safety products l a t ca s uct rod p y fet a s 2013safety+catalogue+2013.pdf · 2015. 10. 29. ·...

20
SAFETY PRODUCTS CATALOGUE SAFETY PRODUCTS Passionately Helping Customers Be More Successful 2013

Upload: others

Post on 09-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

SA

FE

TY

P

RO

DU

CT

S C

AT

ALO

GU

E

SAFETY PRODUCTS

Passionately Helping Customers

Be More Successful 2013

Page 2: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

SSAAFFEETTYY PPRROODDUUCCTTSS CCAATTAALLOOGGUUEE

TTAABBLLEE OOFF CCOONNTTEENNTTSS

How Does A Vital Dynamic Circuit Work..………………………………………………………………………...………………….1

Compliance To Standards Referenced By Safety Engineers……………………………………….......................………...…...2

Safety Controller Vital & Tina Units …………………………………..………………………………………………………………3

Programmable Safety Controllers ………………………………………………………….……………...........………………..….3

Safety Relays……..……………………………………………………………………………......................…………………….....4

Eden Non – Contact and Non – Magnetic Safety Sensor For Highest Level of Safety………..….....................…….………..5

Emergency Stops ………………….……………………………………………………………......................……………………...6

Optical Safety Devices ………………………………………………………………………......................………………………...7

Bjorn Stand System For Light Grids & Mirrors…….………………………………………......................……………………..….8

Control Devices…………………………………………………………………………………......................…………………...….9

Accessories, Connectors & Cables…….……………………………………………………......................………………………10

Mkey Tongue Operated Safety Interlock Switch…………………………………………………………………………………...11

Coded Non – Contact Safety Switches…………………………………………………………………………………………...…12

E – Strong Z Heavy Duty Emergency Stop Switches…………………………………………………………………………..….13

Line Strong Series – Grab Wire Safety Rope Switches…………………………………………………………………………...14

Edge 1 safety limit switches……………………………………………………………………………………………………….….15

Page 3: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

HHOOWW DDOOEESS AA VVIITTAALL DDYYNNAAMMIICC CCIIRRCCUUIITT WWOORRKK??

For additional information on the products and delivery, contact your local branch.

Page 1

Dynamic signal consists of a square wave that is transmitted through the safety circuit

Dynamic signal is transmitted throughout all the protection devices

If a protection device breaks/opens, the dynamic signal is not transmitted

Vital controller detects missing signal and open its safe outputs

WWHHYY SSHHOOUULLDD YYOOUU UUSSEE TTHHEE VVIITTAALL SSAAFFEETTYY SSYYSSTTEEMM??

Vital is the heart of a solution which makes it possible to install/connect many different types of safety devices in the same safety circuit at category 4 to supervise safety components.

Up to 30 dynamic sensors can be connected

directly in the safety circuit

Connection can be made by using standard or

M12 equipped cable.

PL e, according to EN ISO 13849-1 dynamic

safety circuit

Can accommodate long cable lengths

Manually supervised or automatic reset

Safety components with output contacts can be

connected to the Vital via low cost Tina adapters

Detachable connector blocks

LED indication of power supply, dynamic signal

and outputs

Information output with two functions

Cost-effective cable routing/connections

Two NO safety outputs

Page 4: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 2

SIL PFHd

3 >_ 10-8 to >10-7

2 >_ 10-7 to >10-6

1 >_ 10-6 to >10-5

CCOOMMPPLLIIAANNCCEE TTOO SSTTAANNDDAARRDDSS RREEFFEERREENNCCEEDD BBYY SSAAFFEETTYY EENNGGIINNEEEERRSS

If you choose to design a safety function in accordance with EN 62061, the level of reliability is expressed as the Safety Integrity Level—SIL. There are a total of 4 levels, but in the EN 62061 standard SIL 3 is the highest level. SIL, similar to the Performance Level (PL), is also expressed as the Probability of Dangerous Failure per Hour—PFHd.

