Staco Energy Products Co.

Welcome

Who is Staco Energy Products Company ?

Page 2: Product: UPS: FirstLine P

Staco Energy Products Co.

• Who are we?– A 75+ year old privately held manufacturer of voltage control and power quality products. Based in Dayton Ohio with 80 employees.

• What do we do??– We provide tailored power solutions to targeted

markets.

Page 3: Product: UPS: FirstLine P

Staco Energy Products Co.

• How do we do it? – We partner with the best in every market

• Rep’s, Distributors, Integrators, OEM’s– We focus on specific vertical applications / markets

• WWT, Education, High Energy Physics, Process Manufacturing– We provide world class service and support

• Over 60 Factory trained service tech’s in the US. – We manufacture the best products on the market

• We back our products with the best warranties in the industry

Page 4: Product: UPS: FirstLine P

Staco Energy Products Co.

65kVA / 58.5kW80kVA / 72kW100kVA / 90kW125kVA / 112.5kW160kVA / 144kw200kVA / 180kw250kVA / 225kw

Page 5: Product: UPS: FirstLine P

FirstLine P UPS

• True double conversion, “On-Line”• Hot Swap Unit Capability• Digital Signal Process Control• Menu Selectable Monitoring Panel with Graphic display• Parallel up to 8 Modules• Dual Bus Configurations• Delayed Start Up on power source return• IGBT, PWM Inverter (Insulated Gate Bipolar Transistor) • Efficiency up to 98%• 0.99 High Input Power Factor• Configurable Power Walk-In• Sinusoidal Output Waveform

Page 6: Product: UPS: FirstLine P

Major Components

• Rectifier complete with power factor correction• Fast Battery charger • Continuous duty rated Static Switch• Manual Maintenance Bypass• Input Isolation switch (SWIN)• Output Isolation switch (SWOUT)• Maintenance Isolation switch (SWMB)• Bypass Isolation switch (SWBY)• Parallel Kit (Standard)• 4 x 2 and 2 x 2 Voltage Configuration available

Page 7: Product: UPS: FirstLine P

AC Input Characteristics

Nominal Voltage: 480 VAC, 3 Phase, 4-wire (plus ground) or 208Y/120 VAC, 3 Phase, 4-wire + ground with external line up and match transformer cabinet (Optional)Nominal Voltage Range: +15/-10% from nominal voltage during battery recharge.Voltage Range on battery: +15% / -40%Frequency Range: 45 - 65 Hz)Power Factor: > 0.99 at full load, nominal conditions.Current Harmonic Distortion (THDi): < 3%Inrush current: Less than nominal input current for less than one cycle.Input Surge Protection: UPS shall be equipped to withstand surges per ANSI/IEEE C62.41.Rectifier Walk-in: Progressive from 0 to 30 seconds (adjustable).Rectifier Walk-in Delay Timer: Progressive start of rectifier from 0 to 120 seconds (adjustable).

Page 8: Product: UPS: FirstLine P

AC Output Characteristics

Voltage: 480Y/277 VAC, ± 1% steady state variation phase-to-phase voltage volts AC, three-phase, 4 wire plus ground (Standard Voltage) or 208Y/120 VAC, 3 Phase, 4-wire + ground - with external line up and match transformer cabinet (Optional).Frequency: 60Hz, + 2%, 60Hz, + .05% when free running.Voltage regulation: ±1% for balanced load, ±3% for 100% unbalanced load.Voltage Distortion: Maximum 2% total (THD).Voltage Transient (Step Load) Response: + 5% for 100% step load change.Voltage Recovery Time: Return to within 1% of nominal value within 20 milliseconds.Phase Angle Displacement: 120 degrees + 1 degree for balanced load; 120 degrees, + 1 degree for 100% unbalanced load.Non-Linear Load Capability: Output voltage total harmonic distortion shall be less than 2% when connected to a 100% non-linear load with a crest factor not to exceed 3%.

