sKE 0.81 * * * 76
KT 2.47 * * * 76
RS 3.36 * * * 78
RSI 3.35 * * * * 78
KDRE 3.07 * * 82
KDRD 4.13 * * 82
MUB 5.5 * * * * 84
KVD 1.99 * * * * 88
KVB 2.5 * * * 88
KPB 5.41 * * * 91
KPD DUO 1.94 * * * * * 100
KPB DUO 5.4 * * * * 100
Accessories
76
K-Fan
Rectangular & Square Duct Fans
KE / KT - Rectangular Duct Fans
The KE/ KT models have impellers with forward-curved blades and external rotor motors. The motor and impeller are mounted on the access cover to facilitate easy maintenance. The casing is manufactured from galvanised sheet steel. To protect the motor from overheating the fans have integral thermal contacts with external leads for connection to a motor protection device. The fans can be installed in any position and are easy to connect using the DS flexible connections. The KE/KT fans have a pre-wired, integral terminal box. KE is single phase, KT is three phase.
Product
Code
SFP*
(kW/m3/sec)
Voltage Speed
rpmAirflow m3/sec @ Static Pressure Pa. Motor Data dBA @
3m
Speed Control
100 150 200 250 300 400 FLC SC kW
KE40-20-4 0.95 230 1206 0.266 0.241 0.20 0.008 - - 1.0 4.0 0.227 55 RTRE 1.5
KE50-25-4 1.15 230 1298 0.42 0.38 0.34 0.27 - - 2.51 8.0 0.533 55 RTRE 3
KE50-30-4 1.43 230 1193 0.59 0.55 0.52 0.46 0.4 - 3.67 12.4 0.819 59 RTRE 5
KE60-30-4 1.68 230 1342 0.74 0.72 0.66 0.63 0.58 0.40 5.4 18.0 1.231 62 RTRE 7
KT50-25-4 0.95 400 1287 0.48 0.44 0.40 0.33 0.23 - 0.95 3.9 0.55 58 RTRD 2
KT50-30-4 1.21 400 1193 - 0.61 0.57 0.50 0.41 0.10 1.41 4.5 0.80 57 RTRD 2
KT60-30-4 1.2 400 1342 0.88 0.85 0.82 0.76 0.71 0.53 2.36 6.7 1.36 58 RTRD 4
KT60-35-4 1.68 400 1250 - - 1.27 1.22 1.18 1.05 4.12 21.0 2.46 61 RTRD 7
KT70-40-4 1.92 400 1297 - - - - 1.63 1.52 6.04 26.5 3.616 66 RTRD 7
KT70-40-6 0.93 400 805 1.31 1.23 1.15 1.06 0.91 - 3.0 18.2 1.628 57 RTRD 4
KT80-50-6 1.1 400 842 2.03 1.98 1.88 1.75 1.61 1.25 4.91 23.2 2.67 59 RTRD 7
KT80-50-8 0.7 400 552 1.32 1.17 1.0 0.69 - - 2.4 13.7 1.14 59 RTRD 4
KT100-50-6 1.44 400 837 - 2.6 2.5 2.4 2.35 2.2 6.79 27.2 3.81 62 RTRD 7
KT100-50-8 0.89 400 614 2.05 1.91 1.78 1.6 1.32 - 4.67 22.8 2.29 58 RTRD7
KE 40-20-4KE 50-25-4KE 50-30-4KE 60-30-4
1
2
3
4
1 2 3 4
KT 50-25-4
KT 50-30-4KT 60-30-4KT 60-35-4KT 70-40-4
1
23
45
1 2 3
4
5
* measured @ maximum efficiency point
• Swing-out Motor & Impeller for access• Speed-controllable• Integral thermal contacts• Can be installed in any position• Maintenance-free and reliable• KE - 1phase KT - 3phase
RetailSchoolsIndustry
RBPage 201
VBRPage 203
DSPage 220
SRKPage 222
PGKPage 204
DXREPage 205
FFSPage 211
3
KE40-20-4KE50-25-4KE50-30-4KE60-30-4
Accessories
77
Rectangular & Square Duct Fans
K-FanKE / KT Fan Dimensions
Product
Code
A c/c B C D E c/c F G H J Weight
Kg
KE40-20-4 240 220 198 502 398 420 440 28 530 12
KE50-25-4 290 270 248 532 498 520 540 30 610 18
KE50-25-4 340 320 298 562 498 520 540 32 695 23
KE60-30-4 340 320 298 642 598 620 640 34 715 34
KT50-25-4 290 270 248 532 498 520 540 64 610 18
KT50-30-4 340 320 298 562 498 520 540 66 695 21
KT60-30-4 340 320 298 642 598 620 640 70 715 31
KT60-35-4 390 370 348 717 598 620 640 95 805 37
KT70-40-4 440 420 398 787 698 720 740 116 900 56
KT70-40-6 440 420 398 787 698 720 740 94 900 42
KT80-50-6 540 520 497 880 798 820 840 97 1080 64
KT80-50-8 540 520 497 880 798 820 840 97 1080 56
KT100-50-6 540 520 497 980 998 1020 1040 97 1130 80
KT100-50-8 540 520 497 980 998 1020 1040 97 1130 80
KE / KT Fan Sound Data
KE40-20-4
KE50-25-4
KE50-25-4
KE60-30-4
KT50-25-4
KT50-30-4
KT60-30-4
KT60-35-4
KT70-40-4
KT70-40-6
KT80-50-6
KT80-50-8
KT100-50-6
KT100-50-8
WIRINGPage 256
RE 1.5Page 229
VKPage 214
LDRPage 207
STL Page 229
RTRDPage 230
EFDPage 222
PRSPage 218
3
Accessories
78
K-Fan
Rectangular & Square Duct Fans
RS / RSI - Centrifugal Duct Fan
1
2
3
4
1 2 3 4 12
34
1
2
3
4
1
2
3
4
12 3 4
Product
Code
SFP**
(kW/m3/sec)
Voltage Speed
rpmAirflow m3/sec @ Static Pressure Pa. Motor Data dBA @ 3m Speed Control
100 150 200 250 300 400 FLC kW RS RSI Elec Trans
RS 30-15 0.87 240 2431 0.106 0.088 0.072 0.06 0.033 - 0.26 0.060 48 - STL 1.5 RE 1.5
RS 40-20M 0.97 240 2597 0.180 0.165 0.142 0.113 0.094 0.04 0.46 0.106 52 - STL 1.5 RE 1.5
RS 40-20L 1.11 240 2556 0.300 0.271 0.26 0.24 0.21 0.17 0.93 0.208 53 - STL 1.5 RE 1.5
RS 50-25 0.66 240 1362 0.312 0.264 0.210 0.14 0.025 - 0.6 0.138 46 - STL 1.5 RE 1.5
*RS 60-35M1 0.69 240 1365 0.80 0.74 0.640 0.61 0.50 0.25 1.91 0.401 58 50 STL 3.0 RE 3.0
*RS 60-35M3 0.77 400 1371 0.850 0.790 0.700 0.63 0.520 0.22 0.80 0.399 58 48 - RTRD 2
*RS 60-35L1 1.08 240 1308 1.000 0.900 0.820 0.69 0.650 0.45 2.80 0.626 58 52 STL 5.0 RTRE 3
*RS 60-35L3 1.03 400 1408 1.050 1.000 0.920 0.85 0.770 0.58 1.59 0.665 61 57 - RTRD 2
*RS 70-40L1 0.69 240 1308 1.400 1.300 1.200 1.08 0.980 0.65 2.84 0.623 60 51 STL 5.0 RTRE 3
*RS 70-40L3 0.95 400 1410 1.260 1.190 1.100 1.03 0.930 0.70 1.7 0.704 61 50 - RTRD 2
*RS 80-50M3 1.14 400 1335 1.790 1.680 1.600 1.49 1.400 1.15 1.97 1.089 60 53 - RTRD 4
*RS 80-50L3 1.4 400 1385 2.375 2.290 2.220 2.09 2.000 1.75 3.6 1.893 63 56 - RTRD 7
*RS 100-50L3 1.81 400 1361 3.180 3.050 2.960 2.80 2.750 2.52 5.09 2.962 65 62 - RTRD 7
* Model available as RSI acoustic fan.
