SAVER™ Field Data RecorderThe award-winning SAVER™ is a Shock and Vibration Environmental Recorder. The SAVER™ measures the actual transportation environment and allows the user to evaluate the efficiency and effectiveness of both package and product design. SAVER™ is a rugged, powerful, and flexible tool. The SAVER™ measures tri-axial acceleration, temperature, and humidity. An internal clock and optional GPS reveal the exact time and location of each shock and vibration event. The SAVER™ has eight dynamic channels for measurement of acceleration and six static channels for measurement of temperature, humidity, pressure, and GPS.

The SAVER™ can be utilized to:

• Ruggedize product design to reduce loss and damage

• Improve package design to increase protection and reduce costs

• Perform due diligence for insurance and risk management

• Define harmful dynamics of your product transportation environment

• Audit transit environments to assess carrier handling practices

• Capture and export both time and frequency results to replicate your transportation environment instead of relying on standards set by others

Features:

• Sophisticated measurement and analysis including drop height, vibration and shock, temperature, humidity, shock response spectrum, and vibration PSD.

• Easy-to-use Windows™ compatible software

• Portability—SAVER™ is truly portable with a built-in battery, 2.2 pound weight, and 39 cubic inch size

• Resolution—SAVER™ digitizes waveforms with 12 bits giving it 16 times more resolution than an 8 bit instrument.

• Expansibility—SAVER™ may be expanded with a variety of options and additional memory. Optional expanded memory allows for 1000’s of waveforms to be stored.

• Worldwide Customer Service department

Page 2: SAVER™ Field Data Recorder - · PDF file• Portability—SAVER™ is truly portable with a built-in battery, 2.2 pound weight, and 39 cubic inch size ... saverfamily_FINAL_rev2a.indd

PHYSICALEnvelope Size 4.9 x 3.8 x 2.2 inches (125 x 96 x 56 mm)

Volume 39 cu. in. (639 cu. cm.)

Case Material 6061-T6 aluminium, clear alodine fi nish

Weight 2.2 lbs. (1 kg.)

Mounting Mounting bars recommendedHoles for #8 screwsMagnetic mounts optional

DATA HANDLINGData Conversion Resolution, bits: 12 (4095 Counts)

Dynamic Range: 62 db typical

Number of Channels 14 User Channels8 Dynamic Channels

4 Acceleration & 4 Optional Voltage (Std.)8 Acceleration (optional)

6 Static ChannelsBuilt-In TemperatureBuilt-In Relative HumidityRemote T&RH Probe2 Voltage-Input

Voltage-Input Channels 0 to 5V DC, or ± 2.5V AC, single ended, specifi ed at time of order.

Maximum Source Impedance for Voltage Channels

600 ohms

Maximum Sample Rate 1800 to 7200 samples per second per channel depending on number of active channelsExamples:

7200 s/s per channel for 1 channel4000 s/s per channel for 3 channels1800 s/s per channel for 8 channels

Triggering Threshold (Single Triggering)Asymmetrical +/- for each Waveform channelTrig. condition above or below thresholdProgrammable Logic Triggering AND, OR, NOTTime Triggering 1 second to 12 hoursExternal Triggering

MEMORYMemory Standard 1 Mb Static RAM

Optional Maximum Memory 4 Mb, 8 Mb, 16 Mb

Memory Modes Fill/stop, wrap, max

Memory Partitioning(Program Selectable)

Separated between Signal and Time-Triggered data

Speed of Communication with Host

Nominal 1 Mbyte/minute via parallel port

Automated Setups “Gateways” for shock, vibration, drop heights, etc..

SYSTEM CONFIGURATIONFurnished Host Software Proprietary, Windows™ 95, 98

Automated Setups “Gateways” for shock, vibration, drop heights, etc..

Standard Analyses(Graphical, Tabular)

Confi gured for different analysis modes, quick history, event table, event viewer, event analysis and analysis summary

SENSING

International Accelerometers (Standard)

Tri-axial, Piezoelectric

External Accelerometers (Optional)

Piezoelectric, 2.0 to 3.5 pC/g, capacitance 2000 pf or less

Acceleration Ranges(Program Selectable)

5,10, 20, 50, 100, 200g full scale. May be different ranges for different channels

Acceleration Channel Filters (Program Selectable)

Nominal 20 Hz. to 2560 Hz. in 20 Hz. increments

Acceleration Channel Filter Characteristics

2-pole, low-pass

Acceleration ChannelFrequency Response

0.4 Hz. to fi lter maximum (Std..)DC to fi lter maximum (Optional)

Typical AccelerationChannel Accuracy

± 5% with nominal variations in temperature and frequency

Built-In Temperature andRH Transducers

Standard

Remote Temperature andRH Transducers

Optionally available

Atmospheric Pressure Probe Optionally available

Temperature Measurement Range

-20˚ to 167˚ F (-29˚ to 75˚ C)

Relative Humidity Measurement Range

5 to 95% non-condensing at 25˚C

Temperature Measurement Accuracy

± 1.1˚ C

Humidity MeasurementAccuracy

± 3% at 25˚ C

ENVIRONMENTALPower Supply Disposable alkaline batteries, C size.

Wall-plug 3.0 vdc external power

Operating Temperature Range -20˚ to 130˚ F (-29˚ to +55˚ C)

Continuous Recording Time Up to 28 days on internal batteries. Depending on environmental conditions and recording setup

Data Retention(Backup Battery)

Up to 1 year after main batteries are removed or exhausted

Extended Recording Time Optional external battery pack doubles recording time, 3 vdc max.

Controls and Indicators Power On/OffWeather-Resistant, Indicator LED, fl ashes status and accessible information without case disassembly

OPTIONAL ACCESSORIESExtended Life Battery PackExternal Temperature/Humidity PackMagnetic Mounting BracketsExternal AccelerometersAtmospheric Pressure ProbeDC Accelerometer Frequency ResponseTrigger Detector

SAVER™ Field Data RecorderTECHNICAL SPECIFICATIONS

SAVER™ Field Data Recorder