4G
79 8079
FP FD FL FC
FP 874 FD 874 FL 874 FR 874 FM 874 FX 874 FZ 874
18 9 20 21
22 33 34
General Catalog 2013-20144/127
Rope safety switches without reset for simple stop
CONTACT BLOCKS 1NO+1NC
slow action 2NC
slow action1NO+2NC slow action
3NC slow action
2NO+1NC slow action
1NO+1NC slow action
2NC slow action
CONDUIT ENTRIES
Threaded conduit entries(standard)
With cable gland assembled
With M12 metal connector assembled and wired
With M12 plastic connector assembled and wired
Selection diagram
ACTUATORS ACTUATORS
4G
FD 1879-E7GM2K50
FC 3379-E7GM1K22
FD 874-E7M2K50
4/128General Catalog 2013-2014
Contact blocks
18 1NO+1NC, slow action9 2NC, slow action
20 1NO+2NC, slow action21 3NC, slow action22 2NO+1NC, slow action33 1NO+1NC, slow action 34 2NC, slow action
Actuating head
79 longitudinal head80 transversal head (only for FD-FL housing)
Threaded conduit entry
PG 13,5 (standard)
M2 M20x1,5
Contacts type
silver contacts (standard)
G silver contacts gold plated 1 µm
Housing
FD metal housing, one conduit entryFL metal housing, three conduit entriesFP polymer housing, one conduit entry
Contacts type
silver contacts (standard)
G silver contacts gold plated 1 µm
Contact blocks
33 1NO+1NC, slow action
34 2NC, slow action
Threaded conduit entry
PG 11 (standard)
M1 M16x1,5
Housing
FC metal housing, one conduit entry
Actuating head
79 longitudinal head
80 transversal head
Contact blocks
8 1NC, slow action Threaded conduit entry
PG 13,5 (standard)
A PG 11 (only for FR-FX housing)
M1 M16x1,5 (only for FR-FX housing)
M2 M20x1,5
Housing
FD metal housing, one conduit entryFL metal housing, three conduit entriesFP polymer housing, one conduit entryFR polymer housing, one conduit entryFM metal housing, one conduit entryFX polymer housing, two conduit entriesFZ metal housing, two conduit entries
Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office.
article options
article options
article options
Actuating force
standardE7 initial 20 N...final 40 N (only for head 79)
E9 initial 13 N...final 75 N (only for head 80)
Actuating force
standardE7 initial 20 N...final 40 N (only for head 79)
E9 initial 13 N...final 75 N (only for head 80)
Actuating force
standardE7 initial 20 N...final 40 N
Preinstalled cable gland
no cable gland (standard)
K22 with assembled cable gland suitable for Ø 5 to Ø 10 mm cables range
K26 with assembled cable gland suitable for Ø 3 to Ø 7 mm cables range
Preinstalled cable gland or connectors
no cable gland or connector (standard)
K21 with assembled cable gland suitable for Ø 6 to Ø 12 mm cables range
... ........................
K50 with assembled 5 poles M12 metal connector
... ........................For the complete list of all combinations, please contact our technical office.
Preinstalled cable gland or connectors
no cable gland or connector (standard)
K21 with assembled cable gland suitable for Ø 6 to Ø 12 mm cables range
... ........................
K50 with assembled 5 poles M12 metal connector
... ........................For the complete list of all combinations, please contact our technical office.
