Experience Is Not Enough
![Page 3: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/3.jpg)
Scaffold Accident Statistics
22% of all worker fall accidents were from scaffolds
2008 2009 2010
So
All Worker Falls
2008
2009
2010
100%
80%
60%
40%
20%
0
ScaffoldOther
![Page 4: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/4.jpg)
Local Law 52 of 2005
In 2005, the City Council passed Local Law 52 of 2005 requiring:
•
Permits be obtained for supported scaffolds 40 feet or greater in height
•
All supported scaffold users & erectors have proper training
![Page 5: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/5.jpg)
Local Law 17 of 2007
In 2007, the City Council passed Local Law 17 of 2007 requiring:
•
Department notification by riggers of all installations of c‐hook and outrigger beams
supporting suspended scaffolds
![Page 6: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/6.jpg)
Scaffold Safety Unit
•
Formed in 2007
•
Inspects supported and suspended scaffolds and sidewalk sheds
•
Performs industry outreach
•
Approves scaffold training courses and audits providers
•
Performed more than 8,300 inspections in 2010
![Page 7: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/7.jpg)
2010 Scaffold Statistics
•12,621
suspended scaffold notifications
•8,577 c‐hook notifications
•4,044 outrigger beam notifications
•2,678 supported scaffold permits issued
•5,844
sidewalk shed permits issued
•3,809
complaints received about sidewalk sheds and scaffolds
![Page 8: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/8.jpg)
Administrative Violations
Common violations issued for failing to provide:
•
License rigger
•
Designated foreman on site
•
Daily logs kept
•
Permit(s)
•
Notification(s)
•
Training cards
•
“Certificates of Fitness“
•
Design drawings
![Page 9: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/9.jpg)
Sidewalk Shed Violations
Common violations issued for sidewalk sheds:
•
No lights / defective lighting
•
Defective mud sill
•
Out of plumb vertical members
•
Loose / missing cross braces
•
Deck enclosure loose
•
Deck not extended past side lot line
•
Advertisement on parapet
![Page 10: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/10.jpg)
Sidewalk Shed Violations
No Lights /Defective Lighting
UnderSidewalk Shed
Decking
![Page 11: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/11.jpg)
Sidewalk Shed Violations
Defective Mud Sill
![Page 12: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/12.jpg)
Sidewalk Shed Violations
Out ofPlumbVerticalMembers
![Page 13: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/13.jpg)
Sidewalk Shed Violations
Loose / Missing Braces
![Page 14: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/14.jpg)
Sidewalk Shed Violations
Deck Enclosure Missing
![Page 15: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/15.jpg)
Sidewalk Shed Violations
Protection Not Extended Past Side Lot Line
![Page 16: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/16.jpg)
Sidewalk Shed Violations
Advertisement on Parapet
![Page 17: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/17.jpg)
Suspended Scaffold Violations
Common technical violations with suspended scaffoldings:
•
No harness / life line
•
Improper C‐Hook tieback
•
Defective wire rope / birdcage
•
Defective wire rope splice / termination
•
Inappropriate counterweight
•
Defective / inappropriate outrigger beam
•
No life line padding
•
Defective support / parapet
![Page 18: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/18.jpg)
Suspended Scaffold Violations
No Harness or Life Line
![Page 19: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/19.jpg)
Suspended Scaffold Violations
Improper C‐Hook Tieback
![Page 20: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/20.jpg)
Suspended Scaffold Violations
Defective Wire Rope / Birdcage
![Page 21: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/21.jpg)
Suspended Scaffold Violations
Defective Wire Rope Splice / Termination
![Page 22: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/22.jpg)
Suspended Scaffold Violations
Inappropriate Counterweight
![Page 23: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/23.jpg)
Suspended Scaffold Violations
Defective / Inappropriate Outrigger Beam
![Page 24: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/24.jpg)
Suspended Scaffold Violations
No Life Line Padding
![Page 25: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/25.jpg)
Common Violations
Defective Support / Parapet
![Page 26: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/26.jpg)
Supported Scaffold Violations
Common technical violations issued for supportedscaffoldings:
•
Improper support for work deck
•
Excessive planking / overhang
•
Scaffold screw adjustment improper
•
Inadequate tieback
•
Improper / missing guardrails
•
Improper access
•
Defective / missing debris netting
![Page 27: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/27.jpg)
Improper Work Deck Support
Supported Scaffold Violations
![Page 28: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/28.jpg)
Supported Scaffold Violations
Excessive Planking Overhang
![Page 29: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/29.jpg)
Supported Scaffold Violations
Scaffold Screw Adjustment Improper
![Page 30: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/30.jpg)
Supported Scaffold Violations
Foundation / Improper
![Page 31: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/31.jpg)
Supported Scaffold Violations
Foundation / Improper
![Page 32: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/32.jpg)
Supported Scaffold Violations
Inadequate Tieback
![Page 33: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/33.jpg)
Supported Scaffold Violations
Improper /Missing
Guardrails
![Page 34: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/34.jpg)
Supported Scaffold Violations
Improper Access
Improper Access
![Page 35: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/35.jpg)
Supported Scaffold Violations
Defective / Missing Debris Netting
![Page 36: Safe Scaffold Operations - City of New York · 2011. Safe Scaffold Operations. Robert D’Alessio. April 25, 2011 –NY. U Rosenthal Pavilion. build safe | live safe](https://reader031.vdocument.in/reader031/viewer/2022022514/5af7cc507f8b9ae948909d36/html5/thumbnails/36.jpg)
NYC Construction Code References
•
Chapter 33, Section 3314 of the New York City Building Code
(Scaffold section)
•
1 RCNY 9 (Rule 9)
•
Title 28, Article 404 (Licensing of riggers)
•
Title 28, Chapter 1 (Permits, etc)
•
OSHA Subpart L 1926.451;1926.452 (scaffolds)
•
OSHA 1926.501 and 1926.502 (personal fall protection)
•
www.nyc.gov/buildings