Page 1: Remote monitor tool Operating Manual

MITSUBISHI CNC C70 / C64 Series Remote monitor tool Operating Manual

BNP-B2324D (ENG)

Page 2: Remote monitor tool Operating Manual

1 Outline ......................................................................................................................... 5

2 System configuration ................................................................................................... 5

2.1 Operation environment ......................................................................................................5

2.2 Connection configuration ...................................................................................................5

3 Installation of Remote monitor tool ............................................................................ 6

4 Uninstallation of Remote monitor tool........................................................................ 8

5 Upgrading of Remote monitor tool .............................................................................. 8

6 Start and termination.................................................................................................. 9

6.1 Starting remote monitor tool..............................................................................................9

6.2 Terminating Remote monitor tool......................................................................................9

7 Screen configuration .................................................................................................. 10

7.1 Title bar.............................................................................................................................10

7.2 Menu bar...........................................................................................................................11

7.3 Tool bar .............................................................................................................................11

7.4 NC information part .........................................................................................................12

7.5 Status bar..........................................................................................................................13

7.6 File transfer dialog box ....................................................................................................14

8 Operation details ....................................................................................................... 15

8.1 Connect with Machine tool (NC)......................................................................................15 8.1.1 Connection with automatically searched NC............................................................................15 8.1.2 Another search for connectable NCs..........................................................................................17 8.1.3 Connection with the NC whose IP address has been manually input ....................................17

8.2 Operate NC screen............................................................................................................17

8.3 Send and receive a parameter file. ..................................................................................18 8.3.1 Receiving parameter file.............................................................................................................18 8.3.2 Sending parameter file ...............................................................................................................19

8.4 Send and receive the program..........................................................................................20 8.4.1 Receiving program file................................................................................................................20 8.4.2 Sending program file ..................................................................................................................21

8.5 Receiving a maintenance file. ..........................................................................................23 8.5.1 Receiving Maintenance file (SRAM.BIN)..................................................................................23 8.5.2 Receiving Maintenance file (NCSAMP.CSV)............................................................................23

8.6 Send/Receive/Delete/Compare C language module .........................................................24 8.6.1 Sending C language module.......................................................................................................24 8.6.2 Receiving C language module ....................................................................................................24 8.6.3 Deleting C language module ......................................................................................................25 8.6.4 Comparing C language module..................................................................................................25

8.7 Send and receive the other file.........................................................................................26 8.7.1 Receiving the other file...............................................................................................................26 8.7.2 Sending the other file .................................................................................................................26

8.8 Display Remote monitor tool's manual............................................................................28

8.9 Confirm the remote monitor tool version ........................................................................28

9 Setting NC Parameters ............................................................................................. 29

Page 3: Remote monitor tool Operating Manual

10 Appendix ................................................................................................................. 30

10.1 Error message and its remedy......................................................................................30

10.2 How to cancel Windows fire wall block ........................................................................32

10.3 Obtaining the authority to operate the keys................................................................34

10.4 Hosts files ......................................................................................................................35

10.5 Enabling to send a parameter file and a machining program file ..............................36 MELDAS is a registered trademark of Mitsubishi Electric Corporation. Microsoft and Windows are the registered trademarks of Microsoft Corporation. Other brands and product names throughout this manual are trademarks or registered trademarks of their respective holders The specifications described in this document are subject to change without notice. Copyright(C) 2001(2012) MITSUBISHI ELECTRIC CORPORATION All Rights Reserved.

4

Page 4: Remote monitor tool Operating Manual

1 Outline

This manual explains how to set and use Remote monitor tool. Remote monitor tool is the software that enables comprehension of the conditions of remotely placed numerical controllers by using intranet in factories. Remote monitor tool has the following functions. - To remotely monitor NC screens by using intranet - To input and output parameters / machining programs

2 System configuration

2.1 Operation environment

Remote monitor tool works in the following environment.

Items Details OS Microsoft Windows 2000(SP3 or higher)/ XP / Vista / 7

Processor Conform to the environment recommended for Windows. RAM Conform to the environment recommended for Windows.

Hard disk space 50MB or more (excluding the capacity required for OS) Interface 10/100M Ethernet Monitor 800x600 or higher resolution, 256 colors or more

2.2 Connection configuration Remote monitor tool functions under the following configuration. - The NCs connected via Ethernet can be monitored. - Up to 8 monitors can be simultaneously connected for one NC.

