Room for flexibility The EasyDiagnost Eleva is a R/F system designed to perform a wide range of applications from gastro-intestinal, various iodine and vascular procedures to standard radiography. By combining the EasyDiagnost Eleva with a choice of a vertical stand and/or a digital detector in the table you can create your own 2-in-1 room solution. Set up a radiography and fluoroscopy room that perfectly fits your needs – from a single detector version to a high-end full digital room solution with all advantages of filmless and even cassetteless workflow. Philips EasyDiagnost Eleva with digital Radiography/Fluoroscopy room solutions to combine both applications in one room

Upload: others

Post on 02-Jan-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Room for flexibility

The EasyDiagnost Eleva is a R/F system designed to perform a wide range of

applications from gastro-intestinal, various iodine and vascular procedures to

standard radiography. By combining the EasyDiagnost Eleva with a choice of a

vertical stand and/or a digital detector in the table you can create your own

2-in-1 room solution. Set up a radiography and fluoroscopy room that perfectly

fits your needs – from a single detector version to a high-end full digital room

solution with all advantages of filmless and even cassetteless workflow.

Philips EasyDiagnost Eleva with digital Radiography/Fluoroscopy room solutions to combine both applications in one room

Content

04 Main components and options

06 EasyDiagnost Eleva

09 DoseWise

10 X-ray generation

12 Image detection

13 Image display

14 Eleva workspot

16 Extended Digital Imaging

20 Over-table technique

22 Digital vertical stand VS

24 Vertical stand VS advanced

26 Ceiling suspension CS

27 Height adjustable trolley TA-M

29 Image plate reader PCR Eleva S Plus

30 DRF room solution – Configuration proposals

32 Room planning

35 General

Main components and options*

EasyDiagnost Eleva ✓

Spot-film device (Digital Camera) ✓

Under-table X-ray tube assembly ✓

Tube lift ❍

Image detection, incl. image intensifier and TV camera ✓

Image display, incl. Eleva Examination Control ✓

LCD monitor in examination room ✓

Monitor trolley for LCD monitor ✓

Ceiling suspension for one or two LCD monitors ❍

Eleva workspot ✓

Extended Digital Imaging, incl. image processing and storage with ViewForum ✓

Angiography (with Bolus Chase) ❍

Footswitch for fluoroscopy and exposure ✓

Accessories ✓/❍

DoseWise ✓/❍

High voltage generator Velara RF ✓

DICOM Worklist Management ❍

DICOM MPPS ❍

DICOM image export ✓

DICOM print ✓

DICOM Media on CD-R ❍

mShield ✓

Bucky tray ❍

EasyLat ❍

Digital in-table detector ❍

� ✓ = standard ❍ = optional

Main components and options

* Please contact your local sales specialist for additional system extensions and accessories

Main components and options

Ceiling suspension with X-ray tube assembly with control grip and collimator (CS2/4)

Digital vertical stand VSMotorized tilting – 20º to +90ºDigital flat detectorRemovable gridAutomatic exposure control (AEC)� AEC measuring fieldsTrackingAutomatic image stitching incl. Patient supportServo supported CS movements (with automatic image stitching)

Vertical stand VS advancedMotorized tilting – 20º to +90ºCassette trayRemovable gridAutomatic exposure control (AEC)� AEC measuring fields

Tracking (detector in vertical stand with tilt)

Height adjustable trolley TA-M ❍

UNIQUE image processing ✓

Reject analysis ❍

PCR Eleva S Plus ❍

Integration in existing PCR Eleva network ❍

Philips CAD Chest solution xLNA ❍

✓ = standard❍ = optional

The EasyDiagnost Eleva stand

consists of:

• Table

• Cassette tray, digital detector unit or

EasyLat (option)

• Spot-film device (Digital Camera)

• Compressor

• Tube assembly

• Tube lift (option)

Table

DimensionsTable heightTable top

8�0 mm2,000 mm x �90 mm

(�2.7")(78.7" x 27.2")

Table tiltTilt angle

Speed

90° / –20°90° / –�0°90° / –��°90° / –8�°1°/s to �°/s variable

Table top

MovementsLateralLongitudinal

–100 mm to +90 mm±8�0 mm

(–�.9" to +�.�")(±��")

Movement speedLateralLongitudinalwith bolus chase acquisition

�2 mm/s�0 mm/s0–1�0 mm/s

(1.7"/s)(2.�"/s)(0–�.9"/s)

X-ray attenuation aquivalent0.7 mm Al typical(at 100 kV, 2.7 mm Al HVL)

Maximum patient weightfor all movementsstatic, in horizontal or verticaltable position (incl. footrest)

180 kg2�0 kg

(�00 lbs)(��0 lbs)

✓✓ = standard❍ = optional

EasyDiagnost Eleva

7

All dimensions in mm (feet/inches)

2115

(6'

11.

3")

2950

(9'

8.1

")

1558 (5' 1.3")

1775

(5'

9.9

")

1500 (4' 11.1")1075 (3' 6.3")

554

(21.

8")

2399

for

23 c

m I.

I. (7

' 10.