The RS & RSI models have impellers with backward-curved blades and external rotor motors. The motor and impeller are mounted on the access cover to facilitate easy maintenance. To protect the motor from overheating the RS & RSI has integral thermal contacts with external leads for connection to a motor protection device. The fan can be installed in any position and is easy to connect using the DS flexible connections. The casing is manufactured from galvanised sheet steel. The RSI models are thermally and acoustically insulated with 50 mm of mineral wool, with perforated sheet steel on the inner surface.* Model available as RSI acoustic fan.
** measured @ maximum efficiency point
• Speed-controllable• Integral thermal contacts• Can be installed in any position• Maintenance-free and reliable• RSI Model with Acoustic InsulationRetailSchoolsIndustry
RBPage 201
VBRPage 203
DSPage 220
SRKPage 222
PGKPage 204
DXREPage 205
FFSPage 211
3
Accessories
79
Rectangular & Square Duct Fans
K-FanRS / RSI Fan Sound Data
RSI 60-35M1RSI 60-35M3RSI 60-35L1RSI 60-35L3
1 2
4
3
1 2 3 4
RSI 70-40L1RSI 70-40L3RSI 80-50M3RSI 80-50L3RSI 100-50L3
123
4
5
12 3 4 5
RS 30-15
RS 40-20M
RS 40-20L
RS 60-35L3
RS 70-40L
RS 70-40L3
RS 50-25
RS 80-50M3
RS 60-35M1
RS 80-50L3
RS 60-35M3
RS 100-50L3
RS 60-35L1
WIRINGPage 256
RE 1.5Page 229
VKPage 214
LDRPage 207
STL Page 229
RTRDPage 230
EFDPage 222
PRSPage 218
3
RSI Breakout
Sound power (Lw) dB(A)
Mid frequency band LwA Surrounding
63 125 250 500 1k 2k 4k 8k Tot
RSI 60-35M1 29 47 54 47 47 44 38 29 57
RSI 60-35M3 29 47 50 48 47 45 37 35 55
RSI 60-35L1 40 54 54 52 49 47 43 39 59
RSI 60-35L3 26 56 59 57 52 54 55 48 64
RSI 70-40L3 39 46 51 52 50 48 44 39 57
RSI 80-50M3 40 51 53 53 52 49 49 50 60
RSI 80-50L3 43 56 55 59 54 52 46 46 63
RSI 100-50L3 53 62 61 61 63 61 56 54 69
Breakout surrounding Data for RSI models
80
K-Fan
Rectangular & Square Duct Fans
K-FanRS / RSI Fan Dimensions
B Dc/
c F
H
Gc/c E
C
ø10,0 (x8)
A
KI
JL
8,0
RSI A B C D E F G H I J K L M N O kg
60-35M/L 708 492 640.5 391 620 370 598 347.5 55 92.5 640 139.5 99.5 532 597 61
70-40L1/L3 808 542 741 441 720 420 697 397 55.5 92.5 787 201 169.5 532 597 80
80-50M3/L3 908 662 841 541 820 520 797 497 55.5 112.5 882 194 144.5 656 717 107
100-50L3 1108 662 1041 541 1020 520 997 497 55.5 112.5 982 310 244.5 656 717 137
ø10,0 (x8)
Gc/c E
CA
I
Hc/
c F
D B
J
L NM
O
K
~1200
RS A B C D E F G H I J K L kg
30-15 402 217 340 190 320 170 298 148 79 120 230 254 7
40-20 502 267 440 240 420 220 398 198 99 125 311 353 12
50-25 532 317 540 290 520 270 498 248 125 85.5 366 423 17
60-35 717 402 640 390 620 370 598 348 128 145 490 524 35
70-40 787 452 740 440 720 420 698 398 190 215 490 524 43
80-50 882 573 840 541 820 520 798 498 183 190 614 644 68
100-50 982 583 1040 541 1020 520 998 498 299 290 614 644 97
PGK
RB
VBR
SRK
FFK
DS
KE /KT
RS
LDRDS
TYPICAL ACCESSORIES AVAILABLE
RSI
3
81
Rectangular & Square Duct Fans
K-FanAccessories
Examples of using the bolt-on accessories to make off the shelf Air Handling Units
Supply AHU with LPHW HeatingKDRD - Square Mixed flow fan FFS - Bag FilterVBK - LPHW Heating batteryAir Volumes up to 2.8m3/s
Supply AHU with Elec HeatingKDRE - Square Mixed flow fan FFS - Bag FilterRBK - Electric Heating batteryAir Volumes up to 2.5m3/s
3
Accessories
82
K-Fan
Rectangular & Square Duct Fans
KDRE / KDRD - Square Mixed Flow Fans
Product
Code
SFP*
(kW/m3/s)
Speed
rpm
Airflow m3/sec @ Static Pressure Pa. Motor Data dBA @
3m
Speed Control
50 100 200 300 400 FLC SC kW Elec Trans
KDRE45 0.54 1387 0.882 0.740 0.185 - - 1.55 5.0 0.325 46 STL3.0 RTRE3
KDRE50 0.63 1297 1.310 1.149 0.680 0.120 - 1.94 7.5 0.442 52 STL5.0 RTRE5
KDRE55 0.8 1280 1.810 1.657 1.240 0.666 0.130 4.10 11.0 0.861 51 STL5.0 RTRE5
KDRE65 0.92 1315 2.900 2.710 2.230 1.580 0.885 6.61 16.0 1.501 61 STL10.0 RTRE7
KDRD50 0.63 1397 1.380 1.260 0.890 0.260 0.96 6.0 0.462 54 RTRD2
KDRD55 0.77 1315 1.746 1.610 1.280 0.760 0.140 1.52 7.5 0.789 55 RTRD2
KDRD65 0.91 1341 2.743 2.577 2.140 1.480 0.740 2.23 10.0 1.250 53 RTRD4
KDRD70 1.04 1400 3.960 3.800 3.400 2.930 2.320 4.68 25.0 2.493 62 RTRD7
KDRE/KDRD fans have an external rotor motor with a mixed flow type impeller. The KDRE/KDRD series is notable for its relatively high static pressure and high level of efficiency. The casing is manufactured from galvanised sheet steel. To protect the motor from overheating, the KDRE/KDRD fans have integral thermal contacts with leads for connection to a motor protection device. The fans can be installed in any position and are easy to connect using the DSK flexible connections.