4G
Technical data
General Catalog 2013-20144/129
Cross section of the conductors (flexible copper wire)Contact blocks 20, 21, 22, 33, 34: min. 1 x 0,34 mm2 (1 x AWG 22) max. 2 x 1,5 mm2 (2 x AWG 16)Contact blocks 18, 8, 9: min. 1 x 0,5 mm2 (1 x AWG 20) max. 2 x 2,5 mm2 (2 x AWG 14)
Electrical data Utilization categories
Alternate current: AC15 (50...60 Hz)Ue (V) 250 400 500Ie (A) 6 4 1Direct current: DC13Ue (V) 24 125 250Ie (A) 6 1,1 0,4
Alternate current: AC15 (50...60 Hz)Ue (V) 24 120 250Ie (A) 4 4 4Direct current: DC13Ue (V) 24 125 250Ie (A) 4 1,1 0,4
Thermal current (Ith): 4 ARated insulation voltage (Ui): 250 Vac 300 VdcProtection against short circuits: fuse 4 A 500 V type gGPollution degrees: 3
with
4 o
r 5
pole
sM
12 c
onne
ctor
Thermal current (Ith): 2 ARated insulation voltage (Ui): 30 Vac 36 VdcProtection against short circuits: fuse 2 A 500 V type gGPollution degrees: 3w
ith 8
pol
esM
12 c
onne
ctor
Alternate current: AC15 (50...60 Hz)Ue (V) 24 Ie (A) 2 Direct current: DC13Ue (V) 24 Ie (A) 2
with
out
conn
ecto
r
HousingHousing type FP, FR and FX made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic Housing type FD, FL, FC, FM and FZ made of metal, coated with baked epoxy powder.FD, FP, FC, FR and FM series one conduit entryFX and FZ series two conduit entriesFL series three conduit entries Protection degree: IP67 according to EN 60529 with cable gland having equal or higher protection degree
General dataFor safety applications up to SIL 3 / PL eSafety parameters: see page 7/34Ambient temperature: from -25°C to +80°CVersion for operation in ambient temperature from -40°C to +80° C on request
Max actuation frequency: 1 operation cycles / 6 sMechanical endurance: 1 million of operations cycles1
Max actuating speed: 0,5 m/s Min. actuating speed: 1 mm/sDriving torque for installation: see pages 7/1-7/12(1) One operation cycle means two movements, one to close and one to open contacts, as foreseen by EN 60947-5-1 standard..
Main data
Metal or polymer housing, from one to three conduit entries
Protection degree IP67
7 contact blocks available
Transversal head or longitudinal head versions
M12 assembled connector versions
Silver contacts gold plated versions
Several accessories available
Rope safety switches without reset for simple stop
Markings and quality marks:
Approval IMQ: EG605 (FD-FL-FC series) EG606 (FP series) EG610 (FR-FX-FK series) EG609 (FM-FZ series)Approval UL: E131787Approval CCC: 2007010305230000 (FD-FL-FC series) 2007010305230014 (FP series) 2007010305230013 (FR-FX-FK series) 2007010305229998 (FM-FZ series)Approval EZU: 1010151Approval GOST: POCC IT.AB24.B04512
In conformity with requirements requested by: Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC and Electromagnetic Compatibility 2004/108/EC.Positive contact opening in conformity with standards: IEC 60947-5-1, EN 60947-5-1, VDE 0660-206.
In conformity with standards:IEC 60947-5-1, EN 60947-5-1, EN 60947-1, IEC 60204-1, EN 60204-1, EN 1088, EN ISO 12100-1, EN ISO 12100-2, IEC 60529, EN 60529, NFC 63-140, VDE 0660-200, VDE 0113.Approvals:IEC 60947-5-1, UL 508, GB14048.5-2001.
If not expressly indicated in this chapter, for the right installation and the correct utilization of all articles see requirements indicated from page 7/1 to page 7/12.
Thermal current (Ith): 10 ARated insulation voltage (Ui): 500 Vac 600 Vdc 400 Vac 500 Vdc (contact blocks 20, 21, 22, 33, 34) Rated impulse withstand voltage (Uimp): 6 kV 4 kV (contact blocks 20, 21, 22, 33, 34)Conditional shot circuit current: 1000 A according to EN 60947-5-1Protection against short circuits: fuse 10 A 500 V type aMPollution degree: 3
4G
4/130General Catalog 2013-2014
These rope operated safety switches are installed on machines or conveyor belts, to activate the simple stop of the machine on every hand intervention on the rope, from any point.Provided with self-control function, they constantly check their correct working operation, signalling with the opening of the contacts an eventual loosening or breaking of the rope.
Please contact our technical service for the list of approved products.
Please contact our technical service for the list of approved products.
Data type approved by ULRated insulation voltage (Ui): 500 Vac 400 Vac (for contact blocks 20, 21, 22, 33, 34) Thermal current (Ith): 10 AProtection against short circuits: fuse 10 A 500 V type aMRated impulse withstand voltage (Uimp): 6 kV 4 kV (for contact blocks 20, 21, 22, 33, 34)Protection degree: IP67MV terminals (screw clamps)Pollution degrees 3Utilization category: AC15Operation voltage (Ue): 400 Vac (50 Hz)Operation current (Ie): 3 AForms of the contact element: Zb, Y+Y, Y+Y+X, Y+Y+Y, Y+X+XPositive opening of contacts on contact block 18, 8, 9, 20, 21, 22, 33, 34
In conformity with standards: EN 60947-1, EN 60947-5-1+ A1:2009, fundamental requirements of the Low Voltage Directive 2006/95/CE.
