road lighting pelindo iii gresik section row 22 type a
DESCRIPTION
LTRANSCRIPT
![Page 1: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/1.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE ADate: 05-02-2012
Designer: Syaiful Fikri
CalcuLuX Road 7.6.1.0
The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixedrelationship to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminairepositioning, reflection properties and electrical supply.
![Page 2: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/2.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
1. Project Description
1.1 3-D Project Overview
C BRP372 LED141NW 150W 22
C
C
X
YZ
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 2/17
![Page 3: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/3.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
1.2 Top Project Overview
C BRP372 LED141NW 150W 22
-16 -11 -6 -1 4 9 14 19 24
X(m)
-6-1
49
1419
2429
3439
44Y
(m)
C
C
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 3/17
![Page 4: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/4.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
2. Summary
2.1 Main Road
Luminaire Type : BRP372 LED141NW 150W 220-240V DM2ELamp Type : 1 * Luxeon R x72LEDs Ra75.1Lamp Flux : 15163 lumenTilt90 (T) : 5.0 degGrid Method : CEN LuminanceProject Maintenance Factor : 0.90
T
O
H
W
S
Carriageway : Single CarriagewayRoad Width (W) : 10.00 mNumber of Lanes : 3Reflection Table : CIE C1Q0 of Table : 0.100Maintenance Factor : 0.90Installation : Single Sided LeftHeight (H) : 13.00 mSpacing (S) : 40.00 mOverhang (O) : 2.00 m
Overall quality figures for the above road scheme.
LuminanceAverage = 1.71 cd/m2Minimum = 1.22 cd/m2Maximum = 2.43 cd/m2Minimum/Maximum = 0.50Minimum/Average = 0.69Ul = 0.60
GlareTI = 5.9 %
Horizontal IlluminanceAverage = 17.1 luxMinimum = 9.9 luxMaximum = 26.3 luxMinimum/Maximum = 0.37
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 4/17
![Page 5: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/5.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3. Calculation Results
3.1 Main L (O1): Graphical Table
TI ( 1.67,-31.63, 1.50) = 5.4%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O1) (1.67,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.71 0.75 0.53 0.90
C BRP372 LED141NW 150W 22
-16 -11 -6 -1 4 9 14 19 24
X(m)
-41
611
1621
2631
3641
Y(m
)
C
C
1.7
1.6
1.5
1.4
1.4
1.3
1.3
1.3
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.7
1.6
1.5
1.4
1.3
1.3
1.3
1.4
1.5
1.6
1.7
1.8
1.8
2.0
1.8
1.7
1.6
1.5
1.4
1.3
1.4
1.4
1.6
1.6
1.8
1.9
2.0
2.1
2.0
1.8
1.6
1.6
1.4
1.4
1.4
1.4
1.6
1.7
1.9
2.0
2.1
2.3
2.1
1.8
1.7
1.6
1.5
1.4
1.5
1.5
1.7
1.7
1.9
2.1
2.3
2.3
2.1
1.9
1.7
1.6
1.5
1.5
1.5
1.6
1.7
1.8
2.0
2.2
2.3
2.4
2.2
1.9
1.7
1.6
1.5
1.5
1.5
1.6
1.7
1.9
2.1
2.3
2.4
2.3
2.1
1.9
1.7
1.6
1.5
1.4
1.5
1.5
1.7
1.8
2.0
2.3
2.4
2.1
2.0
1.7
1.5
1.4
1.3
1.3
1.3
1.4
1.5
1.7
1.9
2.1
2.2
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 5/17
![Page 6: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/6.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.2 Main L (O1): Iso Contour
TI ( 1.67,-31.63, 1.50) = 5.4%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O1) (1.67,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.71 0.75 0.53 0.90
C BRP372 LED141NW 150W 22
-16 -11 -6 -1 4 9 14 19 24
X(m)
-41
611
1621
2631
3641
Y(m
)
1.5
1.5
1.75
1.75
2
2
2
2.25
2.25
C
C
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 6/17
![Page 7: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/7.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.3 Main L (O1): Filled Iso Contour
