rhino range by thor building 2016

83
by THOR BUILDING PRODUCTS Residential & Commercial Insulation www.thorbuilding.com.au RHINO is a trusted brand in the building industry known for Quality Products, Service & Support. Proudly Owned & Manufactured in Australia for 15 years

Upload: thorbuilding

Post on 26-Jul-2016

225 views

Category:

Documents


2 download

DESCRIPTION

 

TRANSCRIPT

Page 1: rhino range by thor building 2016

by THOR BUILDING PRODUCTS

Residential & Commercial Insulationwww.thorbuilding.com.au

RHINO is a trusted brand in the building industry known for Quality Products, Service & Support.Proudly Owned & Manufactured in Australia for 15 years

Page 2: rhino range by thor building 2016

Thor Building Products Pty Ltd

HEAD OFFICE293 Earnshaw Rd Northgate QLD 4013

MANUFACTURING PLANT32 Lysaght St Acacia Ridge QLD 4110

T: 1300 880 828 F: 07 3219 6833E: [email protected]: www.thorbuilding.com.au

ABN 12 088 560 392 HIA 8 6 5 4 8 3

Page 3: rhino range by thor building 2016

RHINO is a trusted brand in the building industry known for Quality Products, Service & Support.Proudly Owned & Manufactured in Australia for 15 years

by THOR BUILDING PRODUCTS

Section 1GLASSWOOL

Rhino glasswool batt insulation range

Section 2BLANKET

Rhino blanket range

Section 3POLYESTER

Rhino white polyester batt range

Section 4CELL RANGE

Rhino cell range

Section 5FOAM

Rhino foam range

Section 6WRAP & FOIL

Rhino wrap reflective foil range

Section 7PIR BOARD

Rhino PIR board range

Section 8PIPE LAGGING

Rhino pipe acoustic lagging

Section 9ROCKWOOL

Other wall & surface insulation products

Section 10ACCESSORIES

Page 4: rhino range by thor building 2016

1

RHINO BATTSFOR THERMAL APPLICATIONS

Product Code R-Value (m2k/w)

Thickness (mm)

Batt size (mm)

Batts/pack Area/pack (m2)

Coverage/pack (m2)

RBatt-R1.5-430 1.5 65 1160 x 430 24 12.0 13.6

RBatt-R1.5-580 1160 x 580 24 16.2 18.2

RBatt-R2.0-430 2.0 90 1160 x 580 24 12.0 13.6

RBatt-R2.0-580 1160 x 430 24 16.2 18.2

RBatt-R2.0HD-430 2.0HD* 75 1160 x 430 12 6.0 6.8

RBatt-R2.0HD-580 1160 x 580 12 8.1 9.1

RBatt-R2.5-HD430 2.5HD* 90 1160 x 430 12 6.0 6.8

RBatt-R2.5-HD580 1160 x 600 12 8.6 9.7

Product Code R-Value (m2k/w)

Thickness (mm)

Batt size (mm)

Batts/pack Area/pack (m2)

Coverage/pack (m2)

RBatt-R2.5-430 2.5 130 1160 x 430 16 8.0 9.0

RBatt-R2.5-580 1160x 580 16 10.8 12.2

RBatt-R3.0-430 3.0 155 1160x 580 16 8.0 9.0

RBatt-R3.0-580 1160x 430 16 10.8 12.2

RBatt-R3.5-430 3.5 175 1160x 430 16 8.0 9.0

RBatt-R3.5-580 1160x 580 10 6.7 7.6

RBatt-R4.0-430 4.0 195 1160x 430 10 5.0 5.6

RBatt-R4.0-580 1160x 580 10 6.7 7.6

RBatt-R5.0-430 5.0 215 1160x 430 8 4.0 4.5

RBatt-R5.0-580 1160x 580 8 5.4 6.1

RBatt-R6.0-430 6.0 250 1160x 430 6 3.0 3.4

RBatt-R6.0-580 1160x 580 6 4.0 4.5

WALLThe comprehensive range of sizes and R-values available ensures there is an effi cient and effective RHINO Batts insulation solution available for any application. RHINO Batts insulation for wall applications are stiffened to fi t snugly between standard spacing wall studs – both timber and steel – without sagging and should be installed at the time of construction before fi xing internal lining

CEILINGRHINO Batts glass wool products are manufactured from FBS-1 Glass wool Bio- Soluble Insulation®. FBS-1 Glass wool Bio-Soluble Insulation® is not classifi ed as hazardous according to the criteria of the Australian Safety and Compensation Council (formerly NOHSC), Approved Criteria for Classifying Hazardous Substances (NOHSC: 1008) 3rd Edition. RHINO Batts glass wool is classifi ed as safe to use refer to our MSDS. ®

MOISTURE ABSORPTIONIn the event of RHINO Batts insulation becoming wet, they should be dried prior to installation to obtain maximum performance and prevent damage to other building elements. RHINO Batts insulation absorb less than 0.2% moisture by volume when exposed to environmental conditions of 50°C and 95% relative humidity for four days.

AS1530.1 TEST FOR COMBUSTIBILITY OF MATERIALSTesting conducted by CSIRO in accordance with AS1530 Part 1 concluded that RHINO Batts insulation are non-combustible. The Building Code of Australia (BCA) deemed to satisfy provisions require walls important to the structural integrity of commercial buildings to be constructed wholly of materials that are non-combustible. Fire rated (FRL) walls between tenancies and common walls of multi-level apartment buildings also must be constructed wholly of materials that are non- combustible. The BCA states that if materials used in an assembly contain combustible components, then the assembly is combustible. Incorporating non-combustible RHINO Batts insulation into wall systems allows builders to gain acoustic and thermal benefi ts while still complying with the BCA requirement to maintain structural integrity and for minimising risk to occupants from smoke inhalation and fi re in Class 2 to 9 buildings.

• Minimum Order QTY may apply (HD= High Density)

PRODUCT DESCRIPTION

RHINO Batts are made from lightweight, fl exible and resilient glasswool, specially designed for the thermal insulation of ceilings and walls in

domestic and commercial buildings. They have the

added benefi t of being an effective sound absorber and so contribute to both the thermal and acoustic

comfort of building occupants.

SPECIFICATION NOTESWhen specifying state

the following:• Product name -

RHINO Batts• Material R-value

required• Joist or stud spacing• Area involved.

R H I N O B AT T SFOR THERMAL APPL ICATIONS

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 5: rhino range by thor building 2016

2

RHINO BATTSFOR THERMAL APPLICATIONS

AS1530.3 EARLY FIRE HAZARD PROPERTIES OF MATERIALSRHINO Batts insulation exhibit the following characteristics when tested in accordance with AS1530 Part 3: Ignitability Index 0 Spread of Flame Index 0 Heat Evolved Index 0 Smoke Developed Index 0-1

ALKALINITYWhen tested in accordance with British Standard 3958, RHINO Batts glasswool products are slightly alkaline pH9 (neutral is pH7). They will not promote or accelerate the corrosion of steel or galvanised steel studs provided they are protected from external contamination.

MAXIMUM SERVICE TEMPERATURERHINO Batts insulation have a maximum service temperature of 340°C.

PRODUCT DESCRIPTION

RHINO Batts are made from lightweight, fl exible and resilient glasswool, specially designed for the thermal insulation of ceilings and walls in

domestic and commercial buildings. They have the

added benefi t of being an effective sound absorber and so contribute to both the thermal and acoustic

comfort of building occupants.

SPECIFICATION NOTESWhen specifying state

the following:• Product name -

RHINO Batts• Material R-value

required• Joist or stud spacing• Area involved.

R H I N O B AT T SFOR THERMAL APPL ICATIONS

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 6: rhino range by thor building 2016

3

RHINO PARTITION BATTS COMMERCIAL ACOUSTIC & THERMAL INSULATION

Material R-value Nominal thickness Batt size (mm) Pieces/pack Area/pack m2 Product code

RHINO Partition 12 Insulation

R1.2 50 1200 x 450 32 17.3 RPBatt-50-11-1245

2700 x 450 24 29.2 RPBatt-50-11-2745

1200 x 600 32 23.1 RPBatt-50-11-1260

2700 x 600 16 25.9 RPBatt-50-11-2760

R1.8 75 1200 x 450 16 8.6 RPBatt-75-11-1245

2700 x 450 24 29.2 RPBatt-75-11-2745

1200 x 600 16 11.5 RPBatt-75-11-1260

2700 x 600 16 25.9 RPBatt-75-11-2760

R2.1 90 1200 x 450 16 8.6 RPBatt-90-11-1245

2700 x 450 24 29.2 RPBatt-90-11-2745

1200 x 600 16 11.5 RPBatt-90-11-1260

2700 x 600 16 25.9 RPBatt-90-11-2760

RHINO Partition 14 InsulationR1.3 50 1200 x 450 24 13.0 RPBatt-50-14-1245

2700 x 450 24 29.2 RPBatt-50-14-2745

1200 x 600 24 17.3 RPBatt-50-14-1260

2700 x 600 16 25.9 RPBatt-50-14-2760

R1.9 75 1200 x 450 16 8.6 RPBatt-75-14-1245

2700 x 450 18 21.9 RPBatt-75-14-2745

1200 x 600 16 11.5 RPBatt-75-14-1260

2700 x 600 12 19.4 RPBatt-75-14-2760

R2.2 90 1200 x 450 14 7.6 RPBatt-90-14-1245

2700 x 450 15 18.2 RPBatt-90-14-2745

1200 x 600 10 7.2 RPBatt-90-14-1260

2700 x 600 10 16.2 RPBatt-90-14-2760

RHINO Partition 24 InsulationR0.7 25 2700 x 600 20 32.40 RPBatt-25-24-2760

R1.1 38 2700 x 600 12 19.40 RPBatt-38-24-2760

R1.4 50 1200 x 450 12 6.50 RPBatt-50-24-1245

1200 x 600 12 8.60 RPBatt-50-24-1260

2700 x 600 12 19.40 RPBatt-50-24-2760

R1.8 64 2700 x 600 10 16.20 RPBatt-64-24-2760

R2.1 75 1200 x 450 10 5.40 RPBatt-75-24-1245

1200 x 600 10 7.20 RPBatt-75-24-1260

R2.5 90 1200 x 450 8 4.30 RPBatt-90-24-1245

1200 x 600 8 5.80 RPBatt-90-24-1260

R2.8 100 1200 x 450 6 3.20 RPBatt-100-24-1245

1200 x 600 6 4.30 RPBatt-100-24-1260

RHINO Partition 32 InsulationR1.5 50 1200 x 450 12 6.5 RPBatt-50-32-1245

1200 x 600 12 8.6 RPBatt-50-32-1260

R2.2 75 1200 x 450 10 5.4 RPBatt-75-32-1245

1200 x 600 10 7.2 RPBatt-75-32-1260

R2.7 90 1200 x 450 8 4.3 RPBatt-90-32-1245

1200 x 600 8 5.8 RPBatt-90-32-1260

R3.0 100 1200 x 450 6 3.2 RPBatt-100-32-1245

1200 x 600 6 4.3 RPBatt-100-32-1260

RHINO PARTITION BATTS FEATURES A SOFT FEEL FOR MORE COMFORTABLE HANDLING

PRODUCT DESCRIPTION AND TYPICAL APPLICATIONSRHINO Partition Batts is a lightweight, glasswool product specially designed to be freestanding for quick installation in steel stud framing for multi-residential and commercial steel frame buildings. All products are designed to give assurance of effective sound absorption and to reduce noise transfer between rooms. Whilst effectively providing solutions to ‘problem’ acoustic applications, RHINO Partition Batts also provides a range of thermal values making the products suitable for insulating the external walls of a building envelope there by increasing the comfort levels of building occupants.

PRODUCT DESCRIPTION

RHINO Partition Batts are a lightweight, glasswool

product specially designed to be free standing for

quick installation in steel stud framing for multi-

residential and commercial steel frame buildings.

SPECIFICATION NOTESWhen specifying state

the following:• Product name i.e. RHINO

Partition Batts followed by the relevant density i.e. RHINO Partition 11, 14, 24 or 32.

• Material R-value required and/or thickness required.

• Joist or stud spacing.• Area involved.

R H I N OP A R T I T I O N

B AT T STHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 7: rhino range by thor building 2016

4

RHINO PARTITION BATTS COMMERCIAL ACOUSTIC & THERMAL INSULATION

ACOUSTIC PERFORMANCE PREDICTIONS

1. 7.5mm (R0.1) lightweight cladding2. Unventilated 35mm airspace3. Refl ective insulation material4. 35mm battens5. 90mm RHINO Partition 24 insulation6. 92mm steel stud7. 10mm plasterboard

1. Steel cladding2. Unventilated 35mm airspace3. Refl ective insulation material4. 35mm battens5. 90mm RHINO Partition 32 insulation6. 92mm steel stud7. 10mm plasterboard

1. 10mm plasterboard2. 92mm steel stud3. 90mm RHINO Partition 14 insulation4. 10mm plasterboard

Sound Reduction Index (Rw) 48The Rw estimated tolerance is ± 3dB

Sound Reduction Index (Rw) 41The Rw estimated tolerance is ± 3dB

Sound Reduction Index (Rw) 42The Rw estimated tolerance is ± 3dB

FIBRE CEMENT CLAD STEEL STUD WALL SYSTEM

METAL CLAD STEEL STUD WALL SYSTEM

INTERNAL STEEL FRAME PARTITION WALL

1. 2. 3. 4. 5. 6. 7.

PRODUCT DESCRIPTION

RHINO Partition Batts are a lightweight, glasswool

product specially designed to be free standing for

quick installation in steel stud framing for multi-

residential and commercial steel frame buildings.

SPECIFICATION NOTESWhen specifying state

the following:• Product name i.e. RHINO

Partition Batts followed by the relevant density i.e. RHINO Partition 11, 14, 24 or 32.

• Material R-value required and/or thickness required.

• Joist or stud spacing.• Area involved.

R H I N OP A R T I T I O N

B AT T STHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 8: rhino range by thor building 2016

5

RHINO PARTITION BATTS COMMERCIAL ACOUSTIC & THERMAL INSULATION

TOOLS REQUIRED

BRICK VENEER

FIBRE CEMENT OR WEATHERBOARD CLADDING

INTERNAL PARTITION WALLS

CAVITY BRICK WALLS (DOUBLE BRICK)

BEFORE YOU COMMENCE

INSTALLATION GUIDELINES

Turn off the power at the fuse box before commencing the installation. Ensure you place a warning tag to prevent power being restored prior to completion of the install. Be aware that your electrical appliances will not be operatinal during this time. Use only RHINO Partition insulation, recommended according to the type of thickness of the stud.

• Curved blade knife with plastic handle (non-conductive handle)

• For high density batts a serrated knife with a plastic handle is recommended

• Knife holster to quickly access the knife

• Friction fi t the insulation into the wall frames ensuring there are no gaps between the insulation and studs or noggins.

• It is important that the insulation is secured so it cannot fall into the cavity or come in contact with the outer brickwork allowing moisture to pass from the exterior wall to the internal lining.

• Wall wrap or long lasting string/twine should be fi xed across the exterior face of the frame before installing the insulation from the inside.

• Where string/twine is used, twine should be fi xed between each set of studs from the top to the bottom, running parallel with the studs. Where two lengths are used they should be evenly spaced.

• Ensure that the batts do not protrude past the stud and fi t snugly including where insulation is around water pipes or other rigid obstructions in the wall.

• A breather (low vapour barrier) wall wrap or building paper must be used so as not to cause moisture build up.

• Butt the insulation closely together to ensure there are no gaps left at joints.• Offcuts may be used to fi ll small spaces to ensure complete coverage.

• Friction fi t the Insulation into the wall frames ensuring there are no gaps between the insulation and studs or noggins.

• Ensure that the batts do not protrude past the stud and fi t snugly.

• RHINO Partition insulation is not recommended for use in cavity brick construction.

• Industrial strength ladder• Tape measure• Safety eye wear• Safety shoes

For comprehensive details, please refer to Australian Standard 3999.CAUTION: Electric cables and equipment partially or completely surrounded with bulk thermal insulation may overheat and fail. This

applies to wiring installed prior to 1989. Refer to AS39991992 including Amendment 1: Section 2.6 for details.Cabling post 1989: continuous electrical cabling (240 volts) cannot be fully surrounded by the insulation for a length greater than 300mm.

In runs greater than 300mm, the electrical wiring must be touching a timber stud or the plaster lining.

Green Star compliant: RHINO Partition Insulation does not use Ozone Depleting Potential (ODP) substances in the manufacture or composition of its FBS-1 Glass Wool Bio-Soluble Insulation ® and Sisalation® refl ective foil products using insulation with an ODP of zero

will accrue one Green Star point under the InsulantODP Credit for eligible Green Star projects.

The use of these RHINO Partition Insulation products guarantees the use of ODP free insulation while also ensuring that no harmful levels of Volatile Organic Compounds (VOCs) are released. This allows the incorporation of environmentally preferable insulation whilst also

maintaining indoor air quality..

PRODUCT DESCRIPTION

RHINO Partition Batts are a lightweight, glasswool

product specially designed to be free standing for

quick installation in steel stud framing for multi-

residential and commercial steel frame buildings.

SPECIFICATION NOTESWhen specifying state

the following:• Product name i.e. RHINO

Partition Batts followed by the relevant density i.e. RHINO Partition 11, 14, 24 or 32.

• Material R-value required and/or thickness required.

• Joist or stud spacing.• Area involved.

R H I N OP A R T I T I O N

B AT T STHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 9: rhino range by thor building 2016

6

RHINO PARTITION BATTS COMMERCIAL ACOUSTIC & THERMAL INSULATION

AS1530.1-1994 TEST FOR COMBUSTIBILITYOF MATERIALSTesting conducted by CSIRO in accordance with AS1530.1 concluded that all 11-32kg/m3 RHINO Partition insulation products are non-combustible.

The National Construction Code (NCC) demmed to satisfy provisions require walls important to the structural integrity of commercial buildings to be constructed wholly of materials that are non-combustible. Fire rated walls between tenancies and common walls of multi-level apartment buildings must also be constructed wholly of materials that are non-combustible. The NCC states that if materials used in an assembly contain combustible components, then the assembly is combustible. Therefore incorporating non-combustible RHINO Partition insulation into wall systems allows users to obtain the products thermal and acoustic benefi ts whilst complying with the NCC requirement to maintain a buildings structural integrity.

RHINO Partition insulation exhibits the following characteristics when tested in accordance with AS1530.3.

In the event of RHINO Partition Batts becoming wet, it should be dried prior to installation to obtain maximum performance and prevent damage to other building elements. RHINO Partition insulation absorbs less than 0.2% moisture by volume when exposed to environmental conditions of 50˚C and 95%r elative humidity for four days.

When tested in accordance with British Standard 3958, Fletcher Insulation™ glasswool products are slightly alkaline ph9 (neutral is ph7). They will not promote or accelerate the corrosion of steel or galvanised steel studs provided they are protected from external contamination.

RHINO Partition Batts have a maximum service temperature of 340°C.

AS/NZS 1530.3-1999 EARLY FIRE HAZARD PROPERTIES OF MATERIALS

MOISTURE ABSORPTION

ALKALINITY

MAXIMUM SERVICE TEMPERATURE

Ignitability Index 0

Spread of Flame Index 0

Heat Evolved Index 0

Smoke Developed Index 0-1

PRODUCT DESCRIPTION

RHINO Partition Batts are a lightweight, glasswool

product specially designed to be free standing for

quick installation in steel stud framing for multi-

residential and commercial steel frame buildings.

SPECIFICATION NOTESWhen specifying state

the following:• Product name i.e. RHINO

Partition Batts followed by the relevant density i.e. RHINO Partition 11, 14, 24 or 32.

• Material R-value required and/or thickness required.

• Joist or stud spacing.• Area involved.

R H I N OP A R T I T I O N

B AT T STHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 10: rhino range by thor building 2016

7

RHINO BLANKET

d Excellent thermal & acoustic insulation.

d Can be used with timber & metal frame.

d Superior fi nished aesthetics. d Cost-effective. d Non-combustible blanket fi bres.

Product Code Thickness (mm) R-Value (m2K/W) Dimensions* (mm) Rolls/pack m2/pack

RB-R1.3-55 55 1.3 1200 x 15000 1 18

RB-R1.5-60 60 1.5 1200 x 15000 1 18

RB-R1.8-75 75 1.8 1200 x 15000 1 18

RB-R2.3-100 100 2.3 1200 x 10000 1 12

RB-R2.5-100 100 2.5 1200 x 10000 1 12

RB-R3.0-130 130 3.0 1200 x 10000 1 12

RB-R3.2-130 130 3.2 1200 x 10000 1 12

RB-R3.6-130 130 3.6 1200 x 6500 1 7.8

Product Code Thickness (mm) R-Value (m2K/W) Dimensions* (mm) Rolls/pack m2/pack

URB-R1.3-36 55 1.3 1200 x 30000 1 36.00

URB-R1.5-36 60 1.5 1200 x 30000 1 36.00

URB-R1.8-30 75 1.8 1200 x 25000 1 30.00

URB-R2.3-18 100 2.3 1200 x 15000 1 18.00

URB-R2.5-18 100 2.5 1200 x 15000 1 18.00

URB-R3.0-12 130 3.0 1200 x 10000 1 12.00

URB-R3.2-12 130 3.2 1200 x 10000 1 12.00

URB-R3.6-78 130 3.6 1200 x 6500 1 7.8

FOIL FACED

UNFACED

THERMAL INSULATION WITH CONDENSATION CONTROLRhino Blanket combines the thermal effi ciency of spun glass fi bre with a laminate of refl ective foil which not only further enhances the thermal effi ciency of the system but also serves to act as a dust and moisture barrier.

DESCRIPTION - Rhino Blanket is intended for both thermal and acoustical applications. It is made from highly resilient, inorganic glass fi bres.

SPECIFICATION COMPLIANCE - AS/NZS 4859.1: 2002 Materials used in the Thermal Insulation of Buildings and complies with the Building Code of Australia (BCA) requirements.

BIO-SOLUBILITY - Rhino Blanket rolls are manufactured from bio-soluble fi bres. Bio-soluble fi bres have been extensively researched and shown to pose no long term health risk.

APPLICATION - Designed for application under metal, fi bre cement, and concrete roof cladding Rhino Blanket eliminates the problems associated with condensation build up on the underside of the roof cladding. The refl ective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding.

Rhino Blanket also performs as an acoustic insulative barrier. It reduces noise from outside the home, such as rain and from within the home by absorbing reverberant noise. Rhino Blanket’s bulk insulation blanket is made from non-combustible fi bres and meets the BAL requirement for metal clad roofs in bushfi re areas.