Remote monitor tool

CNC CPU

Ethernet

GOT1000 Series

CNC monitor

Items Details Connectable NC C6/C64/C64T (Version C or later), C70

Number of simultaneously connectable monitors

Up to 8 NC screens per NC can be connected and monitored by Remote monitor tool (including a GOT's CNC monitor screen, C6/C64 dedicated display and WindowsCE display)

5

Page 5: Remote monitor tool Operating Manual

3 Installation of Remote monitor tool

Install Remote monitor tool in the following steps (log on as an administrator). 1) Start the installer.

Choose the language to use during installation and click the [Next] button.

2) The screen of "Welcome!" is displayed. Follow the instruction on the screen and click the [Next]

button.

6

Page 6: Remote monitor tool Operating Manual

3) Next, the "SOFTWARE LICENSE AGREEMENT" screen is displayed. Thoroughly read the contents of "SOFTWARE LICENSE AGREEMENT". If you agree, click [Yes]. Or click [No] to stop installation. If you click [RETURN], you will return to the "Welcome!" screen.

4) When the [Customer Information] window pops up, enter the user name, company name and serial number, and click on [Next].

5) Next, the "Choose Destination Location" screen is displayed. On this window, select the directory

to install Remote monitor tool to. When you wish to install to another directory, click [Browse] and choose the directory. After selecting, click [Next] to start installing Remote monitor tool.

7

Page 7: Remote monitor tool Operating Manual

* If "Program Compatibility Assistant" pops up in Windows Vista or Windows 7, click on "This

program installed correctly".

4 Uninstallation of Remote monitor tool Uninstall Remote monitor tool in the following steps (log on as an administrator). 1) Terminate Remote monitor tool. 2) Choose [Start] -> [Setting] -> [Control Panel]. 3) Choose and double-click [Add/Remove Programs] in the Control Panel. 4) Choose [Remote monitor tool]. 5) After making selection, click [Add/Remove]. 6) Follow the instruction on the screen to proceed with uninstallation.

* This is the uninstallation procedure for Windows XP. Some item names in uninstallation may differ from Windows 2000/Vista/7.

5 Upgrading of Remote monitor tool Upgrade Remote monitor tool in the following steps (log on as an administrator).

If the version of Remote monitor tool installed is C1 or before:

1) Follow the steps described in Chapter 4 to do uninstallation. 2) Follow the steps described in Chapter 3 to do installation. * If you attempt to upgrade it to C2 or newer without uninstallation, the upgrading will be interrupted by the below error dialog. You can resume upgrading by following the steps below after the error dialog interrupted the installation.

If the version of Remote monitor tool installed is C2 or newer:

1) Follow the steps described in Chapter 3 to do installation.

8

Page 8: Remote monitor tool Operating Manual

6 Start and termination

This chapter explains how to start and terminate Remote monitor tool. 6.1 Starting remote monitor tool

Execute either of the below mentioned operations. - Double click the program icon of Remote monitor tool - Select the short-cut menu for Remote monitor tool from the [Start] menu. Remote monitor tool enables monitoring of more than one NC at a time by activating more than one tool as shown below.

6.2 Terminating Remote monitor tool To terminate Remote monitor tool, select [Exit] from the [File] menu. Clicking the [X] button on the title bar also terminates the tool.

9

Page 9: Remote monitor tool Operating Manual

7 Screen configuration

The window of Remote monitor tool consists of a "title bar", "menu bar", "tool bar", "NC information display" and "status bar". When transferring a file, the file transfer dialog box appears.

Title bar Menu bar

NC information

Status bar

Tool bar

7.1 Title bar The following items are displayed on the title bar.

(4) Exit (1) Tool name

(2) IP address of the connected NC

(3) Iconified tool

(1) Tool name This shows the name "CNC Remote Monitor".

(2) IP address of the connected NC

This shows the IP address of the connected NC.

(3) Iconified tool Click this button to minimize the window of Remote monitor tool to the size of an icon and to be contained in the task bar.

(4) Exit Click this button to exit from Remote monitor tool.

10

Page 10: Remote monitor tool Operating Manual

7.2 Menu bar

Each function including connection destination designation can be selected from the "menu bar".

1) File

Various functions of this tool can be activated using the [File] menus.

