sc 3201 heat pump hardwired programmable electronic …electrical rating: • 24 vac (18-30 vac) •...
TRANSCRIPT
![Page 1: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/1.jpg)
Heat Pump 7-Day Programmable
HardwiredSC 3201Programmable Electronic Thermostat
Installation, Operation & Application GuideFor more information on our complete range of American-made products – plus wiring diagrams, troubleshooting tips and more, visit us at www.icmcontrols.com
•7-DayProgrammable
•2-StageHeatPump
•BacklitDisplay
•ManualChangeover
•Simpleset®Programming
•Title24Compliant/NoBatteriesRequired
•RelayOutputs(minimumvoltagedropinthermostat)
•IdeallySuitedfor:–Residential(NewConstruction/Replacement), LightCommercial
![Page 2: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/2.jpg)
Table of Contents
SimpleComfort®3201PartsDiagram.......................................................................................... 1Specifications.............................................................................................................................. 2ImportantSafetyInformation..................................................................................................... 2PackageContents/ToolsRequired............................................................................................... 2ToRemoveExistingThermostat................................................................................................ 3ToInstallThermostat.................................................................................................................. 3WiringDiagramConversions.................................................................................................. 5-16ModeofOperation.................................................................................................................... 17LEDIndicators.......................................................................................................................... 18StartingtheThermostat........................................................................................................... 19TestingtheThermostat............................................................................................................ 20OperatingModes...................................................................................................................... 22SettingtheTimeandDayoftheWeek..................................................................................... 23Programming............................................................................................................................ 24Simpleset®Programming.......................................................................................................... 26FactoryPreprogramming.......................................................................................................... 26PersonalProgramSchedule...................................................................................................... 27Troubleshooting........................................................................................................................ 29
![Page 3: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/3.jpg)
�
SimpleComfort® 3201 Parts Diagram
Fan Switch
Reset Button
Cool EmerOff
OnAuto
Heat
Y2Y1EGW2OB
Mode/Hold Switch
System Switch
C
L
R
Mode Hold
![Page 4: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/4.jpg)
�
ElectricalRating: •24VAC(18-30VAC) •1ampmaximumperterminal •4ampmaximumtotalload •60minutepowerlossbackupforclockTemperaturecontrolrange:45°Fto90°F(7°Cto32°C)Accuracy:±1°F(±0.5°C)Systemconfigurations:2-stageheat,2-stagecool,heatpumpTerminations:C,L,R,B,O,W2,G,E,Y1,Y2
Specifications
WARNING!:Alwaysturnoffpoweratthemainpowersupplybeforeinstalling,cleaning,orremovingthermostat.
•Thisthermostatisfor24VACapplicationsonly;donotuseonvoltagesover30VAC•Allwiringmustconformtolocalandnationalelectricalandbuildingcodes•Donotuseairconditioningwhentheoutdoortemperatureisbelow50degrees;thiscandamageyour
A/Csystemandcausepersonalinjuries•Usethisthermostatonlyasdescribedinthismanual
Important Safety Information
Packageincludes:SimpleComfort®3201programmablethermostatonbase,labeledthermostatcover,wiringlabels,screwsandwallanchors,Installation,OperationandApplicationGuide.
Toolsrequiredforinstallation:Drillwith3/16”bit,hammer,screwdriver.
Package Contents/Tools Required
![Page 5: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/5.jpg)
�
ELECTRICALSHOCKHAZARD–TurnoffpoweratthemainservicepanelbyremovingthefuseorswitchingtheappropriatecircuitbreakertotheOFFpositionbeforeremovingtheexistingthermostat.
1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingtheappropriatecircuitbreakeroff.
