HSE Health & Safety Executive Recommended practice for the rapid inspection of small bore connectors using radiography Prepared by AEA Technology plc for the Health and Safety Executive 2005 RESEARCH REPORT 294

Upload: others

Post on 17-Mar-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

HSEHealth & Safety

Executive

Recommended practice for the rapid inspectionof small bore connectors using radiography

Prepared by AEA Technology plc for the Health and Safety Executive 2005

RESEARCH REPORT 294

Page 2: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

HSEHealth & Safety

Executive

Recommended practice for the rapid inspectionof small bore connectors using radiography

S F Burch (BA, Ph D) and N J CollettAEA Technology plc

551.11 Becquerel AvenueHarwell International

Business centreHarwell

OxfordshireOX11 0QJ

This document covers recommended practice for the radiographic inspection of corrosion in small borepiping and in the small bore connections to larger diameter main pipes. Inspection of this type ofcomponent is not covered by any internationally recognised standards or procedures, and there istherefore a need for guidance on recommended practice.

Recommendations are given concerning techniques for detection of corrosion within different regionsof small bore connectors and their junction with main pipes. A distinction is drawn between corrosion inthe form of relatively uniform loss of wall and isolated corrosion pits. Recommendations are givenregarding the key technical aspects of in-situ radiographic inspection techniques including radiationsources, film types, computed radiography systems, positioning of the source and film (or filmlessplate) and methods for reduction in exposure time.

This report and the work it describes were funded in part by the Health and Safety Executive (HSE). Itscontents, including any opinions and/or conclusions expressed, are those of the authors alone and donot necessarily reflect HSE policy.

HSE BOOKS

Page 3: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

ii

© Crown copyright 2005

First published 2005

ISBN 0 7176 2939 2

All rights reserved. No part of this publication may bereproduced, stored in a retrieval system, or transmitted inany form or by any means (electronic, mechanical,photocopying, recording or otherwise) without the priorwritten permission of the copyright owner.

Applications for reproduction should be made in writing to: Licensing Division, Her Majesty's Stationery Office, St Clements House, 2-16 Colegate, Norwich NR3 1BQ or by e-mail to [email protected]

Page 4: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

CONTENTS Page 1 Introduction ........................................................................................................................... 1 2 Radiographic Methods For Corrosion Detection In Pipes .................................................... 2

2.1 Tangential method............................................................................................................. 2 2.2 Straight-through method ................................................................................................... 3 2.3 Both methods combined.................................................................................................... 5 2.4 Inspection of junction with main pipe............................................................................... 5

3 Radiography Equipment........................................................................................................ 9 3.1 Radiation Sources.............................................................................................................. 9

3.1.1 Type of source........................................................................................................... 9 3.1.2 Size and strength of sources .................................................................................... 10 3.1.3 Source containers and collimation .......................................................................... 10

3.2 In-situ inspection of plant................................................................................................ 11 3.3 Film and screens.............................................................................................................. 11

3.3.1 Conventional film.................................................................................................... 11 3.3.2 Fluorometallic screens............................................................................................. 12

3.4 Computed (filmless) radiography.................................................................................... 12 3.4.1 Image Processing on filmless systems .................................................................... 13

3.5 Dimensional Indicators ................................................................................................... 14 4 Equipment setup.................................................................................................................. 15

4.1 Inspection Techniques..................................................................................................... 15 4.1.1 Technique 1: Flat film, beam axis perpendicular to main pipe ............................... 15 4.1.2 Technique 2: Film flat against connector, beam axis perpendicular to main pipe .. 15 4.1.3 Technique 3: Film flat against connector, beam axis parallel to main pipe ............ 16 4.1.4 Technique 4: Angled Film flat, beam axis perpendicular to main pipe .................. 17

4.2 Source to film distance.................................................................................................... 17 4.3 Exposure times and film density ..................................................................................... 21

4.3.1 Fine grain film with lead screens ............................................................................ 21 4.3.2 Other film/detectors for reduced exposure times .................................................... 22

4.4 Image Quality Indicators ................................................................................................. 23 5 Overall performance............................................................................................................ 24

5.1 Image quality................................................................................................................... 24 5.2 Examples ......................................................................................................................... 25

5.2.1 Comparison between Ir 192 and Se 75 using fine grain film with lead screens...... 255.2.2 Example of application to larger diameter (10 inch) main pipe specimens ............ 27 5.2.3 Example of use of fine grain film with fluorometallic screens ............................... 29 5.2.4 Examples obtained with computed radiography systems........................................ 30

5.3 Inspection of approximately uniform corrosion/erosion ................................................. 32 5.3.1 Wall loss external to the main pipe ......................................................................... 325.3.2 Wall loss within the main pipe wall ........................................................................ 32

5.4 Detectability of isolated corrosion pits............................................................................ 33 6 Summary of relevant safety standards and legislation ........................................................ 35 7 Main recommendations ....................................................................................................... 35 8 Recommendations for further work .................................................................................... 37 9 Acknowledgements ............................................................................................................. 37 10 References ........................................................................................................................... 37

iii

Page 5: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

iv

Page 6: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

EXECUTIVE SUMMARY This document covers recommended practice for the radiographic inspection of corrosion in small bore piping and in the small bore connections to larger diameter main pipes. Inspection of this type of component is not covered by any internationally recognised standards or procedures, and there is therefore a need for guidance on recommended practice. The information obtained from the HOIS2000 radiographic evaluation trials is used as the basis for this recommended practice document. Appropriate standards are also referenced, including ISO 2919: 1999 and ISO 3999-1:2000, which cover radiation protection aspects of gamma ray sources and containers. BS EN 1435 which is a standard for radiographic examination of welds is also referenced. Recommendations are given concerning techniques for detection of corrosion within different regions of small bore connectors and their junction with main pipes. A distinction is drawn between corrosion in the form of relatively uniform loss of wall and isolated corrosion pits. Recommendations are given regarding the key technical aspects of in-situ radiographic inspection techniques including radiation sources, film types, computed radiography systems, positioning of the source and film (or filmless plate) and methods for reduction in exposure time.

v

Page 7: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

vi

Page 8: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

1 INTRODUCTION

The inspection of complex geometries was identified as a key area for work within the HOIS2000 core programme, at the start of the new joint industry programme (HOIS2000) in April 1999. Standard NDT methods are routinely used to inspect vessels, tanks and medium and large bore pipework. However, the standard methods have difficulties in application to more complex components and fittings such as connectors, especially those of small bore, tight bends, T-pieces, injectors, etc. Speed of inspection was also identified as a key parameter. In the year 2001/02, an evaluation of radiographic techniques for the inspection of corrosion in small bore connectors and weldolets was carried out (Burch & Collett, 2002). For these trials, specimens containing simulated corrosion in the small bore connectors attached to larger diameter main pipes were first designed and then manufactured. These specimens contained controlled and accurately known levels of corrosion. The trials on these small connector specimens involved evaluation of current radiographic techniques followed by an investigation of more novel radiographic techniques which would be capable of faster application to plant. These included the new computed (filmless) radiographic systems which are beginning to find application to industrial NDT. Inspection of this type of component is not covered by any internationally recognised standards or procedures, and there is therefore a need for guidance on recommended practice. The information obtained during the radiographic trials is used as the basis for this recommended practice document, covering the inspection of small bore connectors for corrosion using radiographic methods. Appropriate standards are referenced, including ISO 2919 and ISO 3999-1, which cover radiation protection aspects of gamma ray sources and containers, as well as BS EN 1435 which is a standard for radiographic examination of welds. Recommendations are given concerning techniques for detection of corrosion within different regions of small bore connectors and their junction with main pipes. A distinction is drawn between corrosion in the form of relatively uniform loss of wall and isolated corrosion pits. Recommendations are given regarding the key technical aspects of in-situ radiographic inspection techniques including radiation sources, film types, computed radiography systems, positioning of the source and film (or filmless plate) and methods for reduction in exposure time. It is important to note that the trials were completed under laboratory conditions inside an exposure compound or similar controlled and uncluttered environment. This made it straightforward to set-up the radiography equipment in such a way as to achieve safe radiation dose rates in a small controlled area, whilst using highly penetrating radioisotopes and the source to film distances (SFD) recommended in this document. The practical application of these recommendations under typical site conditions may need modification for particular circumstances. In-situ, local access to small bore connectors is often restricted, limiting the choices for the source position and shielding. However, the appropriate legislation requires the radiography contractor to conduct a prior risk assessment of the work and it is at this stage that a practical assessment should highlight potential difficulties so that solutions can be planned in advance. In addition it should be noted that the laboratory samples on which the trials were carried out did not contain liquid or scale. However, due to the relatively small diameter of the small bore piping and weldolets (the maximum internal diameter was 26 mm), it is not anticipated that the presence of a low density liquid such as oil or water, or relatively low density scale would

1

Page 9: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

significantly affect the performance of the radiographic techniques evaluated. Nevertheless further trials could be carried out to check this, if considered necessary. Note that specific recommendations are highlighted in the document using bold text. 2 RADIOGRAPHIC METHODS FOR CORROSION DETECTION

IN PIPES

Using radiography, corrosion can be detected using two different exposure set-ups or “modes”, both of which can often be used on the same radiograph of a small diameter component such as a small bore connector. 2.1 TANGENTIAL METHOD

Firstly, when used in tangential mode, a radiograph shows a direct image of the pipe wall. Corrosion producing loss of wall can then be detected and measured by the reduction in the imaged wall thickness, as illustrated in Figure 2.1.

