SM 1D2.0004 1000 Technology Drive, Pittsburgh, PA 15219
645 Russell Street, Batesburg, SC 29006
Serial Link Isolator Units
Notice This module is one of a series of modules that describe the
components of the MicroLok II system.
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 ii
Proprietary Notice This document and the information contained therein are confidential – the disclosure or other communication, copying, reproduction and any use whatsoever is forbidden without the written authorization of Hitachi Rail STS USA, Inc.
Important Notice STS USA constantly strives to improve our products and keep our customers apprised of changes in technology. Following the recommendations contained in the attached service manual will provide our customers with optimum operational reliability. The data contained herein purports solely to describe the product, and does not create any warranties.
Within the scope of the attached manual, it is impossible to take into account every eventuality that may arise with technical equipment in service. Please consult an STS USA local sales representative in the event of any irregularities with our product.
STS USA expressly disclaims liability resulting from any improper handling or use of our equipment, even if these instructions contain no specific indication in this respect. We strongly recommend that only approved STS USA spare parts are used as replacements.
© Property of Hitachi Rail STS USA, Inc., 2014 all rights reserved 1000 Technology Drive, Pittsburgh, PA USA 15219-3120
645 Russell Street, Batesburg, SC 29006 sts.hitachirail.com
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 iii
Revision History REV ISSUE DATE REVISION DESCRIPTION
1 April 2014 Initial release
2 March 2019 Hitachi Rail STS Branding
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 iv
Table of Contents 1. SERIAL LINK ISOLATOR UNITS ..................................................................................................... 1-1
1.1. General Information .................................................................................................................. 1-1 1.2. Operation .................................................................................................................................. 1-2
1.2.1. RS-232/423-Compatible Serial Isolator ........................................................................ 1-3 1.2.2. ATCS Radio-Compatible Serial Isolators ..................................................................... 1-3 1.2.3. Triple Isolation Serial Isolator ....................................................................................... 1-3
1.3. Rack Mount Panel .................................................................................................................... 1-4 1.4. Adapter PCB ............................................................................................................................. 1-5 1.5. User Interface ........................................................................................................................... 1-5 1.6. Serial Isolator Unit Specifications ............................................................................................. 1-6 1.7. PCB Addressing and Communication ...................................................................................... 1-7 1.8. I/O Interface .............................................................................................................................. 1-7 1.9. System Applications ............................................................................................................... 1-16 1.10. Configuration Options ............................................................................................................. 1-21
2. TECHNICAL SUPPORT .................................................................................................................... 2-1
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 v
List of Figures Figure 1-1. RS-232/423 Serial Isolator N16401101 Detail ....................................................................... 1-1 Figure 1-2. ATCS Radio Serial Isolators N16404701 & N16404702 Detail .............................................. 1-2 Figure 1-3. RS-232/423 Triple Isolated Serial Isolator N16401103 Detail ................................................ 1-2 Figure 1-4. Triple Isolation Serial Isolator Connector Label ...................................................................... 1-4 Figure 1-5. Rack-Mount Panel (M16404901) for ATCS Radio Serial Isolators ........................................ 1-4 Figure 1-6. Adapter PCB (N39902601) for the ATCS Radio Serial Isolator RS-422