Page 9: Product: UPS: FirstLine P

AC Output Characteristics (continued)

Slew Rate: 1 hertz/second maximum.Power Factor: 0.9 at the rated volt amperes .Inverter Overload Capability: 110% of rated load for 60 minutes, 150% of rated load for 1 minute.Bypass Overload Capability: 110% for 60 minutes, 125% for 10 minutes,150% for 1 minute.Output Waveform: SinusoidalEfficiency: (DC-AC): Minimum - 95% at Full Load, (AC-AC): Minimum – 93% at Full Load

Page 10: Product: UPS: FirstLine P

Cabinet Configuration

A. Control panel with graphic displayB. Door handleC. Ventilation grillesD. Communication areaE. Front Cover panel with ventilation grillesF. Switch cover panelG. Door

1. SWIN: Input isolating switch2. SWOUT: Output isolating switch 3. SWMB: Maintenance isolating switch 4. WBY: Bypass isolating switch

A

B

D

C

E

1

2

3

4

G

G

F

Page 11: Product: UPS: FirstLine P

Card Locations

A

F G

EDB

C

J

N

H

I

K

A. Parallel CardB. EPO ControlC. Remote Commands and AlarmsD. RS-232-2E. RS-232-1F. Slot 2 (Aux)G. Slot 1 (Main)H. Remote Alarm Dry Contact Card 1 (Optional)I. Remote Alarm Dry Contact Card 2 (Optional)J. Multi I/O Card (Optional)K. Interface Terminal ConnectorL. UGS (Optional)

Page 12: Product: UPS: FirstLine P

Bottom Cable Entry (Standard)

Power Battery Cable Entry

External Control Cable Entry

Power AC Cable Entry

REAR

FRONT

UPS Bottom View

Page 13: Product: UPS: FirstLine P

Air Flow (Forced & Convection)

The heat dissipation needed for the correct operation of the UPS is brought about by the air current made by the fans located inside the UPS (forced convection) and by the air around the side panels (natural convection).

Clearance: FRONT and at least one of the three side walls free: right, left or back.

Page 14: Product: UPS: FirstLine P

Control Panel Display

Page 15: Product: UPS: FirstLine P

Control Panel

Page 16: Product: UPS: FirstLine P

Menus

Page 17: Product: UPS: FirstLine P

Basic Control Functions

• Output Voltage – Selects the rated output voltage

• Operating Mode – Selects the operating Mode: On-Line, Stand-By ON, Smart Active

• Auto Off – If bypass line is present and the load is < of the set value than the load will be supplied from the bypass line. If the bypass line in not preset and the load is < of the set value than the load will not be supply (configurable 0 to 99%).

• Battery Low Warning – Estimated battery time remaining for low battery warning (configurable).

• Battery Capacity – Sets the Amp Hour Battery installed.

• Audible Alarm – Audible alarm operating mode: Enable/Disable

• Language Select area – English, Italian, German, French, Spanish, Polish or Turkish.

Page 18: Product: UPS: FirstLine P

Advanced Control Functions

• Input Frequency Tolerance Range – Selects the acceptable range for the input frequency for switching to the bypass and for the synchronization of the output: +/- 1 to +/- 6 in 1% stages.

• Bypass Voltage Thresholds – Selects the acceptable voltage range for switching to the bypass: +/- 5 to +/- 25 in 1% stages.

• Bypass Voltage Threshold for ECO – Selects the acceptable voltage range for operation in ECO Mode: +/- 5 to +/- 25 in 1% stages.

• Switch-On Delay – Waiting time for automatic power-on after the return of power source voltage: Disable or configurable 1 to 255 in 1 second stages.

• Power Walk-In – Activates the gradual return to power source mode: Activated or Deactivate

• Power walk-In Duration – Sets the duration of the gradual return to power source voltage (only if Power Walk-In is activated: Minimum 0 seconds to maximum 125 seconds in 1 second stages.

• Inverter Synchronization Speed to Bypass Line – Selects the synchronization speed of the inverter to the bypass line: 0.1 to 1 Hz/sec (parallel units), 0.1 to 3 Hz/sec (single units).

