PVI-12.0-OUTD-Isolated GENERAL SPECIFICATIONS OUTDOOR MODELS PVI-12.0-I-OUTD-US PVI-12.0-I-OUTD-CAN AURORA TRIO

Upload: others

Post on 22-Nov-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PVI-12.0-OUTD-Isolated - Solacity Inc

PVI-12.0-OUTD-Isolated

GENERAL SPECIFICATIONSOUTDOOR MODELS

PVI-12.0-I-OUTD-USPVI-12.0-I-OUTD-CAN

AURORA TRIO

Page 2: PVI-12.0-OUTD-Isolated - Solacity Inc

Features

TRIO

AURORA TRIO

‘Electrolyte-free’ power converter to further increase the life expectancy and long term reliability

True 3-phase bridge topology for DC/AC output converter

Night Wake up button to access energy harvesting data and error log

Dual input sections with independent MPP tracking, allow optimal energy harvesting from two sub-

arrays oriented in different directions

High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting

Flat effi ciency curves ensure high effi ciency at all output levels insuring consistent and stable perfor-

mance across the entire input voltage and output power range

Anti-Islanding Protection

Watertight NEMA 4X enclosure

Integrated disconnect in compliance with NA Standards (-S and -S2 Versions)

RS-485 communication interface (for connection to laptop or datalogger)

Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

••••

••

•••••

Designed for commercial usage, this three-phase inverter is unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions. This device has two independent MPPTs and effi ciency ratings of up to 97.3%.

The HF isolation allows positive or negative ground confi guration. Versions are available with fully-integrated DC and AC disconnect options. The unit is free of electrolytic capacitors, leading to a longer product lifetime.

Page 3: PVI-12.0-OUTD-Isolated - Solacity Inc

Block Diagram and Typical Effi ciency

AURORA TRIO

IN1

+

-

MPPT 1(DC/DC)

IN2

+

-

MPPT 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

μP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L2

L3

N

PE

GROUNDFAULT

DETECTION

HFTRANSFORMER

HFTRANSFORMER

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1

IN2

+

-

+

-

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

STANDARD VERSION BLOCK DIAGRAM OF THREE PHASE ISOLATED INVERTER

IN1(+)

IN1(-)

IN1

IN2

+

-

+

-

IN2(+)

IN2(-)

-S AND -S2 VERSION

-S2 VERSION

L1 L1, S

L2 L2, S

L3 L3, S

N N, S

PE

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

EFFICIENCY PVI-12.0-I-OUTD

200 Vdc340 Vdc416 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Effi

cien

cy, %

% of Rated Output Power

200 Vdc

340 Vdc

420 Vdc

6,25%

12,50%

18,75%

25,00%

31,25%

37,50%

43,75%

50,00%

56,25%

62,50%

68,75%

75,00%

81,25%

87,50%

93,75%

100,00%

140 165 190 215 240 265 290 315 340 365 390 415 440 465 490 520

96.60-97.10

96.40-96.60

96.20-96.40

96.00-96.20

95.80-96.00

95.60-95.80

95.40-95.60

95.20-95.40

95.00-95.20

94.80-95.00

94.60-94.80

94.40-94.60

94.20-94.40

94.00-94.20

93.80-94.00

93.60-93.80

93.40-93.60

93.20-93.40

93.00-93.20

92.80-93.00

92.60-92.80

92.40-92.60

92.20-92.40

92.00-92.20

97.3

Input Voltage [V]

Efficiency PVI-12.0-I-OUTD [%] %

of O

utp

ut

Po

wer

Preliminary data subjet to change Preliminary data subjet to change

Page 4: PVI-12.0-OUTD-Isolated - Solacity Inc

AURORA TRIO

PARAMETER PVI-12.0-I-OUTD-US-480 PVI-12.0-I-OUTD-CAN-600

Input SideStart-up Input Voltage (Vdcstart) adj. 120...350 V adj. 120...350 VOperating Input Range (Vdcmin...Vdcmax) 0.7 x Vdcstart...520 V 0.7 x Vdcstart...520 VMPP Input range (Vmppmax,f-Vmppmin,f) at full power 250...470 V 250...470 VInput Voltage Range for Full Power Operation with Parallel Confi guration of MPP 250...470 V 250...470 V

Input Voltage Range for Full Power Operation with Independent Confi guration of MPP 260...470 V (@6,500W) / 240...470 V (@5,800W) 260...470 V (@6,500W) / 240...470 V (@5,800W)