X or gamma-ray source

Pipe

Film

Extended area of corrosion

Image of pipe wall on film

Figure 2.1 Principle of tangential radiography The extent of the loss of wall due to extended areas of either internal or external corrosion can be measured directly from the radiographic images, provided appropriate calibration techniques are used to allow for the enlargement of the radiographic image caused when the distance between the object and film is non zero - see Section 3.4 for further details. The tangential method inspects only a small extent of the circumference of the pipe for a single source/detector position. Thus an isolated pit is likely to fall outside the inspection region,

2

Page 10: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

unless a several radiographs are taken around the circumference of the pipe (by moving the source and detector together circumferentially around the pipe). For small bore connectors attached to larger diameter pipes, geometric constraints generally preclude use of many different circumferential angles for the radiation beam (see Section 4.2 for further details). Also, even if an isolated pit is located within the inspection region, its through wall extent will be underestimated unless it is positioned very close to the exact position at which the radiation pipe forms a tangent to the pipe wall, as illustrated in Figure 2.2. The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally be used for isolated corrosion pits, unless their circumferential location has already been established using for example the density difference or straight-through method (see below).

Figure 2.2 Illustration of coverage region for tangential radiography and the location of an

isolated pit for which the through wall extent would be underestimated 2.2 STRAIGHT-THROUGH METHOD

Radiography can also be used in a “straight-through” mode, whereby corrosion can be detected by the increased film density produced by the loss of material (see Figure 2.3). With this method, the size of the corrosion pits in the circumferential and axial directions can be measured from the radiograph, provided methods are used for calibration of distances - see Section 3.4. However, the through wall extent of the corrosion cannot be measured directly, although some information on this can be gained from the magnitude of the change in film density.

3

Page 11: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

This method is recommended for the detection of isolated corrosion pits, and can also be used for detection of extended areas of corrosion.

X or gamma-ray source

Pipe

Film

Corrosion

Image of corrosion pit onfilm

Figure 2.3 Detection of corrosion by increased film density in ‘straight-through’ mode

4

Page 12: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

2.3 BOTH METHODS COMBINED

For relatively thin-walled, small bore pipes and weldolets, a single radiograph has sufficient dynamic range and size to show the presence of corrosion by both of the tangential and density difference methods. Note that the source position should then be central to the small bore pipe, as shown in Figure 2.4.

X or gamma-ray source

Small bore pipe

Film

Figure 2.4 Radiography of a small bore pipe, combining both the tangential and straight-through modes in a single radiograph

For this combined type of radiography, as shown in Figure 2.4, the tangential method can be applied to both sides of the pipe on the same radiograph, and the region in between will show any loss of wall by increased film density. 2.4 INSPECTION OF JUNCTION WITH MAIN PIPE

For small bore connectors, the junction with the main pipe leads to there being a distinction between the sections of the connector which are external to the larger main pipe wall, and the region within the main pipe wall, as illustrated in Figure 2.5. For detection of corrosion within the wall of the main pipe, substantially larger metal paths need to be penetrated, compared with the sections external to the main pipe wall.

5

Page 13: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

Source

Film/detector

Corrosionexternal to

main pipe wall

Corrosion withinwall of main pipe

Tangentialpath T

Figure 2.5 Small bore connector inspection showing different locations of potential corrosion

sites, and maximum path through wall of main pipe, T For a pipe with wall thickness WT and outside diameter OD, the maximum metal path, T, through the pipe wall occurs for a line forming a tangent with the inner diameter (as shown on Figure 2.5). This maximum path is given by

( ) WT- ODWT 2 T = (2.1) Note that this applies to any line drawn through the pipe, forming a tangent to the inner surface of the pipe. Thus T is independent of the source position. Values for the maximum path, T, through schedule 40, 80 and 160 pipes of various diameters are given in Table 2.1, for ease of reference. Note that these paths are generally much larger than twice the wall thickness of the main pipe. For example, T is 100 mm or larger for 8 inch schedule 80 pipes and above.

6

Page 14: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

Table 2.1 Maximum paths through schedule 40 & 80 pipes of various diameters

Nominal Bore

(inches)

Outside diameter, OD

(mm)

Schedule Wall thickness, WT

(mm)

Max Tangential

path (mm)

2 60.3 40 3.9 29.7 80 5.5 34.7 160 8.7 42.4

3 88.9 40 5.5 42.8 80 7.6 49.7 160 11.1 58.8

4 114.3 40 6.0 51.0 80 8.6 60.3 160 13.5 73.8

5 141.3 40 6.6 59.6 80 9.5 70.8 160 15.9 89.3

6 168.3 40 7.1 67.7 80 11.0 83.2 160 18.3 104.8

8 219.1 40 8.2 83.2 80 12.7 102.4 160 23.0 134.3

10 273.0 40 9.3 99.0 80 15.1 124.8 160 28.6 167.2

12 323.8 40 10.3 113.6 80 17.5 146.4 160 33.3 196.7

The same information is presented graphically in Figure 2.6, which shows the maximum path lengths as a function of pipe diameter.

7

Page 15: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

Tangential path lengths

0

20

40

60

80

100

120

140

160

180

200

0 2 4 6 8 10

Pipe nominal bore (inch)

Tang

entia

l pat

h (m

m)

12

Schedule 40Schedule 80Schedule 160Limit for Se 75

Se 75

Ir 192

Co 60

Figure 2.6 Maximum (tangential) path lengths through the walls of pipe of different diameter. The maximum penetrated thicknesses for different isotope sources, as recommended in BS EN

1435 are also shown. Also shown on Figure 2.6 are the maximum penetrated thickness for Se 75, Ir 192 and Co 60, as recommended by BS EN 1435 for class A radiography. It can be seen that even the smaller diameter main pipes have maximum path lengths which exceed the recommended limit of 40 mm for Se 75. For Ir 192, the limit of 100 mm is reached for a 6 inch 160 schedule pipe, a 8 inch schedule 80 pipe and a 10 inch schedule 40 pipe. Note that in some cases it is possible to exceed the thickness limits shown in Figure 2.6, using for example computed radiography. For larger path lengths, Co 60 has more penetrating power but is much less widely used in the oil and gas industry due to greater radiation safety hazards. For further information on wall thickness and source selection, see Section 3.

8

Page 16: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

3 RADIOGRAPHY EQUIPMENT

3.1 RADIATION SOURCES

3.1.1 Type of source

The majority of in-situ on site radiography is carried out using gamma-ray emitting isotope sources, although portable, light-weight X-ray sources can also be used in cases where the need for electrical power and high voltages do not cause significant safety issues. For the inspection of the sections of the small bore connectors external to the main pipe, the two recommended isotope sources are Iridium 192 and Selenium 75. Of these, Iridium 192 is a conventional isotope source used for inspection of medium steel thicknesses (c. 10-100 mm, Halmshaw, 1995). The energy of the majority of the gamma ray photons emitted is around 300 keV and the half-life is 74 days. The isotope source Selenium 75 has been developed for industrial radiography more recently than Ir 192. It has a lower energy gamma ray spectrum than Ir192 with main peaks at 137keV and 265keV and a longer half life (120 days). Source strengths are available between about 2 and 80 Curies with physical sizes ranging from 1x1 mm to 3x3 mm. Sources and their containers should comply with the requirements of ISO 2919: 1999 and ISO 3999-1:2000, which include integrity testing to 800° C. Due to the lower gamma ray energies emitted by Selenium 75 compared with Iridium 192, Se 75 gives radiographs with higher contrast on components with moderate steel thicknesses, including the majority of small bore piping. Source selection should be made according to the following criteria: (i) Corrosion in small bore piping external to main pipe wall • For detection of small isolated corrosion pits and sizing in the circumferential and axial

directions, by the density difference (or “straight-through”) method described in Section 2, use of Se 75 would be preferred to that of Ir 192 due to the higher contrast obtained with the former source.