to EIA/TIA-232 (DCE) .......................................................................................................... 1-5 Figure 1-7. RS-232/423 Serial Isolator Typical Wiring Diagram ............................................................... 1-8 Figure 1-8. I-LOK to Serial Isolator Cable N16919401 ........................................................................... 1-10 Figure 1-9. E-LOK to Serial Isolator Cable N16919601 .......................................................................... 1-10 Figure 1-10. MLK II Port 3 via CPU Cable N16915601 to Serial Isolator Cable N16919701 ................. 1-11 Figure 1-11. GEN II Port 3 via CPU Cable N16916801 to Serial Isolator Cable N32500301 ................ 1-12 Figure 1-12. Serial Isolator to Rugged Server RS400 Cable N16919501 .............................................. 1-12 Figure 1-13. GEN II Ports 3 and 4 to Isolator Serial Isolators Cable N16921701 .................................. 1-13 Figure 1-14. Serial Isolator ATCS DB25F to Radio DB25M Cable N16917201 ..................................... 1-14 Figure 1-15. Serial Isolator ATCS DB25F to Radio ATCS MIL-SPEC Cable N16919901 ..................... 1-15 Figure 1-16. Serial Isolator DB25M to Radio WCM RJ-45 Cable N16920701, 02, and 03 ................... 1-16 Figure 1-17. Typical Microlok II Master or Slave to RFL Serial Modem Interface RS-232
Port 4 with Serial Isolator (Microlok or Genisys Protocol) ................................................. 1-17 Figure 1-18. Typical Microlok II Master or Slave to RFL Serial Modem Interface RS-232
Port 3 with Serial Isolator (Microlok or Genisys Protocol) ................................................. 1-17 Figure 1-19. Typical Microlok II Master or Slave Serial Interface RS-232 Port 4 with
Serial Isolator (Microlok or Genisys Protocol) ................................................................... 1-18 Figure 1-20. Typical Microlok II Master to Microlok II Slave Serial Interface RS-423
Port 3 with Serial Isolator (Microlok Protocol) ................................................................... 1-19 Figure 1-21. Typical ATCS WIU Protocol Radio Connection .................................................................. 1-20 Figure 1-22. Microlok II Vital and Non-Vital Serial Communications ...................................................... 1-21
List of Tables Table 1-1. Serial Link Isolator Units .......................................................................................................... 1-1 Table 1-2. RS-232/423 Serial Isolator Specifications ............................................................................... 1-6 Table 1-3. ATCS Radio-Compatible Serial Isolator Specifications ........................................................... 1-6 Table 1-4. RS-232 Triple Isolator Specifications....................................................................................... 1-6 Table 1-5. Serial Link Isolator Unit Connector Cables .............................................................................. 1-9
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 vi
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-1
1. SERIAL LINK ISOLATOR UNITS
1.1. General Information
Serial Link Isolator Units are used for data channel protection. See Table 1-1for the part numbers and application of the Serial Link Isolators.
Table 1-1. Serial Link Isolator Units
STS USA Part No. Application Figure Reference
N16401101 RS-232/423 Serial Isolator Figure 1-1
N16404701 ATCS Radio Serial Isolator: RS-422 to EIA/TIA-232 (DCE) Figure 1-2
N16404702 ATCS Radio Serial Isolator: EIA/TIA-485 to EIA/TIA-232 (DCE) Figure 1-2
N16401103 RS-232/423 Triple Isolated Serial Isolator Figure 1-3
UNION SWITCH & SIGNAL645 RUSSELL ST.BATESBURG, SC 29006
MICROTRAX IN
POWER
MICROLOK IN
(FEMALE CONN)RECEPT.
BATT -
BATT+
(MALE CONN)PLUG
1D2.
0004
.040
1.00
BATTERY TEMINALS
SERIAL PORT CONNECTORS
Figure 1-1. RS-232/423 Serial Isolator N16401101 Detail
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-2
(MALE CONN)PLUG
(FEMALE CONN)RECEPT.
CONNECTOR J2
CONNECTOR J1
TX. DATA REC. DATA
INP
UT
CO
NN
J1
RS
-485
INPU
TS O
R O
UTP
UTS
S/N XXXXXXXXX
P/N XXXXXXXXX
XXXXXXXXX
BATESBURG, SC 29006645 RUSSELL ST.
UNION SWITCH & SIGNAL INC.
MADE IN USA
1D2.
0004
.040
2.00
25-PIN PORTS (2)
LEDS
Figure 1-2. ATCS Radio Serial Isolators N16404701 & N16404702 Detail
UNION SWITCH & SIGNAL645 RUSSELL ST.BATESBURG, SC 29006
CONNECTOR 1
POWER
(FEMALE CONN)RECEPT.
BATT -
BATT+
(MALE CONN)PLUG
CONNECTOR 2
BATTERY TERMINALS
SERIAL PORTCONNECTORS
1D2.
0004
.042
2.00 ISOLATOR LABEL
Figure 1-3. RS-232/423 Triple Isolated Serial Isolator N16401103 Detail
1.2. Operation
The MicroLok II serial isolators are designed to protect data channels from undesirable transient signals or voltages that might otherwise corrupt transmitted or received data.
Several models of serial isolators are available. Refer to Table 1-1, Figure 1-1, Figure 1-2, and Figure 1-3.
MicroLok is a registered trademark of Hitachi Rail STS USA, Inc.
