series cf451t storefront system 2 x 4 for 1 glazing...cf451-13t cf451-4t cf451-1t cf451-4t cf451-5t...
TRANSCRIPT
www.cardcompro.com
SECTION B2SERIES CF451T STOREFRONT SYSTEM
2" X 41/2" for 1" GLAZING
Effective October 2014 www.cardcompro.com 3
SERIES CF451T 2” x 41/2” - B2
TABLE OF CONTENTS
SERIES 451T (Thermal) System Features..................................................................................................................4 - 6 Standard Framing Details .........................................................................................................7 Optional Horizontal Details .......................................................................................................8 Corner and Column Cover Details ............................................................................................9 Horizontal Details - Offset Pivot Hung Doorframe ..................................................................10 Vertical Details - Offset Pivot Hung Doorframe ....................................................................... 11 Horizontal Details - Offset Butt Hung Doorframe ....................................................................12 Vertical Details - Offset Butt Hung Doorframe ........................................................................13 Center Hung Doorframe Details .............................................................................................14 Wind Load and Dead Load Charts ..................................................................................16 - 32 CSISpecifications...........................................................................................................S1 - S4
SERIES 451 (Non-Thermal) Standard Framing Details .......................................................................................................37 Optional Horizontal Details .....................................................................................................38 Corner and Column Cover Details ..........................................................................................39 Horizontal Details - Offset Pivot Hung Doorframe ..................................................................40 Vertical Details - Offset Pivot Hung Doorframe .......................................................................41 Horizontal Details - Offset Butt Hung Doorframe ....................................................................42 Vertical Details - Offset Butt Hung Doorframe ........................................................................43 Center Hung Doorframe Details .............................................................................................44 Butt Glazed Framing with Offset Pivot Hung Entrance Details ...............................................45 Glazing Transitions .................................................................................................................46 Wind Load and Dead Load Charts ..................................................................................48 - 64 CSISpecifications...........................................................................................................S1 - S4
SECTION B2SERIES CF451T (Thermal) STOREFRONT SYSTEM
SERIES CF451 (Non-Thermal) STOREFRONT SYSTEM2" X 4½" FOR 1" GLAZING
4 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2SYSTEM FEATURES
Full height ABS plastic molded end dams to keep infiltrated water contained within subsill receptor where it is weeped to exterior through weep holes backed with baffles. ED451
End Dam
SHIM
Series CF451T Features:Series CF451Tisacommercialflushglazedsystemforexteriorglazinggroundfloorapplicationsorinteriorglazingwhenusedasalowrisewindowwallsystem.Thesystemisdesignedfortheverticalmullionsandfillerplatestorunthroughforoptimumstrength. All Cardinal Commercial Products framing is mechanically jointed using self-tapping screws into integral splines extrudedwithinthebodyofthesection.Jointingisbybuttjointswithappliedsealanttoprotectagainstwateregressandtoreduceairinfiltration.
System features: ►Sightline2”x4½”for1”glazinginfill ►MayalsobeusedforNon-thermalapplications(Series CF451) ►EPDMglazinggaskets ►Shopfabricationandprecisionpunchdiefabricationforscrewsplineholes ►Shopsupervisionandqualitycontrol ►Ladderassemblyfortransportationtojobsiteforquickerinstallation ►Heavydutymullionsand/orsteelreinforcementtomeethighwindvelocityrequirements ►Sillreceptorallowsforheadsofstructuralfastenersinsubsilltobesealedpriortoinstallingladderpanels ►FramingacceptsSeries 200, 300 and 500 entrance doors
Effective October 2014 www.cardcompro.com 5
SERIES CF451T 2” x 41/2” - B2SYSTEM FEATURES
Full height subsill receptor eliminates blind seals where structural fasteners penetrate subsill.
WD451 ABS Plastic Molded Water Diverters
Weep Hole
Glass
Weep Holes backed with 30 ppi polyester baffles
Glass not shownfor clarity.
6 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
Effective October 2014 www.cardcompro.com 7
SERIES CF451T 2” x 41/2” - B2
CF451-13T
CF451-2T CF451-2TCF451-3
CF451-3
CF451-2T CF451-3
CF451-2TCF451-3 CF451-6T
CF451-2TCF451-3 CF451-6T
3
4
52"2"
2"D
.L.O
.
FRA
ME
HE
IGH
T
MA
SO
NR
Y O
PE
NIN
G
MU
LLIO
N L
EN
GTH
D.L
.O.
1 / 4"
1 / 2"
3 / 4"
1 / 4"
41/2"
EXTERIOR GLAZE
3
4
52"2"
2"D
.L.O
.
FRA
ME
HE
IGH
T
MA
SO
NR
Y O
PE
NIN
G
MU
LLIO
N L
EN
GTH
D.L
.O.
1 / 4"
1 / 2"
3 / 4"
1 / 4"
41/2"
INTERIOR GLAZE
1A2B2A21
CF451-13T CF451-4T CF451-4T CF451-1TCF451-1T CF451-5T CF451-7T CF451-8T
CF451-17TGSK-1(Typ)
2" 2" 2" 2" 2"D.L.O. D.L.O. D.L.O. D.L.O.
FRAME WIDTH
MASONRY OPENING
1/4"1/4"
41 / 2"
KEY ELEVATION
1 2
3
2 2 1A
4
5
STANDARD FRAMING DETAILS
8 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
EXTERIOR GLAZE
1
2
3
3 /4"
(Min
.)
13 / 4"
13 / 4"
1 / 4"
D.L
.O.
FRA
ME
HE
IGH
T
MA
SO
NR
Y O
PE
NIN
G
MU
LLIO
N L
EN
GTH
D.L
.O.
KEY ELEVATION
2
3
1
CF451-1T
CF451-18TCF450-19
GSK-1(Typ)
1 / 4"
1 / 2"
3 / 4"
41/2"
41 / 2"
41 / 2"
CF451-11T
CF451-3CF451-3
CF451-11T
CF451-3CF451-3
CF451-6T
CF451-4T
OPTIONAL HORIZONTAL DETAILS
Effective October 2014 www.cardcompro.com 9
SERIES CF451T 2” x 41/2” - B2
NO POCKETS(Post)
ONE POCKET(Terminating End)
OTHER COMBINATIONS
COLUMN COVERS
TWO POCKETS(Straight Wall)
THREE POCKETS(Intersecting Walls)
FOUR POCKETS(Intersecting Walls)
CF450-11
CF450-11
CF451-12T
CF451-12T
CF451-12T CF451-9TGSK-1 (Typ)
CF451-10T CF451-10T
CF451-10T
CF450-11
CF451-12T
CF451-12T
CF451-9T
CF451-9T
GSK-1(Typ)
1 2
90º
CF451-8TCF451-8T
CF451-8T
CF451-8T
Formed Aluminum TrimFormed Aluminum Trim Aluminum Trim
CF450-20
CF451-8T
CF451-8T
3 4
31/16"13/16"
4 1/2"
FRAME WIDTH
D.L.O.
135º
45º
CF450-21
CF450-20
Varies
CF451-21
KEY ELEVATION
190º 90º
2
3135º 45º
4
41/2"41/2"
FRAME WIDTH
D.L.O.
41 / 2"
90º
CF451-8TCF451-8T
CF451-8T CF451-8T
CORNER DETAILS
10 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
CD100-8
T450
3
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
3A
CF200-6-1
CD100-8
T450
2"11 / 8
"
31 / 8"
DLO
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
2A
CF200-5 CF200-4
COC
CF451-32
CF200-1
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
1 / 4"
2"
4A
CF451-32
COC
CF200-1
DLO
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
2"2CF200-8
CF451-31
1 / 4"
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G 2"
4CF200-8
CF451-31
1
DLO
FRA
ME
HE
IGH
T
MAS
ON
RY
OPE
NIN
G
41/2"
1 / 4"
2"
CF451-2CF451-3ENTRANCE
KEY ELEVATION
1
3
2
1
3A
22A 2A
3
4
3A
44A 4A
1" Insulated Glass
1" Insulated Glass
HORIZONTAL OFFSET PIVOT HUNG DOORFRAME DETAILS
Effective October 2014 www.cardcompro.com 11
SERIES CF451T 2” x 41/2” - B2
CD100-2
1" Insulated Glass
DOOR OPENING
5 CF200-6-1T450
D.L.O.D.L.O.
FRAME WIDTH
MASONRY OPENING
2"
1
CF451-30CF451-4T
GSK-1(Typ)
D.L.O. DOOR OPENING
FRAME WIDTH
MASONRY OPENING
DOOR OPENING
1/4"FRAME WIDTH
MASONRY OPENING
2"
3
CF451-30
CF200-8
CF451-4T
GSK-1(Typ)
D.L.O.