1234
1 2 3 4
1
234
1 2 3 4
* measured @ maximum efficiency point
• KDRE Fan - single phase. 230V - 1Ph - 50Hz• KDRD Fan - three phase. 400V - 3Ph - 50Hz• Speed-controllable• Integral thermal contacts• Can be installed in any positions• Maintenance-free and reliable
Industry Retail Schools
SRKGPage 222
DSKPage 220
RBKPage 202
LDKPage 206
FFKPage 213
VBKPage 202
3
Accessories
83
Rectangular & Square Duct Fans
K-FanKDRE / KDRD Fan Dimensions
KDRE/KDRD A B C D kg
KDRE 45 447 470 492 400 26
KDRE/KDRD 50 502 520 547 450 41
KDRE/KDRD 55 550 573 595 485 42
KDRE/KDRD 65 661 680 707 510 54
KDRD 70 696 720 740 530 62
ø10(4x)
45
A *c/cB
C
KDRE / KDRD Fan Sound Data
KDRE 50
KDRE 45
KDRE 55
KDRE 65
KDRD 50
KDRD 55
KDRD 65
KDRD 70
WIRINGPage 256
WSGPage 216
RTREPage 229
PRSPage 218
STL Page 229
S-ETPage 230
RTRDPage 230
3
Accessories
84
K-Fan
Rectangular & Square Duct Fans
MUB - Multibox Centrifugal fan
In-line discharge
to 90°
The MUB fans have impellers with backward curved blades, manufactured from aluminium except the 355 which ispolyamide. The MUB is equipped with external rotor motors or IEC standard motors, fully speed controllable. The three phase motors are D/Y connected for two speed operation. Motor protection is done by thermal contacts, which have to be connected to an external motor protection device. The casing consists of a corrosion-resistant aluminium frame with fibreglass reinforced plastic corners of PA6; highly shock-resistant. The double skin panels are manufactured from galvanised steel with 20 mm mineral wool insulation. To avoid condensation the profile is provided with a separate chamber to fix screws. The Multibox fans are delivered for straight through airflow but can easily be rebuilt due to removable panels. This allows flexible ventilation solutions. The MUB can also be used as extract or supply air unit in air handling units. Installation in any mounting position is possible. (* Power at Shaft)
Product Code SFP**
(kW/m3/s)
Airflow-
Straight
Speed
RPM
Airflow m3/sec @ Static Pressure Pa. Motor Data dBA
@
3m
Speed Control
Airflow 90º100 200 300 400 500 FLC kW Elec Trans
Single Phase Standard
MUB 025 355E4-A2 0.65 Straight 1260 0.551 0.43 0.096 - - 1.05 0.25 55 STL 1.5 RTRE 1.5
0.64 90º 0.636 0.50 0.288
MUB 042 400E4-A2 0.75 Straight 1360 0.92 0.80 0.64 0.26 - 2.2 0.373 49 STL 3.0 RTRE 3
0.83 90º 0.89 0.77 0.63 0.37
MUB 042 450E4-A2 0.99 Straight 1280 1.236 1.05 0.852 0.56 - 2.8 0.640 52 STL 5.0 RTRE 5
0.92 90º 1.32 1.10 0.912 0.68 -
MUB 042 499E4-A2 1.19 Straight 1320 1.50 1.306 1.09 0.85 0.482 4.95 1.10 48 STL 10.0 RTRE 5
1.09 90º 1.65 1.446 1.235 1.01 0.72
MUB 042 500E4-A2 1.15 Straight 1340 1.73 1.57 1.38 1.16 0.85 4.80 1.080 56 STL 10.0 RTRE 7
1.21 90º 1.958 1.748 1.54 1.32 1.107
Three Phase Standard
MUB 025 355DV-A2 0.68 Straight 1300 0.52 0.38 - - - 0.58 0.207 55 RTRD2
0.6 90º 0.606 0.469 0.11 - -
MUB 042 400DV-A2 0.69 Straight 1340 0.906 0.771 0.59 0.09 - 0.7 0.305 49 RTRD2
0.66 90º 0.96 0.80 0.605 0.22 -
MUB 042 450DV-A2 0.84 Straight 1230 1.246 1.085 0.893 0.595 - 1.3 0.69 52 RTRD2
0.87 90º 1.375 1.178 0.973 0.753 0.184
MUB 042 499DV-A2 0.97 Straight 1200 1.408 1.216 0.998 0.694 0.199 1.8 0.9 48 RTRD2
1.65 90º 1.548 1.316 1.084 0.812 0.453
MUB 042 500DV-A2 1.18 Straight 1330 1.843 1.686 1.529 1.329 1.054 4.3 1.5* 56 RTRD7
1.26 90º 1.983 1.779 1.585 1.415 1.219
MUB 062 560DV-A2 1.32 Straight 1420 2.763 2.571 2.38 2.197 2.02 5.8 2.2* 57 RTRD7
1.37 90º 3.048 2.8 2.51 2.28 2.048
MUB 062 630DV-B2 1.72 Straight 1340 3.514 3.341 3.172 3.000 2.776 9.2 3.42 69 RTRD14
1.69 90º 3.958 3.764 3.563 3.368 3.177
MUB 062 630D4-A2 1.8 Straight 1400 3.781 3.632 3.48 3.312 3.129 9.5 4.0* 69 Inverter
1.73 90º 4.316 4.137 4.000 3.772 3.584
MUB 100 630D4-L 1.84 Straight 1435 4.9 4.7 4.6 4.3 4.1 9.5 5.5 75 Inverter
1.73 90º 5.5 5.2 5.1 4.8 4.6
MUB 100 710D6-A2 0.99 Straight 954 3.8 3.5 3.2 2.7 2.1 5.16 2.46 60 RTRD7
0.98 90º 4.1 3.8 3.4 3.0 2.5
• Speed-controllable• Modular system (Penta-post construction)• Integral thermal contacts• Low sound level - Double Skin (Acoustic Insulated)• Flexible airflow direction due to removable panels • Installation in any mounting position• High temp Kitchen version & EC motor available
FGVPage 220
UGSPage 220
SRKGPage 222
WSDPage 218
MUB-SILPage 207
PRSPage 218
STL Page 229
RTRDPage 230
3
85
Rectangular & Square Duct Fans
K-FanMUB Fan Performance Curves
Airflow Straight ThroughMultibox Fan as per arrows
Airflow at 90º sideDischarge as per arrows
