"REDBRICK" BUILDING ANNEX RENOVATION TAMPA, FLSTATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS FDMA PROJECT NUMBER 215004
PROJECT LOCATION: 2316 W LEMON STREET STREET, TAMPA, FL 33606
LOCATION MAP
N
SHEET INDEXGENERALG0.1 COVER SHEETG0.2 GENERAL INFORMATION AND ABBREVIATIONSG0.3 CODE ANALYSISLS1.1 FIRST FLOOR LIFE SAFETY PLANLS1.2 SECOND FLOOR LIFE SAFETY PLAN
CIVILC001 OVERALL EXISTING SITE PLANC002 SITE DEMO / EROSION CONTROL PLANC101 SITE DEVELOPMENT PLANC201 GRADING AND DRAINAGE PLANC301 UTILITY PLANC401 SITE DETAILS
ARCHITECTURALAD1.1 DEMOLITION FIRST FLOOR PLANAD1.2 DEMOLITION SECOND FLOOR PLANAD1.3 DEMOLITION ROOF PLANAD3.1 DEMOLITION BUILDING ELEVATIONSAD9.1 DEMOLITION FIRST FLOOR REFLECTED CEILING PLANAD9.2 DEMOLITION FIRST FLOOR REFLECTED CEILING PLANA1.1 FIRST FLOOR PLANA1.2 SECOND FLOOR PLANA2.1 ROOF PLANA3.1 RENOVATED BUILDING ELEVATIONSA4.1 BUILDING SECTION AND WALL SECTIONSA4.2 PORCH COLUMN AND BARRIER FENCEA4.3 ELEVATOR PLAN AND DETAILSA5.1 STAIR DETAILSA6.1 DOORS AND WINDOWSA6.2 DOOR AND STROREFRONT DETAILSA7.1 PARTITION TYPES AND UL505 1-HR CEILING-FLOOR ASSEMBLYA7.2 UL419 1-HR AND 2-HR WALL ASSEMBLYA7.3 PEI AER-09038 2-HR HORIZONTAL ASSEMBLYA8.1 ENLARGED TOILET ROOM AND BREAKROOM PLANSA8.2 ENLARGED TOILET ROOM PLANSA8.3 ENLARGED TOILET ROOM ELEVATIONSA9.1 FIRST FLOOR REFLECTED CEILING PLANA9.2 SECOND FLOOR REFLECTED CEILING PLANID1.0 FINISH SCHEDULESID2.0 FLOOR TRANSITIONS AND SIGNAGE
STRUCTURALS0.1 STRUCTURAL SYMBOLS AND LEGENDS0.2 GENERAL NOTESS0.3 GENERAL NOTES
5032 GODDARD AVENUE, SUITE A, ORLANDO, FL 32804TELEPHONE: (407)245-3660
ARCHITECTURAL GROUP, INC.
[email protected] FL. LIC. # AA0002264
PROJECT TEAM
Cocoa, Florida 32922
EB #0000015
874 Dixon Boulevard
Phone: 321-636-0274Fax: 321-639-8986www.tlc-engineers.com
VICINITY MAP
PROJECT LOCATIONN NTSTAMPA, FLORIDA
BUILDING DATA AND PROJECT DESCRIPTION
S0.4 WIND PRESSURE DIAGRAMS1.1 FOUNDATION PLANS1.2 SECOND FLOOR FRAMING PLANS1.3 ROOF FRAMING PLANS2.1 STRUCTURAL SECTIONS AND DETAILSS2.2 STRUCTURAL SECTIONS AND DETAILSS2.3 STRUCTURAL SECTIONS AND DETAILSS2.4 STRUCTURAL SECTIONS AND DETAILSS2.5 STRUCTURAL SECTIONS AND DETAILS
MECHANICALM0.1 MECHANICAL LEGEND AND NOTESMD1.1 MECHANICAL FIRST FLO0R DEMOLITION PLANMD1.2 MECHANICAL SECOND FLOOR DEMOLITION PLANM1.1 MECHANICAL FIRST FLOOR PLANM1.2 MECHANICAL SECOND FLOOR PLANM4.0 MECHANICAL DETAILSM4.1 MECHANICAL CONTROLSM5.0 MECHANICAL SCHEDULESM5.1 MECHANICAL LOAD CALCULATIONS
PLUMBINGP0.1 PLUMBING LEGEND, NOTES, AND SCHEDULESPD1.1 PLUMBING FIRST FLOOR DEMOLITION PLANPD1.2 PLUMBING SECOND FLOOR DEMOLITION PLANP1.1 PLUMBING FIRST FLOOR GRAVITY PLANP1.2 PLUMBING SECOND FLOOR GRAVITY PLANP2.1 PLUMBING FIRST FLOOR PRESSURE PLANP2.2 PLUMBING SECOND FLOOR PRESSURE PLANP3.0 PLUMBING RISER DIAGRAMSP4.0 PLUMBING DETAILS
FIRE PROTECTIONF0.1 FIRE PROTECTION LEGEND, NOTES AND DETAILSF1.1 FIRE PROTECTION FIRST FLOOR PLANF1.2 FIRE PROTECTION SECOND FLOOR PLAN
ELECTRICALE0.1 ELECTRICAL LEGEND AND NOTESE1.0 ELECTRICAL SITE PLANED1.1 FIRST FLOOR ELECTRICAL DEMOLITION PLANED1.2 SECOND FLOOR ELECTRICAL DEMOLITION PLANE1.1 FIRST FLOOR LIGHTING PLANE1.2 SECOND FLOOR LIGHTING PLANE2.1 FIRST FLOOR POWER AND SYSTEMS PLANE2.2 SECOND FLOOR POWER AND SYSTEMS PLANE3.1 ELECTRICAL ONE-LINE DIAGRAME4.1 ELECTRICAL SCHEDULESE4.2 PANEL SCHEDULESE5.1 ELECTRICAL DETAILSE5.2 ELECTRICAL DETAILS
PERMIT AND CONSTRUCT
1
2
GENERAL PROJECT DESCRIPTION:PROJECT INCLUDES A RENOVATION TO AN EXISTING HISTORIC BUILDING.
INTERIOR WORK:SCOPE OF WORK INCLUDES INTERIOR RENOVATIONS AND MINOR INTERIOR STRUCTURAL MODIFICATIONS (TO THE EXISTING INTERIOR LOAD BEARINGWALLS TO ALLOW FOR THE CONSTRUCTION OF A NEW AMERICAN'S WITH DISABILITIES ACT (ADA) COMPLIANT ELEVATOR, NEW LIFE SAFETYSTAIRWAY, AND ENLARGEMENT OF EXISTING SPACES FOR A NEW MULTI-PURPOSE HALL). INTERIOR RENOVATIONS INCLUDE RELOCATION AND BUILD-OUT FOR NEW ADA TOILET ROOMS AND ADA SHOWERS, AN SUPPLY AND WEAPON'S ARMORY, AND OFFICES. MECHANICAL WORK INCLUDES NEWHVAC SYSTEMS. PLUMBING WORK INCLUDES NEW PLUMBING WORK INCLUDES NEW SANITARY AND SUPPLY WATER LINES AND FIXTURES. NEWELECTRICAL WORK INCLUDES NEW POWER AND DATA SYSTEMS.
EXTERIOR WORK:THE EXTERIOR WORK IS LIMITED TO REPLACEMENT AND REPAIR OF WOOD ROT AND REPAIR TO DAMAGE OF EXISTING BRICK WORK. EXTERIORWINDOWS WILL BE REPLACED WITH NEW THERMALLY EFFICIENT WINDOWS AND NEW STOREFRONT FRAMES WILL MATCH CURRENT MULLIONPRESENTATION OF EXISTING. EXISTING EXTERIOR HOLLOW METAL DOORS WILL BE REFINISHED TO MATCH EXISTING.
SITEWORK:SITE WORK IS LIMITED TO REGRADING AND RE-PAVING OF DETERIORATED ASPHALT THAT OCCURS AT FRONT (WEST SIDE) OF BUILDING . PARKINGLOT STRIPING WILL ALSO BE IDENTIFIED OVER NEW RE-PAVING AND OVER EXISTING PAVING TO REMAIN. EXISTING DETERIOATED SIDEWALKS AROUNDTHE BUILDING WILL ALSO BE REPLACED. A NEW DECORATIVE SECURITY WALL AND FENCE WILL BE DESIGNED AND LOCATED ON N. HOWARD STREET(EAST SIDE) OF BUILDING ATHE THE INTERSECTION OF CASS STREET TO PREVENT VEHICLES FROM RUNNING INTO PROPERTY AND BUILDING (THEREHAVE BEEN TWO INCIDENTS IN PAST YEARS WHERE CARS HAVE CRASHED INTO THIS BUILDING). LANDSCAPING WILL BE PROVIDED, BUT MUST MEETTHE CRITERIA OF THE GOVERNMENTS FORCE PROTECTION / ANTI-TERRORISM CRITERIA.
