COM-02-039-4/''N Revision 0
-( ) May 1983'' 64.305.2103
QUAD CITIES NUCLEARPOWER STATION
UNITS 1 AND 2
PLANT UNIQUE ANALYSIS REPORTVOLUME 4
INTERNAL STRUCTURES ANALYSIS
Prepared for:
Commonwealth Edison Company
'''N Prepared by:
s- - NUTECH Engineers, Inc.
San Jose, California
Approved by:
AVV k
D. O. Talbott I. D. McInnes, P . E.
Project Leader Engineering Manager
h
R. H. Adams, P.E.Engineering Director
.
Issued by:
$ LLC --
-
/''N, A. K. Moonka, P.E. R. H. Buchholz
(b) Project Manager Project Director
' ).8307180158 830627 n
E8PDR ADOCK 05000237P PDR
_ _ _ _ _
I
REVISION CONTROL SHEET
,O Quad Cities Nuclear Power Station, REPORT NUMBER: COM-02-039-4
V)LEl Units 1 and 2 Revision 0Plant Unique Analysis Report I
Volume 4i
I. D. McInnes/ Engineering Manager IMINITIALS
D. C. Talbott/ Consultant I [[INITIALS
'
M. D. Pratt/ Engineering Analyst
7[ITIALS
R. Fernandez/ Consultant II hINITIALS
C. T. Shyy/ Senior Engineer DIE,
,
INITIALS
'N( /'O
INITIAL 5
INITIALS,
I.PAGE(S)C- ~
PRE- ACCURACY CRITERIAgg REV- A I ^
A ED CHECK CHECK PARED CHECK CHECKPAGE (S )
g ID4-1i{ A7 N/A 4-3.1 00
| 4-1.1- g7 IM4-1.5;
| | :15 M F '*
| 4-2.16 f8([ W4-2.17 [[ 6G j
'I# Ib !4-2.18 $#" M I-d-2.190 AT M lh 0 i-2.9n
QEP-001.4-00
4-ii l
nutggh
. -
ABSTRACT4
The primary containments for the Quad Cities Nuclear Power
j Station Units 1 and 2 were designed, erected, pressure-tested,
and N-stamped in accordance with the ASME Boiler and Pressure
Vessel Code, Section III, 1965 Edition with addenda up to and
including Summer 1965 for the Commonwealth Edison Company (CECO)by the Chicago Bridge and Iron Company. Since then, newrequirements have been established. These requirements affect
the design and operation of the primary containment system andare defined in the Nuclear Regulatory Commission's (NRC) SafetyEvaluation Report, NUREG-0661. This report provides anassessment of containment design loads postulated to occurduring a loss-of-coolant accident or a safety relief valvedischarge event. In addition, it provides an assessment of the
effects that the postulated events have on containment systems4
operation.
This plant unique analysis report (PUAR) documents the efforts
h undertaken to address and resolve each of the applicableNUREG-0661 requirements. It demonstrates that the design of the
primary containment system is adequate and that original designsafety margins have been restored, in accordance with NUREG-0661acceptance criteria. The Quad Cities Units 1 and 2 PUAR iscomposed of the following seven volumes:
o Volume 1 - GENERAL CRITERIA AND LOADS METHODOLOGYo Volume 2 - SUPPRESSION CHAMBER ANALYSIS
'
o Volume 3 - VENT SYSTEM ANALYSISo Volume 4 - INTERNAL STRUCTURES ANALYSISo Volume 5 - SAFETY RELIEF VALVE DISCHARGE LINE
PIPING ANALYSIS
p)i COM-02-039-4
'
Revision 0 4-iii
1
nutggb i
. . . . . ..
~ --_ - _ _ - -- .- __.
I
o Volume 6 - TORUS ATTACHED PIPING AND SUPPRESSION
h CHAMBER PENETRATION ANALYSES (OUAD'
L CITIES UNIT 1)o Volume 7 - TORUS ATTACHED PIPING AND SUPPRESSION
CHAMBER PENETRATION ANALYSES (QUAD
-CITIES UNIT 2)
This volubte documents the evaluation of the suppression chamber
internal structures. Volumes 1 through 4 and 6 and 7 have been,
prepared by NUTECH Engineers, Incorporated (NUTECH), acting asan agent to the Commonwealth Edison Company. Volume 5 has been
prepared by Sargent and Lundy, who performed the safety relief
valve discharge line (SRVDL) piping analysis. Volume 5
describes the methodology and procedures used in the SRVDL
piping analysis.