Method in EN 62061 for Assigning the Safety Integrity Level (SIL)

Severity (Se) Class (Cl) 3-4 5-7 8-10 11-13 14-15

4 SIL2 SIL2 SIL2 SIL3 SIL3

3 (OM) SIL1 SIL2 SIL3

2 (OM) SIL1 SIL2

1 (OM) SIL1

CCAANNAADDIIAANN SSTTAANNDDAARRDDSS::

Standard Number Type

CSA Z142 Code for Power Press Operation: Health, Safety and Guarding Requirements

CSA 434 Safeguarding of Robots

CSA 432 General Machine Safeguarding

CCOONNTTRROOLL RREELLIIAABBIILLIITTYY

Control reliable safety control system shall be dual channel with monitoring. Such systems shall be designed, constructed, and applied such that any single component failure (including monitoring) shall not prevent the stopping action of the equipment. The safety control system shall be hardware based or comply with Clause 8.3 and include automatic monitoring at the system level conforming to the following:

a) The monitoring shall generate a stop if a fault is detected. A warning shall be provided if a failure hazard remain

after cessation of motion.

b) Following detection of a fault, a safe state shall be maintained until the fault is cleared.

c) Common mode failures shall be taken into account when the probability of such a failure occurring is significant.

d) The single fault should be detected at time of failure. If not practicable, the failure shall be detected at the next

demand upon the safety function.

e) The safety control system shall be independent of the normal program control (function) and shall be designed to

be not easily defeated nor easily bypassed without detection.

Page 5: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 3

SSAAFFEETTYY CCOONNTTRROOLLLLEERR VVIITTAALL AANNDD TTIINNAA UUNNIITTSS

IMAGES DESIGNATION ARTICLE NUMBER DESCRIPTION

Vital

Vital 1

2TLA020052R1000

Safety module with one single channel input for dynamic sensors. Relay outputs 2NO.

Tina

Tina 1A

2TLA020054R0000

Tina 1A is a device that is designed for use with the connection block Tina 4A or 8A, where it is used as a blind plug in unused M12 connection.

Tina 2A

2TLA020054R0100

Adaption unit for dynamic circuits. Tina 2A is with M20 fitting for connection of emergency stops and other safety devices having a suitable combination of potential free contacts.

Tina 3A

2TLA020054R0200

Adaption unit for dynamic circuits. Tina 3A with M12 connection and M20 fitting for use with emergency stop and other safety sensors with potential free contacts.

Tina 10A

2TLA020054R1200 Adaption unit were OSSD outputs (PNP) from Focus II can be Transformed for dynamic circuits.

Tina 4A

2TLA020054R0300

Connection block with adaption unit for dynamic circuits. Four M12 5-pole connectors for sensor input. Each sensors information status can be wired separately. Cable connection diameter range: 7-12mm.

Tina 8A

2TLA020054R0500

Connection block with adaption unit for dynamic circuits. Eight M12 5-pole connectors for sensor input. Each sensors information status can be wired separately. Cable connection diameter range: 7-12 mm.

PPRROOGGRRAAMMMMAABBLLEE SSAAFFEETTYY CCOONNTTRROOLLLLEERRSS

IMAGES DESIGNATION ARTICLE NUMBER DESCRIPTION

Pluto S20

2TLA020070R0500

Safety PLC. Totally 20 I/O: 8 failsafe inputs + 8 non-failsafe outputs/failsafe inputs + 2 individually failsafe relay outputs + 2 individually failsafe transistor outputs. (No Pluto safety bus).

Pluto B20

2TLA020070R0600

Safety PLC with Pluto safety bus. Totally 20 I/O: 8 failsafe inputs + 8 non-failsafe outputs/failsafe inputs + 2 individually failsafe relay outputs + 2 individually failsafe transistor outputs.

Pluto B16

2TLA020070R0700 Safety PLC Pluto safety bus. Totally 16 I/O: 8 failsafe inputs + 8 non-failsafe outputs/failsafe inputs. (No Pluto safety outputs).

Pluto B46 v2

2TLA020070R1700

Safety PLC with Pluto safety bus. Totally 46 I/O: 24 failsafe inputs + 16 non-failsafe outputs/failsafe inputs + 4 individually failsafe relay outputs + 2 individually failsafe transistor outputs.