SITE UTILITIES WORK:EXISTING SITE UTILITIES WILL BE REPLACED FROM BUILDING TO POINTS OF SERVICE DUE TO UNCERTAINTY OF CONDITION AND AGE OF SYSTEMS.
BUILDING DATA:ADDRESS:2316 W LEMON STREETTAMPA, FL 33606
LEGAL DESCRIPTION OF PROPERTY:ALL OF BLOCK 6, BENJAMIN'S 4TH ADDITION, ACCORDING TO MAP OR PLAT THEREOF AS RECORDED IN PLATBOOK 2, PAGE 60, OF THE PUBLIC RECORDS OF HILLSBOROUGH COUNTY, FLORIDA TOGETHER WITH VACATEDALLEY WAYS LYING WITHIN SAID BLOCK.
TOGETHER WITH:THE SOUTHWEST QUARTER (SW1/4) OF THE NORTHWEST QUARTER (NW1/4) OF SECTION TWENTY-THREE(23), TOWNSHIP TWENTY-NINE (29) SOUTH, RANGE EIGHTEEN (18) EAST, LESS RIGHTS OF WAY FOR EXISTINGSTREETS ALONG THE EXTERIOR BOUNDARIES OF SAID TRACT, SAID TRACT COMMONLY KNOWN AS FORTHOMER HESTERLY AND FORMALLY KNOWN AS BENJAMIN FIELD.
1
2
ARCHITECTURAL GROUP, INC.
A
B
C
1 2 3 4
D
E
F
G
H
5 6 7 8 9 10
J
K
L
M
11 12 13 14
PROJECT TITLE AND OWNERS NAME
CONSULTANTS
SEAL AND SIGNATURE
REVISIONS
DRAWN BY
CHECKED BY
JOB NUMBER
DATE
DRAWING TITLE
DRAWING NUMBER
SHEET OF
FL LIC. # AA0002264
5032 GODDARD AVENUEORLANDO, FLORIDA 32804(407) [email protected]
COPYRIGHT © 2015 MRI ARCHITECTURAL GROUP INC.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
15
15
06/22/15
PETER M. IKEGAMIAR0013065
8/9/
2015
12:
40:0
9 P
MC
:\Use
rs\P
Ikeg
ami\D
ocum
ents
\A4
-201
4 M
RI -
Pro
posa
ls\1
411
- Tam
pa A
rmor
y\D
MS
TAM
PA-
RED
BR
ICK
BU
ILD
ING
BID
AN
D R
ESPO
NS
E TO
BLD
G.rv
t
G0.1
RJV
PMI
FDMA PROJECT NO.215004
COVER SHEET
"RED BRICK"BUILDING ANNEXTAMPA NATIONALGUARD ARMORY
DEPARTMENT OFMILITARY AFFAIRSST AUGUSTINE, FLORIDA
PERMIT ANDCONSTRUCT
1 RESPONSE TO
BLDG DEPT
07-27-15
2 RESPONSE TO
FIRE MARSHAL
08-07-15
PLUMBING CALCULATIONS
PLUMBING CALCULATIONS: 2010 FBC PLUMBING CODE
BUSINESS OCCUPANCY (CALCULATED PER FLORIDA FIRE PREVENTION CODE AND FLORIDA BUILDING CODE) = 57 PEOPLE
MEN AND WOMEN WC = 1/25 FOR FIRST 50 AND 1/50 THERE AFTER:= (1/25 X 50) + (1/50 X 7 PEOPLE) = 2.14 TOTAL WCREQUIRED WC = 2 + 0.14 = 2.14 WC = 1.07 MENS WC AND 1.07 WOMENS WC
MEN AND WOMEN LAV = 1/40 FOR FIRST 50 AND 1/80 THERE AFTER:= (1/40 X 40) + (1/80 X 17 PEOPLE) = 1.21 TOTAL LAVSREQUIRED LAV = 1 + 0.21 = 1.21 LAV = 0.61 MEN LAV AND 0.61 WOMENS LAV
DRINKING FOUNTAINS = 1/100 = 57 X 1/100 = .57 DF
ASSEMBLY OCCUPANCY (175 PEOPLE):= 175 PEOPLE = 87.5 MEN AND 87.5 WOMEN
REQUIRED MEN WC = 1/125 = 1/125 X 87.5 = 0.7 MEN WCREQUIRED WOMEN WC = 1/65 = 1/65 X 87.5 = 1.34 WOMEN WCTOTAL LAV REQUIRED = 1/200 = 1/200 X 175 = 0.87 LAVREQUIRED MEN LAV = 0.44 MEN LAVREQUIRED WOMEN LAV = 0.44 WOMEN LAV
DF = 1/500 = 1/500 X 175 = 0.35 DF1 SERVICE SINK REQUIRED
REQUIRED AND PROVIDED TOILET FIXTURESMEN WC REQUIRED = 1.07 BUSINESS + 0.70 ASSEMBLY = 1.77 = MEN WC REQUIRED, 6 MEN WC PROVIDED
WOMEN WC REQUIRED = 1.07 BUSINESS + 1.34 ASSEMBLY = 2.41 WOMEN WC REQUIRED, 3 WOMEN WC PROVIDED
MEN LAV REQUIRED = 0.61 BUSINESS + 0.44 ASSEMBLY = 1.05 MEN LAV REQUIRED,3 MEN LAV PROVIDED
WOMEN LAV REQUIRED = 0.61 BUSINESS + 0.44 ASSEMBLY = 1.05 WOMEN LAV REQUIRED, 3 WOMEN LAV PROVIDED
SERVICE SINKS REQUIRED: 0 BUSINESS + 1 ASSEMBLY = 1 SERVICE SINKS REQUIRED, 1 SERVICE SINKS PROVIDED
DRINKING FOUNTAINS REQUIRED: 1 REQUIRED, 4 PROVIDED
SHOWERS REQUIRED: 0 SHOWER REQUIRED, 4 SHOWERS PROVIDED (2 MEN AND 2 WOMEN)
CODE DATACODE REFERENCE
OCCUPANCY CLASSIFICATIONFBC 2010, SECTION 304: BUSINESS OCCUPANCY WITH ASSEMBLY A-3 (ACCESSORY USE)
OCCUPIED AREA FIRST FLOOR: 3,515 SF = 874 SF ASSEMBLY + 2,858 SF + (657 SF TOILET ROOMS)OCCUPIED AREA SECOND FLOOR: 3,277 SF (OMITS STAIR AND ELEVATOR OPENINGS) + 2,815 SF +(462 SF TOILET ROOMS AND HVAC ROOM)
OCCUPANT LOAD FIRST FLOOR:BUSINESS OCCUPANCY = 2,858 SF X 1 PERSON/100 SF = 28.5= 29 PEOPLEASSEMBLY OCCUPANCY = 874 SF X 1 PERSON / 5 SF = 175 PEOPLE
OCCUPANT LOAD SECOND FLOOR:BUSINESS OCCUPANCY = 2,815 SF X 1 PERSON/100 SF = 28.1= 28 PEOPLE
TYPE OF CONSTRUCTIONFBC 2010, SECTION 602.5, TABLE 601 TYPE VB, SPRINKLERED
HEIGHT AND AREA LIMITATIONSFBC 2010, TABLE 503:MAXIMUM AREA = 9,000 SF, SECTION 503.3, SPRINKLEREDMAXIMUM HEIGHT = 2 STORIES
MAXIMUM TRAVEL DISTANCE:FBC 2010, TABLE 1016.1, OCCUPANCY B:SPRINKLERED = 300'-0"NON-SPRINKLERED = 200'-0"
SINGLE EXIT:75'-0"
DEAD ENDS: 20'-0" MAX
COMMON PATH OF TRAVELFBC 2010, SECTION 1014.3, = 75'-0"
LEVEL OF ALTERATION
EXISTING HISTORIC BUILDING:2-STORY - MASONRY LOAD BEARING WALLS, SECOND FLOOR WOOD STRUCTURE, PRE-ENGINEERED WOOD ROOF TRUSSES.
