reconstructive medical & surgical tm · ordering information 55-02950 smartlock hybrid mmf...
TRANSCRIPT
Reconstructive
Hips
Knees
Trauma & Extremities
Joint Preservation
Orthobiologics
Medical & Surgical
Power Tools & Surgical Accessories
Image Guided Navigation
Endoscopy & Arthroscopy
Integrated Communications
Beds, Stretchers & EMS
Sustainability Solutions
Neurotechnology & Spine
Craniomaxillofacial
Interventional Spine
Neurosurgical, Spine & ENT
Neurovascular
Spinal Implants
A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always refer to the packageinsert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area.
Stryker Corporation or its divisions or other corporate affi liated entities own, use or have applied for the following trademarks or service marks: Colorado, Leibinger, MEDPOR, SMARTLock, Stryker. All other trademarks are trademarks of their respective owners or holders.
Literature Number 9410-400-374-SSP Rev. None
Copyright © 2012 StrykerPrinted in Australia
Stryker Australia8 Herbert StreetSt LeonardsNSW 2065 AustraliaPh: + 61 2 9467 1000Fax: + 61 2 9467 1010
Stryker New Zealand515 Mt Wellington HighwayAuckland 1060 New ZealandPh: + 64 9 573 1890Fax: + 64 9 573 1891
www.stryker.com
TM
Introducing SMARTLock Hybrid MMFA revolutionary, patented product designed to combine thestrength and rigidity of arch bars with the safety and effi ciencyof MMF screws. With nine potential points of fi xation along the plate, posterior fi xation and vector control are enhanced when compared to traditional MMF screws. The self-drilling, locking technology of the screws allows for purchase into boththe bone and the plate for additional stability. This plate and screw combination omits the need for interdental wiring that is required with arch bars, and thereby reduces the chance of wire stick injuries for health care providers.
You will only fi nd this unique design from Stryker Craniomaxillofacial.
US Pat. 8,118,850
For over half a century, Stryker has been developing products based on the expressed needs of leading practitioners.
A Legacy of Serving theSurgical Community
FEATURE BENEFIT POTENTIAL VALUE
Reinvented versatile arch bar plate design Eliminates interdental wiring Improves OR effi ciency Reduces risk of wire stick injuries Eliminates risk of tooth loosening Eliminates need for OR based removal
Optimized self-drilling screw with patented SMARTLock technology
Minimizes risk of screw backout Rigid plate-to-screw construct
Strong, stable anterior and posterior fi xation
Dedicated instrumentation Ability to fi xate with patient specifi c anatomical structures in mind
Reduces risk of tooth root injuries Reduces risk of pressure necrosis
Step By Step Instructions
Adjust the length of the locking plate with the cutter.
2
Contour the plate.
Insert locking screw into the center of the plate hole while positioning the spacer instrument between the mucosa and the metal rim of the plate hole. The bar of the middle plate hole is marked to provide midline orientation.
Insert locking screw into the center of the plate hole while positioning the spacer instrument between the mucosa and the metal rim of the plate hole. The bar of the middle plate hole is marked to provide midline
Contour the plate.
3
1
US Pat. 6,322,562
Introducing SMARTLock Hybrid MMFA revolutionary, patented product designed to combine thestrength and rigidity of arch bars with the safety and effi ciencyof MMF screws. With nine potential points of fi xation along the plate, posterior fi xation and vector control are enhanced when compared to traditional MMF screws. The self-drilling, locking technology of the screws allows for purchase into boththe bone and the plate for additional stability. This plate and screw combination omits the need for interdental wiring that is required with arch bars, and thereby reduces the chance of wire stick injuries for health care providers.
You will only fi nd this unique design from Stryker Craniomaxillofacial.
US Pat. 8,118,850
For over half a century, Stryker has been developing products based on the expressed needs of leading practitioners.
A Legacy of Serving theSurgical Community
FEATURE BENEFIT POTENTIAL VALUE
Reinvented versatile arch bar plate design Eliminates interdental wiring Improves OR effi ciency Reduces risk of wire stick injuries Eliminates risk of tooth loosening Eliminates need for OR based removal
Optimized self-drilling screw with patented SMARTLock technology
Minimizes risk of screw backout Rigid plate-to-screw construct
Strong, stable anterior and posterior fi xation
Dedicated instrumentation Ability to fi xate with patient specifi c anatomical structures in mind
Reduces risk of tooth root injuries Reduces risk of pressure necrosis
Step By Step Instructions
Adjust the length of the locking plate with the cutter.
2
Contour the plate.