Pluto S46 v2

2TLA020070R1800

Safety PLC. Totally 46 I/O: 24 failsafe inputs + 16 non-failsafe outputs/failsafe inputs + 4 individually failsafe relay outputs + 2 individually failsafe transistor outputs. (No Pluto safety bus).

Accessories for Programmable Safety Controllers

IDFIX-R

2TLA020070R2000 Identifier, read only. For assigning Pluto an address on the Pluto bus. The IDFIX number is fixed by delivery.

IDFIX-PROG 2k5

2TLA020070R2400

External program memory, 2.5 Kbyte. For projects with only one Pluto the memory can store the PLC program. Can also be used to give Pluto AS-I a specific address.

Pluto programming

cable USB

2TLA020070R5800

For connecting PC, USB port to Pluto for programming and on- line monitoring.

Page 6: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch. Page 4

SSAAFFEETTYY RREELLAAYYS

IMAGES DESIGNATION ARTICLE NUMBER DESCRIPTION

Safety Relay – RT – Series

RT6 24DC Safety relay

2TLA010026R0000

A universal safety relay for several safety applications. Relay outputs 3NO/1NC.

RT7A 1.5s 24DC Safety

relay

2TLA010028R2000

A universal safety relay for several safety applications. 2 delayed outputs of 1.5 sec. Relay outputs 2NO/2NO/1NC.

RT7B 3s 24DC Safety relay

2TLA010028R1000

A universal safety relay for several safety applications. 2 delayed outputs of 3 sec. Relay outputs 2NO/2NO/1NC.

RT9 24DC Safety relay

2TLA010029R0000

A universal safety relay for several safety applications. Relay outputs 2NO.

Safety Relay – JSB - Series

JSBR4 24DC Safety relay

2TLA010002R0000

Safety relay for two hand device and many other safety products. Power supply 24VDC. Relay outputs 3NO/1NC.

Expansion Relays

E1T 0s 24DC Expansion relay

2TLA010030R0000

Safety expansion relay - for expanding the outputs of safety relays. Time delay 0 sec. Relay outputs 4NO.

E1T 1s 24DC

Expansion relay

2TLA010030R2000

Safety expansion relay - for expanding the outputs of safety relays. Time delay 1 sec. Relay outputs 4NO.

E1T 2s 24DC

Expansion relay

2TLA010030R4000

Safety expansion relay - for expanding the outputs of safety relays. Time delay 2 sec. Relay outputs 4NO.

JSR3T

24AC/DC Expansion relay

2TLA010017R0100

Safety expansion relay for safe delayed outputs. Hardwire Selectable Delay 0.5 - 10.0 sec. Relay Outputs 1NO+1NO.

Page 7: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 5

EEDDEENN NNOONN –– CCOONNTTAACCTT AANNDD NNOONN –– MMAAGGNNEETTIICC SSAAFFEETTYY SSEENNSSOORR FFOORR HHIIGGHHEESSTT LLEEVVEELL OOFF

SSAAFFEETTYY Eden - Adam and Eva - is a non-contact safety sensor for use on interlocked gates, hatches, etc.

Safety category 4 according to EN 954-1/EN ISO 13849-1 together with Vital or

Pluto.

Up to 30 sensors connected in series at safety category 4

Versatile mounting, 3600 detection

Protection class IP67 (Eden E - IP69K)

Signal will penetrate through non-metallic materials (wood, plastic, etc.)

Safety light beams, E-stops and Eden can be connected in the same safety

circuit together with Vital or Pluto meeting safety PLe (Performance level)

according to EN ISO 13849-1

LED indication on sensor and status information via the connector cable

Small hysteresis (< 1mm)

Flexible Mounting

The ability to operate at distances of up to 15mm and at different detection directions allows a wide range of mounting possibilities.

Applications:

■ Doors and Hatches ■ Position Control

■ Sector Detection ■ Slot Detection

SSEENNSSOORRSS,, SSWWIITTCCHHEESS AANNDD LLOOCCKKSS

IMAGES DESIGNATION ARTICLE NUMBER DESCRIPTION

Eden – Non – Contact Safety Sensor

Eva

2TLA020046R0000

Eva actuator for use with Adam sensors in the Eden sensor system, IP67, yellow, 4pcs of DA2 spacer rings are included.

