  • 8/12/2019 PRfiles Related to MBLB_BLHO

    1/6

    1 Nokia Siemens Networks 2012

    For internal use

    Unique document identifier (ID) / Version number / Life cycle status

    PRFILE

    Dept. / Author / Date

    PRFILE Recommended ValueRNC

    117 120 121

    002:1900 1 Hex 0 0 1

    002:1888 2 Hex B B B

    002:1897 1 Hex 1 1 1

    002:1765 243C Hex 0 0 243C

    Megamon Log is needed to verify the activation of PRFILE

  • 8/12/2019 PRfiles Related to MBLB_BLHO

    2/6

    2 Nokia Siemens Networks 2012

    For internal use

    Unique document identifier (ID) / Version number / Life cycle status

    Dept. / Author / Date

    Parameter 002:1900 RN60_MAINT_25

    Descriptive nameRNC workaround for UE problem

    Applicable controllers

    cRNC, mcRNC, I-HSPA Adapter

    ModifiableYES

    DescriptionWith this workaround active RNC delivers maxReportedCellsOnRACH as CurrentCell, when RACH Intra Frequency Measurement Quantity is CPICH-RSCP in SIB1

    After the parameter value has been changed, the change is implemented within 10 minutes.

    Default value(s)

    0HAllowed values

    0H/1H

    Forbidden values-

    Dependence

    Dependence on other parameters does not exist.Feature

    -

  • 8/12/2019 PRfiles Related to MBLB_BLHO

    3/6

    3 Nokia Siemens Networks 2012

    For internal use

    Unique document identifier (ID) / Version number / Life cycle status

    Dept. / Author / Date

    Parameter 002:1888 RN60_MAINT_12

    Descriptive nameRNC workaround to UE problems with blind IFHO for PS services.

    Applicable controllers

    cRNC, mcRNC, I-HSPA Adapter

    ModifiableYES

    Description

    PRFILE parameter controllable workarounds are implemented to the RNC. This can be activated/deactivated for PS and CS service.If activated for CS, the RNC will do blind IFHO for AMR RAB in Cell_DCH state in two stages:

    1. IFHO using Physical Channel Reconfiguration, Transport Channel Reconfiguration or Radio Bearer Reconfiguration procedure.

    2. RB setup.If activated for PS, the RNC will do blind IFHO for PS RAB in Cell_DCH state in two stages:

    1. IFHO using Physical Channel Reconfiguration, Transport Channel Reconfiguration or Radio Bearer Reconfiguration procedure.

    2. RB setup.

    It is also possible to prevent (with Bit4) a blind IFHO for R99 capable UEs in PS NRT RAB setup.The following list of default and possible values:

    Default value of this parameter is 0H. With this value the workaround is disabled.

    To activate CS workaround, the values of Bit0 and Bit3 need to be set to 1.

    To activate PS workaround, the value of Bit1 needs to be set to 1.

    To activate both CS and PS workarounds, the values of Bit0, Bit1, and Bit3 need to be set to 1.

    To activate the prevention for blind IFHO for R99 capable UEs in PS NRT RAB setup, the value of Bit4 needs to be set to 1.

    To ensure that with PS workaround the same transport channel which is used in the source cell is kept in the target cell, the value of Bit5, needs to be set to 1.

    To ensure that with PS workaround, if the source cell RSCP is good enough, the 2 ms TTI allocation for E-DCH in the target cell is possible in RB setup, the value of Bit6, ne

    After the parameter value has been changed, the change is implemented within 10 minutes.

    Forbidden values

    DependenceDependence on other parameters does not exist.

    Feature

  • 8/12/2019 PRfiles Related to MBLB_BLHO

    4/6

    4 Nokia Siemens Networks 2012

    For internal use

    Unique document identifier (ID) / Version number / Life cycle status

    Parameter 002:1897 RN60_MAINT_22

    Descriptive name

    Usage of monitored cell measurement results on RACH to define the source cell for blind IFHO.

    Applicable controllerscRNC, mcRNC, I-HSPA Adapter

    Modifiable

    YES

    DescriptionWith this PRFILE parameter, it is possible to disable the use of monitored cell (intra-frequency neighbor cell) in RACH measurement results. This means that blind IFHO can be triggered only from t

    cells RSCP value is used when defining the initial power for blind IFHO.

    Default value(s)0H

    Allowed values

    0H/1H

    Forbidden valuesDependence

    Dependence on other parameters does not exist.

    Feature

    -

  • 8/12/2019 PRfiles Related to MBLB_BLHO

    5/65 Nokia Siemens Networks 2012

    For internal use

    Unique document identifier (ID) / Version number / Life cycle status

    Dept. / Author / Date

    Parameter 002:1765 RN50_MAINT_48 (1/2)

    Descriptive name

    HS-DSCH and E-DCH success rate decreased after Blind IFHO activation.

    Applicable controllerscRNC, mcRNC, I-HSPA Adapter

    Modifiable

    YES

    DescriptionWhen Blind IFHO is activated, it requires changing of the intra-frequency measurement quantity needs from EcNo to RSCP. It is defined with RACHIntraFreqMesQuant parameter. After this, the

    initial power calculation anymore.

    With this parameter the values of the RSCP0and BackgroundEcNo can be defined. Additionally, they can be defined if the RSCP is used to calculate EcNo.

  • 8/12/2019 PRfiles Related to MBLB_BLHO

    6/6