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-3
1.2.1. RS-232/423-Compatible Serial Isolator
The RS-232/423 Serial Isolator Unit protects RS-232/RS-423 type communication lines between the MicroLok II CPU PCB or CSI PCB and the external code system from signal voltage transients. The unit operates from signal battery and provides isolation between the host system and the serial code line, RFL carrier, remote MicroLok II, or modem. Battery for the isolator unit must be the same battery used by the host system. The unit also provides isolated ±12V to power the modem, if required. The RS-232 unit accepts communications up to 9600 baud.
The RS-232/423 Serial Isolator is contained in an assembled high impact plastic, two-piece case designed for four-point mounting on a rack panel or other suitable surface. Data cabling is attached on two 25-pin “D” connectors. Unit operating power is connected on a two-terminal screw plug.
1.2.2. ATCS Radio-Compatible Serial Isolators
The ATCS radio-compatible Serial Isolator provides transient signal protection on Motorola MCP radio-based non-vital serial communications links with MicroLok II. Two versions of this isolator unit are available, including a unit for an RS-422 to EIA/TIA-232 (DCE) interface, and a second unit for EIA/TIA-485 to EIA/TIA-232 (DCE) interface. The interface is isolated from input to output at 2000VAC RMS. The RS-422/232 unit accepts communications up to 9600 baud. The RS-485/232 unit works with faster 19200 baud communications typically required for this interface. Isolator unit power is supplied over the MicroLok II CPU or CSI PCB link, depending on the application.
The ATCS Radio Serial Isolator is contained in a high impact plastic, two-piece case designed for four-point mounting on a rack panel or other suitable surface. Data cabling is attached by two 25-pin "D" connectors on the unit’s top cover.
1.2.3. Triple Isolation Serial Isolator
The Triple Isolation Serial Isolator protects RS-232 communication lines between the MicroLok II CPU (DTE equipment) and the external code system (DCE equipment/communication equipment/modem) from signal voltage transients and from the signal battery. The unit operates from signal battery and provides 1500 VAC RMS isolation between the host system and the serial code line, RFL carrier, remote MicroLok II, and Modem. Both the MicroLok II 25-pin D connector and the modem communication connector inputs and outputs are isolated from each other and to the signal battery by 1500 VAC RMS for one minute. The Triple Isolation Serial Isolator unit baud rates are 1200, 2400, 4800, 9600, and 19200.
Data cabling is attached to two 25-pin "D" connectors. The Triple Isolation Serial Isolator unit is contained within a high-impact plastic case, two-piece case designed for four-point mounting on a rack panel or other suitable surface.
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-4
NOTE
Certain pins of the male and female DB-25 connectors on the isolator are tied together. A label (Figure 1-4) lists the tied-together pins is affixed to the side of the isolator. Be aware of these pins when making wiring connections.
1D2.
0004
.042
3.00
Figure 1-4. Triple Isolation Serial Isolator Connector Label
1.3. Rack Mount Panel
A 19-inch rack-mounted micarta panel (M16404901) is available that can contain up to three ATCS Serial Isolator units (see Figure 1-5). No hardware is supplied. Use twelve ¾" long 10-32 pan head screws, stainless steel, and twelve 10-32 nuts, stainless steel, for the three isolator units.
TX. DATA REC. DATA
CONNECTOR J1
CONNECTOR J2
RECEPT.(FEMALE CONN)
PLUG(MALE CONN)
TX. DATA REC. DATA
CONNECTOR J1
CONNECTOR J2
RECEPT.(FEMALE CONN)
PLUG(MALE CONN)
TX. DATA REC. DATA
CONNECTOR J1
CONNECTOR J2
RECEPT.(FEMALE CONN)
PLUG(MALE CONN)
INP
UT
CO
NN
J1
RS
-485
INPU
TS O
R O
UTP
UTS
S/N XXXXXXXXX
P/N XXXXXXXXX
XXXXXXXXX
BATESBURG, SC 29006645 RUSSELL ST.
UNION SWITCH & SIGNAL INC.
MADE IN USA
S/N XXXXXXXXX
P/N XXXXXXXXX
XXXXXXXXX
BATESBURG, SC 29006645 RUSSELL ST.
UNION SWITCH & SIGNAL INC.
MADE IN USA
S/N XXXXXXXXX
P/N XXXXXXXXX
XXXXXXXXX
BATESBURG, SC 29006645 RUSSELL ST.