EXISTING BUILDING AREA = 3,515 SF FIRST FLOOR + 3,277 SF SECOND FLOOR = 6,792 SF
FBC 2010, SECTION 404: LEVEL 2
FIRE RESISTANCE RATING REQUIREMENTSFBC 2010, TABLE 601: NONE REQUIRED
FIRE SEPARATION RATINGSFBC 2010, TABLE 508.4: BUSINESS AND ASSEMBLY SEPARATION:1 HR SPRINKLERED2 HRS NON-SPRINKLERED.
VERTICAL SHAFTS: STAIRS AND ELEVATORS: 1 HR
FLORIDA BUILDING CODE FLORIDA BUILDING CODE 2010
LIFE SAFETY CODE FLORIDA BUILDING CODE 2010FLORIDA FIRE PREVENTION CODE 5TH EDITIONNFPA 1, LIFE SAFETY CODE 2012 EDITIONNFPA 101, LIFE SAFETY CODE 2012 EDITIONNFPA 10, INSTALLATION OF PORTABLE FIRE EXTINGUISHERS 2012 EDITIONNFPA 13, AUTOMATIC SPRINKLER SYSTEMS, 2010 EDITIONNFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES, 2010 EDITIONNFPA 72, NATIONAL FIRE ALARM CODE, 2012 EDITION
PLUMBING CODE FLORIDA PLUMBING CODE 2010
ELECTRICAL CODE FLORIDA BUILDING CODE 2010 / NATIONAL ELECTRIC CODE 2011
MECHANICAL CODE FLORIDA MECHANICAL CODE 2010
ACCESSIBILITY CODE FLORIDA ACCESSIBILITY CODE 2010
FBC 2010 SECTION 1021 "NUMBER OF EXITS"FBC 2010, SECTION 1021.2 "SINGLE EXITS" FROM SECOND STORY:TABLE 1021.2MAXIMUM NUMBER OF OCCUPANTS = 29 PEOPLEMAXIMUM TRAVEL DISTANCE = 75'-0" MAX.
2010 FLORIDA FIRE PREVENTION CODE38.2.4.3 A single exit shall be permitted for a room or area with a totaloccupant load of less than 100 persons, provided that all of the followingcriteria are met:(1) The exit shall discharge directly to the outside at the level of exitdischarge for the building.(2) The total distance of travel from any point, including travel within theexit, shall not exceed 100 ft (30 m).(3) The total distance of travel specified in 38.2.4.3(2) shall be on the samestory, or, if traversing of stairs is necessary, such stairs shall not exceed15 ft (4570 mm) in height, and both of the following also shall apply:(a) Interior stairs shall be provided with complete enclosures to separatethem from any other part of the building, with no door openings therein.(b) A single outside stair in accordance with 7.2.2 shall be permitted toserve all stories permitted within the 15 ft (4570 mm) vertical travellimitation.
THIS PROJECT WAS PRE-REVIEWED BY FOR ONE SECOND FLOOR EXIT:KARL K. THOMPSON, CFPSENGINEERING, IVBUREAU OF FIRE PREVENTIONDIVISION OF STATE FIRE MARSHAL200 E. GAINES STREETTALLAHASSEE, FL 32399-0342
FLORIDA PRODUCT APPROVAL
ROOF SYSTEM: EXISTING TO REMAIN
SOFFIT SYSTEM: EXISTING TO REMAIN
PARAPET COPINGS AND FLASHINGS: EXISTING TO REMAIN.
EXTERIOR WALL SYSTEMS: EXISTING TO REMAIN. REFER TOSTRUCTURAL DRAWINGS FOR WINDOW AND DOOR INFILLS WHEREUNITS ARE TO BE REMOVED.
EXTERIOR DOORS: EXISTING TO REMAIN
ALUMINUM REPLACEMENT WINDOWS WITH 1" INSUALTED LOW-EGLASS: REFER TO STRUCTURAL DRAWINGS FOR WIND PRESSURESCHEDULE.
YKK YVS-410 TUH SERIES IMPACT RATED, LARGE MISSILE SINGLE HUNGOPERABLE WINDOWS. FLORIDA PRODUCT APPROVAL FL12217-R2
YKK YFW-400 TUH SERIES IMPACT RATED, LARGE MISSILE HUNGWINDOWS. FLORIDA PRODUCT APPROVAL FL13239-R2
ALUMINUM LOUVERS:
GREENHECK MODEL EHH601D RAINPROOF WALL LOUVER. FLORIDAPRODUCT APPROVAL FL 10088.1, MIAMI DADE NOA 12-0830.08
ARMORY VAULT CLASSIFICATIONSELF CONTAINED AND FIRE RATED (INCLUDING ALL PENETRATIONS) FORHAZARD GROUP 2 CLASSIFICATION FOR EXPLOSIVES (EXCEPTION FROM H-1 OCCUPANCY FBC 307.3) FOR TYPES, QUANTITIES AND WEIGHTS OFAMMUNITION TO BE STORED: GSA AA-V-2737 Approved MEGAvault ModularVault Panel System Meeting Army Regulation AR 190-11, Physical Security ofArms, Ammo & Explosives. Panel thickness: 4", 2 HOUR FIRE SEPARATIONFROM BUSINESS OCCUPANCY.
FIRE SEPARATION FROM ARMORY VAULT AND BUSINESSOCCUPANCY:FBC SECTION 307.3 HIGH HAZARD GROUP 1 EXCEPTION TO PERMITTEDTO HAZARD GROUP 2. FIRE SEPARATION 2 HOURS PER TABLE 508.4HBUSINESS FROM H-2 = 2 HOURS FOR SPRINKLERD BUILDING.
1
1
1
1 ARCHITECTURAL GROUP, INC.
A
B
C
1 2 3 4
D
E
F
G
H
5 6 7 8 9 10
J
K
L
M
11 12 13 14
PROJECT TITLE AND OWNERS NAME
CONSULTANTS
SEAL AND SIGNATURE
REVISIONS
DRAWN BY
CHECKED BY
JOB NUMBER
DATE
DRAWING TITLE
DRAWING NUMBER
SHEET OF
FL LIC. # AA0002264
5032 GODDARD AVENUEORLANDO, FLORIDA 32804(407) [email protected]
COPYRIGHT © 2015 MRI ARCHITECTURAL GROUP INC.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
15
15
06/22/15
PETER M. IKEGAMIAR0013065
8/9/
2015
12:
40:1
0 P
MC
:\Use
rs\P
Ikeg
ami\D
ocum
ents
\A4
-201
4 M
RI -
Pro
posa
ls\1
411
- Tam
pa A
rmor
y\D
MS
TAM
PA-
RED
BR
ICK
BU
ILD
ING
BID
AN
D R
ESPO
NS
E TO
BLD
G.rv
t
G0.3
PMI
JLR
FDMA PROJECT NO.215004
CODE ANALYSIS
"RED BRICK"BUILDING ANNEXTAMPA NATIONALGUARD ARMORY
DEPARTMENT OFMILITARY AFFAIRSST AUGUSTINE, FLORIDA
PERMIT ANDCONSTRUCT
1 RESPONSE TO
BLDG DEPT
07-27-15
4. SEMI RECESSED FIRE EXTINGUISHER CABINETAND EXTINGUISHER PER NFPA 10, STANDARDFOR PORTABLE FIRE EXTINGUISHERS, LATESTEDITION
WALL MOUNTED FIRE EXTINGUISHER PERNFPA 10, STANDARD FOR PORTABLE FIREEXTINGUISHERS, LATEST EDITION
FEC
FE
1-HR FIRE-RATED WALL CONSTRUCTION
EXIT LIGHT
2. RECESSED FIRE EXTINGUISHER CABINET AND #10 ABC FIRE EXTINGUISHER PER LATESTEDITION NFPA 10, STANDARD FOR PORTABLEFIRE EXTINGUISHERS. ALL FE WITHINCORRIDORS AND LOBBIES SHALL BE IN A SEMI-RECESSED FIRE EXTINGUISHER CABINET. ALLFIRE EXTINGUISHERS IN STORAGE ROOMSSHALL BE SURFACE MOUNTED. FIREEXTINGUISHERS SHALL BE LOCATED SO THAT,FROM ANY POINT WITH IN THE BUILDING, THETRAVEL DISTANCE TO THE EXTINGUISHER ISLESS THAN 50'-0".