FACING OPTIONS - The Duty Rating, Colour and Material Finish used to face Rhino Blanket can be varied to suit your application. Details upon request.

d TRADE preferred d Highly resilient insulation d Consistent quality d AS/NZS 4859.1:2002 d Bio-soluble d BCA Compliant d low VOC-emitting

* Cut to size available on request

PERFORMANCE

Thermal ConductivityASTM C 518

AS/NZS 4859.1: 2002

Thermal ResistanceASTM C 653

AS/NZS 4859.1: 2002

TECHNICAL DATA

Water Vapor Absorption(ASTM C 1104)

Less than 5% by weight

Corrosion Resistance(ASTM C 665)

No greater than sterile cotton

Microbial Growth (ASTM C 1338)

Does not support microbial growth

Fire Resistance(ASTM C 136)

R H I N O B LA N K E TTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 11: rhino range by thor building 2016

8

RHINO BLANKET FACING (HEAVY & EXTRA HEAVY DUTY)

d Satisfy BCA specifi cations and requirements for Refl ective Foil Laminates. d Complies with the specifi cations and requirements of AS/NZS 4200.1 for

“Pliable Building Membranes” which is a manual recognised by the BCA Part 3.5 Roof and Cladding.

d Low Flammability Index in accordance with AS 1530.2 ≤ 5 d Satisfy BCA Part 3.7.1 Fire Hazard Properties. d Satisfy Health and Safety Regulations.

APPLICATIONDesigned for application under metal, fi bre cement, and concrete roof cladding Thor’s Blanket Facing eliminates the problems associated with condensation build up on the underside of the roof cladding. The refl ective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding.

NOTE - Use in cold temperature climates (daytime <5oC) requires roof to be well ventilatedand moist air from within the dwelling to be exhausted out into the atmosphere.

FACING OPTIONS - The Duty Rating, Colour and Material Finish of the blanket facing can be varied to suit your application.

Colour Gloss White Gloss Silver-Grey Matt Dark Blue

Duty Extra Heavy Heavy HeavyWidth 1350 1350 1350

Residential & Commercial Insulation d d d

Vapour barrier High High High

Emittance Refl ective Refl ective Refl ective

Water barrier High High High

Flammability Index Low (≤5) Low (≤5) Low (≤5)

UV treated non refl ective face (not direct sunlight) d d d

Tensile Strength Machine Direction (kN/m) min 13.0 min 12.5 min 12.5

Tensile Strength Lateral Direction (kN/m) min 10.5 min 7.5 min 7.5

Edge Tear Resistance Machine Direction (N) min 90 min 80 min 80

Edge Tear Resistance Lateral Directions (N) min 90 min 80 min 80

Water Vapour Transmission Rate (Ng/Ns) max 2 max 2 max 2

Emittance of Refl ective Face max 0.05 max 0.05 max 0.05

PRODUCT INFORMATION

Thor’s Blanket Facing is made with a high strength

polywoven fabric facing which is applied to a

glasswool blanket whilstother products commonly

use a double sided foil with fi bre mesh for the facing.

The polywoven fabric provides the additional

benefi ts of:

d Outstanding tensile and tear strength.

d Unrolls more easily right the way to the end of the roll.

d An excellent visible surface fi nish.

R H I N O BLANKET F A C I N GTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 12: rhino range by thor building 2016

9

RHINO WHITE WALL & CEILING BATTSfor thermal applications

Product Code Product Description

Wall BattsWRBatt-R1.0-430 R1.0 Rhino White Poly Batt 75mm x 1160mm x 430mm

WRBatt-R1.0-580 R1.0 Rhino White Poly Batt 75mm x 1160mm x 580mm

WRBatt-R1.5-430 R1.5 Rhino White Poly Batt 90mm x 1160mm x 430mm

WRBatt-R1.5-580 R1.5 Rhino White Poly Batt 90mm x 1160mm x 580mm

WRBatt-R2.0HD-430 R2.0 Rhino White Poly Batt 90mm x 1160mm x 430mm

WRBatt-R2.0HD-580 R2.0 Rhino White Poly Batt 90mm x 1160mm x 580mm

WRBatt-R2.5HD-430 R2.5 Rhino White Poly Batt 90mm x 1160mm x 430mm

WRBatt-R2.5HD-580 R2.5 Rhino White Poly Batt 90mm x 1160mm x 580mm

Ceiling BattsWRBatt-R2.0-430 R2.0 Rhino White Poly Batt 120mm x 1160mm x 430mm

WRBatt-R2.0-580 R2.0 Rhino White Poly Batt 120mm x 1160mm x 580mm

WRBatt-R2.5-430 R2.5 Rhino White Poly Batt 165mm x 1160mm x 430mm

WRBatt-R2.5-580 R2.5 Rhino White Poly Batt 165mm x 1160mm x 430mm

WRBatt-R3.0-430 R3.0 Rhino White Poly Batt 18Smm x 1160mm x 430mm

WRBatt-R3.0-580 R3.0 Rhino White Poly Batt 185mm x 1160mm x 430mm

WRBatt-R3.5-430 R3.5 Rhino White Poly Batt 200mm x 1160mm x 430mm

WRBatt-R3.5-580 R3.5 Rhino White Poly Batt 200mm x 1160mm x 430mm

WRBatt-R4.0-430 R4.0 Rhino White Poly Batt 210mm x 1160mm x 430mm

WRBatt-R4.0-580 R4.0 Rhino White Poly Batt 210mm x 1160mm x 430mm

WRBatt-R4.5-430 R4.5 Rhino White Poly Batt 210mm x 1160mm x 430mm

WRBatt-R4.5-580 R4.5 Rhino White Poly Batt 210mm x 1160mm x 430mm

APPLICATIONSRHINO WHITE WALL & CEILING BAITS are designed for the thermal insulation of residential and com-mercial buildings. RHINO WHITE WALL & CEILING BAITS can be used in ceilings, internal and external walls and mid-fl oor cavities. To ensure Building Code compliance Thor Building Products recommends that Architects and building designers consult the relevant Australian Standards before specifying thermal insulation products.

BUILDING REGULATIONSRHINO WHITE WALL & CEILING BATTS will support and assist in meeting the following provisions of the BCA: BCA Volume One- Class 2-9 Buildings, Section J- Energy Effi ciency: Performance requirement JP1 BCA Volume One - Class 2-3 and 9c Buildings Section F - Health and Amenity: Sound Transmission and Insulation. Performance requirement FP5.1, FP5.2, FP5.4 and FP 5.5. BCA Volume Two - Class 1 and Class 10 Buildings Part 2.6 -Energy Effi ciency: Performance requirement P2.6.1 Part 3.8.6- Health and Amenity, Sound Insulation: Performance requirements P2.4.6

TECHNICALAcoustic Performance: RHINO WHITE WALL & CEILING BATTS will assist sound reduction by reducing the resonating noise inside the construction cavity. Typical improvement in sound transmission loss through walls with the use of® R2.0 Wall insulation is an increase of 5-6 Rw points. For information and assistance on Thermal and Acoustic design please contact your Representative.

HAZARDOUS BUILDING MATERIALS

d RHINO WHITE Polyester is non hazardous.

VOC EMISSION SAFE

d VOC concentration: 0.01 mg/m3 (7 days) d GECA/GreenGuard Limit: 0.25 mg/m3 (7 days) d Cetec Pty Ltd (Report:RCV080408}

DurabilityRHINO WHITE WALL & CEILING BATTS have a 50 Year Durability Warranty. RHINO WHITE BATTS when installed in accordance with the manufacturers instructions will satisfy the 50 year durability criteria for minimum design life as set out in the ABCB guidance document Durability in Buildings 2006 (Section 2.4).

PRODUCT DESCRIPTION

Our RHINO WHITE WALL & CEILING BATTS are

100% polyester thermal insulation segments pre-cut to fi t common timber framed walls, ceilings and mid-fl oor joist spacings.

R H I N O W H I T EWALL & CEILINGB A T T STHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 13: rhino range by thor building 2016

10

RHINO WHITE WALL & CEILING BATTSfor thermal applications

MoistureRHINO WHITE WALL & CEILING BATTS are not affected by moisture. Exposure to an atmosphere of 50oC at 90% relative humidity for four days showed moisture absorption by weight of less than 0.03%.

Non Flammable RHINO WHITE is classifi ed non -fl ammable.

Fire ratings: ISO 970S: 1993 Australian Group Number: Group

SMOGRA: less than 100m /sTest Number: 7-584608-CV

AS1S30.3lgnitability Index (0 -20) 0Heat Evolved Index (0-10) 0Spread of Flame Index (0-10) 0Smoke Developed Index (0-10) 3APL Report 98055

InstallationThor Building Products recommends that all thermal and acoustic insulation be installed in accordance with the manufacturers instructions (included on each RHINO WHITE WALL & CEILING BATTS) and AS 3999:1992 Thermal Insulation of Dwellings - Bulk insulation, installation requirements.

MSDSMaterial Safety Data Sheets (MSDS) are available on request from your Thor Representative or by visiting our website:www.thor building.com.au

Specifi cation & SubstitutionThor specifi cation documents can be downloaded from our website (www.thorbuilding.com.au). Substitution of any products should not be accepted and we recommend this be made clear in all specifi cation and tender documents.

Take Back ProgrammeRHINO WHITE WALL & CEILING BATTS are recyclable. We will gladly recycle used, uncontaminated RHINO® insulation to help keep it out of landfi ll. For more information on recycling THOR BUILDING PRODUCTS® contact on freephone 1300 880 828.

ISO StandardsTHOR BUILDING PRODUCTS is committed to Quality and Environmental best practice through our ISO 9001 & ISO 14001 certifi ed Quality and Environmental Management Systems .

IEC 60695-11-5 (Downlight Fire Test Standard)RHINO WHITE Polyester has been tested and certifi ed non-fl ammable and complies with the requirements of IEC 60695-11-5. Certifi cates available from our website. Non Corrosive: RHINO WHITE polyester is pH7.8 (pH7 is neutral) Non Toxic, Non Allergenic, Non Irritant: There are no known hazards with the use or handling of RHINO WHITE polyester. Vermin: RHINO WHITE® polyester is naturally resistant to insect and vermin attack.

PRODUCT DESCRIPTION

Our RHINO WHITE WALL & CEILING BATTS are

100% polyester thermal insulation segments pre-cut to fi t common timber framed walls, ceilings and mid-fl oor joist spacings.

R H I N O W H I T EWALL & CEILINGB A T T STHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 14: rhino range by thor building 2016

11

RHINO WHITE SOUND BATTS & ROLLSfor acoustic applications

Product Description Product Code Pieces/pack Sq m/pack

Sound BattsR1.5 Rhino White Sound Batt 75mm x 1160mm x 430mm WRSBatt-R1.5-430 8 3.99

R1.5 Rhino White Sound Batt 75mm x 1160mm x 580mm WRSBatt-R1.5-580 8 5.38

R2.0 Rhino White Sound Batt 90mm x 1160mm x 430mm WRSBatt-R2.0-430 8 3.99

R2.0 Rhino White Sound Batt 90mm x 1160mm x 580mm WRSBatt-R2.0-580 8 5.38

R2.5 Rhino White Sound Batt 100mm x 1160mm x 430mm WRSBatt-R2.5-430 8 3.99

R2.5 Rhino White Sound Batt 100mm x 1160mm x 580mm WRSBatt-R2.5-580 8 5.38

Sound RollsR2.5 Rhino White Sound Roll 100mm x 1160mm x 430mm WRSRoll-R2.5-430 3 14.96

R2.5 Rhino White Sound Roll 100mm x 1160mm x 580mm WRSRoll-R2.5-580 2 13.46

RHINO WHITE POLYESTER SOUND BATTS & ROLLS

APPLICATIONSRHINO WHITE SOUND BATTS & ROLLS is ideally suited for use in timber framed walls and mid-fl oor cavitites for reducing airborne sound transfer. RHINO WHITE SOUND BATTS & ROLLS reduces resonating noise in the construction cavity thereby reducing the sound energy transferred from one side to the other. Further improvements can be achieved by using acoustically rated plasterboard, multiple layers of plasterboard, or by isolating the plasterboard from the stud. The Building Code of Australia (BCA) sets out minimum performance ratings for inter-tenancy walls and fl oor-ceiling construction. The performance of a construction system relies on the design, materials and installation. Acoustic design for BCA compliance requires specialist design considerations. For information and assistance please contact your THOR BUILDING PRODUCTS Representative.

PERFORMANCEBuilding Regulations: RHINO WHITE INsulation will support and assist in meeting the following provisions of the BCA: BCA Volume One - Class 2-9 Buildings, Section J - Energy Effi ciency: Performance requirement JP1 BCA Volume One - Class 2-3 and 9c Buildings, Section F - Health and Amenity: Sound Transmission and INsulation. Performance requirement FP5.1, FP5.2, FP5.4 and FP 5.5. BCA Volume Two - Class 1 and Class 10 Buildings, Part 2.6 - Energy Effi ciency: Performance requirement P2.6.1 Part 3.8.6 - Health and Amenity, Sound Insulation: Performance requirements P2.4.6

Acoustic Performance - Rw is the industry accepted means of determining a material or assembly’s ability to resist airborne sound transfer. A higher Rw rating blocks more noise from transmitting through a construction system. RHINO Thermal Insulation will assist in reducing the resonating noise inside the construction cavity. Typical improvement in sound transmission loss through walls with the use of RHINO WHITE SOUND BATTS & ROLLS is ans increase of 5-8 Rw points, effectively reducing loud voices to a slight murmur. Typical improvement in sound transmission loss through a common residential mid-fl oor construction with the use of RHINO WHITE SOUND BATTS & ROLLS is an increase of 5-7 Rw points.

Thermal Performance - RHINO WHITE Insulation complies with the requirements as set out in AS/NZS4859.1 standard for insulation. For increased thermal performance options, Autex recommends the use of the RHINO Thermal Insulation range.

TECHNICAL Durability: RHINO WHITE Insulation has a 50 Year Durability Warranty. RHINO WHITE thermal insulation when installed in accordance with the manufacturer’s instructions will satisfy the 50 year durability criteria for minimum design life as set out in the ABCB guidance document Durability in Buildings 2006 (Section 2.4).

PRODUCT DESCRIPTION

RHINO WHITE SOUND is a 100% polyester acoustic

insulation material designed for timber framed

residential and light commercial applications.

Supplied in batts and rolls pre-cut to fi t standard

timber framed walls and mid-fl oor joist spacings.

R H I N O W H I T ESOUNDBATTS & ROLLS

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 15: rhino range by thor building 2016

12

RHINO WHITE SOUND BATTS & ROLLSfor acoustic applications

MoistureRHINO WHITE SOUND BATTS & ROLLS INSULATION is not affected by moisture. Exposure to an atmosphere of 50°C at 90% relative humidity for four days showed moisture absorption by weight of less than 0.03%.

Hazardous Building Materials - Non hazardous.

VOC Emission SafeVOC Concentration - 0.01mg/m3 (7 days)

GECA/Green Guard Limit - 0.25mg/m3 (7 days)

Non Corrosive - pH7.8 (pH7 is neutral)

Non Toxic, Non Allergenic, Non Irritant - There are no known hazards with the use or handling of RHINO INSULATION polyester.

Vermin -Naturally resistant to insect and vermin attack.

Non Flammable - Classifi ed non fl ammable.

Fire ratingsISO 9705: 1993Australian Group Number: Group 1SMOGRARC: Less than 100m/sReport Number: 02116

AS1530.3Ignitability Index (0-20) 0Heat Evolved Index (0-10) 0Spread of Flame Index (0-10) 0Smoke Developed Index (0-10) 3

IEC 60695-11-5 (Downlight Fire Test Standard)RHINO WHITE INSULATION has been tested and certifi ed non-fl ammable and complies with the requirements of IEC 60695-11-5. Certifi cates available.

InstallationThor Building Products Pty Ltd recommends that all thermal and acoustic insulation be installed in accordance with the manufacturers instructions (included on each RHINO pack) and AS 3999:1992 Thermal Insulation of Dwellings - Bulk Insulation, installation requirements.

MSDSMaterial Safety Data Sheets (MSDS) are available on request from your Thor Representative or by visiting our website: www.autex.com.au

Specifi cation & SubstitutionThor specifi cation documents are available from our website (www.thorbuilding.com.au). Substitution of any products should not be accepted and we recommend this be made clear in all specifi cation and tender documents.

Take Back ProgrammeThor will take back to recycle, uncontaminated RHINO WHITE insulation to help keep it out of landfi ll. For more information on recycling RHINO WHITE contact THOR on freephone 1300 880 828.

ISO StandardsTHOR BUILDING PRODUCTS PTY LTD is committed to Quality and environmental best practice through our ISO 9001 & ISO 14001 certifi ed Quality and Environmental Management Systems.

PRODUCT DESCRIPTION

RHINO WHITE SOUND is a 100% polyester acoustic

insulation material designed for timber framed

residential and light commercial applications.

Supplied in batts and rolls pre-cut to fi t standard

timber framed walls and mid-fl oor joist spacings.

R H I N O W H I T ESOUNDBATTS & ROLLS

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 16: rhino range by thor building 2016

13

RHINO WHITE PARTITION & ACOUSTIC BLANKETSacoustic blanket, commercial partition &high performance in fi ll

APPLICATIONSRHINO WHITE Partition &Acoustic Blankets can be used in metal and timber stud partition walls and as an acoustic ceiling overlay for reducing airborne sound transfer. The use of RHINO Partition Blankets reduce resonating noise in the construction cavity there by increasing the sound transmission loss of the construction system. The Building Code of Australia (BCA) sets out minimum performance ratings for inter-tenancy walls and fl oor-ceiling construction. Acoustic design for code compliance requires specialist design considerations. For information and assistance please contact your THOR Representative.

TECHNICALDurability: RHINO WHITE Partition & Acoustic Blankets have a SO Year Durability Warranty.

Moisture: RHINO WHITE Partition & Acoustic Blankets are not affected by moisture. Exposure to an atmosphere of 50OC at 90% relative humidity for four days showed moisture absorption by weight of less than 0.03%.

Hazardous Building Materials: is non hazardous.

VOC Emission Safe: VOC concentration: 0.01 mg/m3 (7 days). G ECA/GreenGuard Limit: 0.25 mg m3 (7 days). Cetec Pty Ltd (Report: RCV080408)

Non Corrosive: polyester is pH7.8 (pH7 is neutral). Non Toxic, Non Allergenic, Non Irritant: There are no known hazards with the use or handling of RHINO WHITE Partition & Acoustic Blankets.

Vermin: naturally resistant to insect and vermin attack.

Non Flammable: classifi ed non fl ammable.

MSDS: Material Safety Data Sheets (MSDS) are available on request from your THOR Representative or by visiting our website: www.autex.com.au

Specifi cation & Substitution: THOR specifi cation documents are available and can be downloaded from our website (www.autex.com.au). The performance and design of the THOR Partition Blanket range has been engineered to supply a proven sound control system. Substitution of any specifi ed components in a sound control system can signifi cantly compromise the system performance. Products of similar weight and density may not provide equivalent performance, as small variations in fi bre size; structure and bonding will effect performance. Accept NO substitutions.

Take Back Programme: THOR will gladly recycle used, uncontaminated RHINO insulation to help keep it out of landfi ll. For more information on recycling RHINO WHITE, contact THOR BUILDING PRODUCTS on 1300 880 828.

ISO Standards: THOR is committed to Quality and Environmental best practice through our ISO 9001 & ISO 14001 certifi ed Quality and Environmental Management Systems.

Acoustic Performance: Performance results are typically reported as RW ratings for partition walls. The construction method, linings and insulation will all contribute to the performance of the partition wall.The acoustic performance ratings described in the following performance tables are valid for metal stud partition walls using 0.551lm steel stud set at 600mm centres (as described in the systems tables). Dependent on the system, installing the correct RHINO Partition Blanket can improve the value between 3 -10 RW points. For design advice on a specifi c system contact your THOR Representative.

RHINO WHITE SOUND BLANKETRHINO WHITE Sound Blanket is an acoustic insulation ideally suited as a partition infi ll for interior and commercial fi t out applications to improve acoustic separation between adjoining spaces. Being 100% polyester it’s completely safe to the installer and building occupiers. Supplied in roll form to allow fast and effi cient use and minimise waste. RHINO WHITE BLANKET is available in a range of thickness’s to suit the required stud depth and performance rating.

PRODUCT DESCRIPTION

RHINO Partition Blanket is a range of 100% polyester

acoustic insulation products designed to improve the

acoustic performance of partition walls and

ceiling systems. Pre-cut to fi t standed metal stud partitions set at 450 and

600mm centres.

R H I N O W H I T EPARTITION & ACOUSTICBLANKETSTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 17: rhino range by thor building 2016

14

RHINO WHITE PARTITION & ACOUSTIC BLANKETSacoustic blanket, commercial partition &high performance in fi ll

PRODUCT THICKNESS DIMENSIONS ROLL/PACK M2/ PACK

WRA Blanket-40-610WRA Blanket-40-450

40 610 x16.5m450 x16.5m

23

20.1322.28

WRA Blanket-50-610WRA Blanket-50-450

50 610 x16.5m450 x16.5m

23

20.1322.28

WRA Blanket-60-610WRA Blanket-60-450

60 610 x16.5m450 x16.5m

23

20.1322.28

WRA Blanket-70-610WRA Blanket-70-450

70 610 x16.5m450 x16.5m

23

20.1322.28

WRA Blanket-80-610WRA Blanket-80-450

80 610 x16.5m450 x16.5m

23

20.1322.28

WRA Blanket-90-610WRA Blanket-90-450

90 610 x12.0m450x12.0m

23

14.6416.20

PRODUCT Kg/ M3 THICKNESS DIMENSIONS ROLL/PACK M2 / PACK

WRP Blanket-50-610-11WRP Blanket-50-450-11

11 50 610 x15m450 x15m

23

18.3020.25

WRP Blanket-75-610-11WRP Blanket-75-450-11

11 75 610 x15m450 x15m

23

18.3020.25

WRP Blanket-50-610-14WRP Blanket-50-450-14

14 50 610 x15m450 x15m

23

18.3020.25

WRP Blanket-75-610-14WRP Blanket-75-450-14

14 75 610 x15m450 x15m

23

18.3020.25

WRP Blanket-90-610-14WRP Blanket-90-450-14

14 90 610 x12m450 x12m

23

14.6416.20

RHINO WHITE COMMERCIAL PARTITION BLANKETRHINO WHITE COMMERCIAL PARTITION BLANKET is an acoustic infi ll insulation designed to meet the standard industry weight based requirements of many common referenced RW rated partition wall and ceiling systems. RHINO WHITE COMMERCIAL PARTITION BLANKET is supplied standard in either 11 or 14kgm3 and ranged in thickness’s to suit the specifi ed stud depth and acoustic rating. To ensure optimal performance it is recommended to match the product thickness as closely as possible to the stud depth. RHINO WHITE COMMERCIAL PARTITION BLANKET is supplied in roll form to allow fast and effi cient installation of the product helping minimise material and labour costs. Being 100% polyester it is non toxic and completely safe for the installer and building occupiers.

