seaport boston common back bay€¦ · attractions and venues such as boston common, the theater...

2
131 Tremont Street is an eight-story mixed-use building situated at a premier location in the center of Downtown Boston. Across the street from Boston Common and situated at the corner of Tremont Street and the Winter Street Pedestrian Concourse, 131 Tremont Street offers exceptional access for commuters. The building is immediately adjacent to Park Street Station (Green/Red Line) and is a short walk to Downtown Crossing (Orange/Red) and Government Center (Green/Blue). 131 Tremont Street is conveniently located just blocks away from many of Boston’s leading cultural attractions and venues such as Boston Common, the Theater District, Downtown Crossing, Financial District and the Freedom Trail. 131 Tremont Street enjoys quick access to numerous nearby eateries like Silvertones, Beantown Pub, Marliave, No. 9 Park, Chipotle, Kensington Station, Dunkin Donuts, Peets at Capital One and Starbucks, among others. LEASE TERM 3 - 5 year term AVAILABLE SPACE 3rd Floor: 4,823 RSF +/- ASKING RATE Negotiable OFFICE SPACE FOR LEASE 4,823 RSF +/- IN CLASS B OFFICE BUILDING FINANCIAL DISTRICT BOSTON COMMON SEAPORT BACK BAY 131 TREMONT

Upload: others

Post on 13-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SEAPORT BOSTON COMMON BACK BAY€¦ · attractions and venues such as Boston Common, the Theater District, Downtown Crossing, Financial District and the Freedom Trail. 131 Tremont

131 Tremont Street is an eight-story mixed-use building situated at a premier location in the center of Downtown Boston. Across the street from Boston Common and situated at the corner of Tremont Street and the Winter Street Pedestrian Concourse, 131 Tremont Street offers exceptional access for commuters. The building is immediately adjacent to Park Street Station (Green/Red Line) and is a short walk to Downtown Crossing (Orange/Red) and Government Center (Green/Blue).

131 Tremont Street is conveniently located just blocks away from many of Boston’s leading cultural attractions and venues such as Boston Common, the Theater District, Downtown Crossing, Financial District and the Freedom Trail. 131 Tremont Street enjoys quick access to numerous nearby eateries like Silvertones, Beantown Pub, Marliave, No. 9 Park, Chipotle, Kensington Station, Dunkin Donuts, Peets at Capital One and Starbucks, among others.

LEASE TERM3 - 5 year term

AVAILABLE SPACE3rd Floor: 4,823 RSF +/-

ASKING RATENegotiable

OFFICE SPACE FOR LEASE4,823 RSF +/- IN CLASS B OFFICE BUILDING

FINANCIAL DISTRICT

BOSTON COMMON

SEAPORT

BACK BAY

131 T R E M O N T

Page 2: SEAPORT BOSTON COMMON BACK BAY€¦ · attractions and venues such as Boston Common, the Theater District, Downtown Crossing, Financial District and the Freedom Trail. 131 Tremont

745 Boylston Street | Boston, MA | (T) 617.375.7900 | (F) 617.536.9566 | BRAdvisors.com© Copyright Boston Realty Advisors. All rights reserved. The information contained here has been obtained through sources deemed reliable but cannot be guaranteed as to its accuracy. Any information of special interest should be obtained through independent verification.

BONNY L. DOORAKIAN Managing Director & Partner 617.850.9655 [email protected]

WILLIAM H. CATLIN, JR. Managing Director & Senior Partner 617.850.9606 [email protected]

ROBERT F. LECLAIR Managing Director & Partner 617.850.9614 [email protected]

FLOOR PLAN

SPECIFICATIONS

Total Size 45,000 SF

Available Space 4,823 RSF +/-

Term 3 - 5 year term

Floors Eight (8)

Elevators Two (2) - Passenger

3RD FLOOR | 4,823 RSF +/-

131T R E M O N T

TREMONT STREET

UP

UP

DN

F.F.L. = 29' - 10 1/2"

TOILET

TOILET

ELEV.

ELEV.