3
Accessories
86
K-Fan
Rectangular & Square Duct Fans
K-FanMUB Fan Dimensions
MUB Asq Bsq Csq øD øE kg
025 355 -A2 500 420 378 355 224 37
042 400 -A2 670 590 548 400 253 58
042 450 -A2 670 590 548 454 286 54
042 499 -A2 670 590 548 504 321 66
042 500 -A2 670 590 548 504 321 68
062 560 -A2 800 720 676 570 361 130
062 630 -B2 800 720 678 635 407 145
062 630 -A2 800 720 678 635 407 135
100 630 D4-L 1000 920 878 630 389 160
100 710 -A2 1000 920 878 715 460 160
MUB Changing of air flow direction
FGV
TYPICAL ACCESSORIES AVAILABLE
WSG
SRKG
UGS
MUB
WSD
SRKG
UGS
FGV
UGSPage 220
SRKGPage 222
WSDPage 218
MUB-SILPage 207
PRSPage 218
STL Page 229
WSGPage 216
RTRDPage 230
3øEøD�C
�B�A
�A
87
Rectangular & Square Duct Fans
K-FanMultibox AHU
Filter sectionPanel FiltersBag Filters
Carbon Filters
Cooling Coil sectionChilled Water
DX Coil
Heating Coil sectionLPHW BatteryElectric Battery
Mixing Box section Heat Recovery section
Multibox Fan sectionShowing Louvre outlet& pre wired motor to
external isolator
Multibox Air Handling UnitsThe Multibox can be used as a standard extract fan or you can build your own air handling unit
with the components below. Units can be either supplied in sections or built in one piece.Please enquire for technical selections
Multibox AHU
3
Control Panels
7
Multibox „MUB“
• Im Gehäuse eingebautes, frei-laufendes Motorlüfterrad aus Aluminium
• Einseitig saugend, rückwärts gekrümmte Laufradschaufeln
• Direktantrieb mit innenliegen-dem Außenläufermotor, 0 - 100 %, elektronisch und trans-formatorisch steuerbar
• IEC-Standard-Normmotor bzw. spannungssteuerbarer Norm-motor
Motor und Laufrad sind statisch und dynamisch ausgewuchtet (Q=6,3 nach VDI 2060). Es ist ein Motorschutz über Thermo-kontakte bzw. über Kaltleiter möglich. Die Motor-Laufradein-heit wird auf einer Konsole aus verzinktem Stahlblech und Be-festigungsschienen im Gehäuse befestigt. Die Einströmung er-folgt über ein Einlassblech mit integrierter, tiefgezogener Ein-strömdüse.
• Singleplug lers, i
• Direct motor, 0 - lable, eformers
• IEC standard mototor speed contro
• The unit is mainpre-wired to a
The motor and anced together ynamically (Q= VDI 2060). The protected by ther cold conductors. The motor impeller is fixed on a mounting bracket and mount-ing rails inside the casing which is manufactured from galvanised steel. The air inlet is through an inlet panel with integrated inlet cone.
WRG
Als preiswerte Lösung zur Rege-lung und Steuerung von einfachen Standardlüftungsanlagen wurde die Schaltschrankreihe “Syste-matic F/K” entwickelt.
Grundausführung:• 5-stufige Drehzahlsteuerung für
die Ventilatoren• Pumpensteuerung für den Er-
hitzer• Frostschutzschaltung• Klappensteuerung• Temperaturregelung, stetig auf
Erhitzerventil wirkend• ZentralentriegelungWeiteres Zubehör und Einbautei-le auf Anfrage.
Our newly developed controller „Systematic F/K“ is an easy and competitive solution for control-ling standard air handling units.
Basic model:• 5-step transformer to control
the fan speed• Contolling the pump for the wa-
ter heating battery• Frost protection• Damper regulation• Temperature regulation control-
ling to the valve of the heating battery
• Central unlockingOther accessories and compo-nents on request.
Regelungs und Steuerung „Systematic F/K“ /Control panel „Systematic F/K“
88
K-Fan
Rectangular & Square Duct Fans
KVD / KVB - Single Box Fans
KVD (direct driven) and KVB (belt driven) from sizes 7/7 to 12/12 are a range of single skin supply or extract box fans for inline application. These fans are designed for cost effective installations with low to medium pressure drop whilst keeping very good sound performances.
Features & benefitsRobust and quiet operation thanks to the galvanized steel fan and motor support mounted on 4 anti-vibration rubber plots. Outlet connected to the casing through an 18 mm thick rubber joint acting as a flexible seal.
Reinforced bottom panel giving the box fan more stability and mechanical resistance. Indoor and outdoor installation with the same standard unit. Easy to install with motor wired to the IP 55 connection box. KVB and KVD have a round inlet and square outlet.Efficient double inlet galvanized steel forward curved impeller balanced statically and dynamically. The KVB and KVD have a 3 year warranty. Airflows up to 50 000 m3/h are available upon request. Operates with air up to 50°C.
Belt driven KVB range is available for three phase 60 Hz operation.
