ram 744 - gfg instrumentationgoodforgas.com/wp-content/uploads/2013/12/ram_744... · the ram 744 is...

2
Continuous in-line CO monitor with low maintenance, dependable, long-life electrochemical sensor Three stage filtration for up to 8 users RAM 744 Autocal ® Wall Mounted or Fully Portable Compressed Air Monitoring System RAM 744 In-line CO Monitor 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 • (734) 769-0573 • www.goodforgas.com

Upload: dominh

Post on 10-Mar-2018

226 views

Category:

Documents


10 download

TRANSCRIPT

Page 1: RAM 744 - GfG Instrumentationgoodforgas.com/wp-content/uploads/2013/12/RAM_744... · The RAM 744 is the ideal monitor for Respiratory air specifications ... External alarm 90 dB at

• Continuousin-lineCOmonitorwithlowmaintenance,dependable,long-lifeelectrochemicalsensor

• Threestagefiltrationforupto8users

RAM 744 Autocal® Wall Mounted or Fully Portable Compressed Air Monitoring System

RAM 744In-line CO Monitor

1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800)959-0329•(734)769-0573•www.goodforgas.com

Page 2: RAM 744 - GfG Instrumentationgoodforgas.com/wp-content/uploads/2013/12/RAM_744... · The RAM 744 is the ideal monitor for Respiratory air specifications ... External alarm 90 dB at

Best Safeguard for Quality Breathing AirTheRAM744istheidealmonitorforportableapplicationsandwherespaceislimited.Itismountedwiththefiltrationsystem,allowingforrapidresponseandeliminatingthepossibilityofsamplelinesbecomingblockedorcrimped.Theflowrateisfixedsotherearenotouchyflowmeterstoadjust.

CalibrationandmaintenancearemadesimplewithourinnovativeAutoCal®systemthatallowstheCOsensortobecalibratedwithatestgasconnectionandtheflipofaswitch.Thealarmlevelissetto10ppm.

Thecompact,portable“aircase”enclosesthethree-stage25,50or100CFMfilterpanelwiththeRAM744COmonitorinaruggedcarryingcase*.Allmodelshavequick-connectinletsandoutlets.

AnyGfGInstrumentationRAMinstrumentcanbecustom-configuredtomeettheneedsoftheenduser’sexactspecifications.

Respiratory air specificationsAllGfGInstrumentationRAMinstrumentssatisfytherequirementsofOSHArule29CFR1910.134(d)(2)(ii)forcarbonmonoxidemonitoring.TheywillalsomonitorGradeEair,generallyspecifiedforbreathingairincylinders(SCBA).

OSHA Regulations (Standard - 29 CFR) Respiratory Protection - 1910.134(i)(6)Forcompressorsthatarenotoil-lubricated,theemployer shall ensure that carbon monoxidelevels in the breathing air do not exceed 10ppm.(i)(7)For oil-lubricated compressors, the employershall use a high-temperature or carbonmonoxide alarm, or both, to monitor carbonmonoxide levels. If only high-temperaturealarms are used, the air supply shall bemonitored at intervals sufficient to preventcarbon monoxide in the breathing air fromexceeding10ppm.

7.5"

2.25"

Specifications subject to change without notification

Specifications

Distributedby:

Rev.3(3/18/14)

Tel: (800) 959-0329 or (734) 769-0573 Fax: (734) 769-1888E-mail: [email protected] Website: www.goodforgas.com

Gases

Carbonmonoxide(CO)Detection Range

CO0-99ppm

Detection Principle

COspecificElectrochemicalcell

Display

2digit.5"digitbacklighted*LCD*Externalpowersourcesonly.

Expected Sensor Life

Greaterthan1year

Alarm Point

CO10ppm

Alarms

Audible83dBat1'(30cm)VisualFlashingLEDExternalalarm90dBat1m

Airline Inlet /Outlet

Standardpressure70to150psi1/2"FPT-50to100CFMpanels(wallmount)3/8"-25CFMpanels(wallmount)Dynaquipquickconnects-outlet

Available Relay Contacts and Ratings

N/O,common,N/C0.3Aat125VAC0.1Aat30VDC

Simple Flow Rate

1.0cubicfeetofairperhour(scfh)

Power Source

110VAC(wallpack)12VDCexternal9VDCinternal

Temperature Range

-4to+122ºF/-20to+50ºC

Available Models

8025-744 25CFMwallmountedfilterpanelwithRAM744(2ports)

8050-744 50CFMwallmountedfilterpanelwithRAM744(4ports)

8100-744 100CFMwallmountedfilterpanelwithRAM(8ports)

*9025-744 25CFMportablefilterpanel(2ports)*9050-744 50CFMportablefilterpanel(4ports)*9100-744 100CFMportablefilterpanel(8ports)

*ConsultGfGforcoloroptionsavailableon portablefilterpanels.