5" fo

r 9"

I.I.)

2390

for

38 c

m I.

I.

(7' 1

0.1"

for

15"

I.I.)

2950

(9'

8.1

")750

(29.5")340

(13.4") 520(20.5")

1340 (4' 4.8")

620 (24.4")

film

38 cm I.I. (15")

975 (38.4") 1

2000 (6' 6.7")

835 (32.9")

835 (32.9")

690

(27.

2")

100

(3.9

")85

(3

.3")

554

(21.

8")

833

(32.

8")

max

. 210

4 (m

ax. 6

' 10.

8")

626

(24.

6")

155

(6.1

")49

0(1

9.3"

)

512

190

750

(29.

5")

140

1075 (3' 6.3") 885 mm (34.8") – with EasyLat

108.5 108.5 (4.3")

1000 (3' 3.4")

1

2115

(6'

11.

3")

2950

(9'

8.1

")

1558 (5' 1.3")

1775

(5'

9.9

")

1500 (4' 11.1")1075 (3' 6.3")

554

(21.

8")

2399

for

23 c

m I.

I. (7

' 10.

5" fo

r 9"

I.I.)

2390

for

38 c

m I.

I.

(7' 1

0.1"

for

15"

I.I.)

2950

(9'

8.1

")

2115

(6'

11.

3")

2950

(9'

8.1

")

1558 (5' 1.3")

1775

(5'

9.9

")

1500 (4' 11.1")1075 (3' 6.3")

554

(21.

8")

2399

for

23 c

m I.

I. (7

' 10.

5" fo

r 9"

I.I.)

2390

for

38 c

m I.

I.

(7' 1

0.1"

for

15"

I.I.)

2950

(9'

8.1

")

8

Spot-film device (Digital Camera)

MovementsLateralParkingLongitudinal

220 mm�20 mm7�0 mm

(8.7")(20.�")(29.�")

Gridwithout tube lift option

with tube lift option

�0 l/cmr = 10:1, fo = 800 mm�0 l/cmr = 10:1, fo = 900 mm

Grid parking Automatic movement to parking position ✓

Compressor

Compression cone Integrated in spot-film device ✓

Compression movement �0� mm (12") ✓

Compression stop 10 steps, manually selectable ✓

Compression pressure servo supported ✓

Tube lift (option)

Speed �0 mm/s (2"/s) ✓

Focus – Table top distance �10 mm to ��0 mm (20" to 2�.�") ✓

✓ = standard❍ = optional

EasyDiagnost Eleva (contd.)

750 (29.5")

340 (13.4") 520

(20.5")

1340 (4' 4.8")

620 (24.4")

film

38 cm I.I. (15")

975 (38.4") 1

2000 (6' 6.7")

835 (32.9")

835 (32.9")

690

(27.

2")

100

(3.9

")85

(3

.3")

554

(21.

8")

833

(32.

8")

max

. 210

4 (m

ax. 6

' 10.

8")

626

(24.

6")

155

(6.1

")49

0(1

9.3"

)

512

190

750

(29.

5")

140

1075 (3' 6.3") 885 mm (34.8") – with EasyLat

108.5 108.5 (4.3")

1000 (3' 3.4")

1

All dimensions in mm (feet/inches)

750 (29.5")

340 (13.4") 520

(20.5")

1340 (4' 4.8")

620 (24.4")

film

38 cm I.I. (15")

975 (38.4") 1

2000 (6' 6.7")

835 (32.9")

835 (32.9")

690

(27.

2")

100

(3.9

")85

(3

.3")

554

(21.

8")

833

(32.

8")

max

. 210

4 (m

ax. 6

' 10.

8")

626

(24.

6")

155

(6.1

")49

0(1

9.3"

)

512

190

750

(29.

5")

140

1075 (3' 6.3") 885 mm (34.8") – with EasyLat

108.5 108.5 (4.3")

1000 (3' 3.4")

1

9

DoseWise

✓ = standard❍ = optional

Less radiation time

FluoroGrab ✓

Dynamic FluoroGrab (filming) ✓

Preset collimation ✓

Collimation on LIH ✓

Automatic parameter setting ✓

High resolution LCD monitor (flicker-free) ✓

More awareness

Dose calculation ✓

Dose measurement ❍

Dose display ✓

Dose reporting ✓

X-ray disable function ✓

X-ray shieldingfixed and flexible lead curtains againstscattered radiation

Smart beam

Pulsed Fluoroscopy (PF), In-pulse controlled ❍

Grid Controlled Fluoroscopy (GCF), In-pulse controlled

Intelligent Exposure (IQX), In-pulse controlled ✓

SpectraBeam RF ✓

Adaptive Measuring Field ✓

Tube lift ❍

Iris shutter and two pairs of parallel shutters ✓

Parkable Grid (in spot-film device) ✓

✓ = standard❍ = optional

10

X-ray generation

Generator Velara RF

Power pack �0 kW�� kW80 kW

Tube support SRO 2��0SRM 22�0 GSSRO ��100 (for CS)

