s80 laser distance sensors. s80 highlights 2 models with measurement ranges up to 4000mm and 7000mm...
TRANSCRIPT
S80 Laser Distance Sensors
S80 Highlights2 models with measurement ranges up to 4000mm and 7000mm
Retro-reflective models up to 20m and 100m
2 NPN or PNP switching outputs and a 4 – 20mA analog output
RS485 serial interface for complete remote control and for measurement transmission with 12-bit resolution
IP67 metallic compact housing and a standard M12 8-pole connection
Scalable range for the long distance model (7000mm)
Distance Sensor TechnologyOptical triangulation Time-of-flight measurement
1. Near distances (<1m)
2. Limited range
3. Resolution variable with the distance up to µm
1. Medium and far distances (1~100m)
2. Wide range
3. Constant resolution throughout the entire range
Time of Flight Technology
Based upon the principle of radar:
1. A laser diode emits short but strong pulses with a pause of several µs.
2. The pulses reach the target, come back, and are received by an avalanche photodiode (APD), through a separate optic.
Time-of-Flight Technology
Distance:D = (TOF)0.5C
D = distanceTOF = time of flightC = light speedin the medium involved
The time-of-flight (TOF) difference between the transmission and the reception of the same pulse is directly measured and converted into a distance value.
Emitted signal
Received signal
S80 Family
S80-Y0
S80-YL09
Proximity TOF laser sensor0.3-4m Distance rangeDigital Resolution 12-bit = 0.9mm
0.3-7m Extended scalable rangeDigital Resolution 14-bit = 0.5mm2-set point background suppression
Wenglor XT200MGVSick DL60SensoPart FR91-ILA
Banner LT3Wenglor YT89Balluff BOD 63-MSick DS60
S80-Y1
S80-Y2
Retro-reflective TOF laser sensor0.3-20.3m Operating distanceDigital Resolution 15-bit = 0.6mm
Retro-reflective TOF laser sensor0.3-100.3m Operating distanceDigital Resolution 14-bit = 6mm
Wenglor XT101PXVBanner LT7(SensoPart FR9-ILA)
S80L-Y Specifications S80-MH-5-Y09-PPIZMeasuring range 300 – 4000mmDigital Resolution 0.6mmLinearity < 0.3% Temperature drift < 0.6mm/°CLight Source Red laser class 2Time of response 5ms (NORM); 1ms (FAST)Channel/Out 2 PNP or NPN; 4 – 20mA
analogSetting 3 push-buttonsIndicators 4-digit display + 5 LEDsHousing ABS aluminium IP67Dimensions 34 x 73 x 90 (mm) Connection M12 8-pole rotating
connectorOther features Synchronization
RS485 interfaceDelay
0.3 2 3.5 7
6
18
36
54
72
90 White
Black
Gray-scale
d [m]
Reflection [%]
The distance range measured (but not the precision) slightly depends on the reflection degree of the target.
Degree of Reflection Influence
Measurement range
Control Panel
‘OR’ of the 2-channeloperation LED
Output status LEDs
Response time LED
4-digit display for measurementvisualization (in mm) and setting
Setting and Menu access push-button
Menu skipping and parameter adjustment
push-buttons
Connections
The wire color is compliant to European standards.
Mounting There are many possible mounting positions when
using the ST-5037 bracket.
S80L-Y vs Banner LT3
LT3
Measuring range 300 – 5000mmResolution 1mmLinearity max 30mm Temperature drift < 2mm/°CLight Source Red laser class 2Response time 1ms; 10ms; 100msChannel/Output 1 PNP or NPN
4–20mA or 0–10V analogSetting 3 push-buttonsIndicators 8 LEDsHousing ABS polycarbonate IP67Dimensions 35 x 69 x 87 (mm) Connection M12 7-pole rotating connector
S80L-Y vs Balluff BOD 63-M
BOD 63-M
Measuring range 500 – 6000mmResolution 5mmLinearity 1% Temperature drift NALight Source Red laser class 2Response time 5msChannel/Output 1 PNP or NPN
4–20mA or 0–10V analogSetting 1 switchIndicators 3 LEDsHousing Anodized aluminumDimensions 35 x 70 x 90 (mm) Connection M12 8-pole rotating connector
S80L-Y vs Wenglor YT-89 YT89PXVT80
Measuring range 400 – 4000mmResolution 8mmLinearity 1% Temperature drift < 1mm/°CLight Source Red laser class 2Response time 5 msChannel/Out 2 PNP or NPN ; 0 – 10V
analogSetting 1 rotating selector
1 push-buttonIndicators 3 LEDsHousing ABS plastic IP67Dimensions 36 x 75 x 81 (mm) Connection M12 8-pole rotating
connectorSerial interface RS232
S80L-Y vs Sick DS 60
DS 60
Measuring range 200 – 6000mmTemperature drift not givenLight Source InfraredResponse time NAChannel/Out 2 PNP or NPNSetting 1 push-buttonIndicators 2 LEDsHousing IP67Dimensions 38x 104 x 87 Connection M12 5-poles
Application Notes(1)
Distance measurement of a moving pallet
Application Notes (2)
Position and diameter check of rolled materials
Application Notes(3)
Material level control in a hopper
Application Notes(4)
Measurement of the distance between a forklift and pallet
Application Notes(5)
Correct length detection of wood with or without bark