    OCCUPATIONAL HEALTH & SAFETY ASSESSMENT.

    Terms Used: -

    1. HAZARD : Potential to cause injury, damage to Environment,Health and Property.

    2. RISK : combination of the likelihood and Consequences of a

    specified Hazardous event occurring.

    3. LOSS : It is an avoidable waste of any resource.

    4 INCIDENT : It is an event giving rise to an accident or had thepotential to lead to an accident.

    5. NEAR MISS : An unattended occurrence which may not result in an

    Injury or Damage (eg. Elec. Shock, Gas leak, Oil

    Spill, Process upset.)

    6. ACCIDENT : It is an undesired event-giving rise to death, ill health,

    injury,Damage or any other loses.

    7. SAFETY : It is about managing the risk and to control the

    accidental risk.

    8. OH & S RISK MANAGEMENT:

    The essence of the Risk Management is to avoid

    High Risks, Manage Medium Risks and Live with

    Low Risks.

    2

  • 8/14/2019 Project on Fire

    3/30

    OCCUPATIONAL HEALTH HAZARDS:

    CHEMICALS:

    Dust / Fiber.

    Smoke.

    Aerosols.

    Gases / Vapors.

    PHYSICAL:

    Noise.

    Vibration.

    Pressure.

    Temperature.

    Radiation.

    Illumination.

    BIOLOGICAL:

    Virus.

    Bacteria.

    Fungi.

    ERGONOMIC:

    Lifting.

    Repetitive motion.

    Monotony.

    Fatigue.

    3

  • 8/14/2019 Project on Fire

    4/30

    OCCUPATIONAL HEALTH & SAFETY ASSESSMENT:

    Will help the Organization to formulate Occupation Health and Safety Policies and

    Objectives in accordance with legislative requirements and identified Occupational

    Health and Safety hazards and associated Risk assessments. These requirements shall be

    implemented by the Organization and is dedicated to save Life, Property and

    Environment.

    RELATIONSHIP BETWEEN OCCUPATION & HEALTH:

    Occupational diseases are those, which may arise out of or in the course of

    employment.The state of health of the worker can influence his ability to work Safely

    and Efficiently. The environmental factors, such as: presence of Contaminants in the

    air, Physical factors like heat, humidity, noise, radiation, etc. have effect on the state of

    workers health. Workers are at risk of getting exposed to toxic agents.

    It is therefore, is important that the employees are to be kept in healthy state.

    MODE OF ACTION OF A HAZARD:

    The main entries of toxic substances into human body are:

    Inhalation.

    Skin absorption.

    Ingestion.

    PREVENTION:

    Satisfactory maintenance, Good House Keeping, Education of the employees and proper

    Personal Hygiene are the four items, which help in the prevention of workers

    occupational illness.

    4

  • 8/14/2019 Project on Fire

    5/30

    OCCUPATIONAL HEALTH LEGISLATION

    FOR PROTECTION OF WORKERS HEALTH. (ILO). has developed instruments

    such as: -

    Hours of work.

    Night work.

    Weekly rest.

    Paid leave.

    Guide line of workers health protection. Improvements in working conditions.

    Protection against Specific Risks. (Handling of Toxic materials, Lifting & carrying of

    heavy loads,)

    Air Pollution, Noise, & Vibration.

    INDUSTRIAL INJURY:

    Industrial injury or accident means any Organic disturbance whether immediate or

    subsequent or Death, occurring suddenly in the course of the employment or in

    consequence thereof, irrespective of the place or time where it occurs.

    Injuries may be: Temporary incapacity.

    Permanent Partial Incapacity.

    Permanent Total Incapacity.

    Death.

    5

  • 8/14/2019 Project on Fire

    6/30

    FIRE TRIANGLE OR PYRAMID

    Three conditions have long been regarded as essential components of any fire :

    1. Fuel (i.e. the combustible material).

    2. Oxygen (from the atmosphere).

    3. Heat (essential to start the fire initially, but maintained bye the fire itself once it has

    started).

    These are familiar to fire fighters as the fire triangle or pyramid. If any one

    of these conditions is removed, the fire goes out. Methods of fire fighting thus depend on

    removing or shutting off the source of fuel, excluding oxygen or removing heat from the

    fire faster than it is liberated. A fourth condition is now recognised. Flames proceed

    chemically as branched chain reactions through the intermediary of free radicals which

    are constantly being formed and consumed. If the free radicals can be removed and

    prevented from continuing the chain reaction, the flame goes out.