Exposure techniques • Manual: kV-mAs or kV-mA-s• Automatic Exposure Control (AEC), based on

falling load and fixed current techniques• Intelligent Exposure (IQX), In-Pulse controlled• Automatic kV reduction techniques

Fluoroscopy techniques • Automatic kV/mA control during fluorscopy• Pulsed Fluoroscopy (PF), In-pulse controlled• Grid Controlled Fluoroscopy (GCF),

In-pulse controlled

Tube voltage exposureTube voltage fluoroscopy

�0 to 1�0 kV�0 to 110 kV

Tube current exposureTube current fluoroscopy

1 to 1100 mA0.2 to � mA

depending on power pack

mAs product 0.� to �00 mAs0.� to 8�0 mAs

with AECwithout AEC

Exposure times 1 ms to � s with AEC

Access times (tube dependent)Standby to fluoroscopyFluoroscopy to radiographyRadiography to fluoroscopy

< 0.� s< 0.8 s< 0.8 s

Dose managementDose calculationDose measurement

Entrance dose, entrance dose rate, dose-area productDose-area product

Safety Tube overload protectionAutomatic mains voltage compensation

✓ = standard❍ = optional

Integrated generator

control

11

Tube SRO 2550 SRM 2250 GS SRO 33100 (for CS)

Focal spot 0.� / 1.0 0.� / 1.0 0.� / 1.0

Anode diameter 90 mm 100 mm 90 mm

Anode angle 1�º 1�º 1�º

Anode heat storage capacity �00 kHU (220 kJ) �80 kHU (280 kJ) �80 kHU (280 kJ)

Maximum voltage 1�0 kV 12� kV 1�0 kV

Max. continuous heat dissipation 2�0 W �00 W 2�0 W

Max. heat content of assembly 1700 kHU (12�0 kJ) 20�0 kHU (1�10 kJ) 1700 kHU (12�0 kJ)

Grid switch No Yes No

Collimator for Under-table technique Over-table technique

Collimator controlBuilt-in µ-controller and motor controllersPower-up self testAuto calibration at power-upError logging, reporting

✓ ✓

SpectraBeam RFProgrammable filter pre-setsMax. number of pre-filters

�✓

Rectangular collimationMotor drivenTwo pairs of parallel shuttersMax. opening �1 cm (20")Positioning accuracy 0.�% of SID

✓ ✓

Circular collimationOctagonal ShapeMotor drivenPositioning accuracy 0.�% of SID

✓ –

Collimation on LIHFor regular shuttersOn last fluoroscopy imageOn last exposure image

–––

✓ = standard❍ = optional

12

Image Intensifier (I.I.)

Mode2�0 mm, 170 mm, 1�0 mm �10 mm, 2�0 mm, 200 mm, 170 mm�80 mm, �10 mm, 2�0 mm, 170 mm

(9", 7", �.�") or(12", 10", 8", 7") or(1�", 12", 10", 7")

Input window Titanium

Detective Quantum Efficiency ��%

Modulation Transfer Factor ��% at 1 lp/mm in �8 cm (1�'') mode

Central spatial resolution �80 mm (1�'') mode:170 mm (�.7'') mode:

� lp/mm (1�.7 lp/ '')� lp/mm (2�.� lp/ '')

Conversion factor in �8 cm (1�'') mode,typical

�00 cd/m2/(mR/s); ��,8 cd/m2/(µGy/s)

Structure noise Negligible

Contrast ratio170 mm (�.7'') (10% disc): �80 mm (1�'') (10% disc):

��:122:1

Image detection

Camera

Type CCD

Matrix 102� x 102� and �12 x �12

Dynamic range Between �� and 70 dB

Digital output 12 bit

Horizontal / Vertical scan reverse

Yes

Dose control, automatic In-pulse controlled

Automatic Gain Control In-frame gain control

Measurement fields 2 fields configurable

Application range (dose) � to 10 000 nGy/image

1�

Image display

Monitor

Type LCD (Liquid Crystal Display) ✓

Monochrome display ��0 mm (18 ) ✓

Progressive display (flicker free) ✓

Native format 1280 x 102� SXGA ✓

Nominal brightness �00 Cd/m2 ✓

Monitor carriers

Trolley for one LCD monitorfor two LCD monitors

Ceiling suspension for one LCD monitorfor two LCD monitors

✓ = standard❍ = optional

1�

Eleva workspot

✓ = standard❍ = optional

Eleva workspot

Hard disk • 1�0 GB total• 108 GB for the image data (up to approximately �,700 images)

RAM storage capacity 2 GB

Interfaces • Ethernet 10/100/1000 Base-T Gigabit• DICOM interface• Detector interface• Memory stick support for QC

CD writer �8x CD/DVD reader, CD writer

Monitor 19''-LCD color touchscreen monitor EEC-A ✓with hardware frame for ergonomic workflow

19''-LCD color touchscreen monitor EEC-E ❍(space saving, recommended just for configurations without second plane)

Keyboard with mouse and function buttons

For entering administrative patient data and for operating the screen menus

Barcode reader Error free input of patient data ❍and patient selection

Generator control Integrated ✓EPX-programmed ✓

Image data

Data volume Up to 18 MB/image

Matrix depth 1� bit/pixel

1�

468 (18.4")

510.