3.
5.
6.
1. FOR BUILDING CODE AND LIFE SAFETYINFORMATION AND PLUMBING CALCULATIONSSEE SHEET G0.3 CODE ANALYSIS.
P34"[864]
1707.EXIT UNIT WIDTH AND NUMBEROF PEOPLE EXIT WILLACCOMMODATE
EMERGENCY LIGHT. SEE ELECTRICAL8.
LIFE SAFETY NOTES
REFER TO ELECTRICAL SHEETS FORADDITIONAL LIFE SAFETY DEVICES NOTSHOWN ON THIS SHEET.
9.
750 SF HATCHED AREA750 SF / 7 SF PER PERSON = 107 PEOPLE
DRILL HALL108
3500 LBELEVATOR
103HVAC RM 1
107
IT110B
BREAKROOM106
W TLT104
M TLT101
HA SHWR101B
HA SHWR104A
BRICK WALLINFILLAND FINISHBRICK ATDEMOLISHED DOOR
SUPPLY114
SUPPLYDISTRIBUTION
111
HVAC114A
NEW STRUCTURAL BEAM
EXISTING BEARING WALLS TO REMAIN
EXISTING BEARING WALLS TO REMAIN
EXISTING BEARING WALLS TO REMAIN
EXISTINGOPENING INEXISTINGBEARINGWALL
NEWOPENING INEXISTINGBEARINGWALL
FIRE STAIRS100A
ARMORYVAULT
112
SUPPLY DISTRIBUTION COUNTER?
SUPPLY113
300 SF
STORAGE109
SUPPLY115
CORR102
ELECT110
NEW WINDOWAND BRICK INFILLBELOW INEXISTING DOOROPENING
FIRESPRINKLER
RISER105
109
115
114A
114
112
111A
108A
108B
100A
101
104
107
110B
106B
108C
100B
102
P54 27
0
P54 27
0P
34"
170
P34
"17
0
P34
"17
0
P34"170
FE
FE
FEC
FEC
BRICK WALLINFILLAND FINISHBRICK ATDEMOLISHED DOOR
PROPERTY LINE: REFER TO CIVIL DRAWINGS
AUTOMOTIVE BARRIER: REFER TO CIVIL DRAWINGS
EMERGENCYLIGHT ABOVE
EMERGENCYLIGHT ABOVE
EMER
GENC
YLIG
HT A
BOVE
EMER
GENC
YLIG
HT A
BOVE
EMER
GENC
YLIG
HT A
BOVE
EMER
GENC
YLIG
HT A
BOVE
EMER
GENC
YLIG
HT A
BOVE
EMERGENCY
LIGHT AB0V
E
EMERGENCYLIGHT AB0VENOTE: 2-HR UL 505 CEILING FLOOR
ASSEMBLY ABOVE SUSPENEDACOUSTICAL CEILING SYSTEM WITHINROOMS 100, 100A, 110 AND 110B.
THIS FLOOR ONLY: HATCHDENOTES 1-HOUR UL505 CEILING -FLOOR ASSEMBLY AT ROOM 108,110, 110B AND 100 (FIRST FLOORONLY)
THIS BUILDING WILL BE PROTECTEDBY A FIRE SPRINKLER SYSTEM
EM LI
GHT
111B
EMER
GENC
YLIG
HT A
B0VE
S-7 OCCUPANCY LOAD
RATED EXIT100
2
(2-HR D00R W/2-HR GLAZING)
2
ARCHITECTURAL GROUP, INC.
A
B
C
1 2 3 4
D
E
F
G
H
5 6 7 8 9 10
J
K
L
M
11 12 13 14
PROJECT TITLE AND OWNERS NAME
CONSULTANTS
SEAL AND SIGNATURE
REVISIONS
DRAWN BY
CHECKED BY
JOB NUMBER
DATE
DRAWING TITLE
DRAWING NUMBER
SHEET OF
FL LIC. # AA0002264
5032 GODDARD AVENUEORLANDO, FLORIDA 32804(407) [email protected]
COPYRIGHT © 2015 MRI ARCHITECTURAL GROUP INC.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
15
15
06/22/15
PETER M. IKEGAMIAR0013065
8/9/
2015
12:
40:1
2 P
MC
:\Use
rs\P
Ikeg
ami\D
ocum
ents
\A4
-201
4 M
RI -
Pro
posa
ls\1
411
- Tam
pa A
rmor
y\D
MS
TAM
PA-
RED
BR
ICK
BU
ILD
ING
BID
AN
D R
ESPO
NS
E TO
BLD
G.rv
t
LS1.1
PMI
JLR
FDMA PROJECT NO.215004
FIRST FLOOR LIFESAFETY PLAN
"RED BRICK"BUILDING ANNEXTAMPA NATIONALGUARD ARMORY
DEPARTMENT OFMILITARY AFFAIRSST AUGUSTINE, FLORIDA
PERMIT ANDCONSTRUCT
12'8'4'2'0
1/4" = 1'-0"
N
1/4" = 1'-0"LS1.1
A1 FIRST FLOOR LIFESAFETY PLAN
2 RESPONSE TO
FIRE MARSHAL
08-07-15
4. SEMI RECESSED FIRE EXTINGUISHER CABINETAND EXTINGUISHER PER NFPA 10, STANDARDFOR PORTABLE FIRE EXTINGUISHERS, LATESTEDITION
WALL MOUNTED FIRE EXTINGUISHER PERNFPA 10, STANDARD FOR PORTABLE FIREEXTINGUISHERS, LATEST EDITION
FEC
FE
1-HR FIRE-RATED WALL CONSTRUCTION
EXIT LIGHT
2. RECESSED FIRE EXTINGUISHER CABINET AND #10 ABC FIRE EXTINGUISHER PER LATESTEDITION NFPA 10, STANDARD FOR PORTABLEFIRE EXTINGUISHERS. ALL FE WITHINCORRIDORS AND LOBBIES SHALL BE IN A SEMI-RECESSED FIRE EXTINGUISHER CABINET. ALLFIRE EXTINGUISHERS IN STORAGE ROOMSSHALL BE SURFACE MOUNTED. FIREEXTINGUISHERS SHALL BE LOCATED SO THAT,FROM ANY POINT WITH IN THE BUILDING, THETRAVEL DISTANCE TO THE EXTINGUISHER ISLESS THAN 50'-0".
3.
5.
6.
1. FOR BUILDING CODE AND LIFE SAFETYINFORMATION AND PLUMBING CALCULATIONSSEE SHEET G0.3 CODE ANALYSIS.
P34"[864]
1707.EXIT UNIT WIDTH AND NUMBEROF PEOPLE EXIT WILLACCOMMODATE
EMERGENCY LIGHT. SEE ELECTRICAL8.
LIFE SAFETY NOTES
REFER TO ELECTRICAL SHEETS FORADDITIONAL LIFE SAFETY DEVICES NOTSHOWN ON THIS SHEET.
9.
FIRE STAIRS200
AGR RRNCOOFFICE
201
ADMINISTRATIONOFFICE
204
READINESSOFFICE
205
HVAC208
COMMANDMEETING
213
CDR OFFICE216
1SG OFFICE214
PLATOON AWORK ROOM
2063'-8" X 8'-0"CONFERENCETABLE
COPY /MAIL207
M TLT211
W TLT212
FILES / STO
PLATOON BWORK ROOM
209
XO OFFICE215
70'-0" TRAVEL DISTANCE TO PROTECTED 1- HR VERTICAL STAIRWAY(75'-0" MAX ALLOWED FOR SINGLE EXIT)
KEY
SAFE
S
2 HR FIRE RATEDGLAZING
2-HR FIRE RATEDGLAZING
LOBBY202
STOREFRONTWINDOW
MAINTENANCEOFFICE
203
EXISTING PORCH STANDING SEAM ROOF TO REMAIN(PROTECT FROM DAMAGE)
NEW GUTTERS AND DOWNSPOUTS AND FLASHINGS GUTTERNEW GUTTERS AND DOWNSPOUTS AND FLASHINGS TO GUTTER
215
200B
204B205
213
211
212
216
214
204A
200A
208
P34
"17
0
P34"170
FEC
FEC
STO210
203
201
FEC
(6 PEOPLE)
(1 PEOPLE) (1 PEOPLE)
(1 PEOPLE)
(5 PEOPLE)
(5 PEOPLE)
(1 PEOPLE) (1 PEOPLE) (6 PEOPLE)
(2 PEOPLE)
PROTECTED 2-HR VERTICAL STAIRWAY 78'-0"TRAVEL DISTANCE To EXTERIOR DOOR
HATCH THIS FLOOR ONLY DENOTES 2-HOUR HORIZONTAL SHAFT WALL CEILING ASSEMBLY(PROTECTED FROM TOP AND BOTTOM) BELOW EXISTING ROOF TRUSSES. BASIS OFDESIGN USG GYPSUM COMPANY: 20 GA 6" CH STUDS AT 24" O.C. WITH 1" FIRE CODE "C"CORE BOARD (TOP SIDE) AND TWO LAYERS 1/2" FIRE CODE "C" (BOTTOM SIDE): ICCEVALUATION REPORT NER-258 AND PROGRESSIVE ENGINEERING REPORT AER-09038.