2. Removecoverofoldthermostat.Thisshouldexposethewires.
3. Labeltheexistingwireswiththeenclosedwirelabelsbeforeremovingwires.
4. Afterlabelingwires,removewiresfromwireterminals.
5. Removeexistingthermostatbasefromwall.
6. Refertothefollowingsectionforinstructionsonhowtoinstallthisthermostat.
To Remove Existing Thermostat
ELECTRICALSHOCKHAZARD–TurnoffpoweratthemainservicepanelbyremovingthefuseorswitchingtheappropriatecircuitbreakertotheOFFpositionbeforeremovingtheexistingthermostat.
IMPORTANT:Thermostatinstallationmustconformtolocalandnationalbuildingandelectricalcodesandordinances.
Note:Mountthethermostataboutfivefeetabovethefloor.Donotmountthethermostatonanoutsidewall,indirectsunlight,behindadoor,orinanareaaffectedbyaventorduct.
1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingtheappropriatecircuitbreakeroff.MovetheSystemswitchtoOFF.
To Install Thermostat
![Page 6: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/6.jpg)
�
To Install Thermostat (continued)2. Toremovecover,insertandtwistacoinorscrewdriverintheslotsonthesidesofthethermostat.
3. Putthermostatbaseagainstthewallwhereyouplantomountit(Besurewireswillfeedthroughthewireopeninginthebaseofthethermostat).
4. Marktheplacementofthemountingholes.
5. Setthermostatbaseandcoverawayfromworkingarea.
6. Usinga3/16”drillbit,drillholesintheplacesyouhavemarkedformounting.
7. Useahammertotapsuppliedanchorsinmountingholes.
8. Alignthermostatbasewithmountingholesandfeedthecontrolwiresthroughthewireopening.
9. Usesuppliedscrewstomountthermostatbasetowall.
10. Insertstripped,labeledwiresinmatchingwireterminals.See“WiringDiagrams”sectionofthismanual(Pages5-16).
CAUTION!:Besureexposedportionofwiresdoesnottouchotherwires.
11. Tightenscrewsonterminalblock.Gentlytugwiretobesureofproperconnection.Doublecheckthateachwireisconnectedtotheproperterminal.
12. Sealholeforwiresbehindthermostatwithnon-flammableinsulationorputty.
13. Replacecoveronthermostatbysnappingitinplace.
14. Turnonpowertothesystematthemainservicepanel.
15. Testthermostatoperationasdescribedin“TestingtheThermostat”(Page20).
![Page 7: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/7.jpg)
�
Wiring Diagrams
SimpleComfort®3201ElectronicThermostatConversionto:Carrier Split Stream Condensers and Heat Pump Systems
SC 3201 Electronic Thermostat
![Page 8: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/8.jpg)
�
SimpleComfort®3201ElectronicThermostatConversionto:Coleman 3000 Series Heat Pump Systems
SC 3201 Electronic Thermostat
![Page 9: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/9.jpg)
�
SimpleComfort®3201ElectronicThermostatConversionto:Comfortmaker CYC Series Heat Pump Systems
SC 3201 Electronic Thermostat
(capped)
(capped)
![Page 10: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/10.jpg)
�
SimpleComfort®3201ElectronicThermostatConversionto:Heil-Quaker 867.814 Series and PH50 Series Heat Pump Systems
SC 3201 Electronic Thermostat
(capped)
![Page 11: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/11.jpg)
�
SimpleComfort®3201ElectronicThermostatConversionto:Payne Reliant and Endura Model Heat Pump Systems
SC 3201 Electronic Thermostat
(capped)
![Page 12: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/12.jpg)
�0
SimpleComfort®3201ElectronicThermostatConversionto:Rheem/Ruud: -PGB, -PFA, -PCB, -PLA, and -PKA Series Heat Pump Systems
SC 3201 Electronic Thermostat
![Page 13: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/13.jpg)
��
SimpleComfort®3201ElectronicThermostatConversionto:Goodman, Janitrol, Trane/American Standard Heat Pumps
SC 3201 Electronic Thermostat
(capped)
(capped)
![Page 14: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/14.jpg)
��
SimpleComfort®3201ElectronicThermostatConversionto:York E1CS, E1FB, E1FH Heat Pump Systems
SC 3201 Electronic Thermostat
![Page 15: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/15.jpg)
��
SimpleComfort®3201ElectronicThermostatConversionto:Lennox CB19 Heat Pump Systems
SC 3201 Electronic Thermostat
![Page 16: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/16.jpg)
��
SimpleComfort®3201ElectronicThermostatConversionto:Lennox HP19 and HP20 Heat Pump Systems
SC 3201 Electronic Thermostat
![Page 17: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/17.jpg)
��
SimpleComfort®3201ElectronicThermostatConversionto:Lennox HP21 With CB21 PCB Heat Pump Systems
SC 3201 Electronic Thermostat
![Page 18: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/18.jpg)
��
SimpleComfort®3201ElectronicThermostatConversionto:Lennox HP22 With CB19 PCB Heat Pump Systems
SC 3201 Electronic Thermostat
![Page 19: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/19.jpg)
��
TheSimpleComfort®3201thermostathasbuttonsthatareusedto:
•Adjustthesetpointsofthethermostat•Setthemodes•Programtheschedule
Setting the Room Temperature (Setpoint Temperature)1.WiththeSystemswitchinCool,Heat,orEmer,thecurrenttemperaturesetpointdisplays.
2.Pressthe or buttonuntilthedesiredtemperaturesetpointdisplays.3.Thenewtemperaturesetpointisautomaticallysavedinmemory.
Setting a New Temperature Differential1.Thedefaulttemperaturedifferentialis1°.Whenyourroomtemperaturevariesby1°F,thethermostat
turnsonyoursystem.Ifyounoticeyoursystemturningonandofftoofrequently,increasethetemperaturedifferential.
2.PlacetheSystemswitchinOFFposition.
3.Pressboth and buttonssimultaneously.
4.Pressthe or buttontoselectdesiredsetting.5.Whenfinished,moveSystemswitchtoHeatorCoolpositiontolocksettingintomemory.
Operation
![Page 20: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/20.jpg)
��
TherearethreeLEDindicatorslocatedonthefrontofthethermostat.Theyaredesignedtoinformyouaboutthefollowing:
LED Color Function
AUX Green •Thisturnsonwhentheauxiliary(backup)heatingisinoperation
•Thisisthesecond(non-economy)stageofheat
•Itturnson2degreesbelowfirststageandisnotadjustable
CHECK Red •Whenthisturnson,amalfunctionhasoccurredsomewhereintheheatpumpsystem
•Pleasecontactaqualifiedservicetechnicianassoonaspossibletocheckyoursystem
EMER Red •Thislightturnsonwhenevertheemergencyheatismanuallyselected(SystemswitchisintheEMERposition)
•WhileintheemergencyHeatmode,theheatpumpcompressorisoff,andtheemergencyheat(sameastheauxiliaryheat)maintainsthesetpointtemperature
LED Indictors
![Page 21: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/21.jpg)
��
CAUTION!: Donotuseairconditioningwhentheoutdoortemperatureisbelow50degrees.Thiscandamageyourairconditioningsystemandcausepersonalinjuries.
1. MovetheFanAuto/OnswitchtotheAutoposition.Onpositionrunsindoorfancontinuously.2. MovetheSystemswitchtoCoolorHeat,dependingontheseason.
Starting the Thermostat
Fan Switch
Mode/Hold Switch
System Switch
![Page 22: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/22.jpg)
�0
Oncethethermostatisinstalled,itshouldbethoroughlytested. CAUTION!:Donotenergizetheairconditioningsystemwhentheoutdoortemperatureisbelow
50degrees.Itcanresultinequipmentdamageorpersonalinjury. Note:BeforetestingtheSC3201,movetheFanAuto/OnswitchtotheAutoposition.