4
i
'
.
4
|
1
4
I
ii
!'
:!
f| COM-02-039-4 l
Revision 0 4-iv
M ..
-_ . _ _ . . _ _ __ . . -
- - - . . . . - - ._. .- - - _-.
.
TABLE OF CONTENTS'
Page
ABSTRACT 4-lii
LIST OF ACRONYMS 4-vi
LIST OF TABLES 4-vii
LIST OF FIGURES 4-vili
4-1.0 INTRODUCTION 4-1.1>
4-1.1 Scope of Analysis 4-1.2,
4-1.2 Summary and Conclusions 4-1.4
'4-2.0 INTERNAL STRUCTURES ANALYSIS 4-2.1
4-2.1 Component Description 4-2.2
4-2.1.1 Catwalk 4-2.3
4-2.1.2 Electrical Conduits 4-2.81
4-2.2 Loads and Load Combinations 4-2.9
4-2.2.1 Loads 4-2.10
4-2.2.2 Load Combinations 4-2.13
4-2.3 Acceptance Criteria 4-2.15
4-2.4 Methods of Analysis 4-2.16
4-2.5 Analysis Results 4-2,17P
4-2.5.1 Closure 4-2.20
4-3.0 LIST OF REFERENCES 4-3.1. .
|
|
|'
-~
,j COM-02-039-4'
Revision 0 4-v
1
'L nutggb
. - -- ._ .. . _ . --. - _ _ _ _ . ._ . - -
. . . . .. _ . . . . _. . . _
h
;
! LIST OP' ACRONYMS
'
ASME American Society of Mechanical EngineersCO Condensation oscillation
DBA Design Basis Accident
ECCS Emergency Core Cooling System |
IBA Intermediate Break Accident
IR Inside Radius
LDR Load Definition Report
LOCA Loss-of-Coolant Accident
NRC Nuclear Regulatory CommissionNVB Non-Vent Bay
OBE Operating Basis Earthquakei
PUAAG Plant Unique Analysis Applications Guide
PUAR Plant Unique Analysis Report
PULD Plant Unique Load Definition
SRV Safety Relief Valve
SSE Safe Shutdown Earthquake
O VB Vent Line Bay
-
4
COM-02-039-4'( Revision 0 4-vi
._ .
- _ . . - . - . . . . . - . . . . - . . . - _ . . - . . . - - . _ . . .- . - = - ..- . - --
1
F
r5
ij LIST OF TABLES
r4
Number Title Page i
t
4-2.2-1 Internal Structures Component Loading 4-2.12
i Identification.
;-
; 4-2.2-2 Internal Structures Controlling Load 4-2.14! Combinationsi
4-2.5-1 Catwalk Stresses for Controlling Load 4-2.18 ,
Combinations
! 4-2.5-2 Maximum Suppression Chamber Shell 4-2.19Stresses at Catwalk Reinforcement Beam;
| Locationsi
.
!(
!;
|r.
i
l
i !t i
'
li!
!
!|i
(l
,
|
|-
!- COM-02-039-4-' Revision 0 4-vil
- . - - . - - - - - - - _ . --
_ . . . _ . _ _ _ _ . _ _ _ _ - _ _ . _ . . _ _ _ . _ _ . . . _ _ . . . . _ . _ _ . _ _ _ _ _ _ _ . _ _ . _ . _ . . _ . _ . - _-
LIST OF FIGURES
i
. Number Title Page
4-2.1-1 Plan View of Suppression Chamber Internal 4-2.5Catwalk
4-2.1-2 Suppression Chamber Internal Catwalk-Typical Support at Miter Joint 4-2.6
,-
I
4-2.1-3 Suppression Chamber Internal Catwalk- '
'
! Typical Support Between Miter Joints 4-2.7
!
id
:,
-
j;
,
E
a
:1
| !
:,
P
'
ii
4
4
4-
i
.