Insert locking screw into the center of the plate hole while positioning the spacer instrument between the mucosa and the metal rim of the plate hole. The bar of the middle plate hole is marked to provide midline orientation.
Insert locking screw into the center of the plate hole while positioning the spacer instrument between the mucosa and the metal rim of the plate hole. The bar of the middle plate hole is marked to provide midline
Contour the plate.
3
1
US Pat. 6,322,562
4
6
Use the hooks of the locking plates as anchor points to apply the wires between the mandible and maxilla.
Insert a locking screw into at least every other plate hole while using the spacer instrument to avoid compression on the gingiva.
Verify that all plate holes are directed away from or placed in-between the tooth roots. Use the bender instrument for in-situ adjustments of the plate holes, if needed.
5
Complementary Products
Universal II SystemThe Leibinger Universal CMF Trauma System represents the next generation of bone fi xation for all Craniomaxillofacial fractures, orthognathic, and reconstructive needs.
CMF Customized ImplantsCMF Customized Implants (CI) are designed specifi cally for each patient to correct trauma and/or defects in maxillofacial or craniofacial bone. Stryker CI technology offers excellent anatomical fi t and contour allowing surgeons to create exceptional cosmetic results.
MEDPOR Reconstructive ImplantsMEDPOR Porous Polyethylene Implants provide surgeons with an expanding range of options for reconstruction and augmentation. MEDPOR is a biocompatible, porous polyethylene material. The interconnecting, omni-directional pore structure may allow for fi brovascular in-growth and integration of the patient’s tissue. More than 400,000 procedures have been performed with MEDPOR Biomaterial, with more than 350 published clinical reports in cranial, reconstructive, oculoplastic and cosmetic applications.
Applications• Implant modules for specifi c anatomical areas• Fully customizable for clinician and hospital needs• Color coordinated "universal" instrumentation & implants• SMARTLock locking technology
Applications• PEEK Customized Cranial Implant Kit is intended to replace bony voids in the cranial and craniofacial skeleton.
Applications• Craniofacial reconstruction and repair of the craniofacial skeleton• Implants with titanium mesh embedded in the MEDPOR Biomaterial are designed to help the implant retain its shape when bent and contoured to meet a specifi c patient defect• May be trimmed and cut with surgical scissors.• Easily fi xated with plates/screws and designed to stay in place
PEEK
Colorado NeedleThe Colorado Microdissection Needle has an ultra-sharp tip for clean, precise soft tissue dissection. The heat resistant tungsten alloy maintains tip sharpness, and is highly polished for easy cleaning. We offer a wide selection of needle electrodes and standard shaft sizes for use in standard handpieces.
Applications• Precise electro-cutting and coagulation during electrosurgery
Ordering Information
55-02950 SmartLock Hybrid MMF Plate
62-18330 In-situ Plate Cutter
62-20290 Screwdriver Handle, Ratcheting
62-20135 MMF Screwdriver Blade and Grasping Sleeve, Assembled
62-20130 2.0/2.3 Screwdriver Blade for Self-Drilling Locking Screws
60-16526 Twist Drill 1.6x58mm, 20mm WL, Stryker End
01-03490 Ligature Wires, Blunt, 0.5x160mm, 24 gauge
01-03492 Ligature Wires, Blunt, 0.64x160mm, 22 gauge
50-20358 MMF Screws, SD, 2.0x8mm50-20362 MMF Screws, SD, 2.0x12mm
50-20596 Locking Screws, SD, 2.0x6mm
50-20598 Locking Screws, SD, 2.0x8mm
PART NO. DESCRIPTION PART NO. DESCRIPTION
62-00604 SmartLock Hybrid MMF Bender
29-20426 SmartLock Hybrid MMF Container Lid, Quarter Size
29-15031 Universal Container, Quarter Size, Two-layer
29-15036 Accessory Tray, Quarter Size
29-15037 Silicone Mat For Accessory Tray, Quarter Size
29-20420 SmartLock Hybrid MMF Module with Lid
29-20421 SmartLock Hybrid MMF Inlay
62-00605 SmartLock Hybrid MMF Spacer
36-06720 Automatic Wire Twister 15cm
OPTIONAL
Ordering Information
55-02950 SmartLock Hybrid MMF Plate
62-18330 In-situ Plate Cutter
62-20290 Screwdriver Handle, Ratcheting
62-20135 MMF Screwdriver Blade and Grasping Sleeve, Assembled
62-20130 2.0/2.3 Screwdriver Blade for Self-Drilling Locking Screws
60-16526 Twist Drill 1.6x58mm, 20mm WL, Stryker End
01-03490 Ligature Wires, Blunt, 0.5x160mm, 24 gauge
01-03492 Ligature Wires, Blunt, 0.64x160mm, 22 gauge
50-20358 MMF Screws, SD, 2.0x8mm50-20362 MMF Screws, SD, 2.0x12mm
50-20596 Locking Screws, SD, 2.0x6mm
50-20598 Locking Screws, SD, 2.0x8mm
PART NO. DESCRIPTION PART NO. DESCRIPTION
62-00604 SmartLock Hybrid MMF Bender
29-20426 SmartLock Hybrid MMF Container Lid, Quarter Size
29-15031 Universal Container, Quarter Size, Two-layer
29-15036 Accessory Tray, Quarter Size
29-15037 Silicone Mat For Accessory Tray, Quarter Size
29-20420 SmartLock Hybrid MMF Module with Lid
29-20421 SmartLock Hybrid MMF Inlay
62-00605 SmartLock Hybrid MMF Spacer
36-06720 Automatic Wire Twister 15cm
OPTIONAL
4
6
Use the hooks of the locking plates as anchor points to apply the wires between the mandible and maxilla.
