rec center renovations - sites.rowan.edu · gfrc glass fiber reinforced concrete ga galv gc ... an...
TRANSCRIPT
DetailDTL
TLT Toilet
Curtain Wall
PLBG Plumbing
VB Vinyl Base
Expansion JointEJ
Glass Fiber Reinforced GypsumGFRG
Unless Otherwise NotedUON
On Center
Opposite
OCOD
PLAM
OPP
Plastic Laminate
Outside Diameter
RadiusRoof drain
PaintedPlywood
PTDPLWD
PT
RRD
RevisionRequired
Room
Reference, Refrigerator
REVREQD
RMRO
REF
Rough opening
Sound Attenuation Blanket
Pressure Treated
Schedule
Similar
SCHED
SIM
SAB
RTU
Structure, Structural
SteelStorage
STRUCTSST
STORSTL
SPECSF
Stainless Steel
SpecificationSquare foot
Roof Top Unit
Typical
Top of
Temporary, Temperature
TOWTYP
TO
TEMP
Water ClosetWith
Vertical
Underwriters Laboratory
WCW/
VWC
VCTVERT
UL
Vinyl Composition Tile
Vinyl Wall covering
Top of wall
WoodWDWO Window Opening
FECFHC
FLRFD
Floor
AFF
A/CACT Acoustical Ceiling Tile
Above Finished Floor
Air Conditioning
GFRC Glass Fiber Reinforced Concrete
GAGALVGC
Gauge
FP Fire Protection
HCHM
GWB
APPROXAPARCH
ALTALUMANOD
BOBLKG
BDBITUM
BlockingBottom Of
BituminousBoard
Anodize
Access PanelArchitect, Architecture
Approximate
AlternateAluminum
INSULINV
InteriorInvert
HORIZ
HVACHTHP
Height
JAN Janitor
INT
CLGCJ
CMU
CAB
CT
COLCONC
CPTCONT Continuous
CarpetCeramic Tile
Concrete Masonry Unit
ConcreteColumn
CeilingControl Joint
Cabinet
MIN
MAXMECH
NIC
MOMTL Metal
MISCMM
DIADIMDN
DWG
DF
EWCEXP
EPSEQ
ELEV
EL
Electric Water CoolerExposed
Elevation
Equal
ElevatorExpanded Polystyrene
Drawing, Drawings
DiameterDimensionDown
Drinking Fountain
NONOMNTS
EXT Exterior
NumberNominal
Not in contract
Not to scale
Masonry Opening
MinimumMiscellaneousMillimeter
MaximumMechanical
Insulation
HorizontalHigh PointHeating, Ventilation, and Air Conditioning
Hollow CoreHollow Metal
Gypsum Wallboard
GalvinizedGeneral contractor
Fire Hose and Valve CabinetFire Extinguisher Cabinet
Floor drain
CW
Opposite HandOHOverheadOHD
FRP Fiberglass Reinforced Plastic
RWC Rainwater conducter
Verify In FieldVIF
Open To StructureOTS
ABBREVIATIONS
CG Corner Guard
C CenterlineL
DownspoutDS
DBL DoubleWP Waterproofing
FT Feet
ELEC Electric, Electrical
TOP Top of Parapet
Sprayed Fire-Resistant MaterialsSFRM
XPS Extruded Polystyrene
Polyvinyl chloridePVC
PNT Paint
Owner Furnished / Owner InstalledOFOI Owner Furnished / Contractor InstalledOFCI
CFCI Contractor Furnished / Contractor Installed
MFR Manufacturer
LAVLP
LavatoryLow Point
FIP Foamed-In-Place
TOILET ACCESSORY TAG
Room name101
150 SF
ROOM TAG: NAME, NUMBER, AREA
A1011
SIM
101 DOOR TAG
DETAIL NUMBER & SHEET REFERENCE(SIM: SIMILAR, OPP: OPPOSITE, MIR: MIRRORED)
CENTERLINE
A101
1 Ref
1
Ref
1 Ref
1
Ref INTERIOR ELEVATION TAG:
DRAWING NUMBER & SHEET REFERENCE
EXTERIOR ELEVATION TAG:DRAWING NUMBER & SHEET REFERENCE
ELEVATION LEVEL REFERENCE
SECTION TAG REFERENCE
A101
1
Ref
1Ref 1 Ref
1
Ref
SPOT ELEVATION REFERENCE
1i
1t
PARTITION TYPE TAG
SHEET DRAWING REFERENCE:NUMBER, NAME, & SCALE
WINDOW TYPE TAG
SYMBOLS LEGEND
KEYNOTE TAG (REFER TO ASSOCIATED SHEET NOTES)
1 View Name1/8" = 1'-0"
NameElevation
1A101
SIM
X
FFE TAG1i
X
BH
A J
ob N
umbe
r:
ISSU
ED F
OR D
CA S
UBMI
SSIO
N 12
/4/17
ISSUE INFORMATION
OWNERROWAN UNIVERSITYphone: 856.256.4948
email: [email protected] PERSON: Anthony Kula
ARCHITECTBlackney Hayes Architects
150 S. Independence Mall West, Suite 1200Philadelphia, PA 19106phone: 215.829.0922
facsimile: 215.829.0596CONTACT PERSON: MEGAN HAYES
ROWAN REVIEW SET 09.01.17
ISSUED FOR BID 11.28.17
ISSUED FOR DCA SUBMISSION 12.4.17
12/4
/201
7 1:
30:2
5 PM
REC CENTER RENOVATIONSROWAN UNIVERSITY- RECREATION CENTER GLASSBORO, NJ
REC
CENT
E RR E
NOVA
TIO N
SR O
WAN
UN I
VERS
ITY -
REC
REAT
ION
C ENT
ER G
LASS
BORO
, NJ
17-0
92
SHEET LIST
SHEET NUMBER SHEET NAME
_CS PROJECT COVER SHEETA0.1 AREA OF WORK PLANSA1.1 SCOPE OF WORK-FLOOR PLANSA2.1 REFLECTED CEILING PLANE1.1 ELEECTRICAL NEW WORK AND DEMOLITIONE1.2 ELECTRICAL SPECIFICATION AND NOTES
REC CENTER LOCATION
PROJECT DESCRIPTION:ALTERATION TYPE 1- INTERIOR CHANGES TO FINISHES IN KIND. NO CHANGES EGRESS OR LIFE SAFETY IS EFFECTED. NO CHANGES TO STRUCTURE, WALLS AND OR DOORS.
UP
dnA1.1
1
A1.12
STORAGE203
STORAGE204
STAIR #2ST2
STAIR 1ST 1
RACQUET BALL COURT#1
207
CORRIDOR215
RACQUET BALL COURT#2
208
ELEV. MACH206
ELEVE1
WEIGHT ROOM202
FITNESS201
A1.13
Sim
REC CENTER MAIN ENTRANCE
LOBBYL100
CONFERENCE113
AEROBICS132
RoomL102
JUICE BAR102
STORAGE131
STORAGE130
STAIRSS2
STAIRSS1
MEN118
WOMEN120
OFFICEMZ101
OFFICE104
OFFICE105
OFFICE106
OFFICE107
STORAGE108
OFFICE110
STORAGE121
WOMEN119
MEN117
STORAGE115
STORAGE114
ELEV1
A1.14
Sim
OFFICE007 SHOWERS
001B
LOCKER ROOM001
LOBBYL001
WOMENS001A
CORRIDORH001
STAIR 1ST1
Warning: Actual conditions may vary from conditions shown on this drawing. Confirm all information in the field before proceeding with any work and notify the Architect in writing if a variation is discovered.
Release
BHA Job Number:
Scale:
Drawn By:
Checked By:
Approved By:
Sheet No.
© Copyright 2015 Blackney Hayes Architects
Seal
Sheet Title:
Project:
Date Comments
Architect:Blackney Hayes Architectsphone: 215.829.0922CONTACT PERSON: Megan Hayes
MEP:
Project Address:
This drawing is not to be copied or transmitted in any form without the express written authorization of Blackney Hayes Architects. All ideas and concepts depicted or suggested in this drawing are the property of Blackney Hayes Architects.
