Section - M

Componentsfor gas

installation

2

M

EXAMPLE OF APPLICATION

COMPONENTS FOR GAS INSTALLATION

1 Gas leak detector unit.2 Remote gas leak detector.3 Central unit.4 Remote gas leak detector.5 Normally closed gas solenoid valve with

manual resetting.

6 Vibration-damping expansion joint.7 Gas pressure gauge.8 Gas filter.9 Gas stabilizer.

3344

22

11

99

8877

66

55

3

M

COMPONENTS FOR GAS INSTALLATION

FLOW CHART

NOTES :

MSVO/MSVG : NORMALLY OPEN gas solenoid valve with manual resetting EVO/EV : NORMALLY CLOSED gas solenoid valve with MANUAL RESETTING

A) FAULT : function of the electronic circuit which, in case of critical fault to the sensor or main components, is actuated givingluminous signal (yellow LED) and commands closing of solenoid valve.

B) SELF-DIAGNOSTICS : function of the electronic circuit continuously monitoring correct operation of the entire equipment(including remote sensor); in case of fault, it gives a luminous signal and commands closing ofsolenoid valve.

GS1 GS3 UR GSA3 URA CIVIC2 CIVIC6 CIVR

Protection class IP42 IP42 IP42 IP42 IP42 IP55 IP20 IP54

Installation Wall Wall Wall Wall Wall Wall On Omega Wallmounted mounted mounted mounted mounted mounted guides mounted

35 mm

4

M

GAS LEAK DETECTOR DEVICES

COMPONENTS FOR GAS INSTALLATION

GAS SENTINEL.Electronic gas leak detector unit (sensor inside the unit) with acoustic and luminous alarm, tobe connected to one or more normally closed gas solenoid valves with manualresetting (EVO, EV) or normally open (MSVO, MSVG). Power consumption: 4 W. Relay contact load capacity: 550 VA. Calibration in the range 5-20% LIE.Operating temperature: - 10°C / + 50°C. Spray- and dust-proof transformer and relays: IP67.Protection class of the detector unit: IP42. Thermal compensation for the sensor.Fault: when a critical fault occurs on the sensor or main components, a luminous signal is given.

IMQ approved (only GS1 for natural gas).According to EEC 89/336, EEC 73/23, Min. Circular 27/7/1994 N° 161892.

GS1

Type Part number Description Power supply Box QtyGS1 0940200 Natural gas 230V 1GS1 0945200 LPG 230V 1

GAS SENTINEL.Electronic gas leak detector unit (sensor inside the unit) with acoustic and luminous alarm, tobe connected to one or more normally closed gas solenoid valves (EVO, EV) ornormally open (MSVO, MSVG). The gas detector can function as a single unit or with 2remote units UR (2 units for natural gas or 2 units for LGP).Other technical characteristics like GS1.

According to EEC 89/336, EEC 73/23, Min. Circular 27/7/1994 N° 161892.

GS3

Type Part number Description Power supply Box QtyGS3 0940300 Natural gas 230V 1GS3 0945300 LPG 230V 1

GAS SENTINEL.Gas leak detector unit to be connected to unit GS3. Power supply taken from unit GS3: 12Vcc.Calibration in the range; 5-20% LIE. Power consumption: 0.5 W.Operating temperature: - 10°C / + 50°C. Protection class: IP42.

According to EEC 89/336, EEC 73/23.

UR

Type Part number Description Box QtyUR 0940350 Natural gas 1UR 0945350 LPG 1

Basic system with normally open solenoid valve or normally closedand system with central unit with n° 2 remote units

GS1

MSVOMSVGEVOEV

MSVOMSVGEVOEV

UR UR

GS3

5

M

COMPONENTS FOR GAS INSTALLATION

GAS LEAK DETECTOR DEVICES

GAS SENTINEL.Electronic gas leak detector unit (sensor inside the unit) with acoustic and luminous alarm, plusrelay for commanding one or more gas solenoid valves normally closed (EVO, EV) ornormally open (MSVO, MSVG). The gas detector can function as a single unit or with 2remote units URA or CIVR. Power consumption: 4 W + 0.5 W for URA, CIVR.Calibration in the range: 5-20% LIE. Relay contact load capacity: 550 VA.Operating temperature: - 10°C / + 50°C. Spray- and dust-proof transformer and relays: IP67.System reset button. Protection class: IP42. Thermal compensation for the sensor.