Page 19: Product: UPS: FirstLine P

Alarms

Normal Operation

Disturbances on Bypass Line

Manual Bypass (SWMB) On

Bypass Line Volt, Failure

Main Line Voltage Failure

Pre-alarm, Low Battery Voltage

Low Battery Charge or Closed Disconnect

Low Input Voltage

Output Overload

Internal Fault

Temporary Bypass, Wait

Bypass for Output Overload

Bypass Command ON or OFF

Remote Bypass Command Active

Over-temperature or Fan Failure

Input Voltage Sequence not OK

Output Off

System Off Command ON or OFF

Remote System Command ON or OFF

Auto-shutdown Timer ON

System Off

Battery test ON

Parallel Cable Fault

Fuse Fault

Battery Discharge Fail

High Battery Temperature

Slave UPS OFF

Fan Fault

Parallel Redundant Lost: High Unit Power

Parallel Redundant Lost: Unit OFF

Break Circuit Fail

Break Circuit Overload

Rectifier Switched Off by Remote Command

UPS Service Required

Battery Service Required

Input Switch Off

Insulation Loss-AC

Insulation Loss-DC

Over-temperature On Bypass Line Transfer

Inverters Off

Page 20: Product: UPS: FirstLine P

FirstLine P 65 – 125kVA UPS Models

Model Number DescriptionDimensionsH” x W” x D”

 Weight.(lbs.)

480V x 480V      

FLU-065-0065kVA /58.5kW 480V/480Y/277,

50/60Hz75 x 31.5 x 33.5 1,499

FLU-080-0080kVA /72kW

480V/480Y/277, 50/60Hz

75 x 31.5 x 33.5 1,499

FLU-100-00100kVA /90kW, 480V/480Y/277,

50/60Hz75 x 31.5 x 33.5 1,609

FLU-125-00125kVA /112.5kW, 480V/480Y/277,

50/60Hz75 x 31.5 x 33.5 1,742

Page 21: Product: UPS: FirstLine P

FirstLine P 160 – 250kVA UPS Models

Model Number Description

DimensionsH” x W” x D”

 Weight.(lbs.)

480V x 480V      

FLU-160-00160kVA /144kW,

480V/480Y/277, 50/60Hz 75 x 39.5 x 33.5 1,984

FLU-160-T160kVA /144kW,

480V/480Y/277, 50/60Hz w/ Internal Bypass

75 x 55 x 33.5 2,326

FLU-200-00200kVA /180kW,

480V/480Y/277, 50/60Hz 75 x 39.5 x 33.5 2,205

FLU-200-T200kVA /180kW,

480V/480Y/277, 50/60Hz w/ Internal Bypass

75 x 55 x 33.5 2,546

FLU-250-00250kVA /225kW,

480V/480Y/277, 50/60Hz 75 x 39.5 x 33.5 2,425

FLU-250-T250kVA /225kW,

480V/480Y/277, 50/60Hz w/ Internal Bypass

75 x 55 x 33.5 2,767

Page 22: Product: UPS: FirstLine P

FirstLine P Application Notes

1. The FLU-160-00, FLU-200-00 & FLU-250-00 units DO NOT have an internal bypass. If specification requires internal bypass the -T Model MUST be used.

2. In all cases, if the specification requires an internal and external bypass you MUST use the -T Model plus the Line Up & Match

bypass cabinet.

Page 23: Product: UPS: FirstLine P

UPS Cabinet 65 – 125kVA

Page 24: Product: UPS: FirstLine P

UPS Cabinet 160 – 250kVA w/o Bypass

Page 25: Product: UPS: FirstLine P

UPS Cabinet 160 – 250kVA with Bypass

Page 26: Product: UPS: FirstLine P

UPS Cabinet - Internal

Page 27: Product: UPS: FirstLine P

FirstLine P with Battery Cabinet

The UPS uses a valve-regulated sealed lead acid (VRLA) heavy duty industrial battery, designed for auxiliary power service in a UPS application. The primary battery is furnished with impact-resistant plastic cases and housed in a matching cabinet(s) next to the UPS. The UPS is capable of utilizing Wet Cell & NiCad batteries.

Protection Against Deep Discharge and Self-Discharge: The UPS is equipped with a device designed to protect the battery against deep discharge, depending on discharge conditions, with isolation of the battery by a circuit breaker. From the monitoring panel you can adjust the battery shutdown voltage as a function of a discharge coefficient to avoid excessive discharge at less than the rated output. A second device helps avoid self-discharge of the battery into the UPS control circuits during an extended shutdown of the UPS (over two hours).Battery Self-Tests: 1. The battery monitoring system performs the following automatic functions:

• Battery circuit check, programmable 9-99 days. • Partial discharge test every three months.