• For detection and through wall sizing of generalised loss of wall by the tangential method

described in Section 2, both Ir 192 and Se75 have similar fit-for-purpose capabilities. (ii) Corrosion in main pipe wall at junction with small bore connectors • For main pipes which have maximum penetrated paths less than 50 mm (see Table 2.1 and

Figure 2.6), both Ir 192 and Se75 have similar fit-for-purpose capabilities. • Ir 192 is recommended for main pipes for which the main path T exceeds c. 50 mm (see

Table 2.1 and Figure 2.6), but is less than c. 100 mm. • For maximum path lengths of order 100mm and larger even Ir 192 will not provide

adequate penetration and use of a gamma ray source generating a higher photon energy (e.g.

9

Page 17: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

the 1 MeV photons generated by Cobalt 60) should be considered, although it is recognised that there are additional safety issues involved in the use of this type of source.

• Se 75 with computed radiography (see Section 3.4) may be applicable to paths greater than

50 mm (up to 70 mm), but this was could not be verified for small bore piping inspection during the HOIS2000 radiographic evaluation trials due to the limited range of specimens available.

3.1.2 Size and strength of sources

In the UK offshore environment, the limit for Ir 192 is normally 25 Ci, but depending on any other sources are already in store, this may limit the maximum size of a single source. Thus sometimes single sources can be limited to c. 10 Ci, but higher strength sources in the range 15 to 40 Ci have been used with special risk assessments. For Se 75, higher activity sources can be used, due to the lower penetrating power of the radiation produced. Source strengths of up to 30 curies can be used but there is no generally accepted upper limit offshore. Note that radiography contractors should state the maximum strength isotopes within their Local Rules as required by IRR 1999. The source size for inspection of small bore piping should be chosen taking account of the limits on geometric unsharpness given in Section 4.2. Typically source dimensions for this application will be about 2mm. On occasion, use of smaller sized sources (e.g. 1 x 1 mm) may be considered preferable, as these will lead to smaller geometric unsharpnesses for the same source to film distances. For Ir 192, newly manufactured high activity sources of size 1.2 x 1.2 mm can have a strength of c. 8 Ci, and a 2 x 2 mm source can have an activity of c. 44 Ci. The effective source size for geometric sharpness calculations should be used to calculate the required source to film distance, as given in Section 4.1. Larger physical sized sources will require greater source to film distances than smaller sized sources to obtain the same geometric unsharpness. 3.1.3 Source containers and collimation

The source containers should conform with the requirements for source containers given by ISO3999-1:2000 or BS5650:1978 ISO 3999-1977 and any applicable national standards. Conventional projection equipment can be used for the radiography of small bore piping, provided the requirements of the current radiation safety regulations are complied with. For these systems, a large radiation controlled area (radius ≈100 m) is normally needed, which often requires out of hours working, or even shutdown of plant. Systems which keep the source within a single container or single container/collimator assembly are now available (e.g. SCAR, SafeRad) which allow a much smaller size of controlled area (of order 1m - 5 m). These systems reduce radiation doses to operators, and the small size of the controlled area generally means that plant operation does not need to be interrupted when site radiography is underway.

10

Page 18: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

The selection of an appropriate source container and deployment system depends on the balance of the above factors for each individual site and inspection application, together with economic considerations. Careful collimation of the sources is recommended to minimise unwanted radiation, and reduce the effects of scatter on the radiograph. 3.2 IN-SITU INSPECTION OF PLANT

Use of gamma ray radiography equipment for in-situ inspection of plant involves significant safety issues associated with the use of ionising radiation. The appropriate mandatory safety regulations appropriate to the plant must be adhered to (IRR 1999 in the UK). These include the construction and maintenance of radiation controlled areas, by means of appropriate barriers. Pre-planning of the inspection work to be carried out on a plant is required, to include both a risk assessment and a practical assessment of how the source container and shielding will be placed (IRR 1999). 3.3 FILM AND SCREENS

3.3.1 Conventional film

Radiographs with the highest quality in terms of spatial resolution, contrast and granularity will be achieved with a fine grain high contrast film. All other detection techniques described in this document give some reduction in image quality, but with the main benefit of reduced exposure time. Use of different types of film for weld radiography is covered by BS EN 1435. In this standard, two classes of radiography are defined, class A (basic) and class B (improved). The class B is generally used for more demanding applications such as detection of fine cracks. The detection of corrosion, which is a form of volumetric defect, is considered less demanding for radiography than fine crack detection, and hence class A radiography, as defined by BS EN 1435 should generally be sufficient. For Class A radiography and Se 75/Ir 192 sources, BS EN 1435 recommends a C 5 film class (as defined is BS EN 584-1), common examples of which are Agfa D7, Fuji 100, Kodak AX and DuPont 70. Use of front and back lead screens is also required; a thickness of 0.1mm for both screens is consistent with the requirements of BS EN 1435. Thus the recommended standard film class is C 5 (Agfa D7, Fuji 100, Kodak AX and DuPont 70), although it is recognised that for particular applications such as detection of very slight corrosion in very small wall thickness pipes, a finer grain film may be required. The advantages of fine-grained film used with lead screens are: • Provides the highest spatial resolution and overall image quality of all currently available

detection systems. • Low-cost, unless used in very large quantities. • Well established, well understood characteristics and universally accepted. • Forms a direct hardcopy which can be readily archived Disadvantages of film include:

11

Page 19: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

• Relatively long exposure times • Need for film development which involves use of a dark room, and safe use and disposal of

the necessary chemicals. • Accurate dimensional measurements not straightforward 3.3.2 Fluorometallic screens

Fluorometallic screens provide an alternative to lead intensifying screens and, when used with fine grain film (Agfa D7), give significant reductions in exposure times, albeit at the expense of some loss of image sharpness. The results of the HOIS2000 evaluation trials (Burch and Collett, 2002) showed that when used with Ir 192, NDT 1200 fluorometallic screens with fine grain film gave approximately a factor five reduction in exposure time compared with fine grain film used with lead screens (see Section 4.3). Use of fluorometallic screens with medium grain film (Agfa F8) was also investigated in the HOIS2000 evaluation trials. A further reduction in exposure time was obtained, but with a significant reduction in image quality. This combination is not therefore generally recommended for applications requiring high sensitivity. However if the tolerable defect sizes are large and hence the required sensitivity is low, then this technique could provide a fit for purpose method for reducing exposure time. 3.4 COMPUTED (FILMLESS) RADIOGRAPHY

Technical developments have led to systems that do not rely on film as the detection medium. These fall into two categories, those which use a storage phosphor technology and those employing an array of semiconductor detectors. Only the phosphor technology has been tested within this programme of work. Originally developed for medical applications the storage phosphor technology is now finding use in industrial radiography. Storage phosphor systems use a flexible plate coated with a type of phosphor that stores the incident radiation as a latent image within the phosphor (composition used depends on the manufacturer). The latent image can be read off the plate into a computer as a digital picture using a special scanner. This system is sometimes referred to as computed radiography (CR) or digital radiography. Imaging plates have good linearity and high dynamic range, exceeding conventional film in both cases. They also have a good sensitivity to gamma and X-rays. The same plate can be used many times. The limiting factor is mechanical wear and damage to the plate rather than degradation in the luminescent properties. In practical implementations the phosphor is coated onto a flexible substrate and the plate can be used like a conventional film. Readout is achieved by scanning over the plate with a fine spot of laser light at a suitable wavelength to stimulate the photoluminescence of the phosphor material. Typically the scan lines are 100 microns apart (10 lines per mm ) although some scanners can achieve 50 microns ( 20 lines per mm ). After readout some residual image may remain on the plate so to erase it fully a very bright light is used. Ambient light does not cause an image on the plate unlike conventional film, although very bright light can cause erasure of a stored image as noted. However overall the plates require less precautions against ambient light exposure than conventional film.

12

Page 20: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

The advantages of the computed radiography (filmless) systems include: • Significantly reduced exposure times compared with fine grain film used with lead screens. • Greater exposure latitude than film (i.e. acceptable images can be obtained over a broader

range of exposures than with film). • Greater exposure latitude also permits reasonable interpretation of a large range of material

thicknesses within the same image reducing the need for multiple exposures required by film.

