rf measurement of t18 after high power test

17
RF measurement of T18 after High power test Jiaru Shi 27.07.2011

Upload: mendel

Post on 05-Jan-2016

37 views

Category:

Documents


0 download

DESCRIPTION

RF measurement of T18 after High power test. Jiaru Shi 27.07.2011. CERN built T18. Before high power testing. after high power testing. Faya Wang @ SLAC. Faya Wang @ SLAC. Before high power testing. After high power testing. Standing wave pattern  Reflection before last regular cell. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: RF measurement of T18 after High power test

RF measurement of T18 after High power test

Jiaru Shi27.07.2011

Page 2: RF measurement of T18 after High power test

Before high power testing

after high power testing

CERN built T18

Page 3: RF measurement of T18 after High power test

Faya Wang @ SLAC

Page 4: RF measurement of T18 after High power test

Faya Wang @ SLAC

Page 5: RF measurement of T18 after High power test

After high power testingBefore high power testing

Page 6: RF measurement of T18 after High power test

Standing wave patternReflection before last regular cell

0.02

0.04

0.06

30

210

60

240

90

270

120

300

150

330

180 0

after

before

Page 7: RF measurement of T18 after High power test

Detuning of cells(difference of required tuning)

0 5 10 15 20-3

-2

-1

0

1

2

3

4

5x 10

6

number of cells

df a

fter

hig

h po

wer

tes

ting

(Hz)

Not sure for input matching cell

Page 8: RF measurement of T18 after High power test

Amplitude Measurement of T18-SLAC #1 Before and After High Power Test

11421.7 MHz at 21.32°C, N2 Before high Power test

11421.87 MHz at 20.4°C, N2 After high power test

Juwen Wang @ SLAC

1350 hours

Page 9: RF measurement of T18 after High power test

11421.7 MHz at 21.32°C, N2 ore high Power test

11421.87 MHz at 20.4°C, N2 After high power test

Phase Measurement of T18-SLAC #1 Before and After High Power Test

Juwen Wang @ SLAC

Page 10: RF measurement of T18 after High power test

Amplitude Measurement of TD18-SLAC Before and After High Power Test

11424.5 MHz at 21.46°C, N2 Before high Power test

11424.56 MHz at 21.1°C, N2 After high power test

Juwen Wang @ SLAC

Page 11: RF measurement of T18 after High power test

Phase Measurement of TD18-SLAC Before and After High Power Test

16.5°

11424.5 MHz at 21.46°C, N2 ore high Power test

11424.56 MHz at 21.1°C, N2 After high power test

Select bead pulling frequencies based on the same measurement condition for both before and after high power test

Juwen Wang @ SLAC

Page 12: RF measurement of T18 after High power test

Amplitude Measurement of T18-SLAC #1 Before and After High Power Test

11424.1 MHz at 20.02°C, N2 Before high Power test

11424.15 MHz at 20.4°C, N2 After high power test

T24Juwen Wang @ SLAC

Page 13: RF measurement of T18 after High power test

Phase Measurement of T24-SLAC Before and After 800 Hours High Power Test

Select bead pulling frequencies based on the measurement condition to get 2π/3 phase advance for both before and after high power test

11424.1 MHz at 21.1°C, N2 After high Power test

11424.1 MHz at 21.2°C, N2 Before high power test

Juwen Wang @ SLAC

Page 14: RF measurement of T18 after High power test

T18 SLAC N1 TD18 SLAC T24 SLAC T18 CERN N2

Measured at SLAC SLAC SLAC CERN

Output matching

Standing Wave(SWR)

1.06 1.2 1.05 1.1

(reflection) 0.03, -30dB 0.1,-20dB 0.025, -32dB 0.05, -26dB

Estimate df if only one cell detuned

2MHz 7MHz 2.5MHz 3MHz

from standing wave pattern

N-1 cell-F

N-1 cell-F

Output cell+F

N-1 cell -F

Regular cells

Total phase shift -16 deg +6 deg

~df +1 MHz -0.3 MHz

Page 15: RF measurement of T18 after High power test

TD18 Chamfer100 um -1MHz

Chamfer TD18

20.00 40.00 60.00 80.00 100.00r_chamfer [um]

-0.13

0.00

0.13

0.25

0.38

0.50

0.63

0.75

(re

(Mo

de

(1))

-11

42

5M

Hz)

/1M

Hz

Ansoft LLC f0XY Plot 2 ANSOFT

Curve Info

(re(Mode(1))-11425MHz)/1MHzSetup1 : LastAdaptive

Page 16: RF measurement of T18 after High power test

T18 chamfer100 um -0.5MHz

10.00 30.00 50.00 70.00 90.00r_chamfer [um]

0.05

0.15

0.25

0.35

0.45

0.50

(re

(Mo

de

(1))

-11

42

4M

Hz)

/1M

Hz

Ansoft LLC cell_1XY Plot 1 ANSOFT

Curve Info

(re(Mode(1))-11424MHz)/1MHzSetup1 : LastAdaptive

Page 17: RF measurement of T18 after High power test

TD18 Iris ellipse aspect ratio 1.1 to 1.2frequency + 8.2MHz

1.100 1.120 1.140 1.160 1.180 1.200e

-6.00

-4.75

-3.50

-2.25

-1.00

0.25

1.50

2.75

(re

(Mo

de

(1))

-11

42

4M

Hz)

/1M

Hz

Ansoft LLC f0XY Plot 2 ANSOFT

Curve Info

(re(Mode(1))-11424MHz)/1MHzSetup1 : LastAdaptive

0 0.5 1

3

3.5

4

4.5

z (mm)

r (m

m)

1.1

1.2

aspect ratio

+1MHz ~ removing 0.12mm3 copper at the iris