Connect This opens the dialog box for specifying the connection destination. Connection with the NC specified here will be made.

Translate This is used to send and receive the parameter, machining program, maintenance data and C language module of the connected NC. When each of the menu items is selected, the file transfer tool will start up.

Online This switches the communication state with NC between online and offline.

Exit This exits from Remote monitor tool.

2) Help

The manual and version information of this tool can be displayed using the [Help] menus.

Show Manual This shows the manual of Remote monitor tool.

About Remote monitor tool This shows the software version of Remote monitor tool.

7.3 Tool bar Various functions can be executed using the toolbar items. For details of the functions possible to be activated from the "tool bar", see the instruction manuals of each function.

Send/Receive Program in Text Format

Send/Receive Parameter in Text Format

START/STOP

Receive NC sampling data

CONNECT

11

Page 11: Remote monitor tool Operating Manual

7.4 NC information part

The information of NC that is being monitored is displayed on the "NC information part". Click each button or key to operate the NC. It is also possible to input directly using a personal computer keyboard.

Relation between the mouse click buttons and keyboard keys

Function selection

NC information

Menu

Menu 1 Menu 2 Menu 3 Menu 4 Operation

Menu /

Keyboard

Buttons to be clicked. Keyboard keys Menu 1 F1 Menu 2 F2 Menu 3 F3 Menu 4 F4 Menu / Operation F5 Position display F6 Alarm diagnosis F7 Tool offset / Param. F8 Program F9 Back, Next PageUp, PageDown

C+B / CAN Home / Shift+Home Adjust Insert Delete Delete, Back space EOB ; Shift Shift INPUT Enter 0 ~ 9 0 ~ 9 !,#,$,(,),=,-,+,[,],*,/ !,#,$,(,),=,-,+,[,],*,/ ,. ,. Space SPACE

, Shift+Tab, Tab, , ,, , , , ,

12

Page 12: Remote monitor tool Operating Manual

7.5 Status bar

The status of Remote monitor tool including communication status is displayed on the "status bar".

"Items displayed on Status bar"

READY

COMMUNICATION ERROR / DISPLAY INVALID

ONLINE/OFFLINE

No Display Meaning

1 ONLINE

This indicates the status that Remote monitor tool is communicating with the designated NC. To change the status to online, click the [CONNECT] button on the toolbar or select [Connect] from the menu. Or press the [START/STOP] button or select [Online] from the menu.

2 OFFLINE

This indicates the status that Remote Monitor Tool is not communicating with the designated NC. Select the [START / STOP] button on the tool bar or select [Online] from the menu to change the status to the online mode.

3 COMMUNICATION ERROR

This indicates that the communication error between Remote monitor tool and the connected NC has occurred.

4 DISPLAY INVALID

This indicates the status that "NC information display" is disabled because the connected NC's parameter #21034 is set to "1". To display the NC screen, set the connected NC's parameter #21034 to "0".

5 READY This indicates that the connected NC's operation is ready.

13

Page 13: Remote monitor tool Operating Manual

7.6 File transfer dialog box Select [File (F)] -> [Translate] -> [Parameter] -> [Text] etc. from the menu bar to transfer a file. And then, the file transfer dialog box pops up, which enables inputting/outputting of various files between the NC and personal computer. For how to input and output files, refer to the sections from 8.3 to 8.7.

Receive a file (from NC to personal computer)

Send a file (from personal computer to NC)

Compare files (between NC and personal computer) * For a C language module only

Delete a file (in NC) * For a C language module only

Dialog title (varies according to the transfer type)

* Even when more than one Remote monitor tool is run, only one file transfer dialog appears. * When Remote monitor tool is terminated with the file transfer dialog displayed, the dialog box

is not closed and the input/output operation is enabled.

14

Page 14: Remote monitor tool Operating Manual

8 Operation details

8.1 Connect with Machine tool (NC)

8.1.1 Connection with automatically searched NC 1) Select [File] -> [Connect] from the menu bar to open the dialog for specifying the connection

destination.

* When [Connect] is selected for Windows Vista or Windows7, the "Windows Security Alert" dialog pops up to ask if you wish to block receiving. In this case, select [Unblock] from this dialog box. If you select [Keep blocking] or ignore this warning, automatic search cannot be properly performed (Note however that it is possible to connect with the NC by manually inputting the IP address). To enable automatic search, refer to " 10.2 How to cancel Windows fire wall block" and cancel the Windows Firewall block.