Page 28: Product: UPS: FirstLine P

Standard External Battery Models

Model Number Voltage#

CabinetsInternal Strings

NumberBatteries

DimensionsH” x W” x D”

Weight(lbs.)

FLU-BAT-200-1-480-B 480 1 1 40 75 x 26.3 x 38 2,307FLU-BAT-200-2-480-B 480 1 2 80 75 x 26.3 x 38 3,932FLU-BAT-300-2-480-B 480 1 2 80 75 x 26.3 x 38 3,923

The FLU-BAT-300-2-480-B is ONLY used with the 100kVA and 125kVA.The FLU-BAT-200-480-1-B can be used with a FLU-BAT-300-2-480-B

Page 29: Product: UPS: FirstLine P

FirstLine P Battery Back Up Times (Minutes)             

65kVA 200W/50AH 1 1 26 14 8 2,100

  1 2 66 39 26 3,700  2 3 107 66 46 5,800  2 4 149 93 66 7,400  3 5 190 121 86 9,500  3 6 229 149 107 11,100  4 7 266 171 128 13,200  4 8 301 204 149 14,800             80kVA 200W/50AH 1 2 38 30 19 3,700

  2 3 84 51 35 5,800  2 4 118 73 51 7,400  3 5 152 95 67 9,500  3 6 185 118 84 11,100  4 7 217 141 101 13,200  4 8 248 163 118 14,800             100kVA 200W/50AH 1 2 38 21 14 3,700

  2 3 64 38 25 5,800  2 4 90 55 38 7,400  3 5 118 73 51 9,500  3 6 145 90 64 11,100  4 7 172 109 77 13,200  4 8 198 127 90 14,800             125kVA 200W/50AH 1 2 30 16 10 3,700

  2 3 51 30 20 5,800  2 4 73 44 30 7,400  3 5 95 58 40 9,500  3 6 118 73 50 11,100  4 7 141 88 62 13,200  4 8 164 103 73 14,800

kVA/Watts/Ah # CABINETS # STRINGS 50% LOAD 75% LOAD 100 % LOAD Weight (lbs.)

Page 30: Product: UPS: FirstLine P

FirstLine P Battery Back Up Times (Minutes)

             

160kVA 200W/50AH 2 3 35 19 12 5,800  2 4 51 30 19 7,400  3 5 67 40 27 9,500  3 6 84 51 35 11,100  4 7 101 61 43 13,200  4 8 118 73 51 14,800             200kVA 200W/50AH 2 3 25 14 8 5,800  2 4 38 21 14 7,400  3 5 51 30 19 9,500  3 6 64 38 25 11,100  4 7 77 46 32 13,200  4 8 90 55 38 14,800             250kVA 200W/50AH 2 4 28 15 9 7,400  3 5 38 21 14 9,500  3 6 48 28 18 11,100  4 7 58 34 23 13,200  4 8 69 41 28 14,800

kVA/Watts/Ah # CABINETS # STRINGS 50% LOAD 75% LOAD 100 % LOAD Weight (lbs.)

Page 31: Product: UPS: FirstLine P

External Battery Cabinet

Page 32: Product: UPS: FirstLine P

Battery Cabinet - Internal

Page 33: Product: UPS: FirstLine P

Standard Battery Characteristics

Standard BatteryValve Regulated Lead Acid (VRLA), Sealed Maintenance Free, CSB HR12200W specifically designed for high efficient discharge applications. Its characteristics are high energy density, small footprint and high discharge efficiency. Rated for more than 260 cycles at 100% discharge, in cycle service, up to 10 years in standby service. .

6 Cells per unit12 volts per unit200 Watt, 50Ah

Battery Voltage: 420 volts DC minimum before cutoff, 540 volts float.

Maximum DC Current: Maximum DC current at cutoff voltage:80kVA -196 amperes ,100kVA – 236 amperes,125kVA – 296 amperes

Page 34: Product: UPS: FirstLine P

FirstLine P 4 x 4 Bypass Models

 Part Number

 kVA

 Voltage

 Description

DimensionsH” x W” x D”

Wt. (lbs.)