• No chemical processing needed (no disposal of chemicals, no need for dark room). • The filmless plates can be re-used many times. • Images directly read into a computer for subsequent enhancement and straightforward on-

screen measurements of wall-thickness. • Multiple ‘film-like’ hard copies of images can be produced which are interpretable on

standard film viewers. The disadvantages of this technology include: • Relatively new recording medium, characteristics not fully understood or documented. • Resulting radiographs have lower spatial resolution than fine grain film used with lead

screens (comparable with fluorometallic screens used with fine grain film). • High capital cost of system. • ‘Film-like’ hardcopying facility is non-standard and additional cost. 3.4.1 Image Processing on filmless systems

For computed (filmless) radiography, the raw digital images are generally stored on disc in a proprietary 12-bit/pixel format. On some systems, various image processing and enhancement techniques can then be applied to obtain the image displayed on the PC monitor. Various enhancement options can be available, including: • Contrast amplification • Edge contrast • Latitude reduction • Noise reduction Usually the amount of enhancement within each of the above categories can be controlled by an integer parameter. This processing can have a significant effect on the on the perceived image characteristics. To the eye, the processed image can be made to appear substantially sharper than the one without processing, but the apparent noise level (granularity) on the processed image is then higher than that without processing. By varying the processing parameters it is possible to obtain many different effects, with different trade-offs between noisy/granularity level and apparent image/edge sharpness. It is clear that the values selected as optimum for the various image processing parameters are somewhat subjective, and different operators may well prefer to use different combinations of values. In addition, the values can be varied depending on the requirements of the inspection application.

13

Page 21: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

Nevertheless, this type of image processing can be an effective additional option, when using computed (filmless) radiography. It should be noted that this processing is not necessarily available on all computed radiography systems. The above spatial image processing operations can be followed by interactive adjustment of contrast and brightness (sometimes referred to as level control) to obtain the “optimum” display of the processed images on the PC monitor. Images in standard file formats (e.g. jpeg) of the current enhanced image can be created and stored on disc. Note that once in this format, only very limited further processing or enhancement is possible. 3.5 DIMENSIONAL INDICATORS

For applications requiring accurate dimensional measurements, such as wall thickness measurement by the tangential radiography technique, it is necessary to calibrate the dimensions measured from a radiograph. For a film radiograph, this is because a non zero component to film distance causes the image of the component to be magnified by the ratio (source to film distance)/(source to component distance). For a digital radiograph, the pixel size needs to be calibrated in terms of real dimensions (e.g. mm on the component) in order to make accurate on-screen dimensional measurements. Techniques for calibrating dimensions include use of known pipe or small bore ODs or IDs if available, but inaccuracies may arise due to possible presence of corrosion. An alternative is the inclusion of an appropriate calibration object(s) in the radiograph of precisely known dimension, such as a ball bearing of known diameter, at the same distance from the film/detector as the object of interest, as illustrated in Figure 3.1.

Figure 3.1 Comparators for calibration of dimensional measurements taken from radiographs

Radiography contractors should produce a written procedure detailing how wall thickness measurements will be made in a consistent and accurate manner, particularly if this technique is used for condition monitoring of specific inspection points

14

Page 22: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

4 EQUIPMENT SETUP

This section gives recommendations concerning the setup of the radiographic equipment detailed in Section 3, for the inspection of small bore pipes, and their connection with the main pipes. 4.1 INSPECTION TECHNIQUES

The junction between small bore piping and a larger diameter pipe can cause physical restrictions on the placement of the source and film/detector plate. In particular, the presence of the larger diameter pipe can make it difficult to place the film/detector plate in close proximity to the small bore connector. Various different techniques can therefore be used to inspect these components, as follows. 4.1.1 Technique 1: Flat film, beam axis perpendicular to main pipe

In technique 1, the radiation beam axis is arranged perpendicular to the axis of the main pipe, and the film/detector is kept flat and perpendicular to the radiation beam, as shown in Figure 4.1. The simplest and most convenient location for the film/detector is then tangential to the OD of the main pipe, which gives an appreciable stand-off between the film and the small bore connector under inspection. This stand-off clearly increases with the diameter of the main pipe and requires a corresponding increase in the source to film distance to maintain a small geometric unsharpness as recommended in Section 4.2. 4.1.2 Technique 2: Film flat against connector, beam axis perpendicular to main pipe

To reduce the large source to film distances needed for the larger diameter main pipes, technique 2 was investigated in the HOIS2000 evaluation trials (Burch & Collett, 2002). This technique involves the film placed in direct (flat) contact with the small bore connector and curved around the circumference of the adjacent section of the main pipe, as shown in Figure 4.1. This allows smaller source to film distances to be used for larger diameter pipes, while maintaining the recommended maximum geometric unsharpness of 0.3 mm. Technique 2 is applicable to the detection of corrosion in the section of the small bore connector external to the main pipe. A source to film distance of c. 300 mm is recommended. Information can also be obtained on any corrosion within the wall of the main pipe, but as shown in Figure 4.1, the change of direction of the film as it curves around the circumference of the main pipe will lead to some distortion of the image. In the HOIS2000 evaluation trials this technique was applied successfully to specimens containing 10 inch schedule 40 pipes with a 300 mm SFD. Corrosion in the section of small bore connector external to the main pipe wall was clearly seen, with significantly reduced exposure times compared with Technique 1. Some information on the ID of the hole in the main pipe was also obtained, but the large metal path (c. 100 mm) made this feature difficult to image, even with increased exposure, in this case. With smaller diameter pipes (e.g. 6 inch or 8 inch) this would be a less significant problem. However, by its nature Technique 2 requires the detector to be flexible, so that if film is used, it cannot be housed in a rigid cassette. A possible further problem with the use of curved films, is pressure marking of the films, particularly on tight bends. Faster films (e.g. Agfa F8) are understood to be more prone to this than the fine grain films.

15

Page 23: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

With computed radiography systems it can be difficult to use this technique as the filmless plates, although in themselves are flexible, may be deployed within a rigid cassette. Some computed radiography systems do not however have this restriction.

Technique 1

Technique 2

Technique 3

Source Film

Technique 4

Figure 4.1 Different techniques for the radiographic inspection of the connections between small bore piping and larger diameter pipes. Technique 1 - beam axis perpendicular to pipe, flat film offset from small bore pipe; Technique 2 beam axis perpendicular to pipe, film flat against the small bore connector and curved around the main pipe; Technique 3 beam axis parallel to

pipe, film flat against the small bore connector and main pipe, and bent at 90° at the joint. Technique 4 –- beam axis perpendicular to pipe, flat film angled to reduce gap behind the

connector 4.1.3 Technique 3: Film flat against connector, beam axis parallel to main pipe

Technique 3 is used to obtain radiographs with the beam axis parallel with the main pipe axis, as illustrated in Figure 4.1. In this case, inspection of only the section of the small bore connector external to the main pipe is possible, but small SFD’s (e.g. 300 mm) can be used. The comments about the use of curved films given in Section 4.2.2 are equally applicable to this technique.

16

Page 24: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

4.1.4 Technique 4: Angled Film flat, beam axis perpendicular to main pipe

Technique 4 is a variant of Technique 1. Here the film/imaging plate was kept flat but is angled as shown to reduce the gap between the film and the connector. The reduction in the film to object distance (OFD) with this technique depends on the angle used for the film, relative to the beam direction. As shown in Figure 4.1, an angle of 45° would give an approximate factor 2 reduction in OFD, which would lead to a factor 2 reduction in the required SFD, resulting in an reduction in exposure time by a factor c. 4. The image distortion caused by the angled direction of the film was not a significant problem in the result obtained using this technique in the HOIS2000 evaluation trials. However the use of dimensional indicators (see Section 3.5) in this technique may lead to inaccuracies because of the varying object to film distance. Thus this technique is not recommended if the application requires accurate dimensional measurements to be taken from the radiographs. 4.2 SOURCE TO FILM DISTANCE

In general, a large source to film distance will minimise the unsharpness in the radiograph caused by the size of radiation source (known as geometric unsharpness). However, large source to film distances can lead to very long exposure times, and increased shielding difficulties. Thus trade-offs must be made, whilst ensuring acceptable image quality. However, there is no universally accepted method for the choice of the source to film distance which will provide a satisfactory radiographic technique (Halmshaw, 1995, p125) and existing standards from various countries differ widely. For example, BS EN-1435 uses unexplained formulae to determine the minimum source to film distance, as follows: For class A ("basic" techniques):

3/2

mmb5.7

df

⎟⎠⎞

⎜⎝⎛≥

For class B ("improved" techniques):

3/2

mmb15

df

⎟⎠⎞

⎜⎝⎛≥

where f is the source to object distance d is the source size b is the object to film/detector distance (which must be expressed in mm). The basis for the above formulae is not clear, and appears to be empirical at best since the 2/3 power law produces a dimensionally inconsistent equation, and b must be expressed in mm.