DUTY TO INSPECT CONTRACT DOCUMENTS PRIOR TO STARTING WORK: Any party who relies in part or whole on the content of these Construction Documents shall, before beginning any work, be responsible for fully inspecting the complete set of Contract Documents, including all Drawings, Specifications, and Addenda, for completeness, conflicts, scope of work, and suitability for constructing the building. Contractors and Suppliers must, prior to beginning work, submit all requests for clarifications and additional information to the architect in writing. All parties who begin work hereby certify that the documents are suitable for their intended purposes unless noted in specific written exception.
12/4/17 ISSUED FOR DCA SUBMISSION
Client:Rowan Universityphone: 856.256.4948CONTACT PERSON: Tony Kula
Blackney Hayes Engineeringphone: 215.829.0922CONTACT PERSON: Andrew O'Pella
11/28/17 ISSUED FOR BID9/1/17 ISSUED FOR CLIENT REVEIW
1/16" = 1'-0"
A0.1
AREA OF WORKPLANS
REC CENTERRENOVATIONS
17-092
AuthorCheckerApprover
ROWAN UNIVERSITY-RECREATION CENTERGLASSBORO, NJ
1/16" = 1'-0"1 2nd Floor Overall Plan
1/16" = 1'-0"2 1st Floor Overall Plan
1/16" = 1'-0"3 Basement Overall Plan
1
2
2 2
23
3
3 3
3
3
3
44
4
5 6
TYPICAL THROUGHOUT WEIGHT ROOM
10
11 11 11
11
11
11
N.I.C. N.I.C. N.I.C.
N.I.C.
N.I.C.
N.I.C.
3
17
3
13
131313
17
15
PT-3
7 89
RS-1 RS-1
N.I.C.
PT-3
12
14 14
PT-3
N.I.C.
7 8
BASE
BID
8
9
9
RS-1
RS-1
PT-3
14 14
16
PT-3
N.I.C.
879
RS-1RS-1
PT-3
15
14
ALL MATERIALS TO BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDED INSTRUCTIONS.
PROVIDE REDUCER STRIPS AT CHANGE OF FLOOR MATERIALS AS REQUIRED. COLOR TO MATCH VINYL BASE. REDUCER STRIPS TO BE ADA COMPLIANT.
WHERE ATYPICAL CONDITIONS OCCUR, CONTRACTOR IS TO VERIFY FINISH TREATMENT WITH ARCHITECT BEFORE PROCEEDING.
PAINT ALL DIFFUSERS, GRILLES, ACCESS PANELS ETC. TO MATCH ADJACENT SURFACES.
SUB-FLOOR IS TO BE PATCHED, REPAIRED AND MADE SMOOTH AND LEVEL TO RECEIVE NEW FLOORING.
ALL SOFFITS TO BE SAME FINISH AND COLOR AS ADJACENT WALL U.O.N.
ALL BASE TO BE 4" COVE U.O.N
EXP = EXPOSED
SUBMIT FINISH SAMPLES TO ROWAN UNIVERSITY AND BHA FOR WRITTEN APPROVAL PRIOR TO ORDERING.
PATCH WALL AND REPAIN TO MATCH EXISTING WHERE DAMAGE HAS OCCURED DURING REMOVAL OF WALL BASE, WALL PROTECTION PANELS AND/ OR CORNER GAURDS.
GENERAL NOTES1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
KEY NOTESREMOVE EXISTING FLOORING IN ELEVATOR. PREP FLOOR FOR NEW FLOORING. INSTALL NEW RUBBER FLOORING (RF-1).
REMOVE EXISTING CORNER GUARDS AND WALL PROTECTION PANELS. PREP SURFACE FOR NEW PAINT FINISH AND WALL PROTECTION PANELS. INSTALL NEW WALL PROTECTION PANELS (WP-1) AND CORNER GUARDS (CG-1) TO HEIGHT ALIGNED WITH TOP OF WALL MIRRORS. REMOVE OUTLET FACE PLACES, CUT WALL PROTECTION PANELS AROUND OUTLETS AND RE-INSTALL FACEPLATES ON NEW SURFACE. REMOVE FACILITY RULES AND ADHESIVE. RE-ATTACH IN SAME LOCATION AT END OF JOB.