            FLU-P-65-MBPS

 65

 480-

480Y/277

3 Breaker External Line Up & Match Maintenance Bypass, Top Cable Entry & Interlocks

 75 x 15.75 x 33.35

 250

 FLU-P-80-MBPS

 80

 480-

480Y/277

3 Breaker External Line Up & Match Maintenance Bypass, Top Cable Entry & Interlocks

 75 x 15.75 x 33.35

 250

 FLU-P-100-MBPS

 100

 480-

480Y/277

3 Breaker External Line Up & Match Maintenance Bypass, Top Cable Entry & Interlocks

 75 x 15.75 x 33.35

 250

 FLU-P-125-MBPS

 125

 480-

480Y/277

3 Breaker External Line Up & Match Maintenance Bypass, Top Cable Entry & Interlocks

 75 x 15.75 x 33.35

 250

 FLU-P-160-MBPS

 160

 480-

480Y/277

3 Breaker External Line Up & Match Maintenance Bypass, Top Cable Entry & Interlocks

75 x 30 x 33.5 350

 FLU-P-200-MBPS

 200

 480-

480Y/277

3 Breaker External Line Up & Match Maintenance Bypass, Top Cable Entry & Interlocks

75 x 30 x 33.5 350

 FLU-P-250-MBPS

 250

 480-

480Y/277

3 Breaker External Line Up & Match Maintenance Bypass, Top Cable Entry & Interlocks

75 x 30 x 33.5 350

Page 35: Product: UPS: FirstLine P

65 – 125kVA 4 x 4 - 3 Breaker MBP Cabinet

Page 36: Product: UPS: FirstLine P

160 – 250kVA 4 x 4 - 3 Breaker MBP Cabinet

Page 37: Product: UPS: FirstLine P

4 x 2 & 2 x 2 Transformer/ Bypass Cabinet

Page 38: Product: UPS: FirstLine P

FirstLine P Top Entry Side Car Model

 Part Number

 kVA

 Voltage

 Description

DimensionsH” x W” x D” Wt. (lbs.)

            FLU-CEC All

 480

Top Cable Entry Side Car, allows for top or side cable entry.

 75 x 15.75 x 33.35

 250

Page 39: Product: UPS: FirstLine P

Top Entry Side Car Cabinet

Page 40: Product: UPS: FirstLine P

FirstLine P 2 x 2 Transformerless PDU

Part Number kVAOutputVoltage Description

DimensionsH” x W” x D”

FLU-PDC-P2 All 208V-208Y/120

Transformerless Line Up & Match Power Distribution (PDU) with (2) 42 Pole, 225 Amp Panelboards, with Mains and type Sq. D NQ442L2. Accepts 1, 2 & 3 Pole Branch Circuit Breakers bolt-on or plug-in.

75 x 22 x 33.35

Page 41: Product: UPS: FirstLine P

Transformerless 2 x 2 PDU Cabinet

Page 42: Product: UPS: FirstLine P

Single or Dual Source Input – No Bypass

Single Input Dual Input

Page 43: Product: UPS: FirstLine P

Single or Dual Source Input w/Bypass

Single Input Dual Input

Page 44: Product: UPS: FirstLine P

2 x 2 Input/Output Transformers w/Bypass

Single Input Dual Input

Page 45: Product: UPS: FirstLine P

208V Output Transformers w/Bypass

Single Input Dual Input

Page 46: Product: UPS: FirstLine P

Paralleled Systems

Page 47: Product: UPS: FirstLine P

Paralleling

The UPS has expansion capabilities for up to 8 modules paralleled for capacity or redundancy as required to support future growth. The UPS units can be connected in parallel and shall share the current and load between them.In a system with several UPS units connected in parallel, there is a single MASTER unit and the remaining units are SLAVE units. The UPS units must be the same rating and the MASTER is chosen on start-up. The MASTER and SLAVE units can exchange roles. If a unit is being serviced, e.g. due to an inverter fault, it will automatically be excluded. The load at this point will be shared between the units that are still active; if the power in output is excessive for the remaining UPSs, the system logic will switch all the units, including the UPS that was excluded, onto the by-pass line.

