q10 euro ncap 2020 hardware & fe model updates€¦ · a major update release of q10 euro ncap...
TRANSCRIPT
Q10 EURO NCAP 2020 HARDWARE& FE MODEL UPDATES Jerry Wang (Ph. D) & Fuchun Zhu
©2019 Confidential & Proprietary
2
Contents
• Part One – Brief of Q10 Euro NCAP 2020 upgrade kit • Part Two – Q10 Euro NCAP 2020 FE model updates
©2019 Confidential & Proprietary
3
2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020
Overview time line of Q10 developments
RequirementsDesign and Prototyping
Validation and Evaluation
EU funded projectEPOCh
Abdomen pressure sensor integration
FeedbackDesign updatesProduction
Hip liner
ASIS Load Cell
Requirements Q10 2020FE supported Trade off studyDesign and Prototyping
ValidationEvaluation
Euro NCAP initiative
Q10 2020 Final designProduction
Future harmonization with Euro NCAP?
UNECE Regulation 129
©2019 Confidential & Proprietary
4
Q10 Changes Driven By Euro NCAP Child WG
• Seating Posture◦ Match UMTRI Child Anthropometry – head and neck position
• Proper Belt Engagement and Kinematics◦ Shoulder belt – shoulder pad◦ Lap belt – thigh flesh
• Mass distribution improvement◦ Migrate mass from pelvis to thorax
• Other usage issues experienced in testing◦ Foot interference with front seat◦ Scapula interference with shoulder rubber and ribcage
©2019 Confidential & Proprietary
5
Euro NCAP 2020 Q10 Contents• Euro NCAP Child WG Decision: Sept 2018• Head and neck position at neck base
◦ Reposition the dummy according to UMTRI child seating posture
◦ Forward shift the neck by 20 mm◦ Rotate the head rearward by 5.3 degrees
• Shoulder liner to cover shoulder joints• Scapula eliminated • Mass shift pelvis to thorax 1.4 kg• Upper legs with solid flesh• Lower legs with shorter feet
©2019 Confidential & Proprietary
6
Q10 Euro NCAP 2020 Kit Status• Euro NCAP Q10 Upgrade Kit is finalized and available for the users• Euro NCAP New Test Protocol takes effective on Jan 1, 2020
• Euro NCAP Dynamic Tests – total 30 channels, plus 4 optional◦ Head acceleration x,y,z◦ Upper neck force Fx, Fy, Fz, moment Mx, My, Mz◦ Shoulder force Fx, Fy, Fz◦ T1 acceleration y (side only)◦ Chest (T4) acceleration x,y,z,◦ Chest displacement and rotation◦ Lumbar spine force Fx, Fy, Fz and moment Mx, My, Mz◦ Pelvis acceleration x,y,z◦ Pubis force Fy (side only)◦ Iliac wing (L&R) force Fx, My (optional)
MK-FO-00036C, Rev A
Part Two: Q10 Euro NCAP 2020 FE Models Development
©2019 Confidential & Proprietary
8
2015 2016 2017 2018 2019
Q10 2020 V1.0 Concept Model V1.1 V1.2
Reports to Euro NCAP, Advisory Board and Conferences
V1.0 Full Prototype 2017
New Q10Euro NCAP 2020 Design. FE model available for evaluation
Hardware Status• Validation/Testing• Third Party Evaluation
FE model release 3rdQ 2019
Q10 Dummy Model Development History/Status
March 2018: Based on evaluation results, Euro NCAP CWG decided for limited updateby restoring some original Q10 parts
Design/FE analysis loop done in all stages of development-concept to launch!
