8
PRODUCT DATA SHEET Sika® AnchorFix-2 SUPER STRENGTH, TWO COMPONENT ADHESIVE ANCHORING SYSTEM PRODUCT DESCRIPTION Sika® AnchorFix-2 adhesive anchor system is solvent/styrene free, epoxy acrylate based, and has been specifically formulated as a high performance, two component adhesive anchor system for threaded bars in uncracked concrete. USES Sika® AnchorFix-2 may only be used by experienced professionals. As a fast curing anchoring adhesive for all grades of: Rebars / reinforcing steel Threaded rods Bolts and special fastening systems In the following substrates: Concrete Solid masonry Steel Hard natural stone * Solid rock * * These substrates may vary greatly, in particular with regard to strength, composition and porosity. Therefore, for each application the suitability of Sika® AnchorFix-2 Adhesive must be tested by first applying the Product only to a sample area. Check in particular bond strength, surface staining and discoloration. CHARACTERISTICS / ADVANTAGES Fast curing Standard guns can be used High load capacity Drinking Water certified Non-sag, even overhead Styrene-free epoxy acrylate Low wastage Fixing close to free edges. Versatile range of embedment depths. Anchoring without expansion forces. APPROVALS / STANDARDS EESR to AC308 by ICC-ES PENDING. ESR to AC308 by IAPMO-UES. Certified to ANSI / NSF - 61 by UL. PRODUCT INFORMATION Packaging 10 fl.oz. (299 ml) cartridge Shelf Life 12 months from date of production All Sika® AnchorFix-2 cartridges have the expiry date printed on the label. Storage Conditions Cartridges should be stored in their original packaging, the correct way up, in cool conditions 41 °F to 77 °F (5 °C to 25 °C) out of direct sunlight. Product Data Sheet Sika® AnchorFix-2 November 2018, Version 01.03 020205010020000001 1 / 8

Upload: others

Post on 24-Jan-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRODUCT DATA SHEET Sika® AnchorFix-2 · 2020-01-07 · *The design professional on the job is ultimately responsible for the interpretation of the data provided above. APPLICATION

PRODUCT DATA SHEETSika® AnchorFix-2SUPER STRENGTH, TWO COMPONENT ADHESIVE ANCHORING SYSTEM

PRODUCT DESCRIPTIONSika® AnchorFix-2 adhesive anchor system issolvent/styrene free, epoxy acrylate based, and has beenspecifically formulated as a high performance, twocomponent adhesive anchor system for threaded bars inuncracked concrete.

USESSika® AnchorFix-2 may only be used by experiencedprofessionals.As a fast curing anchoring adhesive for all grades of:

Rebars / reinforcing steel▪Threaded rods▪Bolts and special fastening systems▪

In the following substrates:Concrete▪Solid masonry▪Steel▪Hard natural stone*▪Solid rock*▪

* These substrates may vary greatly, in particular with regard to strength,composition and porosity. Therefore, for each application the suitability of Sika®AnchorFix-2 Adhesive must be tested by first applying the Product only to asample area. Check in particular bond strength, surface staining anddiscoloration.

CHARACTERISTICS / ADVANTAGESFast curing▪Standard guns can be used▪High load capacity▪Drinking Water certified▪Non-sag, even overhead▪Styrene-free epoxy acrylate▪Low wastage▪Fixing close to free edges.▪Versatile range of embedment depths.▪Anchoring without expansion forces.▪

APPROVALS / STANDARDSEESR to AC308 by ICC-ES PENDING.▪ESR to AC308 by IAPMO-UES.▪Certified to ANSI / NSF - 61 by UL.▪

PRODUCT INFORMATIONPackaging 10 fl.oz. (299 ml) cartridge

Shelf Life 12 months from date of productionAll Sika® AnchorFix-2 cartridges have the expiry date printed on the label.

Storage Conditions Cartridges should be stored in their original packaging, the correct way up, incool conditions 41 °F to 77 °F (5 °C to 25 °C) out of direct sunlight.

Product Data SheetSika® AnchorFix-2November 2018, Version 01.03020205010020000001

1 / 8

Page 2: PRODUCT DATA SHEET Sika® AnchorFix-2 · 2020-01-07 · *The design professional on the job is ultimately responsible for the interpretation of the data provided above. APPLICATION

TECHNICAL INFORMATIONTensile Adhesion Strength

The above values represent mean ultimate values and allowable working loads. The allowable working loadshave been reduced using a safety factor of 4.0 for tension and 3.0 for shear, however, in some cases, such aslife safety, safety factors of 10.0 or higher may be necessary.

1.

Allowable loads must be checked against steel capacity. The lowest value controls.2.Tabulated data is applicable to single anchors in normal weight concrete unaffected by edge or spacingreduction factors. Values are valid for anchors installed into dry concrete in holes drilled with a hammer drilland ANSI carbide drill bit.

