Thermo Scientific Q Exactive HF-X hybrid quadrupole-Orbitrap mass spectrometer Pushing the leading edge in protein analysis

Upload: others

Post on 28-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Thermo Scientific Q Exactive HF-X hybrid quadrupole-Orbitrap mass spectrometer

    Pushing the leading edge in protein analysis

  • • Novel architecture with a high capacity transfer tube (HCTT) and electrodynamic ion funnel that increases ion transmission and boosts sensitivity for all analytes, from small molecules to native antibodies.

    • Increased acquisition speed and advanced precursor determination (APD) dramatically improves peptide sequencing speed and depth.

    • Robust quantitative workflows, including parallel reaction monitoring (PRM) and high-resolution data-independent acquisition (HR-DIA).

    • Available with the powerful BioPharma option to support all workflows in the characterization of biotherapeutics with enhanced sensitivity.

    • Superior consistency and performance set new standards in quantitative accuracy, sensitivity and reproducibility for rigorous research workflows in large-scale studies of challenging protein samples.

    Accelerating insights, from discovery to verification

    2

    Advanced Active Beam Guide

    (AABG)

    Electrodynamic Ion FunnelHyperQuad Mass Filter with Advanced Quadrupole

    Technology (AQT)

    Ultra High Field Orbitrap Mass Analyzer

    C-Trap

    HCD Cell

    High Capacity Transfer Tube

    Understanding biomolecules as drug targets, disease markers, and therapeutic agents demands highly sensitive analysis of complex biological samples, without sacrificing robustness and speed. The Thermo Scientific™ Q Exactive™ HF-X hybrid quadrupole-Orbitrap™ mass spectrometer rises to the challenge as a versatile platform, setting new standards in sensitivity, performance and productivity for any workflow. Building on the proven performance of the Thermo Scientific™ Q Exactive™ hybrid quadrupole-Orbitrap™ MS family of instruments, the new Q Exactive HF-X mass spectrometer couples a high field Thermo Scientific™ Orbitrap™ mass analyzer with a high capacity transfer tube and electrodynamic ion funnel that maximize ion loading and transmit ions over a broad mass range.

    As a result, the instrument delivers a bright, focused and ion-rich beam, which translates to high sensitivity and excellent stability in analysis quality from run to run. Smart instrument control features match the superior ion transmission with increased acquisition speed and even more sophisticated data-dependent acquisition and analysis strategies to meet data quality needs at every stage of your work, from discovery to verification and quantitation.

  • Proteins identified faster than everThe Q Exactive HF-X mass spectrometer boosts productivity in protein identification, while maintaining the superb accuracy of the high field Orbitrap mass analyzer. Superior ion transmission, together with new scan rates up to 40 Hz, drive more efficient use of the Orbitrap mass analyzer. As a result, the Q Exactive HF-X mass spectrometer takes half as long to perform a typical proteomic analysis as the Thermo Scientific™ Q Exactive™ HF hybrid quadrupole-Orbitrap™ mass spectrometer. This results in up to 40% more unique peptide identifications per unit time, so you can shorten your time-to-results at any throughput scale and at any depth of analysis.

    Same protein identifications in half the analysis timeThe same cell line digest was run in triplicate using a 30 minute separation on a Q Exactive HF-X MS and a 60 minute separation on a Q Exactive HF MS. The Q Exactive HF-X MS identified almost the same number of protein groups in half the time, achieving an almost 2-fold improvement in analysis time. This represents a tremendous potential throughput advantage for large scale proteomic studies.

    Increased peptide ID efficiencyIn a similar triplicate analysis, a cell line digest was run on both the Q Exactive HF-X MS and Q Exactive HF MS systems, this time using a 60 minute separation on both systems. Results show that the Q Exactive HF-X MS was able to identify significantly more peptides in the same amount of time, resulting in improved proteome depth and protein coverage.