2) Connectable NCs are automatically searched and are listed in a list box. Select the IP

address of the NC to connect from the list and click the [Connect] button.

When the connection is properly made, the NC information part is displayed. If any communication error occurs, "COMMUNICATION ERROR" is displayed on the status bar.

* Automatic search is available in C70 only but is not available in C6, C64 or C64T. Input the IP address manually when the NC is C6, C64 or C64T. For how to input the address manually, refer to " 8.1.3 Connection with the NC whose IP address has been manually input".

List box

IP address of the connected NC

15

Page 15: Remote monitor tool Operating Manual

* Up to 512 lines can be displayed in the connection list. If more than 512 NCs are

* When a list of connection destinations is set to the Hosts file, the connection destination

".

* When automatic search is frequently repeated, it takes longer to display the list, thus the

Connection display

This list box shows a list of automatically searched NC information and the connection

are not registered in the Hosts file is

he NC information such as "Connection status", "IP address", "Connection destination" and

.

Connection status An asterisk mark "*" is added to the NCs found during auto search,

IP address his displays the IP address of the connected NC.

Connection his displays the connection destination names, etc. that have been

Name of the t

his displays the unit name (#1135 unt_nm) that has been set to

Format>

ss] Connection destination name (Name of the connected unit)

isplay example AB) : An automatically searched NC, which is not registered

connectable, some will not be displayed.

NC names, etc. can be displayed in the IP address list. For how to create the Hosts file, refer to " 10.4 Hosts files

list of connection destinations may be blank. This phenomenon occurs when communication with NCs is busy. In this case, wait for about a minute, and perform search again.

destinations that have been registered in the Hosts file. At the top of the list, the information of the NCs that displayed. The information of the NCs that are registered in the Hosts file follows next. T"Name of the connected unit" is displayed. The details of each item are described below

meaning that the NC is connectable. T

destination Tregistered in the Hosts file. This area is left blank when the NC is not registered in the Hosts file.

connected uniTthe automatically searched NC. This display is right aligned. If the unit name is not set to the NC, a four-character space is displayed.

<* [IP Addre D

*[192.168.1.1]( in the Hosts file.

*[192.168.1.4]( XYZ) [192.168.1.3]abcdefg( ) n NC that is registered in the Hosts file but is not : A

connectable. *[192.168.1.2]ABCDEFG(ABCD) egistered in the Host file and is : An NC that is r

connectable. If the same IP address is described more than once in the Hosts file, the same IP address is

*displayed on the connection list by the same number. However, the asterisk mark "*" is displayed only at the first address.

16

Page 16: Remote monitor tool Operating Manual

8.1.2 Another search for connectable NCs 1) Press the [Search] button while the connection designation dialog is displayed.

The connectable NCs are searched again and a list in the list box is updated. 8.1.3 Connection with the NC whose IP address has been manually input 1) Select [File] -> [Connect] from the menu bar to open the dialog for specifying the connection

destination. 2) Click on the IP address field and enter the IP address of the connected NC. 3) Press the [Connect] button.

8.2 Operate NC screen

Various operations can be performed on the NC screen, such as monitoring position information, etc., operation search, tool compensation setting, program editing, alarm diagnosis and NC parameter setting. For details of the NC screen operations, refer to the "CNC monitor screen" section in each NC's instruction manual.

17

Page 17: Remote monitor tool Operating Manual

8.3 Send and receive a parameter file.

8.3.1 Receiving parameter file 1) Select [File] -> [Translate] -> [Parameter] -> [Text] from the "menu bar".

Or select [Binary] and make the "Parameter-Text" dialog box or the "Parameter-Binary" dialog box display.

2) Select "ALL.PRM" (in text format) from the list or select "PARAMET.BIN" (in binary format). 3) Press the [Receive] button.

4) When the "Save As" dialog pops up, specify the directory to save the file to and the file name,

and then press the [Save] button.

5) When transmitting has succeeded, the "Succeeded." dialog box appears.

Specify the parameter file to receive

Specify the folder

Specify the file name

18

Page 18: Remote monitor tool Operating Manual

8.3.2 Sending parameter file

To send parameter file, change the setting of "ReC64Monitor.ini" to enable sending. For how to set "ReC64Monitor.ini", refer to " 10.5 Enabling to send a parameter file and a machining program file".