Eva E

2TLA020046R0600

Eva actuator for use with Adam sensors, encapsulated in polyurethane for harsh environments, IP69K, yellow

Adam with M12

contact

2TLA020051R0000

Adam safety sensor unit with a fixed M12 male connector, IP67, yellow, 4pcs of DA1 protection plate and 4pcs of DA2 spacer rings are included.

Adam 10 m cable with M12

2TLA020051R0400

Adam safety sensor unit with 10 m of cable (5 × 0.34 mm2 + screen) and M12, IP67, yellow, 4pcs of DA1 protection plate and 4pcs of DA2 spacer rings are included

Adam E 10 m

cable with M12

2TLA020051R0600

Adam safety sensor unit, encapsulated in polyurethane for harsh environments with 10 m of cable (5 × 0.34 mm2 + screen) and M12, IP69K, yellow.

Page 8: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 6

Magne – Magnetic Process Lock

Magne 1A

2TLA042022R0000 Electro-magnet with 5-pole M12-contact. Anchor plate. Cell rubber.

Magne 2A

2TLA042022R1000

Magnetic lock with safety sensor. Electro-magnet with 8- pole M12‑contact. Anchor plate. Cell rubber. Adam

(built-in) + Eva (free) door position sensor.

EEMMEERRGGEENNCCYY SSTTOOPPSS

IMAGES DESIGNATION ARTICLE NUMBER DESCRIPTION

INCA

INCA 1 Tina

2TLA030054R0000

Emergency stop button for panel mounting, 22.5 mm holes, Tina adaption unit included for dynamic circuit, Status LED in button, terminal blocks.

SMILE

Smile 11 EA

Tina

2TLA030050R0000

Emergency stop in Smile enclosure, Tina adaption unit included for dynamic circuit, Status LED in button, 1 × M12 5-pin male connector.

Accessories for Emergency Stops and Pilot Devices

Yellow surround

for Inca

2TLA030054R0400

Elevated yellow surround for panel mounted emergency stop button.

Emergency Stop Sign

2TLA030054R0600

Yellow surround for panel mounted emergency stop button, for 22.5 mm hole, with text in English, French and German.

Page 9: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 7

OOPPTTIICCAALL SSAAFFEETTYY DDEEVVIICCEESS

Optical protection in an opening or around a risk area for:

Automated Machinery

Robotic cells

Conveyors

Material Handling Equipment

Printing Presses

Welding Equipment

Machining Centers

Packaging Machinery

Features:

Type 4 according to EN 61496

Flexible assembly

LED indication

High protection class (IP65)

Range 3 to 40 m

Time reset

Floating /Fixed Blanking

Muting

Single/Double break function (PSDI)

External Device Monitoring (EDM)

Available with different resolutions

Up to PL e according to EN 954-1/EN

ISO 13849-1

APPROVALS

OOPPTTIICCAALL SSAAFFEETTYY DDEEVVIICCEESS

IMAGES DESIGNATION DESCRIPTION

Light Curtains Focus || - 14mm Beam Spacing – 150 to 2400mm Height Options

FII-4-14-xxx

Focus II Light Curtain Transmitter + Receiver, 14 mm resolution, range 0.2-6 m, Type 4.

30mm Beam Spacing - 150 to 2400mm Height Options

FII-4-30-xxx

Focus II Light Curtain Transmitter + Receiver, 30 mm resolution, range 0.2-14 m, Type 4.

Note: Additional Light Grids with 500-1200mm long 2-4 Beams are available upon request. Spot

IMAGES DESIGNATION ARTICLE NUMBER DESCRIPTION

Spot 10 T/R

2TLA020009R0600

Safety light beam for up to 10 m distance. M18 steel casing with M12 connector.

Accessories for Optical Safety Devices

MUTE R (FSTR1)

2TLA022044R0000

Mute R (FSTR 1) Retro-reflecting photo-cell M18/M12. Range with FZR1: 0.15-2.5 m. FZR2A: 0.15-5.1 m.