1/4"FRAME WIDTH
MASONRY OPENING
2"
2
CF451-30
CF450-17T
2"
4
CF451-30
CF200-8
CF450-17T
ENTRANCEKEY ELEVATION
1 2
3 4
1 2
3 5 4
3 4 3 5 4
VERTICAL OFFSET PIVOT HUNG DOORFRAME DETAILS
12 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
CD100-8
2"11 / 8
"
31 / 8"
DLO
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
1 / 4"
2"
DLO
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
2"
1 / 4"
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G 2"
4
4A
3
2
2A
3A
DLO
FRA
ME
HE
IGH
T
MAS
ON
RY
OPE
NIN
G
1 / 4"
2"
CF200-5 CF200-4
CF451-32
COC COC
CF200-1
CF451-32
CF200-1
CF200-6-1
CD100-8
T450T450
CF200-8
CF451-31
CF200-8
CF451-13T
1
41/2"
ENTRANCEKEY ELEVATION
1
3
2
1
3A
22A 2A
3
4
3A
44A 4A
CF451-311" Insulated Glass
1" Insulated Glass
HORIZONTAL OFFSET BUTT HUNG DOORFRAME DETAILS
Effective October 2014 www.cardcompro.com 13
SERIES CF451T 2” x 41/2” - B2
DOOR OPENING
5 CF200-6-1T450
D.L.O. DOOR OPENING
FRAME WIDTH
MASONRY OPENING
DOOR OPENING
1/4"FRAME WIDTH
MASONRY OPENING
2"
3
CF451-34
CF200-3
CF451-4T
GSK-1(Typ)
CF200-4
CF200-5
CF200-4
CF200-5
CF451-4T
CF200-17T
2"
D.L.O. DLO
FRAME WIDTH
MASONRY OPENING
31/8"
11/8"
31/8"
2"11/8"
DLO
1/4"FRAME WIDTH
MASONRY OPENING
65CF451-34CF451-34
GSK-1(Typ)
2"
4
CF451-34
CF200-3
CF450-17T
ENTRANCEKEY ELEVATION
1 2
3 4
1 2
3 5 4
3 4 3 5 4
CD100-2
1" Insulated Glass
VERTICAL OFFSET BUTT HUNG DOORFRAME DETAILS
14 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
4
7 8
3
2
2"D.L.O. DOOR OPENING
FRAME WIDTH
MASONRY OPENING
2" DOOR OPENING
1/4"FRAME WIDTH
MASONRY OPENING
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
2"11 / 8
"
31 / 8"
D.L
.O.
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
CF200-4
CF200-5
CF200-4
CF200-5
CF451-4T
CF200-17T
2"
D.L.O. DLO
FRAME WIDTH
MASONRY OPENING
31/8"
11/8"
31/8"
2"11/8"
DLO
1/4"FRAME WIDTH
MASONRY OPENING
65
CF451-4T
CF450-17T
13 / 4"
DO
OR
OP
EN
ING
1 / 4"
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
1
DLO
FRA
ME
HE
IGH
T
MAS
ON
RY
OPE
NIN
G
41/2"
2"
1 / 4"
CF451-33
CF450-34
CF451-33
CF450-34
CF451-34CF451-34CF451-34
CF451-34
T450
OptionalWeathering
DOOR OPENING
9
ENTRANCEKEY ELEVATION
1
3
27 8
5 6 6 6
8 9 8
7 88 9 8
1
3
2
3
4
3
4
Opp
Opp
Opp
COC
COC
GSK-1(Typ)
CF451-13
CF200-5 CF200-4
1" Insulated Glass
CD100-2
CENTER HUNG DOORFRAME DETAILS
Effective October 2014 www.cardcompro.com 15
SERIES CF451T 2” x 41/2” - B2
THIS PAGE INTENTIONALLY LEFT BLANK
16 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
20 24 28 32 36 40 44 48 52 56 60 64 68 72 7650
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
CF451-5T/CF451-4TCF451-7T/CF451-8T
CF451-1T/CF451-4T
W
H
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
EXAMPLE ELEVATION
H = Mullion HeightW = Mullion Spacing
CF451T @ 20 PSF
CF451-4T
CF451-4T
CF451-1T
CF451-5T
CF451-7T CF451-8T
CurvesarebasedondeflectionlimitedtoL/175nottoexceed1" and total lateral support of flanges.
WIND LOAD CHARTS(Assumes Total Lateral Support of flanges)
Effective October 2014 www.cardcompro.com 17
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in INCHES
Mul
lion
Hei
ght i
n IN
CH
ES
20 24 28 32 36 40 44 48 52 56 60 64 68 72 7650
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
CF451-5T/CF451-4TCF451-7T/CF451-8T
CF451-1T/CF451-4T
W
H
CF451-4T
CF451-4T
CF451-1T
CF451-5T
CF451-7T CF451-8TCF451 @ 30 PSF
EXAMPLE ELEVATION
H = Mullion HeightW = Mullion Spacing (Center of Light to Center of Light)
CurvesarebasedondeflectionlimitedtoL/175nottoexceed1" and total lateral support of flanges.
WIND LOAD CHARTS(Assumes Total Lateral Support of flanges)
18 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in INCHES
Mul
lion
Hei
ght i
n IN
CH
ES
20 24 28 32 36 40 44 48 52 56 60 64 68 72 7630
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
CF451-5T/CF451-4TCF451-7T/CF451-8T
CF451-1T/CF451-4T
W
H
CF451 @ 40 PSF
EXAMPLE ELEVATION
H = Mullion HeightW = Mullion Spacing (Center of Light to Center of Light)
CF451-4T
CF451-4T
CF451-1T
CF451-5T
CF451-7T CF451-8T
CurvesarebasedondeflectionlimitedtoL/175nottoexceed1" and total lateral support of flanges.
WIND LOAD CHARTS(Assumes Total Lateral Support of flanges)
Effective October 2014 www.cardcompro.com 19
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in INCHES
Mul
lion
Hei
ght i
n IN
CH
ES
20 24 28 32 36 40 44 48 52 56 60 64 68 72 7620
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
CF451-5T/CF451-4TCF451-7T/CF451-8T
CF451-1T/CF451-4T
W
H
CF451 @ 50 PSF
EXAMPLE ELEVATION
H = Mullion HeightW = Mullion Spacing (Center of Light to Center of Light)
CF451-4T
CF451-4T
CF451-1T
CF451-5T
CF451-7T CF451-8T
CurvesarebasedondeflectionlimitedtoL/175nottoexceed1" and total lateral support of flanges.
WIND LOAD CHARTS(Assumes Total Lateral Support of flanges)
20 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
CF451-1T/CF451-4T @ 20 PSF
SP = 120"
SP = 96"
SP = 72"
SP = 60"SP = 48"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
CF451-4TCF451-1T
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 21
SERIES CF451T 2” x 41/2” - B2
CF451-1T/CF451-4T @ 30 PSF
SP = 120"
SP = 96"
SP = 72"
SP = 60"SP = 48"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4TCF451-1T
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
22 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
CF451-1T/CF451-4T @ 40 PSF
SP = 120"SP = 96"
SP = 72"
SP = 60"SP = 48"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4TCF451-1T
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 23
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4TCF451-1T
CF451-1T/CF451-4T @ 50 PSF
SP = 120"SP = 96"
SP = 72"
SP = 60"SP = 48"
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
24 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-5T/CF451-4T @ 20 PSF
SP = 120"
SP = 96"
SP = 72"
SP = 60"SP = 48"
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
CF451-4TCF451-5T
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 25
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4TCF451-5T
CF451-5T/CF451-4T @ 30 PSF
SP = 120"
SP = 96"
SP = 72"
SP = 60"SP = 48"
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
26 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4TCF451-5T
CF451-5T/CF451-4T @ 40 PSF
SP = 120"
SP = 96"
SP = 72"
SP = 60"
SP = 48"
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 27
SERIES CF451T 2” x 41/2” - B2
CF451-5T/CF451-4T @ 50 PSF
SP = 120"SP = 96"
SP = 72"
SP = 60"SP = 48"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4TCF451-5T
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
28 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-7T/CF451-8T @ 20 PSF
SP = 120"
SP = 96"
SP = 72"
SP = 60"
SP = 48"
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
CF451-7T CF451-8T
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 29
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-7T CF451-8T
CF451-7T/CF451-8T @ 30 PSF
SP = 120"SP = 96"
SP = 72"
SP = 60"
SP = 48"
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
30 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-7T CF451-8T
CF451-7T/CF451-8T @ 40 PSF
SP = 120"SP = 96"
SP = 72"SP = 60"
SP = 48"
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 31
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-7T CF451-8T
CF451-7T/CF451-8T @ 50 PSF
SP = 120"SP = 96"
SP = 72"SP = 60"
SP = 48"
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
20 24 28 32 36 40 44 48 52 56 60 64 68 72 76
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
32 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Hor
izon
tal S
paci
ng in
(Inc
hes)
54 57 60 63 66 69 72 75 78 81 84 87 90 93 960
25
50
75
100
125
150
175
200
x = 1/4x = 1/8
EXAMPLE ELEVATION
CF451-2T with 1" Glass
H = Distance between HorizontalsW = Mullion Spacingx = Location of setting blocks as a fraction of W
NOTE: Curves are based on deflection limited to 1/8”.