    Various chemicals used in dry powder and halogenated hydrocarbon

    extinguishers capture free radicals and put out the fire in this way. Potassium bicarbonate

    is more effective than sodium bicarbonate and free halogen radicals, especially bromine

    formed when a brominated hydrocarbon meets a fire, are also effective. Thus the familiar

    fire triangle becomes a pyramid and now includes the fourth condition.

    6

  • 8/14/2019 Project on Fire

    7/30

    FIRE PROTECTION IN PETROCHEMICAL INDUSTRY

    From the above one car well imagine the potential fire risks in a

    petrochemical industry. The fire protection can be divided into three phases :

    i. By good plant, design and layout

    ii. Fire control keeping the fires localised

    iii. Fire extinguishment

    i. Plant Design & Layout : A good plant, design and layout, with strict adherence

    to safe operating procedures, proper built-in fire prevention system, fire-fighting

    training and adequate emergency plan to meet fire emergencies, is the best way to

    minimise the possibility of fire damages. Factors to be considered for the plant

    layout include adequate spacing and proper arrangement of various utilities,

    process units, storage units and vessels, loading and filling installations. For plant

    layout, safety rules laid down in the petroleum act should be followed.

    ii. Fire Control : This embodies protection of tanks, pressure vessels, structures,

    pipelines and equipment that are effected by direct flame impingement or by

    radiate heat exposure. Cooling prevents the spread of fire from its point of origin

    to the surrounding areas.

    iii. Fire Extinguishers : After adequate fire control measures fire is extinguished by

    employing suitable extinguishing media, like water, foam, dry chemical powder,

    Co2, Halogenated vapourising .

    Storage Tanks

    In a petrochemical complex, storage tanks of various types of storing the raw materials

    like Naptha, and Zylene as also the other products are required. These materials beinghighly inflammable adequate fire protection, fire prevention and fire-fighting

    arrangements are very essential. In case of any fire emergency, there must be

    arrangement to cool the tanks which is involved and the surroundingones. Arrangements

    for fighting the fire is also necessary, while planning the fire protection arrangement, it

    should worked out on the basis of meeting a major fire indicants. Among the

    extinguishing media water is employed extensively for cooling and foam generation. The

    maximum water flow rate is determines by taking into consideration the possibility of

    following simultaneous operations.

    7

  • 8/14/2019 Project on Fire

    8/30

    i. Water for foam generation.

    ii. Water for cooling.

    i. Water for foam generation : As per N.F.P.A. Handbook and code and American

    Institute Standard for petroleum refineries, water for foam generation for fixed

    foam pourers should be provided not less than 4.03 L/min for each IM2 of the

    liquid surface area. For hose streams, at least 6.5 Lit/min of water should be

    provided. In case of liquid hydrocarbon a delivery rate of 300 liters of foam/m2 of

    burning area is specified for a minimum period of 10 min.

    ii. Water for cooling : In a fire emergency the tanks which are on fire to be cooled

    as also the adjoining tanks are to be protected from exposure. For these purposes

    a flow rate of 10.2 L/min to 20.4 L/min per m 2 and 8.16 L/min 10.2 L/min

    respectively is considered satisfactory.

    Water Storage

    Adequate water storage is one of the most essential requirement of fire-fighting system.

    The total capacity of water storage as usually based on 4-10 Hrs. duration of fire-

    fighting. Provision storage tanks. The fire water storage tanks should be so placed that

    water can be delivered under gravity in case of failure of all pumps.

    Fire Water Supply System

    Water supply arrangement should be designed for a reliable and adequate

    supply of water under pressure (7 kg/cm2) for fire-fighting at each strategic point. This is

    generally measured by laying independent fire water mains of appropriated diameter

    along plant roads and access codes in block system. The main network is arranged in

    such a way that each area is surrounded by mains and sub-headers. Block valves, on the

    ring main, for maintenance purpose are placed at suitable intervals in such a way that

    they always ensure sufficient water supply for the operation of fire-fighting appliances.

    8

  • 8/14/2019 Project on Fire

    9/30

    Fixed Installations

    i. Fire Hydrant : Hydrants are to be placed at suitable intervals on fire water

    mains. Normal distance between the hydrants is 45 m to 90 m depending upon

    layout of area, water requirement. Discharge from each hydrant should be 1125

    l/min at a high pressure.

    ii. Hose Reels : For immediate availability of water in process area permanently

    connected hose-reels are used extensively. These reels should be provided with

    40 mm bore hose of 30 m length.

    iii. Monitors (For Water/Foam) : Fixed monitors are preferred for spot use.