JSM64 Bracket with angle

possibility for M18

2TLA040007R0200 Adjustable mounting bracket with rotational knuckle for 18 mm barrel style sensors. Example, Spot 10T/R or MUTE R (FSTR1).

Page 10: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 8

BBJJOORRNN SSTTAANNDD SSYYSSTTEEMM FFOORR LLIIGGHHTT GGRRIIDDSS AANNDD MMIIRRRROORRSS

Bjorn is a very stable and flexible stand system in which Focus II Safety Light Beams and Mirrors are mounted in the stand. The hardware for the mirrors in the stand can be turned to provide either vertical or horizontal angles. The robust material of the Bjorn protects Focus units from direct collisions, thus preventing unnecessary material damage and halts in production.

BBJJOORRNN TTEECCHHNNIICCAALL DDAATTAA

Applications

■ Protects mirrors and Light Beams Features ■ Robust ■ Adjustable

Manufacturer ABB/Jokab Safety, North America

Color Yellow powder-coated (RAL 1018)

Material 3 mm steel

Dimensions Cross section Foot

146 mm x 130 mm 230 mm x 190 mm

Weight H2, V2 and N2 H3 H4-1, H4-2 N5

15 kg/piece 17 kg/piece 20 kg/piece 27 kg/piece

Mirror reduction ≤10 %

WWEETT WWAASSHH DDOOWWNN TTUUBBEESS FFOORR PPRROOTTEECCTTIIOONN AAGGAAIINNSSTT WWAATTEERR AANNDD DDUUSSTT

Wet Wash Down Tubes are used for protection against water (or dust) where extreme washing conditions are encountered. The protective encapsulation rating (IP68) now enables Focus II Light Curtains and Light Beams to be used for such applications as the food industry, where the use of high pressure washing for cleaning machinery often occurs. The draining and through ventilation capabilities mean that condensation can be avoided.

Wet, with Focus II Light Curtains/Beams, is preassembled complete with cabling on request. During installation on a machine, a Wet unit can be adjusted by +/- 20º with the accompanying angle bracket. The plastic tube is rotatable and the outside is easy to clean.

WWEETT TTEECCHHNNIICCAALL DDAATTAA

Applications:

■ Protection in severe environments Features

■ Adjustable +/-20º ■ Rotatable and replaceable ■ Capable of draining and through ventilation

Manufacturer ABB AB/Jokab Safety, Sweden

Color Transparent plastic

Length including lid light curtain/Light Beam + 66 mm

Material Tube Lid Angle bracket

PC PEHD-300 Stainless steel

Max. ambient temperature +55°C

Installation adjustment ± 20°

Protection rating IP68 (IP69K)

Page 11: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 9

CCOONNTTRROOLL DDEEVVIICCEESS –– TTWWOO CCHHAANNNNEELLSS IMAGES DESIGNATION ARTICLE NUMBER DESCRIPTION

Safeball – One hand devices

JSTD1-A Safeball 2m cable

2TLA020007R3000

JSTD1-A Safeballs each have 1NO & 1NC independent switches, maximum load of 30VDC - 2A resistive. Ergonomic design with several grip possibilities and low activation force (approx. 2N) and flexible mounting options. Provides highest level of safety for use in two hand control applications when using two Safeballs in conjunction with a JSBR4 safety relay or Pluto Safety PLC. IP67 protection degree, plastic body,2 meters molded cable

JSTD1-B Safeball

200 mm cable

2TLA020007R3100

JSTD1-B Safeballs each have 1NO & 1NC independent switches, maximum load of 30VDC - 2A resistive. Ergonomic design with several grip possibilities and low activation force (approx. 2N) and flexible mounting options. Provides highest level of safety for use in two hand control applications when using two Safeballs in conjunction with a JSBR4 safety relay or Pluto Safety PLC. IP67 protection degree, plastic body, 0.2 m wires × 4 for direct connection into an enclosure.