CoolTest1. SlideSystemswitchtoCoolposition.Coolmodescreenisdisplayed.2. Adjustsettemperaturesoitis5degreesbelowroomtemperature.3. Airconditioningshouldcomeonwithinafewseconds.4. Adjustthesettemperature2degreesabovetheroomtemperature
andtheA/CshouldturnOff.Theremaybeafandelayonyoursystem.
Note:Thereisafour-minutetimedelaytoprotectthecompressorafteritturnsOff.Tobypassthefour-minutedelay,slidetheSystemswitchtoOffandbacktoCoolmode.
HeatTest1.SlideSystemswitchtoHeatposition.Heatmodescreenisdisplayed.2.Adjustthesettemperaturesoitis5degreesabovetheroom
temperature.3.Heatshouldcomeonwithinafewseconds.AuxLEDturnsON.4.Adjustthesettemperaturesoitis2degreesbelowtheroom
temperatureandtheheatshouldturnOff.Theremaybeafandelayonyoursystem.
Note:Thereisafour-minutedelaytoprotectyourcompressor.Tobypassthefour-minutedelay,slidetheSystemswitchtoOffandbacktoHeatmode.
Testing the Thermostat
![Page 23: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/23.jpg)
��
EmergencyHeatTest1.SlideSystemswitchtoEmerposition.EmerHeatmodescreenisdisplayed(EmerLEDlights).2.Adjustsettemperaturesoitis5degreesaboveroomtemperature.3.Secondstageheatshouldcomeonwithinafewseconds(AuxLEDlights).4.Adjustthesettemperature2degreesbelowtheroomtemperatureandtheheatshouldturnoff.There
maybeafandelayonyoursystem.
FanTest1.SlideFanswitchtoOnposition.2.Indoorfanturnson.3.SlideFanswitchtoAutoposition.4.Indoorfanturnsoff.
![Page 24: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/24.jpg)
��
OffMode•Inthismode,thethermostatwillnotturnontheheatingor
coolingdevices(manualfancanoperate)•OFFmodeisalsousedtoaccessSetupandProgrammodes
CoolMode•Inthismode,thethermostatcontrolsthecoolingsystem•PresstheModebuttontoenterandexitProgramCoolmode•InProgramCool(PROGdisplays)mode,thethermostatwillfollowtheprogram
schedulethatisstoredinmemory
HeatMode•Inthismode,thethermostatcontrolstheheatingsystem•PresstheModebuttontoenter/exittheProgramHeatmode•InProgramHeat(PROGdisplays)mode,thethermostatwillfollowtheprogramschedulethatis
storedinmemory
EmergencyMode•Inthismode,thethermostatcontrolstheheatingsystem,butbypassestheheatpumpsystem•PresstheModebuttontoenter/exittheProgramEmerHeatmode•InProgramEmerHeat(PROGdisplays)mode,thethermostatwillfollowtheprogramschedulethatis
storedinmemory
Note:ProgramEmerHeatmodefollowsthesameschedulesetforProgramHeatmode.
HoldWheninProgrammableCool,ProgrammableHeat,orProgrammableEmerHeat,youcanlockinthepresentsettingsindefinitelybypressingtheHoldbuttononce(PROGflashes).PressHoldbuttonagaintoleaveHoldmode(PROGsolid).ForatemporaryHoldperiod,raiseorlowersettemperaturetodesiredsettemperature.Thethermostatwillautomaticallyreturntoprogrammedsettemperatureafter2hours.
Operating Modes
![Page 25: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/25.jpg)
��
Thetimeanddayoftheweekmustbesetforyourprogramscheduletooperatecorrectly.
1. SlidetheSystemswitchintotheOFFposition.
4. Pressthe buttonwhilethetimeisdisplayed.Thedisplayshowsthedaycurrentlysetonthethermostat(1=Monday,2=Tuesday,etc).
5. Pressthe or buttontosetthecorrectdayoftheweekthattodayis.
Note:SlidingtheSystemswitchtoCoolorHeatpositionswilllockthevaluesintomemory.Youmayalsopressthe buttontoenteryourprogrammingschedule.