TI ( 1.67,-31.63, 1.50) = 5.4%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O1) (1.67,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.71 0.75 0.53 0.90
C BRP372 LED141NW 150W 22
2.25
2
1.75
1.5
-10 -5 0 5 10 15 20
X(m)
-41
611
1621
2631
3641
Y(m
)
C
C
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 7/17
![Page 8: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/8.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.4 Main L (O2): Graphical Table
TI ( 5.00,-31.63, 1.50) = 5.9%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O2) (5.00,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.74 0.72 0.51 0.90
C BRP372 LED141NW 150W 22
-16 -11 -6 -1 4 9 14 19 24
X(m)
-41
611
1621
2631
3641
Y(m
)
C
C
1.7
1.7
1.5
1.4
1.4
1.3
1.3
1.3
1.4
1.5
1.5
1.6
1.7
1.7
1.9
1.8
1.6
1.5
1.5
1.4
1.4
1.4
1.4
1.6
1.6
1.7
1.8
1.9
2.0
1.9
1.7
1.6
1.6
1.4
1.4
1.4
1.5
1.6
1.7
1.8
1.9
2.0
2.2
2.0
1.8
1.7
1.6
1.5
1.4
1.5
1.5
1.7
1.8
1.9
2.1
2.2
2.3
2.1
1.9
1.7
1.6
1.5
1.5
1.5
1.6
1.7
1.8
2.0
2.2
2.4
2.4
2.2
1.9
1.7
1.7
1.5
1.5
1.5
1.6
1.8
1.9
2.1
2.3
2.4
2.4
2.2
1.9
1.7
1.6
1.5
1.5
1.5
1.6
1.8
1.9
2.1
2.3
2.5
2.3
2.1
1.8
1.7
1.5
1.4
1.4
1.4
1.5
1.6
1.8
2.0
2.2
2.3
2.1
1.9
1.7
1.5
1.4
1.3
1.3
1.3
1.3
1.5
1.6
1.8
2.0
2.1
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 8/17
![Page 9: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/9.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.5 Main L (O2): Iso Contour
TI ( 5.00,-31.63, 1.50) = 5.9%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O2) (5.00,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.74 0.72 0.51 0.90
C BRP372 LED141NW 150W 22
-16 -11 -6 -1 4 9 14 19 24
X(m)
-41
611
1621
2631
3641
Y(m
)
1.5
1.51.
75
1.75
2
2
2
2.25
2.25
C
C
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 9/17
![Page 10: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/10.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.6 Main L (O2): Filled Iso Contour
TI ( 5.00,-31.63, 1.50) = 5.9%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O2) (5.00,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.74 0.72 0.51 0.90
C BRP372 LED141NW 150W 22
2.25
2
1.75
1.5
-10 -5 0 5 10 15 20
X(m)
-41
611
1621
2631
3641
Y(m
)
C
C
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 10/17
![Page 11: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/11.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.7 Main L (O3): Graphical Table
TI ( 8.33,-31.63, 1.50) = 5.2%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O3) (8.33,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.75 0.69 0.50 0.90
C BRP372 LED141NW 150W 22
-16 -11 -6 -1 4 9 14 19 24
X(m)
-41
611
1621
2631
3641
Y(m
)
C
C
1.7
1.7
1.5
1.5
1.4
1.4
1.4
1.4
1.5
1.5
1.6
1.6
1.8
1.8
1.9
1.8
1.6
1.6
1.5
1.4
1.4
1.4
1.5
1.6
1.7
1.8
1.9
1.9
2.0
1.9
1.8
1.6
1.6
1.5
1.4
1.5
1.5
1.7
1.8
1.9
2.0
2.1
2.2
2.0
1.8
1.7
1.7
1.5
1.5
1.5
1.6
1.8
1.8
2.0
2.2
2.3
2.4
2.2
1.9
1.7
1.7
1.5
1.5
1.5
1.6
1.8
1.9
2.1
2.3
2.4
2.4
2.2
1.9
1.7
1.7
1.6
1.5
1.6
1.6
1.8
1.9
2.1
2.3
2.4
2.4
2.2
1.9
1.7
1.6
1.5
1.5
1.5
1.6
1.7
1.8
2.0
2.2
2.4
2.3
2.1
1.8
1.6
1.5
1.4
1.4
1.4
1.5
1.6
1.7
1.9
2.1
2.2
2.1
1.9
1.7
1.5
1.4
1.3
1.2
1.2
1.3
1.4
1.6
1.7
1.9
2.1
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 11/17
![Page 12: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/12.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.8 Main L (O3): Iso Contour
TI ( 8.33,-31.63, 1.50) = 5.2%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O3) (8.33,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.75 0.69 0.50 0.90
C BRP372 LED141NW 150W 22
-16 -11 -6 -1 4 9 14 19 24
X(m)
-41
611
1621
2631
3641
Y(m
) 1.25
1.5
1.51.