    Faster, with same high quality results In a similar triplicate analysis, a cell line digest was run on the Q Exactive HF-X MS at two different MS2 resolution settings: 7,500 and 15,000. The peptide score distribution (>80,000 peptides), demonstrates that the Q Exactive HF-X MS achieves the perfect balance between resolution and reliable MS2 spectra without sacrificing spectral quality.

    -560 min 30 min 60 min 60 min-4 -3 -2 -1 0 1

    3,831

    Protein Groups

    4,083

    Comparable IDs in half the time

    Same data in half the time

    32,045

    PeptidesNormalized peptide score distribution (Ln)

    22,959

    � Q Exactive HF 60 min

    � Q Exactive HF-X 60 min

    � Q Exactive HF 60 min

    � Q Exactive HF-X 30 min

    � Q Exactive HF

    � Q Exactive HF-X

    Increased peptideID efficiency

    Suitable transient length for maximal productivity

    High confidence spectra at 7,500 resolution

    3

  • Excellent peptide quantitation reproducibility

    Maximizing protein quantitation precisionThe Q Exactive HF-X MS in combination with Thermo Scientific™ Proteome Discoverer™ software enables the DDA+ workflow for increased protein coverage and quantitation precision. 1 µg of HeLa digest was analyzed at 120,000 resolution and MS1-based analysis yielded 4,383 proteins with 87% of the proteins quantified at a CV of

  • Optimal separation of TMT reporter ions A dedicated scan mode of the Q Exactive HF-X mass spectrometer with a resolution setting of 45,000 (FWHM) at m/z 200 optimally resolves reporter ions of the Thermo Scientific™ TMT10plex™ Isobaric Mass Tag Labeling Kit, and frees up scan time to quantify 10–20% more peptides in discovery experiments.

    Smart corrections to target more peptides for quantificationParallel reaction monitoring (PRM) is further enhanced with a new dynamic retention time correction (dRT) technique. The Q Exactive HF-X mass spectrometer compensates for run-to- run retention time variation by adjusting scheduled retention time windows (RTWs) on the fly. Thus, the instrument assigns retention times with greater accuracy and captures precursors within narrower RTWs. Consequently, a greater number of peptides can be scheduled for quantitation in a run while maintaining a sufficient acquisition sampling rate for reliable and precise quantification.

    130.13 130.14 130.15m/z

    130.13504R=66,702

    130.14114R=66,202

    130.13504R=87,702

    130.14114R=86,902

    96 msec vs128 msec transient

    A. RTW: 1 min dRT: OFF

    B. RTW: 2 min dRT: OFF

    C. RTW: 3 min dRT: OFF

    D. RTW: 4 min dRT: OFF

    E. RTW: 1 min dRT: ON

    Pep

    tide

    Targ

    ets

    1-19

    8

    Replicate 1–30 Replicate 1–30 Replicate 1–30 Replicate 1–30 Replicate 1–30

    30 replicate injections with 4 different RTW applied and dramatically improved peptide targeting with the use of dynamic retention time correction (dRT). The same 198 scheduled peptide precursors were monitored by 3 fragments each. To mimic common challenges in nano HPLC approaches, the gradients were randomly switched between 6 slightly different gradients. Graphs A to D show the results when dRT is switched off with increasing RTWs from 1 to 4 minutes. With a narrow 1 minute RTW, the red marks show where many targeted peptides were not sampled, likely because shifts in retention time caused them to elute outside the programmed RTW. As we increase the RTW from 1 to 4 minutes, the wider RTW is better able to accommodate for RT shifts from run-to-run. The last graph E demonstrates that dynamic retention time adjustment is able to compensate for shifts in retention time, such that there are very few missing measurements.

    Improved TMT Performance. An MS2 spectrum showing baseline resolution of TMT10-130N and TMT10-130C reporter ions. A dedicated TMT scan mode enables the Q Exactive HF-X MS to effectively resolve TMT reporter ions in only 96 msec versus the previous 128 msec method. This assures accurate quantitative results and allows more scans per run for deeper levels of analysis.

