sd500 technical data - sivasa-ec.com · ㅇcooling method fresh water forced circulation ... sd500...
TRANSCRIPT
SIVASA Doosan Series
SD500 Technical Data
Doosan P158LE
500KVA at 60Hz, 460V
♦ Assembled by Doosan diesel engine and Leroy Somer alternator.
♦ Three filters as standard, fuel and water separator as optional.
♦ Radiator and fan with safety guard.
♦ Single bearing alternator IP 23, Insulation Class H.
♦ Heavy duty steel as base frame and 8hrs operation base fuel tank.
♦ Automatic control panel and 3 poles circuit breaker, internal cable.
♦ 12V or 24V battery, battery wires.
♦ Battery charger and float battery charger as standard supply scope.
♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers.
Genset Main Technical Data:
Powered by
General feature:
Genset Model SD500Prime Power(60HZ) 360KW/450KVA
Standby Power(60HZ) 400KW/500KVA
Frequency/Speed 60HZ/1800rpm
Standard Voltage 460V
Voltage Available
Phases Three phases
Wires Four wires
(1) PRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications,
in
accordance with ISO8528-1. A 10% overload capability is available for a period of 1 hour within 12-hour period
of
operation. In accordance with ISO 3046-1.
(2) ESP: The Standby Power Rating is applicable for supplying emergency power in variable load applications for
SIVASA Doosan Series
SD500 Technical Data
Doosan Engine Data:
Manufacturer Doosan Engines Company Limited
Model P158LE
Engine speed 1800rpm
Engine power
----------------------------Standby power 402kw
----------------------------Prime power 444kw
Type 4 stroke cycle , V type, 8 cylinder
Aspiration Turbo charged & intercooled (air to air)
Bore * Stroke 128*142 mm
Cubic capacity 14.618 L
Compression ratio 15:1
Fuel Consumption:
Standby powerType of operation and application
g/kWhr l/hr
25% 25.6
50% 51.25
75% 76.87
100% 102.5
Lubrication system:
ㅇLub. Method Fully forced pressure feed type
ㅇOil pump Gear type driven by crankshaft
ㅇOil filter Full flow, cartridge type
ㅇOil pan capacity High level 28 liters ( 7.4 gal.) Low level 26 liters (
6.86 gal.)
ㅇAngularity limitFront down 35 deg Front up 35 deg. Side to
side 35 deg.
SIVASA Doosan Series
SD500 Technical Data
Fuel system:
ㅇInjection pump Bosch in-line “P” type
ㅇGovernor Electrical type
ㅇFeed pump Mechanical type
ㅇInjection nozzle Multi hole type
ㅇOpening pressure 285 kg/cm2 (4.054 psi)
ㅇFuel filter Full flow, cartridge type
ㅇUsed fuel Diesel fuel oil
Cooling system:
ㅇCooling method Fresh water forced circulation
ㅇWater capacity (engine only) 20 liters ( 5.28 gal.)
ㅇPressure system Max. 0.9 kg/cm2 ( 12.8 psi)
ㅇWater pump Centrifugal type driven by belt
ㅇThermostatWax – pellet type
Opening temp. 71°C Full open temp. 85°C
ㅇCooling fan Blower type, steel 915 mm diameter, 7 blade
Electric system:
ㅇCharging generator 24V x 45A alternator
starter motor 24V x 7.0kW
SIVASA Doosan Series
SD500 Technical Data
ALTERNATOR Specifications:
Manufacturer Leroy-somer Electro-technique (Fuzhou) Company
Model LSA47.2VS2
Output power 365KW
AVR model R250
Number of phase 3
Power factor (Cos Phi) 0.8
Termianls 12
Altitude ≤ 1000 m
Overspeed 1950RPM
Number of Pole 4
Exciter type Shunt
Insulation class H
Voltage regulation ±1%
Wave form : I.E.C. = THF < 2%
Bearing single
Sustained short circuit current 300% (3 IN) : 10s
Total harmonics (TGH/THC) no load < 3% - on load < 2%
Wave form : NEMA = TIF < 50
Circuit breaker specification:
Manufacturer Delixi group
Brand Delixi
Model DZ20Y-630/3300-630A
Capacity 630Amps
Voltage
Starting Battery specification:
Battery Voltage 12V
Battery Capacity 200AH
Quantity 2pcs
Battery type lead acid, chargeable
SIVASA Doosan Series
SD500 Technical Data
Control system:
Deepsea 6020
Auto start and stop control
panel
Deepsea 6020 is an auto mains
failure controller for single
generator, it can monitor and
protect the generator working all
the time. it has a LCD display
which clearly shows the status of
the engine. this controller include
seven inputs and six outputs. This
controller can also be programmed
using the frong panel or by using
DSE configuration Suite PC
software.
Parameters:
This controller can provide
Generator frequency, Under/over
speed, Generator volts, Generator
current, Engine oil pressure,
Engine coolant temperature,
Flexible fuel level, Hours run
counter, Battery volts, Fail to
start/stop, Emergency Stop. Failed
to reach loading voltage/frequency,
Charge fail, Loss of magnetic pick-
up signal, Low DC voltage, CAN
diagnostics and CAN fail/error,
Mains volts 3 phase, Mains
frequency, AMF indications
Protection:
♦Low Oil Pressure
♦High water Temperature
♦High voltage and low voltage
♦Overspeed
♦Volt adjuster and frequency
adjuster.
♦Emergency stop
♦Fail to start
Features:
♦Protection: Automatic start/stop,
load transfer and alarming of
generator;
♦ CAN and magnetic pick-up
versions.
♦PC and front panel configurable
♦4 digital inputs and 3 analogue
inputs.
♦6 outputs(4 configurable on
magnetic pick-up, 6 configurable
on Canbus version).
♦3 phase generator and mains
voltage monitoring.
♦remote start on or off load.
♦advanced metering capability.
♦test button.
♦protected solid state outputs.
♦transfer between mains and
generator power.
♦user-friendly set-up and button
layout.
♦multiple engine parameters are
monitored simultaneously.
♦module can be configured to suit
individual applications.
♦IP 65 rating offers advanced
resistance to water ingress when
gasket is fitted.
① Power switch
② Lamp switch
③ Power indicator
④ Operation buttons
⑤ LCD display
Open type
① ② ③ ④
⑤
SIVASA Doosan Series
SD500 Technical Data
⑨ Float battery charger
① Auto Control Panel ④ Base Frame
② Main Ciruit Breaker ⑤ Filter
③ Cooling Radiator ⑥ Starting Motor
⑧ Starting battery
⑩ Flange
2. Optional supply scope:
Supply scope
1.Standard supply scope:
⑦ Exhaust silencer
① ATS
⑩ Trailer &
Silent Canopy ⑥ Synchronization
System
④ External daily fuel tank
⑧ Elec.coolant Heater
③ Auto Fuel Pump
⑨ Oil drain Pump
①
④ ⑤
③
⑤ ABB
Breaker
⑦ Lub oil heater
⑥
② fuel and water
separator
⑤
②