17

Page 25: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

An alternative approach for determining the minimum source to film distance is to ensure that the source to film distance is large enough to keep the geometric unsharpness of the radiographs below a certain value, hence giving radiographs with similar overall spatial resolution. For inspection of a small bore connector, the distances which should be used in calculating the geometric unsharpness due to the effective source size, d are shown in Figure 4.2. The terminology follows that used in BS EN 1435. The source to film distance (SFD) is the distance from the source position to the film or detector plane. The distance between the source and the object, f, should be measured from the source to the point on the connector nearest to the source, to give the most conservative value for the geometric unsharpness. For film/detectors which are not aligned normal to radiation beam, the distance to the film should be taken as the maximum distance from the source side of the component to the position on the film furthest from the component.

SFD

b

Source, sized Film/detector

f

Figure 4.2 Distances used in calculation of geometric unsharpness in small bore connector inspection

The corresponding distance from the object to the film b is then simply given by: b = SFD – f The geometric unsharpness on the film/detector is then given by Ug = (d . b)/ f However, the magnification, M, of the image is given by:

18

Page 26: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

M = SFD / f Calculating the geometric unsharpness in the plane of the object then gives: Ug' = Ug / M = (d . b) / SFD Note that this measure of unsharpness refers to the value appropriate to the object under inspection, and differs from the value Ug which refers to the value on the film/detector. For large object magnifications, it is clear that Ug' is the appropriate measure to use for assessing image quality in relation to object detail, and by extension, the same is true for the smaller magnifications normally used in site radiography of small bore piping (and other components for that matter). For the HOIS2000 evaluation trials on the small bore connectors (Burch and Collett, 2002), the geometric unsharpness in the plane of the object was c. 0.3 mm or better for most radiographs. This is considered to be a reasonable target value for the detection of a volumetric defect such as corrosion. For a given object to film distance, b, and source size, d, the source to film distance, SFD, should therefore be set so that Ug' is not more than 0.3 mm, i.e. SFDmin = (d . b)/0.3 It should be noted that fine grain film has a lower unsharpness than 0.3mm. For Ir 192 Halmshaw (1995, p 90), quotes a value of 0.17 mm for the unsharpness of fine grain film. The film unsharpness for Se 75 is less than this due to the lower photon energies involved. Thus larger SFD values than those given by the equation above would give some slight improvement in detail resolution. Table 4.1 shows calculated source to film distances needed to achieve the recommended geometric unsharpness of 0.3 mm, assuming an effective source size of 2.3 mm. The same information is shown graphically in Figure 4.3. Table 4.1 Source to film distances (SFD) recommended for Technique 1, assuming an effective

source size of 2.3mm and a geometric unsharpness of 0.3 mm

Nominal Bore

(inches)

Outside diameter, OD

(mm)

Small bore piping OD

(mm)

SFD required for Technique 1

(mm)

2 60.3 17 296 3 88.9 17 405

19

Page 27: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

4 114.3 17 503 5 141.3 21 622 6 168.3 21 725 8 219.1 27 943

10 273.0 27 1150 12 323.8 27 1345

Note that for the 2 inch – 3 inch OD main pipes, the SFD values are relatively small (300 – 400 mm), but for the 10 inch OD pipes and larger, the required SFD’s exceed 1000 mm, requiring substantial exposure times (see Section 4.3) when used with fine grain film.

Source to film distances recommended for Technique 1

0

200

400

600

800

1000

1200

1400

0 2 4 6 8 10

Main pipe nominal bore (inch)

Sour

ce to

film

dis

tanc

e (S

FD) (

mm

)

12

Figure 4.3 Recommended source to film distances for application of Technique 1 to the small

bore connections, for an effective source size of 2.3 mm. The pipe nominal bore refers to that of the main pipe to which the small bore pipe is connected. Smaller sized sources would require proportionally smaller source to film distance to maintain a geometric unsharpness of 0.3 mm.

For Techniques 2 and 3, a constant SFD of c. 300 mm is recommended to ensure the geometric unsharpness is within the limit set by the equation above. For Technique 4, a larger SFD is required, intermediate between the minimum value of 300 mm, and the values shown in Figure 4.3. The exact value should be calculated according the equation above and will depend on the angle of the film to the small bore pipe, and hence the maximum distance between the small bore pipe and the film/detector. Note that for a source size of smaller than 2.3 mm, the above recommended source to film distances can be reduced in direct proportion to the source size relative to 2.3 mm. Thus a 1.2 mm source would allow the above source to film distances to be reduced by a factor of two.

20

Page 28: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

4.3 EXPOSURE TIMES AND FILM DENSITY

4.3.1 Fine grain film with lead screens

For conventional radiography using fine grain film, exposures times should be chosen to obtain a density of c. 3 in the centre of the small bore connection, so that the density of the tangential wall thickness area is not too low. Table 4.2 gives a guide to the exposure times required for the inspection of small bore connectors using Technique 1 (i.e. flat film placed tangentially to the main pipe OD, radiation beam perpendicular to the main pipe). The times given are for an Ir 192 source with a strength of 10 Ci, and are based on exposures used for the HOIS2000 evaluation trials. For Se 75 sources, very similar exposure times were needed. Exposure times for different strength sources can be readily calculated, as exposure time is inversely proportional to source strength. For weldolets with larger (10 mm) wall thickness, increased exposure times will be needed by factors of c. 2 (for Ir 192) and c. 7 (for Se 75 – larger factor due to greater attenuation with this lower photon energy source). For Techniques 2 & 3 (see Section 4.2), the SFD is maintained at c. 300 mm irrespective of the nominal bore of the main pipe, so c. 3 min exposure time is required with a 10 Ci Ir 192 source. Table 4.2 Approximate exposure times for fine grain film for small bore connector inspection

using Technique 1 with a 10Ci Ir192 source

Nominal Bore

(inches)

SFD required for Technique 1

(mm)

Approximate exposure time for a sch. 40-80 small bore connector

(10 Ci Ir 192 source)

(min) 2 296 3 3 405 6 4 503 8 5 622 13 6 725 18 8 943 30

10 1150 45 12 1345 60

The approximate exposure times are also shown in Figure 4.4 in graphical form.

21

Page 29: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

0

10

20

30

40

50

60

0 2 4 6 8 10

Main pipe nominal bore (inch)

Expo

sure

tim

e (m

in)

12

Figure 4.4 Approximate exposure times for application of Technique 1 to schedule 40/80 small bore connections, assuming use of fine grain film with lead screens and a 10 Ci Ir 192 source of

size c. 2 x 2 mm. 4.3.2 Other film/detectors for reduced exposure times

The exposure times given in the section above can be reduced using various alternatives to fine grain film with lead screens, albeit with some reduction in image quality. Table 4.3 gives a guide to the exposure times needed with different film/screen combinations and also the newer computed (filmless) radiography systems. The exposure times are given for a 10 Ci source of either Ir 192 or Se 75 and for a source to film distance of 300mm.

Table 4.3 Approximate exposure times for different detection media and source combinations

using Technique 1 with 300 mm SFD (10Ci source in all cases).

Technique Exposure time for 10 Ci source, SFD

= 300 (min)

Exposure reduction factor relative to fine

grain film

Fine grain film with lead screens & Ir 192 3 1 Fine grain film with lead screens & Se 75 3 1 Fine grain film with fluorometallic screens & Ir 192

0.6 5

Computed (filmless) radiography systems & Se 75

0.2 – 0.8 4 - 15

Computed (filmless) radiography systems & Ir 192

0.06 50

22

Page 30: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

4.4 IMAGE QUALITY INDICATORS

In weld radiography, image quality indicators (IQIs) are used to verify that the sensitivity of the radiographs obtained during an inspection is within acceptable limits. For small bore connector radiography, this is most relevant to the detection of corrosion in the straight-through/density difference method (Section 2.2), but is less critical for the tangential technique which images the loss of wall directly. Various different IQI types are in use world-wide, including single wire IQIs (EN 462 Part 1), step hole IQIs (EN 462 Part 2) and duplex wire IQIs (EN 462 Part 5). The IQI should generally be placed on the source side of the small bore pipe. For wire IQIs, the wires should run across the pipe. The IQI needs to be positioned in a section of the pipe unlikely to be affected by corrosion, otherwise it is possible that the IQI will mask the corrosion. Table 4.4 is adapted from that shown in EN 1435 for class A radiography, and shows IQI sensitivities which should be achieved as a function of the wall thickness of the small bore pipe. Note that the minimum penetrated thickness is twice the values shown in Table 4.4, as the X and gamma rays penetrate both walls of the piping. For Ir 192, EN1435 allows lower sensitivities to be accepted for some thickness ranges, as shown in Table 4.4.

