ris-reportingimagemed.pk/assets/pdfs/healthcare/iq-ris 3.1...cally handed over to the iq-webx web...
TRANSCRIPT
perfect reports
RIS-REPORTINGMaNaGEMENT Of REPORTS, dIcTaTIONS aNd TRaNScRIPTIONS IN iQ-RIS
VERS
ION
3.1
2
Using iQ-RIS dictation modules, ra-diologists can dictate their reports digitally, transmit dictations to local or remote transcriptionists, use voice recognition systems or the innovative structured report assistant.
iQ-RIS supports several report formats, such as DICOM Structured Reports, PDF or the classic MS Office Word® format. Reports can easily be printed, stored on optical media or automati-cally handed over to the iQ-WEBX web portal (PACS) for the computer-ized distribution to connected hospi-tals or referring physicians.
Since the way in which radiologists perform dictations tends to vary,
dictation & reporting tools for the most demanding radiologists With the new release of iQ-RIS REPORTING 3.1, radiology reporting has never been easier!
the iQ-RIS REPORTING modules have been structured to offer very flexible and efficient options.:
iQ-RIS REPORTING PHYSICIAN pro-vides a user interface optimized to type-in, edit and manage medical findings in a structured way. It offers advanced functions to format the text, create and use context-specific report templates and to distribute the report at any time.
Users may dictate reports digitally and transmit these dictation files to local or remote typists with the iQ-DICTATION module.
Using iQ-RIS REPORTING TRANSCRIP-TIONIST, transcriptionists type in dic-tation files they receive from radi-ologists. Afterwards, the transcribed reports are ready to be validated by the radiologist who dictated them.
With the integration of the speech recognition engine iQ-VOICE, iQ-RIS is able to understand the human voice either online or both, online and offline. Dictations in iQ-VOICE are automatically converted into writing and can be edited and vali-dated right after being finished, thus saving time and increasing the ope-rational efficiency.
iQ-RIS REPORTING
the solUtion can Be so simple.
3
a cB
iQ-RIS REPORTING SCREENSHOTS
iQ-RIS REPORTING
dictation modUles & fUnctionalitiesONlINE VOIcE REcOGNITION
lIcENSINGOfflINE VOIcE REcOGNITION
dIcTaTION wIThOuT VOIcE REcOGNITION
iQ-dIcTaTION No 1 license per PC No Yes
iQ-VOIcE dIcTaTION
No 1 user profile to be used on any PC within a network
No Yes
iQ-VOIcE lOcal Yes 1 voice profile limited to a single PC No No
iQ-VOIcE NET Yes 1 roam. voice profile to be used on any PC within a network
No No
iQ-VOIcEPRO wORKflOw
Yes 1 roam. voice profile to be used on any PC within a network
Yes Yes
a Reports can be exported to the fol-lowing formats: XML, DICOM SR, DICOM Encapsulated PDF*, PDF*, Word* and HL7 (optional). It is pos-sible to adapt the Word template to the customer’s layout and include almost any information stored in iQ-RIS.
*MS Word license required
B The unique Structured Report ed-itor supports automatic, context-specific report templates.
c The Report Module allows users to write one or more reports for a study, to manage the report sta-tus compliant with IHE guidelines (partial/complete, unverified/veri-fied) or to use customized tem-plates.
4
modUles & their fUnctionalities
fEaTuREiQ-RIS
REPORTING PhYSIcIaN
iQ-RIS REPORTING
TRaNScRIPTIONIST
iQ-dIcTaTION
iQ-VOIcEdIcTaTION
iQ-VOIcE lOcal
iQ-VOIcE NET
iQ-VOIcE PRO wORKflOw
iQ-VOIcE SERVER
dictating/sending files to a transcripti-onist;voice recognition-ready
*
Online voice recog-nition on a single PCOnline voice reco-gnition on any PC within the networkOnline/offline voice recognition on any Pc within the net-workOnline/offline voice recognition and correction/ transcription by another person
*
iQ-RIS REPORTING & iQ-vOICE
+ Multiple worksta-tions/ network
+ Workflow/ delegated correc-
tion
iQ-DICTATION oriQ-VOICE DICTATIONno
no
no
yes
yes
yes
yes
iQ-VOICE LOCAL
iQ-VOICE NET
iQ-VOICE PRO WORKFLOW
The depicted decision tree is a quick, step-by-step diagnosis to find the so-lution that meets each radiologist’s individual needs.