    5

    The next level in state-of-the-art proteomicsA single platform that can span the complete workflow spectrum of today’s quantitative proteomics must integrate high sequencing speed with maximum sensitivity and selectivity. Confidently discover and quantify proteins of interest with label-free, SILAC, or isotopically labeled tandem mass tags (TMT) quantitation strategies, and validate with parallel reaction monitoring (PRM). The enhanced sensitivity of the Q Exactive HF-X mass spectrometer enables unparalleled workflow versatility to accommodate every stage of proteomic analysis.

  • A novel workflow brings intact proteins into focusTop-down methods open multiple opportunities in proteomics: you can quantitatively track proteoforms of interest, and detect degradation products, sequence variants and post-translational modifications. A challenge in top-down approaches is the limited dynamic range of proteoform characterization. Abundant proteoforms tend to be fragmented redundantly, and their detection can obscure new species from identification. The Q Exactive HF-X mass spectrometer introduces a new intelligent data-dependent acquisition workflow for intact proteins that facilitates deeper insights from top-down proteomics.

    On-the-fly selection of proteoforms that matterDuring the MS1 scan, the instrument leverages advanced DDA algorithms to perform on-the-fly deconvolution of differently charged precursors from a single protein, and selects the most abundant form while redundants are placed on an exclusion list. Similarly, smart algorithms automatically determine the optimal collision energy for the fragmentation of each selected precursor to generate high-resolution scans for MS2 analysis and protein identification. This streamlined top-down characterization eliminates superfluous work and captures a wider picture of the proteins in a sample.

    Rel

    ativ

    e A

    bund

    ance

    500 600 700 800 900 1000 1100 1200 1300 1400m/z

    742.8353z=30

    696.5052z=32

    795.9300z=28

    857.0239z=26

    891.2571z=25672.9588z=19

    631.5187z=41

    968.7302z=23 1012.6560

    z=22

    1172.3279z=19

    588.5482z=44 1237.5236z=18 1310.2670

    z=17

    RT: 0.00 - 40.02

    0 5 10 15 20 25 30 35 40Time (min)

    0

    20

    40

    60

    80

    100

    Rel

    ativ

    e A

    bund

    ance

    0

    20

    40

    60

    80

    100

    17.36820.89

    36.47413.27

    15.49783.14 17.56

    776.74 25.001110.48

    20.48818.99

    13.52742.8412.18730.26

    24.061014.519.45

    699.9236.76

    413.276.68621.431.15

    574.92 5.36644.72

    22.37897.37

    34.51633.15

    28.70485.11

    32.98559.13

    NL:6.98E7Base Peak F: ms MS EColi_RPs_Top3_low_high

    Rel

    ativ

    e A

    bund

    ance

    500 600 700 800 900 1000 1100 1200 1300 1400m/z

    742.8353z=30

    696.5052z=32

    795.9300z=28

    857.0239z=26

    891.2571z=25672.9588z=19

    631.5187z=41

    968.7302z=23 1012.6560

    z=22

    1172.3279z=19

    588.5482z=44 1237.5236z=18 1310.2670

    z=17

    RT: 0.00 - 40.02

    0 5 10 15 20 25 30 35 40Time (min)

    0

    20

    40

    60

    80

    100

    Rel

    ativ

    e A

    bund

    ance

    0

    20

    40

    60

    80

    100

    17.36820.89

    36.47413.27

    15.49783.14 17.56

    776.74 25.001110.48

    20.48818.99

    13.52742.8412.18730.26

    24.061014.519.45

    699.9236.76

    413.276.68621.431.15

    574.92 5.36644.72

    22.37897.37

    34.51633.15

    28.70485.11

    32.98559.13

    NL:6.98E7Base Peak F: ms MS EColi_RPs_Top3_low_high

    Base peak chromatogram of sample X with a 40 min gradient.

    Full MS scan in Protein Mode at a resolution setting of 7,500.

    On-the-fly deconvolution based on charge envelope to select dominant proteoforms (TopN).

    Thermo Scientific™ ProSightPC™

    software search to identify each

    analyzed protein

    Powerful workflow eliminates redundant fragmentation to identify more proteins.