2. Pressthe buttoninfor6seconds.
3. Pressthe or buttontoadjustthetime.
Setting the Time and Day of the Week
![Page 26: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/26.jpg)
��
Program OverviewTheSC3201programmablethermostathasfourperiods(MORN,DAY,EVE,NITE)thatarecustomizableforeachdayoftheweek.Eachperiodwillhaveasettime,heattemperature,andcooltemperature.TheSC3201monitorsthedayandtime,whilemaintainingthespecificconditionsyouhavechosenforeachperiodinyourprogram.
1.PlaceSystemswitchinOFFposition.
2.Pressthe buttonfor6seconds.
3.Pressthe buttontwice.
•Dayisdisplayed(1-7)
4.Pressthe or buttontochangethedayyouwanttoprogram(1=Monday,2=Tuesday,etc.).
5.Pressthe buttontoadvancetothenextparameter.
Note:Youcanalwayspressthe buttontoreturntothepreviousparameter.
•Periodisdisplayed(MORN,DAY,EVE,NITE)
6.Pressthe or buttontochangeperiodofday.
7.Pressthe buttontoadvancetothenextparameter.
Programming
![Page 27: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/27.jpg)
��
Programming (continued)
•Settimeisdisplayed
8. Pressthe or buttontochangesettime.9. Pressthe buttontoadvancetothenextscreen. Note:Transitionsrequiredafter11:59PMmustbeprogrammedinthe
nextday’sMORNperiod.
•Heattemperatureisdisplayed(50°Fto90°F) 10. Pressthe or buttontoadjustheatsettemperature.11. Pressthe buttontoadvancetothenextscreen.
•Cooltemperatureisdisplayed(45°Fto85°F) 12. Pressthe or buttontoadjustcoolsettemperature.13. Pressthe buttontoadvancetothenextscreen.
Repeatsteps1-13toprogrameachdayoftheweekindividuallyorusetheSimpleset®feature(seePage26)toprogrameverydaythesameasMonday.
Whenprogrammingiscomplete,slidetheSystemswitchtoHeatorCooltoexitProgrammingMode.YourprogramschedulewillbesavedinmemoryandyouwillbereturnedtotheOffmode.
![Page 28: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/28.jpg)
��
Simpleset®programmingisaconvenientmethodofprogrammingthethermostat.OncetheentireMonday(Day1)scheduleisset,Simpleset®programmingwillcopytheMondayscheduletoeverydayoftheweek.
AfterthecompleteMondayscheduleisset(seeProgrammingonPage24),youareattheDay2screen:1.Pressthe buttononce.Day1screendisplays.2.Pressthe buttonfor2seconds.
•Thedaysoftheweekwillcountdownfrom7to1andthiswilllockthesettingsintomemory.
•Oncethescheduleislockedin,youcangothrougheachdayandmakeanychangesyourequire.Thisfeaturespeedsuptheprogrammingofthestandardweekday/weekendschedule.
3.SlidetheSystemswitchtoHeatorCooltoexitProgrammingMode.