HIGH PERFORMANCE INFILLRHINO WHITE PERFORMANCE INFlLL is a range of acoustic insulation specifi cally engineered to max-imise the acoustic performance of partition wall and ceiling systems. RHINO WHITE PERFORMANCE INFILL improves the acoustic separation by reducing noise intrusion and increasing sound privacy be-tween spaces. HPI should be used where optimal acoustic performance is required. Manufactured from 100% polyester RHINO WHITE PERFORMANCE IN FILL is completely safe for installer and building occupiers and has no known health hazards.

ON-SITE INFORMATIONRHINO WHITE Partition & Acoustic Blankets products are compression packed to minimize transportation costs and ease on-site storage and handling. Prior to use the packs should be opened to allow recovery of the insulation loft. Product recovery to the stated nominal thickness may be slowed by low temperatures and extended periods of storage in compressed packaging. Installing product at less than the stated nominal thickness does not hinder long-term acoustic performance. These products are proven to recover in-situ over time. The RHINO WHITE Partition & Acoustic Blankets range is blue colour tinted to provide easy Identifi cation on site. If RHINO WHITE Partition & Acoustic Blankets products have been specifi ed and the insulation material is not blue tinted, it is not a RHINO WHITE Partition & Acoustic Blankets and instructions should be issued to cease Installation until the correct specifi ed material is supplied. Equivalent weight and thickness products may not provide equivalent acoustic performance as small changes to fi bre size, blend and fi bre bonding effect the products performance. Acoustic insulation should be installed with no gaps. Where required, drops

PRODUCT THICKNESS DIMENSIONS ROLL/PACK M2/ PACK

WRH lnfi ll-60-610WRH lnfi ll-60-450

60 610mm x8.2m450mm x8.2m

23

10.0011.07

WRH lnfi ll-90-610WRH lnfi ll-90-450

90 610mm x8.2m450mm x8.2m

23

10.0011.07

WRH lnfi ll-165-610WRH lnfi ll-165-450

165 610mm x6.0m450mm x6.0m

23

7.328.10

PRODUCT DESCRIPTION

RHINO Partition Blanket is a range of 100% polyester

acoustic insulation products designed to improve the

acoustic performance of partition walls and

ceiling systems. Pre-cut to fi t standed metal stud partitions set at 450 and

600mm centres.

R H I N O W H I T EPARTITION & ACOUSTICBLANKETSTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 18: rhino range by thor building 2016

15

RHINO WHITE PARTITION & ACOUSTIC BLANKETSacoustic blanket, commercial partition &high performance in fi ll

should be mechanically fi xed at the top to secure in place until the plasterboard linings are installed. Insulation can be torn by hand across the width of the rolls for length. If the Insulation needs to be cut we suggest using sharp scissors or a wavy edge type Swlbo Knife. Partition Blanket products are designed to be used in metal and timber stud walls.

The RHINO WHITE Partition & Acoustic Blankets range can be used as an acoustic ceiling overlay to help reduce sound transfer between rooms and spaces, and reduce reverberation times in when used behind perforated or panel type systems. (RHINO WHITE Partition & Acoustic Blankets is specifi cally designed for reverberation control in this application). Performance will vary depending on the ceiling system design and installation. For design advice and assistance please contact your THOR Representative.

The acoustic performance stated in this document are based on testing, prediction & opinion. All studs are set out at 600mm centres. Performance on site can vary dependent on installation and limitations on site such as fl anking paths. THOR recommends specifying higher than the minimum required performance level to help ensure the Client’s expectations are satisfi ed. For assistance on your project please contact your local THOR Account Manager.

ENVIRONMENTAL DESIGNThe Green Building Council of Australia (GBCA) has developed assessment tools to determine an overall Green Star rating. The use of RHINO WHITE INSULATION can contribute to points available in the various tools as set out in the table below.

SYSTEM DESCRIPTION INSULATION TYPE

INSULATION THICKNESS

SYSTEM RATING

RW RW + CTR

1 x layer 10mm Plasterboard each side 64mm metal stud partition waII.

WRA Blanket-60WRA Blanket -70

WRH lnfi ll-60

607060

394041

---

1 x layer 13mm Plasterboard each side 64mm metal stud partition waII.

WRA Blanket-60WRA Blanket -70

WRH lnfi ll-60

607060

414243

---

2 x layers 13m m Plasterboard one side 1 x layer 13m m Plasterboard other side of 92m m metal

stud partition wall.

WRA Blanket-60WRA Blanket-90-14

WRH lnfi ll-90

609090

474950

---

2x 10 mm Plasterboard each side 92mm metal stud partition wall.

WRA Blanket-70WRA Blanket-75-11

WRH lnfi ll-60

707590

484950

---

2x 13mm FR rated Plasterboard each side 92mm metal stud partition walls.

WRA Blanket-80WRA Blanket-90-14

WRH lnfi ll-90

809090

545556

---

2 x layers 13mm FR rated Plasterboard each side staggered metal stud partition walls using

150mm track.

WRA Blanket-70WRA Blanket -75-11

WRH lnfi ll-75-14

707575

575859

515253

1 x 16mm FR rated Plasterboard each side double metal stud wall 64mm metal studs wall thickness 204mm. discontinuous construction.

WRH lnfi ll-165WRP Blanket-60

165mm + 60 59 51

Green Star Tool

Categories

Management (Man)

Materials (Mat) Indoor Environment Quality (EQ)

Emissions (Emi)

Education v1

Waste Management

Mat-3 - - Internal noise -

Insulant ODP

-

Healthcare v1 - - Mat 14 - VOC -

Industrial v1 - - -

Internal noise

- Noise Pollution

Multi Unit Residential v1 Mat3 - Mat 14 - -

Offi ce Design and as built v3 - Mat4 - - -

Offi ce Interiors v1.1 Mat3 - - - - - -

Retail Centre v1 - - - - - Insulant ODP -

PRODUCT DESCRIPTION

RHINO Partition Blanket is a range of 100% polyester

acoustic insulation products designed to improve the

acoustic performance of partition walls and

ceiling systems. Pre-cut to fi t standed metal stud partitions set at 450 and

600mm centres.

R H I N O W H I T EPARTITION & ACOUSTICBLANKETSTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 19: rhino range by thor building 2016

16

RHINO WHITE PARTITION & ACOUSTIC BLANKETSacoustic blanket, commercial partition &high performance in fi ll

MANAGEMENT. (MAN)Waste management:THOR can arrange the take back of uncontaminated RHINO WHITE Insulation for re-processing, helping keep it out of landfi ll. Please contact your THOR Account Manager for further details.

MATERIALS (MAT)Green Star Materials credits aim to improve the environmental impacts of building products and materials. RHINO WHITE will assist in achieving the available credits in the applicable calculators RHINO has a 50+year durability warranty, high recycled content and manufactured to independently certifi ed EMS protocols.

INDOOR ENVIRONMENT QUALITY (IEQ)Internal Noise and VOC:The use on RHINO WHITE products will by their nature contribute to the reduction of internal noise levels when used as part of the design for internal acoustic performance of the space. THOR’ RHINO WHITE INSULATION RANGE has been independently tested and is well below the allowable limits for VOC concentrations and considered to be formaldehyde free.

EMISSIONS (EMI)Ozone depleting substances (ODP) and Noise pollution:Encourages the reduction of emissions via material selection and the in use application of the development. RHINO WHITE Insulation does not contain or produce ozone depleting substances. The use on RHINO WHITE Partition Blankets can contribute to the reduction of noise omissions from the development when used as part of the design for acoustic control.

PRODUCT DESCRIPTION

RHINO Partition Blanket is a range of 100% polyester

acoustic insulation products designed to improve the

acoustic performance of partition walls and

ceiling systems. Pre-cut to fi t standed metal stud partitions set at 450 and

600mm centres.

R H I N O W H I T EPARTITION & ACOUSTICBLANKETSTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 20: rhino range by thor building 2016

17

RHINO WHITE SOUND BAFFLEfor acoustic applications

APPLICATIONSRHINO WHITE SOUND BAFFLE is designed for use above new or existing RW rated partition walls to enhance the acoustic privacy between spaces.

APPLICATION CONSIDERATIONSRHINO WHITE SOUND BAFFLE must be installed with at least enough compression to ensure stack stability and a tight fi t to all surfaces including concrete slab, ceiling or the fl oor above. No gaps to be allowed through the stack.

RHINO WHITE SOUND BAFFLE can be installed to a height of 1m without specialist design considerations. Above this height consideration must be given to the stack stability and weight loading restrictions on the ceiling tiles and grid system. Other options are available for plenum heights above 1m.

Where the ceiling plenum is used as an active return for the air conditioning system, ensure air fl ow is not signifi cantly reduced. Thor Building Products recommends you consult the Mechanical Services Engineer to ensure the use of RHINO WHITE SOUND BAFFLE will not result in a loss of effect air movement.

Existing services, ducting, ceiling grid supports and fi re control and detection devices must not be affected by the installation. RHINO WHITE SOUND BAFFLE should not be used where temperatures exceed 160oC. Where fl ues or similar heat emitting items pass through the insulation, a 200mm venting gap should be left between that item and the insulation. For more information please discuss your requirements with your Rhino Representative.

TECHNICALBCA Compliance: RHINO WHITE lnsulation when Installed in accordance with the manufacturer’s instructions will satisfy the 50 year durability criteria for minimum design life as set out in the ABCB guidance document Durability in Buildings 2006 (Section 2.4).

Durability: RHINO WHITE SOUND BAFFLE Insulation has a 50 Year Durability Warranty.

Moisture: RHINO WHITE Insulation is not affected by moisture. Exposure to an atmosphere of 50oC at 90% relative humidity for four days showed moisture absorption by weight of less than 0.03%.

Hazardous Building Materials: non-hazardous.

VOC Emission Safe: VOC concentration: 0.01 mg/m3 (7 days). GECA/ Green Guard Limit: 0.25 mg/m3 (7 days). cetec Pty Ltd (Report: RCV080408)

Non-Flammable: non-fl ammable.

Fire ratings: ISO 9705:

1993 www.autex.co.nz classifi cation: Group 1 SMOGRARC: Less then 100m2/s2Report number FAR4045

AS1530.3lgnitability Index (0-20) 0Heat Evolved Index (0-10) 0Spread of Flame Index (0-10) 0Smoke Developed Index (0-10) 3APL Report 98055

Non-Corrosive: pH7. 8 (pH 7 is neutral)

Non-Toxic, Non-Allergenic, Non-Irritant: There are no known hazards with the use or handling of RHINO WHITE polyester.

Vermin: RHINO WHITE Insulation is naturally resistant to insect and vermin attack

Installation: RHINO WHITE Insulation should be installed as a layer stack above RW rated partition walls. RHINO WHITE Insulation must be Installed with enough compression to ensure stack stability and a tight fi t to all surfaces including slab, roof or fl oor above. No gaps to be allowed through the stack and small pieces should be used to fi ll around ducting, services and structural components. Consult with the HVAC Installer/Engineer prior to commencing to ensure no loss of effective air movement to the active return of the air conditioning system.

Additional information and advice is available from your RHINO Representative or by phoning Thor Building Customer Services free phone 1300 880 828

MSDS: Material Safety Data Sheets (MSDS) are available on request from your THOR Representative or by visiting our website: www.thorbuilding.com.au

Specifi cation & Substitution: Thor Building specifi cation documents are available and

PRODUCT NOMINAL THICKNESS (mm) Pack Size m2/PACK

WRB Block-100-600 100 mm 600mm wide x 8.33Lm x 2 rolls 10m2

PRODUCT DESCRIPTION

RHINO WHITE SOUND BAFFLE is a 100% polyester acoustic insulation product

designed to be layer stacked above partition walls to reduce sound

transmission through the ceiling plenum space and is supplied as rolls pre-cut to

600mm wide.

R H I N O W H I T ES O U N DB A F F L ETHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 21: rhino range by thor building 2016

18

RHINO WHITE SOUND BAFFLEfor acoustic applications

can be downloaded from our website www.thorbuilding.com.au. The performance and design of RHINO WHITE has been engineered to supply a tested and proven sound control system.

Substitution of any specifi ed components in a sound control system can signifi cantly compromise the system performance.

Accept NO substitutions.

Take Back Programme: We will gladly recycle used, uncontaminated RHINO WHITE insulation to help keep it out of landfi ll. For more information on recycling RHINO WHITE contact THOR BUILDING PRODUCTS on 1300 880 828.

ISO Standards: Thor Building Products is committed to Quality and Environmental best practice through our ISO 9001 & ISO 14001 certifi ed Quality and Environmental Management Systems.

Acoustic Performance: All performance results are based on testing carried out in a laboratory environment. On-site results could vary depending on the system design, materials and quality of the installation.

For more information and assistance please contact your THOR Representative.

ACOUSTIC PERFORMANCE

FREQUENCY (Hz) Installed Product Density:11 kg/m3 Stack Compression: 10%

Installed Product Density:15 kg/m3 Stack Compression: 33%

Installed Product Density:16 kg/m3 Stack Compression: 40%

63 5.22 5.76 6.73

125 7.75 8.38 9.34

250 7.27 8.24 9.01

500 13.15 14.35 15.64

1000 15.25 17.01 18.42

2000 16.56 18.71 20.17

4000 19.53 22.56 24.21

8000 18.30 20.54 21.78

Insertion loss (dBA)

12.9 14.1 15.2

* Tested through the 600 mm section of the material

PRODUCT DESCRIPTION

RHINO WHITE SOUND BAFFLE is a 100% polyester acoustic insulation product

designed to be layer stacked above partition walls to reduce sound

transmission through the ceiling plenum space and is supplied as rolls pre-cut to

600mm wide.

R H I N O W H I T ES O U N DB A F F L ETHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 22: rhino range by thor building 2016

19

RHINO CELL 104 AG

Application Heat Flow In Heat Flow Out

Warehouse metal roof retrofi t, fully sealed R-3.0 R-0.8

Floor, suspended timber enclosed sub fl oor R-3.1 R-1.6

Commercial offi ce metal roof, with ceiling R-3.5 R-1.2

Residential Pitched Metal roof 22°, ventilated R-2.5 R-1.1

Brick veneer wall R-1.9 R-2.1

Product Code Description Thickness (mm) R-Value (m2K/W) Dimensions (m) m2/pack

RC-104 AG Rhino Cell Antiglare

4mm R-0.10 1.35 (+0.15m fl ap) x 22.25(pack 0.32 dia. x 1.5)(pack mass 11.5kg)

30

Test Description Parameter

ASTM E - 408 Emissivity refl ective face = 0.03 ± 0.01antiglare face = 0.05 ± 0.01

AS/NZS 4859.1 App – I Surface Corrosion Pass

AS/NZS 4859.1 App – H Corrosiveness Pass

ASTM 1530.2 Flammability Low (index ≤ 5)

ASTM 1530.3 Early Fire Hazard Ignitability index - N/ASpread of Flame - ≤ 9

Heat Evolved Ind. - N/ASmoke developed Ind. - ≤ 5

AS/NZS 3837 Cone Calorimeter BCA Classifi cation 1

AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVY

TAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY

AS 2001.2.19 Bursting Strength Stated

AS 4201.1 Resistance to Dry Delamination Pass

AS 4201.2 Resistance to Wet Delamination Pass

AS 4201.3 Shrinkage ≤ 5%

AS 4201.4 Water Barrier High

AS 4201.6 Absorbency Unclassifi ed

ASTM E-96 Vapour Transmission Medium

THERMAL PERFORMANCE

FINISHED PRODUCT PERFORMANCECompliance to AS 4859.1 & AS4200.1

Product Specifi cation

Width 1.35m (+0.15m fl ap)

Length 22.25m

Area 30m2

Thickness 4mm ± 1mm

Laminate 1 Polyethylene weave Al Foil

Bubble Composition Polyethylene

Laminate 2 Polyethylene weave Al Foil

R values shown are Total R values for the building element calculated by a chartered professional engineer and verifi ed by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the

requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K.

The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.

PRODUCT DESCRIPTION

Rhino Cell 104 is a 3 in 1 insulation, vapour barrier

and radiant heat barrier for use in roof, wall and fl oor

systems.

The fi bre-free, non-allergenic, formaldehyde

free materials used in Rhino Cell provide a safe

solution which is also easy to install.

Rhino Cell is strong, durable, has low

fl ammability index (≤5) and is both rodent and insect

resistant.

Available in Blue Antiglare surface fi nish.

R H I N O C E L L1 0 4 A GTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Manufacturing Process:

Page 23: rhino range by thor building 2016

20

RHINO CELL 310 AG

Application Heat Flow In Heat Flow Out

Warehouse metal roof with ceiling 300mm, no vent R-3.6 R-1.3

Residential metal pitched roof 22° steel frame, ventilated R-2.6 R-1.2

Warehouse metal roof, no ceiling fully sealed R-2.1 R-1.0

Product Code Description Thickness (mm) R-Value (m2K/W) Dimensions (m) m2/pack

RC-310 AG Rhino Cell Antiglare

11mm R-0.20 1.35 x 22.25(pack 0.49 dia. x 1.5)(pack mass 12.5kg)

30

Test Description Parameter

ASTM E - 408 Emissivity refl ective face = 0.03 ± 0.01antiglare face = 0.05 ± 0.01

AS/NZS 4859.1 App – I Surface Corrosion Pass

AS/NZS 4859.1 App – H Corrosiveness Pass

ASTM 1530.2 Flammability Low (index ≤ 5)

ASTM 1530.3 Early Fire Hazard Ignitability index - N/ASpread of Flame - ≤ 9

Heat Evolved Ind. - N/ASmoke developed Ind. - ≤ 5

AS/NZS 3837 Cone Calorimeter BCA Classifi cation 1

AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVY

TAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY

AS 2001.2.19 Bursting Strength Stated

AS 4201.1 Resistance to Dry Delamination Pass

AS 4201.2 Resistance to Wet Delamination Pass

AS 4201.3 Shrinkage ≤ 5%

AS 4201.4 Water Barrier High

AS 4201.6 Absorbency Unclassifi ed

ASTM E-96 Vapour Transmission Medium

THERMAL PERFORMANCE

FINISHED PRODUCT PERFORMANCECompliance to AS 4859.1 & AS4200.1

Product Specifi cation

Width 1.35m (+0.15m fl ap)

Length 22.25m

Area 30m2

Thickness 11mm

Laminate 1 Polyethylene weave Al Foil

Bubble Composition Polyethylene

Laminate 2 Polyethylene weave Al Foil

R values shown are Total R values for the building element calculated by a chartered professional engineer and verifi ed by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the

requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K.

The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.

PRODUCT DESCRIPTION

Rhino Cell 310 Thermal Break is a 3 in 1 insulation, vapour barrier and radiant heat barrier for use in roof,

wall and fl oor systems.

The fi bre-free, non-allergenic, formaldehyde

free materials used in Rhino Cell provide a safe

solution which is also easy to install.

Rhino Cell is strong, durable, has low

fl ammability index (5) and achieves a Thermal Break

of R-0.2.

Available in Blue Antiglare surface fi nish.

UNIQUE 150MM FLAP ELIMINATES

NEED FOR OVERLAP SAVING UP TO 10%

R H I N O C E L L3 1 0 A GTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

FLAP FOR ADDED COVERAGE

b

Manufacturing Process:

Page 24: rhino range by thor building 2016

21

RHINO SHED

Application Heat Flow In Heat Flow Out

Shed metal roof retrofi t, fully sealed R-3.0 R-0.8

Shed metal roof, with ceiling R-3.5 R-1.2

Shed pitched metal roof 22°, ventilated R-2.5 R-1.1

Shed metal clad wall, 100mm air gap R-1.1 R-1.2

Product Code Description Thickness (mm) R-Value (m2K/W) Dimensions (m) m2/pack

RSHD Rhino Shed 4mm R-0.10 1.35 x 22.25(pack 0.32 dia. x 1.35)

(pack mass 11.5g)

30

Test Description Parameter

ASTM E - 408 Emissivity refl ective face = 0.03 ± 0.01

AS/NZS 4859.1 App – I Surface Corrosion Pass

AS/NZS 4859.1 App – H Corrosiveness Pass

ASTM 1530.2 Flammability Low (index ≤ 5)

ASTM 1530.3 Early Fire Hazard Ignitability index - N/ASpread of Flame - ≤ 9

Heat Evolved Ind. - N/ASmoke developed Ind. - ≤ 5

AS/NZS 3837 Cone Calorimeter BCA Classifi cation 1

AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVY

TAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY

AS 2001.2.19 Bursting Strength Stated

AS 4201.1 Resistance to Dry Delamination Pass

AS 4201.2 Resistance to Wet Delamination Pass

AS 4201.3 Shrinkage ≤ 5%

AS 4201.4 Water Barrier High

AS 4201.6 Absorbency Unclassifi ed

ASTM E-96 Vapour Transmission Medium

THERMAL PERFORMANCE

FINISHED PRODUCT PERFORMANCECompliance to AS 4859.1 & AS4200.1

Product Specifi cation

Width 1.350m

Length 22.25m

Area 30m2

Thickness 4mm ± 1mm

Laminate 1 Polyethylene weave Al Foil

Bubble Composition Polyethylene

Laminate 2 Polyethylene weave Al Foil

R values shown are Total R values for the building element calculated by a chartered professional engineer and verifi ed by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the

requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K.

The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.

PRODUCT DESCRIPTION

Rhino Cell 310 Thermal Break is a 3 in 1 insulation, vapour barrier and radiant heat barrier for use in roof,

wall and fl oor systems.

Rhino Shed is a 3 in 1 insulation, vapourbarrier

and radiant heat barrier for use in shed walls and shed under-roof systems where antiglare is not requested.

The fi bre-free, non-allergenic, formaldehyde

free materials used in Rhino Shed provides a safe solution which is also easy

to install.

R H I N O S H E DTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Manufacturing Process:

Page 25: rhino range by thor building 2016

22

RHINO CELL CAVITY WALL

Application Heat Flow In Heat Flow Out

Warehouse metal roof retrofi t fully sealed R-3.0 R-0.8

Floor, suspended timber enclosed sub fl oor R-3.1 R-1.6

Commercial offi ce metal roof, with ceiling R-3.5 R-1.2

Residential Pitched Metal roof 22°, ventilated R-2.5 R-1.1

Brick veneer wall R-1.9 R-2.1

THERMAL PERFORMANCE

Product Specifi cation

Width 1.35m

Length 22.25m

Area 30m2

Thickness 4mm ± 1mm

Laminate 1 Polyethylene weave Al Foil

Bubble Composition Polyethylene

Laminate 2 Polyethylene weave Al Foil

R values shown are Total R values for the building element calculated by a chartered professional engineer and verifi ed by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the

requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K.

The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.