©2019 Confidential & Proprietary
9
• FEA V1.1 Model developed to follow Euro NCAP 2020 specifications; and released late 2018;
• V1.1 dynamic performance to mimic hardware closely;
• Updated parts of known materials, known geometry change◦ Solid/rigid metal parts spine and pelvis◦ Solid/rigid scapula◦ Solid/elastic shoulder pad*◦ Solid/elastic lower leg◦ Solid/elastic thigh flesh current production*
• Extra option (feature): *stiffness parameter variables in FEA model (Thigh, Shoulder liner)
Q10 Euro NCAP 2020 Dummy Model v1.1
©2019 Confidential & Proprietary
10
• V1.1 model represents the state of art design and functionality of the hardware kit/materials
• Thigh flesh/Shoulder liner parameters for stiffness variation
• Additional parameters on Jacket, neck, hip shields to help users run belt slip on shoulder and chin to clavicle contact studies
Q10 Euro NCAP 2020 Dummy Model v1.1
©2019 Confidential & Proprietary
11
• V1.1 SK model released in April 2019• The SK (side kit) arm with shoulder assembly is fitted on
the Euro NCAP 2020 v1.1 model• Modified scapula
Q10 Euro NCAP 2020 SK Dummy Model v1.1
MK-FO-00036C, Rev A
New Validation Tests for v1.2 ModelPlanned Release Date: 9/2019
• Neck mini sled tests• Lumbar spine mini sled tests• Abdomen foam drop tests• APTS pendulum impact tests
©2019 Confidential & Proprietary
13
• Focus on validating combined bending/torsion mode;• Total of 40 tests were executed at multiple speeds, with/without neck cable;• Considering possible hardware variations - two necks.
Neck Mini Sled Tests
Impactvelocity
Neck1 (EJ8877) Neck 2 (EJ6567)
With cable
Without cable
With cable Without cable
2 m/sTest 1 √ √ √ √
Test 2 √ √ √ √
3 m/sTest 1 √ √ √ √
Test 2 √ √ √ √
4 m/sTest 1 √ √ √ √
Test 2 √ √ √ √
5 m/sTest 1 √ √ √ √
Test 2 √ √ √ √
6 m/sTest 1 √ √ √ √
Test 2 √ √ √ √
©2019 Confidential & Proprietary
14
• Neck kinematics to replicate loading level seen in a vehicle test.• Initial Position reference for FEA established via Laser scanning.• Validation based on 3 independent sets of signals.a. Ballast Acceleration & Angular velocity outputs.b. Upper Neck Loadcell Forces & Moments.c. Lower Neck Loadcell Forces & Moments. c
b
a
Neck Mini Sled Tests
©2019 Confidential & Proprietary
15
Upper Neck Loads: 6 m/s (with Cable)
• Focused on Upper Neck Loadcell signals - important for EuroNCAP injury rating.
Neck Mini Sled Tests
TestV1.1V1.2
©2019 Confidential & Proprietary
16
Lower Neck Loads: 6 m/s (with Cable)
Neck Mini Sled Tests
TestV1.1V1.2
©2019 Confidential & Proprietary
17
Ballast Kinematics angular velocity: 6 m/s (with Cable)
Neck Mini Sled Tests
TestV1.1V1.2
©2019 Confidential & Proprietary
18
• Focus on validating combined bending/torsion mode;• Total of 32 tests were executed at multiple speeds, with/without lumbar cable;• Considering possible hardware variations - two lumbar spines.
Impactvelocity
Lumbar 1 (EJ2521) Lumbar 2 (EJ5778)
With cable
Without cable
With cable Without cable
3 m/sTest 1 √ √ √ √
Test 2 √ √ √ √
4 m/sTest 1 √ √ √ √
Test 2 √ √ √ √
5 m/sTest 1 √ √ √ √
Test 2 √ √ √ √
6 m/sTest 1 √ √ √ √
Test 2 √ √ √ √
Lumbar Spine Mini Sled Tests
©2019 Confidential & Proprietary
19
b
a
Lumbar Spine Mini Sled Tests• Lumbar kinematics to replicate loading level seen in a vehicle test• Initial Position reference for FEA established via Laser scanning.• Validation based on 2 independent sets of signals.a. Ballast Acceleration & Angular velocity outputs.b. Lumbar Spine Loadcell Forces & Moments.