    Because of limited area coverage from these monitors careful consideration has

    to be given in locating the same to ensure maximum effectiveness. Water stream,water spray/jet could be applied through the monitors by using co9mbination

    nozzles.

    Water Spray System

    Water spray cooling system are usually provided to minimise fire exposure.

    Manual / automatic/ remote controlled water spray is practically useful for cooling un-

    insulated steel structures elevated pipes, vessels, spheres etc.

    Water Fog System

    Water fog systems are intended to reduce fire intensity by mixing of water

    with fuel vapour or by the contact of fire drops or a very fine mist of water with oil

    surface. Water fog is effective on viscus oil or high flash point oils, where areas are

    within the range of fog nozzles. However, except under ideal conditions, it is seldom

    effective for extinguishment of fires in gasoline or other low flash point products. Pumps

    handling, hydrocarbon, compressors control valve, main folds, columns, and other

    9

  • 8/14/2019 Project on Fire

    10/30

    vessels under high temperature and pressure are protected with water fog systems. These

    systems can be either manual or automatic.

    Portable Fire Extinguishers

    Since in a petrochemical industry most of the fire encountered are that of

    liquid hydrocarbon, or vapours, portable extinguishers such as foam, dry powder, Co2 in

    adequate numbers are to be provided at strategic points to tackle a fire at its incipient

    stage.

    Carbon Dioxide And Other Inert Gases

    These systems must be used with great caution indoors when people are

    present, due to their asphyxiating action in lowering the oxygen content of the air. In at

    least one case a man fighting a fire in a basement with carbon dioxide extinguishers

    which were handed down to him from above collapsed and died as a result of oxygen

    deficiency in the atmosphere.

    Gas extinguishing systems consist of a supply of the inert gas under pressure

    (usually in cylinders), a system of pipework and valves delivering the inert gas to the

    points of application and an automatic detection and initiating system which opens inert

    gas valves once the fire has been detected. It also, in many cases, closes doors and

    ventilation ducts. These systems operate by reducing the oxygen content of the

    atmosphere and/or by interrupting the chemical reaction in a flame.

    Most of the gases used are suitable for electrical equipment and plantshandling flammable liquids. This system is particularly suitable for protecting valuable

    equipment which is easily damaged by water and foam, such as computers. For these

    systems to operate most effectively, the fire fighting equipment should be housed in a

    gas-tight compartment which is closed to the atmosphere when a fire starts. Carbon

    dioxide installations need special care to avoid introducing risks of ignition by static

    electricity.

    10

  • 8/14/2019 Project on Fire

    11/30

    Dry Powder

    Dry powder is a term used for various free-flowing powders which when

    poured or otherwise discharged over a fire will extinguish it. The compositions of many

    fire extinguishing powders are not publicised by their makers for obvious reasons. They

    generally contain three principal ingredients each with a particular function.

    1. Sodium or potassium bicarbonae. These liberate carbon dioxide when heated.

    Bicarbonates are thus a convenient means of applying carbon dioxide. They also

    react with and neutralise acids and some other reactive compounds and preventdamage from acids released by a fire. Potassium bicarbonate is claimed to be more

    effective than sodium bicarbonate due to its greater chain terminating effect.

    2. Certain finely powdered salts of metals which when present as a dust in the

    atmosphere strongly absorb radiant heat, thereby cooling and in some cases

    extinguishing flames.

    3. A compound which prevents the powder particulars from adhering to one another

    and forming lumps, thus preserving the free-flowing properties of the powder.

    Dry powder installations comprise dry powder container to which a gas

    cylinder (usually carbon dioxide) is coupled, and a system of piping and outlets which

    are located above the places where fires are likely to break out. They can be operated

    automatically or manually by opening valve on the gas cylinder so that the gas drives the

    powder to the outlets.

    These installations are suitable for flammable liquids and electrical

    equipment and for protecting some processes involving solids which are easily damaged

    by water or foam.

    Portable Appliances

    Portable fire extinguishers may be used to deliver water, dry powder, foam,

    carbon dioxide or a vapourising liquid to the seat of a fire. Their use should, as far as

    11

  • 8/14/2019 Project on Fire

    12/30

    possible, be standardised and the minimum number of types necessary should be carried.