REMOVE EXISTING WALL PROTECTION PANELS. PATCH AND PREPARE EXISTING WALL FOR NEW WALL PROTECTION PANELS. INSTALL NEW WALL PROTECTION PANELS (WP-1) FROM FLOOR TO UNDERSIDE OF WINDOW FRAME OR MIRROR. HEIGHT OF WALL PROTECTION PANELS SHOULD BE CONTINUOUS AROUND ROOM WHERE IT IS LOCATED BELOW MIRROR OR WINDOWS. REMOVE OUTLET FACE PLACES, CUT WALL PROTECTION PANELS AROUND OUTLETS AND RE-INSTALL FACEPLATES ON NEW SURFACE.
REMOVE EXISTING CORNER GUARDS. PREP SURFACE AND INSTALL NEW CORNER GUARDS (CG-1) FROM, ABOVE WALL BASE TO ALIGN TO TOP OF MIRRORS.
CLEAN, REMOVE CURRENT ROLLED RUBBER AND ADHESIVE AND PREP EXISTING FLOORING TO RECEIVE NEW SPORTS FLOORING OVER EXISTING. INSTALL NEW FLOORING (SF-1). INSTALL PER MANUFACTURERS RECOMMENDATIONS.
REMOVE EXISTING WALL BASE AND PROVIDE NEW THROUGHOUT. (VB-1).
PAINT ALL TRIM, INCLUDING BUT NOT LIMITED TO METAL STAIR STRINGERS, LANDING STRINGERS, UNDERSIDE OF METAL STAIRS, DOOR FRAMES AND STAIR INTERIOR SIDE OF DOORS (PT-4).
PAINT ENTIRE STAIRCASE WALLS (PT-1) U.O.N.
REMOVE EXISTING RUBBER FLOORING ON LANDING, WALL BASE, AND RUBBER STAIR TREADS. PREP FLOOR AS REQUIRED TO RECEIVE NEW FINISH. INSTALL NEW NORA, NORAMENT (RS-1). INSTALL NORA NORAMENT RUBBER SHEET (RF-1) AT STAIR LANDINGS. INSTALL PER MANUFACTURERS RECOMMENDATIONS, FLOOR PREP AND ADHESIVE. INSTALL NEW WALL BASE (VB-1) AT ALL LANDING AND CORRIDOR LOCATIONS THAT DO NOT HAVE METAL STRINGER PERIMETER.
REPAINT STRIPING TO MATCH ADJACENT PAINT BOARDER IN WEIGHT ROOM ABOVE NEW WALL PANELS.
PROVIDE REDUCER STRIP AS SPECIFIED WITH (SF-1) AT DOOR LOCATIONS TO CREATE ADA COMPLIANT TRANSITION. CUT IN FIELD TO ACCOMMODATE DIFFERENT FLOOR PROFILE HEIGHTS. REFER TO DETAIL 5/A1.1
REMOVE EXISTING BULLETIN BOARDS. RETURN TO ROWAN UNIVERSITY.
SAND, PRIME AND PREP ALL DOORS TO RECEIVE NEW PAINT TO MATCH EXISTING.
CLEAN AND REMOVE DEBRIS BETWEEN OVERHEAD STAIR STRINGER AND WALL. PROVIDE CAULK TO FILL GAP PRIOR TO PAINTING.
CONTRACTOR IS RESPONSIBLE FOR RELOCATING ALL FITNESS EQUIPMENT FROM WEIGHT ROOMDURING CONSTRUCTION. AN EXPERIENCED LARGE VOLUME COMMERCIAL FITNESS EQUIPMENT MOVER MUST BE USED FOR THIS JOB ANDAPPROVED BY ROWAN UNIVERSITY PRIOR TO AWARDING JOB. MUST HAVE EXPERIENCE MOVING RACKS, MULTI-JUNGLES AND LARGE PIECES OF FITNESS EQUIPMENT. COORDINATE WITH ROWAN UNIVERSITY FACILITIES FOR REQUIREMENTS OF WHERE FITNESS EQUIPMENT WILL NEED TO BE STORED AND WHICH PIECES REQUIRE DISMANTLING AND REASSEMBLY. G.C.'S FITNESS EQUIPMENT VENDOR IS RESPONSIBLE FOR RELOCATION AND ASSEMBLY OF ALL EQUIPMENT BACK IN WEIGHT ROOM AT PROJECT COMPLETION. REFER TO EQUIPMENT LEGEND FOR ITEMIZED LIST OF EQUIPMENT TO BE RELOCATED.
