607 PRO Heavy Duty Vacuum Pumps
Liquid Cooled
Fan Cooled Side Valve
Fan Cooled
Reliable – Efficient – Cost Effective
380 CFM
#1 Industrial Duty Vacuum Pump
Blower4310Series
Series
607-
SeriesVacuum pumps & Blowers
• Lifetime warranty on the housing against cracking• The NVE bi-rotational, four port oil pump is exclusive to our “oil management system” delivering the precise amount of oil required for any job. Easily adjustable to 5-24 ounces per hour.• Rugged braided stainless steel oil delivery lines• Integral vacuum relief valve• Vane flush port with valve• Vane wear inspection port
• Proven crash protection allowing all major components to survive a catastrophic failure• Remote mount 5 quart see through oil tank for constant oil level monitoring• Integral, easily accessible, final filter• Thermometer to monitor exhaust temperature• Multiple drive options (gearbox, belt, hydraulic, and direct)• Two year warranty against manufacturer defect• Designed, built, and supported in the USA
Product Features:
607 Heavy Duty Vacuum Pumps
©2016 National Vacuum Equipment, Inc. | Revised 02/2016
* Images & specifications for reference only
natvac.com
Please see set up & operation guide for operating parameters.
607 PRO Challenger Fan Cooled
607 PRO Side Valve Challenger Fan Cooled
607 PRO Challenger Liquid Cooled
Blower4310Series
Series
607-
SeriesVacuum pumps & Blowers SECTION C-C
SCALE 1 / 4
SECTION B-BSCALE 1 / 4
MOUNTING HOLE LOCATIONSVIEW D-D
SCALE 1 / 4
1
1
2
2
3
3
4
4
5678
A
B
C
D D
NVE NationalVacuum
Equipment, Inc.2670 Aero Park Drive, Traverse City, MI 49686Phone: (231) 941-0215 Fax: (231) 941-2354
TOLERANCES UNLESS OTHER WISE SPECIFIED
One place (.X) ±.1Two places (.XX) ±.03Three places (.XXX) ±.015Angles ±1°All machined surfaces 125 RMS max.Remove all burrs and sharp edges.CAD drawing - NO manual changes.All dimensions in inches unless specified.
This document may contain confidential tradesecret information which is the exclusive
property of National Vacuum Equipment. Anyinformation on this drawing is not to be
disclosed to anyone not having a "Need toKnow." The information contained herein is to
be used only in accordance with the bestinterests of National Vacuum Equipment.
PART NAME:
607 LIQ COOLED CHALLENGERMATERIAL:
DRAWN BY:
SCALE:
CHECKED BY:
DATE:RPT BOB
PART NO.SHEET2 100-607-L(D & S)2 of
1:4
SEE BOM
APPROX. WT.CAD FILE LOCATION: P:\Data\CAD - Production\100-607-LD & S.idw
SHEET SIZE D
B
B
D
D
REVISION HISTORYREV DATE DESCRIPTION APPROVED ZONE
H 11/1/2010 120-003-002 & 003 WAS 120-003-001, OIL FLOW CHG'D TO 15-18 OZ/HR ECN 1184 D8
B8
J 12/29/2010
REMOVED PINS 120-0T5320-408-009 WAS 320-006320-408-010 WAS 320-005
REMOVED 320-083-001RENUMBERED BALLOONS
ADDED OIL TANK FILTER ASSY
ECN 1195 -
D) BORE - FRONT
D) BORE - FRONT
B) FRONT BEARING
A) REAR BEARING
3" FNPT
3/4" FNPT
(4.73)
(8.15)
(28.92)
(14.73)
14.75"
(4.00)
(18.80)