W W
W/xSetting BlockLocation
W W
H
CF451-2TCF451-3
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H)oftheglassandthewidth(W)ofthemullionspacing.
DEAD LOAD CHART
Effective October 2014 www.cardcompro.com 33
SERIES CF451T 2” x 41/2” - B2Cardinal Commercial Products
ALUMINUM STOREFRONT SYSTEMSERIES CF451T THERMAL
GUIDE SPECIFICATIONS
SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS
This suggested guide specification has been developed using the current edition of the Construction Specifications Institute (CSI) “Manual of Practice,” including the recommendations for the CSI 3 Part Section Format and the CSI Page Format. The developmental concept and organizational arrangement used by the American Institute of Architects (AIA) MASTERSPEC Program were recognized in the preparation of this guide specification. Neither CSI nor AIA endorse specific manufacturers and products. The preparation of the guide specification assumes the use of standard contract documents and forms, including the “Conditions of the Contract,” published by the AIA.
PART 1 – GENERAL
1.01 Summary A. Section Includes: Architectural Aluminum Products by CARDINAL COMMERCIAL PRODUCTS, including perimeter trims, stools, accessories, shims and anchors, and perimeter sealing of storefront framing. 1. TypesofArchitecturalAluminumProductsbyCARDINAL COMMERCIAL PRODUCTS include: a. CF451T:2”x4-1/2”(outside)or(inside)centerglazedthermalstorefrontsystemfor1”insulatedglazing.
EDITOR NOTE: BELOW RELATED SECTIONS ARE SPECIFIED ELSE WHERE, HOWEVER, CARDINAL COMMERCIAL PRODUCTS RECOMMENDS SINGLE SOURCE RESPONSIBILITY FOR ALL OF THESE SECTIONS AS INDICATED IN 2.07 SOURCE QUALITY CONTROL.
B. Related Sections: 1. Division7Section“VaporBarriers”betweenglazedwallsystemsandadjacentconstruction 2. Division7Section“FireStopping” 3. Division7Section“JointSealants”forjointsealantsinstalledaspartofaluminumentranceandstorefrontsystem 4. Division8Section“GlazedAluminumCurtainWalls” 5. Division8Section“AluminumWindowsWalls” 6. Division8Section“AluminumEntrancesandStorefronts” 7. Division8Section“AluminumMallSlidingDoors” 8. Division8Section“FinishHardware” 9. Division8Section“GlassandGlazing”
EDITOR NOTE: REFER TO INDEX FOR ANY AND ALL APPLICABLE STANDARDS.
1.02 References(IndustryStandards)
1.03 System Description A.StorefrontSystemPerformanceRequirements: 1. AirInfiltration:ThetestspecimenshallbetestedinaccordancewithASTM283.Airinfiltrationrateshallnotexceed0.06cfm/ft2ata(static)air pressure differential of 6.24 PSF. 2. WaterResistance,(static):ThetestspecimenshallbetestedinaccordancewithASTM331for(outside)or(inside).Thereshallbenoleakage ataminimumstaticairpressuredifferentialof10PSFasdefinedinAAMA501. 3. UniformLoad:A static air design loadof 35PSFshall beapplied in thepositive andnegativedirection in accordancewithASTME330. ThereshallbenodeflectioninexcessofL/175ofthespanofanyframingmemberatdesignload.Atstructuraltestloadequalto1.5timesthe specifieddesignload,noglassbreakageorpermanentsetintheframingmembersinexcessof0.2%oftheirclearspansshalloccur.
1.04 Submittals A. General:Prepare,review,approve,andsubmitspecifiedsubmittals inaccordancewith“Conditionsof theContract”andDivision1Submittals Sections. Productdata,shopdrawings,samples,andsimilarsubmittalsaredefinedin“ConditionsoftheContract.” B.QualityAssurance/ControlSubmittals: 1. TestReports:Submitcertifiedtestreportsshowingcompliancewithspecifiedperformancecharacteristics.
1.05 Warranty A.ProjectWarranty:Referto“ConditionsoftheContract”forprojectwarrantyprovisions. B.Manufacturer’sProductWarranty:Submit,forOwner’sacceptance,manufacturer’swarrantyforstorefrontsystemasfollows: 1. WarrantyPeriod:Two(2)yearsfromDateofSubstantialCompletionoftheproject.TheLimitedWarrantyshallbegininnoeventlaterthansix months fromdate of shipment byCARDINAL COMMERCIAL PRODUCTSwithout regard to the date selected as substantial completion. In addition, entrance door corner construction shall be supported with a lifetime warranty for the life of the door under normal use.1.06 Quality Assurance A.Qualifications: 1. InstallerQualifications:Installerexperienced(asdeterminedbycontractor)toperformworkofthissectionwhohasspecializedintheinstallationof worksimilartothatrequiredforthisprojectandwhoisacceptabletoproductmanufacturer. 2. ManufacturerQualifications:Manufacturercapableofprovidingfieldservicerepresentationduringconstruction,approvingacceptableinstallerand approving application method. B.Pre-Installation Meetings: Conduct pre-installation meeting to verify project requirements, substrate conditions, manufacturer’s installation instructions,andmanufacturer’swarrantyrequirements.
S1
34 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
GUIDE SPECIFICATIONS(Continued)
1.07 Delivery, Storage, and Handling A.Ordering:Complywithmanufacturer’sorderinginstructionsandschedulingrequirementstoavoidconstructiondelays. B.Packing,Shipping,Handling, andUnloading:Delivermaterials inmanufacturer’s original, unopened, undamagedcontainerswith identification labelsintact. C.StorageandProtection:Storematerialsprotectedfromexposuretoharmfulweatherconditions.Handlestorefrontmaterialandcomponentstoavoiddamage. Protectstorefrontmaterialagainstdamagefromelements,constructionactivities,andotherhazardsbefore,duringandafterstorefrontinstallation.
PART 2 – PRODUCTS
EDITOR NOTE: RETAIN BELOW ARTICLE FOR PROPRIETARY METHOD SPECIFICATION; ADD PRODUCT ATTRIBUTES, PERFORMANCE CHARACTERISTICS, MATERIAL STANDARDS, AND DESCRIPTIONS AS APPLICABLE. DO NOT USE THE PHRASE “OR EQUAL” / “OR APPROVED EQUAL,” OR SIMILAR PHRASES, USE OF SUCH PHRASES CAN CAUSE AMBIGUITY IN THE SPECIFICATIONS DUE TO THE DIFFERENT INTERPRETATIONS AMONG THE DIVERGENT PARTIES OF THE CONSTRUCTION PROCESS AND READERS OF THESE SPECIFICATIONS. SUCH PHRASES REQUIRE EXTENSIVE AND COMPLETE REQUIREMENTS (PROCEDURAL, LEGAL, REGULATORY, AND RESPONSIBILITY) FOR DETERMINING “OR EQUAL.”
2.01 Manufacturers (AcceptableManufacturers/Products) A.AcceptableManufacturers: 1. Address: Cardinal Commercial Products, LLC 4915 Heller Street Louisville, KY 40218 Contact Numbers: a. Telephone: 502-969-4059 b.Fax:502-813-2484 c. Email: [email protected] d.Webaddress:cardcompro.com 2. ProprietaryProduct(s)/System(s):CARDINAL COMMERCIAL PRODUCTS a. Series: CF451T Thermal Storefront System
EDITOR NOTE: RETAIN BELOW FOR ALTERNATE MANUFACTURERS/PRODUCTS AS SPECIFIED IN THE CONTRACT DOCUMENTS. COORDINATE BELOW WITH BID DOCUMENTS (IF ANY), AND DIVISION 1 ALTERNATES SECTION. CONSULT WITH CARDINAL COMMERCIAL PRODUCTS FOR RECOMMENDATIONS ON ALTERNATE MANUFACTURERS AND PRODUCTS MEETING THE DESIGN CRITERIA AND PROJECT REQUIREMENTS. CARDINAL COMMERCIAL PRODUCTS RECOMMENDS OTHER MANUFACTURERS REQUESTING APPROVAL TO BID THEIR PRODUCT AS AN EQUAL, MUST SUBMIT THEIR REQUEST IN WRITING (10) DAYS PRIOR TO CLOSE OF BIDDING. b. Finish/Color:(See2.06Finishes) c. FramingMemberProfile:2”x4-1/2”nominaldimension;CenterGlazed;ScrewSplineFabrication Provide combination full height subsill receptor and sill section which eliminate blind seal conditions at fasteners penetrating subsillreceptor.Subsillreceptortohavefullheightenddamsandweepholesbackedwithbafflestoreduceairinfiltration. B.Alternate(Manufacturers/Products):Inlieuofprovidingbelowspecifiedbasebid/contractmanufacturer,providebelowspecifiedalternatemanufacturers. Refer to Division 1 Alternates Section. 1. BaseBid/ContractManufacturer/Product:CARDINAL COMMERCIAL PRODUCTS a. Product: Aluminum Storefront System b. Series CF451T ThermalStorefrontSystem:2”x4-1/2”nominaldimension,CenterGlazed;Screw-SplineFabrication 2. Alternate#____Manufacturer/Product: a. Product: b. Series: c. FramingMemberProfile: 3. Alternate#___Manufacturer/Product: a. Product: b. Series: c. FramingMemberProfile: C.Substitutions: 1. General:RefertoDivision1Substitutionsforproceduresandsubmissionrequirements. a. Pre-Contract(BiddingPeriod)Substitutions:Submitwrittenrequeststen(10)dayspriortobiddate. b. Post-Contract(ConstructionPeriod)Substitutions:Submitwrittenrequestinordertoavoidstorefrontinstallationandconstructiondelays. 2. SubstitutionDocumentation a. ProductLiteratureandDrawings:Submitproductliteratureanddrawingsmodifiedtosuitspecificprojectrequirementsandjobconditions. b. Certificates:Submitcertificate(s)certifyingsubstitutemanufacturer(1)attestingtoadherencetospecificationrequirementsforstorefrontsystem performance criteria. c. TestReports:Submittestreportsverifyingcompliancewitheachtestrequirementforstorefrontrequiredbytheproject. d. ProductSampleandFinish:Submitproductsample,representativeofstorefrontfortheproject,withspecifiedfinishandcolor. 3. SubstitutionAcceptance:Acceptancewillbeinwrittenform,eitherasanaddendumormodification,anddocumentedbyaformalchangeorder signedbytheOwnerandContractor.