COM-02-039-4_ Revision 0 4-viii
,
,
_ __ _ . _ . _ _ _ _ . _ _ _ _ _ . _ _ _ _ _
.. - .. .. . - . _ . . . _ . .- - _ . -
4-1.0 INTRODUCTION,
In conjunction with volume 1 of the Plant Unique
Analysis Report (PUAR), this volume documents the
efforts undertaken to address the requirements defined
in NUREG-0661 (Reference 1) which affect the Ouad
Cities Units 1 and 2 internal structures. The internal
structures PUAR is organized as follows:,
o INTRODUCTION
Scope of Analysis-
Summary and Conclusions-
o INTERNAL STRUCTURES ANALYSIS (Catwalk and
Electrical Conduits)
; - Component Description
Loads and Load Combinations-
;
- Acceptance Criteria
Methods of Analysis-
Analysis Results-
!The INTRODUCTION section contains a general overview 1
discussion of the internal structures evaluation. The
INTERNAL STRUCTURES ANALYSIS section discusses the
specific components, loads,- criteria, methods, and~
Lresults associated with the evaluation.
'\-- COM-02-039-4| Revision 0 4-1.1
. . .. . . - . . . .
4-1.1 Scope of Analysis
OThe criteria presented in Volume 1 are used as the
basis for all of the Quad Cities Units 1 and 2 internalstructures evaluations described in this volume. The
internal structures evaluated are the catwalk and
electrical conduits. These structures are not required
for the safe operation of the primary containment*
system during accident conditions.
These internal structures are evaluated for the effectsof loss-of-coolant accident (LOCA) and safety relief
valve (SRV) discharge-related loads, as defined by the
Nuclear Regulatory Commission's (NRC) Safety Evbluation
Report, NUREG-0661, and the " Mark I Containment Program
Load Definition Report" (LDR) (Reference 2).
The LOCA and SRV discharge loads used in this evalua-
tion are formulated using the procedures discussed in
Volume 1 of this report. The evaluation includes a
structural analysis of the internal structures to
ensure that these structures do not fail and result in
damage to safety-related components.
||
COM-02-039-4Revision 0 4-1.2
nutggh
. .. _ . _ _ _ . . _ - _ _ _ __ _ . _ _ _ - . . _ _ _ _ _ _ . _ .. ___._
i
The results of the structural evaluation for each load
are used to evaluate load combinations for the internal
structures in accordance with the " Mark I Containment
Program Plant Unique Analysis Application Guide"*
(PUAAG) (Reference 3). The evaluation results are
conservatively compared with the -acceptance limits
specified by the applicable sections of the American
Society of Mechanical Engineers (ASME) Code (Reference
4) to ensure that safety-related components are not
adversely affected.
i
Other internal structures evaluated were the vent line
drain, thermowells, and the emergency core cooling
system (ECCS) suction strainers. They are described in
! Sections 2 -2 .1, 3 -2 .1, 6-2.1, and 7-2.1, respectively,i
:
4
,
,
|
COM-02-039-4Revision 0 4-1.3
'
.
- _. . .. . . - - . - - - . .- -. . .. .
:
4-1.2 Summary and Conclusions |
OThe evaluation documented in this volume is performed
for the Quad Cities Units 1 and 2 internal structures
identified in Section 1-1.1 and described in Section
1-2.1. These structures are the catwalk and electrical
conduits.
The LOCA and SRV discharge-related events defined in
NUREG-0661 result in hydrodynamic loadings on the
internal structures. The major loadings which affect
the catwalk and ele 6trical conduits above the
suppression pool include pool swell impact and drag
loads, froth impingement loads, and pool fallback
loads. The major loadings which affect submerged
portions of the catwalk include submerged structure
loadings. Conservative values for these loadings are
developed using the methodology discussed in Section
1-4.0. Other loads such as dead weight and seismic
loads have a lesser effect on the internal structures,
| but are also considered in the evaluation.
|
|
||
||
|
||
l
|
COM-02-039-4Revision 0 4-1.4
nute_cb
. _ . _ . _ . - . . - . . ~ - . .. _. -- .. . = - - . . . ._
fv
The analysis results for these loadings are used to
b '
V formulate the controlling event combinations which*
affect the internal structures, as discussed in Section,
1-3.2. The results are compared to acceptance limitsi
which ensure that the internal ' structures do not failand result in damage to safety-related components. The
.
| evaluation results show that the stresses for all of;
I the internal structures are within acceptable limits.,
The NUREG-0661 requirements are therefore considered to'
be met.ii
!
i
i
4,
1 .
i
I
4
1
1
i
i
!
