product data sheet february 2015 sd 3100-0e05 damcos dphs ... · february 2015 damcos dphs, phs and...
TRANSCRIPT
Product Data SheetJune 2020
SD 3100-0E07
Damcos™ DPHS, PHS and P3Accessories for Valve/Actuator Area
DPHS
PHS
P3
Damcos™ DPHS, PHS and P3 June 2020
2
Unit Description Typical Application
PHS Pipe Block Block with single quick connection and stop valve. The block has connection tread G3/8” or G1/4”.
For emergency operation of 1-line actua-tors (spring return) by means of portable hand pump. The block is pipe mounted.
P3 Cross-Over Plate Plate for cross - connecting ports P and A, respectively B and T of a Cetop-3/NG 6 stack.
Whenever a Cetop-3/NG 6 mounting block is used for mounting of control equipment on the actuator, a P3 plate is necessary to close the Cetop-3 “sand-wich”.
PHS Bleeder Fail Close, submerged Bleed pipe from actuator can be con-nected to block.
For emergency operation of 1-line sub-merged actuator (fail close) by means of portable hand pump. The block is pipe mounted.
PHS Bleeder Fail Open, submerged Bleed pipe from actuator can be con-nected to block.
For emergency operation of 1-line sub-merged actuator (fail open) by means of portable hand pump. The block is pipe mounted.
DPHS Pipe Block, submerged For emergency operation of 2-line actua-tor by means of portable hand pump. The block is pipe mounted.
For emergency operation of 2-line actua-tor or system consisting LPU, both S and D, by means of portable hand pump.
DPHS Flushing Block for Manifold Used for shutting off connections to manifold when flushing or connecting and operating actuators by portable hand pump from outside the deck-box. The block has connection tread G3/8” (G1/4” in manifolds).Two versions one for brass manifold and one for acid proof manifold.Installation requirements: Damcos Brass manifold or acid proof manifold 75 mm pitch only.
For use of shutting off connection to manifold when flushing, connecting and operating actuators by portable hand pump from outside the deck-box.
DescriptionThe following accessories for valve and actuator area are available for typical applications as described below.
643
533
2014,5
6912
49
1130
1324
38
18
PHS-Block G1/4"
G3/8” G1/4”
49
14
26
60
4071
,5
1138
1640
1138
14
30
41,5
7,5
PHS-Block with bleeder, Fail Close
4927
14
26
60
4071
,5
30
41,5
7,511
38
1640
PHS-bleeder fail open
49
14
26
60
4071
,5
7,541,5
3060
1640
1138
1138
DPHS-Block
Damcos™ DPHS, PHS and P3June 2020
3
Technical Specification
PHS PHSPHS - bleed
fail closePHS - bleed
fail openDPHS
pipe block
DPHS* flushing block
Brass / SS
Maximum operation pressure 135 bar/2000 PSI
Maximum test pressure 225 bar/3250 PSI
Flow rate at 100 bar (50 cSt visc.) l/min
6 20 6 6 6 7/5
Temperature range -20°C to +80°C
Weight approx. kg/lb 0.6 / 1.3 0.2 / 0.4 1.1 / 2.4 1.1 / 2.4 1.1 / 2.4 1.6 / 3.5
Seals NBR
HousingMS 58 or AISI 316L
MS 58 MS 58 MS 58 MS 58 MS 58 / AISI 316L
Screws None None None None None MS 58 / AISI 316L
Quick connectionMS 58 or AISI 316L
MS 58 MS 58 MS 58 MS 58 MS 58 / AISI 316L
*) Versions made for 60 bar is good for burst pressure 445 bar!
Hydraulic Diagram
PHS Block
Damcos™ DPHS, PHS and P3 June 2020
4
Hydraulic Diagram
PHS Block with a Bleeder for Fail Close
PHS Block with a Bleeder for Fail Ppen
Damcos™ DPHS, PHS and P3June 2020
5
DPHS Flushing Block for Manifold
Damcos™ DPHS, PHS and P3 June 2020
6
Hydraulic Diagram
PHS
PHS Pipe Block G3/8” PHS Pipe Block G1/4”
PHS Bleeder Fail Open PHS Bleeder Fail Close
Damcos™ DPHS, PHS and P3June 2020
7
P3 DPHS Pipe Block
DPHS Mounting on Manifold
Product Data SheetJune 2020
Damcos™ DPHS, PHS and P3SD 3100-0E07
©2020 Emerson. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Damcos and the Damcos logotype are trademarks of Damcos A/S. Damcos is a member of the Emerson family of companies. All other marks are the property of their respective owners.
The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. Standard Terms and Conditions of Sale can be issued by contacting Damcos A/S. We reserve the right to modify or improve the designs and specifications of our products at any time without notice. Damcos A/S accepts no responsibility for any errors that may appear in this publication.
Emerson Automation SolutionsDamcos A/S Aaderupvej 41 DK-4700 Naestved T +45 5578 7200 F +45 5578 7272
www.Emerson.com/marine