S2
Effective October 2014 www.cardcompro.com 35
SERIES CF451T 2” x 41/2” - B2
GUIDE SPECIFICATIONS(Continued)
2.02 Materials A.Aluminum(StorefrontandComponents): 1. MaterialStandard:ExtrudedAluminum,ASTMB221,A96063-T6and/orA95050-H32alloyandtemper. 2. MemberWallThickness:Eachframingmembershallhaveawallthicknesssufficienttomeetthespecifiedstructuralrequirements. 3. Tolerances:Referencetotolerancesforwallthicknessandothercross-sectionaldimensionsofstorefrontframingmembersarenominalandin compliance with AA Aluminum Standards and Data.
2.03 Accessories A.Fasteners:Whereexposed,shallbeStainlessSteel. B.Gaskets:GlazinggasketsshallcomplywithASTMC864andbeextrudedofsiliconecompatibleEPDMrubberthatprovidesforsiliconeadhesion. C.PerimeterAnchors:Whensteelanchorsareused,provideinsulationbetweensteelmaterialandaluminummaterialtopreventgalvanicaction.
2.04 Related Materials A.Sealants:RefertoJointTreatment(Sealants)Section. B. Glass: Refer to Glass and Glazing Section.
2.05 Fabrication A. General: 1. Fabricatecomponentspermanufacturer’sinstallationinstructionsandwithminimumclearancesandshimspacingaroundperimeterofassembly, yetenablinginstallationanddynamicmovementofperimeterseal. 2. Accuratelyfitandsecurejointsandcorners.Makejointsflush,hairlineandweatherproof. 3. Arrange fasteners and attachments to conceal from view.
EDITOR NOTE: SELECT BELOW FINISH AND COLOR FROM CARDINAL COMMERCIAL PRODUCTS’S STANDARD COLORS. CUSTOM COLORS ARE AVAILABLE UPON REQUEST FROM CARDINAL COMMERCIAL PRODUCTS. OTHER POLYESTER POWDER COATINGS CONFORMING TO AAMA 2604 ARE AVAILABLE. CONSULT WITH YOUR CARDINAL COMMERCIAL PRODUCTS REPRESENTATIVE FOR OTHER SURFACE TREATMENTS AND FINISHES.
2.06 Finishes A. Shop Finishing 1. ColorAnodizingConformingtoAA-M12C22A44,AAMA611,Architectural.Class.I.AnodicCoating(Color:#21DarkBronze).(Standard) 2. ClearAnodizingConformingtoAA-M12C22A31,AAMA611,Architectural.Class.II.ClearAnodicCoating(Clear:#11(Standard) 3. AAMA2605,FluoropolymerPowderCoating(Color:__________). 4. AAMA2604,PolyesterPowderCoating.(Color:__________). 5. Other:Manufacturer____________Type____________Color:__________).
2.07 Source Quality Control A.SourceQuality:Providealuminumstorefrontspecifiedhereinfromasinglesource. 1. BuildingEnclosureSystem:Whenaluminumcurtainwallarepartofabuildingenclosuresystem,includingentrances,entrancehardware,windows, curtainwallframingandrelatedproducts,providebuildingenclosuresystemproductsfromasinglesourcemanufacturer.
PART 3 – EXECUTION
3.01 Examination A.SiteVerificationofConditions:Verifysubstrateconditions(whichhavebeenpreviouslyinstalledunderothersections)areacceptableforproduct installationinaccordancewithmanufacturer’sinstructions.Verifyopeningsaresizedtoreceivespecifiedsystemandsillplateislevelinaccordancewith manufacturer’sacceptabletolerances.
EDITOR NOTE: COORDINATE BELOW ARTICLE WITH MANUFACTURER’S RECOMMENDED INSTALLATION DETAILS AND INSTALLATION INSTRUCTIONS.
1. FieldMeasurements:Verifyactualmeasurements/openingsbyfieldmeasurementsbeforefabrication;showrecordedmeasurementsonshop drawings.Coordinatefieldmeasurements,fabricationschedulewithconstructionprogresstoavoidconstructiondelays.
3.02 Installation A.General: Installstorefrontsystemsplumb, level,andtrueto line,withoutwarporrackof frameswithmanufacturer’sprescribedtolerancesand installation instructions. Provide support and anchor in place. 1. DissimilarMaterials:Provideseparationofaluminummaterialsfromsourcesofcorrosionorelectrolyticactioncontactpoints. 2. Glazing:Glassshallbe(outside)or(inside)glazedandheldinplacewithextrudedEPDMglazinggasketsonbothsidesoftheglass. 3. Water Drainage: Waterdeflectorsshallbeinstalledateachendofintermediatehorizontalallowinginfiltratedwatertodraindownthe verticalmember’sglazingpocket intoa fullheightsubsill receptorwhere itweepstotheexterior throughaseriesofweepholes backedwithbafflestoreduceairinfiltration. B.RelatedProductsInstallationRequirements: 1. Sealants(Perimeter):RefertoDivision7JointTreatment(Sealants)Section. 2. Glass: Refer to Division 8 Glass and Glazing Section. a. Reference:ANSIZ97.1,CPSC16CFR1201andGANAGlazingManual.
S3
36 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
GUIDE SPECIFICATIONS(Continued)
3.03 Field Quality Control A.FieldTests:Architectshallselectstorefrontunitstobetestedassoonasarepresentativeportionoftheprojecthasbeeninstalled,glazed,perimeter caulkedandcured.Conducttestsforairinfiltrationandwaterpenetrationwithmanufacturer’srepresentativepresent.Testsnotmeetingspecified performancerequirementsandunitshavingdeficienciesmustbecorrectedaspartofthecontractamount. 1. Testing:TestingshallbeperformedperAAMA503byaqualifiedindependenttestingagency.RefertoDivisionTestingSectionforpaymentof testingandtestingrequirements. a. AirInfiltrationTests:ConducttestsinaccordancewithASTME783.Allowableairinfiltrationshallnotexceed1.5timestheamountindicated intheperformancerequirementsor0.09cfm/ft2,which,everisgreater. b. WaterInfiltrationTests:ConducttestsinaccordancewithASTME1105.Nouncontrolledwaterleakageispermittedwhentestedatastatic testpressureoftwo-thirdsthespecifiedwaterpenetrationpressurebutnotlessthan8PSF. B.Manufacturer’sFieldServices:UponOwner’srequest,providemanufacturer’sfieldserviceconsistingofproductuserecommendationsandperiodic sitevisitforinspectionofproductinstallationinaccordancewithmanufacturer’sinstructions.
3.04 Protection and Cleaning A.Protection:Protect installedproduct’sfinishsurfaces fromdamageduringconstruction.Protectaluminumstorefrontsystemfromdamage from grinding and polishing compounds, plaster, lime, acid, cement, or other harmful contaminants. B.Cleaning:Repairorreplacedamagedinstalledproducts.Installedproductsaretobecleanedinaccordancewithmanufacturer’sinstructionsprior toowner’sacceptance.Removeconstructiondebrisfromprojectsiteandlegallydisposeofdebris.
DISCLAIMER STATEMENTThis guide specification is intended for useby a qualified construction specifier.Theguide specification is not intended to be verbatimas a project specificationwithoutappropriatemodificationsforthespecificuseintended.Theguidespecificationmustbeusedandcoordinatedwiththeprocedures ofeachdesignfirm,andtheparticularrequirementsofaspecificconstructionproject.
END OF SECTION 08410
S4
Effective October 2014 www.cardcompro.com 37
SERIES CF451T 2” x 41/2” - B2
CF451-13
CF451-2 CF451-2CF451-3
CF451-3
CF451-2 CF451-3
CF451-2CF451-3 CF451-6
CF451-2CF451-3 CF451-6
3
4
52"2"
2"D
.L.O
.