SILL: 2'-2"HEAD: 9' - 8"

SILL: 2'-2"HEAD: 9' - 8"

SILL: 2'-2"HEAD: 9' - 8"

SILL: 2'-2"HEAD: 9' - 8"

SILL: 2'-4"HEAD: 9' - 8"

SILL: 2'-2"HEAD: 9' - 8"

SILL: 2'-2"HEAD: 9' - 8"

SILL: 2'-2"HEAD: 9' - 8"

SILL: 2'-2"HEAD: 9' - 8"

SILL: 2'-2"

HE

AD

: 9' - 8"S

ILL: 2'-2"H

EA

D: 9' - 6"

SILL: 2'-2"

HE

AD

: 9' - 6"S

ILL: 2'-2"H

EA

D: 9' - 6"

SILL: 2'-2"

HE

AD

: 9' - 6"SILL: 2'-2"

HEAD

: 9' - 6"SILL: 2'-2"

HEAD

: 9' - 6"SILL: 2'-2"

HEAD

: 9' - 6"

SILL: 2'-3"HEAD: 9' - 7"

"1-'2 :LLIS"7 - '9 :DAEH

"0-'2 :LLIS"6 - '9 :DAEH

"1-'2 :LLIS"7 - '9 :DAEH

"1-'2 :LLIS"7 - '9 :DAEH

73' - 5"

64' -

3 3

/4"

10' -

3"

5' - 3"64'-8 1/4"

73' -

5"

29' - 10 1/4"15' - 10 1/4"7' - 4"16' - 5"

56' -

7 1

/4"

15' -

11

1/4"

16' -

3"

19' -

5"

24' - 0 3/4"

13' -

9 3

/4"

11' -

2 3

/4"

7' -

11"

43' - 10 1/4"

"2/1 8 - '81

13' -

4 3

/4"

PANEL ROOM

6' - 0 1/2"

UNABLETO

ACCESS

UNABLETO

ACCESS

PARTY WALLTHICKNESS NOTVERIFIED, TYP.

Scale:

Drawn By:

Existing Conditions Surveys Inc.398 Columbus Avenue #334Boston, MA 02116 USA

T 617.247.9161F 617.249.0746E [email protected]

The Most AccurateExisting Conditions Surveys and

As-Built Surveys

www.existingconditions.com

Date:

www.existingconditions.com

All projects are measured using the mostadvanced laser measuring equipment and ourbest standards and practices. All work will befield verified by client prior to design orconstruction or other use, please visitwww.existingconditions.com for terms andconditions of use.

General Notes:

1.It is expressly understood by client that ECS is not anarchitectural or engineering entity. None of the documentsprepared by ECS for client shall have any stamping orcertification of such trade professionals.

2.This is not a structural or MEP analysis or due diligencemodel. Visible and accessible elements are modeled forlocation and size. Further structural or MEP analysis couldbe necessary by others.

3.STANDARD OF PRACTICE. Services performed by ECSunder this Agreement will be conducted in a mannerconsistent with that level of care and skill ordinarilyexercised by members of the profession currently practicingin the same locality under similar conditions. No otherrepresentation, expressed or implied, and no warranty orguarantee is included or intended in this Agreement, or inany report, opinion, document or otherwise.

Laser Scanning Notes:

1.Terrestrial laser scanning equipment utilized by ECS, Inc. isable to achieve levels of accuracy down to ±2mm at 20meters, per FARO, the manufacturer, specifications, seewww.faro.com

2.Laser scanning equipment uses light waves to measuredistances, unforeseen site conditions such as dust,moisture, vibration, surface reflectivity, lighting conditions,temperature, humidity, ferromagnetic materials, buildingconfiguration etc. may impact registration between scanlocations.

3.Accuracy over long distances can be improved if the clientprovides survey benchmarks prior to scanning in order toreference the laser scan data into a coordinate system.

4.The Revit file contains the most complete alignment of pointcloud data. All laser scanning by default is in a localizedcoordinate system. Laser scans completed on multiple daysmay be tied into previous laser scans by use of site specificfeatures and targets. Final point cloud adjustments aremade in Revit for a final verification.

TM

REV03062017

1/4" = 1'-0"

Boston, MA

Existing ThirdFloor Plan

EX04 ECS

09/07/18

131 Tremont St.

Revision Schedule

RevisionNumber

RevisionDescription

RevisionDate