Product Code Description Thickness (mm) R-Value (m2K/W) Dimensions (m) m2/pack

RC-CW AG Rhino Cell Cavity Wall

4mm R-0.10 1.35 x 22.25(pack 0.32 dia. x 1.35)

(pack mass 11.5g)

30

Test Description Parameter

ASTM E - 408 Emissivity refl ective face = 0.03 ± 0.01antiglare face = 0.03 ± 0.01

AS/NZS 4859.1 App – I Surface Corrosion Pass

AS/NZS 4859.1 App – H Corrosiveness Pass

ASTM 1530.2 Flammability Low (index ≤ 5)

ASTM 1530.3 Early Fire Hazard Ignitability index - N/ASpread of Flame - ≤ 9

Heat Evolved Ind. - N/ASmoke developed Ind. - ≤ 5

AS/NZS 3837 Cone Calorimeter BCA Classifi cation 1

AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVY

TAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY

AS 2001.2.19 Bursting Strength Stated

AS 4201.1 Resistance to Dry Delamination Pass

AS 4201.2 Resistance to Wet Delamination Pass

AS 4201.3 Shrinkage ≤ 5%

AS 4201.4 Water Barrier Low

AS 4201.6 Absorbency Unclassifi ed

ASTM E-96 Vapour Transmission Medium

FINISHED PRODUCT PERFORMANCECompliance to AS 4859.1 & AS4200.1

PRODUCT DESCRIPTION

Rhino Cell Cavity Wall is a 3 in 1 insulation vapour-permeable and radiant

heat barrier for use in wall systems.

The fi bre-free, non-allergenic, formaldehyde

free materials used in Rhino Cell Cavity Wall

provide a safte solution which is easy to install.

Rhino Cell Cavity Wall is strong, durable, has low

fl ammability index (≤5) and is both rodent and insect

resistant.

Available in Blue Antiglare surface fi nish.

RHINO CELL CAVITY WALL

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Manufacturing Process:

Page 26: rhino range by thor building 2016

23

RHINO CELL UNDERFLOOR

Application Heat Flow In Heat Flow Out

Warehouse metal roof retrofi t, fully sealed R-3.0 R-0.8

Floor, suspended timber enclosed sub fl oor R-3.1 R-1.6

Commercial offi ce metal roof, with ceiling R-3.5 R-1.2

Residential Pitched Metal roof 22°, ventilated R-2.5 R-1.1

Brick veneer wall R-1.9 R-2.1

Product Code Description Thickness (mm) R-Value (m2K/W) Dimensions (m) m2/pack

RC-UF AG Rhino Underfl oor 4mm R-0.10 0.50 x 30(pack 0.50 dia. x 1.50)

(pack mass 18.5g)

453 rolls/pack

Test Description Parameter

ASTM E - 408 Emissivity refl ective face = 0.03 ± 0.01antiglare face = 0.05 ± 0.01

AS/NZS 4859.1 App – I Surface Corrosion Pass

AS/NZS 4859.1 App – H Corrosiveness Pass

ASTM 1530.2 Flammability Low (index ≤ 5)

ASTM 1530.3 Early Fire Hazard Ignitability index - N/ASpread of Flame - ≤ 9

Heat Evolved Ind. - N/ASmoke developed Ind. - ≤ 5

AS/NZS 3837 Cone Calorimeter BCA Classifi cation 1

AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVY

TAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY

AS 2001.2.19 Bursting Strength Stated

AS 4201.1 Resistance to Dry Delamination Pass

AS 4201.2 Resistance to Wet Delamination Pass

AS 4201.3 Shrinkage ≤ 5%

AS 4201.4 Water Barrier High

AS 4201.6 Absorbency Unclassifi ed

ASTM E-96 Vapour Transmission Medium

THERMAL PERFORMANCE

FINISHED PRODUCT PERFORMANCECompliance to AS 4859.1 & AS4200.1

Product Specifi cation

Width 0.50m

Length 30m

Area 45m2

Thickness 4mm ± 1mm

Laminate 1 Polyethylene weave Al Foil

Bubble Composition Polyethylene

Laminate 2 Polyethylene weave Al Foil

R values shown are Total R values for the building element calculated by a chartered professional engineer and verifi ed by a recognised laboratory. Total R values of the above systems for winter and summer conditions have been determined in accordance with the

requirements of AS/NZS4859.1:2002 Amdt 1 (2006), App K.

The contribution of this product total R-value depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.

PRODUCT DESCRIPTION

Rhino Underfl oor is a 3 in 1 insulation, vapour-

permeable and radiant heat barrier for use in underfl oor

systems.

The fi bre-free, non-allergenic, formaldehyde

free materials used in Rhino Underfl oor provide a safe solution which is also

easy to install.

Rhino Underfl oor is strong, durable, has low

fl ammability index (5) and is both rodent and insect

resistant.

Available in Blue Antiglare surface fi nish.

RHINO CELL UNDERFLOOR

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Manufacturing Process:

Page 27: rhino range by thor building 2016

24

RHINO FOAM 40THERMAL BREAK

PRODUCT DESCRIPTIONRhino Foam 40 AG Thermal Break combines an inner layer of fire retardant foam core laminated to two layers of high performance reflective woven aluminium foil. This proudly Australian made insulation features an anti-glare coating on one side for safe, easy installation as well as advanced thermal performance reflecting up to 97% of radiant heat flow. Our Thermal break product provides an energy efficient solution for roof and wall applications in accordance with the BCA and is proudly Australian made.

Unique: 1500mm flap eliminates need for overlap, saving up to 10%.

Application Heat Flow In Heat Flow Out

Pitched Metal Roof, flat ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break)

2.8 1.3

Pitched Metal Roof (22° Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break)

1.7 1

Flat Metal Roof, suspended ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break)

3.9 1.4

Flat Metal Roof (Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break)

2.1 1

Metal Clad Wall 1.1 1.1

Metal Clad Wall & Plasterboard Lining 1.8 1.7

Double Brick Wall 2.1 2.1

Brick Veneer Wall 2 2

Product Code Description Thickness (mm) R-Value (m2K/W) Dimensions (m) m2/pack

RF-40 AG Rhino Foam 40 AG 4.0mm R-0.10 1350mm x 22.25m(+0.15m flap)

30

Test Description Parameter

ASTM E - 408 Emissivity Silver 0.03 / Anti-Glare 0.05

AS/NZS 4859.1 App – I Surface Corrosion Pass

AS/NZS 4859.1 App – H Corrosiveness Pass

ASTM 1530.2 Flammability Low (index ≤ 5)

ASTM 1530.3 Early Fire Hazard 0/0/0/1

AS/NZS 3837 Cone Calorimeter N/A

AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVY DUTY

TAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY DUTY

AS 2001.2.19 Bursting Strength Stated

AS 4201.1 Resistance to Dry Delamination Pass

AS 4201.2 Resistance to Wet Delamination Pass

AS 4201.3 Shrinkage ≤ 5%

AS 4201.4 Water Barrier High

AS 4201.6 Absorbency High

ASTM E-96 Vapour Transmission Medium

THERMAL PERFORMANCE

FINISHED PRODUCT PERFORMANCECompliance to AS 4859.1 & AS4200.1

SAFETY INSTRUCTIONSNo personal protective equipment is required, however, it is recommended that UV protective sunglasses be worn when installing outside. This product is non-hazardous. When installing ensure that all electrical cabling, fittings, and wiring are in a safe condition and there is no potential for contact with live wiring or down-lights. Ensure a minimum 50mm clearance from light fittings (check for safe distance with lighting supplier) and ensure 50mm clearance around hot flues. Plastic fixings should be used where any electrical componentry is in close vicinity of the installation materials. Do not use any metal fixings if working in close vicinity of electrical wiring.

RHINO FOAM 40THERMAL B R E A KTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Product Specification

Width 1350mm (+0.15m Flap)

Length 22.25m

Area 30m

Thickness 4.0 ± 1mm

Antiglare Reflectivity

95%

Silver Reflectivity

97%

Manufacturing Process:

Page 28: rhino range by thor building 2016

25

RHINO FOAM 75THERMAL BREAK

PRODUCT DESCRIPTIONRhino Foam 75 AG Thermal Break combines an inner layer of fire retardant foam core laminated to two layers of high performance reflective woven aluminium foil. This proudly Australian made insulation features an anti-glare coating on one side for safe, easy installation as well as advanced thermal performance reflecting up to 97% of radiant heat flow. Our Thermal break product provides an energy efficient solution for roof and wall applications in accordance with the BCA and is proudly Australian made.

Unique: 1500mm flap eliminates need for overlap, saving up to 10%.

Application Heat Flow In Heat Flow Out

Pitched Metal Roof, flat ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break)

2.8 1.3

Pitched Metal Roof (22° Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break)

1.7 1

Flat Metal Roof, suspended ceiling (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break)

3.9 1.4

Flat Metal Roof (Warehouse) (Fully-Sealed Airspace between Metal Roof & Oasis 7.0 Thermal Break)

2.1 1

Metal Clad Wall 1.1 1.1

Metal Clad Wall & Plasterboard Lining 1.8 1.7

Double Brick Wall 2.1 2.1

Brick Veneer Wall 2 2

Product Code Description Thickness (mm) R-Value (m2K/W) Dimensions (m) m2/pack

RF-75 AG Rhino Foam 75 AG 7.5mm R-0.20 1350mm x 22.25m(+0.15m flap)

30

Test Description Parameter

ASTM E - 408 Emissivity Silver 0.03 / Anti-Glare 0.05

AS/NZS 4859.1 App – I Surface Corrosion Pass

AS/NZS 4859.1 App – H Corrosiveness Pass

ASTM 1530.2 Flammability Low (index ≤ 5)

ASTM 1530.3 Early Fire Hazard 0/0/0/1

AS/NZS 3837 Cone Calorimeter N/A

AS 1301.448 Duty Rating, Tensile Strength EXTRA HEAVY DUTY

TAPPI T470 Duty Rating, Edge Tear Resistance EXTRA HEAVY DUTY

AS 2001.2.19 Bursting Strength Stated

AS 4201.1 Resistance to Dry Delamination Pass

AS 4201.2 Resistance to Wet Delamination Pass

AS 4201.3 Shrinkage ≤ 5%

AS 4201.4 Water Barrier High

AS 4201.6 Absorbency Unclassified

ASTM E-96 Vapour Transmission Medium

THERMAL PERFORMANCE

FINISHED PRODUCT PERFORMANCECompliance to AS 4859.1 & AS4200.1

SAFETY INSTRUCTIONSNo personal protective equipment is required, however, it is recommended that UV protective sunglasses be worn when installing outside. This product is non-hazardous. When installing ensure that all electrical cabling, fittings, and wiring are in a safe condition and there is no potential for contact with live wiring or down-lights. Ensure a minimum 50mm clearance from light fittings (check for safe distance with lighting supplier) and ensure 50mm clearance around hot flues. Plastic fixings should be used where any electrical componentry is in close vicinity of the installation materials. Do not use any metal fixings if working in close vicinity of electrical wiring.

RHINO FOAM 75THERMAL B R E A KTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Product Specification

Width 1350mm (+0.15m Flap)

Length 22.25m

Area 30m

Thickness 7.5 ± 1mm

Antiglare Reflectivity

95%

Silver Reflectivity

97%

Manufacturing Process:

Page 29: rhino range by thor building 2016

26

RHINO INSULSTEEL 65

Construction Type Heat Flow In Heat Flow Out

Steel Stud Frames Wall R-1.68 R-1.88

Brick Veneer Wall Insulsteel 65 R-1.85 R-2.11

Commercial Metal Roof Suspended Ceiling Insulsteel 65

Tilt Slab Concrete Offi ce Wall Insulsteel 65 R-1.9 R-2.1

Test Description Parameter

Corrosion REsistance AS/NZS 4859.1 Appen 1 Pass

Thermal Resistance AS/NZS 4859.1 ISO8302:1991 R0.216

Cone Calorimeter AS/NZS 3837 Group 1

Flammability AS 1530.2 Low (index ≤ 5)

Ignitability Flame Spread Heat Release Smoke Release Emittance

AS 1530.3 0/0/0/1

ASTM-E408 Refl ective E0.03Anti-glare E0.08

Vapour Transmission ASTM E96-2005 Medium

Dry Delamination AS/NZS 4201.1-1994 Pass

Wet Delamination AS/NZS 4859.1-2002 App.1 Pass

Shrinkage AS/NZS 4201.3-1994 Complies 0.3%

Duty AS 4200.1-1994 Table1. Complies Extra Heavy Duty

THERMAL PERFORMANCE*

PRODUCT TESTING

Product Information

Product Thickness 6.5mm (min)

Roll Size 22.25m x 1.350 (30m2)

Roll Weight 12kg

Roll Diameter 460mm

Refl ectance Antiglare 92%

Refl ective Side 97%

Max Span

For other Thermal Performance fi gures please consult our Technical Data Sheet.

*The R-Values shown were prepared and certifi ed by James M. Fricker MIEAust. CPEng. Consultant engineer in insulation to the BCA, the NCC 2011, and the insulation industry. These values are based upon product in an in service condition, and are accordance with AS/NZS

4859.1:2002.

Total R Values are based on product in-service conditions in accordance with AS/NZS 4859.1:2002/Amdt 1 (Dec 2006) including the alteration of insulation material R for temperature and derations of refl ective foil emittances due to dust as noted Where a cavity is sealed,

it is assumed there is no dust and n=hence emittance is not derated.

A chemically cross-linked polyethylene foam structure, Insulsteel 65 is laminated on both sides, with highly refl ective foil, with one side antiglare, making this product ideal as an Insulation as well as a Vapour Barrier and a Thermal Break.

*BCA Vol 1. Section J1.3(d) J1.5(b) (c) Vol 2.3.12.1.2(c) Roof 3.12.1.4 (b) Wall.

Rhino Insulsteel can also be used in other forms of construction such as tilt slab concrete walls, (with breather holes) brick veneer walls, and timber roofs. (Please consult our user and installation guide for further details).

PRODUCT DESCRIPTION

“Insulsteel 65” has a thermal break to comply with the BCA standards*

and the National Construction Code 2011, which requires an R0.20 thermal break for steel framed constructions to reduce thermal bridging

and conductivity between the building products.

R H I N O INSULSTEEL 65

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 30: rhino range by thor building 2016

27

RHINO FOIL RF-51 & RF-51B

d Satisfy BCA specifi cations and requirements for Refl ective Foil Laminates. d Complies with the specifi cations and requirements of AS/NZS 4200.1 for

“Pliable Building Membranes” which is a manual recognised by the BCA Part 3.5 Roof and Cladding.

d Low Flammability Index in accordance with AS 1530.2 < 5 d Satisfy BCA Part 3.7.1 Fire Hazard Properties. d Satisfy Health and Safety Regulations.

Recommended Applications and Properties

RF-51 RF-51BResidential Wall Insulation d d

Commercial Wall Insulation d d

Duty Medium Medium

Vapour barrier High Low

Emittance Refl ective Refl ective

Water barrier High Unclassifi ed

Flammability Index < 5 < 5 < 5

Tensile Strength Machine Direction (kN/M) min 9.5 min 9.5

Tensile Strength Lateral Direction (kN/M) min 6.0 min 6.0

Edge Tear Resistance Machine Direction (N) min 65 min 65

Edge Tear Resistance Lateral Direction (N) min 65 min 65

Water Vapour Transmission Rate (Ng/Ns) max 2 min 140

Emittance of Refl ective Face max 0.05 max 0.05

AvailabilityWidth 1350mm Length 30m Area 40.5m2

d d

Width 1350mm Length 60m Area 81m2d d

RP-91-HP (EHD)

RF-51 House WrapRF-51B Breather

RHINO FOIL USAGEIn all applications:• External cladding should be installed A.S.A.P• No contact is to be made with wet concrete or mortar• Store in dry area, weather proofed only after

installation• Shrinkage of up to 2% can be expected

In refl ective foil laminate applications:• Use only in accordance with AS/NZS 4200. 2 for

the “Installation Requirements for Pliable Building Membranes”

• Minimum of 20MM air space is recommended adjacent to refl ective foil face to achieve Maximum insulation values

PRODUCT INFORMATION

Rhino Foil Products are specifi cally manufactured

to the highest industry standards.

WALL INSTALLATION - Up to R1.1 may be added to the wall system when Rhino Foil RF-51 & RF-51B is

installed as wall cladding behind brick veneer/timber cladding. Our specialised manufacturing process

bonds together Aluminium Foil to a high strength

reinforcing Polymer Mesh using a fl ame retardant

adhesive. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce refl ective glare

problems when Rhino Foil is installed.

LIGHT WEIGHTSUPER STRENGTHHOUSE WRAPR F - 5 1RF-51BTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 31: rhino range by thor building 2016

28

RHINO WRAPRP-51 & RP-51B

d Satisfy BCA specifi cations and requirements for Refl ective Foil Laminates d Complies with the specifi cations and requirements of AS/NZS 4200.1 for

“Pliable Building Membranes” which is a manual recognised by the BCA Part 3.5 Roof and Cladding

d Low Flammability Index in accordance with AS 1530.2 <5 d Satisfy BCA Part 3.7.1 Fire Hazard Properties d Satisfy Health & Safety Regulations

Recommended Applications and Properties

RP-51 RP-51BResidential Wall Insulation d d

Commercial Wall Insulation d d

Duty Heavy Heavy

Vapour barrier High Low

Emittance Refl ective Refl ective

Water barrier High Unclassifi ed

Flammability Index < 5 < 5 < 5

Tensile Strength Machine Direction (kN/M) min 12.5 min 12.5

Tensile Strength Lateral Direction (kN/M) min 7.5 min 7.5

Edge Tear Resistance Machine Direction (N) min 80 min 80

Edge Tear Resistance Lateral Direction (N) min 80 min 80

Water Vapour Transmission Rate (Ng/Ns) max 2 min 140

Emittance of Refl ective Face max 0.05 max 0.05

AvailabilityWidth 1350mm Length 30m Area 40.5m2

d d

Width 1350mm Length 60m Area 81m2d d

Width 1500mm Length 30m Area 45m2d d

Width 1500mm Length 60m Area 90m2d d

RP-91-HP (EHD)

RP-51 Wall WrapRP-51B Breather

RHINO WRAP USAGEIn all applications:• External cladding should be installed A.S.A.P• No contact is to be made with wet concrete or mortar• Store in dry area, weather proofed only after

installation• Shrinkage of up to 2% can be expected

In refl ective foil laminate applications:• Use only in accordance with AS/NZS 4200.2 for

the “Installation Requirements for Pliable Building Membranes”

• Minimum of 20mm air space is recommended adjacent to refl ective foil face to achieve Maximum insulation values

PRODUCT INFORMATION

Rhino Wrap Products are specifi cally manufactured

to the highest industry standards.

WALL INSTALLATION - Up to R1.1 may be added to the wall system when

Rhino Wrap RP-51 & RP-51B is installed as wall cladding behind brick

veneer/timber cladding. Our specialised manufacturing

process bonds together Aluminium Foil to a high

strength reinforcing Polymer Mesh using a

fl ame retardant adhesive. Our Reinforcing Polymer

Mesh is purposely-treated blue in colour to reduce refl ective glare problems

when Rhino Wrap is installed.

HEAVY DUTYWALL WRAPR P - 5 1RP-51BTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 32: rhino range by thor building 2016

29

METAL ROOFING RP-51MR

d Satisfy BCA specifi cations and requirements for Refl ective Foil Laminates. d Complies with the specifi cations and requirements of AS/NZS 4200.1 for

“Pliable Building Membranes” which is a manual recognised by the BCA Part 3.5 Roof and Cladding.

d Low Flammability Index in accordance with AS 1530.2 < 5 d Satisfy BCA Part 3.7.1 Fire Hazard Properties. d Satisfy Health and Safety Regulations.

Recommended Applications and Properties

Residential & Commercial Roof Insulation d

Duty Heavy

Vapour barrier High

Emittance Refl ective

Water barrier High

Flammability Index < 5 < 5

Tensile Strength Machine Direction (kN/M) min 12.5

Tensile Strength Lateral Direction (kN/M) min 7.5

Edge Tear Resistance Machine Direction (N) min 80

Edge Tear Resistance Lateral Direction (N) min 80

Water Vapour Transmission Rate (Ng/Ns) max 2

Emittance of Refl ective Face max 0.05

AvailabilityWidth 1350mm Length 30m Area 40.5m2

Width 1350mm Length 60m Area 81m2

RP-51MR Metal Roofi ng

RP-51 Wall WrapRP-51B Breather

PRODUCT INFORMATION

Rhino Roofi ng Products are specifi cally manufactured

to the highest industry standards.

ROOF INSTALLATION - Up to R1.3 may be added to insulation system

when Rhino RP-51MR is installed. Our specialised manufacturing process

bonds together Aluminium Foil to a high strength

reinforcing Polymer Mesh using a fl ame retardant

adhesive. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce refl ective glare

problems when installing Roofi ng Products.

R H I N O M E TA LR O O F I N GR P - 5 1 M R

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

RHINO METAL ROOFING USAGEIn all applications:• External cladding should be installed A.S.A.P• No contact is to be made with wet concrete or mortar• Store in dry area, weather proofed only after

installation• Shrinkage of up to 2% can be expected

In refl ective foil laminate applications:• Use only in accordance with AS/NZS 4200. 2 for

the “Installation Requirements for Pliable Building Membranes”

• Minimum of 20MM air space is recommended adjacent to refl ective foil face to achieve Maximum insulation values

• 40MM sag between trusses is recommended when using Rhino RP-51MR

• For use in enclosed structures

NOTE: Use in cold temperature climates (daytime < 5°C) requires roof to be well ventilated and moist air from within the dwelling to be

exhausted out into the atmosphere.

Page 33: rhino range by thor building 2016

30

RHINO ROOFINGRP-61

d Satisfy BCA specifi cations and requirements for Refl ective Foil Laminates d Complies with the specifi cations and requirements of AS/NZS 4200.1 for

“Pliable Building Membranes” which is a manual recognised by the BCA Part 3.5 Roof and Cladding.

d Low Flammability Index in accordance with AS 1530.2 < 5 d Satisfy BCA Part 3.7.1 Fire Hazard Properties. d Satisfy Health and Safety Regulations. d Complies with AS/NZS 4040.4 Impact Resistance (Sandbag Test).