.
.COM-02-039-4'
Revision 0 4-1.5!
_.. .. . . . _ _ - . - - . - . _ . . ~ _ . . . . . . . _ , . - . _ _ . . . _ . . . . _ . - . . _ _ . _ , . . . - . . _ _ - . . . . .-
. _ . -. .. . _ _ .
INTERNAL STRUCTURES ANALYSISO 4-2.0
An evaluation of each of the NUREG-0661 requirements
which affect the design adequacy of the Quad Cities
Units 1 and 2 internal stru'ctures is presented in the
following sections. The criteria used in the
evaluation are contained in Volume 1 of this report.
The internal structures components which are examined
are described in Section 4-2.1. The loads and load
combinations which are evaluated are described andi
presented in Section 4-2.2. The acceptance limits to
I which the analysis results are compared are discussed
and presented - in Section 4-2.3. The analysis method-, .
ology used to evaluate the effects of these loads and
load combinations is discussed in Section 4-2.4. The,
analysis results and the corresponding design margins
are presented in Section 4-2.5.~
j
|
I:
i.
O -COM-02-039-4| v
Revision 0 4-2.1
*
.. . ., . , . , . . . , - . . . , , , , . , , . . . . , , , . - , . . , - , . . . - , . . , . .-
||
|
|| 4-2.1 Component Description
OThe internal structures which are evaluated include thecatwalk and electrical conduits, which are described in'
Sections 4-2.1.1 and 4-2.1.2, respectively.
!
:I
i|
[
i
O
|
|
COM-02-039-4| Revision 0 4-2.2
.
nutggb- .. - . - _ -
_
fG 4-2.1.1 Catwalk). .
The catwalk is a platform-type structure approximately
three feet wide, which extends around the full
The 'atwalkcircumference of the suppression chamber. c
is located in the upper outside quadrant of each
suppression chamber mitered cylinder.
The catwalk frame consists of two C9 x 13.4 stringers,
which extend from ring girder to ring girder. The
catwalk frame is supported at two intermediate
locations between ring girders in the non-vent line
bays (NVB) and at one intermediate location in the vent,
O line bays (VB) (Figure 4-2.1-1). The supports at theg,
ring girders consist of a W12 x 136 horizontal support
beam attached to a 6" XXS vertical pipe column (Figure
4-2.1-2). The intermediate supports consist of a*
W16 x 36 horizontal support beam attached to a 4",
Schedule 120, vertical pipe strut. The pipe strut
connects to a reinforcement beam which distributes the
pipe strut forces to the suppre'ssion chamber shell
(Figure 4-2.1-3).
| The catwalk platform consists of grating that spans the
|stringers. The grating is attached to the stringers by
; ON -
COM-02-039-4Revision'O 4-2.3
$
. . . . ..
intermittent welds. Additional hold-down support is
provided by L3 x 2 x 3/8 hold-down angles that are'
bolted to the stringers. The catwalk stringers are
braced against lateral loads by: L3 x 3x 1/4 angles
placed between stringer pairs, the same size angles
placed between the stringers and the ring girder, and
the horizontal support members at the ring girders
(Figure 4-2.1-1).
O
l
1
l|
|
COM-02-039-4Revision 0 4-2.4
nutggb.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -
OINTERMEDIATE j
- / SUPPCRT
C9 x 13.4 si
STRINGER -'
SUPPRESSION / '( T LINEER
'===== | |\
e# [qMITERJCINT'A -
,
%s== \1^#,,>
bh5 QN 5 EIIO OIEEEI
k- _ _I .__ ..-
N '"5 8
( NON-VENT- -
INTE3MEDIATgd-
| I.INE SAY"
SUPPCRTS 3'-11 1 /2"
O-(TYP)
. W. ->
'- : i .
... S. m.,
CF CONTAINMENT
GRATINGd \ ,,,.
-f \.- ,
.' $ '~ | '
\
|t
1. SEE FIGURE 4-2.1-2 FOR SECTION A-A.2. SEE FIGURE 4-2.1-3 FOR SECTION B-B.
Figure 4-2.1-1
PLAN VIEW OF SUPPRESSION CHAMBERl INTERNAL CATWALK
COM-02-039-4Revision 0 4-2.5
nutggb- - - - - - _ _ - - - - ----
.