75 (

20.1

")34

2 (1

3.5"

)

456.75 (18.0")

All dimensions in mm (feet/inches)

293 (11.5")

61 (2.4")

386

(15.

2")

207 (8.2")

23 (2.4")

All dimensions in mm (feet/inches)

429 (16.9")35

9 (1

4.1"

)

EEC-A EEC-E

1�

Extended Digital Imaging

Fluoroscopy

Digital high resolution continuous fluoroscopy ✓

Grid Controlled Fluoroscopy: 0,�-�0 pulses/sec (�0/�0Hz) ❍

Pulsed fluoroscopy, 0,�-� pulses/sec (�0/�0Hz) ❍

FluoroGrab ✓

Dynamic FluoroGrab (up to �0 images/sec) ✓

Fluoro images freeze (last image hold) ✓

Trace subtract fluoroscopy ❍

Dynamic noise reduction ✓

Acquisition

First time right IQ with harmonization and auto windowing ✓

Matrix size 102�2 and �122 ✓

Acquisition speed: up to 8 images/sec (102�2 and �122) ✓

Acquisition speed: up to �0 images/sec (�122) ❍

Adjustable acquisition speed (during run) ✓

Live subtraction ❍

Standard acquisition RAM capacity (0.� GB) ✓

Max. acquisition RAM capacity (1 GB) ❍

External video display ✓

Bolus chase (non subtracted) ❍

✓ = standard❍ = optional

17

Image processing

Harmonization ✓

Processing depth (bit) 1�

Video invert ✓

Zoom variable up to x �.7 ✓

Magnifying glass and panning ✓

Manual adjustable contrast/brightness/edge enhancement ✓

Electronic shutters (automatic & manual) ✓

Flip/rotate ✓

Annotation 'free text and advanced' ✓

Measurements: length, angle and area ✓

Vascular image processing

Subtract (single mask) ❍

Run subtract (multiple mask) ❍

Measurements extended: area, histogram, vessel analysis (automatic) ❍

Re-masking ❍

Pixel shift ❍

Split screen pixel shift ❍

Auto warp (automatic pixel shift) ❍

Land marking/road mapping: acquisition ❍

View trace (max. opacification) ❍

CO2 imaging (min. opacification) ❍

✓ = standard❍ = optional

18

Viewing

View switch time between patients stored in RAM: 0.1 sec ✓

View switch time between runs stored in RAM (within one patient): 0.1 sec ✓

Dynamic view & run cycle: up to �0 fps ✓

Overview (user selectable number of images) ✓

Pictorial index ✓

Parallel working ❍

Multimodality viewing (CT/MR/…) in control- and exam room ❍

Direct Mouse Manipulation (DMM) ✓

Default display protocols ✓

User log-on ✓

Image storage

Hard disk ✓

DVD/CD-recordable (background storage and retrieval) ❍

Flagging for selective storing, printing and export of images ✓

(Automatic) export of image to network servers (e. g. PACS) ❍

Image reconstruction

ColonMap (complete abdominal overview) ❍

Bolus Chase Reconstruction (complete overview of peripheral vasculature) ❍

✓ = standard❍ = optional

Extended Digital Imaging (contd.)

19

Printing

DICOM Print SCU ✓

Paper printing ✓

Manual compose print (user dependent layout) ✓

Protocol print (user selects layout from a list) ✓

Auto protocol print ✓

Print protocol editor ❍

Automatic annotation of hardcopies ✓

Networking

DICOM store SCP ✓

DICOM store SCU/SCP ❍

DICOM storage commit SCU ❍

DICOM query/retrieve SCU/ SCP ❍

DICOM worklist management SCU ❍

DICOM MPPS SCU ❍

DICOM presentation state ✓

DICOM grey scale display standard ✓

Multitasking (background communication) ✓

Serviceability❍

Remote service support ✓

Digital image quality measurement tool ✓

✓ = standard❍ = optional

20

Over-table technique

EasyLat

Type Fold-out cassette holder forhigh quality lateral exposures

Amplimat measuring chamber ✓

Cassette-size sensing ✓

Grid 70 l/cm, r = 1�:1,f0 = 110 cm, stationary

Cassette formatsfold-in

fold-out

1� cm x 18 cm to �� cm x �� cm(�" x 7" to 1�" x 17")�� cm x �� cm to �� cm x �� cm(1�" x 1�" to 1�" x 17")

✓ = standard❍ = optional

All dimensions in mm (feet/inches)

900 (35.4")

min

. cei

ling

heig

ht 2

720

(8' 1

1.1"

) *

min

. 860

(33

.9")

mov

emen

t ra

nge

0...1

480

(4' 1

0.3"

)

mov

emen

t ra

nge

0...1

495

(4' 1

0.9"

) (w

ithou

t ß-

stop

)m

in. 8

45 (

33.3

")

(with

out

ß-st

op)

max

. 234

0 (7

' 8.1

")38

0(1

5")

1200 (3' 11.2")

510

(20.