1) Select [File] -> [Translate] -> [Parameter] -> [Text] from the "menu bar".

Or, select [Binary] and make the "Parameter-Text" dialog box or the "Parameter-Binary" dialog box display.

2) Press the [Send] button.

3) When the "Open" dialog pops up, select the parameter file to send to the NC and press the

[Open] button.

4) When transmitting has succeeded, the "Succeeded." dialog box appears.

Specify the parameter file to send

19

Page 19: Remote monitor tool Operating Manual

8.4 Send and receive the program.

8.4.1 Receiving program file 1) Select [File] -> [Translate] -> [Program] -> [Text] from the "menu bar".

Or, select [Binary] and make the "Program-Text" dialog box or the "Program-Binary" dialog box display.

* The program files in "Binary" format can be handled in C6, C64 and C64T only.

2) Select "*.PRG" (Text) or "FILESYS.BIN" (Binary) from the list.

* If machining program files are in text format, it is possible to select more than one file arbitrarily.

3) Press the [Receive] button. 4) When the "Save As" dialog box pops up, specify the folder to save the file to and the file

name, and then press the [Save] button. 5) When transmitting has succeeded, the "Succeeded." dialog box appears.

Specify the parameter file to receive

When receiving programs after selecting more than one program When more than one program is selected and received, all the selected programs are combined into the "ALL.PRG" file and received. The selected programs are stored in "ALL.PRG" in the order of the program number. This file can be stored again in the NC by transmitting.

20

Page 20: Remote monitor tool Operating Manual

Type of receivable program

When receiving a program in a text format, it is possible to change the type of program to receive by changing the directory selection shown at the top of the file send/receive dialog box.

Directory Program file \PRG\USER\ User program \PRG\MDI\ MDI program

8.4.2 Sending program file

To send program files, change the setting of "ReC64Monitor.ini" to enable sending. For how to set "ReC64Monitor.ini", refer to " 10.5 Enabling to send a parameter file and a machining program file".

1) Select [File] -> [Translate] -> [Program] -> [Text] from the "menu bar".

Or, select [Binary] and make the "Program-Text" dialog box or the "Program-Binary" dialog box display.

* The program files in "Binary" format can be handled in C6, C64 and C64T only.

2) Press the [Send] button. 3) When the "Open" dialog pops up, select the program file to send to the NC and press the

[Open] button. 4) When transmitting has succeeded, the "Succeeded." dialog box appears. Type of transferable program When sending a program in a text format, it is possible to change the type of program to send by changing the directory selection shown at the top of the file send/receive dialog box.

Directory Program file Remarks \PRG\USER\ User program \PRG\MDI\ MDI program When an MDI program is sent, the MDI

status changes to "MDI setting completed".

21

Page 21: Remote monitor tool Operating Manual

Data protection

If the "Data protection is ON" error appears in sending a program, check the following signals and parameters ( : related -: not related)

Program sent Y31A

(Data protect key 3)#8105

EDIT LOCK B#1121 edlk_c

#1144 mdlkof

1 to 7999.PRG, 10000 to 99999999.PRG

- - -

8000 to 8999.PRG - - 9000 to 9999.PRG - MDI.PRG - - -

22

Page 22: Remote monitor tool Operating Manual

8.5 Receiving a maintenance file.

Maintenance data is used to investigate failures that occur at customers. Maintenance data has types, "SRAM.BIN" that includes all the data such as parameters and machining programs, and "NCSAMP.CSV" that is obtained using NC sampling function. 8.5.1 Receiving Maintenance file (SRAM.BIN) 1) Select [File] -> [Translate] -> [Maintenance] from the menu bar, and make "Maintenance"

dialog box display. 2) Select "SRAM.BIN" from the list. 3) Press the [Receive] button. 4) When the "Save As" dialog box pops up, specify the directory to save the file to and the file

name, and then press the [Save] button. 5) When transmitting has succeeded, the "Succeeded." dialog box appears. 8.5.2 Receiving Maintenance file (NCSAMP.CSV) 1) Select [File] -> [Translate] -> [Maintenance] from the menu bar, and make "Maintenance"

dialog box display.

* Maintenance file (NCSAMP.CSV) is available with C70 only. 2) Select "M01:\LOG\" from the box at the top of the "Maintenance" dialog.