    Hose reels are generally preferable.

    Supervisors should be abel to identify the different classes of fires and should

    know which type of portable extinguisher to use. All personnel should know how to

    recongnise and use the various types of extinguishers present. Practice sessions should be

    set up to ensure that all personnel act promptly and effectively in dealing with small

    fires.

    12

  • 8/14/2019 Project on Fire

    13/30

    Portable Water Discharging Extinguishers

    Extinguishers which deliver water operate in various ways:a. The water bucket. This is the simplest of all; it must, however, be kept full of clean

    water and always in the place reserved for it. Some skill is required in directing the

    contents of a water bucket onto a fire probably more so than closed portable

    extinguishers with nozzles.

    b. Gas pressure applied from a cartridge. A small cartridge of liquefied carbon dioxide

    is held inside the top of the cylindrical extinguisher. The cartridge has a brass cap

    which is pierced by a plunger passing through a gland in the top of the extinguisher.

    This is actuated by a sharp blow by the hand to the top of the plunger. Gas released in

    the extinguisher drives the water out through a discharge tube which extends to the

    bottom of the cylinder and is connected outside the cylinder to a nozzle via a short

    length of flexible hose.

    c. Stored gas pressure. The whole extinguisher is pressurised with gas at the time of

    charging with water. Water is discharged by opening a valve on the discharge tube.

    d. Gas pressure formed by reaction between an acid and a carbonate within the

    extinguisher. The extinguisher has an inner container filled with an acid solution

    (generally aluminum sulphate). The main body or outer container of the extinguisher

    is filled with a solution of sodium bicarbonate.

    The contents of the inner cylinder are released into the outer cylinder by inverting the

    cylinder and releasing a spring operated plunger. When the solutions mix, gas is

    formed which pressureises the extinguisher. A jet of water issues through a nozzle on

    the upper part of the extinguisher, so ling as the extinguisher remains inverted. The

    flow of water stops when the extinguisher is turned the ritht way up and surplus gas

    escapes.

    e. Hand pump inside the cylinder. This is operated by a handle extending through a

    gland in the top of the cylinder.

    The applications and limitations of water extinguishers have already been

    discussed. Water is best used for fires on solid materials which may re-ignite if not

    adequately cooled. It can readily penetrate to reach a deep seated fire.

    when using a water-filled extinguisher, direct the jet at the base of the flame

    and keep it moving across the area of fire. a fire moving vertically should be attacked at

    13

  • 8/14/2019 Project on Fire

    14/30

    its lowest point and followed up. seek out any hot spots after the main fire is

    extinguished.

    Portable Foam Extinguishers

    Foam extinguishers are of two types, mechanical and chemical. These

    correspond to water extinguishers in which the pressure is derived from a gas cartridge

    and from chemical reaction respectively. But the chemical foam extinguisher, unlike the

    soda-acid type of water extinguisher, is used in the normal upright position. Portable

    foam extinguishers have a capacity from 4 to 10 liters and a range of about 7 m. 10 liters

    for foam are normally required to extinguish 1 m2 of burning liquid.

    When a liquid fire has been extinguished by foam, the foam blanket left over

    the liquid remains in position thus preventing re-ignition and allowing the liquid to cool.

    Foam extinguishers should therefore be used for liquid fires where the liquid has been

    burning for some time and has become hot.

    Foam is not effective on flowing liquids, whether the flow is horizontal or

    vertical. Foam conducts electricity and should not be used on live electrical fires. Most

    water miscible liquids break up ordinary foams.

    When a liquid on fire is in a container, direct the jet at the far inside edge of

    the container, or at an adjoining vertical surface above the level of the burning liquid.

    This breaks up the jet and allows the foam to build up and flow across the surface of the

    liquid. When this is not possible, stand well back and direct the jet slightly upward so

    that the foam falls on to the surface of the liquid. Move the jet gently from side to side to

    cover the surface of the liquid. Do not direct the jet into the liquid because this will dive

    the foam beneath the surface and render it ineffective. It may also splash the burning

    liquid on to surrounding objects.

    14

  • 8/14/2019 Project on Fire

    15/30

    Portable Dry Powder Extinguishers

    The use and composition of dry powder have already been discussed under

    fixed installations. Portable dry powder extinguishers are made with capacities from 2 to

    10 kg of powder. In operation and appearance they are like water extinguishers where thepressure is supplied from a gas cartridge. Their range is less than a water extinguisher,

    usually from 3-6 m.