©2019 Confidential & Proprietary
20
Ballast Kinematics angular velocity: 6 m/s (with Cable)
Lumbar Spine Mini Sled Tests
TestV1.2
©2019 Confidential & Proprietary
21
Loadcell loads: 6 m/s (with Cable)
Lumbar Spine Mini Sled Tests
TestV1.2
©2019 Confidential & Proprietary
22
Motivation for additional testing:1. Abdomen stiffness is an important parameter which affects the kinematics of upper torso flexion, chin to
chest contact & Neck Fz;
2. CAE customers reported that the abdomen material is very stiff and leads to over-prediction of the Upper Neck Fz forces;
3. Humanetics proposed an interim solution by validating the abdomen insert using the TU-B sled setup;
4. The next step is to validate the Abdomen using a drop test setup.
Stiffer AbdomenTuned (softer) Abdomen
Upper Neck Force-Z
Abdomen Insert
Abdomen Foam Drop Tests
©2019 Confidential & Proprietary
23
• Component level tests with isolated the abdomen;• Total of 27 tests were executed at multiple speeds;• Hardware variability-three test subjects.
Drop Tower Setup
Impactvelocity
Abdomen 1 (EJ4177)
Abdomen 2(DY 7779)
Abdomen 3(Q10-10001)
1.55 m/s
Test 1 √ √ √
Test 2 √ √ √
Test 3 √ √ √
2.51 m/s
Test 1 √ √ √
Test 2 √ √ √
Test 3 √ √ √
3.38 m/s
Test 1 √ √ √
Test 2 √ √ √
Test 3 √ √ √
Abdomen Foam Drop Tests
©2019 Confidential & Proprietary
24
Abdomen Foam Drop Tests (without skin)
Drop speed: 1.55m/s2.51 m/s3.38 m/s
TestV1.1V1.2
©2019 Confidential & Proprietary
25
Abdomen Foam Drop Tests (with skin)
Drop speed: 1.55m/s2.51 m/s3.38 m/s
TestV1.1V1.2
©2019 Confidential & Proprietary
26
• APTS (Abdomen Pressure Twin Sensor) are used for Abdomen injury assessment. Injury criteria are under ECE regulation R129. The sensor is used in the Q family dummies and THOR family dummies;
• Earlier beta version sensor model released in December 2016;• Further work planned for the sensor validation based on component
testing
APTS sensor FE model development
©2019 Confidential & Proprietary
27
• Sensor validation based on Component Tests – multiple speeds
APTS 50 mm test @ 0.74 m/stest @ 1.13 m/sFE in Red
• Peak pressure (bar) values/timing profile of the sensormatch with the validation domain of the ECE-R129legislation requirements.
APTS sensor FE model development
©2019 Confidential & Proprietary
28
• FE data validation based ono Thorax repeat tests at multiple speeds.o Use high-speed videos for kinematic correlation.o Total of 40 dummy channels used for FE/test correlation.o Positioning reference-Tilt sensors and laser pendulum alignment
Full Dummy Validations: Thorax Frontal Impact
Tilt sensor outputs
©2019 Confidential & Proprietary
29
Tilt sensor outputs
Full Dummy Validations: Thorax Lateral Impact• FE data validation based on
o Thorax repeat tests at multiple speeds.o Use high-speed videos for kinematic correlation.o Total of 40 dummy channels used for FE/test correlation.o Positioning reference-Tilt sensors and laser pendulum alignment
©2019 Confidential & Proprietary
30
Tilt sensor outputs
• FE data validation based ono Pelvis repeat tests at multiple speedso Use high-speed videos for kinematic correlationo Total of 40 dummy channels used for FE/test correlationo Positioning reference-Tilt sensors and laser alignment of pendulum
Full Dummy Validations: Pelvis Lateral Impact
©2019 Confidential & Proprietary
31
A major update release of Q10 Euro NCAP 2020 dummy FE model v1.2 is scheduled for September 2019.
Additional component validations – Abdomen/Neck/Lumbar Spine/APTSFull body validations – Thorax/Pelvis/Abdomen/FemurAddress customer feedbacksMeet Euro NCAP 2020 specifications
In Summary
MK-FO-00036C, Rev A
Thank you for your attention
Acknowledges: Q10 Euro NCAP 2020 FE model development team members
Renuka JagadishVinit Manjarekar
Apoorva Lakshminarayana