UNION SWITCH & SIGNAL INC.
MADE IN USA
1D2.
0004
.040
4.00
PRE-DRILLED PANEL
(SERIAL ISOLATOR UNITS SHOWN ARE NOT INCLUDED)
Figure 1-5. Rack-Mount Panel (M16404901) for ATCS Radio Serial Isolators
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-5
1.4. Adapter PCB
A small Adapter PCB is available that mates with and reduces the 25-pin "D" pinouts on the front of the RS-422 to EIA/TIA-232 (DCE) isolator to 9-pin type connectors (refer to Figure 1-6). This Adapter PCB is also equipped with a 2-post wiring terminal to connect external 12V when required by the application. The Adapter PCB cannot be used with the ATCS Serial Isolator EIA/TIA-485 to EIA/TIA-232 (DCE) (N16404702).
1D2.
0004
.040
3.01
9-PIN FEMALE PORTS
POWER TERMINALS
Figure 1-6. Adapter PCB (N39902601) for the ATCS Radio Serial Isolator RS-422 to EIA/TIA-232 (DCE)
1.5. User Interface
Data transmitted to the ATCS Radio Serial Isolator unit from the MicroLok II and data received from the radio is monitored with two LEDs on the isolator's cover.
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-6
1.6. Serial Isolator Unit Specifications
Table 1-2. RS-232/423 Serial Isolator Specifications
PARAMETER SPECIFICATION
STS USA Part No. N16401101
Supported Serial Modes RS-232/RS-423
Input/Output Isolation 1500 VAC RMS @ 60 Hz
Power Input 9.5 to 16.5Vdc (signal; battery)
Modem Power Outputs +12V and -12V
Data Rate 1,200 to 9600 baud
Serial Cable Connections Two 25-pin “D” connectors:
J1 – Male, Inputs J2 – Female, Outputs
Power Connections Two discrete-wire terminals with adapter PCB – N39902601
Unit Mounting Four mounting points for mounting on rack panel or other surfaces
Temperature Range -40ºC to +70ºC
Table 1-3. ATCS Radio-Compatible Serial Isolator Specifications
PARAMETER SPECIFICATION
STS USA Part No. N16404701 and N16404702
Supported Serial Modes RS422 to EIA/TIA-232 (DCE) – N16404701 EIA/TIA-485 to EIA/TIA-232 (DCE) – N16404702
I/O Isolation 2000 Vac RMS
Power Input On-unit: 9.5 to 16.5Vdc (12Vdc nom.) over serial link With adapter PCB: 12 Vdc (nom.) via 2-terminal connector with adapter PCB – N39902601
Data Rates N16404701 (422/232): 9.6K baud N16404702 (485/232): 19.2K baud
Serial Cable Connections
Two 25-pin D connectors as follows: J1, male, inputs J2, female, outputs
Or
Two 9-pin D connectors, female, on adapter PCB N399026 as follows J3, inputs J4, outputs
Unit Mounting Four mounting points for mounting on rack panel or other surfaces
Temperature Range -40ºC to +70ºC
Table 1-4. RS-232 Triple Isolator Specifications
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-7
PARAMETER SPECIFICATION
STS USA Part Number N16401103 Supported Serial Mode RS-232
Power Input and Power Connections 9.8VDC to 16.2VDC (12VDC Nominal on two pin screw terminals on top face of Isolator Unit). Power Input Wire AWG: 18 AWG to 12 AWG
Modem Voltage Outputs +10V and -10 VDC levels Data Rate 9.6K baud I/O Isolation 1500 VAC RMS @60 Hz for one minute
Serial Cable Connections
Two DB25 D connectors as follows: J1, Male, Inputs, J2, Female, Outputs Dual pin layout for maximum flexibly See wiring table on the side of the unit for pin connections (Figure 1-4)
Unit Mounting Four mounting points for mounting on rack panel or other surfaces
Temperature Range -40° F to 158° F (-40°C to 70°C), 95% relative humidity at signal battery inputs from 9.8 VDC to 16.2 VDC
1.7. PCB Addressing and Communication
There is no addressing associated with the serial link isolator units.
1.8. I/O Interface
NOTE
Exercise care to ensure that devices that are serially connected directly to a MicroLok II unit DO NOT have serial connections to devices that might ground serial common.
