETAINER

VTS/2016 WHIEND CAP COVER

1

1 VTS/2090 WHICROSSOVER BRIDGE

10VTS/2011 WHICABLE RETAINER

10VTS/2006 WHIEND CAP ASSEMBLY

2

VTS/2005 WHI 2 VTS/2010 WHIUSED TO JOIN 2 COVERPIECES AT REMOTE POINTFROM COUPLER

10 VTS/2004 WHIINCLUDES ADDITIONAL SCREW FIXING FOR EXTRA SECURITY50MM RADIUS BEND

1 VTS/2003 WHIINCLUDES ADDITIONAL SCREW FIXING FOR EXTRA SECURITY50MM RADIUS BEND

1

cable management | perimeter and distribution

Features

Cable Divider

MountingFrames

3 METRELENGTHS

Corner Covers

INTERNAL ANDEXTERNAL

Radius Insert

Corner Carrier

EXTERNALCORNER

INTERNAL ANDEXTERNAL

Socket Spacer

MCB/RCDHousing

Conduit/BlankAdaptor

VTS/2020 WHICONDUIT/BLANKADAPTOR WITH DRILL LOCATION.WILL ACCEPT 20/25MMCONDUIT

10

VTS/2030 WHIEXTERNAL CORNER COVER

VTS/2040 WHIINTERNAL CORNER COVER

1

1 VTS/2007 WHIINTERNAL CORNER CARRIER

VTS/2008 WHIEXTERNAL CORNER CARRIER

1

1 VTS/2009 WHI50MM RADIUS BEND INSERT FOR DATA CABLESEXTERNAL CORNER

1

VTS/25 S WHIACCESSORY SOCKET SPACERTO ESTABLISH THE MINIMUM DISTANCE BETWEEN OUTLETS

10

VTS/50 CABLE DIVIDER3 METRE LENGTHS

30m

VTS/2060 WHI2 GANG LJU6C/RJ45SUPPLIED WITH LID JOINT COVERS

VTS/2070 WHI2 GANG EURO/RJ45SUPPLIED WITH LID JOINT COVERS

10

10VTS/KMH/1 WHIVTS/MH WHIMCB/RCD HOUSINGWITH COVER

1

1

VTS/2070 WHI

VTS/2060 WHI

VTS/7000 WHI

VTS/6000 WHI

VTS/6000 WHI1 GANG ACCESSORY MOUNTING FRAME

VTS/7000 WHI2 GANG ACCESSORY MOUNTING FRAME

5

10

EMCScreening

VTS/2112OUTLET BOX ACCESSSECTION

1VTS/2111SCREENING INSERT

6m 21017SST9SPARE BONDING KIT

5

Flat Tee Flat Angle

AccessoryBoxes

VTS/6025 WHI1 GANG 25MM DEEP

VTS/6035 WHI1 GANG 35MM DEEP

VTS/2017 WHIBOX ADAPTOR

10

25

25 VTS/7025 WHI2 GANG 25MM DEEP

VTS/7035 WHI2 GANG 35MM DEEP

VTS/8028 WHI3 GANG 28MM DEEP

5

10

10

VTS/7035 WHIVTS/6035 WHI

VTS/2014 WHI50MM RADIUS BEND

1 VTS/2012 WHI50MM RADIUS BEND

1

VTS/2017 WHI

VTS/2111

VTS/8028 WHI

VTS/25 S WHI

VTS/4545 WHIFLAT ADAPTOR PLATE (NON UK)45MM X 45MM APERTURE

VTS/4545R WHIRAISED ADAPTOR PLATE (NON UK)45MM X 45MM APERTURE

VTS/35B WHIADAPTOR PLATE BASE(NON UK)

10

10

10

VTS/4545 WHI VTS/4545R WHI NCT/1G25 WHI

VTS/25 S WHIACCESSORY SOCKET SPACERTO ESTABLISH THE MINIMUM DISTANCE BETWEEN OUTLETS

K3716BOX EARTH TERMINAL

100

10

cable management | perimeter and distribution

Features

Data Trunking System

Description

The Prestige 2com trunking is a symmetrical two compartment system offering a Cat 6 flexible solutionto routing data cabling whilst maintaining the required slow bend radius of 50mm, with a separatecompartment for power cables. The trunking is normally surface mounted at dado or skirting heightbut may also be used vertically. The covers are of the snap-on type with the option of screw fixing foradded security against vandalism. Special accessories include adaptors for connection to the full rangeof MK mini trunking.