THIS BUILDING WILL BE PROTECTED BY A FIRE SPRINKLER SYSTEM
EMERGENCYLIGHT ABOVE
EMER
GENC
YLIG
HT A
BOVE
EMER
GENC
YLIG
HT A
BOVE
EMER
GENC
YLIG
HT A
BOVE
EMER
GENC
YLIG
HT A
BOVE
EMERGENCYLIGHT ABOVE
EMERGENCYLIGHT ABOVE
EMERGENCYLIGHT AB0VE
EM LIGHT
EM LI
GHT
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
FIXEDWINDOW
FIXEDWINDOW
S-6
2
2
ARCHITECTURAL GROUP, INC.
A
B
C
1 2 3 4
D
E
F
G
H
5 6 7 8 9 10
J
K
L
M
11 12 13 14
PROJECT TITLE AND OWNERS NAME
CONSULTANTS
SEAL AND SIGNATURE
REVISIONS
DRAWN BY
CHECKED BY
JOB NUMBER
DATE
DRAWING TITLE
DRAWING NUMBER
SHEET OF
FL LIC. # AA0002264
5032 GODDARD AVENUEORLANDO, FLORIDA 32804(407) [email protected]
COPYRIGHT © 2015 MRI ARCHITECTURAL GROUP INC.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
15
15
06/22/15
PETER M. IKEGAMIAR0013065
8/9/
2015
12:
40:1
4 P
MC
:\Use
rs\P
Ikeg
ami\D
ocum
ents
\A4
-201
4 M
RI -
Pro
posa
ls\1
411
- Tam
pa A
rmor
y\D
MS
TAM
PA-
RED
BR
ICK
BU
ILD
ING
BID
AN
D R
ESPO
NS
E TO
BLD
G.rv
t
LS1.2
PMI
JLR
FDMA PROJECT NO.215004
SECOND FLOOR LIFESAFETY PLAN
"RED BRICK"BUILDING ANNEXTAMPA NATIONALGUARD ARMORY
DEPARTMENT OFMILITARY AFFAIRSST AUGUSTINE, FLORIDA
PERMIT ANDCONSTRUCT
12'8'4'2'0
1/4" = 1'-0"
N
1/4" = 1'-0"LS1.2
A1 SECOND FLOOR LIFESAFETY PLAN
2 RESPONSE TO
FIRE MARSHAL
08-07-15
UP
REF. REF.
874 SF HATCHED AREA874 SF / 5 SF PER PERSON = 175 PEOPLE
DRILL HALL108
3500 LBELEVATOR
103
HVAC RM 1107
IT110B
BREAKROOM106
W TLT104
M TLT101
HA SHWR101B
HA SHWR104A
SUPPLY114
SUPPLYDISTRIBUTION
111
HVAC114A
NEW STRUCTURAL BEAM
PROVIDE FURRED WALLTIGHT TO NEW COLUMN
24'-0" +/-
EXISTING BEARING WALLS TO REMAIN
EXISTING BEARING WALLS TO REMAIN
EXISTING BEARING WALLS TO REMAIN
EXISTINGOPENING INEXISTINGBEARINGWALL
NEWOPENING INEXISTINGBEARINGWALL
FIRE STAIRS100A
ARMORYVAULT
112
18' - 1"0' - 0" 16' -
8"
SUPPLY113
300 SF
STORAGE109
SUPPLY115
CORR102
ELECT110
8' - 4
"12
' - 4"
6' - 11" 2' - 8"
8' - 0" 10' - 0 1/2"
NEW WINDOW AND BRICKINFILL BELOW IN EXISTINGDOOR OPENING
2' - 8
"6'
- 4" 0'
- 10"
4' - 0
"
2' - 4"
FIRESPRINKLER
RISER105
4' - 5
1/2"
4' - 0
"8'
- 8 5/
8"4'
- 0"
8' - 1
0 1/8"
4' - 0
"4'
- 3 1/
4"
1' - 4
"
1' - 4"
2' - 0
"9'
- 2 1/
2"
3' - 10 7/8" 4' - 0" 6' - 7 1/4" 4' - 0" 5' - 3 1/8" 4' - 0" 3' - 9 1/4" 5' - 3"
3' - 9 1/4"
4' - 0" 5' - 3 7/8" 4' - 0" 4' - 7 3/4" 4' - 0" 5' - 3 1/2" 4' - 0" 3' - 9 1/2" 5' - 3" 3' - 10" 4' - 0" 4' - 1 1/2" 4' - 0" 4' - 0 1/2"
100' - 10 3/8"
7' - 4 7/8" 3' - 6" 2' - 9 5/8" 4' - 0" 2' - 0 1/8" 12' - 8 1/2" 3' - 10 1/8" 2' - 9 1/2" 4' - 0" 2' - 1" 3' - 10 1/8" 3' - 10 1/8" 2' - 9 7/8" 4' - 0"
3' - 1
1/2"
4' - 0
"2'
- 11 1
/2"4'
- 0"
3' - 1
3/4"
4' - 0
"3'
- 1 1/
2"3'
- 3 1/
2"10
' - 7 3
/4"
14' - 2 3/8" 14' - 2 1/4" 13' - 11 1/4" 13' - 11 1/4" 13' - 10 1/2" 13' - 10 1/4" 13' - 11 1/2" 0' - 9"0' - 10"
38' -
3 1/2"
3' - 4
"
1' - 4" 3' - 4" 5' - 4"
EQ EQ
9' - 4
"5'
- 8 1/
2"
109
115
114A
114
112
111A 10
8A
108B
100A
101
104
107
110B
106B
108C
100B
102
10
10
10B 10B
10B
10 10
10B
10
10B
10
6
6
10B
10B
10B
10B
10B10C
10
6
10
6D
1C
10
6C
6C
6C
6C
10B6B6B
13
136
1
1
6C
6C
10B
10B
10B
10
10B
10
10
10B
6B
6B
10B10B
6B
10
10B
10B
1010B 10B
10B
10B 10B
10B
10
10B
10B
30X4
8AD
ACL
R
30X4
8AD
ACL
R
30X4
8AD
ACL
R
30X4
8AD
ACL
R
30X4
8AD
ACL
R
1' - 11 3/4" 4' - 0" 1' - 10 3/4" 13' - 11 1/4"
ADA COMPLIANT
RELOCATED EXISTINGDRINKING FOUNTAIN. MOUNTPER ADA
105
CMUINFILL
106A
110
103
10' -
4"
2' - 9"4' - 0"
3' - 6
"
FIRE TREATEDPLYWOODFULL HEIGHT
HATCH DENOTES: 4'-0" X3'-0" CLEAR SPACE FORELEVATOR SERVICE
W3 W3 W3 W3 W3 W3 W3 W3 W3
W3
W3
W3
W3
W3W3W3W3W3W3W4
W1
W3
W2
W2
W1 W1
EXISTING DOORS AND FRAMESTO BE REFINISHED
EXISTING DOOR
6' - 0"10' -
0"
6' - 0"
REFE
R TO
CIV
IL DR
AWIN
GS1'
- 10"
4'-0"
+ MA
X
2' - 0
"4'
- 0"
PROPERTY LINE: REFER TO CIVIL DRAWINGS
ABI-1: DECORATIVE BARRIER WALL AND FENCE: REFER TO DETAILS A10 AND B10, SHEET A4.2 AND CIVIL DRAWINGS
PROVIDE FURRED WALLTIGHT TO NEW COLUMN
5' - 0"
JAN101A
101A
ALL WINDOW GLASS IN ALLTOILET ROOMS:PROVIDE TRANSLUCENTOBSCURE WINDOW FILM(INTERIOR SIDE) FORPRIVACY. SUBMIT SAMPLEFOR SELECTION
AT EXISTING DOOR AND FRAMETO BE REMOVED: PROVIDE NEWCMU AND BRICK INFILL TOMATCH EXISTING BRICK ANDPATTERNS
ALL WINDOW GLASS IN ALL TOILET ROOMS:PROVIDE TRANSLUCENT OBSCURE WINDOW FILM(INTERIOR SIDE) FOR PRIVACY. SUBMIT SAMPLEFOR SELECTION