The serial commons for all MicroLok II serial ports are connected directly to negative vital battery AND to each other. This means that anything connected to any serial port common is also connected to negative vital battery. Furthermore, anything connected to the serial common of any equipment that is directly connected to any MicroLok II serial port is connected to negative vital battery through MicroLok II. This imposes serious restrictions on the characteristics of the devices that can be DIRECTLY CONNECTED to the MicroLok II serial ports. For example, most commercial data modems connect their serial common to earth ground, either directly or through a low resistance. Also, most data radios connect their serial common directly to their antenna ground. Both of these conditions create a problem since they introduce a connection between negative vital battery and earth ground.
Isolation between serial commons is necessary when serially connecting MicroLok II units that are powered by different batteries. As these battery power supplies are considered vital and are required to float with respect to earth ground, significant potential differences can develop between the battery negatives. These potential differences could conceivably be equalized by the connection between serial commons.
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-8
This situation poses a threat both to communication circuit reliability and the electrical integrity of the connected MicroLok II units. In addition, interconnection of battery commons by any means is not a recommended practice.
This situation is remedied by introducing a serial line isolator in the serial line between the MicroLok II units. This unit provides a high level of isolation between the signal commons of MicroLok II and serial devices such as modems and data radios.
The RS-232 link from the MicroLok II CPU Com Port passes through an STS USA serial isolator before going to the modem. This ensures there will be no grounding problems between interconnected MicroLok II units.
Refer to Figure 1-7 for a typical wiring diagram for Serial Isolator N16401101.
Code SystemInterface PCB
48-pinConn.
B12
N12
E2
C2E6
C4
C12A8
A6
S1TXD
S1RXDS1RTS
S1RXD+
S1COM
S1DCD+S1DCD-
SlavePort
Serial LinkIsolator UnitN16401101
Serial LineCarrier
25
12
24
10
2512
24
10
23 23
EarthGnd
Data In
Data OutKey-On
Signal Common
Carrier Detect
1D2.
0004
.040
5.01
MicroTrax In Plug MicroLok In Plug
Figure 1-7. RS-232/423 Serial Isolator Typical Wiring Diagram
All MicroLok II serial ports are identified as Data Line Terminating Equipment (DTE). This means that Transmit Data (TXD) and Request To Send (RTS) signals are outputs and Receive Data (RXD), Data Carrier Detect DCD), and Clear To Send (CTS) are inputs. The STS USA serial isolators are identified as Data Carrying Equipment (DCE) and Transmit Data (TXD) and Request To Send (RTS) are inputs and Receive Data (RXD) and Data Carrier Detect (DCD) are outputs.
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-9
Normal serial connections between the MicroLok II and the serial isolator will be as follows:
MICROLOK II (DTE)
TXD TXD
RXD RXD
DCD DCD
RTS RTS
SERIAL ISOLATOR (DCE)1D
2.00
04.0
421.
00
Depending upon the application in which a Serial Isolator Unit is used, the following connector cables are available for data input and output transmission functions.
Table 1-5. Serial Link Isolator Unit Connector Cables
CABLE PART NO. DESCRIPTION FIGURE REFERENCE
N16919401 I-LOK to Serial Isolator Figure 1-8
N16919601 E-Lok to Serial Isolator Figure 1-9
N16919701 MLK II Port 3 via CPU Cable N16915601 to Serial isolator Figure 1-10
N32500301 GEN II Port 3 via CPU Cable N16916801 to Serial isolator Figure 1-11
N16919501 Serial Isolator to Rugged Server RS400 Figure 1-12
N16921701 GEN II Ports 3 and 4 Serial Isolators Figure 1-13
N16917201 Serial Isolator ATCS DB25F to Radio DB25M Figure 1-14
N16919901 Serial Isolator ATCS DB25F to Radio ATCS MIL-SPEC Figure 1-15
N16920701, 02, 03 Serial Isolator DB25M to Radio WCM RJ45 Figure 1-16
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-10
MALE
PIN
S
TO i-LOK TO ISOLATOR
25 PINDB25M
23DCD
24RTS
25TXD
12RXD
13COM
R
BU
G
MICROTRAX IN PLUG(N16401101)
ORCONNECTOR 1 PLUG
(N16401103)
FEMALE PINS
25 PINDB25F
25
12
10
W
4 FT.FLAT SIDE FLAT SIDE
P/N N16919401REV. NO. XX
PIN # 1 PIN # 1
1D2.