3.

Service temperatures should remain approximately constant. The maximum long term temperature being122 °F and the maximum short term temperature being 176 °F. Short term temperatures are those thatoccur over brief intervals, for example, diurnal cycling.

4.

Linear interpolation is allowed.5.

*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Service Temperature Long term 40 °F (4 °C) min. / 122 °F(50 °C) max.

Short term (1–2 hours) 176 °F (80 °C)

(ETAG 001, Part 5)

Product Data SheetSika® AnchorFix-2November 2018, Version 01.03020205010020000001

2 / 8

Page 3: PRODUCT DATA SHEET Sika® AnchorFix-2 · 2020-01-07 · *The design professional on the job is ultimately responsible for the interpretation of the data provided above. APPLICATION

Design Considerations

Allowable Tension, Nall = 0.33 x fu x nominal cross sectional areaAllowable Shear, Vall = 0.17 x fu x nominal cross section area*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Tension = 0.33 x fu x nominal cross sectional areaShear = 0.17 x fu x nominal cross section area*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Product Data SheetSika® AnchorFix-2November 2018, Version 01.03020205010020000001

3 / 8

Page 4: PRODUCT DATA SHEET Sika® AnchorFix-2 · 2020-01-07 · *The design professional on the job is ultimately responsible for the interpretation of the data provided above. APPLICATION

SYSTEM INFORMATIONSystem Structure

*The design professional on the job is ultimately responsible for the interpretation of the data provided above.

APPLICATION INFORMATIONMixing Ratio Component A : component B = 10 : 1 by volume

Coverage

*Number of fixings assumes 30ml wastage in initial extrusion and holes filled to 3/4 full

Product Data SheetSika® AnchorFix-2November 2018, Version 01.03020205010020000001

4 / 8

Page 5: PRODUCT DATA SHEET Sika® AnchorFix-2 · 2020-01-07 · *The design professional on the job is ultimately responsible for the interpretation of the data provided above. APPLICATION

Sag Flow Non-sag, even overhead

Product Temperature Sika® AnchorFix-2 must be at a temperature of between 41 °F (5 °C) to 68 °F(20 °C) for application.

Dew Point Beware of condensation.▪Beware of frost.▪

Open Time Working & Loading TimesCartridgeTemperature

T Work (minutes) Base MaterialTemperature

T Load (hours)

Minimum 41°F - 14 °F to 32 °F* 24 hoursMinimum 41 °F - 32 °F to 41°F 180 minutes41 °F to 50 °F 8 41 °F to 50 °F 100 minutes50 °F to 68 °F 4 50 °F to 68 °F 70 minutes68 °F to 77 °F 3 68 °F to 77 °F 40 minutes77 °F to 86 °F 2 77 °F to 86 °F 40 minutes86 °F 1 86 °F 40 minutesT Work is the typical time to gel at the highest temperature in the rangeT Load is the typical time to reach full capacity* The design professional on the job is ultimately responsible for the interpretation of the data provided above.

Product Data SheetSika® AnchorFix-2November 2018, Version 01.03020205010020000001

5 / 8

Page 6: PRODUCT DATA SHEET Sika® AnchorFix-2 · 2020-01-07 · *The design professional on the job is ultimately responsible for the interpretation of the data provided above. APPLICATION

APPLICATION INSTRUCTIONSSUBSTRATE QUALITY

Mortar and concrete must be older than 28 days.Substrate strength (concrete, masonry, natural stone)must be verified. Pull-out tests must be carried out if thesubstrate strength is unknown. The anchor hole mustalways be clean, dry, free from oil and grease etc. Looseparticles must be removed from the holes.Threaded rods and rebars have to be cleaned thoroughlyfrom any oil, grease or any other substances andparticles such as dirt etc.

MIXING

Getting the cartridge ready1. Unscrew the cap

2. Cut the film

3. Screw on the static mix-er

4. Place the cartridge intothe gun and start applica-tion

When the work is interrupted the static mixer canremain on the cartridge after the gun pressure has beenrelieved. If the resin has hardened in the nozzle whenwork is resumed, a new nozzle must be attached.

Product Data SheetSika® AnchorFix-2November 2018, Version 01.03020205010020000001

6 / 8

Page 7: PRODUCT DATA SHEET Sika® AnchorFix-2 · 2020-01-07 · *The design professional on the job is ultimately responsible for the interpretation of the data provided above. APPLICATION

APPLICATION METHOD / TOOLS

Anchors in solid masonry/concrete:Drilling of hole with anelectric drill to the diamet-er and depth required.Drill hole diameter mustbe in accordance with an-chor size.

