Quick-Start Guide Properly Orient the Connectors Connecting the J5300 to SAS-3 RAID Controllers Security Analytics appliances that have two RAID controllers can support up to three storage modules per RAID controller. Attach the storage modules to the head unit in the order shown below, using SAS-3 to SAS-3 cables: Attach the Rail to the Front Post and Secure the Enclosure to the Rack a. Extend the rail to the front post and insert the studs into the corresponding mounting posts. b. Use the rail screws to anchor the rail to the front post. c. After verifying that the rails are aligned, secure, and stable, place the enclosure on the rails. d. Insert the screws through the mounting holes on either side of the enclosure and then secure them with the cage nuts. e. Replace the drives in the enclosure. Connecting a J5300 to a Single RAID Controller Security Analytics appliances that have one RAID controller can support one storage module only. For SAS-2 RAID controllers, attach the storage module to the head unit using SAS-2 to SAS-3 cables. SAS-2 RAID Controller Identify the SAS Cables Two sets of cables are included with the J5300: one set for a SAS-3 environment and another for a mixed SAS-2 and SAS-3 environment. Attach the Rail to the Rear Post a. Orient each rail so that the L-shaped shelf is at the bottom and toward the front of the rack. b. Press the spring lock on the other end of the rail, insert the studs into the holes on the rear post, and release the lock so that it grips the rail. c. Use the rail screws to anchor the rail to the rear post. 1 3 5 6 8a Unpack the Storage Module Unpack the shipment container and verify the contents of the box. Security Analytics J5300 40T Direct-Attached Storage ships with the following components: J5300 Storage Module Two SFF-8644 to SFF-8644 cables Two AC Power Cords Two SFF-8644 to SFF-8088 cables Adjustable rack-mounting rail assembly Lift/carry reminder insert Quick-Start Guide (this document) Safety and regulatory compliance inserts Prepare the Enclosure for Rack-Mounting Before installing the J5300 enclosure in the rack, perform these steps: a. Peel off the protective plastic sheet from the top and the bottom of the enclosure. b. Remove the drives from the enclosure to reduce the weight: Press the release button on each drive to unlock the drive carrier. The drive-carrier handle swings out. Grasp the handle and gently pull the drive carrier out of the J5300 and place it on a static-free surface. 2 Prepare to Install the Rails To install the J5300 enclosure into a rack with the supplied mounting rails: a. Determine where to install the enclosure—Three holes are required for the rear posts and five for the front. b. For square holes, insert a cage nut into the top mounting hole of the front posts. Insert Cage Nut Front Rail Mount Rear Rail Mount Module 5 Module 3 Module 1 Module 2 Module 4 Module 6 SAS-3 RAID Controller 2 SAS-3 RAID Controller 1 SA-J5300-DAS-40T Date of Publication: 17 March 2017 Security Analytics J5300 40T Direct-Attached Storage CAUTION: Adding storage modules is a destructive process, because all of the capture and indexing drive arrays must be reconfigured. Do not begin to add new storage to an existing system until after you have backed up all capture and indexing data. 4 SAS-3 to SAS-3 SFF-8644 to SFF-8644 SAS-2 to SAS-3 SFF-8088 to SFF-8644 Diagram Symbol Diagram Symbol 8b SAS-3 RAID Controller 7 • When attaching a SAS-3 cable to the J5300, the release pull-tab must be on the underside of the plug. You should hear a distinct click when it is seated properly. • When attaching SAS-2 or SAS-3 cables to the head unit, the release pull-tab should be on the top side of the plug.

Upload: others

Post on 18-Apr-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Quick-Start Guide: Security Analytics J5300 40T Direct

Quick-Start Guide

Properly Orient the Connectors

Connecting the J5300 to SAS-3 RAID Controllers

Security Analytics appliances that have two RAID controllers can support up to three storage modules per RAID controller. Attach the storage modules to the head unit in the order shown below, using SAS-3 to SAS-3 cables:

Attach the Rail to the Front Post and Secure the Enclosure to the Rack

a. Extend the rail to the front post and insert the studs into the corresponding mounting posts.

b. Use the rail screws to anchor the rail to the front post.

c. After verifying that the rails are aligned, secure, and stable, place the enclosure on the rails.

d. Insert the screws through the mounting holes on either side of the enclosure and then secure them with the cage nuts.

e. Replace the drives in the enclosure.

Connecting a J5300 to a Single RAID ControllerSecurity Analytics appliances that have one RAID controller can support one storage module only.