0004
.041
5.01
Figure 1-8. I-LOK to Serial Isolator Cable N16919401
FEM
ALE
PIN
S
TO END POINT TO ISOLATOR
25 PINDB25F
8 DCD
4 RTS
2 TXD
3 RXD
7 COM
R
G
BU
25 PINDB25F
25MICROTRAX IN PLUG
(N16401101)OR
CONNECTOR 1 PLUG(N16401103)
12
10
W
4 FT.
FLAT SIDE FLAT SIDE
P/N N16919601REV. NO. XX
PIN # 1
FEMALE
PINS
PIN #1
1D2.
0004
.041
2.01
Figure 1-9. E-LOK to Serial Isolator Cable N16919601
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-11
FEM
ALE
PIN
S
25 PINDB25F
8
4
2
3
7
RTXD
BUCOM
RTS
G
25 PINDB25F
25
12
10
WRXD
FLAT SIDE
P/N N16919701REV. NO. XX
PIN # 1FEM
ALE
PIN
S
11W REF-
DCD
4 FT.
TO MLK II TO ISOLATOR
PIN #1
1D2.
0004
.041
6.01
MICROTRAX IN PLUG(N16401101)
ORCONNECTOR 1 PLUG
(N16401103)
Figure 1-10. MLK II Port 3 via CPU Cable N16915601 to Serial Isolator Cable N16919701
MAL
E P
INS
25 PINDB25M
8
4
2
3
7
R
BU
G
25 PINDB25F
25
12
10
W
FLAT SIDE
P/N N32500301REV. NO. XX
PIN # 1
FEM
ALE P
INS
11W
4 FT.
TO GEN II TO ISOLATOR
PIN #1
TXD
RXD
COM
REF-
RTS
DCD1D2.
0004
.041
4.01
MICROTRAX IN PLUG(N16401101)
ORCONNECTOR 1 PLUG
(N16401103)
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-12
Figure 1-11. GEN II Port 3 via CPU Cable N16916801 to Serial Isolator Cable N32500301
M
ALE
PIN
S
TO ISOLATOR TO RS-400
MAL
E P
INS
25 PINDB25M DB9M
WRXD
25
5
2
3
12
10
9 PIN
RTXD
BUCOM
6 FT.
P/N N16919501REV. NO. XX
PIN # 1
PIN # 1
FLAT SIDEFLAT SIDE
1D2.
0004
.042
0.01
MICROLOK IN PLUG(N16401101)
ORCONNECTOR 2 PLUG
(N16401103)
Figure 1-12. Serial Isolator to Rugged Server RS400 Cable N16919501
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-13
P2RXD+
a c e
C18
E18
A26
E20+5V
C24BR +12V
C26W -12V
E22BK COM
A24G
A18BU
R
2
3
7
18
21
24
N/C
N/CBR
A4W
A2G
C8R
C6BK
BU
SPARE
SPARE
E20+5V
E22BU COM
C30G
E32Y
C32R
C28BR
W
E PROMPCB
N170020-01
2
P2TXD+
P2RXD-
C24+12V
C18BK COM
A8BU
A6W
E14G
E16BR
R
J1-2
J1-3
J1-15
J1-17
J1-7
J1-21
P3TXD
P3RXD
P3TXC
P3RXC
P1RXD-
P1RXD+
PITXD-
PITXD+
Z
Z
Y
Y
X
X
W
W
P3REFCOM
TO ATCS ISOLATOR
TO SERIAL ISOLATOR
(MA
LE)
TO CLA INTERFACE
TO M
KL II
CPU
TO A
TCS
ISO
LATO
RTO
CLA
INTE
RFA
CE
142
163N/CN/C
(FE
MA
LE)
72 "
72 "
N/C
N/C
N/C
A32W
C22G
C20BR
25
12
10
N/C
N/C
N/C
P4TXD
P4RXD
COM
TO S
ER
IAL
ISO
LATO
R
(FEM
ALE
)
PART # TO MLK II CPU
PIN 1
PIN 13
PIN 14
PIN 25
PIN A2
PIN E32
25 "
PIN 1
PIN 13
PIN 14
PIN 25
R
BK
BU SPARE
SPARE
SPARE
PIN 1PIN 14
PIN 25PIN 13
C16
A14
P4DCD
P4RTS
(FE
MA
LE)
PIN 13PIN 25
PIN 14PIN 1
72"
1D2.