AT EXISTING DOOR AND FRAME TO BE REMOVED:PROVIDE NEW CMU AND BRICK INFILL TO MATCHEXISTING BRICK AND PATTERNS
LANDING AND STEPS: CONSTRUCT LANDING AS DEEP AS POSSIBLE TO ACHIEVE 5'-0" DEPTH (FIELD VERIFYAGAINST EXISTING PROPERTY LINE AND PROPOSED SIDEWALK AND EXISTING SECURITY FENCE TO REMAIN)
6' - 0
"
REFRIGERATORS,GOVERNMENT FURNISHED,GOVERNMENT INSTALLED
S-5DIRECTORY
S-3
S-2
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
10
6
6
6
9
9
9
9
9
9
8
8
7 777777 777
7
7
7
7
7 7 7 7 7 7 7 7 7 7
11
7
7
7
7
7
S-1
S-1
10B
A8.1H8
A8.2A1
A1
A4.3
A10
A4.1
B10
A4.2
A3.1
A1
A3.1 J1
A3.1
E1
A3.1J8
W3 W1
6D6D
A4.2B1
A4.2B1
A4.2B1
A4.2B1
A4.2B1
A4.2B1
A4.2B1
A4.2B1
6' - 0
"
3' - 4
"
5' - 0"
2' - 0
"
3' - 0" CLR
9'-0"
+/-
1' - 0
"
1C
2' - 6"
10C
10C10
10B
10B
10B
3' - 0
" CLR
CLR
1' - 4
"
4'-8"+ 4' - 0" CLR
4' - 0
1/2"
4' - 0
"
3' - 0" CLR
4' - 4"4' - 0" CLR
6C6C
6
6D6C
CLR
3' - 0"6C
3' - 6" CLR
SLOPETO DRAIN
SLOPETO DRAIN
SLOPETO DRAIN
SLOPETO DRAIN
SLOPETO DRAIN
SLOPETO DRAIN
TRENCHDRAIN
SHWRCURTAIN
PARTITION
111B
S-7OCCUPANCYLOAD
7
RECYCLING10 SF
EM (LEED)
EM (LEED)
6' - 0
"
6' - 4
1/2"
1' - 6
"
EM (LEED)
RECY
CLIN
G20
SF
RECYCLING20 SF
RECYCLING20 SF
RECYCLING20 SF
3' - 8"
3' - 8
"
BOTTOM RAIL TOEXTEND BELOWSTAIR TO WALL
1' - 11"
5'-0".
5' - 7 1/4"
2'-6". 3'-1 1/4".
(2-HR D00R W/2-HR GLAZING)
RATED EXIT100
12"
2
100C
2-HR FIRE SEPARATION(INCLUDING PENETRATIONS)
1
1
1.
2.
3.
4.
6.
7.
8.
9.
10.
PARTITION TYPE (SEE A7.1)XX
STOREFRONT GLAZING TYPE(SEE SHEET A6.1)
XX
DOOR NUMBER (SEE SHEET A6.1)
SEE SHEET ID1.0 FOR ROOM FINISHSCHEDULES.
XXX
ALL DIMENSIONS TO FACE OF CONCRETEOR MASONRY AND TO FACE OF INTERIORMETAL STUD WALLS OR CENTER LINE OFCOLUMN UNLESS NOTED OTHERWISE.
1-HR FIRE-RATED WALL CONSTRUCTION
REFER TO LIFE SAFETY PLANS LS1.1 ANDLS1.2 FOR FIRE EXTINGUISHER CABINETAND WALL MOUNTED FIRE EXTINGUISHERS.
GENERAL CONSTRUCTION CONTRACTORSHALL PROVIDE ALL BLOCKING /SUPPORTS WITHIN WALLS AND ABOVECEILINGS FOR OWNER FURNISHEDFINISHES / MATERIALS, DEVICES ANDEQUIPMENT. ALL BLOCKING SHALL BE OFNON-COMBUSTIBLE MATERIAL. FIRETREATED LUMBER MAY BE USED IFPERMITTED BY BUILDING CODE ANDAGENCY HAVING JURISDICTION. ALLSUPPORTS SHALL BE FIELD LOCATED ANDAPPROVED BY THE GOVERNMENTREPRESENTATIVE PRIOR TO FINALINSTALLATION.GENERAL CONSTRUCTION CONTRACTORSHALL COORDINATE ALL TRADES ANDSHALL PROVIDE ELECTRICAL,MECHANICAL, PLUMBING SERVICES ANDHOOKUPS TO OWNER FURNISHEDDEVICES AND EQUIPMENT. SUCHINCLUDES, BUT ARE NOT LIMITED TOSPECIALTY LIGHT FIXTURES, CEILINGMOUNTED PROJECTORS, TV MONITORS,PROJECTOR SCREENS, AUDIOEQUIPMENT, CASEWORK, ETC.ALL WORK SHALL COMPLY WITH ALLAPPLICABLE CODES AND STATUES,INCLUDING THE AMERICAN WITHDISABILITIES ACT AND INTERNATIONALBUILDING CODE.
11.
THE EXACT LOCATION OF ALLELECTRICAL DEVICES EXPOSED TO VIEWOR SERVING GOVERNMENT FURNISHEDEQUIPMENT (INCLUDING BUT NOTLIMITED TO RECEPTACLES, LIGHTSWITCHES, FLOOR BOXES, TELEPHONE /DATA BOXES, WALL SCONCES, ALARMSAND THERMOSTATS) SHALL BEPHYSICALLY MARKED ON THE FLOOR,WALL AND CEILING AND APPROVED BYTHE GOVERNMENT REPRESENTATIVEPRIOR TO INSTALLATION.ANY DAMAGE TO EXTERIOR WALLSSHALL BE REPAIRED AND FINISHED TOMATCH ADJACENT SURFACES, UNLESSNOTED OTHERWISE.
12.
13.
GENERAL NOTESINDICATES EXISTING WALLSTO REMAIN
5. SEE SHEET A0.1 FOR GENERALINFORMATION AND ABBREVIATIONS
ARCHITECTURALLY THE FINISHED FLOORELEVATION 0 FEET 0 INCHES EQUALS22.66 FEET CIVIL
14.
15. REFER TO SHEET ID2.0FOR SIGNAGES-#
2-HR FIRE-
KEYNOTESDIMENSION IS FROM FACE OF EXISTING MASONRYWALL
DIMENSION IS CLEAR OPENING FROM FACE OFFINISHES.
ALIGN FRAMING/FINISHED WALL WITH ADJACENTFRAMING/FINISHED WALL AT EXISTING MASONRYWALL.
PROVIDE STUD INFILL @ 16" [406 MM] O.C. MAX ATEXISTING OPENINGS.
DIMENSION CLEAR BETWEEN FACE OF CABINETSBELOW COUNTER OR BETWEEN FACE OFCABINETS TO FINISHED WALL.
1
2
3
4
5
ELEVATOR: VERIFY CLEAR DIMENSIONS ANDCLEARANCES WITH ELEVATOR MANUFACTURER.
FIELD VERIFY ROUGH OPENING DIMENSION FORREPLACEMENT OF EXISTING WINDOW SYSTEMS.
PROVIDE BRICK INFILL FINISH EXTERIOR WALL TOMATCH ADJACENT. INSTALL SALVAGED BRICKWHERE APPLICABLE.
ALL WINDOW GLASS IN ALL TOILET ROOMS:PROVIDE TRANSLUCENT OBSCURE WINDOW FILM(INTERIOR SIDE) FOR PRIVACY. SUBMIT SAMPLE FORSELECTION
6
7
8
9
THIS DOOR: PROVIDE METAL SIGN WITH REBACKGROUND AND WHITE HELVETICA BOLDLETTERS "FIRE SRPINKLER ROOM". SUBMITT SHOPDRAWINGS FOR REVIEW AND APPROVAL.