Safeball – Two hand devices

JSTD20A Twohand

station

2TLA020007R2000

Two-hand device with conventional operating buttons. Operating push buttons are 60 mm in diameter, black, 9N operating force, 1 NO + 1 NC contacts, rated current of 10A. Buttons are mounted in black painted steel housing designed for two-hand applications. IP65. Terminal blocks within housing for connection to buttons. Highest level of safety can be achieved when using in conjunction with a JSBR4 safety relay for two-hand buttons or a Pluto Safety PLC.

JSTD20B Twohand with

Emergency Stop

2TLA020007R2100

Two-hand device with conventional operating buttons and E- stop button. Operating push buttons are 60 mm in diameter, black, 9N operating force, 1 NO + 1 NC contacts, rated current of 10A. E-stop button diameter is 40 mm, 40N operating force, 2 NC positive opening contacts, rated current of 10A. Buttons are mounted in black painted steel housing designed for two hand applications, IP65. Terminal blocks within housing for connection to buttons. Highest level of safety can be achieved when using in conjunction with a JSBR4 safety relay for two hand buttons and RT9/RT6 safety relay for e-stop button or a Pluto Safety PLC.

JSHD-Top units (Three Position Device)

JSHD4-1

2TLA020006R2100

Three-position device.

JSHD4-2

2TLA020006R2200

Three-position device incl. LEDs, front button and top button.

JSHD4-3

2TLA020006R2300

Three-position device incl. LEDs.

Page 12: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 10

JSHD – Bottom part

JSHD4 bottom part AA

2TLA020005R1000

Bottom part with cable gland.

JSHD4 bottom part AB

2TLA020005R1100

Bottom part with Cannon connection.

JSHD4 bottom part AC

2TLA020005R1200 Bottom part with M12 connection (5 poles).

JSHD4 bottom part AD

2TLA020005R1300

Bottom part with M12 connection (8 poles).

AACCCCEESSSSOORRIIEESS,, CCOONNNNEECCTTOORRSS AANNDD CCAABBLLEESS

IMAGES DESIGNATION ARTICLE NUMBER LENGTH DESCRIPTION

JSM C5 Ball & socket mount

2TLA020007R0900

N/A

Flexible mount for mounting the Safeball to Enclosures, Extrusion or table tops.

JSTS31 Floor stand with

distance ring

2TLA020007R4100

N/A

Floor mount stand for JSTD20/25 two-hand devices. Black painted steel with adjustable height lever and distance ring.

M12-C61

2TLA020056R0000

6m

Cable 5 × 0.34 mm2 + screen with straight M12 female connector.

M12-C101

2TLA020056R1000

10m

M12-C61 V 2TLA020056R0100 6m

Cable 5 × 0.34 mm2 + screen with angled M12 female connector.

M12-C101 V 2TLA020056R1100 10m

M12-C62 2TLA020056R0200 6m Cable 5 × 0.34 mm2 + screen with straight M12 male connector. Screen connected to pin3 (0VDC) on male connector. M12-C102 2TLA020056R1200 10m

M12-C612

2TLA020056R2200

6m

Cable 5 × 0.34 mm2 + screen with straight M12 female + male connectors. Screen connected to pin3 (0VDC) on male connector. M12-C1012 2TLA020056R2300 10m

M12-C63

2TLA020056R3000

6m Cable 8 × 0.34 mm2+ screen with straight M12 female connector.

M12-C103

2TLA020056R4000

10m

Note: Cut to length wire is available 5-13 wire.

FFEENNCCIINNGG//MMEECCHHAANNIICCAALL GGUUAARRDDIINNGG SSOOLLUUTTIIOONNSS

Custom CAD designed solution’s… Ask your rep for details.

AALLSSOO AAVVAAIILLAABBLLEE UUPPOONN RREEQQUUEESSTT

Safety Mat’s

Safety Bumper

Safety Rope Switches

Safety Encoders …….and complete safety solution.