Table 4.4 IQI sensitivities for radiography of small bore piping, adapted from EN 1435

For all radiation sources other than Ir 192

For Ir 192

Small bore pipe wall thickness

(mm)

Wire IQI value Mean % sensitivity

Wire IQI value Mean % sensitivity

>2.5 to 3.5 W14 2.7 W14 2.7 >3.5 to 5.0 W13 2.4 W13 2.3 >5.0 to 7.5 W12 2.0 W10 3.2

>7.5 to 12.5 W11 1.6 W9 2.5 >12.5 to 16 W10 1.4 W9 1.8

In the HOIS2000 evaluation trials(Burch and Collett, 2002), the sensitivities of the radiographs were not assessed using IQIs, as the main aim of the trials was to establish detectability of different levels of corrosion. Further work is recommended to quantify the sensitivity of radiographs of small bore connectors using IQIs, and to compare the values obtained with those given in Table 4.4. For the computed (filmless) systems, use of Duplex IQIs which measure more directly the spatial resolution of the image should be investigated.

23

Page 31: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

5 OVERALL PERFORMANCE

5.1 IMAGE QUALITY

The different sources and detection media described in this document give differing image qualities. Table 5.1 gives a qualitative comparison between the results obtained, in terms of resolution/sharpness, contrast and noise/granularity level. These parameters were assessed using a simple scoring system, involving a number of stars between 1 and 3, with the “best” being 3 stars. It should be noted that the range from 1 to 3 stars was qualitative, and chosen to span the differences between the available results. The number of stars assigned to a particular technique is not therefore intended to provide a quantitative or linear measure of the parameter concerned (e.g. image resolution). Table 5.1 Qualitative comparison between results obtained with different radiographic sources

and detection media on sections of small bore connectors external to the main pipe wall.

Technique Resolution/ sharpness +

Contrast + Noise/ granularity +

Fine grain film with lead screens & Ir 192

*** ** ***

Fine grain film with lead screens & Se 75

*** *** ***

Fine grain film with fluorometallic screens & Ir 192

** ** **

Computed (filmless) radiography (Se 75) but without spatial image processing

** 1 ***

Computed (filmless) radiography (Se 75) with spatial image processing2

**(*) 1 * to *** depending on

processing parameters

Computed (filmless) radiography (Ir 192) with spatial image processing2

** 1 * to ** depending on

processing parameters

Notes: + Qualitative measure only – “more stars the better” (high contrast, high

resolution/sharpness, low noise) 1 Intrinsic contrast is difficult to quantify for computed radiography systems, due to use

of on-screen contrast/brightness control. 2 Spatial image processing can improve the apparent sharpness of the image, but often

at the expense of a significant increase in the noise/granularity level. Note that the highest quality images were the fine grain film radiographs obtained with Se 75. This is because, for the small bore connectors and weldolets (WT no more than 10 mm), which have relatively low maximum metal paths, the Se 75 source gave noticeably higher contrast than Ir 192 due to the lower mean gamma ray energies from Se75. When fine grain film is used with fluorometallic screens, a significant reduction in exposure time is obtained (see Section 4.3.2), but the resulting radiographs have appreciably lower spatial resolution and somewhat reduced contrast.

24

Page 32: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

The raw images obtained with two different computed radiography (filmless) systems were similar in quality, and had lower resolution than fine grain film (but shorter exposure times, as noted in Section 4.3.2). The spatial resolution of the raw images from the computed radiography systems was comparable with that obtained with fine grain film and fluorometallic screens. The spatial image processing package available with one of the computed radiography systems allowed different trade-offs between noise level and apparent image resolution/edge sharpness to be obtained, by varying the values of four available processing parameters. Thus, it was possible to improve the apparent image sharpness but only at the expense of an increase in noise level. 5.2 EXAMPLES

This Section gives examples of radiography of small bore connector specimens obtained during the HOIS2000 evaluation trials (Burch & Collett, 2002). These specimens contained simulated but realistic corrosion defects introduced into one end of the small bore pipes, prior to their welding onto the main pipes. In each case, a length of about 10-15 mm of simulated corrosion was introduced using a variety of “ad-hoc” techniques, which produced an irregular loss of wall approximately evenly distributed around the circumference of each small bore pipe. Superimposed on these relatively smooth variations (length scale several mm), were a number of small isolated “pits”. At around 10 mm from the end of each pipe, the loss of wall tapered down to zero. 5.2.1 Comparison between Ir 192 and Se 75 using fine grain film with lead screens

Figure 5.1 shows radiographs obtained using technique 1 (flat film, placed tangentially to main pipe OD) on 3 inch main pipe specimens, with the small bore connectors containing different levels of corrosion. The source used was Ir192, and the detection medium was fine grain film with lead screens. For further details, see the figure caption. Note that inevitably the techniques used to digitise and display the film radiographs in this report have caused a loss of image quality, compared with viewing the original film radiographs on a light box. Note that the wall loss on the moderate and severe cases of corrosion can be detected by the tangential method. Also, the hole through the main pipe wall can also be clearly seen, and corrosion here would have been detected, if present. On the original film radiographs the increased density in the centre of the connector image caused by wall loss in the “straight-through” radiography mode can also just be discerned for both the moderate and severe cases of corrosion, although the presence of the screw thread complicates matters.

25

Page 33: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

(a) (b)

(c)

Figure 5.1 Film radiographs obtained using Technique 1 with Ir 192 and fine grain film with

lead screens on threaded small bore connectors (OD 17 mm, WT 3.1 mm before introduction of screw thread) connected to 3 inch pipe (WT 7.6 mm). (a) no corrosion, (b) ‘moderate’ corrosion

(mean wall loss 24%), (c) ‘severe’ corrosion (mean wall loss 43%). Results courtesy of Oceaneering OIS plc.

Figure 5.2 shows results on a similar, but unthreaded set of small bore connectors using technique 1 applied with a Se 75 source, again with fine grain film and lead screens. The use of the lower photon energy (“softer”) Se 75 source has resulted in radiographs with significantly improved contrast, compared with the corresponding Ir 192 results given in Figure 5.1. Thus with Se 75, the corrosion can be readily detected by both the density difference and tangential methods, although only the tangential method allows the wall loss to be measured quantitatively.

26

Page 34: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

(a)

(b)

(c)

Figure 5.2 Film radiographs obtained using Technique 1 with Se 75 and fine grain film with

lead screens on small bore connectors (OD 17 mm, WT 3.1 mm) connected to 3 inch pipe (WT 7.6 mm). (a) no corrosion, (b) ‘moderate’ corrosion (mean wall loss 28%), (c) ‘severe’ corrosion

(mean wall loss 52%). Results courtesy of SafeRad Ltd 5.2.2 Example of application to larger diameter (10 inch) main pipe specimens

For larger diameter main pipes, use of technique 1 (flat film, placed tangentially to main pipe OD – see Figure 4.2) can lead to long exposure times (e.g. c. 45 min for 10 inch pipes with a 10 Ci source), when using fine grain film and lead screens (Table 4.2). To reduce exposure times, technique 2 can be used. This needs a flexible detection medium placed in direct contact with the small bore connector, and curved around the main pipe surface (see Figure 4.2). Corresponding exposure times are then only c. 3 min for fine grain film.

27

Page 35: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

Results with Ir 192 for technique 2 applied to larger diameter 10” pipe specimens are illustrated in Figure 5.3. In this case, the small bore connectors are set-through, and the majority of the corrosion is within the wall of the main pipe. Nevertheless, on Figure 5.3, evidence of wall loss in the “tangential mode” can be seen in the form of a general increase in the internal diameter of the connector, close to the main pipe wall, for both moderate and severe levels of corrosion.

(a)

(b)

(c)

Figure 5.3 Film radiographs obtained using Technique 2 with Ir 192 and fine grain film with

lead screens on plain small bore connectors (OD 17 mm, WT 3.9 mm) connected to 10” pipe (WT 9.3 mm). (a) no corrosion, (b) ‘moderate’ corrosion (mean wall loss

23%), (c) ‘severe’ corrosion (mean wall loss 53%). Note most of corrosion is within wall of main pipe. Results courtesy of Oceaneering OIS plc.