GENERAL SAFETY GUARANTEEThe GSA units are provided with an electronic self-diagnostics circuit continuously monitoringthe unit for correct operation. Any fault is warned through an acoustic and light (yellow LED)signal while the gas line solenoid valve is closed automatically.

According to EEC 89/336, EEC 73/23.

GSA3

Type Part number Description Power supply Box QtyGSA3 0940400 Natural gas 230V 1GSA3 0945400 LPG 230V 1

GAS SENTINEL.Gas leak detector unit for connection to units GSA3, CIVIC2, CIVIC6.Power supply from unit GSA3: 12 Vcc. Power consumption: 0.5 W.Calibration in the range: 5-20% LIE. Operating temperature: - 10°C / + 50°C.Protection class: IP42. Thermal compensation for the sensor.

GENERAL SAFETY GUARANTEEThe remote URA units are provided with an electronic self-diagnostics circuit which, wheninterfaced with detector GSA3, CIVIC2 and CIVIC6, continuously monitors the unit for correctoperation. Any fault is warned through an acoustic and light (yellow LED) signal while gas linesolenoid valve is closed automatically.

According to EEC 89/336, EEC 73/23.

URA

Type Part number Description Box QtyURA 0940450 Natural gas 1URA 0945450 LPG 1

Basic system with normally open solenoid valve or closed and systemwith central unit with n° 2 remote units

GSA3MSVOMSVG

EVOEV

EVOEV

MSVOMSVG

CIVR URA

GSA3

6

M

GAS LEAK DETECTOR DEVICES

COMPONENTS FOR GAS INSTALLATION

Central unit for installation in zones with explosion risk (e.g. boilers > 35 kw), to be connect-ed to CIVIC2, CIVIC6 or GSA3 for detecting presence of gas. The sensor, housed in an ex-proof metal case, with sintered drain, allows installation of remote unit CIVR in zones clas-sified as hazardous (CEI64/2). Power supply from CIVIC2 or CIVIC6 or GSA3 (12V).Protection class (unit): IP54. Unit with intrinsic safety. Calibration in the range: 5/20% LIE.Operating temperature: - 10°C / + 50°C. Humidity: 0 - 80% (appreciable variation of calibrationcould occur at higher percentage humidity). Temperature class T3 (max. surface temperature less than 200°C).

According to EEC 89/336, EEC 73/23.

CIVR

Type Part number Description Box QtyCIVR 0940550 Natural gas 1CIVR 0945550 LPG 1

Central unit for installation in zones with explosion risk (e.g. boilers > 35 kw) with alarmand command for solenoid valve normally closed (EVO, EV) or normally open (MSVOor MSVG) and remote alarm (siren, telephone dialler, etc.).Provision for connecting up to 2 remote sensors CIVR or URA for natural gas or LPG, also ofdifferent type (CIVR for natural gas and LPG or URA for natural gas and LPG).Relay contact load capacity: 550 VA. Operating temperature: - 10°C / + 50°C.Spray- and dust-proof transformer and relays: IP67. Protection class (unit): IP55.Temperature class T3 (max. surface temperature less than 200°C).Unit with intrinsic safety. Buzzer 85 db (A) at 1 m.

Indicators :

- Green POWER LED signals correct power supply and running.- Red GAS LED + buzzer signals, for each remote unit CIVR connected, a gas leak

or fault on the electronic circuits (self-diagnostics function).

According to EEC 73/23, EEC 89/336.

CIVIC2

Type Part number Power supply Box QtyCIVIC2 0940502 230V 1

Central unit for installation in electrical cabinet (omega guide DIN EN50022 35 mm), withalarm and command for solenoid valve normally closed (EVO, EV) or normally open(MSVO or MSVG) and remote alarm (siren, telephone dialler, etc.).Provision for connecting up to 6 remote sensors CIVR or URA for natural gas or LPG, also ofdifferent type (CIVR for natural gas and LPG or URA for natural gas and LPG).Relay contact load capacity: 550 VA. Operating temperature: - 10°C / + 50°C.Spray- and dust-proof transformer and relays: IP67. Protection class (unit): IP20.System reset button. Buzzer 85 db (A) at 1 m.

Indicators :

- Green POWER LED signals correct power supply and running.- Red GAS LED + buzzer signals, for each remote unit CIVR connected, a gas leak

or fault on the electronic circuits (self-diagnostics function).

According to EEC 73/23, EEC 89/336.