AncillariesOutlet rain hood with bird net, ORHIntake silencer, LDCFast clamp, FKBack draft damper, RSKMaintenance switch, REVPressure switchAnti-vibration mounts
• KVD – Double inlet Direct Driven range with airflows from 700 to 7,500 m3/h. (0.2m3/s to 2.08m3/s)• IP 54 Class Motors single phase except 12-12-D6 3phase.• KVB – Double inlet belt driven range with airflows from 700 to 13,000 m3/h (0.2m3/s to 3.60m3/s)• IP 55 Class F motors.• Casing in galvanized steel with standard roof and feet for
outdoor installation
RetailHospitalsIndustry
3
89
Rectangular & Square Duct Fans
K-FanKVD / KVB Double Inlet Box Fans Technical Data
KVB Belt driven IEC Motor IP 55 F Class
Motor kW Max V Hz Motor Wiring Wiring Weight (kg)
kW Amp
Min - Max m3/h r.p.m 1 speed 2 speed Min - Max
7/7 0.25 - 0.55 2800 400 50/60 1450 13a 14a 32 - 37 0.25 0.8
9/7 0.25 - 1.1 4100 400 50/60 1450 13a 14a 44 - 52 0.37 1.1
9/9 0.25 - 1.1 4500 400 50/60 1450 13a 14a 45 - 53 0.55 1.5
10/8 0.25 - 1.5 5100 400 50/60 1450 13a 14a 50 - 59 0.75 1.9
10/10 0.25 - 1.5 6200 400 50/60 1450 13a 14a 54 - 60 1.1 2.6
12/9 0.25 - 2.2 6800 400 50/60 1450 13a 14a 71 - 87 1.5 3.5
12/12 0.25 - 2.2 9000 400 50/60 1450 13a 14a 73 - 89 2.2 4.9
KVD Direct driven
SizeWatts Max m3/h Amps
(max m3/h)V/Hz r.p.m max IP Wiring
diagramLpa 1m Weight
(kg)
7-7-E4 (146 W) 146 1700 2.2 230/50 1410 54 1 58 20
7-7-E6 (73W) 73 1685 1.1 230/50 880 54 1 54 20
9-7-E4 (373W) 370 2750 4 230/50 1410 54 1 61 30
9-7-E6 (237 W) 237 2510 2.5 230/50 950 54 1 59 30
9-9-E4 (550 W) 550 3150 5.9 230/50 1450 54 1 64 32
9-9-E6 (237 W) 237 2590 2.4 230/50 950 54 1 61 31
10-8-E6 (237 W) 237 2550 3 230/50 950 54 1 63 35
10-10-E4 (550W) 550 3250 6 230/50 1425 54 1 66 37
10-10-E6 (237W) 237 2700 3.1 230/50 950 54 1 63 36
10-10-E6 (550W) 525 4825 5.7 230/50 950 54 1 65 42
12-9-E6 (736W) 736 4820 8.5 230/50 950 54 1 62 50
12-12-E6 (525W) 525 4400 6.4 230/50 950 54 1 64 50
12-12-E6 (736W) 736 5750 9.8 230/50 910 54 1 67 52
12-12-D6 (1380W) 1380 7150 5.1 400/50 925 54 13a 71 52
Gre
en/y
ello
w
Blac
k
Deltaconnection
Starconnection
Wiring 1. 230V Single speed
Wiring 13a.400V Single speed
Blue
Electrical wiring
Wiring 14a.400V Two speed
3
Quick Selection Tabulated Tables on page 98 & 99
90
K-Fan
Rectangular & Square Duct Fans
K-FanKVD / KVB Double Inlet Box Fans Dimensions
KVD Direct driven single skin
A A’ A’’ B B’ C D E øF
7-7 498 458 454 457 415 442 273 253 200
9-7 548 508 504 507 465 532 336 304 250
9-9 548 508 504 507 465 532 336 304 250
10-8 648 608 604 607 565 592 371 330 300
10-10 648 608 604 607 565 592 371 330 300
12-9 698 658 654 657 615 642 434 382 350
12-12 698 658 654 657 615 642 434 382 350
A''
A
A'
FE
KVB Belt driven single skin
A A’ A’’ B B’ C D E øF
7-7 598 558 555 457 412 441 273 253 250
9-7 748 708 705 562 512 541 336 304 300
9-9 748 708 705 562 512 541 336 304 300
10-8 798 758 755 657 612 591 371 330 350
10-10 798 758 755 657 612 591 371 330 350
12-9 948 908 905 812 762 691 434 382 400
12-12 948 908 905 812 762 691 434 382 400
B'
øF
B
D
C
All dimensions in mm
3
91
Rectangular & Square Duct Fans
K-FanKPB - Double Inlet Forward Curved Fan
The KPB from size 15/11 to 18/18 are a range of supply or extract box fan for inline or 90° application. The casing is made of an aluminum frame with single skin or double skin galvanized steel panels. These fans are designed for indoor and outdoor installations with low to medium pressure drop whilst keeping very good sound per-formances.
Features & benefitsRobust and quiet operation thanks to the galvanized steel fan and motor support mounted on 4 anti-vibration rubber plots.
Low noise level: Anti-vibration rubber adjustable feet are fitted below the fan casing. Outlet connected to the casing
through an 18 mm thick rubber joint acting as a flexible seal.Quality casing with aluminum profile structure, plastic corners, M1 fire rated 15 mm isolation through polyurethane foam.Easy access: A maintenance access door on the side is fitted with polyamide hinges and ¼ turn lock and key.Easy to install with motor wired to the IP 55 connection box.Efficient double inlet galvanized steel forward curved impeller balanced statically and dynamically. Inlet panel of KPB is to be ordered withrectangular inlet, damper or closed. The outlet is square. The KPB have a 2 year warranty.
On request, the KPB are available with:- PVC Coating for sea-side location- Double skin panels- EU4 Filter guided through rails for
easy maintenance and fitted inside the casing (with pressure sensor as an option).
AncillariesOutlet/inlet rain hood with net, ORH/IRHEU4 Filter Weather roof, WSDMaintenance switch, REVDamper (manual/motorized)Pressure switchSpecial executionsTwin fans 60 Hz three phase
• KPB – Double inlet belt driven range with airflows from 10,000 to 19,500 m3/h (2.77m3/s to 5.41m3/s)• IP 55 F Class IEC motors (380 V 50 and 60 Hz).• Suitable for operating temps of up to 50°C.• Casing with aluminium profile 15 mm polyurethane foam isolation• Suitable for mounting Outside.
RetailHospitalsIndustry
3
Deltaconnection
Starconnection
Wiring 13a.400V Single speed
92
K-Fan
Rectangular & Square Duct Fans
KPB Double Inlet Forward Curved Fan Technical Data
KPB Belt driven Inlet options
KPB Belt driven Manual damper Rectangular inlet
A B C D E F L Length H Height L Length H Height
DA 15-11 1000 950 800 508 443 128 800 672 890 740
DA 15-15 1000 950 800 508 443 128 800 672 890 740
DA 18-13 1150 1100 1000 594 518 120 900 800 1000 900
DA 18-18 1150 1100 1000 594 518 120 900 800 1000 900
Dimensions
Wiring diagram
B
D
A
EF
C
IEC Motor IP55 F Class
1 speed 2 speeds
kW Amp kW
4/8 poles
0.25 0.8 –
0.37 1.1 –
0.55 1.5 0.55/0.09
0.75 1.9 0.75/0.12
1.1 2.6 1.1/0.18
1.5 3.5 1.5/0.25
2.2 4.9 2.2/0.37
3 6.7 3/0.55
4 8.4 4/0.75
5.5 11.3 5.5/1.1
7.5 14.8 7.5/1.5
KPB Belt driven
Motor kW
Max m3/h V Hz Motor r.p.m.