FRA
ME
HE
IGH
T
MA
SO
NR
Y O
PE
NIN
G
MU
LLIO
N L
EN
GTH
D.L
.O.
1 / 4"
1 / 2"
3 / 4"
1 / 4"
41/2"
EXTERIOR GLAZE
3
4
52"2"
2"D
.L.O
.
FRA
ME
HE
IGH
T
MA
SO
NR
Y O
PE
NIN
G
MU
LLIO
N L
EN
GTH
D.L
.O.
1 / 4"
1 / 2"
3 / 4"
1 / 4"
41/2"
INTERIOR GLAZE
1A2B2A21
CF451-13 CF451-4 CF451-4 CF451-1CF451-1 CF451-5 CF451-7 CF451-8
CF451-17GSK-1(Typ)
2" 2" 2" 2" 2"D.L.O. D.L.O. D.L.O. D.L.O.
FRAME WIDTH
MASONRY OPENING
1/4"1/4"
41 / 2"
KEY ELEVATION
1 2
3
2 2 1A
4
5
STANDARD FRAMING DETAILS
38 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
KEY ELEVATION
2
3
1
EXTERIOR GLAZE
1
2
3
3 /4"
(Min
.)
13 / 4"
13 / 4"
1 / 4"
D.L
.O.
FRA
ME
HE
IGH
T
MA
SO
NR
Y O
PE
NIN
G
MU
LLIO
N L
EN
GTH
D.L
.O.
CF451-1
CF451-18CF450-19
GSK-1(Typ)
1 / 4"
1 / 2"
3 / 4"
41/2"
41 / 2"
41 / 2"
CF451-11
CF451-3CF451-3
CF451-11
CF451-3CF451-3
CF451-6
CF451-4
OPTIONAL HORIZONTAL DETAILS
Effective October 2014 www.cardcompro.com 39
SERIES CF451T 2” x 41/2” - B2
NO POCKETS(Post)
ONE POCKET(Terminating End)
OTHER COMBINATIONS
COLUMN COVERS
TWO POCKETS(Straight Wall)
THREE POCKETS(Intersecting Walls)
FOUR POCKETS(Intersecting Walls)
CF450-11
CF450-11
CF451-12
CF451-12
CF451-12 CF451-9
GSK-1 (Typ)
CF451-10 CF451-10
CF451-10
CF450-11
CF451-12
CF451-12
CF451-9
CF451-9
GSK-1(Typ)
1 2
90º
CF451-8CF451-8
CF451-8
CF451-8
Formed Aluminum TrimFormed Aluminum Trim Aluminum Trim
CF450-20
CF451-21
CF451-8
CF451-8
3 4
31/16"13/16"
4 1/2"
FRAME WIDTH
D.L.O.
135º
45º
CF450-21
CF450-20
Varies
KEY ELEVATION
190º 90º
2
3135º 45º
4
41/2"41/2"
FRAME WIDTH
D.L.O.
41 / 2"
90º
CF451-8CF451-8
CF451-8 CF451-8
CORNER DETAILS
40 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
CD100-8
2"11 / 8
"
31 / 8"
DLO
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
1 / 4"
2"
DLO
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
2"
1 / 4"
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G 2"
4
4
3
2
2
3A
1
DLO
FRA
ME
HE
IGH
T
MAS
ON
RY
OPE
NIN
G
41/2"
1 / 4"
2"
CF200-5 CF200-4
CF451-32
COC COC
CF200-1
CF451-32
CF200-1
CF200-6-1
CD100-8
T450T450
CF200-8
CF451-31
CF200-8
ENTRANCEKEY ELEVATION
1
3
2
1
3A
2
3
4
3A
4
CF451-2CF451-3
CF451-311" Insulated Glass
1" Insulated Glass
CD100-2
HORIZONTAL OFFSET PIVOT HUNG DOORFRAME DETAILS
Effective October 2014 www.cardcompro.com 41
SERIES CF451T 2” x 41/2” - B2
DOOR OPENING
5 CF200-6-1T450
D.L.O.D.L.O.
FRAME WIDTH
MASONRY OPENING
2"
1
CF451-30CF451-4
GSK-1(Typ)
D.L.O. DOOR OPENING
FRAME WIDTH
MASONRY OPENING
DOOR OPENING
1/4"FRAME WIDTH
MASONRY OPENING
2"
3
CF451-30
CF200-8
CF451-4
GSK-1(Typ)
D.L.O.
1/4"FRAME WIDTH
MASONRY OPENING
2"
2
CF451-30
CF450-17
2"
4
CF451-30
CF200-8
CF450-17
GSK-1(Typ)
D.L.O. DOOR OPENING
FRAME WIDTH
MASONRY OPENING
2"
3A
CF451-34
CF200-3
CF451-4
For Offset Pivot DoorframeRequiring Steel Reinforcement
STL-2Steel Reinforcement
ENTRANCEKEY ELEVATION
1 2
33A
3A4
1 2
3 5 4
3 4 3 5 4
CD100-2
1" Insulated Glass
T450
VERTICAL OFFSET PIVOT HUNG DOORFRAME DETAILS
42 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
CD100-8
2"11 / 8
"
31 / 8"
DLO
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
1 / 4"
2"
DLO
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
2"
1 / 4"
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G 2"
4
4
3
2
2
3A
DLO
FRA
ME
HE
IGH
T
MAS
ON
RY
OPE
NIN
G
1 / 4"
2"
CF200-5 CF200-4
CF451-32
COC COC
CF200-1
CF451-32
CF200-1
CF200-6-1
CD100-8
T450T450
CF200-8
CF451-31
CF200-8
CF451-13
1
41/2"
ENTRANCEKEY ELEVATION
1
3
2
1
3A
2
3
4
3A
4
CF451-311" Insulated Glass
1" Insulated Glass
CD100-2
HORIZONTAL OFFSET BUTT HUNG DOORFRAME DETAILS
Effective October 2014 www.cardcompro.com 43
SERIES CF451T 2” x 41/2” - B2VERTICAL OFFSET BUTT HUNG DOORFRAME DETAILS
DOOR OPENING
5 CF200-6-1T450
D.L.O. DOOR OPENING
FRAME WIDTH
MASONRY OPENING
DOOR OPENING
1/4"FRAME WIDTH
MASONRY OPENING
2"
3
CF451-34
CF200-3
CF451-4
GSK-1(Typ)
CF200-4
CF200-5
CF200-4
CF200-5
CF451-4
CF200-17
2"
D.L.O. DLO
FRAME WIDTH
MASONRY OPENING
31/8"
11/8"
31/8"
2"11/8"
DLO
1/4"FRAME WIDTH
MASONRY OPENING
65CF451-34CF451-34
GSK-1(Typ)
2"
4
CF451-34
CF200-3
CF450-17
ENTRANCEKEY ELEVATION
1 2
3 4
1 2
3 5 4
3 4 3 5 4
CD100-2
1" Insulated Glass
44 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
1" Insulated Glass
CD100-2
4
7 8
3
2
2"D.L.O. DOOR OPENING
FRAME WIDTH
MASONRY OPENING
2" DOOR OPENING
1/4"FRAME WIDTH
MASONRY OPENING
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
2"11 / 8
"
31 / 8"
D.L
.O.
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
CF200-4
CF200-5
CF200-4
CF200-5
CF451-4
CF200-17
2"
D.L.O. DLO
FRAME WIDTH
MASONRY OPENING
31/8"
11/8"
31/8"
2"11/8"
DLO
1/4"FRAME WIDTH
MASONRY OPENING
65
CF451-4
CF450-17
13 / 4"
DO
OR
OP
EN
ING
1 / 4"
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
1
DLO
FRA
ME
HE
IGH
T
MAS
ON
RY
OPE
NIN
G
41/2"
2"
1 / 4"
CF451-33
CF450-34
CF451-33
CF450-34
CF451-35CF451-35CF451-35
CF451-35
T450
DOOR OPENING
9 T450
T450
ENTRANCEKEY ELEVATION
1
3
27 8
5 6 6 6
8 9 8
7 88 9 8
1
3
2
3
4
3
4
Opp
Opp
Opp
COC
COC
GSK-1(Typ)
CF451-13
CF200-5 CF200-4
CENTER PIVOT HUNG DOORFRAME DETAILS
Effective October 2014 www.cardcompro.com 45
SERIES CF451T 2” x 41/2” - B2
12"
1 / 4"
DLO
FRA
ME
HE
IGH
T
MA
SO
NR
Y O
PE
NIN
G
MU
LLIO
N L
EN
GTH
41/2"
FRA
ME
HE
IGH
T
MA
SO
NR
Y O
PE
NIN
G
MU
LLIO
N L
EN
GTH
FRAME WIDTH
FRAME OPENING
FRAME WIDTH
7
2"D.L.O. D.L.O.1/4" 1/4"
41 / 2"
CF451-13
2"
41/2"
CF450-11
CF450-11
CF450-17
41 / 2"
CF451-30
CF200-8
FRAME WIDTH
FRAME OPENING
FRAME WIDTH
8
2" D.L.O. 1/4" 1/4"
CF451-13
2"
41/2"
DOOR OPENING
CF450-17CF450-11
CF450-11
5
2" DLO
1/4"
41 / 2"
CF451-13
FRAME WIDTH
MASONRY OPENING
6
1/2"Butt Joint
Structural Silicone
KEY ELEVATION
8 8Opp. Opp.