1")

1500 (4' 11.1")2653 (8' 8.5")

3000 (9' 10.1")

2000 (6' 6.7")1322 (4' 4.1") 1678 (5' 6.1")

1875 (6' 1.8")1090 (3' 6.9")

588(23.1")

375(14.8")

72(2.8")

Bucky unit in table

Amplimat measuring chamber ✓

Automatic cassette size sensing ✓

Removable grid Choice of � exchangable

oscillating grid types

Cassette formats 1� cm x 18 cm to �� cm x �� cm(�'' x 7'' to 1�'' x 17'')

✓ = standard❍ = optional

Digital detector unit

Amplimat measuring chamber ✓

Preset collimation ✓

Exam-type dependent collimation presets ✓

Type Flat detector made of amorphous silicon

Detector size �� cm x �� cm (17" x 17")

Image matrix size �,000 pixels x �,000 pixels

Pixel size 1�� µm

Image resolution up to �.� Lp/mm

Dimension �9� mm x �7� mm x 18� mm

(2�.�" x 22.�" x 7.2")

Removable grid Choice of � exchangable oscillating

grid types

✓ = standard❍ = optional

21

Digital vertical stand VS

Column

Hardware Counterbalanced rugged column for motorized and manual vertical movement of the detector unit

Vertical movement range �00 mm to 1,800 mm (center beam) (11.8" to �’11")

Installation Floor and wall attachment or floor only (option)

Grips

Two patient grips On left and right of the detector unit

Patient stretch grip (option)

• Arranged on left or right of the detector unit• Rotatable

Brakes

Brakes Electromagnetic, self-locking

22

Detector unit

Type Flat detector made of amorphous silicon

Detector size �� cm x �� cm (17" x 17")

Image matrix size �,000 pixels x �,000 pixels

Pixel size 1�� µm

Image resolution up to �.� Lp/mm

Dimension �9� mm x �7� mm x 18� mm (2�.�" x 22.�" x 7.2")

Angle of tilt (option)

– 20º to +90º, motorized tilting

Automatic exposure control (AEC)

� AEC measuring fields

Weight approx. 2�.� kg (�8.� lbs)

Removable grid Choice of � exchangable

oscillating grid types

Grid storage For up to 2 grids within the detector unit

Digital vertical stand VS

with/without tilt

2�

The digital vertical stand VS

consists of:

• Column

• Detector unit

• Grid

• 2 user interfaces (left & right)

• 2 patient grips (left & right)

• Vertical stand display

All dimensions in mm (feet/inches)

64 (2.5") 107 (4.2")

575

(22.

6")

406 (16")710 (28")

825

(32.

5")

1173

(3'

10.

2")

1819

(5'

11.

6")

596 (23.5") 227 (8.9")

160(6.3")

1990

(6'

6.3

")20

80 (

6' 9

.9")

≤150

0 (4

' 11.

1")

≥300

(11.

8")

≤210

5 (6

' 10.

9")

543 (21.4")

dete

ctor

pla

ne

Buck

y un

it fr

ont

side

596

(23.

5")

50 (2.0") 54 (2.1")

902

(35.

5")

1286 (4' 2.6")

dete

ctor

pla

ne

Buck

y un

itfr

ont

side

596

(23.

5")

300(11.8")

902

(35.

5")

with spacer (option)

spacer

64 (2.5")107 (4.2")

1990

(6'

6.3

")20

80 (

6' 9

.9")

986 (38.9")

596

(23.

5")

120

(4.7

")

902

(35.

5")

712 (28.1")

20°

≥300

≤150

0 (4

' 11.

1")

≤210

5 (6

' 10.

9")

≥549

(21.

6")

dete

ctor

pla

ne

Buck

y un

itfr

ont

side

54 (2.1")

with tilting (option)

with tilting (option)

2�

Vertical stand VS advanced

Column

Hardware Counterbalanced rugged column for motorized and manual vertical movement of the detector unit

Vertical movement range �00 mm to 1,800 mm (center beam) (11.82" to �'10.87")

Installation Floor and wall attachment or floor only (option)

Grips

Two patient grips On left and right of the detector unit

Patient stretch grip(option)

• Arranged on left or right of the detector unit• Rotatable

Brakes

Brakes Electromagnetic, self-locking

Vertical stand VS advanced

with/without tilt

Detector unit (cassette tray)

Dimensions (w x h) �9� mm x �7� mm x 18� mm (2�.�" x 22.�" x 7.2")

Angle of tilt (option) – 20º to +90º, motorized tilting

Automatic exposure control (AEC)

� AEC measuring fields

Operating 2 control units (left & right)

Removable grid Choice of � exchangable oscillating grid types

Grid storage For up to 2 grids within the detector unit

Cassette formats 18 cm x 2� cm to �� cm x �� cm(8" x 10" to 1�" x 17")

2�

Column

Hardware Counterbalanced rugged column for motorized and manual vertical movement of the detector unit

Vertical movement range �00 mm to 1,800 mm (center beam) (11.82" to �'10.87")

Installation Floor and wall attachment or floor only (option)

Grips

Two patient grips On left and right of the detector unit

Patient stretch grip(option)

• Arranged on left or right of the detector unit• Rotatable

Brakes

Brakes Electromagnetic, self-locking

All dimensions in mm (feet/inches)

The vertical stand VS advanced

consists of:

• Column

• Detector unit (cassette tray)

• Grid

• 2 user interfaces (left & right)

• 2 patient grips (left & right)

64 (2.5")

107 (4.2")

139 (5.5")

50 (2.0")

Ref. cross point

543 (21.4")

fron

t si

de b

ucky

uni

t

cass

ette

film

pla

ne

902

(35.