In all applications:• External cladding should be

installed A.S.A.P• No contact is to be made with wet

concrete or mortar• Store in dry area, weather proofed

only after installation• Shrinkage of up to 2% can be

expected

In refl ective foil laminate applications:• Use only in accordance with

AS/NZS 4200. 2 for the “Installation Requirements for Pliable Building Membranes”

• Minimum of 20MM air space is recommended adjacent to refl ective foil face to achieve Maximum insulation values

• 40MM sag between trusses is recommended when using Rhino Roofi ng RP-61

• For use in enclosed structures

Recommended Applications and Properties

Tensile strength - Cladding High

Durability - Cladding High

Impact Resistant - Cladding High

Residential & Commercial Roof Insulation d

Flame Retardant - Cladding d

Duty Heavy

Vapour Barrier High

Emittance Refl ective

Water Barrier High

Flammability Index < 5 < 5

Tensile Strength Machine Direction (kN/M) min 12.5

Tensile Strength Lateral Direction (kN/M) min 7.5

Edge Tear Resistance Machine Direction (N) min 80

Edge Tear Resistance Lateral Direction (N) min 80

Water Vapour Transmission Rate (Ng/Ns) max 2

Emittance of Refl ective Face max 0.05

Availability

Width 1500mm Length 30m Area 45m2

RHINO ROOFING RP-61 USAGE

RP-61(HD)RP-81(EHD)

RP-51 Wall WrapRP-51B Breather

PROTECTIVE ROOF/VAPOUR BARRIER - Added protection against stormwater, condensation and wind is achieved in roof structures when applied under roof tiles. Rhino Roofi ng RP-61 can also be a very effective vapour barrier when sealed with recommended tapes.

PRODUCT INFORMATION

Rhino Roofi ng Products are specifi cally manufactured

to the highest industry standards.

R H I N O ROOFINGR P - 6 1THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

PRODUCT INFORMATIONROOF INSULATION - Up to R1.0 (downward heat fl ow) may be added to the insulation System R-Value when Rhino Roofi ng RP-61 is installed adjacent to an airspace in tiled roof structures. Our specialist manufacturing process bonds together Aluminium Foil and high density Kraft Paper that is then laminated with a high strength reinforcing Polymer Mesh. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce refl ective glare problems when Rhino Roofi ng is installed. To achieve and ensure maximum protection is attained, Flame Retardant Adhesive is applied during the fi nal process of manufacture in all Rhino Roofi ng Products.

ENERGY EFFICIENCY - Rhino Roofi ng RP-61 provides effective reductions in greenhouse gas emissions when used in an insulation agent in buildings. Preferred seasonal gains in required temperatures are assured.

LIGHT REFLECTIVITY - Gains of up to 40% can be obtained by using Rhino Roofi ng RP-61 as an exposed internal roof lining. Effi ciencies in lighting loads are also evident. Conforms to AS/NZS 4859.1-2002.

Page 34: rhino range by thor building 2016

31

HIGH PERFORMANCE RP-91-HP-15

d Satisfy BCA specifi cations and requirements for Refl ective Foil Laminates d Complies with the specifi cations and requirements of AS/NZS 4200.1 for

“Pliable Building Membranes” which is a manual recognised by the BCA Part 3.5 Roof and Cladding.

d Low Flammability Index in accordance with AS 1530.2 < 5 d Satisfy BCA Part 3.7.1 Fire Hazard Properties. d Satisfy Health and Safety Regulations. d Complies with AS/NZS 4040.4 Impact Resistance (Sandbag Test).

In all applications:• External cladding should be

installed A.S.A.P• No contact is to be made with wet

concrete or mortar• Store in dry area, weather proofed

only after installation• Shrinkage of up to 2% can be

expected

In refl ective foil laminate applications:• Use only in accordance with

AS/NZS 4200. 2 for the “Installation Requirements for Pliable Building Membranes”

• Minimum of 20MM air space is recommended adjacent to refl ective foil face to achieve Maximum insulation values

• 40MM sag between trusses is recommended when using Rhino Roofi ng RP-91

• For use in enclosed structures

NOTE: Use in cold temperature climates (daytime < 5°C) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere.

Recommended Applications and Properties

Tensile strength - Cladding High

Durability - Cladding High

Impact Resistant - Cladding High

Residential & Commercial Roof Insulation d

High Wind Load Protection d

Acoustic Performance Agent d

Flame Retardant - Cladding d

Duty Extra Heavy

Vapour Barrier High

Emittance Refl ective

Water Barrier High

Flammability Index < 5 < 5

Tensile Strength Machine Direction (kN/M) min 13.0

Tensile Strength Lateral Direction (kN/M) min 10.5

Edge Tear Resistance Machine Direction (N) min 90

Edge Tear Resistance Lateral Direction (N) min 90

Water Vapour Transmission Rate (Ng/Ns) max 2

Emittance of Refl ective Face max 0.05

AvailabilityWidth 1500mm Length 30m Area 45m2

RHINO ROOFING (EHD) USAGE

RP-91-HP (EHD)

RP-51 Wall WrapRP-51B Breather

PRODUCT INFORMATION

Rhino Roofi ng Products are specifi cally manufactured

to the highest industry standards.

R H I N O ROOFINGRP-91 HIGHPERFORMANCE

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

PRODUCT INFORMATIONROOF INSULATION - Up to R1.0 (tiled) & R1.3 (Metal) may be added to insulation protection when Rhino Roofi ng RP-91-HP is installed within an airspace in roof structures. Our specialised manufacturing process laminates Aluminium Foil with a high strength reinforcing Polymer Mesh.

ENERGY EFFICIENCY - Rhino Roofi ng RP-91-HP contributes to effective reductions in greenhouse gas emissions when used as an insulation agent in buildings.

LIGHT REFLECTIVITY - Gains of up to 40% can be obtained by using Rhino Roofi ng RP-91 as an exposed internal roof lining. Effi ciencies in lighting loads are also evident. Conforms to AS/NZS 4859.1-2002.

PROTECTIVE ROOF/VAPOUR BARRIER - Added protection against stormwater, condensation and wind is achieved in roof structures when applied under roof tiles or metal roofs. Rhino Roofi ng RP-91-HP can also be a very effective vapour barrier when sealed with recommended tapes.

Page 35: rhino range by thor building 2016

32

RP-51-WR

RP-51-WR

MULTI PURPOSERP-51-WR

d Satisfy BCA specifi cations and requirements for Refl ective Foil Laminates. d Complies with the specifi cations and requirements of AS/NZS 4200.1 for

“Pliable Building Membranes” which is a manual recognised by the BCA Part 3.5 Roof and Cladding.

d Low Flammability Index in accordance with AS 1530.2 < 5 d Satisfy BCA Part 3.7.1 Fire Hazard Properties. d Satisfy Health and Safety Regulations.

Recommended Applications and Properties

Residential & Commercial Wall &Roof Insulation d

Duty Heavy

Vapour barrier High

Emittance Refl ective

Water barrier High

Flammability Index < 5 < 5

Tensile Strength Machine Direction (kN/M) min 12.5

Tensile Strength Lateral Direction (kN/M) min 7.5

Edge Tear Resistance Machine Direction (N) min 80

Edge Tear Resistance Lateral Direction (N) min 80

Water Vapour Transmission Rate (Ng/Ns) max 2

Emittance of Refl ective Face max 0.05

AvailabilityWidth 1350mm Length 30m Area 40.5m2

Width 1350mm Length 60m Area 81m2

PRODUCT INFORMATION

Rhino Wrap Products are specifi cally manufactured

to the highest industry standards.

WALL INSTALLATION - Up to R1.1 may be added to the wall system when

Rhino Multi Purpose Wrap is installed as wall cladding behind brick veneer/timber

cladding.

ROOF INSTALLATION - Up to R1.3 may be added to insulation system when

Rhino Multi Purpose Wrap is installed. Our specialised

manufacturing process bonds together Aluminium

Foil to a high strength reinforcing Polymer Mesh using a fl ame retardant

adhesive. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce refl ective glare

problems when Rhino Multi Purpose wrap is

installed.

R H I N O M U LT IP U R P O S EWALL & METAL ROOF

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

RHINO MULTI PURPOSE WRAP USAGEIn all applications:• External cladding should be installed A.S.A.P• No contact is to be made with wet concrete or mortar• Store in dry area, weather proofed only after

installation• Shrinkage of up to 2% can be expected

In refl ective foil laminate applications:• Use only in accordance with AS/NZS 4200. 2 for

the “Installation Requirements for Pliable Building Membranes”

• Minimum of 20MM air space is recommended adjacent to refl ective foil face to achieve Maximum insulation values

• 40MM sag between trusses is recommended when using Rhino RP-51-WR

• For use in enclosed structures

Page 36: rhino range by thor building 2016

33

TILE & METAL ROOFINGRP-51-TM

d Satisfy BCA specifi cations and requirements for Refl ective Foil Laminates. d Complies with the specifi cations and requirements of AS/NZS 4200.1 for

“Pliable Building Membranes” which is a manual recognised by the BCA Part 3.5 Roof and Cladding.

d Low Flammability Index in accordance with AS 1530.2 < 5 d Satisfy BCA Part 3.7.1 Fire Hazard Properties. d Satisfy Health and Safety Regulations.

Recommended Applications and Properties

Residential & Commercial Wall &Roof Insulation

d

Duty Heavy

Vapour barrier High

Emittance Refl ective

Water barrier High

Flammability Index < 5 < 5

Tensile Strength Machine Direction (kN/M) min 12.5

Tensile Strength Lateral Direction (kN/M) min 7.5

Edge Tear Resistance Machine Direction (N) min 80

Edge Tear Resistance Lateral Direction (N) min 80

Water Vapour Transmission Rate (Ng/Ns) max 2

Emittance of Refl ective Face max 0.05

AvailabilityWidth 1350mm Length 30m Area 40.5m2

Width 1500mm Length 20m Area30m2

RP-51-TM TILE & METAL ROOFING

RP-51 Wall WrapRP-51B Breather

RP-51-TM TILE & METAL ROOFING

RP-51 Wall WrapRP-51B Breather

PRODUCT INFORMATION

Rhino Roofi ng Products are specifi cally manufactured

to the highest industry standards.

ROOF INSTALLATION - Up to R1.3 may be added to insulation system when

RP-51-TM is installed. Our specialised manufacturing

process bonds together Aluminium Foil to a high

strength reinforcing Polymer Mesh using a

fl ame retardant adhesive. Our Reinforcing Polymer Mesh is purposely treated blue in colour to reduce refl ective glare problems when installing Roofi ng

Products.

R H I N O TILE & METALROOFING RP-51TM

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

RHINO TILE & METAL ROOFING USAGEIn all applications:• External cladding should be installed A.S.A.P• No contact is to be made with wet concrete or mortar• Store in dry area, weather proofed only after installation• Shrinkage of up to 2% can be expected

In refl ective foil laminate applications:• Use only in accordance with AS/NZS 4200. 2 for

the “Installation Requirements for Pliable Building Membranes”

• Minimum of 20MM air space is recommended adjacent to refl ective foil face to achieve Maximum insulation values

• 40MM sag between trusses is recommended when using Rhino RP-51-TM

• For use in enclosed structures

NOTE: Use in cold temperature climates (daytime < 5°C) requires roof to be well ventilated and moist air from within the dwelling to be exhausted out into the atmosphere.

Page 37: rhino range by thor building 2016

34

RHINO BLANKET FACING (HEAVY & EXTRA HEAVY DUTY)

d Satisfy BCA specifi cations and requirements for Refl ective Foil Laminates. d Complies with the specifi cations and requirements of AS/NZS 4200.1 for

“Pliable Building Membranes” which is a manual recognised by the BCA Part 3.5 Roof and Cladding.

d Low Flammability Index in accordance with AS 1530.2 ≤ 5 d Satisfy BCA Part 3.7.1 Fire Hazard Properties. d Satisfy Health and Safety Regulations.

APPLICATIONDesigned for application under metal, fi bre cement, and concrete roof cladding Thor’s Blanket Facing eliminates the problems associated with condensation build up on the underside of the roof cladding. The refl ective foil face faces down toward the air space under the roof and prevents airborne moisture from reaching the surface of the roof cladding.

NOTE - Use in cold temperature climates (daytime <5oC) requires roof to be well ventilatedand moist air from within the dwelling to be exhausted out into the atmosphere.

FACING OPTIONS - The Duty Rating, Colour and Material Finish of the blanket facing can be varied to suit your application.

Colour Gloss White Gloss Silver-Grey Matt Dark Blue

Duty Extra Heavy Heavy HeavyWidth 1350 1350 1350

Residential & Commercial Insulation d d d

Vapour barrier High High High

Emittance Refl ective Refl ective Refl ective

Water barrier High High High

Flammability Index Low (≤5) Low (≤5) Low (≤5)

UV treated non refl ective face (not direct sunlight) d d d

Tensile Strength Machine Direction (kN/m) min 13.0 min 12.5 min 12.5

Tensile Strength Lateral Direction (kN/m) min 10.5 min 7.5 min 7.5

Edge Tear Resistance Machine Direction (N) min 90 min 80 min 80

Edge Tear Resistance Lateral Directions (N) min 90 min 80 min 80

Water Vapour Transmission Rate (Ng/Ns) max 2 max 2 max 2

Emittance of Refl ective Face max 0.05 max 0.05 max 0.05

PRODUCT INFORMATION

Thor’s Blanket Facing is made with a high strength

polywoven fabric facing which is applied to a

glasswool blanket whilstother products commonly

use a double sided foil with fi bre mesh for the facing.

The polywoven fabric provides the additional

benefi ts of:

• Outstanding tensile and tear strength.

• Unrolls more easily right the way to the end of the roll.

• An excellent visible surface fi nish.

R H I N O BLANKETF A C I N GTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 38: rhino range by thor building 2016

35

RHINO PIR BOARD

RHINO PIR BOARDRhino PIR Board is an Australian made and tested prefabricated heat insulating elements for a variety of applications in the building and domestic industry, which consists of fl exible cover sheets connected with a high bond to a cored polyisocyanurate foam. The cover sheets can be made of different materials, such as aluminium foil, mineral and glass fl eeces and paper. The boards are available in thicknesses between 25 to 150 mm and lengths up to 10 meters. The polyisocyanuratefoam, a three-dimensionally networked thermoset, is made from synthetic polymers, which are combined with a CFC-and HCFC free blowing agent (zero CCP) in an expansion process to form microscopic cells throughout the material. Our laminates offer a combination of structural properties and capacities of cost-effective system building and energy conservation at minimal weight along with low water absorption, thermal and acoustic insulation and good chemical resistance at good aging stability.

Rhino PIR Board sets a new standard in PIR insulation system as it offers a more cost effective, high performance, zero -ozone depleting PIR insulated solution. Rhino PIR Board is available with facings of, bright silver foil, craft paper and white fi breglass fi nish. Rhino PIR Board has great thermal properties which will save energy for heating, cooling and lighting. Its acoustic properties will also help in reducing noise. Rhino PIR Board is available in thicknesses of 25mm through to 100mm in 5mm increments.

Core PIR (Fire-retardant Polyisocyanurate)Width(mm) 1200Thickness (mm) 25 through to 100 in 5mm incrementsLength (mm) 2400Interior Facing Skin Silver Foil, Craft Paper, White FibreglassExterior Facing Skin Silver Foil, Craft Paper, White Fibreglass

INSTALLATION OF RHINO PIR BOARD AS A CONCRETE SOFFIT:Where Rhino PIR Board is exposed to external wind loads ensure fasteners chosen for the install are in conjunction with AS/NZS 1170.2 - Wind load standards.

1. Place Rhino PIR Board against the underside of the concrete slab.2. Use fasteners that incorporate washers with a head diameter of not less than 35mm diameter

(for example: using Hilti X-IE6 Insulation fasteners) boards can either be in a square or staggered pattern. Begin to affi x the boards to the underside of the concrete in accordance with manufacturer’s guidelines.

3. Continue fi xing each board following the below minimum fi xing layout, each board that is 2400mm x 1200mm must be fi xed with no less than 8 fasteners. For the fasteners around the perimeter of the board must be between 50mm and 150mm from the edge of the board.

4. Repeat the above steps to install the Rhino PIR Board in a continuous layer on the underside of the concrete slab.

5. Tape all joins with a minimum 96mm wide Insulation tape. Following the manufacturer’s installation guidelines. Ensure to seal around the perimeter and joins, this will prevent air fl ow between any air cavities formed below or above the boards.

Fastener confi guration, B pef 2400mm x 1200mm board - 2.78 fi xings Im’

APPLICATIONS INCLUDE

• Soffi t Board• Cavity Wall Board• All Purpose (AP) Framing

Board

R H I N O PIR BOARDTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 39: rhino range by thor building 2016

36

RHINO PIR BOARD

Panel Properties

Panel Thickness (mm)

25 40 50 60 65

Mass (kg/m3)** 1.3 1.9 2.2 2.8 3

Thermal Performance

(based on NATA endorsed k=0.020355 W/mK at 23C)

Initial ‘U’ Value (W/m2K)

0.81 0.51 0.41 0.34 0.31

Initial ‘R’Value (m2K/W)

1.23 1.97 2.46 2.95 3.19

Panel Properties

Panel Thickness (mm)

70 75 80 90 100

Mass (kg/m3)** 3.2 3.3 3.6 3.7 3.8

Thermal Performance

(based on NATA endorsed k=0.020355 W/mK at 23C)

Initial ‘U’ Value (W/m2K)

0.29 0.27 0.25 0.23 0.2

Initial ‘R’Value (m2K/W)

3.44 3.68 3.93 4.42 4.91

NOTES:• Taken from NATA endorsed test report and using ISO 10456, table A.4 for the calculation of k-values at 23 deg C••May vary depending on facing materials used. Typical value based on boards being manufactured with Aluminium Foil external facing. Craft Paper on Internal facing.

Please fi nd the Installation Guide for:Soffi t Board - Cavity Wall Board - All Purpose (AP) Framing Board on our website: www.thorbuilding.com.au

RHINO PIR BOARD - USE IN CONCRETE WALL SYSTEMSystem calculation assumes incorporation of 100mm concrete, 70mm thick RHINO PIR Board insulation (refl ective surface facing into the airspace below).

Concrete wall –Rhino PIR Board insulation directly fi xed to concrete Wall

(no internal lining) RT 2.9

System calculation assumes incorporation of 150mm concrete, 55mm thick Rhino PIR Board insulation (refl ective surface

facing internally).

Concrete wall –Rhino PIR Board insulation directly fi xed to concrete Wall

(with internal lining) RT 2.8

System calculation assumes incorporation of 150mm concrete, 40mm thick Rhino PIR Board insulation, 24mm refl ective airspace (created using steel batten),

10mm plasterboard lining.

APPLICATIONS INCLUDE

• Soffi t Board• Cavity Wall Board• All Purpose (AP) Framing

Board

R H I N O PIR BOARDTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 40: rhino range by thor building 2016

37

RHINO PIR BOARD

Brick Veneer Wall –Rhino PIR Boardinsulation positioned within

wall frame RT 2.8

System calculation assumes incorporation of 110mm clay brick, 45mm airspace, 35mm thick Rhino PIR insulation, 55mm refl ective

air space, 10mm plasterboard lining.

Brick Veneer Wall –Rhino PIR Boardinsulation positioned towards internal side

of wall frame RT 2.9

System calculation assumes incorporation of 110mm clay brick, 45mm airspace, 90mm refl ective airspace, 35mm Rhino PIR Board

insulation, 10mm plasterboard lining.

Brick Veneer Wall –Rhino PIR Boardinsulation positioned towards external

side of wall frame RT 2.9

System calculation assumes incorporation of 110mm clay brick, 20mm refl ective

airspace, 25mm thick Rhino PIR insulation, 90mm refl ective airspace,

10mm plasterboard lining.

Cavity brickwall –Rhino PIR Boardinsulation positioned adjacent

to the inner leaf RT 2.8

System calculation assumes incorporation of 110mm clay brick, 20mm refl ective airspace, 35mm thick Rhino PIR Board

insulation, 110mm clay brick.

RHINO PIR BOARD - USE IN BRICK VENEER WALL SYSTEMSystem calculation assumes incorporation of 110mm clay brick, 45mm airspace, 35mm thick RHINO PIR Board insulation, 55mm refl ective air space, 10mm plasterboard lining

APPLICATIONS INCLUDE

• Soffi t Board• Cavity Wall Board• All Purpose (AP) Framing

Board

R H I N O PIR BOARDTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 41: rhino range by thor building 2016

38

RHINO LAGGING

Product/density (kg/m2) Thickness (mm) Roll Size (mm) m2/Roll

5 25 5m x 1350mm 6.75

PHYSICAL CHARACTERISTICS

SOUND TRANSMISSION LOSS

AS1530.3 EARLY FIRE HAZARD PROPERTIES OF MATERIALS

MAXIMUM OPERATING TEMPERATURE

INSTALLATION

PRODUCT DESCRIPTION AND TYPICAL APPLICATIONSRhino’s Pipe Acoustic Lagging is recomended for reducing noise generated by rainwater, soil or waste pipes. It is typically used to wrap PVC or metal pipes in residential or multi-residential buidlings, as well as in commercial buildings such as cinemas, auditoriums and concert halls. Pipe Acoustic Lagging is a combination of a loaded polymer barrier adhered to convoluted acoustic foam with an outer layer of Aluminium Foil Tri-Laminate.

Pipe Acoustic Lagging addresses the Building Code of Australia (Part F5) requirements that the sound insulation performance fl oors and walls in Class 2 and 3 multi-residential buildings shall not be adversely affected by pipe or service penetrations.

The BCA recognises the common problem of noise intrusion from waste pipes and specifi es minimum standards of noise separateion between such pipes and habitable room spaces (bedrooms, lounges, dining and family rooms) and non habitable room spaces (bathrooms, kitchens and laundries).

In these cases, Pipe Acoustic Lagging must be applied to pipes adjacent to ceiling penetrations such as air conditioning ducts, vents, downlights and exhaust fans. Pipe Acoustic Lagging correctly installed within a ‘deemed to satisfy’ construction, meets these requirements.

Pipe Acoustic Lagging exhibits the following characteristics when tested in accordance with AS1530.3

Operating temperature (maximum continuous) 80°COperating temperature (maximum intermittent) 100°C

Pipe Acoustic Lagging can be cut from rolls to fi t the required PVC waste pipe diameter. All butt joins must be taped. Reinforced aluminium foil tape is recommended for this application. Reinforced aluminium foil tape must be a minimum of 48mm in width and preferably 72mm wide. As well as taping all longitudinal and circumferential joins, it is recomemended that a band of tape be applied midway along each section to overcome sagging and to ensure Pipe Acoustic Lagging is held in close contact with the pipe. Pipe Acoustic Lagging is easily cut with a sharp knife.

PRODUCT DESCRIPTION

Rhino Pipe Acoustic Lagging. Acoustic Insulation

for waste pipes.

SPECIFICATION NOTESWhen specifying state

the following:• Product name

Rhino Pipe Acoustic Lagging

• Density-5kg/m2• State elements to be

insulated:eg. Acoustically insulate all sewer andrainwater pipes installed behind walls and ceiling linings.

R H I N O LA G G I N GTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 42: rhino range by thor building 2016

39

RHINO ROCKWOOLFIRE SEAL BATTS

Mean Temp °C 50 100 150 200 250 300

K value W/m.K 0.038 0.044 0.052 0.062 0.074 0.088

PRODUCT PERFORMANCE PROPERTIESFusion Temperature > 1120°C - Melting point to fl ow of Roxul® Stonewool fi bre.