Materials

All components are manufactured from PVCu. Carriers, covers and cable dividers are extruded. Carriercouplers, corner carriers, stop ends and accessory boxes are formed by injection moulding.

Colours

The system is available in a standard white colour, with a choice of over 180 RAL paint colours onspecial orders.

Outlets

The system is designed to accommodate the complementary range of Logic Plus switches and sockets.Other MK wiring devices may also be used.

l System bend radius 50mmMeets Cat 56 data cable requirements

l Attractive styling complementary toLogic Plus

l Aesthetic one piece fitting coverswith carriers

l Two equal compartments – maximiseswiring channel capacity

l Accessory mounting in either or bothcompartments – givingflexibility/versatility

l Unobtrusive screw fixing covers tomaximise security against tampering

l Ease of installation – butt jointedconstruction, no mitring required

l Economical – cost effective 3components (2 x lids 1 base)

l Suitable for skirting or dado mounting

l Pre-drilled base – ease/speed ofinstallation

l Accommodates matching MK and otherBS switches and sockets

l Interfaces with MK Premier, and EgaIndustrial and Ega Mini Trunking andconduit Systems

l Strong PVCu sections are resistant toimpact

l Manufactured to high precisionstandards

l Full range of components, spares andaccessories

l Mounting frames for LJU6/Euro dataoutlets – cost effective, minimum spacerequirement (for mounting in SELVcompartment only).

l Choice of 180 RAL paint colours

Features

Prestige 2com Technical

Data Trunking System

Dimensions (mm)

VTS2001 main carrier+ 2 x VTS5straight covers

Weight:

2.41 Kg/m

Flat angle Flat tee

Flat angles and tees

These components arefabricated sections and spacemust be allowed for theirinclusion in runs of trunking.All other components snapon over standard trunkingprofiles.

DIMENSIONS (mm)

Flat angle A B

VTS2012 310 210

Flat T details A B C D

VTS2014 310 210 410 210

Components

Wall thickness:

VTS2001 = 2.5mm, 2.0mVTS5 = 1.7mm

60

210

1

1

A

A

B

B

C

B

D

A

PRESTIGE 2COM CABLE CAPACITY

Type of Size Cable Cmpt 1 Cmpt 1 Cmpt 1 Cmpt 1 withConductor Factor with 25mm with 35mm Ext Corner

back box back box 50mm DataBend

Full Term CSA 100% Fill (mm2)

4466 2236 1633 3132

Term at 45% Fill (mm2)

2009 1006 734 1409

Power Cables Number of Cables at 45% Fill

PVC Stranded 1.5mm2 8.6 233 116 85 163

2.5mm2 12.6 159 79 58 111

4mm2 16.6 121 60 44 84

6mm2 21.2 94 47 34 66

Data Cables Number of Cables at 45% Fill (a) and Full Capacity (b)

a b a b a b a b

Cat5E UTP 5.5mm dia. 30.2 66 147 33 74 24 54 46 103

Cat5E STP 6.0mm dia. 36.0 55 124 27 62 20 45 39 87

Cat6E UTP 6.5mm dia. 42.2 47 105 23 52 17 38 33 74

Cat6E STP 7.0mm dia. 49.0 41 91 20 45 14 33 28 63

cable management | perimeter and distribution

Prestige 2com Technical

Data Trunking System

15mm*to wall

34mm*

118mm*

34mm*

118mm*

15mm*

15mm*

190mm*

End Cap Assembly

VTS/2006

Internal CornerAssembly

VTS/2003

Coupler Assembly

VTS/2005

Flat Tee

VTS/2014

Flat Angle

VTS/2012

Component selection guide

VTS/2001

VTS/5

VTS/5

External CornerAssembly

VTS/2004

* Minimum distance

Data Trunking System

34mm

13mm

1

2

3

4

5

6

Installation guide

1. Surface to which the trunking is to be installed should be flat andprepared for decorating.

2. Establish the layout of the trunking run with particular attention tothe following: -

a. Changes in direction of the trunking.

b. The position of any feeds to or from the system.

c. The position of any connections with existing trunking/wiringsystems.

d. Allow for minimum distances between corners, couplers,screw fixings, angles and T’s (please see individual technicalsections for details).

e. When installing at skirting level, ensure room is also allowedfor future floor coverings to be fitted below trunking.