    These are the best type of extinguisher for dealing with fires of flammable

    liquids. They extinguish the flames over the liquid and thus act faster than foam. They

    can deal with larger areas of burning liquid than other extinguishers of the same size, and

    they are effective on fires of flowing liquid. Dry powder can be safely used on electric

    fires. The main limitation of dry powder is that it gives no protetion against re-ignition

    after application ceases since it has poor quenching properties. It is less effective than

    foam on liquid fires where the liquid has become overheated (i.e. through prolonged

    burning).

    Two kilograms of dry powder can normally extinguish a liquid fire

    converting and area of one square meter when properly applied.

    Portable Carbon Dioxide Extinguishers

    Carbon dioxide extinguishers should only be used sparingly in buildings due

    to the dangers of asphyxiating personnel. A second hazard of carbon dioxide

    extinguishers is the formation of static electricity in the discharge which can ignite

    flammable vapours, sometimes with fatal consequences.

    15

  • 8/14/2019 Project on Fire

    16/30

    Carbon dioxide acts more rapidly than foam and is more suitable for dealing

    with fires which might spread to surrounding materials before a complete foam blanket

    could be formed over the burning liquid. Carbon dioxide extinguishers are suitable for

    dealing with small fires of liquids flowing over horizontal and vertical surfaces. They

    should be used where the main concern is to avoid damage or contamination by dry

    powder deposit or foam, for example to laboratory equipment or food preparation.

    The cooling properties of carbon dioxide are limited and it gives no

    protraction against re-ignition after application ceases. It is less effective that foam for

    very hot liquids burning in containers.

    Carbon dioxide extinguishers contain the carbon dioxide and high pressure as

    a liquid in steel cylinders, with a valve leading via flexible hose to a horn shaped

    discharge tube. These extinguishers are normally used with the valve uppermost so that

    carbon dioxide is discharged as a gas. If they are inverted, a mixture resembling snow of

    carbon dioxide gas and solid carbon dioxide is discharged, provided the extinguisher is

    full and the ambient temperature is not excessive.

    Portable carbon dioxide extinguishers have capacities ranging from 1 to 6 kg

    and a range from 1 to 3 m.

    Portable Vapourising Liquid (Halon) Extinguishers

    Portable vapourising liquid extinguishers are now mainly restricted to the use

    of two compounds, bromochlorodifluoro methane or BCF, and bromotrifluoro methane

    or BTM.

    These may be discharged either by gas cartridge (containing carbon dioxide)

    or by pressuring the container with nitrogen. They can be fitted with a control valve if

    desired, so that can be discharged in short bursts, but once the seal has been broken they

    should be emptied, recharged and resealed. Their main action is by excluding oxygen

    from the flames. Since they do not conduct electricity they can be sued on electrical fires.

    16

  • 8/14/2019 Project on Fire

    17/30

    They have less static electricity risk then carbon dioxide, but they present the same

    asphyxiation hazard. In addition there is some risk of forming toxic decomposition

    products when their vapours are in contact with very hot metal, although this risk is far

    less than with older types of vapourising extinguisher which contained carbon

    tetrachloride, methyl bromide and other compounds which are little used now because of

    the toxic problem.

    These extinguishers have a range of up to 6 m and 1 liter of liquid is

    sufficient to extinguish flames over an area of one square meter of burning liquid. The

    methods of using dry powder, carbon dioxide and vapourizing liquid extinguishers are

    essentially the same.

    On fires involving liquids, either in containers or on the ground, direct the jet

    or discharge horn towards the near edge of the fire and with a rapid sweeping motion

    drive the fire towards the far edge until all the flames are extinguished. On fires in falling

    liquids, direct the jet or horn at the base of the lames and sweep upwards.

    When dealing with electrical equipment fires, first turn off the current. Then

    direct the jet or horn straight at the fire. When the equipment is enclosed, direct the jet or

    horn straight at the fire. When the equipment is enclosed, direct the jet or horn into any

    opening so that it penetrates the interior.

    If the extinguisher has a control valve on the discharge, shut it when the fire

    appears to be extinguished, wait until the atmosphere clears and, if any flame is then

    visible, open the valve and discharge again.

    17

  • 8/14/2019 Project on Fire

    18/30

    PRINCIPAL CAUSES OF ACCIDENTS

    When we look at the piramid it indicates that there is a dilution in safe practices

    leading to undesired incidents by way of creating unsafe acts and unsafe

    condition in the plant.