TheSC3201comespreprogrammedwiththefollowingschedule:
MORN 6:00 AM DAY 8:00 AM EVE 6:00 PM NITE 10:00 PMHEAT 70°F HEAT 62°F HEAT 70°F HEAT 62°FCOOL 78°F COOL 85°F COOL 78°F COOL 82°F
MONDAYthru
SUNDAY
Factory Preprogramming
Simpleset® Programming
![Page 29: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/29.jpg)
��
Usethefollowingpersonalprogramscheduletorecordyoursettings:
MORN DAY EVE NITEHEAT HEAT HEAT HEATCOOL COOL COOL COOL
MONDAY1
MORN DAY EVE NITEHEAT HEAT HEAT HEATCOOL COOL COOL COOL
TUESDAY2
MORN DAY EVE NITEHEAT HEAT HEAT HEATCOOL COOL COOL COOL
WEDNESDAY3
MORN DAY EVE NITEHEAT HEAT HEAT HEATCOOL COOL COOL COOL
THURSDAY4
Personal Program Schedule
![Page 30: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/30.jpg)
��
Personal Program Schedule (continued)
MORN DAY EVE NITEHEAT HEAT HEAT HEATCOOL COOL COOL COOL
FRIDAY5
MORN DAY EVE NITEHEAT HEAT HEAT HEATCOOL COOL COOL COOL
SATURDAY6
MORN DAY EVE NITEHEAT HEAT HEAT HEATCOOL COOL COOL COOL
SUNDAY7
![Page 31: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/31.jpg)
��
Symptom RemedyNodisplay Checkfor24VACatthermostat;displayisblankwhen24VACisnotpresent
Systemfandoesnotcomeonproperly Verifywiringiscorrect
Allthermostatbuttonsareinoperative Verify24VACispresent;unitlocksoutwhen24VACisnotpresent
Programscheduleactivatesatthewrongtime
Checktime(AM/PM)setonthermostat(see“SettingtheTime,”Page23)
Thermostatturnsonandofftoofrequently
Adjusttemperaturedifferential(See“SettingaNewTemperatureDifferential,”Page17)
Thermostatdoesnotfollowprogram VerifyitisoperatinginProgrammode(PROGdisplayssolid);checktime(AM/PM);checkifinHoldmode(PROGflashesinHoldmode)
“PROGram”flashes(inHoldmode) PressHoldbuttontoremovefromHoldmode
Fanrunscontinuously CheckFanOn/Autoswitch;fanrunscontinuouslywhenfanswitchisinONposition
Roomtemperatureisnotcorrect Verifywallholeforwiresispluggedwithputtyorinsulation
Problemnotlistedabove PressResetbuttononce*
*ResetButtonFunction Time,dayandmodechangedtolastsavedsettings(savedafterpowerlossorwhenexitingprogramsetup);configurationandprogramsettingsareunchanged.
Troubleshooting
![Page 32: SC 3201 Heat Pump Hardwired Programmable Electronic …Electrical Rating: • 24 VAC (18-30 VAC) • 1 amp maximum per terminal • 4 amp maximum total load • 60 minute power loss](https://reader036.vdocument.in/reader036/viewer/2022062606/6018b00b86c7567b2a03664e/html5/thumbnails/32.jpg)
ONE-YEAR LIMITED WARRANTYTheSellerwarrantsitsproductsagainstdefectsinmaterialorworkmanshipforaperiodofone(1)yearfromthedateofmanufacture.TheliabilityoftheSellerislimited,atitsoption,torepair,replaceorissueanon-casecreditforthepurchasepricesofthegoodswhichareprovidedtobedefective.ThewarrantyandremediessetforthhereindonotapplytoanygoodsorpartsthereofwhichhavebeensubjectedtomisuseincludinganyuseorapplicationinviolationoftheSeller’sinstructions,neglect,tampering,improperstorage,incorrectinstallationorservicingnotperformedbytheSeller.InordertopermittheSellertoproperlyadministerthewarranty,theBuyershall:1)NotifytheSellerpromptlyofanyclaim,submittingdatecodeinformationoranyotherpertinentdataasrequestedbytheSeller.2)PermittheSellertoinspectandtesttheproductclaimedtobedefective.ItemsclaimedtobedefectiveandaredeterminedbySellertobenon-defectivearesubjecttoa$30.00perhourinspectionfee.ThiswarrantyconstitutestheSeller’ssoleliabilityhereunderandisinlieuofanyotherwarrantyexpressed,impliedorstatutory.Unlessotherwisestatedinwriting,Sellermakesnowarrantythatthegoodsdepictedordescribedhereinarefitforanyparticularpurpose.
LIA159-4
Patent No. ���,������� William Barry Blvd., North Syracuse, NY �����
(Toll Free) 800-365-5525 (Phone) 315-233-5266 (Fax) 315-233-5276
www.icmcontrols.com