Description
Rotating headsRemoving the four fastening screws, in all switches, it is possible to rotate the head in 90° steps.
The switches (head 79 and 80) are provided with a green ring that shows the area of the correct stretching of the rope. The installer has only to stretch the rope until the black indicator will be in the middle of the green area. If a traction (or loosening ) of the rope it is high enough to permit the black indicator to go outside
the correct stretching area, there will be the opening of the safety contacts.
Rope regulation point indicator
Area of correct rope stretching
Stretching indicator
Data type approved by IMQ, CCC and EZUUtilization categories Q300 (69 VA, 125-250 Vdc) A600 (720 VA, 120-600 Vac)Data of the housing type 1, 4X “indoor use only”, 12, 13For all contact blocks use 60 or 75 °C copper (Cu) conductor and wire size No. 12-14 AWG. Terminal tightening torque of 7,1 lb in (0.8 Nm).
In conformity with standard: UL 508
18 L
9 L
20 L
21 L
22 L
33 L
34 L
18 L
9 L
20 L
21 L
22 L
33 L
34 L
4G
2828
4030
39
16
16
72
138
606305.3
5.3x
7.3
60
15
303040
726.
5
138.
5
28
38
28
16
5.3
5.3x
7.3
22
32
20
84
16
15
30
30
40
38
5.3
606.
5
5.3x7.3
28
28
56
57
18
40
33
7212
9
6
14.5
14.5
5.3x6.3
57
18
406
56 33
2232
2084
14.5
14.5
89
5.2x6.2
28
28
40
28.5
4472
116
14.5
14.5
33
5.5
40
84
2232
30
20 14.5
28.5
3314.5
5.544
76
23-24
11-120 8.57.5
2 8S
41.5
7
FP 1879 1NO+1NC
FP 979 2NC
FP 2079 1NO+2NC
FP 2179 3NC
FP 2279 2NO+1NC
FP 3379 1NO+1NC
FP 3479 2NC
FD 1879 1NO+1NC
FD 979 2NC
FD 2079 1NO+2NC
FD 2179 3NC
FD 2279 2NO+1NC
FD 3379 1NO+1NC
FD 3479 2NC
FD 1880 1NO+1NC
FD 980 2NC
FD 2080 1NO+2NC
FD 2180 3NC
FD 2280 2NO+1NC
FD 3380 1NO+1NC
FD 3480 2NC
FL 1879 1NO+1NC
FL 979 2NC
FL 2079 1NO+2NC
FL 2179 3NC
FL 2279 2NO+1NC
FL 3379 1NO+1NC
FL 3479 2NC
FC 3379 1NO+1NC
FC 3479 2NC
FC 3380 1NO+1NC
FC 3480 2NC
FL 1880 1NO+1NC
FL 980 2NC
FL 2080 1NO+2NC
FL 2180 3NC
FL 2280 2NO+1NC
FL 3380 1NO+1NC
FL 3480 2NC
Min. force
Travel diagrams
Min. force
Travel diagrams
Accessories See page 6/1
General Catalog 2013-20144/131
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 1
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 1
Initial 147 N...Final 235 N (250 N )
page 4/132 - group 2
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 1
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 1
Initial 147 N...Final 235 N (250 N )
page 4/132 - group 2
Initial 147 N...Final 235 N (250 N )
page 4/132 - group 2
Dimensional drawings
NO opening
Max travel
NC closing Positive opening travel
Closed contact
Open contact
Ideal rope tension pointIMPORTANT: In safety applications it is necessary to activate the switch at least up to the positive opening point indicated in the diagrams with the symbol . Operate the switch at least with the positive opening force, indicated between brackets, below each article, next the value of minimum force.
How to read travel diagrams All measures in the diagrams are in mm
Example diagram
All measures in the drawings are in mm
Contacts type:
L = slow action
Contact blocks
Contact blocks
Min. force
Travel diagrams
Min. force
Travel diagrams
Rope safety switches without reset for simple stop
4G
8 L
8 L
2022 24.2
51.5
30.8 30.8
14.2
38.8
15.3
108.
6
12.2
3 4.2x7.2
3
30.8 31.5
24.22022
12.2
14.2
54.4
38.8
15.3
111.
5
4.2x7.2
18.5
45
20224042
4
3
58
5611 24.2
14.231.7
46.1
15.3
12.2
3
50
24.2
31.5
18.5
45
14.2
12.2
38.8
102.
115
.3
4.2x7.2
20224042
15.3
18.5332
.360
6
30116.