Thermal Conductivity (typical data)Tested in accordance with DIN 52612

Fire Resistance Fire resistance performance was tested by CSIRO in accordance with A.S 1530 Part 4 (Fire resistance tests of elements of building construction), and A.S. 4072-1992 (Components for the protection of openings in fi re separating elements - Service penetrations and control joints. As a result of this testing a 200mm thick specimen of Roxul Party Wall Fire Stop achieved:

INTEGRITY 4HOURSINSULATIONS 4HOURS

FireRoxul® Stonewool Party Wall Fire Stop is non- combustible when tested according to international standards e.g. ASTM E-136-82, DIN 4102, BS476 Pt4-1970, ISO 1182 and IMO A 799 (19).

Corrosion Resistance - Chemical Neutrality:Roxul® Stonewool base mineral wool is chemically neutral and will neither cause nor promote corrosion.

Corrosion Resistance - Water Leachable Chlorides:Roxul® Stonewool base mineral wool has a very low content of water leachable chloride, approximately 6ppm, so it can be safely used on austenitic stainless steel. Meets the requirements for use over stainless steel in accordance with ASTM C795 and of “AS-Quality” of AGI Q135.

Moisture Resistance - Vapour Diffusion:Water vapour diffusion resistance factor of µ = 1.3. This low value means that water can pass through and cool without condensing.

Moisture Resistance - Absorption from the air:Roxul® Stonewool absorbs very little water from the air. Tests show at relative humidity of 90% for 30 days the hygroscopic water content is around .004 volume per cent. The water vapour absorption (vapor sorption) in accordance with ASTM C110 4/C 110 M is + 0.02% (vol).

Specifi c Heat:Roxul® Stonewool specifi c heat factor is 0.84 kJ/kg per degree centigrade.

Calorifi c Value:Roxul® Stonewool has a low organic matter content giving a low caloric value of around 600 kJ/kg.

Biological Properties:Roxul® Stonewool contains no nutrients and therefore provides no basis for growth of fungi, moulds or bacteria, nor does it attract insects, rodents or vermin.

DurabilityRoxul® Stonewool mineral wool has been proven in services for over 50 years in all types of exposure and as such will give effective protection for the lifetime of the equipment they insulate.

NOTE: The above are declared thermal conductivity performances and are based on the mean value of many Roxul laboratory and independent testing authority test results.

Thickness (mm) Dimension (mm) Pieces per Pack Pack Contents (m2)

100 1200x168 10 2.016

PRODUCT DESCRIPTION

Rhino Rockwool Fire Seal Batts have been

developed to provide up to 4 hours fi re-resistance at the junctions between

the top of party walls and roof structures, and to the diverse junctions of compartment walls

and fl oors. It is a highly robust mineral wool that remains dimensionally

stable at extremely high temperatures.

R H I N O RO C KWO O L

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 43: rhino range by thor building 2016

40

RHINO ROCKWOOLFIRE SEAL BATTS

Compatibility:Roxul® Stonewool mineral wool is compatible with all materials which it is likely to come into contact in normal industrial and building applications.

Environment:Roxul® Stonewool mineral wool presents a very effective ecological profi le in all elements of manufacture, recycling use, service life and energy effi ciency of material. No CFC’s or HCFC’s are used in its manufacture.

Installation Instructions:1. Party Wall Fire Stop must be fi tted as a rectangular piece, accurately butt jointed and compressed

by at least 5% vertically in thickness.2. Party Wall Fire Stop must be fi tted to give a tight and accurate fi t, closely following the profi le of

the gap.3. Appraisal documents permit 1 or 2 layers to be used. Single layer fi re stopping will always

be preferred. However, double layer methods are acceptable where there is no other practical alternative. If used, 2 layers should be installed simultaneously.

4. Expansion gaps can be fi re-stopped with Fire Stop Fire Damper Strip materials. The compression levels should be observed in due regard to expansion movement.

5. Installers may fi nd simple smooth ‘slip-plates’ of benefi t in installing Party Wall Fire Stop materials over rough surfaces.

HEALTH & SAFETYRhino Rockwool Fire Seal Batts are NOT CLASSIFIED as HAZARDOUS according to NOHSC criteria as a consequence of the following events and conclusions about the health effects of long term occupation exposure to mineral wool insulation products.

• Over 50 years of extensive health research on Stonewool products in Europe has resulted in the scientifi c conclusion that there are no long term health problems from using Stonewool.

• In March 1995 the UK Health and Safety Executive concluded that Stonewool should not be classifi ed as a potential carcinogen.

• Under note Q of the National Occupational health and Safety Commission (NOHSC) publication “List of Designated Hazardous Substances” (NOHSC; 1005- 1999) the classifi cation of NON-CARCINOGENIC is to apply.

• Under the European Union Criteria set out in 67/548/EEC a classifi cation of CARC, Cat O applies, ie; ”Not classifi able for carcinogenicity.”

• Under World Health Organisation (WHO) and its Monographs Programme of the International Agency for Research on Cancer (IARC) it has been concluded that, Stonewools are now considered not classifi able as to carcinogenicity to humans (Group 3), It recommended that for the handling and installation of Roxul® Stonewool the internationally recognized Material Safety Data Sheet be followed; These are readily available from Australasian Insulation Supplies Pty Ltd.

PRODUCT DESCRIPTION

Rhino Rockwool Fire Seal Batts have been

developed to provide up to 4 hours fi re-resistance at the junctions between

the top of party walls and roof structures, and to the diverse junctions of compartment walls

and fl oors. It is a highly robust mineral wool that remains dimensionally

stable at extremely high temperatures.

R H I N O RO C KWO O L

THE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 44: rhino range by thor building 2016

41

SAFETY MESH

Original roofi ng mesh that was developed and tested to provide the industry standard described in the AS/NZS 4389 and ALL State Code of Practices for Safe Working on Roofs.

Roofi ng Mesh consists of 2mm galvanised wire with a tensile strength exceeding 450mpa. The longitudinal wires are spaced at 150mm centres with cross wires spaced at 300mm centres. The rolls are available either 1800mm, 2250mm or 2400mm wide and are supplied in standard 50metre rolls or cut to the length of the roof run.

The product is also available PVC-coated for use in corrosive environments.

CAN BE USED ON THE FOLLOWING ROOFS

SPECIFICATIONS

1800 Wide 2250 WIde 2400 Wide PVC1800

Weight per 50m 24kg 29kg 31kg 28kg

Weight per metre 0.48kg 0.58kg 0.62kg 0.56kg

Sqm per roll 90 112.5 120 90

Sqm with one lap 82.5 105 112.5 82.5

Sqm with double lap 75 97.5 105 75

50m rolls per pallet 25 25 25 16

d Factories d Shopping Centres d Hospitals/Aged Care Facilities d Sheds d Warehouses d Schools d Offi ce Block

PRODUCT INFORMATION

Original roong mesh that was developed and tested

to provide the industry standard described in the

AS/NZS 4389 and ALL StateCode of Practices for Safe

Working on Roofs.

SAFETY M E S HTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 45: rhino range by thor building 2016

42

ROOF RAZOR

Raise the roof or create an open space between two planes with the Roof Razor. Suitable for roofi ng, walling and fl ooring this versatile and robust solution has endless possibilities. The unique design will also slice through glass wool insulation allowing it to recover to its full nominal thickness.

The unique design of the legs means that the screws not only come pre-loaded, but are also encased within the legs. The legs guide the fi xings to the purlinand stop the polyester fi bres from spinning or being entangled around the screws.

Key advantages of the Roof Razor system

d 68.4mm surface width d Horizontally opposed fi xing points provide a strong and d Compatible with all brands of roofi ng clips, and all roofi ng profi les d One piece system d 1200mm length to suit building blanket width d Suitable for walling d Supplied fully assembled and pre-loaded with screws d Tiny contact areas reduce loss of R-value to less than 1% d Legs are sharp enough to cut through the wool like a knife

THERMAL PERFORMANCEVoids create thermal bridgingNo Fully compressed wool, total loss of R-Value less than 1%Signifi cantly increased R-value when using the Roof Razor System

... and it won’t loosen over time

PRODUCT INFORMATION

Raise the roof or create an open space between two

planes with the Roof Razor.

R O O FRA Z O RTHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 46: rhino range by thor building 2016

43

DOWNLIGHT CONE

THOR Downlight Cone Cover complies with:

AS/NZS 3000:2007 Clause 4.5.2.3 (c) Provision of required clearances from combustible and thermal insulation materialAS/NZS 60598-1:2003 Clause 12.4 Thermal TestAS/NZS 60598-2-2:2001 Clause 13.3 Resistance to fl ame and ignition (650oC Glow-wire test)

Additional testing of resistance to fl ame and ignition (960 C Golow-wire and Needle fl ame)

d Fire Retardant Nylon

PERFORMANCE

MATERIAL

DOWNLIGHTC O N ETHE ULTIMATE PROTECTION

Proudly Manufactured byThor Building Products P/L

November 2015

{ 1300 880 828

N [email protected]

i www.thorbuilding.com.au

Page 47: rhino range by thor building 2016

by THOR BUILDING PRODUCTS

Page 48: rhino range by thor building 2016

by RHINO INDUSTRIAL COATING SOLUTIONS

THOR is a trusted brand in the building industry known for Quality Products, Service & Support.Proudly Owned & Manufactured in Australia for 15 years

www.rhinoindustrialcoating.com.au

Page 49: rhino range by thor building 2016

Rhino Industrial Coating Solutions Pty Ltd HEAD OFFICE293 Earnshaw Rd Northgate QLD 4013 T: 1300 880 828F: 07 3219 6833E: [email protected]: www.rhinoindustrialcoating.com.au ABN 52 169 684 566

Page 50: rhino range by thor building 2016

THOR is a trusted brand in the building industry known for Quality Products, Service & Support.Proudly Owned & Manufactured in Australia for 15 years

CLEAR SEALERHigh Solids Preparation & Application Guide

Section 1SEALER

Concrete sealer and tint

Section 2ANTI-GRAFFITI

Anti graffi ti coatings

Section 3THINNERS

Thinners & Reducers

Section 4TWO PARTS

Two part coatings

Section 5TREATMENTS

Other surface treatments

by RHINO INDUSTRIAL COATING SOLUTIONS

Page 51: rhino range by thor building 2016

1

by RHINO INDUSTRIAL COATING SOLUTIONS

CLEAR SEALERS – HIGH SOLIDS PREPARATION & APPLICATION GUIDE

SURFACE PREPARATION• All surfaces must be clean – all contaminants including dirt, dust, grease, oil, curing compounds, cement laitance, airborne pollutants,

mildew, mould etc must be removed using compatible chemical cleaning product and / or mechanical process. If surfaces are not clean, sealer adhesion and fi nal fi nish will be compromised. Poor surface adhesion may lead to delamination of the sealer, indicated by surface whitening / fl aking or peeling of the coating.

• If surface has been ground – all dust and laitance must be removed by vacuum and pressure wash / wet vac.• If acid etching has taken place, acid must be neutralised before sealer is applied. If neutralisation does not take place, acid will

continue to attack and weaken the substrate surface. This will compromise the adhesive strength of the sealer. Residual acid may also “shock” sealer resins, delivering a white powdery fi nish to water based sealers and an uneven blotchy fi nish to solvent based sealers. Acid neutralisation may be achieved by treating the area with a 500g bicarbonate of soda: 9L water solution, followed by a pressure wash.

• All surfaces must be sound – although clear sealers will bind surfaces to a certain extent, they are not engineered for use as surface hardeners. Both new and old concrete surfaces will exhibit varying degrees of porosity. High porosity areas will absorb sealer more readily, resulting in a dull appearance. Additional coats of sealer will deliver a uniform fi nish in these situations.

• All surfaces must be dry – a moisture test is required 100% of the time to ascertain if the substrate is dry enough to seal. Electronic moisture meters are recommended, however a simple test may be performed as per below.

• Simple moisture test - place a 300 x 300 mm piece of black plastic / rubber mat on the area to be sealed at the hottest part of the day. Leave for 2 hours and remove, if any condensation is present on the under-side of the plastic, or the substrate has darkened, then it is too wet to seal. Be patient, allow to dry further and repeat test until no moisture is detected.

• If area has been previously sealed, ensure that this coating is compatible with the sealer to be used. If sealer application is recoating existing compatible sealer, ensure that fi nal fi lm thickness achieved does not compromise the breathability of the substrate. If in doubt, remove existing sealer chemically or mechanically.

Important Note: If concrete slab has been ground, the heat generated will expel moisture. If the slab is outside and left overnight, as it cools it will act like a sponge and absorb moisture from the damp night air. If the slab is then sealer too early the following day, before the moisture has had the opportunity to leave again, blistering may occur. It is

recommended that an open slab be left until at least midday in good drying conditions to allow it to breathe out before applying the fi rst coat of sealer.

SEALER APPLICATION• Correct sealer should be chosen that delivers the required performance and breathability characteristics suitable to the substrate.• A trial patch is always recommended to ensure fi nal fi nish and performance characteristics are as required.• Sealer should only be applied as per recommended coverage rates. Not enough sealer and performance will be compromised. Too

much sealer and substrate breathability will be compromised and moisture / adhesion issues may be experienced.• Do not thin sealer with any solvent other than recommended compatible product. Different solvents have different fl ash points, which

can compromise sealer cure and performance characteristics. For example, sealer solvent fl ash point is 46 c, Xylene fl ash point is 26 c.• Do not park a motor vehicle on sealer surfaces, using appropriate sealer, for 7 days.• Remember – less is more! You can always add another coat; it’s much harder to remove if there is too much.

WHEN TO SEAL• Only when substrate is completely dry.• It is recommended that sealer is applied late morning to early afternoon – after substrate moisture has been released and dew point

has been exceeded.• Do not seal if surface / ambient temperature is too high, carrier solvent will evaporate too quickly and not allow resins / polymers to

coalesce at the correct rate.• Do not seal if rain is expected during initial cure time.• Do not seal if humidity is too high (>85%), or likely to be during the initial cure phase. Dew points also need to be considered.• Do not seal if surface / ambient temperature is too low (<10C) as carrier solvent will not evaporate and allow resins / polymers to

coalesce at the correct rate also do no seal if the surface / ambient temperature is too high (>35C). However direct sun, time of day, temperature increase / decrease etc. must still be a consideration.

• Weather details may be checked on the following website: http://www.bom.gov.au/climate/data/index.shtml?

MOISTURE RELATED ISSUES• Sealer coating bubbles / blisters – if excessive substrate moisture is present, this will try and leave the surface as increasing

atmospheric temperatures open substrate pores and draw moisture up. If sealer coating is yet to fully cure, and is still in a plastic state, moisture will be trapped under the coating and expand causing blisters. This situation is more common when using premium high solids sealers than lower solids equivalents.

• Sealer clouding – substrate moisture may become trapped within the sealer coating as it cures, exhibited by a white cloudy appearance.

• Sealer delamination – substrate moisture will retard sealer ability to penetrate and bond to the surface. The passage of moisture may then delaminate the sealer from the surface, resulting in a white appearance (caused by thousands of tiny cracks in the surface) of fl aking / peeling sealer.

Page 52: rhino range by thor building 2016

2

by RHINO INDUSTRIAL COATING SOLUTIONS

Problem Solution

Cloudy/milky surface appearance Ensure moisture issue has been rectifi ed.

For solvent based sealers - apply liberal coat of compatible solvent, leave to react and agitate effected areas. Solvent will re-emulsify / open up the sealer enough for the trapped moisture to be released. As solvent evaporates, sealer fi lm will cure as normal.

For water based sealers, removal and reapplication is required.

Bubbles/blisters For large blisters - ensure moisture issue has been rectifi ed.

For solvent based sealers - apply liberal coat of solvent, leave to react and re-emulsify sealer in effected areas. Rework sealer to dissolve blisters and allow to cure as normal.

Ensure blisters are not caused by the presence of existing incompatible sealers. If so, remove totally and re-apply.

Note: over-rolling during application may also trap small bubbles in the sealer coating.

For water based sealers, removal and reapplication is required.

Overlap lines Usually caused by application of insuffi cient fi lm thickness or poor surface preparation where dust etc may be concentrated in lines by application tools.

For solvent based sealers - if due to insuffi cient sealer, apply additional coat of sealer at correct fi lm thickness.

If due to contaminants, removal and reapplication is required.

For water based sealers, removal and reapplication is required.

Inconsistent sheen level Usually caused by inconsistent substrate porosity or standard of preparation.

Apply additional coat of sealer at correct fi lm thickness.

Delamination in between coats Usually caused by application of sealer over a non-compatible existing coating, or contamination between coats by dust, moisture etc.

Remove sealer totally and re-apply.

Delamination from substrate Usually caused by poor surface preparation, or when moisture is present in substrate during sealer application.

May also be caused if the substrate is in a poor condition / friable. A densifi er may be required before re-sealing.

Remove sealer totally and re-apply.

COMMON SEALER PROBLEMS AND SOLUTIONS

Page 53: rhino range by thor building 2016

3

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER ENHANCE PENETRATINGConcrete Sealer & TintTesting Approvals N/A

Description

Concrete Sealer - Enhance Penetrating is a complex blend of Silane/Siloxane technologies which results in a sealer thatpenetrates deep into masonry surfaces and impedes the passage of moisture providing long-term protection to substrates againstwater penetration. Concrete Sealer - Enhance Penetrating reacts with soluble salts in cementitious surfaces to block capillarieswhilst still allowing the substrate to release retained moisture (“breathe”).

Features & Benefi ts

• Invisible protection• Reduces ingress of water and minimises effl orescence

through its reaction with soluble salts and its water repellence.

• Excellent fungal and algal resistance• Long term U.V. resistance• Treated surfaces are easier to clean• Allows substrates to breathe

Areas of Use

• Clay brick• Concrete and concrete block• Reconstituted stone

• Fibre cement panels• Exposed aggregate panels• Natural stone

Technical Data

• Number of Coats:• Spreading Rate Per Coat:• Wet Film Per Coat:• Recoat (@25oC):

2-36-10m2/L100-166 microns1-2 hours

• Curing time: • Colour:• Thinner:• Shelf Life:

7 daysClearN/A12 months

• Number of Coats: 2-3• Spreading Rate Per Coat: 6-10m2/L• Wet Film Per Coat: 100-166 microns• Recoat (@25oC): 1-2 hours

• Curing time: 7 days• Colour: Clear• Thinner: N/A• Shelf Life: 12 months

Application Guide

Surface Preparation• Ensure all surfaces are clean, dry and free of contaminants.• Any white effl orescence salts must be removed by either dry brushing with a stiff bristle brush or treatment with Crommelin

Effl orescence Remover. Rinse thoroughly with clean water and allow to dry.• Ensure surface is dry by either testing with a moisture meter or by placing a square metre sheet of black plastic on an area most

likely to be damp. Place into position as sun gains heat and remove as sun loses heat. If condensation appears on plastic, do not apply product. Repeat until no condensation appears.

Application Procedure and Equipment• Application equipment should be by airless spray or for small areas a roller suitable for solvent borne products.• Whilst substrate must be saturated, do not allow the liquid product to sit on any surface. If it does not penetrate, spread surplus

with a brush until saturated into surface. • 1st coat – apply and allow to dry.• Apply 2nd coat when the fi rst is suffi ciently dry (to touch).

Page 54: rhino range by thor building 2016

4

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER ENHANCE PENETRATINGConcrete Sealer & TintTesting Approvals N/A

Precautions

• Must be applied to a dry substrate.• Do not allow to pool during application.

Cleaning

• Wash all equipment with Thor Concrete Sealer Thinners before product dries.

Health & Safety

Safety Precautions• Avoid breathing vapour. Wear organic vapour respirator meeting the requirements of AS1715 and AS1716.• Provide good ventilation – open windows and doors and use circulating fans.• Wear eye protection.• Wear PVC or neoprene gloves. Avoid contact with skin.• If product is splashed on skin it should be washed off with water before it can dry.• Keep out of the reach of children.

First Aid• Swallowed: If poisoning occurs contact a doctor or Poisons Information Centre. Do not induce vomiting. Risk of aspiration into

lungs. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.• Skin: Remove contaminated clothing and gently fl ush affected areas with soap and water. Seek medical attention if irritation

develops. Launder clothing before re-use.• Inhalation: Remove patient from exposure, into fresh air. Apply artifi cial respiration if patient has stopped breathing. Seek medical

attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

• Sizes:• Weights:• Dangerous Goods Class:• Hazchem Code:

15L, 200L.15kg, 200kg.33(Y)

• Flash Point:• UN Number:• Poisons Schedule:

31oC12635

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 55: rhino range by thor building 2016

5

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER GLOSS (21)

Concrete Sealer & TintTesting Approvals N/A

Description

Concrete Sealer - Gloss (21) is a tough gloss fi nish surface treatment that provides a classic “wet look” fi nish by restoring & enhancing natural colours. The product has been modifi ed to promote extremely low dirt pick up, making treated areas easier to maintain and keep clean. Worn or damaged areas can be recoated without stripping or grinding.

Features & Benefi ts

• Extends the life of concrete pavers by up to 40%.• Provides a clear, non-yellowing fi lm.• Resists oils, grease and general dirt pick up.

• Suppresses effl orescence.• Enhances the natural colour of the pavers, even in heavy use areas.

Areas of Use

• All previously uncoated areas of concrete requiring a stainresistant durable fi nish

• Domestic walkways and driveways• Warehouse fl oors• Bus stations

• Shopping malls• Pedestrian areas• Pattern concrete• Stencilled concrete

Technical Data

• Number of Coats• Spreading Rate Per Coat

1st Coat (thinned 10%) 2nd Coat

• Recoat (@25oC)

2 6m2/L7-8m2/LMin, 2 hours

• Curing time: • Colour: • Thinner:• Shelf Life:

7 daysClearThor Solvent CT12 months

Application Guide

Surface Preparation• On newly paved areas remove all loose material with a dry stiff bristle broom.• On weathered and worn paved areas remove all dirt, oil, grease and loose material using detergent and water, use degreasers

where necessary. Moss and algae should be treated and removed followed by high pressure water cleaning.

Application Procedure and Equipment• All surfaces must be thoroughly dry. Dampness in the pavers may spoil the clear fi nish, turning it milky. To test for moisture, tape

a clear plastic sheet (300mm x 300mm) over the pavers in the most likely damp area. If moisture appears on the underside of the plastic within 2 hours, the pavers are too damp. Repeat inspection every couple of days until no moisture is present.

• Sealing of sloping surfaces may increase the potential for pedestrians to slip. Slip Resistant Additive can be added to provide an improved slip resistant profi le. Please ensure to follow the ‘Application Procedure and Equipment’ method, stated in Slip Resistant Additive technical data sheet.

• For airless spray, apply direct from the container at a pressure of 800 -1000 p.s.i.

