k j k j k j $ K $ K ! . ! . ! . ! . $ K $ K " ) ! . ! . $ K $ K $ K $ K # * # * # * # # # # # ! ! ! ! ! ! ! ! 500 Ø 400 Ø 400 Ø 500 Ø 400 Ø 450 Ø 500 Ø 500 Ø 600 Ø 300 Ø 300 Ø 500 Ø 300 Ø 300 Ø 300 Ø 300 Ø 300 Ø 200 Ø 300 Ø 300 Ø 300 Ø 300 Ø 300 Ø 300 Ø 300 Ø 250 Ø 250 Ø 300 Ø 300 Ø 300 Ø 400 Ø 300 Ø 300 Ø 300 Ø 300 Ø 300 Ø ´ Legend # * Existing Region / Town Water Storage (Sharon & Holland Landing east tanks to be decommissioned) ! . Existing Region / Town Well " ) Existing Town Water Pump Station $ K Exist. / Prop. Region Water Meter Chamber ! Proposed Pressure Reducing Valve # Proposed Region Water Storage Existing Region Trunk Watermain Proposed Region Trunk Watermain Proposed Town Trunk Watermain Proposed Pressure District Boundary Service Area Boundary k j Special Study Area Natural Heritage Systems A and B Greenbelt Watercourse Waterbody PROJECTED WATER SYSTEM ULTIMATE BUILDOUT SCENARIO 0 1 2 0.5 Km Figure No. 4 Project No. 5941 April 2009 NOTE: TOWN EXISTING AND PROPOSED LOCAL SYSTEMS ARE NOT SHOWN. INFRASTRUCTURE ALIGNMENTS SHOWN ARE CONCEPTUAL. EAST 'A' EAST CENTRAL 'A' CENTRAL WEST Queensville Sd Rd Doane Rd Mount Albert Rd Herald Rd Davis Dr Warden Ave Woodbine Ave Future Hwy 404 Leslie St Yonge St 2nd Concession Bathurst St Green Lane EAST Proposed Pressure District Hwy 404

Upload: others

Post on 20-Jul-2022

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PROJECTED WATER SYSTEM ULTIMATE BUILDOUT SCENARIO

kj

kj

kj

$K

$K

!.

!.!.

!.

$K

$K

")

!.

!.

$K $K$K $K

#*

#*

#*

#

# #

#

#

!

!

!

!

!

!

!

!

500 Ø

400 Ø

400 Ø

500 Ø

400 Ø

450 Ø

500 Ø

500 Ø

600 Ø

300 Ø

300 Ø

500 Ø

300 Ø

300 Ø

300 Ø

300 Ø

300 Ø

200 Ø

300 Ø 300 Ø

300 Ø

300 Ø300 Ø300 Ø

300 Ø

250 Ø

250 Ø

300 Ø

300 Ø

300 Ø

400 Ø

300 Ø

300 Ø

300 Ø

300 Ø

300 Ø

´ Legend#* Existing Region / Town Water Storage

(Sharon & Holland Landing east tanks to be decommissioned)

!. Existing Region / Town Well") Existing Town Water Pump Station$K Exist. / Prop. Region Water Meter Chamber! Proposed Pressure Reducing Valve# Proposed Region Water Storage

Existing Region Trunk WatermainProposed Region Trunk WatermainProposed Town Trunk Watermain

Proposed Pressure District BoundaryService Area Boundary

kj Special Study AreaNatural Heritage Systems A and B

GreenbeltWatercourseWaterbody

PROJECTED WATER SYSTEMULTIMATE BUILDOUT SCENARIO

0 1 20.5 Km Figure No. 4Project No. 5941

April 2009

NOTE: TOWN EXISTING AND PROPOSED LOCALSYSTEMS ARE NOT SHOWN.INFRASTRUCTURE ALIGNMENTS SHOWN ARECONCEPTUAL.

EAST 'A'

EAST

CENTRAL 'A'

CENTRALWEST

Queensville Sd Rd

Doane Rd

Mount Albert Rd

Herald Rd

Davis Dr

Ward

en Av

e

Wood

bine A

ve

Futu

re Hw

y 404

Lesli

e St

Yong

e St

2nd C

once

ssion

Bathu

rst S

t

Green Lane

EAST Proposed Pressure District

Hwy 4

04