PAINT STAND PIPE PT-3
PREP SURFACE FOR NEW WALL PROTECTION PANELS. INSTALL NEW WALL PROTECTION PANELS (WP1) TO HEIGHT ALIGNED WITH TOP OF WALL MIRRORS. REMOVE OUTLET FACE PLACES, CUT WALL PROTECTION PANELS AROUND OUTLETS AND RE-INSTALL FACEPLATES ON NEW SURFACE.
1
2
3
4
5
7
8
FINISH LEGENDPAINT:
PT-1 MNF: SHERWIN WILLIAMSCOLOR: MATCH EXISTING GENERAL COLORFINISH: EGGSHELLLOCATION: GENERAL WALLS
PT-2 MNF: SHERWIN WILLIAMSCOLOR: 7545 THUNDER GRAYFINISH: EGGSHELLLOCATION: ACCENT WALLS
PT-3 MNF: SHERWIN WILLIAMSCOLOR: 7607 SANTORINI BLUEFINISH: EGGSHELLLOCATION: ACCENT WALLS
PT-4 MNF: SHERWIN WILLIAMSCOLOR: 7545 THUNDER GRAYFINISH: SEMI-GLOSSLOCATION: TRIM
RUBBER FLOORING:
RF-1 MNF: NORASTYLE: 925 GRANOCOLOR: 4882 BANDED AGATESIZE: 39.45" X 39.45" X .14" THICKLOCATION: STAIR LANDINGS/
CORRIDORS
RUBBER STAIRS:
RS-1 MNF: NORASTYLE: 925- GRANO STAIRTREADS
W/ VISUALLY IMPARED ANTI-SLIP GRIT STRIP (BLACK) ON EVERY TREAD
COLOR: 4882 BANDED AGATESIZE: 6' LONGLOCATION: STAIR TREADS
SPORTS FLOOR:
SF-1 MNF: THOR PERFORMANCE PRODUCTSSTYLE: THOR RESI32 SYSTEM– 32MM ROLLED RUBBERCOLOR: CUSTOM 15% COLOR: 10% LIGHT GRAY, 5% PEARLSIZE: 4’ WIDE ROLLED GOODSCONSTRUCTION: 8MM REGUPOL AKTIV (TOP LAYER) AND THOR THUNDER FLAT UNDERLAYMENT 24MM (BASE LAYER).LOCATION: WEIGHT ROOMNOTE: PROVIDE REGUPOL AKUSTIPRO REDUCER AT ALL DOORS AND TRANSITIONS BETWEEN SPORTS FLOORING AND ADJACENT SURFACES WHERE NEEDED. PLEASE CUT TO HEIGHT IN PLACE, USE RECOMMENDED MNF ADHESIVE. CONTACT: JOE LOPEZ- THOR PERFORMANCE PRODUCTS (917) 485-3200
WALL PROTECTION:
WP-1 MNF: ACROVYNSTYLE: HIGH IMPACT WALL COVERING
RIGID SHEETSCOLOR: GALVENSTON GREYTEXTURE: QUATROSIZE: .075" THICKLOCATION: WEIGHT ROOMNOTE: PROVIDE FINSIHING TRIM PEICE
FOR ALL EXPOSED EDGES
CORNER GAURD:
CG-1 MNF: ACROVYNSTYLE: SM SERIESCOLOR: GALVENSTON GREYSIZE: REFER TO NOTESLOCATION: WEIGHT ROOM
VINYL BASE:
VB-1 MNF: JOHNSONITESTYLE: COVE BASECOLOR: MOON ROCKSIZE: 4"LOCATION: WEIGHT ROOM/ STAIRWELL
6
9
10
11
12
13
14
15
16
17
SPORTS FLOORING
RUBBER REDUCER STRIPCUT TO HEIGHT.SLOPE MUST NOT EXCEED 1:13
EXISTING FLOOR COVERINGS
VARIES
Warning: Actual conditions may vary from conditions shown on this drawing. Confirm all information in the field before proceeding with any work and notify the Architect in writing if a variation is discovered.