Page 13: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch. Page 11

11

MMKKEEYY TTOONNGGUUEE OOPPEERRAATTEEDD SSAAFFEETTYY IINNTTEERRLLOOCCKK SSWWIITTCCHHEESS

Mkey 1 (Plastic)

8 actuator entry positions – rotatable head 3 pole contact block 32 mm wide, 97mm long, 2mm fixed IP67

Mkey 5 (Plastic)

4 actuator entry positions – rotatable head 3 conduit entries 3 pole contact blocks 52mm wide, 98mm long, 40mm fixing Plastic or Stainless Steel Head IP67

MMKKEEYY GGUUAARRDD LLOOCCKKIINNGG SSAAFFEETTYY IINNTTEERRLLOOCCKK SSWWIITTCCHHEESS

MKey 9 Solenoid Locking (Plastic) 8 actuator entry position -rotatable head High Holding Force: 1800N. 2 lock monitoring safety contacts 46mm wide,160mm long,30mm fixing LED 1 status of solenoid applied power LED 2 status of guard lock 2 Emergency manual release points IP67

MKey 8 Solenoid Locking (Metal) 8 actuator entry position -rotatable head High Holding Force: 2000N. Die Cast Alloy 2 lock monitoring safety contacts 46mm wide,176mm long,30mm fixing LED 1 status of solenoid applied power LED 2 status of guard lock 2 Emergency manual release points IP67

MKey 8Z Solenoid Locking (Fully stainless Steel)

8 actuator entry position -rotatable head High Holding Force: 2000N. 2 lock monitoring safety contacts 48mm wide,177mm long,30mm fixing LED 1 status of solenoid applied power LED 2 status of guard lock 2 Emergency manual release points IP67 high temperature hose down

SSTTAANNDDAARRDD VVEERRSSIIOONNSS WWIITTHH RREEAARR MMAANNUUAALL RREELLEEAASSEE BBUUTTTTOONNSS

All the features and specifications of the standard MKey 8 and MKey 8Z are maintained

Where the risk assessment for the application permits, a non-latching manual escape release is provided to enable a quick release of the switch lock in case of emergency.

The switch can be mounted such that access to release button is available from inside the active guard area.

Pressing and holding the red button will release the lock mechanism and open the lock monitoring safety contacts and allow the guard to be pushed open.

Page 14: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 12

PPOOWWEERR TTOO LLOOCCKK VVEERRSSIIOONNSS –– EENNEERRGGIIZZEE TTHHEE SSWWIITTCCHH SSOOLLEENNOOIIDD TTOO KKEEEEPP LLOOCCKKEEDD Only suitable for application where immediate unlocking is required at removal or loss of solenoid power. Not suitable for machines with a running down time.

CCOODDEEDD NNOONN –– CCOONNTTAACCTT SSAAFFEETTYY SSWWIITTCCHHEESS

When the guard is closed the switch actuator will only lock the safety contacts to close after the solenoid is energized. The guard will be held closed and can only be opened after the solenoid is de – energized either by controlled request (or by power loss). A latching Stop/Start circuit or a PLC or Safety PLC machine command usually energizes the solenoid.

Features:

Dual channel electronic safety output 2NC (1No auxiliary optional)

Visual LED indication of switch status

Enclosure Protection to IP67 or IP69K –wash down suitable

Conformance to IEC 947-5-3 PDF-S

No moving parts to give high reliability and long life

Wide sensing distance 14mm

Plastic versions: The Plastic Sense range has been developed for non-contact guard door interlocking in the applications of general factory automation packaging and some food processing industries.

Page 15: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch. Page 13

13

Stainless Steel 316 versions:

Magnetic NON – Contact Safety Switches are also available.

EE –– SSTTRROONNGG ZZ HHEEAAVVYY DDUUTTYY EEMMEERRGGEENNCCYY SSTTOOPP SSWWIITTCCHHEESS

Features: Stainless Steel 316 housings (IP69K) Conformance to ISO 13850, IEC 947-5-1 and IEC 947-5-5 A special lid safety trip mechanism means that the safety

contacts will open if the lid is removed Button protection shroud version with Padlock holes for

‘Lock off’ During maintenance Optional 2 colour LED

Page 16: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 14

LLIINNEE SSTTRROONNGG SSEERRIIEESS –– GGRRAABB WWIIRREE SSAAFFEETTYY RROOPPEE SSWWIITTCCHHEESS

Features:

LED visual indication of Rope status: Steady Green – Machine Running Steady or Flashing Red – Machine Stopped