Weight (kg)
Min - Max Min - Max
15/11 0.25 - 3 9500 400 50/60 1450 98 - 122
15/15 0.25 - 3 12800 400 50/60 1450 112 - 136
18/13 0.25 - 7.5 15500 400 50/60 1450 130 - 180
18/18 0.25 - 7.5 19500 400 50/60 1450 139 - 189
All dimensions in mm
Wiring 14a.400V Two speed
ORH, outlet rain hood with bird netIRH, inlet rain hood with bird net
Filter
3
93
Rectangular & Square Duct Fans
K-FanKVD / KPD DUO Direct Drive Performance Curves
Quick Selection Tabulated Tables on page 98 & 99
3
94
K-Fan
Rectangular & Square Duct Fans
KVD / KPD DUO Direct Drive Performance Curves
E6 (237W)
E6 (237W)
E6 (525W)
E6 (525W)
E6 (525W)
E6 (525W)
E6 (736W)
E6 (736W)
D6
D6
E6
E6
Do not select dotted area
Quick Selection Tabulated Tables on page 98 & 99
3
D6
E6 (736W)
E6 (525W)
95
Rectangular & Square Duct Fans
K-FanKVB / KPB DUO Belt Driven Fan Performance Curves
10
20
30
40
50
60
150140130120110100
90
80
70
70504030201054321pd (mm H O)2
C (m/s)2 302015105432
310046%
η50% 49%
45%
39%
800
1000
1200
1400
1600
1800
2000
2200
2400
2800
500 000500040003000200510001052V(m /h)3
7-7
10
20
30
40
50
60
150140130120110100
90
80
70
70504030201054321pd (mm H O)2
C (m/s)2 30 402015105432
60% 67% 70% 69% 63%53%
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1800
2000
2400
1000 1500 0000100080006000400030002005V(m /h)3
η
9-9
10
20
30
40
50
60
150140130120110100
90
80
70
70504030201054321pd (mm H O)2
C (m/s) 4030201510543
2000
2400
59%65% 67% 65% 60%
51%
700
600
800
900
1000
1100
1200
1300
1400
1600
1800
1000 1500 0000100080006000400030002005V(m /h)3
η
9-7
10
20
30
40
50
60
150140130120110100
90
80
70
70504030201054321pd (mm H O)2
C (m/s) 30 402015105432
60%66%
69%68%
62%
52%
600
700
800
900
1000
1100
1200
1300
1400
1700
1800
2200
1600
1500
1000 1500 0000100080006000400030002005V(m /h)3
η
10-8
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
10 = 100Pa40 = 400Pa100 = 1000Pa
3
To select duty:- Plot airflow in m3/hr, then read bottom table to get Dynamic pressure, which needs to be added onto your design static pressure to give Total pressure. Read off the RPM speed at which the fan will need to run and select the required motor size (move up to the nearest size as specified in previous pages i.e 0.25 0.37 0.55 etc. Typical fan Reference - KPB 9-9/0.37/1000 Please note that Resistance pressure is in mmH20 which x10 = Pa i.e 10mmH20 = 100Pa
96
K-Fan
Rectangular & Square Duct Fans
KVB / KPB DUO Belt Driven Performance Curves
10
20
30
40
50
60
150140130120110100
90
80
70
70504030201054321pd (mm H O)2
C (m/s)2 302015105432
60%64%
65%62% 56%
47%
600
700
800
900
1000
1100
1200
1400
1500
1600
1300
1700
1800
2200
1000 1500 0000100080006000400030002005V(m /h)3
η
10-10
10
20
30
40
50
60
150140130120110100
90
80
70
65%69%
68% 60%
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1800
70504030201054321pd (mm H O)2
C (m/s)2 30 402015105432000 30001000 1500 4000 6000 8000 10000 15000 20000V(m /h)3
η
12-12
10
20
30
40
50
60
150140130120110100
90
80
70
72%
74%73% 67%
56%
800
700
600
500
900
1000
1100
1200
1300
1400
1600
1800
70504030201054321pd (mm H O)2
C (m/s)2 30 402015105431500 2000 000410000100080006000400030001057V(m /h)3
η
12-9
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
10 = 100Pa40 = 400Pa100 = 1000Pa
Quick Selection Tabulated Tables on page 98 & 99
3
97
Rectangular & Square Duct Fans
K-FanKPB / KPB DUO Belt Driven Performance Curves
10
20
30
40
50
60
150140130120110100
90
80
70
58%64% 65%
62% 54%
400
500
600
700
800
900
1000
1100
1200
1400
70504030201054321pd (mm H O)2
C (m/s)2 30 402015105433000 4000 000030000200051000010008000600020051V(m /h)3
η
15-15
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
40002000 3000 8000 1500010000 0000400003000020006
10
20
30
40
50
60
150140130120110100
90
80
70
73%70% 63%
52%
300
350
400
450
500
600
700
800
900
1000
1200
70504030201054321pd (mm H O)2
C (m/s) 30 40201510543V(m /h)3
η
18-13
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
40002000 3000 8000 1500010000 0000400003000020006
10
20
30
40
50
60
150140130120110100
90
80
70
70%73%
71%64%
350
400
450
500
600
700
800
900
1000
1200
70504030201054321pd (mm H O)2
C (m/s)2 30 40201510543V(m /h)3
η
18-18
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
10
20
30
40
50
60
150140130120110100
90
80
70
64% 66%
64% 58%
400
500
600
700
800
900
1000
1100
1200
1400
70504030201054321pd (mm H O)2
C (m/s) 30 4020151054322000 30001000 1500 4000 6000 8000 10000 15000 20000V(m /h)3
η
15-11
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
10 = 100Pa40 = 400Pa100 = 1000Pa
10 = 100Pa40 = 400Pa100 = 1000Pa
3
NOT USABLENOT RECOMMENDEDNOT RECOMMENDED
98
KVD Direct drivenKPD DUO Twin Fan
Motor Speed Airflow m3/sec @ Static Pressure Pa. Speed Control
Auto Changeover
Panel DUO FanSize
Watts r.p.m max 50Pa 100Pa 150Pa 200Pa 250Pa 300Pa Trans
7-7-E4 (146 W) 146 1410 0.456 0.435 0.416 0.374 - - RTRE3.0 ACO8A
7-7-E6 (73W) 73 880 0.415 - - - - - RTRE1.5 ACO8A
9-7-E4 (373W) 370 1410 0.83 0.82 0.795 0.77 0.73 0.70 RTRE5.0 ACO8A
9-7-E6 (237 W) 237 950 0.66 0.60 0.53 RTRE3.0 ACO8A
9-9-E4 (550 W) 550 1450 1.00 0.97 0.95 0.92 0.85 0.80 RTRE7.0 ACO8A
9-9-E6 (237 W) 237 950 0.65 0.63 0.57 - - - RTRE3.0 ACO8A