C CATWALK q SUPPRESSION j
CHAMBER-
I
3 X 2 X 3/8gggg7g GRATING HOLD
DCWN ANGLESo ,
i
C9 x 13.4STRINGERS,
3/4" THICK,,
PLATE |
{ y W12 x 136
c, i,
_ _l -t_
,
O
RINGGIRDER
6" DIA PIPE
1" THICK PLATE
SUPPRESSIONCHAMBER SHELL ---
13'-2 1/2" IR
1
'15'-0" 1R
SECTION A-A(FROM FIGURE 4-2.1-1)
Figure 4-2.1-2
SUPPRESSION CHAMBER INTERNAL CATWALK -
TYPICAL SUPPORT AT MITER JOINT
COM-02-039-4| Revision 0 4-2.6
nutggh
-. _. -
|
|
||
O't q SUPPRESSIONCHAMBER I
g!
S4'-6" TO q )CT CONTAINMENT
' SUPPRESSIONCHAMBER SHELL
15'-0"REINFORCEMENT IRBEAM
'( CATWALK
'8'-4 7/16" ;
VENT LINE BAY,
t | -
=': '
,8'-6"
_
~
NON-VENT LINE BAY,'
.
.
i HANDRAIL i
4" DIA ' C9 X 13.4PIPE | J STRINGER_ g
_a' | 'l
,
W16 X 36'
, s .
j, 4 -Q
l
10'-10"
SECTION B-B(FROM FIGURE 4-2.1-1)
Figure 4-2.1-3
SUPPRESSION CHAMBER INTERNAL CATWALK -
TYPICAL SUPPORT BETWEEN MITER JOINTS
'COM-02-039-4Revision 0 4-2.7
-- .
,.
_ _ _ .
.
4-2.1.2 Electrical Conduits eThe vacuum breaker conduits provide power and circuitry
for solenoids and instrumentation located on the
drywell/wetwell vacuum breakers. The instrumentation
is used to monitor the valve open and closed positions
during start-up testing. The wiring for the vacuum
breaker electrical system is routed inside 2" and 3"
diameter rigid steel conduit from two suppression
chamber penetration locations to each vacuum breaker.
The conduits are attached to horizontal members
attached to the bottom of the catwalk stringers and to
short, vertical membere that are welded to the web of
the catwalk stringers. Junction boxes at the
connection and termination points of the conduit are
also supported on short, vertical members that are
welded to the web of the stringers.
COM-02-039-4Revision 0 4-2.8
nutggb1
. - - _ _ ---_-__-_-____--______________u_
, . - - - _. _ _. . - _ __ _ . _ _ _ . _ _ -- . _ ___
, .
4
1 -
;
( 4-2.2 Loads and Load Combinations j.
,
The loads for which the Ouad Cities Units 1 and 2
internal structures are evaluated are defined in
NUREG-0661 on a generic basis for all Mark I plants.
The methodology used to develop plant unique loads forr
each applicable load defined in NUREG-0661 is discussed'
>
in Section 1-4.0. The results of applying the
i methodology to develop specific values for each of the:
y
j controlling loads are discussed and presented in
i Section 4-2.2.1. ;
1;
1
i The controlling load combinations which affect thei
! internal structures are formulated by usincj the event ,
combinations and event sequencing defined in NUREG-0661
and discussed in Sections 1-3.2 and 1-4.3. The.
controlling load combinations are discussed and1
"
. presented in Section 4-2.2.2.
ii
:i
i
(,
i
.
l |COM-02-039-4> Revision 0- 4-2.9 ;
<
.
- - -, ,. -,. , . , . - , . - ,an,,v---- , , , -- . ,n, +m, .n,-,,,n .-.-ev,e-,cea,-,. ,,,,,-m-- ,,,--,ver--nm-
1
1
!4-2.2.1 Loads
OThe loads acting on the internal structures are
categorized as follows:
.