Page 48: Product: UPS: FirstLine P

Communication Options

PowerShield: Communication Software provides efficient, user-friendly UPS management using bar chart displays to show major operational information such as the input voltage, UPS load % and batteries charge %. The software also provides detailed information on fault conditions and UPS operating characteristics. PowerShield3 has been developed with a client/server architecture that makes it flexible and easy to use, and provides multi-lingual and on-line support.

Operating systems supported include Windows 2000, 2003Server, XP, Vista, 2008 Server, 7, Linux, Novell Netware, Mac OS X and most common UNIX operating systems such as: IBM AIX, HP, SUN Solaris INTEL and SPARC, SCO Uniware and Open Server, Silcon Graphics IRIX, Compaq Tru64 UNIX and DEC UNIX, Open BSD UNIX and FreeBSD UNIX, NCR UMIX, HP Open VMS VMWare ESX and VSPHERE.

Page 49: Product: UPS: FirstLine P

PowerShield

Page 50: Product: UPS: FirstLine P

Communication Options

PowerNETGuard: Supervision software provides centralize UPS management using network interface (SNMP) communications. It is ideal for Data Centre managers and medium to large sized networks. PowerNETGuard uses the RFC1628 standard Management Information Base (MIB) and ensures standardized UPS management wherever they are located.Operating systems supported include Windows (98, ME, NT, 2000, 2003, XP and Vista), Kinux, MacOSX, Solaris 8, 9 and 10 and Silcon Grapics IRIX.

Page 51: Product: UPS: FirstLine P

PowerNETGuard

Page 52: Product: UPS: FirstLine P

Communication Options

Netman Plus: Allows UPS management across a LAN using any of the main network communication protocols - TCP/IP, HTTP and network interface (SNMP). NetMan Plus enabled UPS integrate easily into medium and large sized networks and provide reliable communications between the UPS and management systems employed.

Page 53: Product: UPS: FirstLine P

Netman PLUS (LAN / WAN)

Page 54: Product: UPS: FirstLine P

Netman PLUS (WAN)

Page 55: Product: UPS: FirstLine P

Communication Options

MultiCOM MODBUS/JBUS: Protocol converter used to monitor the UPS using the MODBUS/JBUS protocol on RS232 or RS485 serial lines. It can also manage a second independent RS232 serial line that can be used to connect to other devices such as the Netman or a PC using PowerShield software.

Page 56: Product: UPS: FirstLine P

Communication Options

MultiCOM Serial/USB:

Provide the UPS with an additional RS232 serial interface or USB port. The USB port allows the UPS to communicate with Apple Macintosh computers as well as Windows and Linux operating systems.

Page 57: Product: UPS: FirstLine P

Communication Options

Multi I/O: Protocol converter provides a configurable input and output signal contacts to allow UPS integration with control systems. It can be used to connect two devices to a single UPS serial communication port. It can also communicate using the MODBUS/JBUS protocol on RS485 lines.

Page 58: Product: UPS: FirstLine P

Communication Options

IBM AS/400 Communication Kit: Provides a single-level memory management feature that makes it compulsory for the system to be shutdown in a controlled and orderly manner. Without UPS protection an AS/400 is not protected from mains failures. A momentary loss of power can cause hardware damage, data corruption and a lengthy reboot period.

Page 59: Product: UPS: FirstLine P

Communication Options

I/O Expansion Card: Provides addition remote alarm functions as identified below. The card contains 6 outputs: potential-free contacts for alarms (programmable from the display panel) (and capable of switching up to 30 V AC or DC at UP 1 Amp) , 2 inputs (programmable from the panel) and 1 12V DC maximum 100mA auxiliary input. 2 additional slots shall be available for a total of 12 additional contacts.

•Disturbances on Bypass Line•Manual Bypass ON•Bypass Line Voltage Fail•Main Line Voltage Fail•Pre-alarm , Low Battery Voltage•Low Input Voltage •Output Overload•Internal Fault•Bypass for Output Overload•Over Temperature or Fan Failure•Input Voltage Sequence OK•Output OFF

Page 60: Product: UPS: FirstLine P

Environmental Sensor Option

Netman Environmental Sensor: Monitors and record environmental conditions as well as activities in protected areas and at the premises where the UPS is installed. Environmental sensors monitor and record environmental conditions and activities within a designated building area. The sensors provide extensive management and control, triggering cooling fans and locks in response to changes in temperature and humidity. Remote monitoring and control can be provided via the internet, SNMP and PowerShield software. NetMan Plus can support up to 6 separate sensors. The environmental sensors are easy to install and do not need a separate external power supply.