The drill hole must becleaned with a blow pumpor by compressed air,starting from the bottomof the hole. (at least 2×)Important: use oil-freecompressors.

The drill hole must bethoroughly cleaned withthe special steel brush(brush at least 2×). Thediameter of the brushmust be larger than thediameter of the drill hole.

The drill hole must becleaned with a blow pumpor by compressed air,starting from the bottomof the hole (at least 2×).Important: use oil-freecompressors.

The drill hole must bethoroughly cleaned withthe special steel brush(brush at least 2×). Thediameter of the brushmust be larger than thediameter of the drill hole.

The drill hole must becleaned with a blow pumpor by compressed air,starting from the bottomof the hole (at least 2×).Important: use oil-freecompressors.

Pump approx. twice untilboth parts come out uni-formly. Do not use this ma-terial. Release the gunpressure and clean thecartridge opening with acloth.

Inject the adhesive intothe hole, starting from thebottom, while slowlydrawing back the staticmixer.In any case avoid en-trapping air. For deepholes extension tubing canbe used.

Insert the anchor with arotary motion into thefilled drill hole. Some ad-hesive must come out ofthe hole.Important: the anchormust be placed within theopen time.

During the resin harden-ing time the anchor mustnot be moved or loaded.Wash tools immediatelywith Sika® Colma Cleaner.Wash hands and skin thor-oughly with warm soapwater.

CLEANING OF TOOLS

Tools must be cleaned as soon as possible with a cleanrag.

Product Data SheetSika® AnchorFix-2November 2018, Version 01.03020205010020000001

7 / 8

Page 8: PRODUCT DATA SHEET Sika® AnchorFix-2 · 2020-01-07 · *The design professional on the job is ultimately responsible for the interpretation of the data provided above. APPLICATION

BASIS OF PRODUCT DATAResults may differ based upon statistical variationsdepending upon mixing methods and equipment,temperature, application methods, test methods, actualsite conditions and curing conditions.

OTHER RESTRICTIONSSee Legal Disclaimer.

ENVIRONMENTAL, HEALTH AND SAFETYFor further information and advice regardingtransportation, handling, storage and disposal ofchemical products, user should refer to the actual SafetyData Sheets containing physical, environmental,toxicological and other safety related data. User mustread the current actual Safety Data Sheets before usingany products. In case of an emergency, call CHEMTRECat 1-800-424-9300, International 703-527-3887.

LEGAL DISCLAIMER• KEEP CONTAINER TIGHTLY CLOSED• KEEP OUT OF REACH OF CHILDREN• NOT FOR INTERNAL CONSUMPTION• FOR INDUSTRIAL USE ONLY• FOR PROFESSIONAL USE ONLY

Prior to each use of any product of Sika Corporation, itssubsidiaries or affiliates (“SIKA”), the user must alwaysread and follow the warnings and instructions on theproduct’s most current product label, Product DataSheet and Safety Data Sheet which are available atusa.sika.com or by calling SIKA’s Technical ServiceDepartment at 1-800-933-7452. Nothing contained inany SIKA literature or materials relieves the user of theobligation to read and follow the warnings andinstructions for each SIKA product as set forth in thecurrent product label, Product Data Sheet and SafetyData Sheet prior to use of the SIKA product.

SIKA warrants this product for one year from date ofinstallation to be free from manufacturing defects and tomeet the technical properties on the current ProductData Sheet if used as directed within the product’s shelflife. User determines suitability of product for intendeduse and assumes all risks. User’s and/or buyer’s soleremedy shall be limited to the purchase price orreplacement of this product exclusive of any labor costs.NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALLAPPLY INCLUDING ANY WARRANTY OFMERCHANTABILITY OR FITNESS FOR A PARTICULARPURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANYLEGAL THEORY FOR SPECIAL OR CONSEQUENTIALDAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THEUSE OF THIS PRODUCT IN A MANNER TO INFRINGE ONANY PATENT OR ANY OTHER INTELLECTUAL PROPERTYRIGHTS HELD BY OTHERS.

Sale of SIKA products are subject to the Terms andConditions of Sale which are available athttps://usa.sika.com/en/group/SikaCorp/termsandconditions.html or by calling 1-800-933-7452.

SikaAnchorFix-2-en-US-(11-2018)-1-3.pdf

Sika Corporation201 Polito AvenueLyndhurst, NJ 07071Phone: +1-800-933-7452Fax: +1-201-933-6225usa.sika.com

Sika Mexicana S.A. de C.V.Carretera Libre Celaya Km. 8.5Fracc. Industrial BalvaneraCorregidora, QueretaroC.P. 76920Phone: 52 442 2385800Fax: 52 442 2250537

Product Data SheetSika® AnchorFix-2November 2018, Version 01.03020205010020000001

8 / 8