3
4
1A1
2
5 56
2
1
6
7 7Opp.
22"
7 / 16"
11/ 16
"
1 / 4"
DLO
CF451-13
CF451-6
CF451-30
GSK-1(Typ)
DO
OR
OP
EN
ING
FRA
ME
WID
TH a
t DO
OR
MA
SO
NR
Y O
PE
NIN
G
4CD100-8
T450
3
1A
GSK-1(Typ)
1 / 2"CF200-6-1
DLO
DO
OR
OP
EN
ING
FRA
ME
WID
TH
MA
SO
NR
Y O
PE
NIN
G
2"
CF200-8
CF451-31 CF451-13
CF451-18
CF451-18
CF451-18
DLO
FRA
ME
HE
IGH
T
MAS
ON
RY
OPE
NIN
G
41/2"
1 / 4"
2"
CF451-2CF451-3
T450
BUTT GLAZED FRAMING with OFFSET PIVOT HUNG ENTRANCE DETAILS
BUTT GLAZING NOTE:●Glassthicknessatsidelights=1/2"●Glassbiteatsidelights=1/2" 1/2"GlassshownwithCF451 framing, 1" Insulated Glass with CF451T framing is similar.●UseGSK-1gasket
46 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B21" GLASS to 1/4" GLASS TRANSITIONS
1
3
2
4
5
6A7 8 96
2" 2" 2" 2" 2"D.L.O. D.L.O. D.L.O. D.L.O.
FRAME WIDTH
MASONRY OPENING
2"2"
2"2"
D.L
.O.
D.L
.O.
2"D
.L.O
.D
.L.O
.
FRA
ME
HE
IGH
T
MA
SO
NR
Y O
PE
NIN
G
MU
LLIO
N L
EN
GTH
1 / 4"
1 / 4"
1 / 2"
3 / 4"
1/4"1/4"
KEY ELEVATION
6 8 9 8
1
2
5
4
5
1
3
9 7 6A
CF451-13T
CF451-4T
CF451-1T
CF451-4T CF451-4T
CF451-1TCF451-1T
CF451-13T
CF451-2TCF451-3
CF451-2TCF451-3
CF451-2TCF451-3
CF451-2TCF451-3 CF451-6T
CF451-15
CF451-15
CF451-15
CF451-15 CF451-15 CF451-15
CF451-1T
Optional Jamb
CF451-17T
Effective October 2014 www.cardcompro.com 47
SERIES CF451T 2” x 41/2” - B2WIND LOAD CHARTS
THIS PAGE INTENTIONALLY LEFT BLANK
48 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
18 22 26 30 34 38 42 46 50 54 58 62 66 70 7490
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
CF451-5/CF451-4CF451-7/CF451-8
CF451-1/CF451-4
CF451 @ 20 PSF
W
H
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
EXAMPLE ELEVATION
H = Mullion HeightW = Mullion Spacing
CF451-4
CF451-4
CF451-1
CF451-5
CF451-7 CF451-8
CurvesarebasedondeflectionlimitedtoL/175nottoexceed1" and total lateral support of flanges.
WIND LOAD CHARTS(Assumes Total Lateral Support of flanges)
Effective October 2014 www.cardcompro.com 49
SERIES CF451T 2” x 41/2” - B2
18 22 26 30 34 38 42 46 50 54 58 62 66 70 7440
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
CF451-5/CF451-4CF451-7/CF451-8
CF451-1/CF451-4
W
H
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
EXAMPLE ELEVATION
H = Mullion HeightW = Mullion Spacing
CF451-4
CF451-4
CF451-1
CF451-5
CF451-7 CF451-8CF451 @ 30 PSF
CurvesarebasedondeflectionlimitedtoL/175nottoexceed1" and total lateral support of flanges.
WIND LOAD CHARTS(Assumes Total Lateral Support of flanges)
50 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
18 22 26 30 34 38 42 46 50 54 58 62 66 70 7440
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
CF451-5/CF451-4CF451-7/CF451-8
CF451-1/CF451-4
W
H
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
EXAMPLE ELEVATION
H = Mullion HeightW = Mullion Spacing
CF451-4
CF451-4
CF451-1
CF451-5
CF451-7 CF451-8CF451 @ 40 PSF
CurvesarebasedondeflectionlimitedtoL/175nottoexceed1" and total lateral support of flanges.
WIND LOAD CHARTS(Assumes Total Lateral Support of flanges)
Effective October 2014 www.cardcompro.com 51
SERIES CF451T 2” x 41/2” - B2
18 22 26 30 34 38 42 46 50 54 58 62 66 70 7420
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
CF451-5/CF451-4CF451-7/CF451-8
CF451-1/CF451-4
W
H
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
EXAMPLE ELEVATION
H = Mullion HeightW = Mullion Spacing
CF451-4
CF451-4
CF451-1
CF451-5
CF451-7 CF451-8CF451 @ 50 PSF
CurvesarebasedondeflectionlimitedtoL/175nottoexceed1" and total lateral support of flanges.
WIND LOAD CHARTS(Assumes Total Lateral Support of flanges)
52 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
SP = 120"
SP = 96"
SP = 72"
SP = 60"SP = 48"
CF451-1/CF451-4 @ 20 PSF
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
CF451-4CF451-1
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 53
SERIES CF451T 2” x 41/2” - B2
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4CF451-1
SP = 120"SP = 96"
SP = 72"
SP = 60"SP = 48"
CF451-1/CF451-4 @ 30 PSF
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
54 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
SP = 120"SP = 96"
SP = 72"
SP = 60"SP = 48"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4CF451-1
CF451-1/CF451-4 @ 40 PSF
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 55
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
SP = 120"SP = 96"
SP = 72"
SP = 60"SP = 48"
CF451-1/CF451-4 @ 50 PSF
CF451-4CF451-1
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
56 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
CF451-5/CF451-4 @ 20 PSF
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
SP = 120”
SP = 96”
SP = 72”
SP = 48”
SP = 24”
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
CF451-4CF451-5
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 57
SERIES CF451T 2” x 41/2” - B2
CF451-5/CF451-4 @ 30 PSF
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
SP = 120"
SP = 96"
SP = 72"
SP = 60"
SP = 48"SP = 24"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4CF451-5
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
58 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
CF451-5/CF451-4 @ 40 PSF
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
SP = 120"
SP = 96"
SP = 72"
SP = 60"
SP = 48"SP = 24"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4CF451-5
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 59
SERIES CF451T 2” x 41/2” - B2
CF451-5/CF451-4 @ 50 PSF
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
SP = 120"SP = 96"
SP = 72"
SP = 60"
SP = 48"
SP = 24"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-4CF451-5
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
60 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
CF451-7/CF451-8 @ 20 PSF
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74SP = 120"SP = 96"
SP = 72"
SP = 60"
SP = 48"
SP = 24"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200CF451-7 CF451-8
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 61
SERIES CF451T 2” x 41/2” - B2
CF451-7/CF451-8 @ 30 PSF
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
SP = 120"SP = 96"
SP = 72"
SP = 60"
SP = 48"
SP = 24"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-7 CF451-8
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
62 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
CF451-7/CF451-8 @ 40 PSF
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
SP = 120"SP = 96"
SP = 72"
SP = 60"
SP = 48"
SP = 24"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-7 CF451-8
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
Effective October 2014 www.cardcompro.com 63
SERIES CF451T 2” x 41/2” - B2
CF451-7/CF451-8 @ 50 PSF
18 22 26 30 34 38 42 46 50 54 58 62 66 70 74
SP = 120"SP = 96"
SP = 72"SP = 60"
SP = 48"
SP = 24"
Mullion Spacing in (Inches)
Mul
lion
Hei
ght i
n (In
ches
)
H = Mullion HeightW = Mullion SpacingSP = Maximum Horizontal Space (Largest Space between Horizontals)
EXAMPLE ELEVATION
HSP
W
CF451-7 CF451-8
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H) of the opening,thewidth(W) of the mullion spacingandthemaximumspacing(SP) of the horizontals.
Thismullionisacceptableifthe horizontal mullions do not exceedspacing(SP)basedonAASpecificationforAluminumStructures, 2010.
WIND LOAD CHARTS
64 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
Mullion Spacing in (Inches)
Hor
izon
tal S
paci
ng in
(Inc
hes)
54 57 60 63 66 69 72 75 78 81 84 87 90 93 960
25
50
75
100
125
150
175
200
x = 1/4x = 1/8
EXAMPLE ELEVATION
CF451-2 with 1" Glass
H = Distance between HorizontalsW = Mullion Spacingx = Location of setting blocks as a fraction of W
NOTE: Curves are based on deflection limited to 1/8”.