Release
BHA Job Number:
Scale:
Drawn By:
Checked By:
Approved By:
Sheet No.
© Copyright 2015 Blackney Hayes Architects
Seal
Sheet Title:
Project:
Date Comments
Architect:Blackney Hayes Architectsphone: 215.829.0922CONTACT PERSON: Megan Hayes
MEP:
Project Address:
This drawing is not to be copied or transmitted in any form without the express written authorization of Blackney Hayes Architects. All ideas and concepts depicted or suggested in this drawing are the property of Blackney Hayes Architects.
DUTY TO INSPECT CONTRACT DOCUMENTS PRIOR TO STARTING WORK: Any party who relies in part or whole on the content of these Construction Documents shall, before beginning any work, be responsible for fully inspecting the complete set of Contract Documents, including all Drawings, Specifications, and Addenda, for completeness, conflicts, scope of work, and suitability for constructing the building. Contractors and Suppliers must, prior to beginning work, submit all requests for clarifications and additional information to the architect in writing. All parties who begin work hereby certify that the documents are suitable for their intended purposes unless noted in specific written exception.
12/4/17 ISSUED FOR DCA SUBMISSION
Client:Rowan Universityphone: 856.256.4948CONTACT PERSON: Tony Kula
Blackney Hayes Engineeringphone: 215.829.0922CONTACT PERSON: Andrew O'Pella
11/28/17 ISSUED FOR BID9/1/17 ISSUED FOR CLIENT REVEIW
As indicated
A1.1
SCOPE OFWORK-FLOORPLANS
REC CENTERRENOVATIONS
17-092
MCHMLBKB/JH
ROWAN UNIVERSITY-RECREATION CENTERGLASSBORO, NJ
1/4" = 1'-0"1 2nd Fl Weight Room- BASE BID
1/4" = 1'-0"2 2nd Floor Stairs 1/4" = 1'-0"3 1st Floor Stairs 1/4" = 1'-0"4 Basement Stairs
6" = 1'-0"5 FLOOR TRANSISTION DETAIL
1
"A"
"B" "B"
"B"
3
2
2
"B"
KEY NOTES
REMOVE EXISTING CEILING TILES AND GRID. INSTALL NEW CEILING (ACT-1) AT SAME HEIGHT AND LAYOUT AS EXISTING CEILING. REMOVE EXISTING LIGHT FIXTURES, INSTALL NEW2X4 LED (TYPE C) FIXTURES IN SAME LOCATION AS EXISITNG WERE REMOVED, TIE NEW LIGHTS INTO CIRCUIT AND SWITCH OF EXISTING LIGHTS THAT WERE REMOVED. SALVAGE ANY DEVICES FOR RE-INSTALLATION AT SAME LOCATION. NOT LIMITED TO MECHANICAL GRILLS/ REGISTERS, FIRE ALARM AND PROTECTION, EXIT SIGNS, OCCUPANCY SENSORS AND SPEAKERS. INSTALL NEW CEILING GRID IN SAME LOCATION AS PREVIOUSLY EXISTING CEILING. RE-INSTALL ALL DEVICES, LIGHT FIXTURES, GRILLS AND DIFFUSERS, ELECTRICAL AND LIFE SAFETY IN SAME LOCATION AS EXISTING. REFER TO LIGHTING LEGEND FOR WEIGHT ROOM RECESSED LIGHT FIXTURE SPEC. REFER TO ELECTRICAL DRAWINGS.
REMOVE EXISTING WALL SCONCES FROM WALL. PATCH CMU AND PREP FOR NEW PAINT.