For SAS-2 RAID controllers, attach the storage module to the head unit using SAS-2 to SAS-3 cables.

SAS-2 RAID Controller

Identify the SAS Cables

Two sets of cables are included with the J5300: one set for a SAS-3 environment and another for a mixed SAS-2 and SAS-3 environment.

Attach the Rail to the Rear Post

a. Orient each rail so that the L-shaped shelf is at the bottom and toward the front of the rack.

b. Press the spring lock on the other end of the rail, insert the studs into the holes on the rear post, and release the lock so that it grips the rail.

c. Use the rail screws to anchor the rail to the rear post.

1

3

5

6

8a

Unpack the Storage Module

Unpack the shipment container and verify the contents of the box. Security Analytics J5300 40T Direct-Attached Storage ships with the following components:

• J5300 Storage Module • Two SFF-8644 to SFF-8644 cables

• Two AC Power Cords • Two SFF-8644 to SFF-8088 cables

• Adjustable rack-mounting rail assembly • Lift/carry reminder insert

• Quick-Start Guide (this document) • Safety and regulatory compliance inserts

Prepare the Enclosure for Rack-Mounting

Before installing the J5300 enclosure in the rack, perform these steps:

a. Peel off the protective plastic sheet from the top and the bottom of the enclosure.

b. Remove the drives from the enclosure to reduce the weight:

• Press the release button on each drive to unlock the drive carrier. The drive-carrier handle swings out.

• Grasp the handle and gently pull the drive carrier out of the J5300 and place it on a static-free surface.

2

Prepare to Install the Rails

To install the J5300 enclosure into a rack with the supplied mounting rails:

a. Determine where to install the enclosure—Three holes are required for the rear posts and five for the front.

b. For square holes, insert a cage nut into the top mounting hole of the front posts.

Insert Cage Nut

Front Rail MountRear Rail Mount

Module 5

Module 3

Module 1

Module 2

Module 4

Module 6

SAS-3 RAID Controller 2

SAS-3 RAID Controller 1

SA-J5300-DAS-40T Date of Publication: 17 March 2017

Security Analytics J5300 40T Direct-Attached Storage

CAUTION: Adding storage modules is a destructive process, because all of the capture and indexing drive arrays must be reconfigured. Do not begin to add new storage to an existing system until after you have backed up all capture and indexing data.

4

SAS-3 to SAS-3SFF-8644 to SFF-8644

SAS-2 to SAS-3SFF-8088 to SFF-8644

Diagram SymbolDiagram Symbol

8b

SAS-3 RAID Controller

7• When attaching a SAS-3 cable to the J5300,

the release pull-tab must be on the underside of the plug. You should hear a distinct click when it is seated properly.

• When attaching SAS-2 or SAS-3 cables to the head unit, the release pull-tab should be on the top side of the plug.

Page 2: Quick-Start Guide: Security Analytics J5300 40T Direct

© 2016 Blue Coat Systems, Inc. All rights reserved. BLUE COAT, PROXYSG, PACKETSHAPER, CACHEFLOW, INTELLIGENCECENTER, CACHEOS, CACHEPULSE, CROSSBEAM, K9, DRTR, MACH5, PACKETWISE, POLICYCENTER, PROXYAV, PROXYCLIENT, SGOS, WEBPULSE, SOLERA NETWORKS, DEEPSEE, DS APPLIANCE, SEE EVERYTHING. KNOW EVERYTHING., SECURITY EMPOWERS BUSINESS, BLUETOUCH, the Blue Coat shield, K9, and Solera Networks logos and other Blue Coat logos are registered trademarks or trademarks of Blue Coat Systems, Inc. or its affiliates in the U.S. and certain other countries. This list may not be complete, and the absence of a trademark from this list does not mean it is not a trademark of Blue Coat or that Blue Coat has stopped using the trademark. All other trademarks mentioned in this document owned by third parties are the property of their respective owners. This document is for informational purposes only. BLUE COAT MAKES NO WARRANTIES, EXPRESS, IMPLIED, OR STATUTORY, AS TO THE INFORMATION IN THIS DOCUMENT. BLUE COAT PRODUCTS, TECHNICAL SERVICES, AND ANY OTHER TECHNICAL DATA REFERENCED IN THIS DOCUMENT ARE SUBJECT TO U.S. EXPORT CONTROL AND SANCTIONS LAWS, REGULATIONS AND REQUIREMENTS, AND MAY BE SUBJECT TO EXPORT OR IMPORT REGULATIONS IN OTHER COUNTRIES. YOU AGREE TO COMPLY STRICTLY WITH

THESE LAWS, REGULATIONS AND REQUIREMENTS, AND ACKNOWLEDGE THAT YOU HAVE THE RESPONSIBILITY TO OBTAIN ANY LICENSES, PERMITS OR OTHER APPROVALS THAT MAY BE REQUIRED IN ORDER TO EXPORT, RE-EXPORT, TRANSFER IN COUNTRY OR IMPORT AFTER DELIVERY TO YOU.

