rri #20127 dublin, oh proposed plus...
TRANSCRIPT
480 Milford Parkway • Milford, OH 45150phone 513-576-8090 • fax 513-576-8095
Drawing by: RP Checked by: BD
2005 Triumph Signs & Consulting, Inc. / All rights reserved.
This drawing was created by Triumph Signs & Consulting,
Inc., and contains exclusive design elements by Triumph and
may not be reproduced or utilized without consent from
Triumph.
Please read carefully and check appropriate box:
Sketch OK as is Sketch OK with
New sketch required
Date Signature
changes
Sketch No. RRI 20127 Dublin
Scale: Proportional
Date: 3/5/14 Revised: 5/20/14
Locations:Red Roof Inn #20127Dublin, OH
RRI #20127 Dublin, OH PROPOSED PLUS LOCATIONS
Front of Building Rear of Building
Entrance Sign
NEW ENTRANCE SIGNWITH PLUS LOGO
CHANNEL LETTERSADD PLUS LOGO
CHANNEL LETTERSADD PLUS LOGO
480 Milford Parkway • Milford, OH 45150phone 513-576-8090 • fax 513-576-8095
Drawing by: RP Checked by: BD
2005 Triumph Signs & Consulting, Inc. / All rights reserved.
This drawing was created by Triumph Signs & Consulting,
Inc., and contains exclusive design elements by Triumph and
may not be reproduced or utilized without consent from
Triumph.
Please read carefully and check appropriate box:
Sketch OK as is Sketch OK with
New sketch required
Date Signature
changes
Specifications:
• Face lit LED illuminated channel letters
• UL approved with cut off switch.
• “Red Roof” Letters: Red LED’s
• Red Acrylic: #2793 Red
• “Plus +” Letters: Yellow LED’s
• Yellow Acrylic: #2016 Yellow
6‘ 5-1/2”
”4/1-9138
-1/2
”41
-1/2
”6’ 9-1/4”
73.66 Sq. Ft.
”2/1-01 ’01
31-3/4”
Sketch No. RRI 20127 Dublin
Scale: Proportional
Date: 3/11/14 Revised: 5/20/14
Locations:
Red Roof Inn #20127Dublin, OH
3/16” Acrylic Face
LED Illumination
8”Sloan Power Supply (120v/24vdc)
TYPICAL SECTION DETAIL - FACE LIT INTERNALLY ILLUMINATED LETTERS
Sloan supply wiring from power
8” x .040 WriscoPre-Painted BlackAluminum Returns1” Black Jewelite
Existing
Proposed
RRI #20127 Dublin, OHFront of Building
New “Plus +”Letters
10’ 10½”
6’ 5½”
Remove “inn”Letters Only
19’ 6”
10’ 6”
Grade to Topof Letters
Leave ExistingRed Roof andHockey Stick
6’ 5½”
70.25 Sq. Ft.
480 Milford Parkway • Milford, OH 45150phone 513-576-8090 • fax 513-576-8095
Drawing by: RP Checked by: BD
2005 Triumph Signs & Consulting, Inc. / All rights reserved.
This drawing was created by Triumph Signs & Consulting,
Inc., and contains exclusive design elements by Triumph and
may not be reproduced or utilized without consent from
Triumph.
Please read carefully and check appropriate box:
Sketch OK as is Sketch OK with
New sketch required
Date Signature
changes
Existing
Specifications:
• Face lit LED illuminated channel letters
• UL approved with cut off switch.
• “Red Roof” Letters: Red LED’s
• Red Acrylic: #2793 Red
• “Plus +” Letters: Yellow LED’s
• Yellow Acrylic: #2016 Yellow
6‘ 5-1/2”
”4/1-9138
-1/2
”41
-1/2
”6’ 9-1/4”
73.66 Sq. Ft.70.25 Sq. Ft.
”2/1-01 ’01
31-3/4”
Proposed
Sketch No. RRI 20127 Dublin
Scale: Proportional
Date: 3/11/14 Revised: 5/20/14
Locations:
Red Roof Inn #20127
RRI #20127 Dublin, OH
Dublin, OH
3/16” Acrylic Face
LED Illumination
8”Sloan Power Supply (120v/24vdc)
TYPICAL SECTION DETAIL - FACE LIT INTERNALLY ILLUMINATED LETTERS
Sloan supply wiring from power
8” x .040 WriscoPre-Painted BlackAluminum Returns1” Black Jewelite
Remove “inn”Letters Only
20’ 6”
10’ 6”
Grade to Topof Letters
Leave ExistingRed Roof andHockey Stick
New “Plus +”Letters
6’ 5½”
10’ 10½”
6’ 5½”
Rear of Building