3) Select "NCSAMP.CSV" from the list. 4) When the "Save As" dialog box pops up, specify the directory to save the file to and the file

name, and then press the [Save] button. 5) When transmitting has succeeded, the "Succeeded." dialog box appears.

23

Page 23: Remote monitor tool Operating Manual

8.6 Send/Receive/Delete/Compare C language module * Before sending, receiving, deleting or comparing the C language module, the APLC release function has to be available. * Functions regarding the C language module (send/receive/delete/compare) are available with C70 only.

8.6.1 Sending C language module To send C language module, change the setting of "ReC64Monitor.ini" to enable sending. For how to set "ReC64Monitor.ini", refer to " 10.5 Enabling to send a parameter file and a machining program file". * Only one C language module can be saved in an NC. Thus, if the module is sent again while

the C language module already exists, the existing C language module is overwritten. 1) Select [File] -> [Translate] -> [C language module] from the menu bar to open the

"Send/Receive/Delete/Compare" dialog box.

2) Press the [Send] button. 3) When the "Open" dialog pops up, select the C language module to send to the NC and press

the [Open] button. 4) When transmitting has succeeded, the "Succeeded. Will be active after reboot." dialog

appears. 5) Restart the NC. 8.6.2 Receiving C language module 1) Select [File] -> [Translate] -> [C language module] from the menu bar to open the

"Send/Receive" dialog box. 2) Select "APLC.O" from the list. 3) Press the [Receive] button. 4) When the "Save As" dialog appears, specify the folder to save the file to and the file name,

and then press the [Save] button. 5) When transmitting has succeeded, the "Succeeded." dialog box appears.

24

Page 24: Remote monitor tool Operating Manual

8.6.3 Deleting C language module 1) Select [File] -> [Translate] -> [C language module] from the menu bar to open the

"Send/Receive" dialog box. 2) Select "APLC.O" from the list. 3) Press the [Delete] button. 4) The "Delete the file?" dialog appears.

- Pressing [OK] will delete the C language module stored in the NC. - Pressing [Cancel] will not delete the C language module.

8.6.4 Comparing C language module 1) Select [File] -> [Translate] -> [C language module] from the menu bar to open the

"Send/Receive" dialog box. 2) Press the [Compare] button. 3) When the "Open" dialog pops up, select the C language module to compare with the module

stored in the NC, and then press the [Open] button. 4) When comparing has succeeded, the "Compare result: matched" dialog appears.

25

Page 25: Remote monitor tool Operating Manual

8.7 Send and receive the other file When the "Other" dialog is open, the following files can be sent and received.

Directory name File name in CNC Send ReceiveWorkpiece coordinate offset DAT WORK.OFS Tool offset DAT TOOL.OFS Common variable DAT COMMON.VAR Operation history LOG TRACE.TRC -

8.7.1 Receiving the other file 1) Select [File] -> [Translate] -> [Other] from the menu bar, and make the "Other" dialog box

display. 2) Select the directory from the box at the top of the "Other" dialog. 3) Select a file from the list. 4) Press the [Receive] button. 5) When the "Save As" dialog box pops up, specify the directory to save the file to and the file

name, and then press the [Save] button. 6) When transmitting has succeeded, the "Succeeded." dialog box appears. 8.7.2 Sending the other file 1) Select [File] -> [Translate] -> [Other] from the menu bar, and make the “Other" dialog box

display. 2) Press the [Send] button. 3) When the "Open" dialog pops up, select the file to send to the NC and press the [Open]

button. 4) When transmitting has succeeded, the "Succeeded." dialog box appears. 8.7.2.1 Name of the file to send A file can be sent under the file name in CNC with arbitrary characters added to the top or end of the file name. <File name format> *(File name in CNC)*. (File extension) (* represents arbitrary characters) [Example] - Available file name examples

WORK.OFS The same file name as in CNC. NEW_WORK01.OFS The file name in CNC with arbitrary characters added to

its top and end. - Unavailable file name examples

WORK.OFFSET The file extension has changed. WK.OFS The file name in CNC is not included.

26

Page 26: Remote monitor tool Operating Manual

8.7.2.2 Directory to send to The CNC-side directory is automatically selected according to the file name. Therefore, you do not have to specify the directory to send to on the "Other" dialog box.

27

Page 27: Remote monitor tool Operating Manual

8.8 Display Remote monitor tool's manual

1) Select [Help] -> [Show Manual] from the menu bar to open the Remote monitor tool's manual.