Integrating the J5300 with an Existing SAS-2 Environment When adding J5300 storage modules to an existing SAS-2 system keep the following in mind:

• Adding storage modules is a destructive process: Do not begin to add new storage until after you have backed up all data.

• Contact Blue Coat support for assistance in calculating the new drive allocation.• The J5300 modules must be at the end of the chain: SAS-2 storage modules should not be placed after J5300s.

Recycling InformationRECYCLE YOUR OLD BLUE COAT APPLIANCE! — Blue Coat offers an easy and sustainable way to recycle your decommissioned Blue Coat appliances. Simply use your new shipping box to send us your old appliance, absolutely free of charge.

WHY RECYCLE? — According to the latest figures on E-Waste and Recycling from the Environmental Protection Agency (EPA), the recycling rate for electronic waste in the United States is under 20%. The remaining 80% of waste products end up in landfills or incinerators.

Without proper recycling, toxic chemicals and other hazardous materials pose serious environmental and health risks. By offering a free and easy-to-use Product Take-Back program to its customers, Blue Coat enables businesses to efficiently and responsibly dispose of their used technology. Find out how!

Fast and easy to use Use your new appliance carton to ship us your old technology.

Protects people and the planet Responsible technology recycling is good for business and the environment.

Free for our customers We cover the costs, including shipping. To take advantage of this offer, visit www.bluecoat.com/support/recycling-blue-coat-products.

Service InformationHow to Contact Support — For the current list of regional customer support contact information: www.bluecoat.com/support/technical-support/contact-service-support

When contacting Blue Coat Systems for technical phone support or to set up an RMA, be prepared to provide your serial number to verify entitlement. If you do not have your serial number, supply Blue Coat with your Support Contract Number, which can be found on your Support Contract Certificate.

BlueTouch Online — On BlueTouch Online bto.bluecoat.com you can create new technical support cases and review and comment on open cases at any time. You also have access to exclusive Blue Coat support materials, installation notes, and updates.

To obtain a BlueTouch Online login, go to: bto.bluecoat.com/requestlogin

Blue Coat Support Offerings — For a list, see www.bluecoat.com/support

United States and Canada:

Blue Coat Systems Inc. 384 Santa Trinita Ave Sunnyvale, CA 94085

Rest of the World:

Blue Coat Systems International SARL 3a Route des Arsenaux 1700 Fribourg, Switzerland

231-03280 rev D.0

8c

Module 5

Module 3

Module 1

Module 2

Module 4

Module 6

SAS-2 RAID Controller 1

SAS-2 RAID Controller 2

ResourcesFind additional resources for Security Analytics J5300 40T Direct-Attached Storage at these links:

Product Documentation BlueTouch Online: bto.bluecoat.com/documentation/All-Documents/Security Analytics

Frequently Asked Questions Blue Coat Knowledge Base: bto.bluecoat.com/knowledgebase

Blue Coat User Community Blue Coat Support Forums: forums.bluecoat.com

Classroom and Web-Based Training Blue Coat Training: www.bluecoat.com/support/training

Deployment Planning and Consultation

Blue Coat Professional Services: www.bluecoat.com/support/consulting-services

Technical Support Blue Coat Support: www.bluecoat.com/support/overview

9

Module and Power-Supply Indicators10

1 Controller Status 6 AC Power Indicator

2 Internal Use Only 7 Fault Indicator

3 Not Used 8 Not Used

4 SFF-8644 SAS Ports 9 DC Power-Supply Status

5 Power Supply On/Off Switch 10 Standby Power Indicator

1 AC Power Indicator 5 System Heartbeat

2 Global Enclosure Status 6 Drive Status

3 Controller 1 Activity 7 Drive Power/Activity

4 Controller 2 Activity

Existing SAS-2 to

SAS-2 Cabling

Front-Panel and Drive Indicators11