    500 600 700 800 900 1000 1100 1200m/z

    0

    20

    40

    60

    80

    100

    798.1074R=68106

    z=15855.1163R=66706

    z=14

    870.6557R=65406

    z=11795.2241R=66004

    z=28920.8149R=61806

    z=13735.0701R=71706

    z=3957.7191R=59606

    z=10

    508.6336R=84806

    z=3727.3240R=70206

    z=14

    672.2065R=71806

    z=5

    1102.0981R=55206

    z=2

    1018.0504R=55906

    z=2

    1167.6456R=50306

    z=2

    Rel

    ativ

    e A

    bund

    ance

    MS2 Proteoform 1

    500 600 700 800 900 1000 1100 1200m/z

    0

    20

    40

    60

    80

    100

    798.1080R=68306

    z=15

    748.2898R=70906

    z=16

    798.3741R=70000

    z=15735.4065R=70506

    z=16870.6554R=63806

    z=11508.6342R=85806z=3

    703.3319R=70506

    z=17

    905.1116R=60806

    z=81102.0974R=55606

    z=2

    957.6191R=56406

    z=10

    579.8251R=73606

    z=4

    1167.6455R=49306

    z=2

    Rel

    ativ

    e A

    bund

    ance

    MS2 Proteoform 2

    500 600 700 800 900 1000 1100 1200m/z

    687.5533R=76106

    z=7

    756.7241R=72306

    z=7757.0096R=71902

    z=7754.2936R=72306

    z=7 801.9780R=70406

    z=6

    872.4727R=66906

    z=8

    687.2677R=75202

    z=7

    677.4052R=75806

    z=7 902.7396R=64406z=8635.2498R=77406

    z=8

    997.1076R=59906

    z=71031.4133R=55506

    z=7

    494.2994R=77806

    z=1

    1144.2770R=47600

    z=?0

    20

    40

    60

    80

    100

    Rel

    ativ

    e A

    bund

    ance

    MS2 Proteoform 3

    MS2 analysis of each proteoform fragmented with optimal collision energy and detected at a resolution setting of 120,000.

    50S ribosomal protein L7/L12 (P0A7K2)

    6

  • In-depth characterization of the intact mAb infliximabA. Full MS spectrum and total ion chromatogram obtained upon analysis

    under denaturing conditions at a resolution setting of 60,000 with automated charge state annotation of isotopically unresolved peaks

    B. Full MS spectrum and total ion chromatogram obtained upon analysis under native conditions

    C. Spectrum excerpt highlighting the baseline resolved detection of a complex glycoform pattern in the zoom of charge state 26

    D. Deconvoluted spectrum under native/denatured conditions

    Greater sensitivity reveals more details about proteins The High Mass Range mode of the BioPharma option was designed to enable the analysis of intact therapeutic proteins under native conditions detected above m/z 6,000 with high transmission. The superior ion transmission of the Q Exactive HF-X MS allows for using high resolution settings to better resolve protein modifications, such as glycosylations and conjugations. This instrument achieves unprecedented quality and detail in the analysis of large, complex analytes. In the case of intact Antibody-Drug Conjugates (ADC), drug-to-antibody ratios can be accurately determined without deglycosylation.

    In Protein mode, fast scan rates (16 msec transient) and superior sensitivity produce top-quality data to reveal antibody subunits that are typically difficult to resolve without chromatographic separation. Antibody heavy and light chains are clearly distinguishable in baseline-resolved spectra.

    1000 1500m/z

    0

    20

    40

    60

    80

    100

    Light chainLight chain (LC)

    Heavy chain

    Heavy chain (HC)

    0 1 2 3 4 5Time (min)Time (min)

    0

    20

    40

    60

    80

    100 1.6Injectionpeak

    Injectionpeak

    TICB

    m/z

    0

    50

    1000

    50

    100

    0 2 4 6 8

    0

    20

    40

    60

    80

    100

    Rel

    ativ

    e A

    bun

    dan

    ce/%

    BR

    elat

    ive

    Ab

    und

    ance

    3.6TICLC

    LC and HC

    HC

    A

    Unseparated LC & HCSeparated LC & HC

    1000 1500

    4.1

    Speed and sensitivity support superb quality detection of antibody light and heavy chains (A), even without chromatographic separation (B). The Q Exactive HF-X MS produces distinct, high-quality baseline-resolved spectra of antibody subunits with superior quality.