    These unsafe practices can be eliminated if we properly document all the incidents

    including near misses. This documentation will help others to understand and

    identify the deficiency in the system and the consequence of the unsafe

    practices. This will help to avoid repetition of the same incident. The

    documentation also helps in developing improvement in the safe practices (to

    make procedures user friendly).

    1. Accident Review Report

    2. Incident Report

    3. Fire Report

    4.1 Accident Report

    In general shift concerned supervisor will make the report and sent the report to

    the safety dept. through dept. head within 24 hrs. of the accident occurrence.

    Other than general shift hours shift incharge (plant incharge) will make the

    report and send to safety dept. before the relieving from his shift through proper

    channel.

    18

  • 8/14/2019 Project on Fire

    19/30

    ACCIDENT REPORT FORMAT

    1. Name of the injured :

    2. Designation :_________ Emp.No._______

    3. Sex _______________M/F Age___________

    4. Address : _____________________

    _____________________

    5. Date of injury_________ Time of Injury_______

    6. Did the injured return to :___________________

    work after first aid,when?

    7. Description of Accident :

    (describe briefly)

    a) Where (location) exactly:

    did the accident occur?

    b) What exactly was the :

    injured doing at the

    time of accident?

    c) Name of the machine or :

    part caused accident ?

    d) Kind of power used to :

    run the machine. Mech/Elec/Hand

    8) Indicate below by 'X' whether in your opinion the

    accident is caused by :

    a) Physical causes

    i) Improper guarding? :

    ii) Defective equipment? :

    iii) Hazardous arrangement? :

    iv) Improper ventilation? :

    v) Improper dress or apparel? :

    vi) Any mechanical cause? :

    vii) Not listed? Describe briefly:

    19

  • 8/14/2019 Project on Fire

    20/30

    b) Unsafe Acts:

    i) Operating without authority? :

    ii) Failure to secure or warn? :

    iii) Working at unsafe speed? :

    iv) Made safety device inoperative/bypassed

    v) Used unsafe equipment or hands:

    instead of equipment?

    vi) Unsafe loading, placement? :

    vii) Worked on moving equipment? :

    viii) Took unsafe position? :

    ix) Teased, abused distracted etc?:

    x) Did not unsafe clothes or

    personal protective equipment?

    xi) Not listed? Describe briefly)

    c) Personal causes: (Indicate Yes (or) No

    i) Physical or in attention? : Yes/No

    ii) Lack of knowledge or skill? : Yes/No

    iii) Improper attitude? : Yes/No

    iv) Was he under the influence of : Yes/No

    drink/drug

    vi) Not listed? Describe briefly? : Yes/No

    9) What steps are taken to prevent : _____________

    similar accident?

    10) What other steps do you suggest : _____________

    to avoid same or similar accidents?

    11) Name of the Supervisor to whom : _____________

    the injured is responsible?

    12) Name and designation of two : 1) _____________witnesses.

    _____________

    2) _____________

    -------------

    Signature of the Dept.Head Signature of the Engr.

    Comments of the Safety Dept. or Review Committee

    20

  • 8/14/2019 Project on Fire

    21/30

    a) Cause of the accident:____________________________

    b) Precautions suggested: 1) ________________________

    2) _______________________

    3) _______________________

    21

  • 8/14/2019 Project on Fire

    22/30

    DETECTION AND COMMUNICATION SYSTEM

    COMBUSTIBLE GAS DETECTIVE SYSTEM

    APL has installed latest gas detection system all over the plant in the strategic areas.

    This helps to detect the gas leaks and acts as an early warning system. Whenever

    process gas leaks out from the process/storage system and likely to build up

    concentration to Lower Explosive Limit (LEL) in the atmosphere the detector

    system identifies any flammable gas or carbon monoxide and gives early alarm at 20%

    of the LEL or Threshold Limit value (TLV). If the gas continuous to leak and built up

    concentration second level alarm gives at 30% of the LEL. Immediately on receiving

    the first alarm on DCS (Digital control system) the location of the detector is

    identified and further action will be taken. Whenever carbon monoxide detector

    actuates, the alarm is received on the DCS panel. It has two levels of alarm like in

    the case of combustible gas detectors.