0004
.041
3.01
MIC
RO
TRA
X IN
PLU
G(N
1640
1101
)O
RC
ON
NE
CTO
R 1
PLU
G(N
1640
1103
)
Figure 1-13. GEN II Ports 3 and 4 to Isolator Serial Isolators Cable N16921701
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-14
PIN #1
PIN #25
PIN #1
PIN #25
(MA
LE)
(FEM
ALE
)
J2-2 3 (RXD-)
RTXD+
SHLD
25 PIN CONN. 25 PIN CONN.
PIN #13
PIN #14PIN #14
PIN #13
FEMALE MALE
J2-14 16 (RXD+)
BLKTXD-
J2-15 17 (RXC-)
WTXC+J2-12 9 (RXC+)
BLKTXC-
J2-3 2 (TXD-)
GRXD+J2-16 14 (TXD+)
BLKRXD-
J2-17 24 (TXC-)
BURXC+J2-9 18 (TXC+)
BLKRXC-
J2-7 7 (COM)
Y
BLKCOM
6 '
PART#REV.#
1D2.
0004
.041
7.01
Figure 1-14. Serial Isolator ATCS DB25F to Radio DB25M Cable N16917201
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-15
(FEM
ALE
)
R
SHLD
25 PIN CONN.15 PIN CONN.FEMALE
BLK
W
BLK
G
BLK
BU
BLK
Y
BLK
PART#REV.#
P
PIN 1
PIN 13
PIN 14
PIN 25
6 '
1D2.
0004
.041
9.01
J2-2 H (RXD-)
TXD+J2-14 J (RXD+)
TXD-
J2-15 F (RXC-)
TXC+J2-12 G (RXC+)
TXC-
J2-3 D (TXD-)
RXD+J2-16 E (TXD+)
RXD-
J2-17 B (TXC-)
RXC+J2-9 C (TXC+)
RXC-
J2-7 R (COM)COM
Figure 1-15. Serial Isolator ATCS DB25F to Radio ATCS MIL-SPEC Cable N16919901
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-16
The Serial Isolator to WCM cable illustrated in Figure 1-16 is available in three lengths (L): Part No. N16920701 – 6 ft. Part No. N16920702 – 15 ft. Part No. N16920703 – 30 ft.
WCM ISOLATOR
L
PIN 1
PIN 13
PIN 1
PIN 25
PIN 14
WCM ISOLATOR
MICROLOK IN PLUG(N16401101)
ORCONNECTOR 1 PLUG
(N16401103)
(MA
LE)
WCM PORT 1
DB25 RJ45
25121024
TXDRXDCOMRTS
RXDTXDCOMCTS
4186
PART NUMBER WCM PORT 1
1D2.
0004
.041
8.01
Figure 1-16. Serial Isolator DB25M to Radio WCM RJ-45 Cable N16920701, 02, and 03
1.9. System Applications
The MicroLok II system can be configured to manage communications with a remote non-vital code system. This code system would in turn handle interlocking communications with a central control office. For most code system applications, a Genisys II CPU printed circuit board is installed in the MicroLok II system cardfile, and a serial isolator unit is connected into the serial communication lines. Refer to Figure 1-17 through Figure 1-20 for typical wiring diagrams for Serial Isolator N16401101 used in different configurations.
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-17
MASTER OR SLAVEMICROLOK II
CPU TO MICROLOK II BATTERY
RFL CARRIER SET
A14
PORT 4
REQUEST TO SEND OR KEY ON
DATA CARRIER DETECT OR SQUELCH
RTS24 24
N12 B12
C20TXD
C22RXD
C16DCD
E22COM
10 10
23 23
12 12
25 25 DATA OUT
DATA IN
SIGNAL COMMON
SERIAL COMMUNICATIONCIRCUIT ISOLATION
UNIT N164011011D2.