1. Dead Weight Loads
a. Dead Weight of Steel
'
2. Seismic Loads
a. Operating Basis Earthquake (OBE)
b. Safe Shutdown Earthquake (SSE)
3. Pool Swell Loads
a. Pool Swell Impact and Drag
b. Froth Impingement and Fallback
c. Pool Fallback
d. LOCA Bubole-Induced Drag on Submerged
Structures
4. Condensation Oscillation (CO) Loads
a. Design Basis Accident (DBA) CO Drag on
Submerged Structures
b. Intermediate Break Accident (IBA) CO Drag
on Submerged Structures
5. Chugging Loads
a. Pre-Chug Drag on Submerged Structures
b. Post-Chug Drag on Submerged Structures
COM-02-039-4Revision 0 4-2.10
nutggb
. . -. _ ._ - - _ _. . - _ . ._- . - . - - -_- ._- _ _ __. --- ._- . ..._ -
.
6. Safety Relief Valve Discharge Loads
i a. SRV Discharge Bubble-Induced Drag on
Submerged Structures
:
j 7. Containment Interaction Loads:
a. Suppression Chamber Motions
Table 4-2.2-1 shows the specific loads that affect the,
catwalk an6 conduit. The methodology used to develop
values for each of these. loadings is discussed in
Section 1-4.0. The resulting magnitudes and.
characteristics of each loading are similar to those
described in Volumes 2 and 3 of this report.i
i
t'I
i
!
4
4
4
!
|
|
| !
(_
COM-02-039-4l, t Revision.0 4-2.I1
I M ;
e--*-Ju- ' _ N em- = 49-9m e e e p a-ge*1 e w- g-mw-w w -F -t--* grsqT ww-'Te '- v &y m er--ap r-w'-*gw**- **mim eta,-mmwe--1 9-ywweMe-- q p wFrr+a -e-$ -y,W---777$
. .
*
Table 4-2.2-1.
INTERNAL STRUCTURES
COMPONENT LOADING IDENTIFICATION
.
VOLUME 4 LOADDESIGNATION PUAR VOLUMEELECTRICAL
SECTIONCATWALK CONDUITSREFERENCE
CATEG'ORY N MBER
DEAD WEIGHT la X X 1-3.1
2a X X l-3.1
SEISMIC2b X X l-3.1
3a X X l-4.1.4.2
3b X l-4.1.4.3POOL SWELL
LOADS3c X X l-4.1.4.4
3d X (1) 1-4.1.6
4a X(1) 1-4.1.7.3CONDENSATIONOSCILLATION
4b X (1) 1-4.1.7.3
Sa X(1) 1-4.1.8.3
CHUGGINGSb X (1) 1-4.1.8.3
6a X W 1-4.2.4DISCH RGE
CONTAINMENT 7a X VOLUME 2INTERACTION
(1) APPLIES TO SUPPORT COLUMN AT THE RING GIRDER ONLY.
O! COM-02-039-4
Revision 0 4-2.12
nutggh._ . .
_ -- . - -- . _ _ - - ._.
A
4-2.2.2 Load Combinations
'
The loadings which affect each of the internal struc-
tures are presented in Section 4-2.2.1. The general
NUREG-0661 criteria for grouping these loads into event
combinations are discussed in Section 1-3.2. Since the
electrical conduits and a majority of the internal
catwalk components are located above or below the
suppression pool, the event combinations which produce
controlling stresses are those which contain pool swell
and SRV discharge loads.
The submerged portions of the catwalk supports are
s subjected to LOCA air clearing, condensation
oscillation, chugging, and SRV discharge submerged
structure loads identified in Section 1-4.0. The:
catwalk is evaluated for two controlling combinations.
These are the IBA 15 and the DBA 25 combinations as;
described in the PUAAG (Table 4-2.2-2). The electrical
conduits and junction boxes are evaluated for the
controlling DBA 25 combination, since the pool swell
j load is the dominant load on these components.
|
:
| COM-02-039-4 (gRevision 0 4-2.13
!!