General installation guidelines

Tools and sundries required for installation:

1. Fine toothed tenon saw or a hacksaw with a 32 – 26 TPI blade forcutting the trunking, or preferably a circular saw with a 350mmdiameter fine tungsten tipped blade (100TPI approx.)

2. All purpose knife or fine file for trimming of trunking

3. Spirit level, Plumb Bob and chalk line

4. A range of screwdrivers (flat or cross point) to suit fixing screws andEarth Carrier Connectors

5. A 5.5mm Ø drill bit and No.8 Round head or Pan head screws withsuitable washers to secure the trunking.

6. Soft faced mallet to aid lid fitting

Planning the Installation

It is important to spend some time planning the installation, beforestarting. Time spent on planning the layout at this stage can avoidmistakes later on. The installation is designed for a non-conductivesubstrate, if you have any queries please contact: MK Technical SalesService Department.

cable management | perimeter and distribution

Prestige 2com Technical

Data Trunking System

118mm

100mm max

100mm max

34mm

210mm

34mm

500mm max

47mmwide

70mmwide56mm

deep

34mm

deep

7

8

9

10

General notes

Prior to installation strike a line of trunking usinga plumb and chalk line for vertical, and spiritlevels for horizontal runs.

Drill Holes in supporting walls prior to fixing

When mounting at skirting level allowanceshould be made for thickness of floor finish

Start Installation at a corner position

Profile N begin by clipping Corner Extensionsto their respective Corner Carriers

Debur all carrier cut ends

Carrier couplers must be placed at alljunctions between carriers

Leave a gap of 5mm for expansion in longruns

Fixings require washers and domed headscrews

Fixings to be at 500mm centres and also atpoints within 100mm of each end

Cut trunking to allow for mini trunking /conduit 10a and box adaptor crossoverbridge, 10b.

1

2

3

4

5

6

7

8

9

10

Data Trunking System

13mm

for joint

cove

r

Trunking Covers to be cut 8-10mm shorter than Trunking Base

Cen

tre

13

14

15

16

17

18

11

E

19

Debur all cover cut ends

Insert accessories in the following order

a Box adaptor

b Accessory Boxes

c Appropriate slide (VTS2081 shown)

d Cross over bridge

e External Corner Radius (into the Data/Telecom compartment)

Power Cables

Data / Communication cables

Mark position where mains entry is required

Installation guide continued

13

14

15

11

12

cable management | perimeter and distribution

Prestige 2com Technical

Data Trunking System

1 gang 76mm 2 gang 137mm 3 gang 197mm for outlet boxes

88mmfor minitrunkingadaptor

A

B

C

D

17

18

Drill 4.5mm dia. clearance hole to allow fixing of screw.

Figure 1

16

17

18

19

Fit covers by locating them correctly into position andpushing them firmly to snap in place

Determine whether corners need to be screw fixed (Fig 1).Continue to locate correctly the Corner and Joint covers andpush them firmly until they snap into place. Fit theappropriate badge to the Corner Covers.

Fit covers by locating them correctly into position andpushing them firmly to snap in place

Fit end caps by pushing them on from the front so the clipsslide behind the retainers and engage in the main carrier.

MK ELECTRICMK Electric (Singapore) Pte Ltd8 Pandan Crescent, UE Tech Park Telephone : (65) 6461 6333 Facsimile : (65) 6461 6336 / (65) 6461 6338#01-06 (LL4), Singapore 128464

MK Electric (Malaysia) Sdn Bhd(Co. No. 39068-A)Komplek Perusahaan LTAT Telephone : (603) 5519 4507 Facsimile : (603) 5510 8867Jalan Pengapit 15/19, 40000 Shah AlamSelangor Darul Ehsan, Malaysia

MK Electric (China) Ltd5F, Prosperity Centre, 77-81 Container Port Road Telephone : (852) 2834 1988 Facsimile : (852) 2834 0012Kwai Chung, New Territories, Hong Kong

PT. MK Electric (Indonesia)Mangga Dua Harco Blok E25, Floor 4 Jakarta 10730 Telephone : (62) 021 625 6204 Facsimile : (62) 021 612 1987

Website www.mkelectric.com.sg Publication No: Prestige_2com0407