6")

120

(4.7

")19

90 (

6' 6

.3")

2080

(9'

2.2

")

max

. 150

0 (4

' 11.

1")

max

. 210

5 (6

' 10.

9")

min

. 300

(11

.9")

1) space for cassette and grid exchange

139 (5.5") 54 (2.1")

spacerRef. cross point

1286 (4' 2.6")

300 (11.9")

902

(35.

5")

fron

t si

de b

ucky

uni

t

cass

ette

film

pla

ne

120

(4.7

")

1173

(3'

10.

2")

1513

(4'

11.

6")

535

(21.

1")

575

(22.

7")

710 (28.0")550 (21.7")

406 (16.0")

227 (8.9")

160 (6.3")

596 (23.5")

min. 1000 (3' 3.4")1

902

(35.

5")

cass

ette

film

pla

ne

fron

t si

de b

ucky

uni

t

120

(4.7

")

Ref. cross point

986 (38.9")

54 (2.1")139 (5.5")

64 (2.5")

107 (4.2")

708 (27.9")

2080

(6'

9.9

")

1990

(6'

6.3

")

max

. 150

0 (4

' 11.

1")

max

. 210

5 (6

' 10.

9")

min

. 300

(11

.8")

min

. 550

(21

.7")

20°

2�

The ceiling suspension CS2 / CS4

for over-table technique consists of:

• Column

• Rail system

• X-ray tube assembly with collimator

and control grip

• Optional: Motor for automatic image

stitching (see room layout on page ��)

Ceiling suspension CS2 / CS4

Column �-part Al telescopic column;adaptable to individual room heights

Weight-balanced vertical movement 1,�80 mm (�8.�") ✓

Format-sensing to control the automatic collimator

Tube support SRO 2��0SRO ��100

Longitudinal travelwith extension rails

�,��0 mm�,0�0 mm

(1�9")(2��")

Transverse movementCS2CS�

1,�7� mm�,19� mm

(�0")(118")

Longitudinal/transverse centering up to 7 lock-in positions can be set

Servo supported longitudinal and tube movement (with automatic image stitching)

Automatic tube alignment for tracking of vertical stand

Tube assembly rotationaround horizontal axisaround vertical axis

±12�º+1��º / –180º

Laser slit light ✓

Ceiling suspension CS

✓ = standard❍ = optional

All dimensions

in mm (feet/inches)

brake rail

max

. cei

ling

heig

ht 3

110

(10'

2.4

") * min

. 125

0 (4

' 1.2

")m

in. 1

235

(4' 0

.6")

(w

ithou

t ß-

stop

)

mov

emen

t ra

nge

0...1

480

(4' 1

0.3"

)m

ovem

ent

rang

e 0.

..149

5 (4

' 10.

9")

(with

out

ß-st

op)

max

. 273

0 (8

' 11.

5")

380

(15"

)

* for max. maneuverability

27

Height adjustable trolley TA-M

Trolley

Height of table adjustment �00 mm to 870 mm (2�.�" to ��.�")

Dimensions with accessories, max. 2,270 mm x 900 mm (7' �.�" x ��.�")

Total weight 1�0 kg (28� lbs)

Brakes At each side

Bariatric table top

Type Floating table top of sandwich design with carbon fiber overlay

Dimension table top (l x w) 2,200 mm x �70 mm (7' 2.�" x 2�.�")

X-ray transparent area 1,7�0 mm x �70 mm (�' 8.1" x 2�.�")

Thickness of table top �� mm (2.1")

Range of horizontal movementstransverselongitudinal

±100 mm (�.�")floating by fixing the vertical axes of the wheels

Attenuation equivalent ≤1.2 mm Al equivalent at 100 kV

Patient load 22� kg (�9� lbs)

28

All dimensions in mm (feet/inches)

Height adjustable trolley TA-M (contd.)

2270 (7' 5.4")

670

(26.

4")

100

(3.9

")10

0(3

.9")

600

(23.

6")

870

(34.

3")

890

(35"

)

54 (

2.1"

)

Image plate reader PCR Eleva S Plus

Image plate reader PCR Eleva S Plus

Type The image plate reader PCR Eleva S Plus consists of• Cassette feeding unit for the cassette• Reader unit

Plate througput Up to 97 plates/h (18 cm x 2� cm) (high-speed mode allowing up to 9� plates/h for �� cm x �� cm)

Cassette release �7 s to �� s, depending on cassette size and type

Cassette feeding unit • Removal of exposed image plate from the cassette• Reading of the image plate (cassette) barcode• Transport of the exposed image plate to and from the

reader unit• Loading the cassette with the erased plate• Release of newly loaded cassette

Reader unitScanning resolution

Read functionErase function

100 µm or 200 µm(200 µm through either software re-sizing or high-speed mode)

12 bit analog/digital conversion of informationExposure-dependent erasure of residual information on the image plate using white light

All dimensions in mm (inches)

29

590 (23.3")

810

(31.