75
1.75
2
2
2
2
2.25
2.25
C
C
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 12/17
![Page 13: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/13.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.9 Main L (O3): Filled Iso Contour
TI ( 8.33,-31.63, 1.50) = 5.2%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O3) (8.33,
-60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100
Average Min/Ave Min/Max Project maintenance factor 1.75 0.69 0.50 0.90
C BRP372 LED141NW 150W 22
2.25
2
1.75
1.5
1.25
-10 -5 0 5 10 15 20
X(m)
-41
611
1621
2631
3641
Y(m
)
C
C
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 13/17
![Page 14: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/14.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.10 Main Eh: Graphical Table
Grid : Main at Z = -0.00 mCalculation : Horizontal Illuminance (lux)
Average Min/Ave Min/Max Project maintenance factor 17.1 0.58 0.37 0.90
C BRP372 LED141NW 150W 22
-16 -11 -6 -1 4 9 14 19 24
X(m)
-6-1
49
1419
2429
3439
44Y
(m)
C
C
20
19
17
16
15
13
13
13
13
15
16
17
19
20
22
20
18
16
15
13
13
13
13
15
16
18
20
22
23
21
19
16
15
13
12
12
13
15
16
19
21
23
24
22
19
16
15
13
12
12
13
15
16
19
22
24
25
23
19
16
15
13
12
12
13
15
16
19
23
25
26
23
20
16
15
12
12
12
12
15
16
20
23
26
26
23
20
16
14
12
11
11
12
14
16
20
23
26
26
23
19
16
14
12
11
11
12
14
16
19
23
26
24
22
18
15
13
11
10
10
11
13
15
18
22
24
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 14/17
![Page 15: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/15.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.11 Main Eh: Iso Contour
Grid : Main at Z = -0.00 mCalculation : Horizontal Illuminance (lux)
Average Min/Ave Min/Max Project maintenance factor 17.1 0.58 0.37 0.90
C BRP372 LED141NW 150W 22
-16 -11 -6 -1 4 9 14 19 24
X(m)
-6-1
49
1419
2429
3439
44Y
(m) 10
12.5
15
15
17.5
17.5
20
2022.5
22.5
25
25
C
C
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 15/17
![Page 16: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/16.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
3.12 Main Eh: Filled Iso Contour
Grid : Main at Z = -0.00 mCalculation : Horizontal Illuminance (lux)
Average Min/Ave Min/Max Project maintenance factor 17.1 0.58 0.37 0.90
C BRP372 LED141NW 150W 22
25
22.5
20
17.5
15
12.5
10
-10 -5 0 5 10 15 20
X(m)
-6-1
49
1419
2429
3439
44Y
(m)
C
C
Scale1:250
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 16/17
![Page 17: Road Lighting Pelindo III Gresik Section Row 22 Type A](https://reader036.vdocument.in/reader036/viewer/2022082610/563db996550346aa9a9ebdeb/html5/thumbnails/17.jpg)
ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 22 TYPE A Date: 05-02-2012
4. Luminaire Details
4.1 Project Luminaires
Xceed Medium FOT Sample(72LED700)BRP372 LED141NW 150W 220-240V 1xLuxeon R x72LEDs Ra75.1/3934
Light output ratios DLOR : 1.00 ULOR : 0.00 TLOR : 1.00Ballast : 700mA Global DriverLamp flux : 15163 lmLuminaire wattage : 154.0 WMeasurement code : LVC1121498
Note: Luminaire data not from database.
750
750
0o 30o30o
60o 60o
90o 90o
120o 120o150o 150o180o
C = 180o C = 0o C = 270o C = 90o C = 195o Imax C = 15o
Luminous Intensity Diagram (candela/1000 lumen)
Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 17/17