    A

    B

    C

    D

    5500 6000 6500m/z

    20

    40

    60

    80

    100

    Rel

    ativ

    e A

    bund

    ance

    z=26

    z=25

    z=24

    z=27

    z=28

    z=49z=53

    z=51

    2500 3500m/z0

    0

    0

    20

    40

    60

    80

    100

    Rel

    ativ

    e A

    bund

    ance

    5700 5740m/z

    20

    40

    60

    80

    100

    Rel

    ativ

    e A

    bund

    ance

    5722.8

    5729.2

    5712.8

    5735.35705.4

    Mass148000 148500 149000 149500

    0

    20

    40

    60

    80

    100

    Rel

    ativ

    e In

    tens

    ity

    G0F/G2F or (G1F)2

    (G0F) 2-2Lys(G0F) 2

    G0F/G1F

    G1F/G2F

    (G0F) 2 -1Lys

    (G0F/G1F) -2Lys

    (Man5)2

    [G0F/G2F or (G1F)2 ] -2Lys

    (Man5) 2 -2Lys

    0 10Time (min)

    6.54TICMAbPac RP

    0 10Time (min)

    7.67Salt peak TIC

    Acclaim SEC

    7

    A powerful, single platform for the analytical demands of BioPharmaThe enhanced sensitivity of the Q Exactive HF-X mass spectrometer across all BioPharma workflows provides a complete high performance analysis platform for biotherapeutic characterization. The BioPharma option increases the mass range and transmission for sensitive analysis of heterogeneous mAbs and ADCs under native conditions. In addition, it provides optimized conditions for subunit analysis and middle-down sequencing.

  • Find out more at thermofisher.com/QExactiveHFX

    © 2017 Thermo Fisher Scientific Inc. All rights reserved. SEQUEST is a registered trademark of the University of Washington. Mascot is a trademark of Matrix Science Limited. Byonic is a trademark of Protein Metrics Inc. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. BR64966-EN 0517M

    Proteome Discoverer SoftwareIdentify and quantify proteins in complex biological samples using Proteome Discoverer software. Proteome Discoverer software simplifies a wide range of proteomics workflows, from protein and peptide identification to PTM, analysis to isobaric mass tagging and both SILAC and label-free quantitation. It supports multiple database search algorithms (SEQUEST®, Z-Score, Mascot™, and Byonic™).

    BioPharma Finder SoftwareSave time and identify more with Thermo Scientific™ BioPharma Finder™ integrated software. Screen, identify and characterize intact proteins with higher productivity and confidence using Intact Protein workflow. Two deconvolution algorithms take full advantage of the high-quality, HRAM data produced by Orbitrap mass spectrometers. Confirm amino acid sequence, identify site and type of known and unknown PTMs while providing relative amounts using Peptide Mapping workflow.

    Compound Discoverer Software The complete small molecule identification and characterization solution, Thermo Scientific™ Compound Discoverer™ software is a flexible solution that offers a full suite of powerful tools to address mass spectrometry-based (MS) small molecule differential analysis, identification, and pathway mapping.

    TraceFinder SoftwareThermo Scientific™ TraceFinder™ software provides a complete quantitation and screening workflow for routine applications across multiple markets for GC- and LC-MS systems. TraceFinder software allows users to develop comprehensive assays with multiple levels of confirmations that can be refined to simplified workflows for technician-level operators.

    LipidSearch SoftwareThermo Scientific™ LipidSearch™ software processes LC-MS data, including high-resolution accurate-mass data generated by Orbitrap mass spectrometers, to make provide accurate lipid identification. It automatically integrates complex data into reports and dramatically reduces data analysis time.

    Accelerating productivity with software solutions