    CARBON MONOXIDE GAS DETECTION:

    A total of 73 gas detectors were installed out of which 15 are meant for analysing

    carbonmonoxide gas. This is a special feature in APL which helps to detect gas leaks

    at early stage and suitable/prompt action will be taken. The action to be taken will be

    announced on paging system for quick communication between control room and

    various parts of the plant. This will help to identify any emergency at an early stage

    thus major disaster can be avoided.

    FIRE ALARM SYSTEM:

    The plant is provided with fire alarm system. This consists of control panel with

    audio visual indications at fire station and manual call points throughout the plant at

    strategic locations. Hooter provision was made in the control room and laboratory also.

    The emergency can be initiated by breaking the manual call point glass. The

    location is known to fire & safety dept. through the control panel. The hooter along

    with emergency

    siren is heard simultaneously at fire station, DCS and Laboratory.

    22

  • 8/14/2019 Project on Fire

    23/30

    COMMUNICATION PROCEDURE:

    Person who notices Fire will break the Fire alarm glass (or) Dial 333 (Fire

    Station) EPABX or Use Public address system.

    The person giving the message should identify himself and give the message

    in short and clear about,

    Location

    Nature of Emergency

    Extent of damage

    After giving message he shall make an attempt to extinguish fire by using availableappropriate extinguishers.

    As the Fire Engine comes to the site, guide it to the scene of fire emergency.

    Firemen will give the same message to DCS (333), Lab (427), Security (400).

    The DCS Control Room operator will receive the message and arrange to record the

    message on the board and report the same to the emergency controller.

    "EMERGENCY-NO ENTRY" Board will be displayed by the Security at the main gate.

    MODE OF COMMUNICATION

    Fire siren(both electrical & manual)

    Internal telephones

    Public addressing system

    Wakie Takies

    P & T phones

    Hot lines facilities in between the mutual aid members

    Megaphone

    23

  • 8/14/2019 Project on Fire

    24/30

    FIRE FIGHTING TECHNIQUES

    Fire extinguishment can be accomplished by four (4) methods.

    Smothering.

    Removing Oxygen supply; Foam, CO2, DCP, Steam, Water fog are applied on burning

    surface that cuts off Oxygen supply thus fire gets extinguished. In case of Tanker

    fires,closing the lid extinguishes fire.

    Starvation:

    This method is adopted when material leaking from a ruptured/leaky pipe.Closing or nipping the leaking pipe extinguishes fire due to starvation of fuel.

    NOTE: When fighting a pressurised gas/vapour fire, the personnel and equipment

    around should be protected by water spray. While the fire is being extinguished by

    starvation of fuel, if the fire is extinguished by other means a vapour/gas cloud will

    form, which may explode causing greater damage. Hence extinguishing fire is to be

    carefully timed. The leaking systems should be purged with Nitrogen to prevent

    ingress of Oxygen.

    Cooling:

    The burning fuel is cooled below ignition point, water spray or fog is the best cooling

    medium. Foam also cools the burning fuel while smothering.

    Note:-Water spray and foam should not be used simultaneously on fire.

    Neutralization of Chain reaction:

    Every fire involves a chain reaction,in which a multitude of chemical reactions generate

    chemical compounds or elements,that sustain the process.These elements are

    called "free radicals".Some means of extinguishing,such as powders,can scavenge these

    very reactive radicals,thus preventing propagation of the fire.These means have anegative catalytic effect on the fire.

    24

  • 8/14/2019 Project on Fire

    25/30

    DEFINITIONS

    EMERGENCY

    Emergency is defined as a situation in which an inflammable / toxic material is

    leaking into open atmosphere which might have caught Fire or may catch Fire

    at any moment. This is a potentially dangerous situation which is beyond the

    control of operating group and needs services of Fire Department and Others.

    ON SITE EMERGENCY:

    If the emergency can be controlled with the available resources within the factory

    premises and does not spread outside the plant boundary it is termed as On- Site

    Emergency

    OFF SITE EMERGENCY:

    If the emergency becomes uncontrolled and leads to damage to life and damage property

    or environment within the factory and its neighbourhood community around the plant is

    termed as Off- Site Emergencywith the available resources within the factory premises

    and does not spread outside the plant boundary it is termed as On- Site Emergency

    NATURE OF EMERGENCY:

    Emergency as specified under this plan refers to occurrences of one or more of the

    following events.

    1. Fire

    2. Release of toxic vapour/Flammable gases:

    Release of toxic gas like carbon monoxide or flammable gas like Propylene, Purge

    Gas,Methane, Hydrogen which can cause Boiling liquid Expanding vapour Explosion

    (BLEVE) or

    vapour cloud explosion(VCE).