Automatic voice recognition
*Two licenses required
5
iQ-RIS REPORTING FEATURES
iQ-RIS REPORTING PhYSIcIaN Structured reporting using specific, context-sensitive report templates regarding proce-
dures, modalities, physicians and body parts Complementary reports Locking study records while reporting to avoid double reading (NEW!) DICOM compliant status management (complete, verified) Creation of Office Word® or PDF documents, DICOM SR or DICOM encapsulated PDF
Customizable automatic actions that are implemented after report verification (NEW!) Automatic color prioritization of required previous reports (NEW!) Automatic report storage in iQ-RIS and the respective DICOM archive after validation Optional integration of external dictation management systems (e.g. PowerScribe® 4, 5, 360; complete list upon request) Foot switch support (e.g. AltoEdge USB Foot Pedal, VEC Infinity, vPedal, Olympus, Philips) iQ-RIS REPORTING
TRaNScRIPTIONIST Structured reporting using specific, context-sensitive report templates regarding proce- dures, modalities, physicians and body parts DICOM compliant status management (complete, verified) Creation of Office Word® or PDF documents, DICOM SR or DICOM encapsulated PDF Manual storage of reports in iQ-RIS and respective DICOM archive
iQ-dIcTaTION Digital dictations in three different modes: patient, study, other Management of dictation priorities (low, normal, high) by using a color system Suggested for digital dictations with a high number of users on a low number of PC clients
iQ-VOIcE dIcTaTION Digital dictations in three different modes: patient, study, other Management of dictation priorities (low, normal, high) by using a color system Option to easily implement voice recognition later on One iQ-VOICE server required per site Suggested for a low number of users on a high number of PC clients
6
iQ-RIS REPORTING FEATURES
iQ-VOIcE lOcal Speech recognition directly in iQ-RIS (text is shown immediately on screen) Immediate review of the dictated text Customizable voice commands to control behavior of iQ-RIS REPORTING module Supported data formats: WAV, ACM, DSS and DS2 For a single PC and a single user, only
iQ-VOIcE NET (NEw!) In addition to iQ-VOICE LOCAL: Online speech recognition on any PC within a network One iQ-VOICE SERVER required per site
iQ-VOIcE PRO wORKflOw (NEw!) In addition to iQ-VOICE NET: Offline voice recognition (delayed voice recognition using the voice recognition engine; subsequent correction by typist and/or user)
Option to pass audio recordings and the automatically transcribed text for correction One iQ-VOICE server required per site EXPORT DICOM Structured Reports (default) XML Microsoft® Word >= 2003 using individual letter templates (MS Word license required) Portable data format (PDF) using individual letter templates (MS Word license required) HL7 ORU messages using the optional HL7 ORU module VOIcE REcOGNITION laNGuaGES Dutch, English, German, French, Italian, Spanish
7
iQ-RIS COmPATIblE dEvICES
The iQ-DICTATION and iQ-VOICE modules do NOT include any dictation hardware. Please refer to the table below to find out which devices are recommended. Other compatible devices are available upon request.
iQ-dIcTaTION iQ-VOIcE SERIES
Dictation devices Olympus DirectrecDR-1000
Olympus DS series
Philips SpeechMikeAir 3000
Philips DPM series
Philips SpeechMikeClassic 5262
Grundig Digta series
vDictate Mk I / MkII
Foot switches AltoEdge USB FootPedal
Grundig
VEC Infinity IN-USB-1 / IN-USB-2 Olympus
VEC Infinity IN-DB9 VEC Infinity
vPedal vP-1 (USB) Philips
vPedal vP-1 (Serial)
8
© 2
012
IMA
GE
Info
rma
tion
Syst
ems L
td. –
Fo
r a B
ette
r Vie
w in
Dia
gno
stic
s! iQ
-RIS
3.1
Rep
ort
ing
INT
EN 0
04R
iQ-SYSTEM PacS The full featured, reliable and affordable PACSiQ-Nuc Complete package for nuclear image processingiQ-RIS The smooth radiology information systemIMaGE dISPlaYS Medical diagnostic displays
oUr prodUcts for YoUr imaging needs
sYstem reqUirements
IMaGE INfORMaTION SYSTEMS lTd.OffIcE 404, 4Th flOOR | alBaNY hOuSE | 324/326 REGENT STREET | lONdON w1B 3hh | uNITEd KINGdOM
TEl. uK: +44 207 193 06 20 | TEl. GER: +49 381 496 5820 | TEl. uS: +1 704 323 6663 faX uK: +44 207 976 48 97 | faX GER: +49 381 496 582 99 | faX uS: +1 704 945 7101
www.IMaGE-SYSTEMS.BIz | [email protected]
hardWare & softWare reqUirementsSERVER MINIMuM SERVER (REcOMMENdEd) clIENT MINIMuM
clIENT (REcOMMENdEd)
OS: Windows Server 2003 Windows Server 2008Windows Server 2008 R2
Windows XP PRO Windows 7 PRO
cPu: Single Core 2.0 GHz Dual or Multi Core 1.8 GHz Single Core 1.8 GHzDual Core 1.8 GHz*
Dual Core 1.8 GHzIntel Core i7*
RaM: 2048 MB 4096 MB 1024 MB3072 MB*
2048 MB4096 MB*
hdd: 80 GB NTFS RAID > 160 GB NTFS 10 GB 80 GB
Network: 10 Mbit/s 100 Mbit/s 1 Mbit/s(if local RIS client)
100 Mbit/s
Graphics: 16 bit color output 24 bit color output 16 bit color output 24 bit color output
Display: 1280 x 800 pixels 1440 x 900 pixels or more 1280 x 800 pixels 1440 x 900 pixelsor more
Database: Postgre SQL 8.2.21 Postgre SQL 8.2.21
iQ-VIEw: Version 2.7.0 Version 2.7.0
MS Word: Version 2003 Version 2007Version 2010 32 bit
hardware: Dell Dell
*iQ-VOICE System Requirements (excluding iQ-VOICE WORKFLOW - available on request); CPU pro-cessor cache: minimum 512 KB, recommended 2 MB