INSTALL NEW DOWN LIGHTS IN EXISTING CEILING (TYPE A AND B) REPLACE DAMAGED CEILING TILES TO MATCH EXISTING AS REQUIRED. SWITCH NEW LIGHT FIXTURES TOGETHER TO TIE INTO EXISTING STAIRWELL LIGHT FIXTURES. REFER TO ELECTRICAL DRAWINGS.
1
2
3
A
LED HIGH HAT 6"FOCAL POINTFL6H-RO-5000l-25k-WFL-XX-L11-T L6H-RD-DN-WP
LED HIGH HAT 6"FOCAL POINTFLC6D-3000l-120-L11-T-EM-LC6EM-RC-300-L-35K-DN-WH-WPUSE EMERGENCY FIXTURES AS REQUIRED ON ELECTRICAL DRAWINGS
B
LIGHTING LEGEND
TYPE C:LED DIRECT/INDIRECT 2X4 RECESSED FIXTUREFOCAL POINTAMICA 2X4FAML-24-ACR-4000L-35K-XXX-LD1-XXX-WH
COORIDNATE MOUNTING TYPE WITH GRID. USE EMERGENCY FIXTURES AS REQUIRED ON ELECTRICAL DRAWINGS.
WEIGHT ROOM RECESSED LIGHTING SPEC
EXISTING SUPPLY REGISTER TO BE TEMPORARILY REMOVED, CLEANED AND RELOCATED
EXISTING RETURN REGISTER TO BE TEMPORARILY REMOVED, CLEANED AND RELOCATED
EXISTING SPRINKLER HEAD. REMOVE ESCUTCHEON CAPS AND REPLACE WITH NEW
EXISTING EXIT SIGN. REMOVE FOR CONSTRUCTION AND RE-INSTALL.
(ACT-1)ARMSTRONG ULTIMA WHITE, 2X4 TEGULAR BEVELED (CONFIRM CEILING PROFILE MATCHES EXISTING TILE PRIOR TO ORDERING FOR COORDINATION WITH HEIGHTS OF EXISTING SPRINKLER HEADS) SUPERFINE XL 9/16"
Warning: Actual conditions may vary from conditions shown on this drawing. Confirm all information in the field before proceeding with any work and notify the Architect in writing if a variation is discovered.
Release
BHA Job Number:
Scale:
Drawn By:
Checked By:
Approved By:
Sheet No.
© Copyright 2015 Blackney Hayes Architects
Seal
Sheet Title:
Project:
Date Comments
Architect:Blackney Hayes Architectsphone: 215.829.0922CONTACT PERSON: Megan Hayes
MEP:
Project Address:
This drawing is not to be copied or transmitted in any form without the express written authorization of Blackney Hayes Architects. All ideas and concepts depicted or suggested in this drawing are the property of Blackney Hayes Architects.
DUTY TO INSPECT CONTRACT DOCUMENTS PRIOR TO STARTING WORK: Any party who relies in part or whole on the content of these Construction Documents shall, before beginning any work, be responsible for fully inspecting the complete set of Contract Documents, including all Drawings, Specifications, and Addenda, for completeness, conflicts, scope of work, and suitability for constructing the building. Contractors and Suppliers must, prior to beginning work, submit all requests for clarifications and additional information to the architect in writing. All parties who begin work hereby certify that the documents are suitable for their intended purposes unless noted in specific written exception.
12/4/17 ISSUED FOR DCA SUBMISSION
Client:Rowan Universityphone: 856.256.4948CONTACT PERSON: Tony Kula
Blackney Hayes Engineeringphone: 215.829.0922CONTACT PERSON: Andrew O'Pella
11/28/17 ISSUED FOR BID9/1/17 ISSUED FOR CLIENT REVEIW
As indicated
A2.1
REFLECTEDCEILING PLAN
REC CENTERRENOVATIONS
17-092
AuthorCheckerApprover
ROWAN UNIVERSITY-RECREATION CENTERGLASSBORO, NJ 1/4" = 1'-0"1 WEIGHT ROOM- REFLECTED CEILING PLAN
1/4" = 1'-0"2 2nd Floor Stairs