10-8-E6 (237 W) 237 950 0.67 0.64 0.60 0.53 - - RTRE5.0 ACO8A
10-10-E4 (550W) 550 1425 1.00 0.97 0.95 0.92 0.90 0.85 RTRE7.0 ACO8A
10-10-E6 (237W) 237 950 0.72 0.66 0.60 0.48 - - RTRE5.0 ACO8A
10-10-E6 (550W) 525 950 1.25 1.15 1.05 0.86 - - RTRE7.0 ACO8A
12-9-E6 (736W) 736 950 1.31 1.27 1.24 1.18 1.10 0.96 RTRE12.0 ACO8A
12-12-E6 (525W) 525 950 1.18 1.16 1.13 1.07 0.95 - RTRE7.0 ACO8A
12-12-E6 (736W) 736 910 1.55 1.50 1.44 1.34 1.20 - RTRE12.0 ACO8A
12-12-D6 (1380W) 1380 925 1.90 1.80 1.70 1.60 1.47 - RTRD7.0 ACO/TO/ADS/3
Rectangular & Square Duct Fans
Quick Selection Data
Fan Ref Airflow m3/sec @ TOTAL Pressure Pa. Motor Data 400V - 50Hz - 3Ph
KVB, KPB Single Fan
KPB DUO Twin Fan
200 300 400 500 600 700 800 900 kW Amps ACOPKPB DUO Fan
KVB 7-7 KPB DUO 7-7 0.52 0.40 0.25 - - - - - 0.37 1.1 ACO/TO/ADS/3
0.69 0.56 0.45 0.30 - - - - 0.55 1.5 ACO/TO/ADS/3
- 0.75 0.64 0.55 0.43 - - - 0.75 1.9 ACO/TO/ADS/3
KVB 9-7 KPB DUO 9-7 0.66 0.53 0.38 - - - - - 0.37 1.1 ACO/TO/ADS/3
0.83 0.72 0.58 0.45 - - - - 0.55 1.5 ACO/TO/ADS/3
- 0.90 0.83 0.72 0.61 - - - 0.75 1.9 ACO/TO/ADS/3
- 1.04 1.00 0.93 0.83 0.72 - - 1.1 2.6 ACO/TO/ADS/3
- - - - - 1.00 - - 1.5 3.5 ACO/TO/ADS/3
KVB 9-9 KPB DUO 9-9 0.75 0.58 0.34 - - - - - 0.37 1.1 ACO/TO/ADS/3
0.94 0.83 0.66 0.45 - - - - 0.55 1.5 ACO/TO/ADS/3
1.16 1.02 0.92 0.78 0.61 - - - 0.75 1.9 ACO/TO/ADS/3
- 1.25 1.14 1.00 0.88 0.77 - - 1.1 2.6 ACO/TO/ADS/3
- - - - 1.20 1.11 - - 1.5 3.5 ACO/TO/ADS/3
KVB 10-8 KPB DUO 10-8 0.75 0.52 - - - - - - 0.37 1,1 ACO/TO/ADS/3
0.97 0.80 0.61 - - - - - 0.55 1.5 ACO/TO/ADS/3
1.16 1.05 0.90 0.75 0.52 - - - 0.75 1.9 ACO/TO/ADS/3
- 1.25 1.13 1.02 0.83 0.67 - - 1.1 2,6 ACO/TO/ADS/3
- - - - 1.25 1.11 0.94 - 1.5 3.5 ACO/TO/ADS/3
- - - - - 1.38 1.30 - 2.2 4.9 ACO/TO/ADS/3
KVB 10-10 KPB DUO 10-10 0.75 0.50 - - - - - - 0.37 1.1 ACO/TO/ADS/3
1.00 0.77 0.58 0.40 - - - - 0.55 1.5 ACO/TO/ADS/3
1.25 1.02 0.89 0.72 0.55 - - - 0.75 1.9 ACO/TO/ADS/3
1.38 1.27 1.11 0.97 0.78 0.64 - - 1.1 2.6 ACO/TO/ADS/3
- 1.61 1.41 1.30 1.16 1.00 0.88 - 1.5 3.5 ACO/TO/ADS/3
- - - - 1.50 1.38 1.25 - 2.2 4.9 ACO/TO/ADS/3
KVB 12-9 KPB DUO 12-9 0.86 0.55 - - - - - - 0.37 1.1 ACO/TO/ADS/3
1.14 0.88 0.61 - - - - - 0.55 1.5 ACO/TO/ADS/3
1.44 1.25 1.04 0.75 - - - - 0.75 1.9 ACO/TO/ADS/3
1.66 1.47 1.27 1.02 0.86 - - - 1.1 2.6 ACO/TO/ADS/3
- 1.80 1.66 1.52 1.33 1.11 - - 1.5 3.5 ACO/TO/ADS/3
- - - 1.83 1.70 1.55 1.38 - 2.2 4.9 ACO/TO/ADS/3
3
99
Fan Ref Airflow m3/sec @ TOTAL Pressure Pa. Motor Data 400V-50Hz-3Ph
KVB, KPB Single Fan
KPB DUO Twin Fan
200 300 400 500 600 700 800 900 kW Amps ACOPKPB DUO
KVB 12-12 KPB DUO 12-12 0.75 - - - - - - - 0.37 1.1 ACO/TO/ADS/3
1.16 0.66 - - - - - - 0.55 1.5 ACO/TO/ADS/3
1.52 1.20 0.76 - - - - - 0.75 1.9 ACO/TO/ADS/3
1.72 1.52 1.16 - - - - - 1.1 2.6 ACO/TO/ADS/3
- 1.94 1.69 1.40 1.00 - - - 1.5 3.5 ACO/TO/ADS/3
- 2.30 2.17 1.97 1.73 1.41 - - 2,2 4.9 ACO/TO/ADS/3
- - - - 2.36 2.20 1.94 - 3.0 6.7 ACO/TO/ADS/3
KPB 15-11 KPB DUO 15-11 0.78 - - - - - - - 0.37 1.1 ACO/TO/ADS/3
1.11 0.75 - - - - - - 0.55 1.5 ACO/TO/ADS/3
1.44 1.16 0.86 - - - - - 0.75 1.9 ACO/TO/ADS/3
1.77 1.45 1.16 0.94 - - - - 1.1 2.6 ACO/TO/ADS/3
- 1.92 1.66 1.44 - - - - 1.5 3.5 ACO/TO/ADS/3
- - 2.10 1.88 1.66 - - - 2.2 4.9 ACO/TO/ADS/3
- - - 2.38 2.22 - - - 3.0 6.7 ACO/TO/ADS/3
KPB 15-15 KPB DUO 15-15 1.11 - - - - - - - 0.55 1.5 ACO/TO/ADS/3
1.74 1.05 - - - - - - 0.75 1.9 ACO/TO/ADS/3
2.08 1.52 - - - - - - 1.1 2.6 ACO/TO/ADS/3
2.52 2.22 1.69 - - - - - 1.5 3.5 ACO/TO/ADS/3
3.00 2.77 2.47 1.96 1.45 - - - 2.2 4.9 ACO/TO/ADS/3
- - 3.11 2.83 2.43 1.94 - - 3.0 6.7 ACO/TO/ADS/3
- - - - 3.27 2.91 2.52 - 4.0 8.4 ACO/TO/ADS/3
- - - - - - - 3.11 5.5 11.3 ACP/SD/ADS/3
KPB 18-13 KPB DUO 18-13 1.27 - - - - - - - 0.55 1.5 ACO/TO/ADS/3
1.86 1.30 - - - - - - 0.75 1.9 ACO/TO/ADS/3
2.22 1.75 - - - - - - 1.1 2.6 ACO/TO/ADS/3
2.91 2.44 1.94 - - - - - 1.5 3.5 ACO/TO/ADS/3
3.36 3.02 2.61 2.22 - - - - 2.2 4.9 ACO/TO/ADS/3
- 3.52 3.33 3.05 2.63 2.30 - - 3.0 6.7 ACO/TO/ADS/3
- - - - 3.47 3.13 2.80 2.50 4.0 8.4 ACO/TO/ADS/3
- - - - - - 3.61 3.33 5.5 11.3 ACP/SD/ADS/3
KPB 18-18 KPB DUO 18-18 1.88 - - - - - - - 0.75 1.9 ACO/TO/ADS/3
2.50 - - - - - - - 1.1 2.6 ACO/TO/ADS/3
3.33 2.50 - - - - - - 1.5 3.5 ACO/TO/ADS/3
4.16 3.44 2.63 - - - - - 2.2 4.9 ACO/TO/ADS/3
- 4.44 3.75 3.05 2.36 - - - 3.0 6.7 ACO/TO/ADS/3
- - - 4.30 3.61 3.05 - - 4.0 8.4 ACO/TO/ADS/3
- - - - 4.72 4.16 3.61 - 5.5 11.3 ACP/SD/ADS/3
- - - - - - - 4.44 7.5 14.8 ACP/SD/ADS/3
2 Speed Motors are available for KVB, KPB & KPB DUO models - see page 92 for details and refer to fan curves for selection
All models are suitable for both internal & external mounting
Rectangular & Square Duct Fans
Quick Selection Data
3
100
K-Fan
Rectangular & Square Duct Fans
KP DUO - Acoustic Twin Fan (Direct or Belt Driven)
The KP DUO is a range of acoustically treated in-line centrifugal twin fans for internal and external mounting with aluminum profile casing. The direct driven KPD DUO ranges from 700 to 7000 m3/h while the standard range belt driven KPB DUO reaches 19 500 m3/h. Static pressures up to 700 Pa.A rectangular inlet and outletallow an easy connection to ducts avoiding sudden pressure loss.9 sizes are available from 450 to 1000 mm height. Suitable for operations up to 50°C.