THIS DOOR: MODIFY FRAME AND PROVIDECONCEALED POWER AND CONDUIT/WIRE ASREQUIRED FOR COMPLETE INSTALLATION FORDOOR MONITORING CAMERA AND DOORMAGNETIC LOCK/STRIKE FROM DOOR TOACTIVATION SWITCH AND MONITORING SYSTEM(C.F.C.I.) LOCATED IN ADMINISTRATIVE OFFICE 204.LOCATION OF SWITCH AND MONITOR TO BEDETERMINED BY GOVERNMENT REPRESENTATIVE.REFER ALSO TO ELECTRICDAL DRAWINGS ANDHARDWARE SCHEDULE.
10
11 ARCHITECTURAL GROUP, INC.
A
B
C
1 2 3 4
D
E
F
G
H
5 6 7 8 9 10
J
K
L
M
11 12 13 14
PROJECT TITLE AND OWNERS NAME
CONSULTANTS
SEAL AND SIGNATURE
REVISIONS
DRAWN BY
CHECKED BY
JOB NUMBER
DATE
DRAWING TITLE
DRAWING NUMBER
SHEET OF
FL LIC. # AA0002264
5032 GODDARD AVENUEORLANDO, FLORIDA 32804(407) [email protected]
COPYRIGHT © 2015 MRI ARCHITECTURAL GROUP INC.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
15
15
06/22/15
PETER M. IKEGAMIAR0013065
8/9/
2015
12:
39:5
0 P
MC
:\Use
rs\P
Ikeg
ami\D
ocum
ents
\A4
-201
4 M
RI -
Pro
posa
ls\1
411
- Tam
pa A
rmor
y\D
MS
TAM
PA-
RED
BR
ICK
BU
ILD
ING
BID
AN
D R
ESPO
NS
E TO
BLD
G.rv
t
A1.1
PMI
JLR
FDMA PROJECT NO.215004
FIRST FLOOR PLAN
"RED BRICK"BUILDING ANNEXTAMPA NATIONALGUARD ARMORY
DEPARTMENT OFMILITARY AFFAIRSST AUGUSTINE, FLORIDA
PERMIT ANDCONSTRUCT
1/4" = 1'-0"A1.1
A1 RENOVATED FIRST FLOOR12'8'4'2'0
1/4" = 1'-0"
N
FF
FF
F
F
F
F
NG
F
F
F
NG
NG F
F
F
F
F
1 RESPONSE TO
BLDG DEPT
07-27-15
2 RESPONSE TO
FIRE MARSHAL
08-07-15
4' - 1 1/2" 4' - 0" 6' - 7 1/4" 4' - 0" 5' - 3 1/8" 4' - 0" 4' - 5" 4' - 0" 4' - 4 1/2" 4' - 0" 5' - 3 7/8" 4' - 0" 4' - 7 3/4" 4' - 0" 5' - 3 1/2" 4' - 0" 4' - 5 1/4" 4' - 0" 4' - 5 1/4" 4' - 0" 4' - 1 1/2" 4' - 0" 3' - 9 7/8"
1' - 1
1 3/4"
4' - 0
"2'
- 11 1
/2"4'
- 0"
FIRE STAIRS200
AGR RRNCOOFFICE
201
ADMINISTRATIONOFFICE
204
READINESSOFFICE
205
HVAC208
23' - 10"
COMMANDMEETING
213
CDR OFFICE216
1SG OFFICE214
7' - 6" 2' - 0" 7' - 6" 4' - 9"
PLATOON AWORK ROOM
2063'-8" X 8'-0"CONFERENCETABLE
COPY /MAIL207
M TLT211
W TLT212
FILES / STO
5' - 0"
PLATOON BWORK ROOM
209
XO OFFICE215
KEY
SAFE
S
2 HR FIRERATED GLAZING
2-HR FIRE RATEDGLAZING
LOBBY202
18'-4".
15' -
6 7/8"
20' -
6"
5' - 0 1/4"
STOREFRONT WINDOW(NO FIRE RATING)
11' - 4" 13' - 11" 18' - 4"
MAINTENANCEOFFICE
203
6' - 11"
8' - 4
"
3' - 6
"1'
- 6"3'
- 6"
1' - 6
"2'
- 0"5' - 0"
3' - 1
1/2"
4' - 0
"2'
- 11 1
/2"4'
- 0"
4' - 3
1/4"
4' - 0
"8'
- 10 1
/8"4'
- 0"
4' - 5
1/2"
4' - 0
"
7' - 4 7/8" 4' - 0" 2' - 3 5/8" 4' - 0" 7' - 3 1/2" 4' - 0" 10' - 0 3/4" 4' - 0" 8' - 0 5/8" 4' - 0" 2' - 9 7/8" 4' - 0" 7' - 10 1/2" 4' - 0" 9' - 6" 4' - 0" 5' - 8 3/4" 4' - 0" 3' - 9 7/8"
EXISTING PORCH STANDING SEAM ROOF TO REMAIN(PROTECT FROM DAMAGE)
ADD-ALT #4: NEW GUTTERS AND DOWNSPOUTS AND FLASHINGS GUTTERADD-ALT #4: NEW GUTTERS AND DOWNSPOUTS AND FLASHINGS TO GUTTER
12' - 6" 11' - 4"
15' -
4"
15' -
4"
12' -
0"4'
- 0"
7' - 1
0 1/2"
12' -
5"
10
6
6
6
6
6
6
6
6
6
6
6B
6B
6B
6C
6C
6
1
1 13 1
1
1
6
6
6
66
6
6
10B
10B
10B
10B
101010 10
10
10 1010
10 10 10
10
10
1010
215
200B
204B205
213
211
212
216
214
204A
200A
208
ALIG
N W
/ ELE
V FR
AMIN
G
9'-10
"+
NEW HI-LO ADA DF 30X4
8AD
ACL
R
30X48ADACLR
30X48ADACLR
6B
6
6B
STO210 21
0
6' - 2"
W5
W5
W5 W5 W5 W5 W5 W5 W5 W5 W5 W5 W5
W5
W5W5W5W5W5W5W5
W8
HG
HG
HG
HG
HG
HG HG
HG
F
F
F
FF
F
OPERABLEWINDOW
OPERABLEWINDOW
203
201
1' - 4
"
8' - 0
"
2-HR FIRE RATEDGLAZING IN DOOR
2-HR FIRE RATEDGLAZING IN DOOR
W5 W5
14'-1
0"+/
-
OF W
ALL T
O FA
CE O
F W
A LL
9'-0"
CLE
AR F
ROM
FACE
FACE OF FINISHED WALL BELOW
42" HIGH WALLWITH SOLIDSURFACE CAP
42" WALL WITH SOLIDSURFACE CAP
NEW FLOOR STRUCTUREINFILL (REFER TOSTRUCTURAL DRAWINGS)
NEW FLOOR STRUCTUREINFILL (REFER TOSTRUCTURAL DRAWINGS)
S-1
S-1S-1S-1
S-3
S-1
S-2
S-1
S-1
S-4
S-4
S-6
S-1
S-1
7 7 7 7 7 7 7 7 7 7 7
7
7
7
A8.1H8
A1
A4.3
A10
A4.1
A3.1
A1
A3.1A1
A3.1 J1
A3.1
E1
W6
W7
OPERABLEWINDOW
7
OPERABLEWINDOW
7
OPERABLEWINDOW
7
OPERABLEWINDOW
7
OPERABLEWINDOW
7
FIXEDWINDOW
7
FIXEDWINDOW
7
OPERABLEWINDOW
7
OPERABLEWINDOW
W5
OPERABLEWINDOW
7
W5
OPERABLEWINDOW
7
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
OPERABLEWINDOW
W5
OPERABLEWINDOW
7
OPERABLEWINDOW
7
W5
OPERABLEWINDOW
7
6
6
1' - 5"
HANDRAILS AND GUARDRAILS,REFER TO SHEET A5.1
10
(2)-KEY SAFE EYE HOOK ANCHORAGE. REFER TOSTRUCTURAL DRAWINGS, DETAIL 4/SHEET A2.5.COORDINATE EXACT LOCATION WITH GOVERNMENT.
RECYCLING10 SF
44".