;- - - - .- _ - - , ~ _ _ . . , _ . , .,. _ _, _ __.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _. _ _ _ _ _ _ _ _ _
f
Table 4-2.2-2
INTERNAL STRUCTURES CONTROLLING LOAD COMBINATIONS
f
LOAD COMBINATION
LOAD DESIGNATION ( }15(2) 25(2)
DEAD WEIGHT 1 1
OPERATING BASIS EARTHQUAKESEISMIC
SAFE SHUTDOWN EARTHQUAKE 2b 2b
POOL SWELL 3a-3d
CONDENSATION OSCILLATION (3) 4b
CHUGGING (3) Sa-Sb-
SRV DISCHARGE (3) 6 6
CONTAINMENT INTERACTION 7 7
TORUS"
SERVICE LEVEL AT WHICHSTRESSES ARE EVALUATED CATWALK AND
ELECTRICAL E( ) E(CONDUITS
(1) SEE PUAR SECTION 4-2.2.1.
(2) SEE NUREG-0661.
(3) SUBMERGED STRUCTURE LOADINGS ONLY AFFECT SUBMERGEDPORTIONS OF CATWALK COLUMN SUPPORTS.
(4) THE CONTROLLING LOAD COMBINATION FOR THE TORUS SHELLAT CATWALK ATTACHMENT LOCATIONS IS THE DBA 18COMBINATION AS DESCRIBED IN REFERENCE 3.
(5) THE CATWALK IS CONSERVATIVELY ANALYZED TOSERVICE LEVEL D LIMITS.
COM-02-039-4Revision 0 4-2.14
nutggh- _ _ - - - - - - -
. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
O 4-2.3 Acceptance Criteria
U)8
Table 4-2.2-2 shows the service level assignments for
the internal structures and the suppression chamber
shell at attachment points to internal structures. The
table shows that the catwalk and electrical conduits
are designated as Service Level E components, and as
such, are not required to meet ASME Code acceptance
-
limits. In order to employ a consistent set of design
criteria which ensures that failure will not occur, the
catwalk is conservatively evaluated for the Service
Level D acceptance limits contained in the ASME Code.
The suppression chamber shell near attachment points to ,
'
internal structures is evaluated in accordance with the
requirements for Class MC components contained in the
ASME Code. The corresponding allowable stresses of the
catwalk components for the controlling combination arei
presented in Section 4-2.5. The electrical conduits
are evaluated to ensure that they will not impeir the
function of safety-related components.
t )v COM-02-039-4Revision 0 4-2.15
1
i
4-2.4 Methods of Analysis ' '
OThe loadings for which the internal structures are
evaluated are identified in section 4-2.2.1.
The analysis of the catwalk is performed using manual
calculations. An equivalent static analysis is per-
formed for all catwalk loadings except for containment
interaction and pool swell loads, for which transient
analysis is performed. The transient analysis of the
catwalk is performed using a beam finite element model
which includes the stringers, hangers, and associated
catwalk components. The reaction loads from the
catwalk pipe strut to the suppression chamber are
obtained from the bounding load combination for the
attachment point. The results from a unit load case on
a finite element model composed of plate elements,
which represents a 90' section of the suppression
chamber shell and the reinforcement beam, are factored
by the reaction loads from the catwalk. The resulting
stresses in the suppression chamber shell are combined
I with the stresses obtained from the suppression chamber
analysis to evaluate local stresses in the suppression
chamber shell. Volume 2 of this PUAR describes the
suppression chamber analysis and the general state of
stress in the suppression chamber shell.
OCOM-02-039-4Revision 0 4-2.16
nutgsb
. - . .. .. . _ . . -- .- . . . . - - - _ _ _ _ . ._
!,
+
a
4-2.5 Analysis Results
.
The geometry, loads, load combinations, acceptance
criteria, and analysis methods used in the evaluation
of the internal structures are presented in the -
preceding sections. Table 4-2.5-1 shows the resulting
maximum stresses for the catwalk for the controlling
load combination. This table shows that the calculated
stresses for these components are less than the
corresponding allowable stresses. Table 4-2.5-2 shows
I the state of stress in the suppression chamber shell at'
the catwalk reinforcement beam locations. ,
i
The results of the electrical conduit supports and
junction boxes confirm that the conduits will not
impair the functions of safety-related components.