For this larger diameter main pipe, the path length through the main wall of the pipe is large (maximum 100 mm – see Table 2.1) which leads to under-exposure on the radiograph in this

28

Page 36: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

region of the image, and there is consequently little information concerning the presence/absence of corrosion in this region. However, by increasing the exposure time by a factor two or more, the hole in the wall of the main pipe can be imaged, allowing some detection of corrosion in this region of the component, albeit at reduced sensitivity compared with the sections of the connectors external to the main pipe wall. 5.2.3 Example of use of fine grain film with fluorometallic screens

Figure 5.4 shows a radiograph obtained with the faster detection medium of fluorometallic screens used with the fine grain film, compared with the results obtained with conventional lead screens. The specimen was that with ‘severe’ simulated corrosion already shown in Figure 5.1(c). It can be seen that the use of the fluorometallic screens has resulted in some reduction in image resolution, but, in this case, this has not affected the detectability of the wall loss using the tangential method. The exposure time was reduced by a factor 5 using the fluorometallic screens, as shown in Table 4.3.

(a)

(b)

Figure 5.4 Film radiographs obtained using Technique 1 with Ir 192 and fine grain film with lead and fluorometallic screens on threaded small bore connectors (OD 17 mm, WT 3.1 mm

before introduction of screw thread) connected to 3” pipe (WT 7.6 mm) with severe’ corrosion (mean wall loss 43%). (a) Fine grain film and lead screens, (b) fine grain film and fluorometallic

screens. Results courtesy of Oceaneering OIS plc

29

Page 37: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

5.2.4 Examples obtained with computed radiography systems

(a) Computed radiography System 1 Figure 5.5 shows an example of results obtained using Se 75 with a computed (filmless) radiography system on a 3 inch main pipe specimen with severe corrosion in the attached small bore connector (for comparison with the corresponding radiographs obtained with Ir 192 and film see Figure 5.4). This computed radiography system has additional facilities for spatial image processing (see Section 3.3.1). To show the effects of this processing, Figure 5.5 shows two images of the same component with and without spatial image processing. The unprocessed image shows an appreciable loss of spatial resolution compared with the result obtained with fine grained film used with lead screens (see Figure 5.1(c)) but the image processing has a substantial effect on the perceived image characteristics. To the eye, the image processed image appears substantially sharper than the one without processing, but the noise level (granularity) on the processed image is higher than that without processing. Thus, the effect of the image processing has been to improve the clarity of image detail (edges etc), at the expense of an increase in noise level. However, by varying the image processing parameters it is possible to obtain many different effects, with different trade-offs between noisy/granularity level and apparent image/edge sharpness.

(a)

(b)

Figure 5.5 Digital images obtained using computed radiography system 1 (technique 1

with Se 75) on a threaded small bore connector (OD 17 mm, WT 3.1 mm before introduction of screw thread) connected to 3” pipe (WT 7.6 mm) with ‘severe’ corrosion (mean wall loss 43%). (a) Computed radiography image without spatial image processing, (b) Computed radiography image after spatial image processing using one combination of processing parameters selected

to highlight edge detail. Results courtesy of Oceaneering OIS plc. (b) Computed radiography System 2

30

Page 38: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

Figure 5.6 shows examples of results obtained with a second computed radiography system, using Se 75 and technique 1 on a 3 inch main pipe specimen. A direct comparison can be made with Figure 5.2 which shows the corresponding results obtained with fine grain film with lead screen.

(a)

(b)

(c)

Figure 5.6 Digital images obtained using computed radiography system 2 (technique 1 with Se 75) on small bore connectors (OD 17 mm, WT 3.1 mm) connected to 3” pipe (WT 7.6 mm). (a) no corrosion, (b) ‘moderate’ corrosion (mean wall loss 28%), (c) ‘severe’ corrosion (mean wall loss 52%). For a comparison with the corresponding fine grain results, see Figure 5.2. Results

courtesy of SafeRad Ltd The results from the computed radiography system clearly show the moderate and severe levels of corrosion by both the reduced wall thickness in tangential mode and the increased image density in straight-through radiography mode. However, as with computed radiography system

31

Page 39: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

1, some loss of spatial resolution compared with fine grained film used with lead screens is apparent. 5.3 INSPECTION OF APPROXIMATELY UNIFORM CORROSION/EROSION

Detectability and sizing of approximately uniform corrosion/erosion is best achieved using the tangential radiography method by direct imaging of the resulting wall loss. Detectability is affected by the location of the wall loss, as follows. 5.3.1 Wall loss external to the main pipe

If the wall loss is in the section of the small bore connectors external to the main pipe wall, then the techniques 1-4 described in Section 4.2 are applicable, and detectability will not be affected by the diameter and wall thickness of the main pipe to which the small bore piping is attached. The HOIS2000 trials showed that all the source/detector media combinations described in this document allowed both the “moderate” (20-30% loss of wall) & “severe” (40-60%) levels of corrosion to be readily detected. The minimum detectable wall loss is therefore appreciably less than 20%, especially for the highest quality technique such as fine grain film used with lead screens. 5.3.2 Wall loss within the main pipe wall

Inspection of corrosion within the wall of the main pipe is affected by the significantly increased metal paths that need to be penetrated by the gamma-ray radiation. For metal paths of around 50 mm, both Ir 192 and Se 75 gave adequate penetration and hence detectability of wall loss would be similar to the values for external corrosion/erosion given above. Table 2.1 gives the maximum metal paths involved in the inspection of schedule 40 and 80 pipes of differing diameters. From this, it can be seen that metal paths of 50 mm or less are obtained for pipes of diameter 3 inch or less. For maximum metal paths of 100 mm, only marginal detection of the presence of corrosion/erosion within the wall of the main pipe was obtained with Ir 192 used with fine grain film and lead screens. No detection was demonstrated at such high metal paths using Se 75 and either fine grained film with lead screens or with the computed radiography systems. Thus, for maximum metal paths between 50 and 100 mm, detectability of corrosion/erosion is predicted to decrease relatively gradually with increasing metal path with Ir 192, but more rapidly for the less penetrating Se 75. Main pipes with maximum metal paths in this range are typically between 3 inch and 10 inch in diameter (see Table 2.1). For larger diameter pipes (>10 inch OD), neither of these isotopes would be capable of adequate penetration of the main wall. More penetrating isotopes sources such as Co 60 could then be used, but there are additional safety issues when using such sources.

32

Page 40: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

5.4 DETECTABILITY OF ISOLATED CORROSION PITS

Detection, sizing and positioning of isolated corrosion pits as opposed to generalised wall loss raises additional issues for radiographic inspection. Isolated corrosion pits around the circumference of the connector are readily detectable with radiography but cannot be correctly positioned and sized in the through-wall direction unless a large number of radiographs are taken at different circumferential angles using the tangential method. However, the geometry of the small bore connections makes it difficult with flexible film, and impossible with rigid cassettes, to position the detection medium in such a way as to make the tangential method possible at all positions around the circumference, apart from the detector positions described in this document, i.e. techniques 1-4 described in Section 4.2. Thus, detection of an isolated corrosion pit at an arbitrary circumferential location would generally be best achieved by the density difference produced on the radiograph in straight-though mode (see Figure 3.2). To find the shallowest pits, use of Se75 instead of Ir 192, would then be preferred to obtain higher contrast radiographs, provided the pitting is in sections of the small bore connector external to the main pipe. To measure the through-wall depth of a corrosion pit, a tangential radiographic image of the pit would still be needed. Detectability of small corrosion pits using radiography was not assessed in the HOIS2000 small bore connector trials, nor is there any published probability of detection (POD) information relevant to small bore connector inspection. However, some information on the smallest size of detectable corrosion pit can be estimated from published IQI information. The step/hole type of IQI indicator consists of a cylindrical hole having a height equal to its diameter, which is a reasonable approximation for the shape of a small corrosion pit. However, the shape of the pit will affect its detectability. Very narrow "worm-hole" type pits will be more difficult to detect than wider pits having the same depth. For Ir 192 and the lower energy Yb-169, Halmshaw (1995, p 185) gives values for attainable IQI sensitivity values in flat plate steel using fine grain film, which are shown here in Table 5.2. Table 5.2 Attainable IQI sensitivity values in flat plate steel for Ir 192 and Yb 169 gamma ray

sources and fine grain film with thin lead screens, taken from Halmshaw (1995). Steel thickness Source Step/Hole IQI (%) Hole diameter (mm) 6 Yb169 5.0 0.32 6 Ir 192 6.6 0.4 12 Yb169 3.3 0.4 12 Ir 192 4.1 0.5 25 Ir 192 2.6 0.63 40 Ir 192 2.0 0.8 50 Ir 192 2.0 1.0 For detection of corrosion pits in piping, the minimum steel thickness in the “straight-through” technique is twice the wall thickness, so to convert the figures for percentage sensitivity into an

33

Page 41: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

equivalent loss of (single) wall due to a corrosion pit would require multiplication by a factor of at least two. Thus, for example for a small bore pipe with a 3 mm wall thickness using Ir 192, the Step/Hole IQI sensitivity is 6.6%, from which it can be inferred that a corrosion pit producing a 13.2% loss of wall may just be detectable using fine grain film with thin lead screens. This assumes that the corrosion pit is ideally placed in the centre of the pipe image, on the radiation beam axis. For corrosions pits off-centre the metal path will be higher, and sensitivity will be reduced. The sensitivity achievable with Se 75 should be somewhat higher than that for Ir 192, as Se 75 generates radiation with a mean gamma-ray energy approximately mid-way between Ir 192 and Yb 169. Thus the corresponding IQI sensitivity for 6 mm of steel is likely to be c. 5.5%, which converts to a 11% minimum detectable loss of wall for an idealised corrosion pit in the centre of the pipe image. For pipes with larger wall thicknesses, note that the sensitivity when expressed in percentage terms improves. Thus for a pipe with 6 mm wall thickness, the corresponding minimum detectable wall loss for an isolated corrosion pit would be 8.8%, with the same assumptions as detailed above. In practice, however, detection of corrosion pits in pipes will be more difficult than detection of a step/hole IQI in a known location within a uniform plate, for the following main reasons: (a) With an IQI device, the inspector knows exactly where to look for the object of interest.