8.9 Confirm the remote monitor tool version Make the dialog box of version information display by selecting the menu from the menu bar in order of [Help] -> [About Remote monitoring tool …].

28

Page 28: Remote monitor tool Operating Manual

9 Setting NC Parameters

By setting Base specification parameters in NC, the key operation and the display can be restricted. Change the settings below via the NC screen.

# Item Details Setting range

Standard setting

21033 KeyCtrlLmt Restriction on the authority to operate the keys

Restrict the authority to operate the keys. 0: The keys on other display units can

operate all the screens. 1: The keys on other display units are

disabled while a program screen is displayed.

2: The keys on other display units cannot operate any screen.

0-2 0

21034 ReMonDisp Display restriction

Restrict the display on Remote monitor tool. 0: Not restrict the display on Remote monitor

tool. 1: No information about display is send to

Remote monitor tool. * Do not set with Remote monitor tool, or

nothing will be displayed immediately after the setting has been done.

* To cancel the display restriction, set this parameter to 0 by using the GOT's CNC monitor function, etc. of the other display.

0-1 0

# Item Details Setting range

Standard setting

1135 unt_nm Unit name

Set the unit name. Set the name using up to four alphanumeric characters. When "0" is set, the unit name is not displayed. * The unit name is displayed at the top of the

NC information display, thus this helps distinguish the units when multiple tools are activated. Also, the unit name is displayed after the IP address during automatic search.

Up to 4 alpha- numeric charac- ters

-

29

Page 29: Remote monitor tool Operating Manual

10 Appendix

10.1Error message and its remedy

The list below shows the details of errors that can occur while Remote monitor tool is running and their remedies.

No. Message details Remedy

1 Communication error

Communication error is occurring between Remote monitor tool and the designated NC.

Confirm the following items and retry. Confirm: - that the designated IP address is correct. - that there is no problem with a cable. - that the ping command in the designated IP address is normal. - that the communication traffic is not crowded.

2 Two or more these software cannot be started.

More than 1 dialog boxes for translating files are opened.

If more than 1 dialog boxes for translating files are opened, close them leaving only 1 dialog box.

3 This software failed in the opening of a directory.

The directory information was not acquired successfully.

Confirm the following items and retry. Confirm: - that there is no problem in the file system of the connected NC. - that no communication error is occurring.

4 This software failed in reference of a directory.

The directory information was not searched successfully.

Confirm the following items and retry. Confirm: - that there is no problem in the file system of the connected NC. - that no communication error is occurring.

5 This string is a string reserved by the system.

”COM1~COM9, LPT1~LPT9, AUX, CON, PRN, NUL, CLOCK” has already been reserved in the system.

”COM1~COM9, LPT1~LPT9, AUX, CON, PRN, NUL, CLOCK” has already been reserved in the system.

6

The letter which cannot be used as a file name is contained

”/,;,:,*?"<>|\”, space or Tab is used for the file name.

Do not use ”/,;,:,*?"<>|\”, space and Tab when naming the title of the file.

7 The file is not chosen.

The file to send or receive is not selected.

Retry after selecting the file to send or receive.

8 It failed in this software receiving a file.

Error has occurred while receiving a parameter file, machining program file or maintenance data.

Confirm the following items and retry. Confirm: - that there is no problem in the file system of the connected NC. - that no communication error is occurring.

9 It failed in this software receiving a file.

Error has occurred while sending a parameter file, machining program file or maintenance data.

Confirm the following items and retry. Confirm: - that there is no problem in the file system of the connected NC. - that no communication error is occurring. - that the connected NC is running.

10 The file not existing is specified.

The designated file does not exist.

Confirm that the designated file exists and retry.

30

Page 30: Remote monitor tool Operating Manual

No. Message details Remedy

11 This software failed in deletion of a file.

Deletion of the file was attempted in overwriting the file with the same name, but the deletion has failed.

When overwriting a file on PC side, confirm that the property of the file is not set to "read only". When overwriting a file NC side, confirm the following items and retry. Confirm: - that there is no problem in the file system of the connected NC. - that no communication error is occurring. - that the connected NC is not running.

12 Send data size is larger than the memory capacity.

As the NC memory is full, data cannot be input.

Delete unnecessary data from the NC memory or reduce the send data size to meet the NC memory capacity. And then try again.