3" FNPT
1.499
.375 SQ
7.25 B.C.
1/2-13 UNC1.00 DP
B) FRONT BEARING
B) FRONT BEARING
A) REAR BEARING
D) BORE - FRONT
B) FRONTBEARING
100-607-LS (COUNTER CLOCKWISE)
OIL LINE ROUTING: 100-607-LDDESIGNATION DESCRIPTION TYPE PART NUMBER LENGTH (IN)
A R. BEARING OIL LINEPROTECTOR
320-407-001-607LD1320-409-002-607LD1
7.255.25
B F. BEARING OIL LINE
PROTECTOR320-407-001-607LD2320-409-002-607LD2
30.2528.25
C BORE - REAR OIL LINEPROTECTOR
320-407-001-607LD3320-409-002-607LD3
11.009.00
D BORE - FRONT OIL LINEPROTECTOR
320-407-001-607LD4320-409-002-607LD4
25.5023.50
OIL LINE ROUTING: 100-607-LSDESIGNATION DESCRIPTION TYPE PART NUMBER LENGTH (IN)
A R. BEARING OIL LINEPROTECTOR
320-407-001-607LS1320-409-002-607LS1
7.255.25
B F. BEARING OIL LINEPROTECTOR
320-407-001-607LS2320-409-002-607LS2
31.2529.25
C BORE - REAR OIL LINEPROTECTOR
320-407-001-607LS3320-409-002-607LS3
15.0013.00
D BORE - FRONT OIL LINEPROTECTOR
320-407-001-607LS4320-409-002-607LS4
25.5023.50
NOTE EXTRA P-CLIP
NOTE P-CLIP ONBEARING COVER
NOTE P-CLIP ON BEARING COVER
C) BORE -REARC) BORE - REAR
C) BORE - REARC) BORE - REAR
(11.032)
11.500
(5.516)
5.750
(8.985) 13.375
(13.500)(8.922).688
13.375"11.5"
8"
1.499
.375 SQ
29"
29"
(23.85)
11.500(5.75)
(1.662)
(.89)13.375(8.96)
(6.69) Ø.6884 PLCS
SHAFT
KEY
COOLANT LINE
SECTION C-CSCALE 1 / 4
MOUNTING HOLE LOCATIONSVIEW D-D
SCALE 1 / 4
SECTION B-BSCALE 1 / 4
1
1
2
2
3
3
4
4
5678
A
B
C C
D D
NVE NationalVacuum
Equipment, Inc.2670 Aero Park Drive, Traverse City, MI 49686Phone: (231) 941-0215 Fax: (231) 941-2354
TOLERANCES UNLESS OTHER WISE SPECIFIED
One place (.X) ±.1Two places (.XX) ±.03Three places (.XXX) ±.015Angles ±1°All machined surfaces 125 RMS max.Remove all burrs and sharp edges.CAD drawing - NO manual changes.All dimensions in inches unless specified.
This document may contain confidential tradesecret information which is the exclusive
property of National Vacuum Equipment. Anyinformation on this drawing is not to be
disclosed to anyone not having a "Need toKnow." The information contained herein is to
be used only in accordance with the bestinterests of National Vacuum Equipment.
PART NAME:
607 CHALLENGER, FAN COOLEDMATERIAL:
DRAWN BY:
SCALE:
CHECKED BY:
DATE:RPT BOB
PART NO.SHEET2 100-607-F(D & S)2 of
1:4
SEE BOM
APPROX. WT.CAD FILE LOCATION: P:\Data\CAD - Production\100-607-FD & S.idw
SHEET SIZE D398 LBS
C
C
DD
B
B
100-607-FS (COUNTER CLOCKWISE)
15"
29"
3.25"24"
3" NPT
(14.93)
(8.152)
(18.61)
(23.67)
(4.00)
3" NPT
B) FRONT BEARING
B) FRONT BEARING
D) BORE - FRONT
A) REAR BEARING
B) FRONT BEARING B) FRONT BEARING
D) BORE - FRONT A) REAR BEARING REVISION HISTORYREV DATE DESCRIPTION APPROVED ZONE
H 11/1/2010120-003-002 & 003 WAS 120-003-001, OIL FLOW CHG'D TO 12-15 OZ/HR
ECN 1184 D8C8
J 12/29/2010
REMOVED PINS 120-0T5320-408-009 WAS 320-006320-408-010 WAS 320-005
REMOVED 320-083-001RENUMBERED BALOONS
ADDED OIL TANK FILTER ASSY
ECN 1195 -
OIL LINE ROUTING: 100-607-FDDESIGNATION DESCRIPTION TYPE PART NUMBER LENGTH (IN
A R. BEARING OIL LINE 320-407-001-607FD1320-409-002-607FD1
7.255.25
B F. BEARING OIL LINEPROTECTOR
320-407-001-607FD2320-409-002-607FD2
28.2526.00
C BORE - REAR OIL LINEPROTECTOR
320-407-001-607FD3320-409-002-607FD3
11.009.00
D BORE - FRONT OIL LINEPROTECTOR