W W
W/xSetting BlockLocation
W WH
CF451-2CF451-3
These charts are designed to help with the selection of a mullion for storefront applicationsgiventheheight(H)oftheglassandthewidth(W)ofthemullionspacing.
DEAD LOAD CHARTS
Effective October 2014 www.cardcompro.com 65
SERIES CF451T 2” x 41/2” - B2Cardinal Commercial Products
ALUMINUM STOREFRONT SYSTEMSERIES CF451 (Non Thermal)GUIDE SPECIFICATIONS
SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS
This suggested guide specification has been developed using the current edition of the Construction Specifications Institute (CSI) “Manual of Practice,” including the recommendations for the CSI 3 Part Section Format and the CSI Page Format. The developmental concept and organizational arrangement used by the American Institute of Architects (AIA) MASTERSPEC Program were recognized in the preparation of this guide specification. Neither CSI nor AIA endorse specific manufacturers and products. The preparation of the guide specification assumes the use of standard contract documents and forms, including the “Conditions of the Contract,” published by the AIA.
PART 1 – GENERAL
1.01 Summary A. Section Includes: Architectural Aluminum Products by CARDINAL COMMERCIAL PRODUCTS, including perimeter trims, stools, accessories, shims and anchors, and perimeter sealing of storefront framing. 1. Types of Architectural Aluminum Products by CARDINAL COMMERCIAL PRODUCTS include: a. CF451:2”x4-1/2”(outside)or(inside)centerglazedstorefrontsystemfor1”insulatedglazing.
EDITOR NOTE: BELOW RELATED SECTIONS ARE SPECIFIED ELSE WHERE, HOWEVER, CARDINAL COMMERCIAL PRODUCTS RECOMMENDS SINGLE SOURCE RESPONSIBILITY FOR ALL OF THESE SECTIONS AS INDICATED IN 2.07 SOURCE QUALITY CONTROL.
B. Related Sections: 1. Division7Section“VaporBarriers”betweenglazedwallsystemsandadjacentconstruction 2. Division7Section“FireStopping” 3. Division7Section“JointSealants”forjointsealantsinstalledaspartofaluminumentranceandstorefrontsystem 4. Division8Section“GlazedAluminumCurtainWalls” 5. Division8Section“AluminumWindowsWalls” 6. Division8Section“AluminumEntrancesandStorefronts” 7. Division8Section“AluminumMallSlidingDoors” 8. Division8Section“FinishHardware” 9. Division8Section“GlassandGlazing”
EDITOR NOTE: REFER TO INDEX FOR ANY AND ALL APPLICABLE STANDARDS.
1.02 References(IndustryStandards)
1.03 System Description A.StorefrontSystemPerformanceRequirements: 1. AirInfiltration:ThetestspecimenshallbetestedinaccordancewithASTM283.Airinfiltrationrateshallnotexceed0.06cfm/ft2ata(static) air pressure differential of 6.24 PSF. 2. WaterResistance,(static):ThetestspecimenshallbetestedinaccordancewithASTM331for(outside)or(inside).Thereshallbenoleakage ataminimumstaticairpressuredifferentialof10PSFasdefinedinAAMA501. 3. UniformLoad:Astaticairdesignloadof35PSFshallbeappliedinthepositiveandnegativedirectioninaccordancewithASTME330.Thereshall benodeflectioninexcessofL/175ofthespanofanyframingmemberatdesignload.Atstructuraltestloadequalto1.5timesthespecified designload,noglassbreakageorpermanentsetintheframingmembersinexcessof0.2%oftheirclearspansshalloccur.
1.04 Submittals A.General:Prepare,review,approve,andsubmitspecifiedsubmittalsinaccordancewith“ConditionsoftheContract”andDivision1SubmittalsSections. Productdata,shopdrawings,samples,andsimilarsubmittalsaredefinedin“ConditionsoftheContract.” B.QualityAssurance/ControlSubmittals: 1. TestReports:Submitcertifiedtestreportsshowingcompliancewithspecifiedperformancecharacteristics.
1.05 Warranty A.ProjectWarranty:Referto“ConditionsoftheContract”forprojectwarrantyprovisions. B.Manufacturer’sProductWarranty:Submit,forOwner’sacceptance,manufacturer’swarrantyforstorefrontsystemasfollows: 1. WarrantyPeriod:Two(2)yearsfromDateofSubstantialCompletionoftheproject.TheLimitedWarrantyshallbegininnoeventlaterthansix months fromdate of shipment byCARDINAL COMMERCIAL PRODUCTSwithout regard to the date selected as substantial completion. In addition, entrance door corner construction shall be supported with a lifetime warranty for the life of the door under normal use.
1.06 Quality Assurance A.Qualifications: 1. InstallerQualifications:Installerexperienced(asdeterminedbycontractor)toperformworkofthissectionwhohasspecializedintheinstallation ofworksimilartothatrequiredforthisprojectandwhoisacceptabletoproductmanufacturer. 2. ManufacturerQualifications:Manufacturercapableofprovidingfieldservicerepresentationduringconstruction,approvingacceptableinstaller and approving application method. B.Pre-Installation Meetings: Conduct pre-installation meeting to verify project requirements, substrate conditions, manufacturer’s installation instructions,andmanufacturer’swarrantyrequirements.
S1
66 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
GUIDE SPECIFICATIONS(Continued)
1.07 Delivery, Storage, and Handling A.Ordering:Complywithmanufacturer’sorderinginstructionsandschedulingrequirementstoavoidconstructiondelays. B.Packing,Shipping,Handling, andUnloading:Delivermaterials inmanufacturer’s original, unopened, undamagedcontainerswith identification labelsintact. C.StorageandProtection:Storematerialsprotectedfromexposuretoharmfulweatherconditions.Handlestorefrontmaterialandcomponentstoavoid damage.Protectstorefrontmaterialagainstdamagefromelements,constructionactivities,andotherhazardsbefore,duringandafterstorefront installation.
PART 2 – PRODUCTS
EDITOR NOTE: RETAIN BELOW ARTICLE FOR PROPRIETARY METHOD SPECIFICATION; ADD PRODUCT ATTRIBUTES, PERFORMANCE CHARACTERISTICS, MATERIAL STANDARDS, AND DESCRIPTIONS AS APPLICABLE. DO NOT USE THE PHRASE “OR EQUAL” / “OR APPROVED EQUAL,” OR SIMILAR PHRASES, USE OF SUCH PHRASES CAN CAUSE AMBIGUITY IN THE SPECIFICATIONS DUE TO THE DIFFERENT INTERPRETATIONS AMONG THE DIVERGENT PARTIES OF THE CONSTRUCTION PROCESS AND READERS OF THESE SPECIFICATIONS. SUCH PHRASES REQUIRE EXTENSIVE AND COMPLETE REQUIREMENTS (PROCEDURAL, LEGAL, REGULATORY, AND RESPONSIBILITY) FOR DETERMINING “OR EQUAL.”
2.01 Manufacturers(AcceptableManufacturers/Products) A.AcceptableManufacturers: 1. Address: Cardinal Commercial Products, LLC 4915 Heller Street Louisville, KY 40218 Contact Numbers: a. Telephone: 502-969-4059 b.Fax:502-813-2484 c. Email: [email protected] d.Webaddress:cardcompro.com 2. ProprietaryProduct(s)/System(s):CARDINALCOMMERCIALPRODUCTS a. Series: CF451 Storefront System EDITOR NOTE: RETAIN BELOW FOR ALTERNATE MANUFACTURERS/PRODUCTS AS SPECIFIED IN THE CONTRACT DOCUMENTS. COORDINATE BELOW WITH BID DOCUMENTS (IF ANY), AND DIVISION 1 ALTERNATES SECTION. CONSULT WITH CARDINAL COMMERCIAL PRODUCTS FOR RECOMMENDATIONS ON ALTERNATE MANUFACTURERS AND PRODUCTS MEETING THE DESIGN CRITERIA AND PROJECT REQUIREMENTS. CARDINAL COMMERCIAL PRODUCTS RECOMMENDS OTHER MANUFACTURERS REQUESTING APPROVAL TO BID THEIR PRODUCT AS AN EQUAL, MUST SUBMIT THEIR REQUEST IN WRITING (10) DAYS PRIOR TO CLOSE OF BIDDING. b. Finish/Color:(See2.06Finishes) c. FramingMemberProfile:2”x4-1/2”nominaldimension;CenterGlazed;ScrewSplineFabrication Provide combination full height subsill receptor and sill section which eliminate blind seal conditions at fasteners penetrating subsillreceptor.Subsillreceptortohavefullheightenddamsandweepholesbackedwithbafflestoreduceairinfiltration. B.Alternate (Manufacturers/Products): In lieu of providing below specified base bid/contract manufacturer, provide below specified alternate manufacturers. Refer to Division 1 Alternates Section. 1. BaseBid/ContractManufacturer/Product:CARDINAL COMMERCIAL PRODUCTS a. Product: Aluminum Storefront System b. Series CF451StorefrontSystem:2”x4-1/2”nominaldimension,CenterGlazed;Screw-SplineFabrication 2. Alternate#____Manufacturer/Product: a. Product: b. Series: c. FramingMemberProfile: 3. Alternate#___Manufacturer/Product: a. Product: b. Series: c. FramingMemberProfile: C.Substitutions: 1. General:RefertoDivision1Substitutionsforproceduresandsubmissionrequirements. a. Pre-Contract(BiddingPeriod)Substitutions:Submitwrittenrequeststen(10)dayspriortobiddate. b. Post-Contract(ConstructionPeriod)Substitutions:Submitwrittenrequestinordertoavoidstorefrontinstallationandconstructiondelays. 2. SubstitutionDocumentation a. ProductLiteratureandDrawings:Submitproductliteratureanddrawingsmodifiedtosuitspecificprojectrequirementsandjobconditions. b. Certificates:Submitcertificate(s)certifyingsubstitutemanufacturer(1)attestingtoadherencetospecificationrequirementsforstorefrontsystem performance criteria. c. TestReports:Submittestreportsverifyingcompliancewitheachtestrequirementforstorefrontrequiredbytheproject. d. ProductSampleandFinish:Submitproductsample,representativeofstorefrontfortheproject,withspecifiedfinishandcolor. 3. SubstitutionAcceptance:Acceptancewillbeinwrittenform,eitherasanaddendumormodification,anddocumentedbyaformalchangeordersignedby the Owner and Contractor.