Absolute Maximum Input Voltage Vmax,abs 520 V 520 VNumber of Independent MPP 2 (3 on -S2 version) 2 (3 on -S2 version)Maximum Input Current (Idcmax) 25.0 A 25.0 ANumber of DC Inputs Pairs 3 for each MPP 3 for each MPPInput ProtectionReverse Polarity protection Yes YesInput Short Circuit Current 29.0 A 29.0 AInput Side Varistors 4 (2 for each MPP) 4 (2 for each MPP)Photovoltaic Array Isolation Control GFDI GFDIDC Switch 600 V /32 A 600 V /32 AOutput SideAC Grid Connection (Vacmin...Vacmax) Three Phases Three PhasesRated Power (Pac,r) 12,000 W 12,000 WPower at 50°C/122°F 11,160 W 11,230 WPower at 60°C/140°F 8,950 W 9,020 WRated Grid Voltage (Vac,r) 480 Vac 600 VacAC Voltage Range 422...528 V 544...660 VMaximum Output Current (Iac,max) 16.0 A 13.3 A Rated Frequency (fr) 60 Hz 60 HzNominal Power Factor > 0.99 > 0.99Total Harmonic Distortion < 2% < 2%Output ProtectionAnti-islanding protection According to UL 1741 According to UL 1741Maximum AC Overcurrent Protection 20.0 A 20.0 AAC Side Varistors 3 plus gas arrester 3 plus gas arresterNight Time Disconnect Yes YesOperating PerformanceMaximum Effi ciency (ηmax) 97.3 % 97.3 %Weighted Effi ciency (EURO/CEC) - / 97.0 % - / 97.0 %Feed In Power Threshold 30 W 30 WStand-by Consumption < 8 W < 8 WNight-time power loss < 0.3 W < 0.3 WCommunicationMonitoring System (PC/Data logger) RS485/232 (opt.), Aurora Desktop (opt.) RS485/232 (opt.), Aurora Desktop (opt.)Remote Control RS 485, Wireless (opt.) RS 485, Wireless (opt.)User Interface 16 characters x 2 lines LCD display 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60°C /-13...140°F with derating above 45°C/113°F -25...+60°C /-13...140°F with derating above 45°C/113°FRelative Humidity < 100 % condensing < 100 % condensingNoise Emission < 50 db(A) < 50 db(A)Operating Altitude 2000 m / 6560 ft 2000 m / 6560 ftPhysical Environmental Protection Rating NEMA 4X NEMA 4XCooling Natural Natural

Dimension (H x W x D) 716mm x 645mm x 208mm / 28.2” x 25.4” x 8.2”958 mm x 645mm x 222m / 37.7”x12.8”x8.7” (-S/-S2)

716mm x 645mm x 208mm / 28.2” x 25.4” x 8.2”958 mm x 645mm x 222m / 37.7”x12.8”x8.7” (-S/-S2)

Weight 45.8 kg / 99.0 lb

48.5 kg / 107 lb (-S Version)51.7 / 114 lb (-S2 Version)

45.8 kg / 99.0 lb48.5 kg / 107 lb (-S Version)51.7 / 114 lb (-S2 Version)

Mounting System Bracket support Bracket supportWarranty 10 std up to 15/20 years opt. 10 std up to 15/20 years opt.SafetyIsolation Level HF transformer HF transformer Marking cCSAus cCSAusSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01 UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547 IEEE 1547Available Products VariantsStandard - Positive Ground PVI-12.0-I-OUTD-US-480-PG PVI-12.0-I-OUTD-CAN-600-PGStandard - Negative Ground PVI-12.0-I-OUTD-US-480-NG PVI-12.0-I-OUTD-CAN-600-NGWith DC Switch - Positive Ground PVI-12.0-I-OUTD-S-US-480-PG PVI-12.0-I-OUTD-S-CAN-600-PGWith DC Switch - Negative Ground PVI-12.0-I-OUTD-S-US-480-NG PVI-12.0-I-OUTD-S-CAN-600-NGWith AC and DC Switches - Positive Ground PVI-12.0-I-OUTD-S2-US-480-PG PVI-12.0-I-OUTD-S2-CAN-600-PGWith AC and DC Switches - Negative Ground PVI-12.0-I-OUTD-S2-US-480-NG PVI-12.0-I-OUTD-S2-CAN-600-NGPlease note: All data for PVI-12.0-I-OUTD-CAN is preliminary