CIVIC6

Type Part number Power supply Box QtyCIVIC6 0940506 230V 1

7

M

COMPONENTS FOR GAS INSTALLATION

GAS LEAK DETECTOR DEVICES

Self-diagnostic systems for installation in zones with explosion risk(e.g. Boiler > 35 kw) and domestic environments

MSVOMSVGEVOEV

MSVOMSVGEVOEV

CIVIC2

CIVR CIVRURA

CIVRURA

CIVIC6

FUNCTION OF SELF-DIAGNOSTICS SAFETY

The gas leak detectors manufactured by INTERMES (GSA3, CIVIC2, CIVIC6 and CIVR) are provided with electronicSELF-DIAGNOSTICS safety function: an electronic circuit continuously monitoring the entire gas detection system forcorrect operation (central units GSA3, CIVIC2 or CIVIC 6 and remote units URA and CIVR plus electrical connectionsbetween them).

When a fault occurs, the yellow FAULT LED lights up on the remote unit (CIVR or URA), while an acoustic and optical sig-nal is given on the central unit as well as command to close the solenoid valve (EVO and EV).

8

M

DIELECTRIC UNIONS

COMPONENTS FOR GAS INSTALLATION

Type Part number Size body Box QtyBS3015 24331 1/2” MF 10BS3015 24332 3/4” MF 10

Dielectric joints for joining pipes of different metals thus eliminating corrosion risks due to straycurrents or electrolytic phenomena. For use with water, combustible gases, petrol, kerosene,mineral and vegetable oils. Galvanized steel body, female connection and brass maleconnection. Max. pressure: 12 bar. Max. temperature: 110°C at 10 bar.Electrical insulation up to 600 V with dry piping. Exclusive insulator, Watts GA1425.

According to UNI-CIG 9860.

BS3015

Type Part number Size body Box QtyBS3003 EDP0821309 1/2” FF 10BS3003 EDP0821310 3/4” FF 10BS3003 EDP0821723 1” FF 10BS3003 EDP0821722 1-1/4” FF 10BS3003 EDP0821340 1-1/2” FF 10BS3003 EDP0821350 2” 10

Dielectric unions like BS3015 but with female connections.

According to UNI-CIG 9860.

BS3003

Type Part number Size body Box QtyBS3004 EDP0821737 1/2”F 10BS3004 EDP0821733 3/4”F 10BS3004 EDP0821731 1”F 10BS3004 EDP0821738 1-1/4” 10BS3004 EDP0821739 1-1/2” 10BS3004 EDP0821746 2” 10

Dielectric joints for joining steel/steel pipes. All galvanized steel body.Coupling between the two joint parts is female connections.

According to UNI-CIG 9860.

BS3004

Type Part number Size body Box QtyBS3001 EDP0821600 15mm x 1/2” F 10BS3001 EDP0821604 16mm x 3/4” F 10BS3001 EDP0821605 22mm x 3/4” F 10BS3001 EDP0821610 28mm x 1” F 10BS3001 EDP0821615 32mm x 1-1/4” F 10BS3001 EDP0821617 35mm x 1-1/2” F 10

Dielectric unions like BS3015 but with brass weld and female connections.

According to UNI-CIG 9860.

BS3001

GAS GOVERNOR AND GAS LINE FILTER

9

M

COMPONENTS FOR GAS INSTALLATION

GAS SOLENOID VALVES

A range of Gas Solenoid valves, available as normally open and normally closed with screwedends 1/2” to 2” BSP Female and flanged ends 65mm to 150mm. Coil voltages 12vdc, 24vac,24vdc and 230vac. Suitable for domestic gas, LPG and methane.

Further details available upon request.

A range of Gas Governors with and without filters and Gas Line Filter for wall boilers. Screwedends 1/2” to 2” BSP Female and flanged ends 65mm to 150mm dependant on specification.Suitable for domestic gas, LPG and methane.

Further details available upon request.

10

M

CHAPTER M

OVERALL DIMENSIONS

GS1 - GS3 - GSA3 UR - URA

CIVIC2 CIVIC6

11

M

OVERALL DIMENSIONS

CHAPTER M

CIVR

R L1/2” 533/4” 571” 651.1/4” 701.1/2” 702” 79

R G L1/2” 15 483/4” 16 543/4” 22 541” 28 641-1/4” 32 761-1/2” 35 76

BS3015

R G L1/2” 1/2” 553/4” 3/4” 61

BS3003 / BS3004 BS3001

Watts Industries UK Ltd

Grosvenor Business Park, Evesham, Worcestershire, WR11 1GA, England

Phone +44 (0) 1386 446997 - Fax +44 (0) 1386 41923