Isolated corrosion pits on the other hand could occur in any location within a large region of pipe material.

(b) With an IQI device on a flat plate, the density of the radiograph is almost constant over the

region of interest. With pipe inspection, the density of the radiograph changes appreciably with distance from the centre of the image of the pipe.

(c) Corrosion pits can be irregular and less well defined than a machined cylindrical hole In view of the above factors, more realistic conservative estimates for the minimum detectable depth of a corrosion pit would be 15 – 20% loss of wall for pipes with wall thicknesses in the range 3 - 6 mm, provided the pit is approximately centrally placed in the pipe image (not too close to the tangential view). Further investigation of this issue is recommended.

34

Page 42: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

6 SUMMARY OF RELEVANT SAFETY STANDARDS AND LEGISLATION

• The requirements of all relevant national and international safety standards relating to the use of ionising radiation must be complied with. In the UK, the Ionising Radiations Regulations 1999 (IRR 1999) are enforced by the Health & Safety Executive (HSE). These are legal requirements and include the construction and maintenance of radiation controlled areas, by means of appropriate barriers. Pre-planning of the inspection work to be carried out on a plant, to include both a risk assessment and a practical assessment of how the source container and shielding will be placed is also covered by this legislation.

• The safe transport of radioactive material is covered by IAEA regulations, the latest version

of which is TS-R-1 (ST-1, Revised). Individual countries have their own legislation covering this area.

• Gamma ray sources and their containers are covered by the standards ISO 2919: 1999 and

ISO 3999-1:2000, respectively. • The standard BS 5650:1978, ISO 3999-1977 concerning specification for apparatus for

gamma radiography is also still current.

7 MAIN RECOMMENDATIONS

The Sections presents a summary of the main recommendations contained in this document. Radiography methods • The tangential radiography method is recommended for the detection and through-wall

sizing of extended areas of corrosion, and should not generally be used for isolated corrosion pits, unless their circumferential location has already been established using for example the density difference method.

• The straight-through or density difference radiographic method is recommended for the

detection (but not through-wall sizing) of isolated corrosion pits, and can also be used for detection of extended areas of corrosion.

• Both the tangential and straight-through methods can be combined on a single radiograph of

a small bore pipe. Isotope sources • For the inspection of the sections of the small bore connectors external to the main pipe, the

two recommended isotope sources are Iridium 192 and Selenium 75. • Source selection should be made according to the criteria given in Section 3.1.1. • The source size for inspection of small bore piping should be chosen taking account of the

limits on geometric unsharpness given in Section 4.2. Typically source sizes for this application will be about 2 x 2mm (effective size for calculation of geometric unsharpness 2.3 mm).

35

Page 43: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

• Careful collimation of the sources is recommended to minimise unwanted radiation, and

reduce the effects of scatter on the radiographs. Wall thickness measurements • Radiography contractors should produce a written procedure detailing how wall thickness

measurements will be made in a consistent and accurate manner, particularly if this technique is used for condition monitoring of specific inspection points

Source to film distances • The source to film distance, SFD, should be set so that the geometric unsharpness in the

plane of the object is not more than 0.3 mm. A minimum SFD of 300 mm should be used. Exposure time reduction • For conventional radiography using fine grain film, exposures times should be chosen to

obtain a density of c. 3 in the centre of the small bore connection, so that the density of the tangential wall thickness area is not too low.

• Recommended measures to reduce exposure time include reduction of the object to film

distance, and hence SFD, by placing the detection medium in direct contact with the small bore connector (a flexible detection medium is needed if the junction with main pipe is to be inspected).

• The highest quality radiographic images are obtained with fine grain film used with thin

lead screens. Alternative detection media can be used to reduce exposure time, including (a) fine grain film with fluorometallic screens and (b) the reusable phosphor plates in computed (filmless) radiography systems, provided the reduction in image quality is acceptable for the application.

It is important to note that the above recommendations are based on trials which were completed under laboratory conditions inside an exposure compound or similar controlled and uncluttered environment. This made it straightforward to set-up the radiography equipment in such a way as to achieve safe radiation dose rates in a small controlled area, whilst using highly penetrating radioisotopes and the source to film distances (SFD) recommended in this document. The practical application of these recommendations under typical site conditions may need modification for particular circumstances. In-situ, local access to small bore connectors is often restricted, limiting the choices for the source position and shielding. The appropriate legislation requires the radiography contractor to conduct a prior risk assessment of the work and it is at this stage that a practical assessment should highlight potential difficulties so that solutions can be planned in advance.

36

Page 44: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

8 RECOMMENDATIONS FOR FURTHER WORK

Further experimental work is recommended to provide further information which could be incorporated into later versions of this recommended practice: • Quantify the sensitivity of radiographs of small bore piping using IQIs to compare the

values obtained with those given in EN 1435 for weld radiography. For the computed (filmless) systems, use of Duplex Wire IQIs which measure more directly the spatial resolution of the image should be investigated.

• Assess the detectability of isolated corrosion pit type defects in small bore piping

specimens, as a function of defect size/depth and circumferential location in the pipe in relation to the radiation beam axis direction.

9 ACKNOWLEDGEMENTS

This document has benefited from comments made on earlier drafts by Jim McNab of Oceaneering OIS plc, Malcolm Wass of SafeRad Ltd and those HOIS2000 members who participated in the Complex Geometry Working Group meeting in September 2002. Jim McNab and Malcolm Wass are also thanked for carrying out the trials which resulted in the example images. The assistance of BP Coryton with specimen manufacture is also gratefully acknowledged. Arild Dalheim, of Norsk Hydro, is thanked for supplying a number of weldolets. For the duration of this work, Raman Patel (HSE) acted as Project Champion and provided valuable advice and support throughout, as well as commenting on an earlier draft of this report.

10 REFERENCES

Burch, S F and Collett, N J (2002) “Evaluation trials of radiographic techniques for the rapid inspection of small bore connector components”, a report produced for HOIS2000, HOIS2000(02)R1. BS 5650:1978, ISO 3999-1977 Specification for apparatus for gamma radiography BS EN 1435 (1997) “Non-destructive examination of welds - Radiographic examination of welded joints”, European and British Standard. Halmshaw, R (1995) Industrial Radiology Theory and Practice Second Edition, Chapman & Hall International Atomic Energy Agency. Regulations for the Safe Transport of Radioactive Material, 1996 Edition (Revised), Safety Standards Series No. TS-R-1 (ST-1, Rev), IAEA, Vienna (2000). ISO2919 : 1999 Radiation protection -- Sealed radioactive sources -- General requirements and classification

37

Page 45: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

ISO3999-1: 2000 Radiation protection - apparatus for industrial gamma radiography - Part 1: Specifications for performance, design and tests. The Ionising Radiation Regulations 1999, Statutory Instruments 1999 No 3232, ISBN 0-11-085614-7, The Stationery Office, P.O. Box 276, London SW8 5DT (referred to in this document as IRR 1999)

38

Page 46: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

Printed and published by the Health and Safety ExecutiveC30 1/98

Printed and published by the Health and Safety ExecutiveC0.06 01/05

Page 47: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

RR 294

£10.00 9 78071 7 629398

ISBN 0-7176-2939-2

Page 48: RESEARCH REPORT 294 · 2019-12-05 · The tangential radiography method is recommended for the detection and through-wall sizing of extended areas of corrosion, and should not generally

Reco

mm

end

ed

pra

ctice fo

r the ra

pid

insp

ectio

n o

f small b

ore

connecto

rs usin

g ra

dio

gra

phy

HS

E BO

OK

S