13 Data protection is ON.

Operation is disabled as the data protect is ON.

Cancel the data protect and then try again.

14 No option. The option is not included. Check the specifications.

15 Failed to compare. The NC does not support the compare function.

Check the NC version.

16 Failed to send due to wrong data format or content.

The send data is illegal. Check the contents of the send data.

17 The file does not exist. The file to compare with does not exist in the NC.

Send the file to compare and then try again.

18 It is not in emergency state.

Operation was disabled, as the NC was not in emergency stop state.

Set the NC in emergency stop state, and then try again.

19 The program No. is illegal.

The program No. in the program to send is not correct.

Open the program file and change the program No. to be within the range between O1 and O99999999. Change the program No., if you wish to register "MDI.PRG" as a user program.

20 The file name or directory is illegal.

The file name or the directory designated to send the file to is not correct.

Try again after confirming that: - the NC directory is correct, and - the file name and its extension are correct.

31

Page 31: Remote monitor tool Operating Manual

10.2How to cancel Windows fire wall block

To enable automatic search in Windows Vista and Windows7, exclude the Remote monitor tool connection from Windows Firewall. Below are the cancellation methods for each OS. For Windows Vista 1) Open [Control Panel] and select [Security] -> [Windows Firewall]. 2) Select [Change settings].

3) When the "User Account Control" dialog appears to ask if you wish to continue, select

[Continue]. 4) Select the [Exceptions] tag on "Windows Firewall Settings" and check the checkbox of [CNC

Remote Monitor].

5) Press the [OK] button to enable the setting.

32

Page 32: Remote monitor tool Operating Manual

For Windows7 1) Open [Control Panel] and select [System and Security] -> [Windows Firewall]. 2) Select [Advanced settings].

3) Select [Inbound Rules] from [Windows Firewall with Advanced Security] and select the first

item [CNC Remote Monitor] to open the property.

33

Page 33: Remote monitor tool Operating Manual

4) Select the [General] tag on "CNC Remote Monitor Properties" and then select [Allow the

connection].

5) Press the [OK] button to enable the setting. 6) In the same way, select [Allow the connection] for the second item [CNC Remote Monitor].

10.3Obtaining the authority to operate the keys Press [F5] or [OPERATE] to obtain the NC screen operation authority when the NC is being operated via the other display unit (Remote monitor tool, GOT's CNC monitor screen, NC's dedicated display or WindowsCE display).

34

Page 34: Remote monitor tool Operating Manual

10.4Hosts files

If the Hosts file has been prepared, the connected NC name, etc. can be displayed on the list of the connection designation dialog box.

Create the Hosts file following the below format and store it under the name of “C64Hosts” in the [C:\Program files\MITSUBISHI CNC\Remote monitor tool] folder (installation folder).

<Format> [IP Address] [the connected NC name, etc.] - A comment comes after the # mark. - Leave one or more space or Tab space after the IP address. - Use up to 20 characters for the connected NC names, etc. excluding a space and Tab space. - Up to 256 connection destinations can be registered.

* The available character codes are ASCII and Shift JIS only. [Example] List of NCs to connect with # 192.168.1.2 SP110 192.168.1.3 SP111 192.168.1.4 SP112 192.168.1.5 SP113 192.168.1.6 SP114 192.168.1.7 SP115

35

Page 35: Remote monitor tool Operating Manual

36

10.5Enabling to send a parameter file and a machining program file

Add "DOWNLOAD=1" to the “ReC64Monitor.ini” file which exists in the installation directory to enable to send a program file and a machining program file. [Example] [COMMUNICATION] DOWNLOAD=1 <Location to store the “ReC64Monitor.ini” file> Normally the file is stored in the following folders. If you have changed the installation destination, the file is stored in the installation folder. - For Windows 2000 and XP:

C:\Program files\MITSUBISHI CNC\Remote monitor tool\ - For Windows Vista and Windows 7:

C:\Users\(User name)\AppData\Local\VirtualStore\Program Files\MITSUBISHI CNC\Remote monitor tool\

* The name of user who executes Remote monitor tool is displayed in (User name). * If the "AppData" directory does not appear, select [Control Panel] -> [Folder Options] -> [View] -> [Advanced settings] -> [Files and Folders] -> [Hidden files and folders] and check [Show hidden files, folders, and drives].