Rugged die-cast metal body – Yellow colour

Stainless steel 317 Housings are available (Z versions) – ideal for the food industry

All internal and external screws and fittings are Stainless Steel

Enclosure protection to IP67 – wash-down suitable (IP69K on Stainless Steel Versions)

Easy to wire – up to 4 conduit entries

Page 17: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 15

EEDDGGEE 11 SSAAFFEETTYY LLIIMMIITT SSWWIITTCCHHEESS

Features:

Positive opening safety contacts to IEC 947-5-1

Choice of 11 actuator heads Linear, Rotary and Flexible actions

High Mechanical Life - 10,000,000 cycles

Head position adjustment any of 4 positions

Enclosure Protection to IP 67 – wash down suitable

Conduit entries: M20 ½” NPT or Quick connect

Edge 1R Safety limit switches with reset

Edge 2 and Edge 3 Safety limit switches

Page 18: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch.

Page 16

NNOOTTEESS ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ………………………………………………………………………………………………………………………

CCUUSSTTOOMMEERR IINNFFOORRMMAATTIIOONN

Contact:

Position:

Company:

Address: City, Postal Code:

Phone: Fax:

E-Mail:

Page 19: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

For additional information on the products and delivery, contact your local branch. Page 17

NNOOTTEESS ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ……………………………………………………………………………………………………………………… ………………………………………………………………………………………………………………………

Page 20: SAFETY PRODUCTS L A T CA S UCT ROD P Y FET A S 2013Safety+catalogue+2013.pdf · 2015. 10. 29. · 2013. SAAFFEETTYY ... Dangerous Failure per Hour—PFHd. Method in EN 62061 for Assigning

The One Stop Shop

CONTROL PRODUCTS AC & DC Contactors Cam Switches Definite Purpose Contactors Drives Electronic Timers Lighting Contactors Limit Switches Magnetic Starters Manual Motor Starters PLC Proximity Switches, Photoelectric & Ultrasonic Sensors Pushbuttons, Stacklights and Beacons Relays Safety and Monitoring Relays Soft Starters Wiring Ducts

POWER QUALITY PRODUCTS Active Filter Anti-Resonance Capacitor Banks Automatic Capacitor Banks Dynacomp Fixed Capacitor Banks Harmonic Filter (shunt) Individual Capacitors Surge Capacitors

CIRCUIT PROTECTIVE DEVICES Arc Guard Monitor Disconnect Switches Low Voltage Power Circuit Breakers Molded Case Circuit Breakers Supplementary Protectors

Head Office BURLINGTON

4104 South Service Road Burlington, Ontario L7L 4X5

Tel: (905) 681-3656 Fax: (905) 681-1774

www.gerrie.com

KITCHENER 107 Manitou Drive

Kitchener, Ontario N2C 1L4 Tel: (519) 893-1932 Fax: (519) 893-4462

MISSISSAUGA

1221 Matheson Blvd. E Mississauga, Ontario L4W 1B6

Tel: (905) 625-3118 Fax: (905) 625-5714

GUELPH

31 Arrow Road Guelph, Ontario N1K 1S8

Tel: (519) 823-8442

Fax: (519) 823-0068

CAMBRIDGE

1195 Franklin Blvd. Cambridge, Ontario N1R 7R7

Tel: (519) 740-2912

Fax: (519) 740-2833

LONDON HYDE PARK 6-2018 Mallard Road

London, Ontario N6H 5L8 Tel: (519) 641-4321 Fax: (519) 641-4323

ST. THOMAS

156 Edward St. Unit 3 St. Thomas, Ontario N5P 1Z3

Tel: (519) 633-1400 Fax: (519) 633-0995

WOODSTOCK

7-1057 Parkinson Road Woodstock, Ontario N4S 7W3

Tel: (519) 539-4789 Fax: (519) 539-4385

Gerrie Electric Subsidiary

Bramtor Electric Supply Co. Ltd 23 Strathearn Avenue

Brampton, Ontario L6T 4P1 Tel: (905) 792-1111 Fax: (905) 792-0718

LONDON 1183 Frances Street

London, Ontario N5W 2L9 Tel: (519) 659-1234 Fax: (519) 659-8338