WarrantyKP DUO twin fans have a 2 year warranty
Features & BenefitsQuiet operation• Aluminumprofileheavydutycasing
with 15 mm isolation on galvanized steel panels
• Fanandmotorsupportedona
metallic frame with built in vibration isolationQuality impellers and motors• Highly efficient forward curved
double inlet galvanized steel impeller.• IP 55 F Class motors, belt driven
(three phase). Direct drive IP 54 F Class single phase except
12-12-D6.Easy installation & maintenance• IP 55 wired connection box for easy
wiring of the two motors.
• Maintenance access door with lock and key.
Special arrangements60 Hz three phase
Performances curvesBelt driven see pages 95-97Direct driven see pages 93-94Wiring diagrams pages 89 & 92
• KPB DUO – Double inlet belt driven range with airflows from 10,000 to 19,500 m3/h (2.77m3/s to 5.41m3/s) Run & Standby Fan
• KPD DUO – Double inlet direct driven range with airflows from 700 to 7,000 m3/h (0.2m3/s to 1.94m3/s) Run & Standby Fan
• Suitable for mounting Outside
RetailToilets SchoolsIndustry
3
Quick Selection Tabulated Tables on page 98 & 99
101
Rectangular & Square Duct Fans
K-FanKVB / KVD / KPB DUO Dimensions
KPB DUO Belt driven A B C D E
7/7 600 900 450 840 390
9/7 700 1100 550 1040 490
9/9 700 1100 550 1040 490
10/8 750 1300 600 1240 540
10/10 750 1300 600 1240 540
12/9 900 1600 700 1540 640
12/12 900 1600 700 1540 640
15/11 1000 1900 800 1840 740
15/15 1000 1900 800 1840 740
18/13 1150 2200 1000 2140 940
18/18 1150 2200 1000 2140 940
KPD DUO Direct driven A B C D E
7/7 450 900 450 840 390
9/7 500 1000 500 940 440
9/9 500 1000 500 940 440
10/8 550 1100 550 1040 490
10/10 550 1100 550 1040 490
12/9 630 1260 630 1200 570
12/12 630 1260 630 1200 570
AirflowSide view
Top view
3
102
K-Fan
Rectangular & Square Duct Fans
KVD / KVB / KPB / KPD DUO & KPB DUO - Specification Text
KVDDirect driven box fan for inline operation and suitable for outdoor installations fitted with a forward curve double inlet impeller and IP 54 F Class motors. The casing is made of 1 mm thick galvanized steel. The impel-ler shall be fitted on 4 anti-vibration rubber plots and its outlet connected with the casing through a 18 mm thick rubber joint. An IP 55 connection box is fitted on the casing for easy instal-lation.Maximum temperature of the transported air: 50°C
KVBBelt driven box fan for inline opertion and suitable for outdoor installations fitted with a forward curve double inlet impeller and IP 55 F Classmotors. The casing is made of 1 mm thick galvanized steel. The impeller and motor shall be fitted on agalvanized steel support with 4 anti-vibration rubber plots, the impeller’s outlet connected with the casing through a 18 mm thick rubber joint. An IP 55 connection box is fitted on the casing for easy installation. Maximum temperature of the transported air: 50°C
KPBBelt driven box fan for inline or 90° operation suitable for outdoor instal-lation fitted with a forward curve double inlet impeller and IP 55 F Class motors. The casing is made of aluminumprofile structure and 1 mm galvanized steel panels fitted with 15 mm M1 polyurethane foam insulation. A maintenance door with polyamide hinge and key is located on the side of the box. The impeller and motor shall be fitted on a galvanized steelsupport with 4 anti-vibration rubber plots and the impeller’s outlet connected with the casing through a 18 mm thick rubber joint. Maximum temperature of the transported air: 50°C
KPB DUOBelt driven twin fan for inlineoperation suitable for outdoorinstallation fitted with a forward curve double inlet impeller and IP 55 F Class motors. The casing is made of aluminum profile structure and 1 mm galvanized steel panels fitted with 15 mm M1 polyure-thane foam insulation.A maintenance door with polyamide hinge and key is located on the side of the box. The impeller and motor shall be fitted on a galvanized steel support with 4 anti-vibration rubber plots and the impeller’s outlet connected with the casing through a 18 mm thick rubber joint. Maximum temperature of the transported air: 50°C. An IP 55 connection box for both motors is fitted on the casing.
KPD DUODirect driven twin fan for inline operation suitable for outdoor installation fitted with a forward curve double inlet impeller and IP 55 F Class motors. The casing is made of aluminumprofile structure and 1 mm galvanized steel panels fitted with 15 mm M1 polyurethane foam insulation. A maintenance door with polyamide hinge and key is located on the side of the box. The impeller shall be fitted on a galvanized steel support with 4 anti-vibration rubber plots and its outlet connected with the casingthrough a 18 mm thick rubber joint. Maximum temperature of thetransported air: 50°C. An IP 55 connection box for both motors is fitted on the casing.
3
KP DUO
KPB