Page 56: rhino range by thor building 2016

6

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER GLOSS (21)

Concrete Sealer & TintTesting Approvals N/A

Precautions

• Do not apply if humidity is above 85% or if rain or dew is imminent.• Do not apply if temperature is over 35oC or under 5oC. WHere hot windy conditions occur, apply in the morning.• Concrete Sealer - Gloss (21) may increase the slipperiness depending on the surface and the quantity of sealer used.

Cleaning & Maintenance

• Any spills must be cleaned immediately. Spot cleaning should be carried out with diluted detergents or bleaches.• It is recommended that areas treated be scrubbed or mechanically cleaned monthly using appropriate cleaning fl uids.

Health & Safety

Safety Precautions• Avoid breathing vapour. Wear organic vapour respirator meeting the requirements of AS1715 and AS1716.• Provide good ventilation – open windows and doors and use circulating fans.• Wear eye protection.• Wear PVC or neoprene gloves. Avoid contact with skin.• If product is splashed on skin it should be washed off with water before it can dry.• Keep out of the reach of children.

First Aid• Swallowed: If poisoning occurs contact a doctor or Poisons Information Centre. Do not induce vomiting. Risk of aspiration into

lungs. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.• Skin: Remove contaminated clothing and gently fl ush affected areas with soap and water. Seek medical attention if irritation

develops. Launder clothing before re-use.• Inhalation: Remove patient from exposure, into fresh air. Apply artifi cial respiration if patient has stopped breathing. Seek medical

attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

• Sizes:• Weights:• Dangerous Goods Class:• Hazchem Code:

15L, 200L.15kg, 209kg.3.23(Y)

• Flash Point:• UN Number:• Poisons Schedule:

43oC12635

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 57: rhino range by thor building 2016

7

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER GLOSS (25)

Concrete Sealer & TintTesting Approvals N/A

Description

Concrete Sealer - Gloss (25) is a tough gloss fi nish surface treatment that provides a classic “wet look” fi nish by restoring &enhancing natural colours. The product has been modifi ed to promote extremely low dirt pick up, making treated areas easier tomaintain and keep clean. Worn or damaged areas can be recoated without stripping or grinding.

Features & Benefi ts

• Extends the life of concrete pavers by up to 40%.• Provides a clear, non-yellowing fi lm.• Resists oils, grease and general dirt pick up.

• Suppresses effl orescence.• Retains the natural colour of the pavers, even in heavy use areas.

Areas of Use

• All previously uncoated areas of concrete requiring a stainresistant durable fi nish

• Domestic walkways and driveways• Warehouse fl oors• Bus stations

• Shopping malls• Pedestrian areas• Pattern concrete• Stencilled concrete

Technical Data

• Number of Coats:• Spreading Rate Per Coat

1st Coat (thinned 10%) 2nd Coat

• Recoat (@25oC):

2

6m2/L7-8m2/LMin, 2 hours

• Curing time:• Colour: • Thinner: • Shelf Life:

7 daysClearThor Solvent CT12 months

Application Guide

Surface Preparation• On newly paved areas remove all loose material with a dry stiff bristle broom.• On weathered and worn paved areas remove all dirt, oil, grease and loose material using detergent and water, use degreasers

where necessary. Moss and algae should be treated and removed followed by high pressure water cleaning.

Application Procedure and Equipment• All surfaces must be thoroughly dry. Dampness in the pavers may spoil the clear fi nish, turning it milky. To test for moisture, tape

a clear plastic sheet (300mm x 300mm) over the pavers in the most likely damp area. If moisture appears on the underside of the plastic within 2 hours, the pavers are too damp. Repeat inspection every couple of days until no moisture is present.

• Sealing of sloping surfaces may increase the potential for pedestrians to slip. Slip Resistant Additive can be added to provide an improved slip resistant profi le. Please ensure to follow the ‘Application Procedure and Equipment’ method, stated in Slip Resistant Additive technical data sheet.

• For airless spray, apply direct from the container at a pressure of 800 -1000 p.s.i.

Page 58: rhino range by thor building 2016

8

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER GLOSS (25)

Concrete Sealer & TintTesting Approvals N/A

Precautions

• Do not apply if humidity is above 85% or if rain or dew is imminent.• Do not apply if temperature is over 35oC or under 5oC. WHere hot windy conditions occur, apply in the morning.• Concrete Sealer - Gloss (25) may increase the slipperiness depending on the surface and the quantity of sealer used.

Cleaning & Maintenance

• Any spills must be cleaned immediately. Spot cleaning should be carried out with diluted detergents or bleaches.• It is recommended that areas treated be scrubbed or mechanically cleaned monthly using appropriate cleaning fl uids.

Health & Safety

Safety Precautions• Avoid breathing vapour. Wear organic vapour respirator meeting the requirements of AS1715 and AS1716.• Provide good ventilation – open windows and doors and use circulating fans.• Wear eye protection.• Wear PVC or neoprene gloves. Avoid contact with skin.• If product is splashed on skin it should be washed off with water before it can dry.• Keep out of the reach of children.

First Aid• Swallowed: If poisoning occurs contact a doctor or Poisons Information Centre. Do not induce vomiting. Risk of aspiration into

lungs. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.• Skin: Remove contaminated clothing and gently fl ush affected areas with soap and water. Seek medical attention if irritation

develops. Launder clothing before re-use.• Inhalation: Remove patient from exposure, into fresh air. Apply artifi cial respiration if patient has stopped breathing. Seek medical

attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

• Sizes:• Weights:• Dangerous Goods Class:• Hazchem Code:

15L, 200L.15kg, 209kg.3.23(Y)

• Flash Point:• UN Number:• Poisons Schedule:

43oC12635

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 59: rhino range by thor building 2016

9

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER NEXT DAY WBSealingTesting Approvals N/A

Description

Concrete Sealer - Next Day WB is a waterborne sealer and curing compound for freshly poured concrete and in situ limestoneconcrete surfaces. It provides temporary immediate dust proofi ng and assists in stain protection whilst enabling the concrete to release moisture effectively. For longer term protection, Thor Concrete Sealer - Water Based should be applied to areas subject to reasonable traffi c once the beading of water no longer occurs. In any case consider reapplying Thor Concrete Sealer - Water Based after 2 years in service.

Features & Benefi ts

• Waterborne, no solvent fumes• Does not change surface appearance• Single coat application• Highly water repellent

• Dust proofs surface• Resists growth of algae and fungus• Assists curing when applied to fresh concrete• Surface binding properties

Areas of Use

• Newly installed in-situ concrete paving • Newly installed limestone-concrete paving

Technical Data

• Number of Coats:• Spreading Rate Per Coat: • Wet Film Per Coat: • Recoat (@25oC):

12-4m2/L250-500 microns30 mins

• Curing time:• Colour:• Thinner:• Shelf Life:

7 daysClearWater12 months

Application Guide

Surface Preparation• Surfaces should be clean and free of all contaminants. Any traces of grease or oil must be completely removed.• Use a high pressure spray nozzle to hose down and clean the surface. Allow to dry.

Application Procedure and Equipment• The preferred method of application is by low pressure or airless spray, using a “fl ood coat” technique.• Check application is thorough by wetting the treated area. Any dark areas (where substrate has been wet) must be re-coated once

the surface has dried.

Page 60: rhino range by thor building 2016

10

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER NEXT DAY WBSealingTesting Approvals N/A

Precautions

• Thor Concrete Sealer - Next Day WB will not prevent marking from motor vehicle tyres.• Thor Concrete Sealer - Next Day WB is alkaline and should therefore not be handled or applied with equipment made of or

containing aluminium or light alloys. For the same reason, care should be taken to avoid splashes on light alloy or aluminium or wooden components and glass (windows, etc) and any other alkali sensitive surfaces.

• Do not apply if temperature is below 10oC or relative humidity is above 85% or rain is imminent.

Cleaning

• Immediately after use fl ush equipment thoroughly with water and a little detergent.

Health & Safety

Safety Precautions• Provide good ventilation – open windows and doors and use circulating fans.• If product is splashed on skin it should be washed off with water before it can dry.• Wear gloves and eye protection during application.

First Aid• Swallowed: Contact a doctor or Poisons Information Centre. Do not induce vomiting. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

• Sizes:• Weights:• Dangerous Goods Class:

15L, 200L.15.5kg, 203kg.N/A

• Flash Point:• UN Number:

N/AN/A

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 61: rhino range by thor building 2016

11

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER NEXT DAY SBConcrete Sealer & TintTesting Approvals N/A

Description

Concrete Sealer - Next Day (SB) is a (SB) clear coating suited for use in both green and existing concrete. Concrete Sealer -Next Day (SB) will provide a low sheen to gloss fi nish and good colour enhancement of pigments and oxides leaving a ‘wet look’.

Concrete Sealer - Next Day (SB) is particularly suited to provide stain resistance and protection to freshly laid concrete 24 hoursafter the concrete is poured. When the concrete has fully cured, or 28 days after installation, apply Thor Gloss Sealer 21/25 or SatinSealer 23 for increased and longer term protection.

Features & Benefi ts

• Provides protection to concrete 24 hours after pouring.• Provides a clear, non-yellowing fi lm.• Resists oils, grease and general dirt pick up.

• Suppresses effl orescence.• Economical.

Areas of Use

• All previously uncoated areas of concrete requiring a stainresistant durable fi nish

• Domestic walkways and driveways• Warehouse fl oors

• Shopping malls• Pedestrian areas• Pattern concrete• Stencilled concrete

Technical Data

• Number of Coats:

• Spreading Rate Per Coat: • Recoat (@25oC):

Green concrete 1 coatCured concrete 2 -35-8m2/LMin. 2 hours

• Curing time: • Colour: • Thinner: • Shelf Life:

7 days(light foot traffi c 24 hours) ClearCrommelin Solvent12 months

Application Guide

Surface Preparation• Green Concrete• Freshly poured concrete should be left a minimum of 24 hours before sealing, or when the surface is adequately dry, shows no• indication of surface pooling and is cured enough to walk on.

• Existing Concrete• On weathered and worn concrete remove all dirt, oil, grease and loose material using detergent and water, and degreasers• where necessary. Moss and algae should be treated and removed followed by high pressure water washing.

Application Procedure and Equipment• Amount of colour enhancement and gloss level is dependant on surface porosity and amount of sealer applied.• Once a trial patch has been successfully applied full application can commence.• For airless spray, apply direct from the container at a pressure of 800 -1000 p.s.i.• Brush, Roller or lambswool applicators can also be used.

Page 62: rhino range by thor building 2016

12

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER NEXT DAY SBConcrete Sealer & TintTesting Approvals N/A

Precautions

• Do not apply if humidity is above 85% or if rain or dew is imminent.• Do not apply if temperate is over 35oC or under 5oC. Where hot windy conditions occur, apply in the morning.• Concrete Sealer - Next Day (SB) may increase the slipperiness depending on the surface and the quantity of sealer used.• Concrete Sealer - Next Day (SB) may not prevent tyre marking on some surfaces.

Cleaning & Maintenance

• Any spills must be cleaned immediately. Spot cleaning should be carried out with diluted detergents or bleaches.• It is recommended that areas treated be scrubbed or mechanically cleaned monthly using appropriate cleaning fl uids.

Health & Safety

Safety Precautions• Avoid breathing vapor. Wear organic vapor respirator meeting the requirements of AS1715 and AS1716.• Provide good ventilation – open windows and doors and use circulating fans.• Wear eye protection.• Wear PVC or neoprene gloves. Avoid contact with skin.• Keep out of the reach of children.

First Aid• Swallowed: If poisoning occurs contact a doctor or Poisons Information Centre. Do not induce vomiting. Risk of aspiration into

lungs. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.• Skin: Remove contaminated clothing and gently fl ush affected areas with soap and water. Seek medical attention if irritation

develops. Launder clothing before re-use.• Inhalation: Remove patient from exposure, into fresh air. Apply artifi cial respiration if patient has stopped breathing. Seek medical

attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions Pty Ltd. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

• Sizes:• Weights:• Dangerous Goods Class:• Hazchem Code:

15L15Kg3.23(Y)

• Flash Point:• UN Number:• Poisons Schedule:

43oC12635

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 63: rhino range by thor building 2016

13

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER SATIN TINT BASEConcrete Sealer & TintTesting Approvals N/A

Description

Concrete Sealer - Satin Tint Base is a tough satin fi nish surface treatment that provides protection, restores & enhances naturalcolours. The product has been modifi ed to promote extremely low dirt pick up, making treated areas easier to maintain and keepclean. Worn or damaged areas can be recoated without stripping or grinding and most stains are easily remo9ved by detergents.

Features & Benefi ts

• Extends the life of concrete pavers by up to 40%• Provides a clear, non-yellowing fi lm• Resists oils, grease and general dirt pick up

• Suppresses effl orescence• Retains the natural colour of pavers, even in heavy use areas.

Areas of Use

• All previously uncoated areas of concrete requiring a stain resistant durable fi nish

• Domestic walkways and driveways• Warehouse fl oors• Bus stations

• Shopping malls• Pedestrian areas• Pattern concrete• Stencilled concrete

Technical Data

• Number of Coats: • Spreading Rate Per Coat:

1st Coat (thinner 10%)2nd Coat

• Wet Film Per Coat:

2

6m2/L5m2/L167-200 microns

• Recoat (@25oC)• Curing time: • Colour: • Thinner: • Shelf Life:

Min. 2 hours7 daysClearCleaning & Thinning Solvent12 months

Application Guide

Surface Preparation• On newly paved areas removed all loose material with a dry, stiff bristle broom.• On weathered and warn paved areas remove all dirt, oil, grease and loose material using detergent and water, degreasers. Where

necessary, moss and algae should be treated and removed, followed by high pressure water cleaning.• All surfaces must be thoroughly dry. Dampness in the pavers may spoil the clear fi nish, turning it milky. To test for moisture tape

a clear plastic sheet (300mm x 300mm over the pavers in the most likely damp area. If moisture appears on the underside of the plastic within 2 hours, the pavers are too damp. Repeat inspection every couple of days until no moisture is present.

Application Procedure and Equipment• Sealing of sloping surfaces may increase the potential for pedestrians to slip. Thor Slip Resistant Additive can be added to

provide an improved slip resistant profi le. Please ensure to follow the ‘Application Procedure and Equipment’ method, stated in Thor Slip Resistant Additive technical data sheet.

• For airless spray, apply direct from the container at a pressure of 800-1000p.s.i. thin as necessary with Thor Concreter Sealer Thinners

Page 64: rhino range by thor building 2016

14

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER SATIN TINT BASEConcrete Sealer & TintTesting Approvals N/A

Precautions

• Do not apply if humidity is above 85% or if rain is imminent.• Do not apply if temperature is over 35 C or under 5 C. Where hoit windy conditions occur, apply in the morning.• Concrete Sealer – Satin Tint Base may increase the slipperiness depending on the surface and the quantities of sealer used

Cleaning & Maintenance

• Equipment can be cleaned with lacquer thinners or with Thor Concrete Sealer Thinners.• Any spills must be cleaned immediately. Spot cleaning should be carried out with diluted detergents or bleaches.• It is recommended that areas treated be scrubbed or mechanically cleaned monthly using appropriate cleaning fl uids

Health & Safety

Safety Precautions• Avoid breathing vapour. Wear organic vapour respirator meeting the requirements of AS1715 and AS1716.• Provide good ventilation – open windows and doors and use circulating fans.• Wear eye protection.• Wear PVC or neoprene gloves. Avoid contact with skin.• If product is splashed on skin it should be washed off with water before it can dry.• Keep out of the reach of children.

First Aid• Swallowed: If poisoning occurs contact a doctor or Poisons Information Centre. Do not induce vomiting. Risk of aspiration into

lungs. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.• Skin: Remove contaminated clothing and gently fl ush affected areas with soap and water. Seek medical attention if irritation

develops. Launder clothing before re-use.• Inhalation: Remove patient from exposure, into fresh air. Apply artifi cial respiration if patient has stopped breathing. Seek medical

attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions Pty Ltd. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

• Sizes:• Weights:• Dangerous Goods Class:• Hazchem Code:

15L, 200L15Kg, 207kg3.23(Y)

• Flash Point:• UN Number:• Poisons Schedule:

43oC12635

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 65: rhino range by thor building 2016

15

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER WATER BASEDSealingTesting Approvals Conforms with Paint Reference Number B15A in AS/NZS 2311:2000 Guide to the painting of buildings.

Description

Concrete Sealer - Water Based provides a clear, hard wearing water repellent coating that will enhance and protect theappearance of low and medium porosity masonry surfaces. The hard fi lm is resistive to water damage, disfi gurement by airbornepollutants and its water repellent properties are supplemented by a highly effective biocide to inhibit the growth of fungi, algae andlichens. Concrete Sealer - Water Based is both traffi cable and highly resistant to UV light. The use of Concrete Sealer - WaterBased under other waterborne fi nishes will improve their performance and durability. Concrete Sealer - Water Based can beapplied over cured decorative coatings.

Features & Benefi ts

• Clear satin to gloss fi nish• Hard wearing• Resists stains and damage to substrate• Resists algal and other growth

• UV stable• Safe and easy to use• Highly water repellent• Prevents ingress of ponded water

Areas of Use

• Concrete pavers• Stencilled concrete• Fibre cement sheet

• Clay pavers• Reconstituted and natural stone• Mineral bound magnesia board

Technical Data

• Number of Coats:• Spreading Rate Per Coat: • Wet Film Per Coat:• Recoat (@25oC):

2+10-12m2/L85-100 microns1 hour

• Curing time: • Colour: • Thinner: • Shelf Life:

7 daysClear (satin to gloss)Water12 months

• Properties - Volatile Organic Compound (VOC) Content • Test Method - ASTMD3960• Test Results - 23g/L

Application Guide

Surface Preparation• Clean surfaces of all contaminants such as effl orescence, mould, lichen, etc. Remove all grease, dust or dirt. Wash surface with

water and scrubbing brush, rinse and allow to dry thoroughly.

Application Procedure and Equipment• May be applied by brush, roller or spray depending on surface to be treated. For best protection results apply two coats.• Sealing of sloping surfaces may increase the potential for pedestrians to slip. Thor Slip Resistant Additive can be added to

provide an improved slip resistant profi le. Please ensure to follow the ‘Application Procedure and Equipment’ method, stated in Thor Slip Resistant Additive technical data sheet.

• For the 1st coat, mix 2 parts Concrete Sealer - Water Based to 1 part water (2:1).• Apply a thin but even wet coat (do not try to achieve too high a build).• Allow to dry for approximately 15 minutes.• When dry apply a 2nd coat of non-thinned Concrete Sealer - Water Based. Gloss (from satin to gloss) will vary with porosity and

amount of Concrete Sealer - Water Based applied. For a higher gloss fi nish, apply further coats.

Page 66: rhino range by thor building 2016

16

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER WATER BASEDSealingTesting Approvals Conforms with Paint Reference Number B15A in AS/NZS 2311:2000 Guide to the painting of buildings

Precautions

• Do not apply if air or surface temperature is below 10oC, if relative humidity is above 85% or if rain is imminent.• Must be applied to a dry substrate• Take care in wet, oily or other extreme conditions as the surface can become slippery.• Not recommended for use on glazed/glassy surfaces such as some ceramic tiles.

Cleaning & Maintenance

• Clean all equipment with water before product dries.• Any spills must be cleaned immediately. Spot cleaning should be carried out with diluted detergents or bleaches.• It is recommended that areas treated be scrubbed or mechanically cleaned monthly using appropriate cleaning fl uids.

Health & Safety

Safety Precautions• Provide good ventilation – open windows and doors and use circulating fans.• If product is splashed on skin it should be washed off with water before it can dry.• Wear gloves and eye protection during application.

First Aid• Swallowed: Contact a doctor or Poisons Information Centre. Do not induce vomiting. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions Pty Ltd. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

• Sizes:• Weights:• Dangerous Goods Class:

15L, 200L16Kg, 213kgN/A

• Flash Point:• UN Number:

N/AN/A

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 67: rhino range by thor building 2016

17

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

ENHANCE COLOURS Concrete Sealer & TintTesting Approvals N/A

Description

Enhance Colour is a 2L tinting system designed to complement Thor Concrete Sealer – Satin Tint Base by providing a colouralternative to rejuvenating aged concrete and masonry. When used in conjunction with Thor Concrete Sealer – Satin Tint Base,Enhance Colour is an ideal alternative to paving paints.

Features & Benefi ts

• 2L tint to 15L Thor Concrete Sealer - Enhance Penetrating

• Available in 6 colours• Resists oils, grease and general dirt pick up

• 1 coat system provides a wash of colour• 2 coat system is needed to achieve opacity• Colour penetrates up to 2mm

Areas of Use

• All previously uncoated areas of concrete requiring a stainresistant durable coloured fi nish

• Domestic walkways and driveways• Warehouse fl oors

• Shopping malls & Bus stations• Pedestrian areas• Pattern concrete• Stencilled concrete

Technical Data

• Number of Coats: • Spreading Rate Per Coat:

1st Coat (thinner 10%)2nd Coat

• Wet Film Per Coat:• Recoat (@25oC)

2 (for solid colour)

8m2/L8m2/L167-200 micronsMin. 4 hours

• Curing time: • Colour:

• Thinner: • Shelf Life:

7 daysBurnt Clay, Mid Gray, Charcoal, Light Grey, Warm Sand.Cleaning & Thinning Solvent12 months

Application Guide

Surface Preparation• Refer to Thor Concrete Sealer – Satin Tint Base Technical Data Sheets

Application Procedure and Equipment• 2L of Thor Concrete Sealer – Satin Tint Base needs to be removed from the 15L container.• The Enhance Colour needs to be added to the remaining 13L.• This should be stirred through for 10 minutes ensuring now air is entrapped.• Sealing of sloping surfaces may increase the potential for pedestrians to slip. Thor Slip Resistant Additive can be added to

provide an improved slip resistant profi le. Please ensure to follow the ‘Application Procedure and Equipment’ method, stated in Thor Slip Resistant Additive technical data sheet.

• For airless spray, apply direct from the container at a pressure of 800-1000p.s.i. thin as necessary with Thor Concreter Sealer Thinners

Precautions

• Do not apply if humidity is above 85% or if rain is imminent.• Do not apply if temperature is over 35 C or under 5 C. Where hoit windy conditions occur, apply in the morning.• Concrete Sealer – Satin Tint Base may increase the slipperiness depending on the surface and the quantities of sealer used

Page 68: rhino range by thor building 2016

18

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

ANTI-GRAFFITI SEAL N12Anti-Graffi ti CoatingsTesting Approvals N/A

Description

Anti-Graffi ti Seal N12 is a waterborne non-sacrifi cial anti-graffi ti coating incorporating a specialized polymer system that provides aclear barrier against graffi ti and other pollutants on dense substrates. Graffi ti can be removed by the use of Thor Concrete SurfaceCleaner. Anti-Graffi ti Seal N12 is UV and weather resistant and contains a highly effective dry fi lm fungicide to inhibit biologicalgrowth.