    CHIEF CO-ORDINATOR:

    C.E & C.O.O will be the Chief Coordinator. In the absence of C.E & C.O.O ,

    Senior Most person from Operations will be the Chief Co-ordinator.

    25

  • 8/14/2019 Project on Fire

    26/30

    EMERGENCY CONTROLLER:

    The Shift Chemical Engineer in-charge of the shift is designated as Emergency

    Controller. He will assume full responsibility of handling any emergency. He will

    wear

    red helmet in emergency for easy identification.

    FIRE ALARM (WAILING FIRE ALARM):

    Fire Emergency siren:-Sounding of Fire Siren intermittently at long. High peaks with

    short Low peak interval for a period of 1.5minute long.

    Evacuation siren:-3 times long high peak, 3 times short low peak siren.

    All clear siren:-Sounding of Fire Siren continuously for a period of 30 sec. toindicate

    that the emergency is over.

    FIRE PREVENTION FACILITIES

    Some of the fire prevention measures are as follows :

    1. Nitrogen blanketing provided to all storage tanks.

    2. Avoiding presence of free oxygen in the process

    gases.

    3. Avoiding heat or spark

    4. Avoiding accumulation of static electricity.

    5. Connecting vapor lines of all equipment to flare

    6. Providing flame proof electrical equipment as per

    hazardous zone classification.

    7. Providing lightening arrestors

    8. Providing gas detectors.

    9. Following effective P M schedules

    10. Following well established Safety systems.

    11. Employees training.

    12. Maintaining good house keeping.

    26

  • 8/14/2019 Project on Fire

    27/30

    13. Prevention of smoking.

    14. Prevention of cell phones

    27

  • 8/14/2019 Project on Fire

    28/30

    ABBREVIATIONS

    ACGIH - American Conference of Government Industrial

    Hygienists

    CCOE - Chief Controller Of Explosives

    ELCB - Earth Leakage Circuit Breaker

    FLP - Flame Proof

    PLT - Pipe Line Transfer

    ILO - International Labor Organization

    TAC - Tariff Advisory Committee

    NDC - Non-Destructive Testing

    PPE - Personal Protective Equipment

    LPA - Loss Prevention Association

    NEERI - National Environmental Engineering Research

    Institute

    MAH - Major Accident Hazard

    LEL - Lower Explosive Limited

    UEL - Upper Explosive Limit

    IDLH - Immediately Dangerous to Life and HealthP&ID - Process and Instrumentation Diagram

    PFD - Process Flow Diagram

    UNICEF - United Nations International Children Emergency

    Fund

    IAEA - International Atomic Energy Agency

    AGFFF - Aqueous Gel Film Forming Foam

    AFFF - Aqueous Film Forming Foam

    SHE - Safety, Health And Environment

    BLEVE - Boiling Liquid Expanding Vapor Explosion

    VCE - Vapor Cloud Explosion

    OISD - Oil Industry Safety Directorate

    ISRS - International Safety Rating System

    DGFASLI - Directorate General Factory Advice Service & Labor

    Institutes

    28

  • 8/14/2019 Project on Fire

    29/30

    CIMAH - Control of Industrial Major Accident Hazards

    NSC - National Safety Council

    MIC - Methyl Iso Cyanate

    SCBA - Self Contained Breathing Apparatus

    TREMCARD - Transport Emergency Card

    CFC - Chloro Fluoro Carbons

    UL - Underwriters Laboratories

    HAZOP - Hazard and Operability Studies

    BIS - Bureau of Indian Standards

    ISO - International Organization for Standardization

    WTO - World Trade Organization

    ISO-9001 - Quality Management Systems

    ISO 14001 - Environmental Management Systems.

    PEL - Permissible Exposure Limit

    STEL - Short Term Exposure Limit

    TWA - Time Weighted Average

    TLV - Threshold Limit Valve

    MSDS - Material Safety Data Sheet

    COD - Chemical Oxygen Demand

    BOD - Biological Oxygen Demand

    APELL - Awareness And Preparedness For Emergencies At

    Local Level

    EIP - Emergency Information Panel

    OHSMS - Occupational Health & Safety Management

    Systems

    29

  • 8/14/2019 Project on Fire

    30/30

    BIBLIOGRAPHY

    Safety Magazines & Manuals

    Internet

    Safety Handbooks