0004
.040
7.01
Figure 1-17. Typical Microlok II Master or Slave to RFL Serial Modem Interface RS-232 Port 4 with Serial Isolator (Microlok or Genisys Protocol)
MASTER OR SLAVEMICROLOK II
CPU TO MICROLOK II BATTERY
RFL CARRIER SETPORT 3
REQUEST TO SEND OR KEY ON
DATA CARRIER DETECT OR SQUELCH
RTS24 24
N12 B12
TXD
RXD
DCD
COM10 10
23 23
12 12
25 25 DATA OUT
DATA IN
SIGNAL COMMON
SERIAL COMMUNICATIONCIRCUIT ISOLATION
UNIT N16401101
RXREF
CTS
-12VC26
E12
E18
C18
E10
E14
E16
C14
1D2.
0004
.040
8.01
Figure 1-18. Typical Microlok II Master or Slave to RFL Serial Modem Interface RS-232 Port 3 with Serial Isolator (Microlok or Genisys Protocol)
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-18
MASTERMICROLOK II
CPU TO MASTER MICROLOK II BATTERY
A14
PORT 4
RTS24 24
N12 B12
C20TXD
C22RXD
C16DCD
E22COM
10 10
23 23
12 12
25 25
SERIAL COMMUNICATIONCIRCUIT ISOLATION
UNIT N16401101
SLAVEMICROLOK I37-PIN D, F
DCD5
RXD 14
TXD16
RTS13
SIGCOM 1
RXCOM 18
SIGCOM 19
RTS 32
CTS 111D2.
0004
.040
9.01
Figure 1-19. Typical Microlok II Master or Slave Serial Interface RS-232 Port 4 with Serial Isolator (Microlok or Genisys Protocol)
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-19
MASTERMICROLOK I37-PIN D, F
TO SLAVE MICROLOK II BATTERY
RTS24 24
N12 B12
TXD
RXD
DCD
10 10
23 23
12 12
25 25
SERIAL COMMUNICATIONCIRCUIT ISOLATION
UNIT N16401101
SLAVEMICROLOK II
CPU
DCD
RXD
TXD
RTS
PORT 3
E10
E14
E16
C14
COMC18
RXREFE18
CTS E12
-12VC26
13
16
14
5
1SIGCOM
18 RXCOM
19SIGCOM
32 RTS
11 CTS
1D2.
0004
.041
0.01
Figure 1-20. Typical Microlok II Master to Microlok II Slave Serial Interface RS-423 Port 3 with Serial Isolator (Microlok Protocol)
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-20
A serial isolator is required between the GENISYS II serial port and the ATCS MCP. Refer to Figure 1-21 for typical interconnections.
E16TXD-
TXC-
RXD-
RXC-
REF-
COM
+12V
A6
E14
A8
E18
C18
C24
SERIALPORT 3
DB25F DB25M
GENISYS II48-PIN HARTING
CONNECTORATCS
RADIOCONNECTORS
J1-2 J2-2
J1-15
J1-3
J1-17
J1-7
J1-21
J2-14
J2-15
J2-12
J2-3
J2-16
J2-17
J2-9
J2-7
RXD- (A)
RXD-
RXD+ (B)
RXD+
RXC- (A)
RXC-
RXC+ (B)
RXC+
TXD- (A)
TXD-
TXD+ (B)
TXD+
TXC- (A)
TXC-
TXC+ (B)
TXC+
COMCOM
RS-232 - RS-422SERIAL ISOLATOR
N164047011D2.
0004
.041
1.01
Figure 1-21. Typical ATCS WIU Protocol Radio Connection
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-21
1.10. Configuration Options
Refer to the following illustration for a configuration using serial isolator units for vital and non-vital serial communications.
Non-Vital LinkNon-Vital Link
MicoLok IIMicroLok
MicroTrax(Master or Slave)
Vital Link
SerialIsolator
RFL Carrieror
Data Radio
SerialIsolator
MicroLokII
CPU
PowerSupply
MicroLok IISystemCardfile
GenII
CPU
CPU Board Interfaces1D2.
0004
.040
6.01
Figure 1-22. Microlok II Vital and Non-Vital Serial Communications
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 1-22
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 2-1
2. TECHNICAL SUPPORT
The Rapid Action Information Link Team (RAIL Team) is a group of experienced product and application engineers ready to assist you to resolve any technical issues concerning this product. Contact the RAIL Team in the United States at 1-800-652-7276 or by e-mail at [email protected].
Serial Link Isolator Units
Copyright 2019 1D2.0004 Rev. 2, March 2019 2-2
End of Module