,
,
| '
!C!\ COM-02-039-4
Revision 0 4-2.17
- . - ._ . _ _ .- . - -
1
|
|
Table 4-2.5-1
CATWALK STRESSES FOR CONTROLLING LOAD COMBINATIONSl
LOAD COMBINATION STRESSES (ksi)
MATERIAL BEAM DBA 25ITEM MATERIAL PROPERTIES STRESS
OALCULATED( E Bu CALCULATED (1)3 3gSTRESS ALLOWABLE(SERVICE IEVEL D)
SHEAR 2.56 12.84(2)ASTM 8 = 36.0(2)
STRINGER y *
A-36 3 . $g,o BENDING 37.97 43.20(2)
32*1 SHEAR 0.76 25.68SUPPORT S =BEAM AT ASTM y 0.04
58.0MITER A-36 S =u BENDING 1.87 42.38JOINT-
8 P T COMPRESSIVE 1.25 30.00ASME 3 , 3g,yCO g 0.07A*
AT MITER S = 60.0GRADE 6 u BENDING 1.22 41,18JOINT
SHEAR 7.27 25.6832.1INTERMEDIATE ASTM S =
# **'SUPPORT BEAM A-36 S 58.0=
u BENDING 19.09 38.65
COMPRESSIVE 9.89 27.52ASTM S = 26.7INTERMEDIATE 0.63A"333PIPE STRUT S = $5.0GRADE 6 u BENDING 8.86 . 35,24
II III36.0 COMPRESSIVE 14.91 28.00S =
ANGLE ASTM y 0.86BRACING A-36 S = 58.0 IIU BENDING 13.31 43.20
(1) VALUES SHOWN ARE OBTAINED FROM BEAM INTERACTION EQUATION.(2) VALUES CONSIDERE., ARE FOR ACTUAL TEMPERATURE.
(3) TIME PHASING OF THE RESPONSE IS NOT CONSIDERED. THE PEAK-TO-PEAKVALUES ARE CONSERVATIVELY USED.
i
||
|
|
COM-02-039-4Revision 0 4-2.18
nutgg])
._
Table 4-2.5-2k'
MAXIMUM SUPPRESSION CHAMBER SHELL STRESSES AT
CATWALK REINFORCEMENT BEAM LOCATIONS
STRESS CALCULATED CALCULATEDTYPE STRESS (ksi) ALLOWABLE
PRIMARY11.94 0.41MEMBRANE
LOCAL PRIMARY 28.46 0.98MEMBPANE
PRIMARY +SECONDARY 52.32 0.75
STRESS RANGE
I
Q' COM-02-039-4Revision 0 4-2.19
nutagh-. . ..
i
|1
.
4-2.5.1 Closure
The values of the loads used to evaluate the internalstructures are conservative estimates of the loads
postulated to occur during an actual LOCA or SRV
discharge event. The event combinations for which theinternal structures are evaluated envelop the actual
events expected to occur during a LOCA or SRV discharge
event.
The acceptance limits to which the evaluation results
are compared are more restrictive than those required
by NUREG-0661. Use of these acceptance limits ensures
that the internal structures will not fail and cause
damage to safety-related components.
The analysis results presented show that stresses in
the internal structure components are within these
conservative acceptance limits. The NUREG-0661
criteria are therefore considered to be met,
l
|
COM-02-039-4Revision 0 4-2.20 .
nutggh
4-3.0 LIST OF REFERENCES
1. " Mark I Containment Long-Term Program," SafetyEvaluation Report, U SN RC , NUREG-0661, July 1980;Supplement 1, August 1982.
2. " Mark I Containment Program Load DefinitionReport," General Electric Company, NEDO-21888,Revision 2, November 1981.
3. " Mark I Containment Program Structural AcceptanceCriteria Plant Unique Analysis Application Guide,"Task Number 3.1.3, Mark I owners Group, GeneralElectric Company, NEDO-2 4 583, Revision 1, October1979.
4. ASME Boiler and Pressure Vessel Code, Section III,Division 1, 1977 Edition with Addenda up to andincluding Summer 1977.
O
!
\ COM-02-039-4Revision 0 4-3.1
|s
|
|
nutg_qh
t
- . - - _ - _ _ _ - . - __ - - - - _ -- .
e QUAD CITIES STATIONUNITS 1 & 2 '
,
I
i
MARK I PLANT UNIQUE|
| ANALYSIS REPORT |: i
'
i
:
O VOLUME 5
O|
MM NWEALTH E IS N MPANYOSARGENT&LUNDY
.. . .....
1
- _ - _ _ _ . - . - . - - - - - . . - . . - _ . , - . . - , - - . _ - . - _ _ , . - . - . _ _ . , _ _ .