Features & Benefi ts

• Does not alter the surface appearance of suitable substrates.• Resistant to a wide range of graffi ti• Non toxic, environmentally friendly system – low VOC• Provides antimicrobial protection for the treated surface

• Excellent UV stability and weather resistance• Long term biocidal protection• Ease of application• Excellent water repellency

Areas of Use

• Marble• Granite• Terrazzo

• Reconstituted stone• Polished and prefab concrete• Vitrifi ed Stones

Technical Data

• Number of Coats: • Spreading Rate Per Coat: • Wet Film Per Coat:• Recoat (@25oC)

2Up to 30m2/L20-30 microns20 minutes

• Curing time: • Colour: • Thinner: • Shelf Life:

24 hoursMilky liquidWater12 months

• Properties - Volatile Organic Compound (VOC) Content • Test Method - ASTMD3960• Test Results - 21.11g/L

Application Guide

Surface Preparation• Ensure area to be treated is clean and dry.

Application Procedure and Equipment• The amount of coats and coating method will depend on the type of surface being treated. Refer to Specifi cations.• Stir well before use.• Anti-Graffi ti Seal N12 is usually applied to substrates using a wiping method. This can be carried out with either a lint free cloth

or lambs wool applicator.• Surface should be left with a consistent but light fi lm and allowed to dry for 48 hours.• Once dry, any remaining visible fi lm build should be washed with warm soapy water, rinsed and buffed with soft cloth.• NOTE – Application of a test area is required to test suitability of fi nish.

Graffi ti Removal• Graffi ti should be removed as soon as possible using Thor Cleaner HD.• After removal of graffi ti, substrate should be washed with clean water.• NOTE – After removal check substrate for damage. After several removals it may be necessary to recoat.

Page 69: rhino range by thor building 2016

19

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

ANTI-GRAFFITI SEAL N12Anti-Graffi ti CoatingsTesting Approvals N/A

Precautions

• Do not apply if the temperature is below 10oC or relative humidity is above 85%, or if rain is imminent.

Cleaning

• Clean all equipment with hot water and detergent before product dries.

Health & Safety

Safety Precautions• Provide good ventilation – open windows and doors and use circulating fans.• If product is splashed on skin it should be washed off with water before it can dry.• Wear gloves and eye protection during application.

First Aid• Swallowed: Contact a doctor or Poisons Information Centre. Do not induce vomiting. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions Pty Ltd. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

• Sizes:• Weights:• Dangerous Goods Class:

15L15.5KgN/A

• Flash Point:• UN Number:

N/AN/A

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 70: rhino range by thor building 2016

20

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SEALER THINNERS Thinners & ReducersTesting Approvals N/A

Description

Concrete Sealer Thinners is an aromatic hydrocarbon used as a general purpose solvent/diluent for solvent based acrylic resinsolutions and as a clean up solvent for these and other solvent based systems.

Areas of Use

• Used as a diluent for solvent based acrylic resin systems. • May be used as a clean up solvent for all Thor solvent based products.

Typical Properties

• Boiling Point:• Flash Point: • Appearance/Odour:

155-180oC44oC approx (closed cup)Colourless, strong odour

• Specifi c Gravity:• Vapour Pressure:• Solubility in Water:

0.87 @ 25oC1.7kPa @ 38oCBelow 0.1% mass

Precautions

• Concrete Sealer Thinners is a fl ammable aromatic solvent. Store in a cool place.• Do not use in poorly ventilated, Keep container sealed when not in use.

Health & Safety

Safety Precautions• Provide good ventilation – open windows and doors and use circulating fans.• If product is splashed on skin it should be washed off with water before it can dry.• Avoid contact with skin and eyes.• Wear gloves and eye protection during application.

First Aid• Swallowed: Contact a doctor or Poisons Information Centre. Do not induce vomiting. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions Pty Ltd. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

Sizes:Weights:Dangerous Goods Class:

15L15kg3

Flash Point:UN Number:

43oC1268

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 71: rhino range by thor building 2016

21

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

THOR SUPER GLOSS Two Part CoatingsTesting Approvals N/A

Description

Thor Super Gloss is a two component, high solids, high gloss, clear coating that combines the excellent adhesion and toughness of Polyaspartic resin technology with the advantages of a one coat system.

Features & Benefi ts

• High gloss fi nish• Tough impervious, high abrasion resistant coating• Excellent adhesion to substrate• High chemical resistance, including oils, fats and

solvents• Resists hot tyre pick up

• Fast cure• Suitable for use over Thor Concrete Sealer – Satin (23), Thor

Waterborne Epoxy Sealer and Crommelin Flake Floor systems• Easy 1:1 by weight or volume mix ratio• Exceptional UV resistance

Areas of Use

Concrete fl oors in:• Workshops and showrooms• Garages and sheds

• Domestic dwellings• Restaurants• Hospitals and laboratories

Technical Data

Thor Super Gloss may be used as a straight 1:1 by weight or volume mix, or may be thinned with Thor Concrete Sealer Thinners to improve surface penetration, extend pot life, increase coverage rates and aid application.

Note: Any addition of solvent must only take place after part A and part B have been thoroughly mixed. Do not add thinnerin access of recommended volumes

Mix Ratio 1:1Number of Coats:Wet Film Per Coat:Dry Film Per Coat:Volume Solids:Pot Life (@25oC)Set to touch (@25oC)Touch dry (@25oC)Dry to handle (@25oC)

Total Volume 7.2L1220 microns max270 mixrons max80.6%1 hour 20 minutes5 hours 40 minutes8 hours 30 minutes11 hours

Coverage:Curing time:

Colour:Thinner:Shelf Life:

3.3m2/L1 day light traffi c3 days vehicular7 days full chemical cureClearN/A6 months

Mix Ratio 1:1 + 200mlThinnerNumber of Coats:Wet Film Per Coat:Dry Film Per Coat:Volume Solids:Pot Life (@25oC)Set to touch (@25oC)Touch dry (@25oC)Dry to handle (@25oC)

Total Volume 7.2L

1160 microns max220 mixrons max78.1%1 hour 20 minutes5 hours 40 minutes8 hours 30 minutes11 hours

Coverage:Curing time:

Colour:Thinner:Shelf Life:

4.1m2/L1 day light traffi c3 days vehicular7 days full chemical cureClearN/A6 months

Page 72: rhino range by thor building 2016

22

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

THOR SUPER GLOSS Two Part CoatingsTesting Approvals N/A

Mix Ratio 1:1 + 400ml ThinnerNumber of Coats:Wet Film Per Coat:Dry Film Per Coat:Volume Solids:Pot Life (@25oC)Set to touch (@25oC)Touch dry (@25oC)Dry to handle (@25oC)

Total Volume 7.6L

1120 microns max150 mixrons max75.8%2 hours5 hours 40 minutes8 hours 30 minutes10 hours 30 minutes

Coverage:Curing time:

Colour:Thinner:Shelf Life:

5.6m2/L20 hours light traffi c3 days vehicular7 days full chemical cureClearN/A6 months

Properties Test Method Test Results

Salt ResistanceHot Water ResistanceAbrasion ResistanceSolvent ResistanceSKYDROL ResistanceAcid ResistanceAlkali ResistanceVOC Content (without additional solvent) AOASD181

ExcellentExcellentExcellentFairGoodGood (low concentrates)Good170g/L

Application Guide

GENERAL INFORMATIONMoisture Vapor Emissions PrecautionsAll interior concrete fl oors not poured over an effective moisture vapor retarder are subject to possible moisture vapor transmission that may lead to blistering and failure of the coating system. It is the coating applicator’s responsibility to conduct relative humidity probe testing to determine if excessive levels of vapor emissions are present before applying any coatings. Rhino Industrial Coating Solutions will not be held responsible for coating failures due to undetected moisture vapor emissions.

Surface PreparationConcrete must be cured 30 days and be clean, structurally sound, and free of wax, loose paint or curing compounds. Concrete should be diamond ground to achieve a minimum 125 micron profi le. If more than one coat is required, due to surface profi le or porosity , and more than 12 hours has elapsed between coats on the coating cannot be indented with a fi ngernail, abrade coat 1 with 80-100 grit sandpaper or screen to ensure intercoat adhesion.

Mixing InstructionsAdd the entire contents of Part B to the Part A bucket. (The mixing ratio is 1 part a to 1 part B by weight or volume)

Mix for 1 full minute using slow speed drill, scraping the bottom and sides of the mixing container. Mix only the amount witch can be applied within 20 minutes.

If additional Thor Concrete Sealer Thinners is used, this is to be added after part A and part B has been mixed together. Do not add more thinners, or other solvents than recommended.

Application Recommendations Thor Super Gloss may be applied by lint free micro-fi ber roller or lamb’s wool applicator. It is vital that all applicators are lint and dust free, preventing contamination of the coating and adversely affecting the fi nal fi nish. Due to short pot life, it is advised to change applicators every hour.

On large jobs, the applicator should wear spiked shores to walk on the wet material Application should take place immediately after mixing. A wet edge must be maintained during application Application rate must be greater than 1.8m2/L (4500 micron), and puddling of material must be avoided. Thick fi lms may entrap solvent or cause CO² bubbles that will appear as frosted areas.

Protect from water, moisture vapor and air borne contaminants including dust during the curing process.

Page 73: rhino range by thor building 2016

23

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

THOR SUPER GLOSS Two Part CoatingsTesting Approvals N/A

Precautions

• Use only with adequate ventilation/ or a cartridge type respirator designed to be used for organic vapour. Avoid contact with the skin, wear protective gloves and glasses. Read Material Safety Data Sheet before using.

• Various State OH&S regulations and the Building Code of Australia include requirements for safe design in buildings. One aspect of this is slip resistance and Rhino Industrial Coating Solutions recommend having slip resistance measurements performed on a trial area of the fl oor being coated if slip resistance is a factor in specifi cation.

• Do not apply to surfaces that are below 10°C or when relative humidity is above 85%.• Poor Mixing or inaccurate mixing ratios will result in variable cure and less than optimum hardness.

Cleaning

• Clean equipment with Thor Concrete Sealer Thinners after use and before cure.

Health & Safety

Safety Precautions• Provide good ventilation – open windows and doors and use circulating fans.• If product is splashed on skin it should be washed off with water before it can dry.• Wear gloves and eye protection during application.

First Aid• Swallowed: Contact a doctor or Poisons Information Centre. Do not induce vomiting. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions Pty Ltd. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

Sizes:Weights:Dangerous Goods Class:

7.2L kit7.2Kg3 (Part B)

Flash Point:UN NUmber:

38°C (Part B)1263 (Part B)

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 74: rhino range by thor building 2016

24

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

WATERBORNE EPOXY SEALER Two Part CoatingsTesting Approvals N/A

Description

Waterborne Epoxy Sealer is a two component waterborne epoxy sealer that combines the excellent adhesion and toughness ofepoxy resins with the advantages of using water as a carrier. VOC Content of Waterborne Epoxy Sealer is below the maximumVOC Content for Architectural and Interior Sealants as required by Green Star Offi ce Design V2, V3, and Offi ce Interiors V1.1.

Features & Benefi ts

• Tough impervious coating with low/semi-gloss fi nish• Excellent adhesion to damp or dry surfaces• High chemical resistance, including oils, fats and

solvents• Simple to use with 1:1 mixing ratio

• Non-toxic and non-fl ammable• Easily cleaned up with water• Easy to apply by brush, roller or spray• Chemical resistant

Areas of Use

Controlling rising damp prior to application of:• Waterproofi ng membranes• Other coatings

Coating of concrete fl oors in:• Workshops• Food Processing• Hospitals & Laboratories

Technical Data

Number of Coats:Spreading Rate Per Coat:Wet Film Per Coat:Recoat (@25oC)Pot Life (@25oC)Pot Life (@30oC)

25-7m2/L150-200 micronsWhen traffi cable (4-6 hrs)45 minutes25 minutes

Curing time:Colour:Thinner:

Shelf Life:

2-3 daysLight Grey5% Water (if required, added to the MIXED product)6 months

Properties Test Method Test Results

Salt ResistanceHot Water ResistanceAbrasion ResistanceSolvent ResistanceSKYDROL ResistanceAcid ResistanceAlkali ResistanceVOC ContentVolume Solids Content

APASD181

ExcellentExcellentExcellentFairGoodGood (low concentrates)Good59g/L57.5%V/V

Page 75: rhino range by thor building 2016

25

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

WATERBORNE EPOXY SEALER Two Part CoatingsTesting Approvals N/A

Application Guide

Surface Preparation• Concrete surfaces should be free from grease and oil – if necessary, clean with industrial grade degreaser or apply a poultice.• Steps must be taken to remove laitance. This is best carried out by using either mechanical abrasion or acid etching. Upon

completion of etching, neutralize, rinse thoroughly and allow to dry.

Application Recommendations• Mix Parts 1 and 2 separably fi rst.• Do not mix more product than will be used in 40 minutes as curing will occur but not appear obvious.

NOTE: Recommended at 25 C and 50% relative humidity. An increase in temperature will reduce the amount of product to be mixed. A decrease in temperature will increase the amount of product that can be mixed.

• Mix equal parts by volume of Part 1 and Part 2 together thoroughly. It is strongly suggested to use a mixing drill and mixing blade. Mix for at least 3-7 minutes

• Apply to roller, brush or airless spray.• When changing from on mix to a new mix, clean out the mixing bucket and roller tray. Old mixture will contaminate the new mix.

Roller covers must be cleaned or replaced. It is important that the old mixture does not contaminate the new mix.• To provide a light profi le slip resistant fi nish add Thor Slip Resistant Additive to mixed Waterborne Epoxy Sealer at a rate to

achieve the desired fi nish.• To achieve the desired slip resistant profi le, broadcast the appropriate dry graded aggregate into the wet 1st coat and allow to

dry. Remove excess aggregate and over coat with 2nd coat.

Precautions

• Do not apply to surfaces that are temperature below 10oC or when relative humidity is above 85%.• Poor mixing or inaccurate mixing ratios will result in a variable cure and less than optimum hardness• Do not apply solvent base adhesives or sealants before Waterborne Epoxy Sealer is hard dry.

Cleaning & Maintenance

• Clean equipment with Thor Concrete Sealer Thinners.

Health & Safety

Safety Precautions• Provide good ventilation – open windows and doors and use circulating fans.• If product is splashed on skin it should be washed off with water before it can dry.• Wear gloves and eye protection during application.

First Aid• Swallowed: Contact a doctor or Poisons Information Centre. Do not induce vomiting. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions Pty Ltd. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Page 76: rhino range by thor building 2016

26

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

WATERBORNE EPOXY SEALER Two Part CoatingsTesting Approvals N/A

Transport & Storage

Sizes:Weights:Dangerous Goods Class:

8L, 20L kit10Kg, 25KgN/A

Flash Point:UN Number:

N/AN/A

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 77: rhino range by thor building 2016

27

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE STAIN REPEL Other Surface TreatmentsTesting Approvals N/A

Description

Concrete Stain Repel is a unique waterborne surface treatment with great resistance to chemicals and staining agents. It hasoutstanding water repellency and binding properties. It is both a penetrating and a fi lm forming sealer - this provides protectionwhilst allowing the various substrates to “breathe” normally. It also contains an antimicrobial additive inhibiting mould and algalgrowth.

Features & Benefi ts

• Allows the substrate to breathe• Highly water repellent• Retains substrates natural appearance• Superior stain and chemical resistance

• Provides antimicrobial protection for the treated surface• UV stable• Chemically bonds to mineral substrates• Environmentally friendly – low V.O.C.

Areas of Use

• Marble, granite and porcelain substrates (kitchen and bathroom areas)

• Reconstituted stones• Polished concrete

• Natural quarry stones• Capping• Paved or traffi cable areas

Technical Data

Number of Coats:Spreading Rate Per Coat:Wet Film Per Coat:Recoat (@25oC)

2Up to 30m2/L15-30 microns0.5-2 hours

Curing time:Colour:Thinner:Shelf Life:

7 daysClearWater12 months

Properties Test Method Test Results

Water Absorption by Mass Gain

Volatile Organic Compound (VOC) Content

1hr immersion in water ofcoated porcelain tile

23g/L

< 1% mass gain

SCAQMD 304-91

Page 78: rhino range by thor building 2016

28

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE STAIN REPEL Other Surface TreatmentsTesting Approvals N/A

Application Guide

Surface Preparation• Surfaces should be clean and dry for maximum penetration.

Application Procedure & Equipment• Stir well before use• May be applied using a brush, spray or lambs wool applicator.• Surface should be left with a consistent but light fi lm and allowed to dry for 48 hours.• Once dry, any remaining visible streaky fi lm build up on highly dense surfaces such as polished marble, should be washed with

warm soapy water, rinsed and buffed with soft cloth.

Precautions

• Do not apply if temperature is below 10oC or relative humidity is above 85% or rain is imminent.• Protect other surfaces and materials from overspray or splashes. Mask windows and doors. Any spillage or marks should be

removed with water immediately.

Cleaning

• Concrete Stain Repel may become sticky while curing - clean up equipment in water immediately after use.

Health & Safety

Safety Precautions• Provide good ventilation – open windows and doors and use circulating fans.• If product is splashed on skin it should be washed off with water before it can dry.• Wear gloves and eye protection during application.

First Aid• Swallowed: Contact a doctor or Poisons Information Centre. Do not induce vomiting. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions Pty Ltd. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Page 79: rhino range by thor building 2016

29

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE STAIN REPEL Other Surface TreatmentsTesting Approvals N/A

Transport & Storage

Sizes:Weights:Dangerous Goods Class:

4L, 15L4kg, 15kgN/A

Flash Point:UN Number:

N/AN/A

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 80: rhino range by thor building 2016

30

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SURFACE CLEANER Other Surface TreatmentsTesting Approvals N/A

Description

Concrete Surface Cleaner is a general purpose degreaser and cleaner designed to remove grease, grime and dirt etc, from avariety of surfaces such as metal, wood and concrete.

Features & Benefi ts

• Fast-acting • Rinsable with water

Areas of Use

• Degrease metal prior to priming• Degrease concrete surfaces prior to sealing

• Degreasing of car engines• Paint brush restorer

Technical Data

Number of Coats:Spreading Rate Per Coat:Wet Film Per Coat:Recoat (@25oC)

N/A10-12m2/LN/AN/A

Curing time:Colour:Thinner:Shelf Life:

N/AClearN/A12 months

Application Guide

Application Procedure & Equipment• Mechanically remove any large deposits of grease and dirt. Apply by brush or cloth a liberal quantity of Concrete Surface Cleaner

to the area to be treated.• It is recommended to work in manageable areas of approximately 10-20m2 at a time, particularly when working outdoors.• Scrub the area to loosen the contaminants.• After approximately 10 minutes, use fresh water, under pressure, to remove the degreaser.• Inspect the cleaned treated area, and repeat the procedure to any areas where contamination remains.• Allow the substrate to dry thoroughly prior to sealing or painting.

Precautions

• Concrete Surface Cleaner will soften painted surfaces and some plastics. It is recommended to test the product on the substrate prior to doing the whole project.

Cleaning

• All equipment can be rinsed clean with water.

Page 81: rhino range by thor building 2016

31

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

CONCRETE SURFACE CLEANER Other Surface TreatmentsTesting Approvals N/A

Health & Safety

Safety Precautions• Avoid breathing vapour. Wear organic vapour respirator meeting the requirements of AS1715 and AS1716.• Provide good ventilation – open windows and doors and use circulating fans.• Wear eye protection.• Wear PVC or neoprene gloves. Avoid contact with skin.• If product is splashed on skin it should be washed off with water before it can dry.• Keep out of the reach of children.

First Aid• Swallowed: Contact a doctor or Poisons Information Centre. Do not induce vomiting. Give water to drink.• Eye: Gently fl ush with running water, holding eyelids open for 15 minutes. Seek medical attention.• Skin: Remove contaminated clothing and gently fl ush affected areas with soap and water. Seek medical attention if irritation

develops. Launder clothing before re-use.• Inhalation: Remove patient from exposure, into fresh air. Apply artifi cial respiration if patient has stopped breathing. Seek

medical attention.

For detailed information refer to product label and the current Material Safety Data Sheet available from Rhino Industrial CoatingSolutions Pty Ltd. In the case of an emergency please call the Poisons Information Centre on 13 11 26

Transport & Storage

Sizes:Weights:Dangerous Goods Class:Hazchem Code:

15L15Kg33(Y)

Flash Point:UN Number:Poisons Schedule:

43oCN/A6

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 82: rhino range by thor building 2016

32

by RHINO INDUSTRIAL COATING SOLUTIONS

TECHNICAL DATA SHEET

SLIP RESISTANT ADDITIVE Other Surface TreatmentsTesting Approvals N/A

Description

Slip Resistant Additive is a revolutionary ceramic sphere for all fi lm forming coatings where a slip resistive profi le is required. Bysimply adding this white powder you will improve the slip resistant profi le of the fi nished coating.

Features & Benefi ts

• Adds a slip resistant profi le to Thor Sealers and Coatings.• Colour & size less visible in clear coatings than silica

aggregates

• Increases compressive strength• Will not settle when added to sealer• Improves impact resistance

Areas of Use

• Driveways• Pathways• Steps

• Ramps• Wet Areas• Floors

Technical Data

• Width:• Weight:

130 microns (average)0.4kg/1L

• Consumption 375mL / 15LThis can be varied dependingon desired profi le.

Application Guide

Application Procedure & Equipment• Add the Slip Resistant Additive at the amount required to achieve the desired profi le.• It is essential to ensure the Slip Resistant Additive is poured slowly into the sealer whilst stirring.• Maintain stirring during application to ensure an even distribution of the Slip Resistant Additive and an even fi nish.• Application of sealer with Slip Resistant Additive should follow as the procedures for the particular Thor Industrial Sealing and

Flooring Coatings.

Precautions

• A test patch should always be carried out.• Do not apply too heavily, as sealer performance will be affected.

Transport & Storage

• Sizes:• Weights:• Dangerous Goods Class:

250ml and 10L450gN/A

• Flash Point:• UN Number:

N/AN/A

Disclaimer

Thor Building Products PTY LTD ® and other marks followed by ® are registered trademarks. Marks followed by the symbol of TM aretrademarks. Any advice, recommendation, information, assistance or service provided by Thor Building Products PTY LTD ® inrelation to its products or their use is given in good faith, however is provided without responsibility or liability. Customers need toundertake their own assessment to determine the suitability of a product for the particular use intended. As the performance of anyproduct is subject to a wide variety of different surface types as well as environmental and surface-specifi c conditions, it is essentialthat a sample of the product be applied to the intended area of use to ensure it is acceptable in appearance and fi nish and that itperforms on the specifi c surface acceptable in appearance and fi nish and that it performs on the specifi c surface.

Page 83: rhino range by thor building 2016