6
40
5.3
5.3x7.3
16
16
3039
32.1
30
15.3
116.
9
18.53
40 15.2
16
30
38
6.5
60
5.3
5.3x7.3
18.5315
.3
7
40
5732
.1
107
18
56
5.3x6.3
14.5
14.5
33
6
FR 874 1NC FM 874 1NC FX 874 1NC
181NO+1NC
0 8.57
7.4
1.5
1.1 8S
4 0 16133.5
4 12.6 14S
8
81NC
0
6.3
8.51 8
S
4
92NC
0 8.5
7.21.4
8
S
4 0
133.5
14.5
S
8 16
201NO+2NC
0 8.571.5
7.41.1
8
S
4 0 16
133.5
3.8 12.614
S
8
213NC
0 8.5
71.5
8
S
4 0 163.5 12.614
S
8
222NO+1NC
0 8.571.5
7.41.1
8
S
4 0
133.5
3.8 12.614
S
8 16
331NC+1NO
0 8.57
7.4
1.5
1.1 8S
4 0 16
133.5
3.8 12.614
S
8
342NC
0 8.5
71.5
8
S
4 0 163.8 12.614
S
8
FZ 874 1NC
FP 874 1NC FD 874 1NC FL 874 1NC
4/132General Catalog 2013-2014
Travel diagrams table
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 3
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 3
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 3
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 3
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 3
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 3
Initial 63 N...Final 83 N (90 N )
page 4/132 - group 3
Contacts type:
L = slow action
Contact blocks
Contact blocks
Min. force
Travel diagrams
Min. force
Travel diagrams
Contact blocksGroup 1 Group 2 Group 3
In the rest position (with rope correctly tightened) the two contacts of contact block 8 are both closed and are activated respectively by actuating or loosening the rope. In order to use this contact block for safety applications is necessary to connect the two contacts in series. For this reason in wiring diagrams the contact block 8 is indicated as 1NC, whereas in travel dia-grams are indicated both contacts.
Items with code on the green background are available in stock
4G
50 m MAX
3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m
FD
188
0F
D 1
880
FD
188
0
70 m MAX
3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m
FD
188
0
FD
188
0
16 m MAX
35 m MAX
3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m 3 ÷ 5 m
FD 1879
18 m MAX
2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m
FD 1879
24 m MAX
2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m
FD 1879
6 m MAX
FD 1879
12 m MAX
2 ÷ 3 m 2 ÷ 3 m 2 ÷ 3 m
FD 1879
FD 1880
5 m max 5 m max
FD 1879
FD 874
3 m max 3 m max
General Catalog 2013-20144/133
Application examples and max rope length for switches with longitudinal heads
VF AF-ME78
Application examples and max rope length for switches with transversal heads
VF AF-TR5 VF AF-MR5
VF AF-MR5VF AF-TR5
VF AF-TR5 VF AF-MR5
VF AF-MR5VF AF-TR5
VF AF-ME80
VF AF-TR5 VF AF-MR5
VF AF-MR5VF AF-TR5
VF AF-TR5 VF AF-MR5
VF AF-MR5VF AF-TR5
Example A
Example B
Example C
Example D
Example F
Example G
Example H
Example I
Example J
PulleyVF AF-TR8
Pulley
Example E
VF AF-TR8
VF AF-MR5
VF AF-MR5
Rope safety switches without reset for simple stop
4G
0
5
10
15
20
25
30
0 10 20 30 40 50 60 70 80 90 100
0
10
20
30
40
50
60
70
80
0 10 20 30 40 50 60 70 80 90 100
4/134General Catalog 2013-2014
Max rope length
Max rope length for switches with longitudinal heads
Max
leng
ths
of t
he r
ope
(m)
Thermal differential (°C)
Max rope length for switches with transversal heads
Max
leng
ths
of t
he r
ope
(m)
Thermal differential (°C)
Important: The above data are guaranteed only using original rope and accessories. See page 4/135.
example Aexample B
example C-Eexample D
example Fexample G
example H-Jexample I
In the diagram, the suggested max. rope lengths with regard to changes of temperature (thermal differential) to which the switch is expected to be exposed in the working area are indicated.For instance, for an example C installation which expects a thermal differential of 30°C, a max rope length of 10 meters is suggested.
Adjusting of intervention point
For switches with head 79 and 80: Stretch the rope connected to the switch, until the end of the indicator (1)
reaches about the middle of the green ring (2).
For switches with head 74: stretch the rope connected to the switch till the thimble will be at about 4 mm from
the head.