Insert a locking screw into at least every other plate hole while using the spacer instrument to avoid compression on the gingiva.
Verify that all plate holes are directed away from or placed in-between the tooth roots. Use the bender instrument for in-situ adjustments of the plate holes, if needed.
5
Complementary Products
Universal II SystemThe Leibinger Universal CMF Trauma System represents the next generation of bone fi xation for all Craniomaxillofacial fractures, orthognathic, and reconstructive needs.
CMF Customized ImplantsCMF Customized Implants (CI) are designed specifi cally for each patient to correct trauma and/or defects in maxillofacial or craniofacial bone. Stryker CI technology offers excellent anatomical fi t and contour allowing surgeons to create exceptional cosmetic results.
MEDPOR Reconstructive ImplantsMEDPOR Porous Polyethylene Implants provide surgeons with an expanding range of options for reconstruction and augmentation. MEDPOR is a biocompatible, porous polyethylene material. The interconnecting, omni-directional pore structure may allow for fi brovascular in-growth and integration of the patient’s tissue. More than 400,000 procedures have been performed with MEDPOR Biomaterial, with more than 350 published clinical reports in cranial, reconstructive, oculoplastic and cosmetic applications.
Applications• Implant modules for specifi c anatomical areas• Fully customizable for clinician and hospital needs• Color coordinated "universal" instrumentation & implants• SMARTLock locking technology
Applications• PEEK Customized Cranial Implant Kit is intended to replace bony voids in the cranial and craniofacial skeleton.
Applications• Craniofacial reconstruction and repair of the craniofacial skeleton• Implants with titanium mesh embedded in the MEDPOR Biomaterial are designed to help the implant retain its shape when bent and contoured to meet a specifi c patient defect• May be trimmed and cut with surgical scissors.• Easily fi xated with plates/screws and designed to stay in place
PEEK
Colorado NeedleThe Colorado Microdissection Needle has an ultra-sharp tip for clean, precise soft tissue dissection. The heat resistant tungsten alloy maintains tip sharpness, and is highly polished for easy cleaning. We offer a wide selection of needle electrodes and standard shaft sizes for use in standard handpieces.
Applications• Precise electro-cutting and coagulation during electrosurgery
Reconstructive
Hips
Knees
Trauma & Extremities
Joint Preservation
Orthobiologics
Medical & Surgical
Power Tools & Surgical Accessories
Image Guided Navigation
Endoscopy & Arthroscopy
Integrated Communications
Beds, Stretchers & EMS
Sustainability Solutions
Neurotechnology & Spine
Craniomaxillofacial
Interventional Spine
Neurosurgical, Spine & ENT
Neurovascular
Spinal Implants
A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always refer to the packageinsert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area.
Stryker Corporation or its divisions or other corporate affi liated entities own, use or have applied for the following trademarks or service marks: Colorado, Leibinger, MEDPOR, SMARTLock, Stryker. All other trademarks are trademarks of their respective owners or holders.
Literature Number 9410-400-374-SSP Rev. None
Copyright © 2012 StrykerPrinted in Australia
Stryker Australia8 Herbert StreetSt LeonardsNSW 2065 AustraliaPh: + 61 2 9467 1000Fax: + 61 2 9467 1010
Stryker New Zealand515 Mt Wellington HighwayAuckland 1060 New ZealandPh: + 64 9 573 1890Fax: + 64 9 573 1891
www.stryker.com
TM