Page 61: Product: UPS: FirstLine P

Remote Monitor Panel Option

MultiPanel - Remote Monitoring Panel: Provides a detailed UPS status overview in real time. It is compatible with all FirstLine P UPS’s and can display values for UPS specific input and output supplies, and battery set measurements. MultiPanel has a high-definition graphical display and can report in 7 languages: English, Italian, German, French, Spanish, Russian and Chinese.3 independent serial ports are provided, one which allows for UPS monitoring via the MODBUS/JBUS protocol (on either an RS485 or RS232 serial line). The others can be used with devices such as the Netman Plus or a PC running PowerShield software.

Page 62: Product: UPS: FirstLine P

Other Options

Seismic Bracing & Withstand CertificationSite specific Seismic Bracing for Zone A-F with certification and drawings available.

Top or Side Cable EntryStandard cable entry is from the bottom with availability for top or side incoming entry.

Harsh Environment EnclosureThe UPS and any accessory cabinet(s) are capability of being mounted and completely wired internal to, include AC cooling, inside any NEMA type enclosure (NEMA 12, 3R, 4X) by the manufacturer.

Spare PartsAvailable in three levels - Minor, Moderate and

Major Service Agreements

Multi level service and maintenance agreements available.

Page 63: Product: UPS: FirstLine P

An Engineers Comment:

“ I recently I had the pleasure to specify and install the Staco FirstLIne P UPS at one of my high-profile customers . Having been in sales & service of UPS systems since 1977, it is rare that a real "gem" comes along! When it comes to a UPS--I would consider this as a gem.”

Demps E. Bannerman, PhD., E.E.

Page 64: Product: UPS: FirstLine P

Service

Services Tailored to our customers needs Five levels of service

System startup to full on site support Local factory trained Technicians Spare parts kits, batteries monitoring and

replacement, site power quality survey, infrared thermo scan and more.

ID

AZ

UT

MT

CO

AL

FL

SC

TN

KY

INOH

NC

SD

KS

NE

MN

WI

IA

IL

MO

AR

MS

OK

ND

OR

CA NV

WA

AK

PA

ME

VA

NY CT

WVMD

NJ

VT

NHMA

DE

RI

HI

LA

MI

GA

TX

South-Central Region

South East Region

Mid Atlantic Region

Rocky Mount Region

Midwest Region

North East Region

Territory Manager Regional Team Leader

Field Service Tech

07/26/08 D. Crocker

Western Territory Eastern Territory

CGS Reqs

Central Territory

Eastern Dispatcher 8am-5pm EST

Central Dispatcher 7am-4pm EST

Western Dispatcher 10am-7pm EST

WY

NM

West Coast RegionRegional TSS

Page 65: Product: UPS: FirstLine P

Start Up Check List:

PURPOSE: Work to cover during startup of all models of First Line Uninterruptible Power Supplies.

INSTRUCTIONS: Check for physical damage to the system cabinets. Verify that all shipping covers, inserts, and brackets are removed as specified in the

User’s Handbook. Verify that the UPS is installed in a clean, temperature controlled area, and the

environment meets all criteria in the User’s Manual. Verify all internal connections and components are in the proper place and secure. Survey physical location of the system. (Accessibility, lighting, cleanliness, ventilation Survey additional customer equipment being present (TVSS, Generator, Motors,

Capacitors, and Transformers). Survey electrical Installation of UPS regarding wire size and circuit protection.• Dual Source connections: In equipment’s with separate bypass line, an isolation

transformer must be placed at any of both input power supply mains of the UPS (rectifier input or static bypass), in order to avoid the direct connection of the neutral of both mains through the internal wiring of the equipment. This is only applicable power supply comes from two different electrical mains, as for example: - Two different electrical companies. - One electrical company and a generator set, ...

Page 66: Product: UPS: FirstLine P

Staco Energy Products Co.

Questions?