320-407-001-607FD4320-407-002-607FD4
22.7520.75
OIL LINE ROUTING: 100-607-FSDESIGNATION DESCRIPTION TYPE PART NUMBER LENGTH (IN)
A R. BEARING OIL LINEPROTECTOR
320-407-001-607FS1320-409-002-607FS1
7.255.25
B F. BEARING OIL LINEPROTECTOR
320-407-001-607FS2320-409-002-607FS2
28.2526.00
C BORE-REAR OIL LINEPROTECTOR
320-407-001-607FS3320-409-002-607FS3
15.0013.00
D BORE-FRONT OIL LINEPROTECTOR
320-407-001-607FS4320-409-002-607FS4
22.7520.75
1.499
.375 SQ
C) BORE - REAR
D) BORE - FRONTC) BORE - REAR
C) BORE - REARD) BORE - FRONT
C) BORE - REAR
NOTE P-CLIP ONBEARING COVER
NOTE P-CLIP ONBEARING COVER
(5.750)
11.500
(8.893) (13.500)
(5.516)
(8.956) 13.375
(11.032)
.688
11.5" 13.375"
11.500(5.75)
(.89)13.375
(8.96)
(3.32)
(28.91)
Ø.688 4 PLCS(6.69)
.375 SQ
1.499
(1.662)
(7.95)(4.75)
KEY
SHAFT
OIL LINE VIEWSCALE 1 / 2
SECTION B-BSCALE 1 / 2
12345
6
6
7
7
8
8
A A
B B
C
D
NVE NationalVacuum
Equipment, Inc.2670 Aero Park Drive, Traverse City, MI 49686Phone: (231) 941-0215 Fax: (231) 941-2354
TOLERANCES UNLESS OTHER WISE SPECIFIED
One place (.X) ±.1Two places (.XX) ±.03Three places (.XXX) ±.015Angles ±1°All machined surfaces 125 RMS max.Remove all burrs and sharp edges.CAD drawing - NO manual changes.All dimensions in inches unless specified.
This document may contain confidential tradesecret information which is the exclusive
property of National Vacuum Equipment. Anyinformation on this drawing is not to be
disclosed to anyone not having a "Need toKnow." The information contained herein is to
be used only in accordance with the bestinterests of National Vacuum Equipment.
PART NAME:
607A CHALLENGER, FAN CCWMATERIAL:
DRAWN BY:
SCALE:
CHECKED BY:
DATE:BOB BOB
PART NO.SHEET2 100-607A-FS2 of
1:4
SEE BOM
APPROX. WT.CAD FILE LOCATION: P:\Data\CAD - Production\100-607A-FS.idw
SHEET SIZE D398 LBS
100-607A-FS (COUNTER CLOCKWISE)
OIL LINE ROUTING: 100-607A-FSDESIGNATION DESCRIPTION TYPE PART NUMBER LENGTH (IN)
A R. BEARING OIL LINEPROTECTOR
320-407-001320-409-002
7.255.25
B F. BEARING OIL LINEPROTECTOR
320-407-001320-409-002
27.8125.50
C BORE-REAR OIL LINEPROTECTOR
320-407-001320-409-002
11.139.75
D BORE-FRONT OIL LINEPROTECTOR
320-407-001320-409-002
22.5021.38
B) FRONT BEARING
D) FRONT BOREC) REAR BORE
A) REAR BEARING
A) REAR BEARING
C) REAR BORE
B) FRONT BEARING
D) FRONT BORE
5.750
11.500
5.516
(11.032)
13.375(13.500)
8.893.063
2.88
.688.375 SQ
7.5"
15.5"
3" NPT
23"
16"
29"11.5"13.375"
1.499SHAFT
KEY
Several factory designed and built mounting options available.
607 Challenger SpecificationsAir Flow @ Free Air ........................................ 380 CFMMaximum Vacuum ....................................... 29” HgMaximum Intermittent Pressure ................. 30 PSIOperating Speed - Recommended .............. 1,250 RPMOperating Speed - Intermittent .................... 1,500 RPMHP Required @ 27” Hg ................................. 23HP Required @ 10 PSI ................................. 29HP Required @ 15 PSI ................................. 32HP Required @ 20 PSI ................................. 34Porting Size ................................................... 3”Shaft Size (3/8” Key) ................................... 1 1/2”Approximate Weight ..................................... 390 lbs
8.125”
15”