9")

43 (

1.7"

)

380 (15.0")

DRF room solution – Configuration proposals

Configuration 1

EasyDiagnost Eleva with Bucky tray or EasyLat• Ceiling suspended tube carrier (CS2/�)• Digital vertical stand VS with/without tilt

Configuration 2

EasyDiagnost Eleva with digital detector in table• Ceiling suspended tube carrier (CS2/�)

Configuration 3

EasyDiagnost Eleva with digital detector in table• Ceiling suspended tube carrier (CS2/�)• Digital vertical stand VS with/without tilt

�0

Optional available*:

• CR-integration

• Height adjustable trolley TA-M

• Vertical stand VS advanced

with/without tilt

• Tracking

• Automatic image stitching

* Please contact your local sales specialist for additional configurations and accessories

�1

�2

Room planning

Key

1 DI cabinet

2 Image Receiver Module

� Eleva examination control advanced (EEC A)

� Keyboard

� Mouse

� Generator cabinet (Velara)

7 EasyDiagnost Eleva main cabinet

8 DI cabinet rear cover

9 Generator cabinet rear cover

10 Main cabinet rear cover

11 Indication box (IBO)

12 Acquisition work spot

Key (contd.)

1� Infra red receiver

1� ViewForum computer

1� Mouse

1� Keyboard

17 Viewing monitor (18") (maybe combined with moitor for shared mode)

18 Footswitch

19 Monitor carriage

20 Tilting axis

21 Center of table top

22 Speed control

2� Handswitch colon map

2� Exposure handswitch

Key (contd.)

2� Area for service purposes

2� Space required for installing the X-ray module

27 Space required for inserting the table top (alternatively: 2.0� m at the head end in 0° position)

28 If necessary, order an insulating kit for ceiling rails locally

29 For cooling requirements it is absolutely necessary to separate E- and B-cabinet from each other!The minimum space between E- and B-cabinet have to be at least 70 mm! The M-cabinet can positioned side by side to the B-cabinet, the E-cabinet or the wall (see drawing)

Key (contd.)�0 Min. space �–7 mm between

2 Cabinet Rear Cover

�1 EasyDiagnost Eleva

Layout proposal for EasyDiagnost Eleva with under-table technique (single plane)

All dimensions in mm (feet/inches)

Remote serviceEthernet or Telefon connection (Ethernet preferred)

RIS/PACSEthernetconnection

29

1 7 6

30 30

8 910

19

20

18

13

21

11

28 25

31

26

27

cubicle

lavatory

24

23

22

151654

17

1214

3

2

5500 (18' 0.5")

824

(32.

6")

2080

(6'

9.9

")

5200

(17

' 0.7

")

3100 (10' 2.0")2400 (7' 10.5")

1050 (3' 5.3")

1000

(3'

3.4

")

600

(23.

6") 12

00 (

3' 1

1.2"

)

1150 (3' 9.3")

91 (3.6")280 (11.0")

240

(9.5

")

��

Room planning

Layout proposal for EasyDiagnost Eleva with over-table technique (second plane)

Key

1 DI cabinet

2 Image Receiver Module

� Eleva examination control advanced (EEC A)

� Keyboard

� Mouse

� Ceiling rails ceiling suspension

7 Ceiling rails MCS

8 Generator cabinet (Velara)

9 EasyDiagnost Eleva main cabinet

10 DI cabinet rear cover

11 Monitor ceiling suspension

Key (contd.)

12 Generator cabinet rear cover

1� Main cabinet rear cover

1� Acquisition work spot

1� Indication box (IBO)

1� BuckyDiagnost VS advanced tilt

17 Infra red receiver

18 Examination monitor (18")

19 Reference monitor (18")

20 ViewForum computer

21 Mouse

22 Keyboard

Key (contd.)

2� Viewing monitor (18") (maybe combined with monitor for shared mode)

2� Speed control

2� Handswitch colom map

2� Exposure handswitch

27 Footswitch

28 Ref. cross point

29 If necessary, order an insulating kit for ceiling rails locally

�0 Important!In case the CS rail runs above the EasyDiagnost image intensifier, enlarge the minimum ceiling height by 1�0 mm to prevent collision

Key (contd.)

�1 SID max. 1800 mm with table in upright position

�2 For cooling requirements it is absolutely necessary to separate E- and B-cabinet from each other!The minimum space between E- and B-cabinet have to be at least 70 mm! The M-cabinet can positioned side by side to the B-cabinet, the E-cabinet or the wall (see drawing)

�� Min. space �–7 mm between 2 Cabinet Rear Cover

�� Tube in position “free exposure”

�� EasyDiagnost Eleva

�� Depend on room size

All dimensions in mm (feet/inches)

Remote serviceEthernet or Telefon connection (Ethernet preferred)

RIS/PACSEthernetconnection

cubicle

lavatory

26

25

24

212254

23

1420

3

2

15

33

1

13

12

32

33

8

9

10

17

19

18

117

29

34

27

30

1628

31

35

6

36

5800

(19

' 0.3

")

1515

(4'

11.