S2
Effective October 2014 www.cardcompro.com 67
SERIES CF451T 2” x 41/2” - B2
GUIDE SPECIFICATIONS(Continued)
2.02 Materials A.Aluminum(StorefrontandComponents): 1. MaterialStandard:ExtrudedAluminum,A96063-T6and/orA95050-H32alloyandtemper. 2. MemberWallThickness:Eachframingmembershallhaveawallthicknesssufficienttomeetthespecifiedstructuralrequirements. 3. Tolerances:Referencetotolerancesforwallthicknessandothercross-sectionaldimensionsofstorefrontframingmembersarenominalandin compliance with AA Aluminum Standards and Data.
2.03 Accessories A.Fasteners:Whereexposed,shallbeStainlessSteel. B.Gaskets:GlazinggasketsshallcomplywithASTMC864andbeextrudedofsiliconecompatibleEPDMrubberthatprovidesforsiliconeadhesion. C.PerimeterAnchors:Whensteelanchorsareused,provideinsulationbetweensteelmaterialandaluminummaterialtopreventgalvanicaction.
2.04 Related Materials A.Sealants:RefertoJointTreatment(Sealants)Section. B. Glass: Refer to Glass and Glazing Section.
2.05 Fabrication A. General: 1. Fabricate components per manufacturer’s installation instructions and with minimum clearances and shim spacing around perimeter of assembly,yetenablinginstallationanddynamicmovementofperimeterseal. 2. Accuratelyfitandsecurejointsandcorners.Makejointsflush,hairlineandweatherproof. 3. Arrange fasteners and attachments to conceal from view.
EDITOR NOTE: SELECT BELOW FINISH AND COLOR FROM CARDINAL COMMERCIAL PRODUCTS’S STANDARD COLORS. CUSTOM COLORS ARE AVAILABLE UPON REQUEST FROM CARDINAL COMMERCIAL PRODUCTS. OTHER POLYESTER POWDER COATINGS CONFORMING TO AAMA 2604 ARE AVAILABLE. CONSULT WITH YOUR CARDINAL COMMERCIAL PRODUCTS REPRESENTATIVE FOR OTHER SURFACE TREATMENTS AND FINISHES.
2.06 Finishes A. Shop Finishing 1. ColorAnodizingConformingtoAA-M12C22A44,AAMA611,Architectural.Class.I.AnodicCoating(Color:#21DarkBronze).(Standard) 2. ClearAnodizingConformingtoAA-M12C22A31,AAMA611,Architectural.Class.II.ClearAnodicCoating(Clear:#11(Standard) 3. AAMA2605,FluoropolymerPowderCoating(Color:__________). 4. AAMA2604,PolyesterPowderCoating.(Color:__________). 5. Other:Manufacturer____________Type____________Color:__________).
2.07 Source Quality Control A.SourceQuality:Providealuminumstorefrontspecifiedhereinfromasinglesource. 1. BuildingEnclosureSystem:Whenaluminumcurtainwall arepart of abuildingenclosure system, includingentrances,entrancehardware, windows,curtainwallframingandrelatedproducts,providebuildingenclosuresystemproductsfromasinglesourcemanufacturer.
PART 3 – EXECUTION
3.01 Examination A.SiteVerificationofConditions:Verifysubstrateconditions(whichhavebeenpreviouslyinstalledunderothersections)areacceptableforproduct installationinaccordancewithmanufacturer’sinstructions.Verifyopeningsaresizedtoreceivespecifiedsystemandsillplateislevelinaccordance withmanufacturer’sacceptabletolerances.
EDITOR NOTE: COORDINATE BELOW ARTICLE WITH MANUFACTURER’S RECOMMENDED INSTALLATION DETAILS AND INSTALLATION INSTRUCTIONS.
1. FieldMeasurements:Verifyactualmeasurements/openingsbyfieldmeasurementsbeforefabrication;showrecordedmeasurementsonshop drawings.Coordinatefieldmeasurements,fabricationschedulewithconstructionprogresstoavoidconstructiondelays.
3.02 Installation A.General: Installstorefrontsystemsplumb, level,andtrueto line,withoutwarporrackof frameswithmanufacturer’sprescribedtolerancesand installation instructions. Provide support and anchor in place. 1. DissimilarMaterials:Provideseparationofaluminummaterialsfromsourcesofcorrosionorelectrolyticactioncontactpoints. 2. Glazing:Glassshallbe(outside)or(inside)glazedandheldinplacewithextrudedEPDMglazinggasketsonbothsidesoftheglass. 3. Water Drainage: Waterdeflectorsshallbeinstalledateachendofintermediatehorizontalallowinginfiltratedwatertodraindownthe verticalmember’sglazingpocketintoafullheightsubsillreceptorwhereitweepstotheexteriorthroughaseriesoffactorypunched weepholesbackedwithbafflestoreduceairinfiltration. B.RelatedProductsInstallationRequirements: 1. Sealants(Perimeter):RefertoDivision7JointTreatment(Sealants)Section. 2. Glass: Refer to Division 8 Glass and Glazing Section. a.Reference:ANSIZ97.1,CPSC16CFR1201andGANAGlazingManual
S3
68 www.cardcompro.com Effective October 2014
SERIES CF451T 2” x 41/2” - B2
GUIDE SPECIFICATIONS(Continued)
3.03 Field Quality Control A.FieldTests:Architectshallselectstorefrontunitstobetestedassoonasarepresentativeportionoftheprojecthasbeeninstalled,glazed,perimeter caulkedandcured.Conducttestsforairinfiltrationandwaterpenetrationwithmanufacturer’srepresentativepresent.Testsnotmeetingspecified performancerequirementsandunitshavingdeficienciesmustbecorrectedaspartofthecontractamount. 1. Testing:TestingshallbeperformedperAAMA503byaqualifiedindependenttestingagency.RefertoDivisionTestingSectionforpaymentoftesting andtestingrequirements. a.AirInfiltrationTests:ConducttestsinaccordancewithASTME783.Allowableairinfiltrationshallnotexceed1.5timestheamountindicatedin theperformancerequirementsor0.09cfm/ft2,which,everisgreater. b. WaterInfiltrationTests:ConducttestsinaccordancewithASTME1105.Nouncontrolledwaterleakageispermittedwhentestedatastatictest pressureoftwo-thirdsthespecifiedwaterpenetrationpressurebutnotlessthan8PSF. B.Manufacturer’sFieldServices:UponOwner’srequest,providemanufacturer’sfieldserviceconsistingofproductuserecommendationsandperiodic sitevisitforinspectionofproductinstallationinaccordancewithmanufacturer’sinstructions.
3.04 Protection and Cleaning A.Protection:Protect installedproduct’sfinishsurfaces fromdamageduringconstruction.Protectaluminumstorefrontsystemfromdamage from grinding and polishing compounds, plaster, lime, acid, cement, or other harmful contaminants.
B.Cleaning:Repairorreplacedamagedinstalledproducts.Installedproductsaretobecleanedinaccordancewithmanufacturer’sinstructionsprior toowner’sacceptance.Removeconstructiondebrisfromprojectsiteandlegallydisposeofdebris.
DISCLAIMER STATEMENTThis guide specification is intended for useby a qualified construction specifier.Theguide specification is not intended to be verbatimas a project specificationwithoutappropriatemodificationsforthespecificuseintended.Theguidespecificationmustbeusedandcoordinatedwiththeproceduresofeachdesignfirm,andtheparticularrequirementsofaspecificconstructionproject.
END OF SECTION 08410