44"
1' - 11" 1' - 0"
44".
1
2
1.
2.
3.
4.
6.
7.
8.
9.
10.
PARTITION TYPE (SEE A7.1)XX
STOREFRONT GLAZING TYPE(SEE SHEET A6.1)
XX
DOOR NUMBER (SEE SHEET A6.1)
SEE SHEET ID1.0 FOR ROOM FINISHSCHEDULES.
XXX
ALL DIMENSIONS TO FACE OF CONCRETEOR MASONRY AND TO FACE OF INTERIORMETAL STUD WALLS OR CENTER LINE OFCOLUMN UNLESS NOTED OTHERWISE.
1-HR FIRE-RATED WALL CONSTRUCTION
REFER TO LIFE SAFETY PLANS LS1.1 ANDLS1.2 FOR FIRE EXTINGUISHER CABINETAND WALL MOUNTED FIRE EXTINGUISHERS.
GENERAL CONSTRUCTION CONTRACTORSHALL PROVIDE ALL BLOCKING /SUPPORTS WITHIN WALLS AND ABOVECEILINGS FOR OWNER FURNISHEDFINISHES / MATERIALS, DEVICES ANDEQUIPMENT. ALL BLOCKING SHALL BE OFNON-COMBUSTIBLE MATERIAL. FIRETREATED LUMBER MAY BE USED IFPERMITTED BY BUILDING CODE ANDAGENCY HAVING JURISDICTION. ALLSUPPORTS SHALL BE FIELD LOCATED ANDAPPROVED BY THE GOVERNMENTREPRESENTATIVE PRIOR TO FINALINSTALLATION.GENERAL CONSTRUCTION CONTRACTORSHALL COORDINATE ALL TRADES ANDSHALL PROVIDE ELECTRICAL,MECHANICAL, PLUMBING SERVICES ANDHOOKUPS TO OWNER FURNISHEDDEVICES AND EQUIPMENT. SUCHINCLUDES, BUT ARE NOT LIMITED TOSPECIALTY LIGHT FIXTURES, CEILINGMOUNTED PROJECTORS, TV MONITORS,PROJECTOR SCREENS, AUDIOEQUIPMENT, CASEWORK, ETC.ALL WORK SHALL COMPLY WITH ALLAPPLICABLE CODES AND STATUES,INCLUDING THE AMERICAN WITHDISABILITIES ACT AND INTERNATIONALBUILDING CODE.
11.
THE EXACT LOCATION OF ALLELECTRICAL DEVICES EXPOSED TO VIEWOR SERVING GOVERNMENT FURNISHEDEQUIPMENT (INCLUDING BUT NOTLIMITED TO RECEPTACLES, LIGHTSWITCHES, FLOOR BOXES, TELEPHONE /DATA BOXES, WALL SCONCES, ALARMSAND THERMOSTATS) SHALL BEPHYSICALLY MARKED ON THE FLOOR,WALL AND CEILING AND APPROVED BYTHE GOVERNMENT REPRESENTATIVEPRIOR TO INSTALLATION.ANY DAMAGE TO EXTERIOR WALLSSHALL BE REPAIRED AND FINISHED TOMATCH ADJACENT SURFACES, UNLESSNOTED OTHERWISE.
12.
13.
GENERAL NOTESINDICATES EXISTING WALLSTO REMAIN
5. SEE SHEET A0.1 FOR GENERALINFORMATION AND ABBREVIATIONS
ARCHITECTURALLY THE FINISHED FLOORELEVATION 0 FEET 0 INCHES EQUALS22.66 FEET CIVIL
14.
15. REFER TO SHEET ID2.0FOR SIGNAGES-#
2-HR FIRE-
KEYNOTESDIMENSION IS FROM FACE OF EXISTING MASONRYWALL
DIMENSION IS CLEAR OPENING FROM FACE OFFINISHES.
ALIGN FRAMING/FINISHED WALL WITH ADJACENTFRAMING/FINISHED WALL AT EXISTING MASONRYWALL.
PROVIDE STUD INFILL @ 16" [406 MM] O.C. MAX ATEXISTING OPENINGS.
DIMENSION CLEAR BETWEEN FACE OF CABINETSBELOW COUNTER OR BETWEEN FACE OFCABINETS TO FINISHED WALL.
1
2
3
4
5
ELEVATOR: VERIFY CLEAR DIMENSIONS ANDCLEARANCES WITH ELEVATOR MANUFACTURER.
FIELD VERIFY ROUGH OPENING DIMENSION FORREPLACEMENT OF EXISTING WINDOW SYSTEMS.
PROVIDE BRICK INFILL FINISH EXTERIOR WALL TOMATCH ADJACENT. INSTALL SALVAGED BRICKWHERE APPLICABLE.
ALL WINDOW GLASS IN ALL TOILET ROOMS:PROVIDE TRANSLUCENT OBSCURE WINDOW FILM(INTERIOR SIDE) FOR PRIVACY. SUBMIT SAMPLE FORSELECTION
6
7
8
9
THIS DOOR: PROVIDE METAL SIGN WITH REBACKGROUND AND WHITE HELVETICA BOLDLETTERS "FIRE SRPINKLER ROOM". SUBMITT SHOPDRAWINGS FOR REVIEW AND APPROVAL.
THIS DOOR: MODIFY FRAME AND PROVIDECONCEALED POWER AND CONDUIT/WIRE ASREQUIRED FOR COMPLETE INSTALLATION FORDOOR MONITORING CAMERA AND DOORMAGNETIC LOCK/STRIKE FROM DOOR TOACTIVATION SWITCH AND MONITORING SYSTEM(C.F.C.I.) LOCATED IN ADMINISTRATIVE OFFICE 204.LOCATION OF SWITCH AND MONITOR TO BEDETERMINED BY GOVERNMENT REPRESENTATIVE.REFER ALSO TO ELECTRICDAL DRAWINGS ANDHARDWARE SCHEDULE.
10
11 ARCHITECTURAL GROUP, INC.
A
B
C
1 2 3 4
D
E
F
G
H
5 6 7 8 9 10
J
K
L
M
11 12 13 14
PROJECT TITLE AND OWNERS NAME
CONSULTANTS
SEAL AND SIGNATURE
REVISIONS
DRAWN BY
CHECKED BY
JOB NUMBER
DATE
DRAWING TITLE
DRAWING NUMBER
SHEET OF
FL LIC. # AA0002264
5032 GODDARD AVENUEORLANDO, FLORIDA 32804(407) [email protected]
COPYRIGHT © 2015 MRI ARCHITECTURAL GROUP INC.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
15
15
06/22/15
PETER M. IKEGAMIAR0013065
8/9/
2015
12:
39:5
2 P
MC
:\Use
rs\P
Ikeg
ami\D
ocum
ents
\A4
-201
4 M
RI -
Pro
posa
ls\1
411
- Tam
pa A
rmor
y\D
MS
TAM
PA-
RED
BR
ICK
BU
ILD
ING
BID
AN
D R
ESPO
NS
E TO
BLD
G.rv
t
A1.2
PMI
JLR
FDMA PROJECT NO.215004
SECOND FLOOR PLAN
"RED BRICK"BUILDING ANNEXTAMPA NATIONALGUARD ARMORY
DEPARTMENT OFMILITARY AFFAIRSST AUGUSTINE, FLORIDA
PERMIT ANDCONSTRUCT
N12'8'4'2'0
1/4" = 1'-0" 1/4" = 1'-0"A1.2
A1 RENOVATED SECOND FLOOR
1 RESPONSE TO
BLDG DEPT
07-27-15
2 RESPONSE TO
FIRE MARSHAL
08-07-15
ON ALL WALLS WITHIN THIS ROOM:PROVIDE AND INSTALL MARLITE WOODPANEL SYSTEM (OR EQUAL) WITH 2'-0"WIDE X 2'-0" HIGH O.C. PANELS. HEIGHTTO BE 4'-0" FROM FINISHED FLOOR TO 4'-0" A.F.F. WITH 1/4" SATIN STAINLESS STEELREVEALS ALL SIDES OF PANELS. PROVIDEDECORATIVE 1-1/2" WOOD CAP WITHEASED EDGES AT TOP. AT WINDOWOPENINGS: SYSTEM TO TURN ANDTERMINATE AT WINDOW FRAMESSTAINCOLOR TO MATCH STAINED DOORS.SUBMIT SAMPLES FOR APPROVAL