6")

1500

(4'

11.

1")

≥ 6665 (21' 10.4")

≥ 3525 (11' 6.8") 3140 (10' 3.6")

835 (32.9")986 (38.8") 835 (32.9")

2200 (7' 2.6") ext. rails, max. 2700 (8' 10.3")

1000 (3' 3.4") 1000 (3' 3.4")

SID max. 1800 (5' 10.9")

80 (3.2")

4300 (14' 1.3")

479

(18.

9")

��

Key

1 DI cabinet

2 Image Receiver Module

� Eleva examination control advanced (EEC A)

� Keyboard

� Mouse

� Ceiling rails ceiling suspension

7 Ceiling rails MCS

8 CS

9 Generator cabinet (Velara)

10 EasyDiagnost Eleva main cabinet

11 DI cabinet rear cover

Room planning

Layout proposal for DRF room solution with digital vertical stand (minimum room layout without applicational restrictions)

Key (contd.)

12 Monitor ceiling suspension

1� Generator cabinet rear cover

1� Main cabinet rear cover

1� ViewForum computer

1� Indication box (IBO)

17 Acquisition work spot

18 BuckyDiagnost VS digital with motorized tilting

19 Infra red receiver

20 Examination monitor (18")

21 Reference monitor (18")

22 Mouse

2� Keyboard

Key (contd.)2� Viewing monitor (18")

(maybe combined with monitor for shared mode)

2� Footswitch

2� Speed control

27 Handswitch colon map

28 Exposure handswitch

29 If necessary, order an insulating kit for ceiling rails locally

�0 Important!In case the CS rail runs above the EasyDiagnost image intensifier, enlarge the minimum ceiling height by 1�0 mm to prevent collision

�1 External rails (optional)

Key (contd.)

�2 Scopomat in work position

�� For cooling requirements it is absolutely necessary to separate E- and B-cabinet from each other!The minimum space between E- and B-cabinet have to be at least 70 mm! The M-cabinet can positioned side by side to the B-cabinet, the E-cabinet or the wall (see drawing)

�� Min. space �–7 mm between 2 Cabinet Rear Cover

�� EasyDiagnost Eleva

�� Only with option stitching

All dimensions in mm (feet/inches)

Remote serviceEthernet or Telefon connection (Ethernet preferred)

RIS/PACSEthernetconnection

33

1 10 9

34 34

11 1314

28

27

26

222354

24

1715

3

2

29

16

19

21

20

7

31

32

1825

8

30

6

cubicle

lavatory

12

35

≥ 6100 (20' 0.2")

5800

(19

' 0.3

")

≥ 3430 (11' 3.0") 2670 (8' 9.1")

SID 1800 (5' 10.9")SID min. 1000 (3' 3.4")

835 (32.9")1000 (3' 3.4")1000 (3' 3.4")835 (32.9")

986 (38.8")

1580

(5'

2.2

")

1500

(4'

11.

1")

1075

(3'

6.3

")

1150

(3'

9.3

")

3636

��

General

Power supply Verticalstand VS

Eleva workspot EasyDiagnost Eleva Generator 50 kW

Mains voltage 2�0 V ±10% 11� V to 2�0 V +10%; -1�%

2�0 V ±10% �00 V ±10%; � phase

Mains frequency �0 Hz / �0 Hz �0 Hz / �0 Hz �0 Hz / �0 Hz �0 Hz / �0 Hz

Current input max. 1.7 A max. 2.� A max. 7.� A max. 1�� A

Fuse �A 10 A 10 A � x �� A

Heat dissipation (average)

100 W 1�0 W �00 W - max. 1�00 W �00 W

Ambient conditions

Working temperature +18˚C to +�0˚C

Storage temperature –10˚C to +��˚C

Rel. humidity (in operation) 20% to 7�% (without condensation)

Rel. humidity (storage) 10% to 9�%

Air pressure 700 hPa to 10�0 hPA

Conformity

The EasyDiagnost Eleva system and the related room solutions comply with the provisions of the Medical Device Direktive 9�/�2 EEC (9�) and with IEC, FDA and CSA standards.

Philips Healthcare is part of

Royal Philips Electronics

How to reach us

www.philips.com/healthcare

[email protected]

fax: +�1 �0 27 �� 887

Asia

+8�2 2821 �888

Europe, Middle East, Africa

+�9 70�1 ��� 22��

Latin America

+�� 11 212� 07��

North America

+ 1 �2� �87 7000

800 28� ��8� (toll free, US only)

Philips Healthcare

Global Information Center

P.O. Box 128�

��02 BG Eindhoven

The Netherlands

© 2009 Koninklijke Philips Electronics N.V.All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.

Printed in The Netherlands.��22 9�2 �0��1/70� * APR 2009