series q-03 eries q-03 series q- 03 series q-03 eries q-03 ......120 vac nominal 12 vdc response...
TRANSCRIPT
–––––
series Q-03
relief valve
536 TOWNSHIP LINE ROAD FLUID TECHNOLOGY ANNEX BLUE BELL, PENNSYLVANIA 19422 Tel: 215.643.0617 Fax: 216.643.4017 [email protected] www.doubleahydraulics.com
www.doubleahydraulics.com
–––––
series Q-03 directional control
valve
536 TOWNSHIP LINE ROADFLUID TECHNOLOGY ANNEXBLUE BELL, PENNSYLVANIA 19422Tel: 215.643.0617Fax: [email protected]
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
®
© 2019 Double A Hydraulics All rights reserved.
6100 psi, 30 Gpm maxpilot operated spool type
–––––
series Q-03
relief valve
536 TOWNSHIP LINE ROAD FLUID TECHNOLOGY ANNEX BLUE BELL, PENNSYLVANIA 19422 Tel: 215.643.0617 Fax: 216.643.4017 [email protected] www.doubleahydraulics.com
www.doubleahydraulics.com
–––––
series Q-03 directional control
valve
536 TOWNSHIP LINE ROADFLUID TECHNOLOGY ANNEXBLUE BELL, PENNSYLVANIA 19422Tel: 215.643.0617Fax: [email protected]
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
®
© 2019 Double A Hydraulics All rights reserved.
6100 psi, 30 Gpm maxpilot operated spool type
–––––
series Q-03
relief valve
536 TOWNSHIP LINE ROAD FLUID TECHNOLOGY ANNEX BLUE BELL, PENNSYLVANIA 19422 Tel: 215.643.0617 Fax: 216.643.4017 [email protected] www.doubleahydraulics.com
www.doubleahydraulics.com
–––––
series Q-03 directional control
valve
536 TOWNSHIP LINE ROADFLUID TECHNOLOGY ANNEXBLUE BELL, PENNSYLVANIA 19422Tel: 215.643.0617Fax: [email protected]
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
®
© 2019 Double A Hydraulics All rights reserved.
6100 psi, 30 Gpm maxpilot operated spool type
–––––
series Q-03
relief valve
536 TOWNSHIP LINE ROAD FLUID TECHNOLOGY ANNEX BLUE BELL, PENNSYLVANIA 19422 Tel: 215.643.0617 Fax: 216.643.4017 [email protected] www.doubleahydraulics.com
www.doubleahydraulics.com
–––––
series Q-03 directional control
valve
536 TOWNSHIP LINE ROADFLUID TECHNOLOGY ANNEXBLUE BELL, PENNSYLVANIA 19422Tel: 215.643.0617Fax: [email protected]
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
®
© 2019 Double A Hydraulics All rights reserved.
6100 psi, 30 Gpm maxpilot operated spool type
MAXIMUM OPERATING PRESSURE
RELATED FLOW CAPACITY
MOUNTING BOLTS
P,A,B PORTS
T PORT
P,A,B T PORTS
10-24 X 2” 45-60 inch-#
4500 psi
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
VALVE INTERFACE
03- NFPA D03
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (D
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
®
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS. SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATING PRESSURE
RATED FLOW CAPACITY
MOUNTING BOLTS
VISCOSITY RANGE
TEMPERATURE RANGE
FLUID CLEANLINESS
WEIGHT
P,A,B PORTS
T PORT
P,A,B,T PORTS
10-24 X 2” 45-60 inch-#
60-1800 SSU -13 TO 194F Better than NAS 12
4500 psi
3000 psi 16 gpm
Single Solenoid 3.5 lbs
Double Solenoid 4.4 lbs
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POS. SPRING CENTERED, SOL. AQJF- 2 POS. SPRING CENTERED, SOL. B DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RATEDFLOWCAPACITY
MOUNTINGBOLTS
VISCOSITYRANGE
TEMPERATURERANGE
FLUIDCLEANLINESS
WEIGHT
P,A,BPORTS
TPORT
P,A,B,TPORTS
10-24 X 2” 45-60 inch-#
60-1800 SSU -22 TO 176F Better than NAS 12
Single Solenoid3.5 lbs
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)Double Solenoid4.6 lbs
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. A
ELECTRICAL CONNECTION
DN- DIN HIRSCHMANNDT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
SOLENOID COILS120 VAC Nominal 12 VDC Response Time (ms) Switching
FrequencyIntrusionProtection
MaximumSurface Temp
50 Hz
60 Hz
99-121 VAC
108-132 VAC
10.8-13.2 VDC
30 WAC
DC
On10-20
25-45
Off15-40
10-25
AC
DC
7,200 cycles/hr15,000 cycles/hr
ConnectorDIN (DN)
DEUTSCH (DT)
IP 65
IP 69
AC
DC
350 F
300 F
Q*-03-A-***-*-**-***
SPOOL SPRING COIL VOLTAGEARRANGEMENT
A120- 120 VAC 50/60 HZQF- 3 POS. SPRING CENTERED D12- 12VDCQG- 2 POS. SPRING OFFSET, SOL. AQF- 3 POS. SPRING CENTEREDQJ- 2 POS. SPRING OFFSET, SOL. B ELECTRICAL CONNECTIONQGF- 2 POQJF- 2 PO DN- DIN HIRSCHMANN
DT- DEUTSCH
VALVE INTERFACE SEAL OPTION
03- NFPA D03 BUNAVITON
DESIGN CODE
SPOOL FUNCTION AND TYPE(SEE CHART ON NEXT PAGE)
MAXIMUM OPERATINGPRESSURE
RELATEDFLOWCAPACITY
MOUNTINGBOLTS
P,A,BPORTS
TPORT
P,A,B TPORTS
10-24 X 2”45-60 inch-#
4500 psi 2300 psi 21 gpm (DC)
16 gpm (AC)
Series Q-03directional control
valve
Specifications
Ordering Information
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
20/18/15Or Better
(ISO 4460)
series Q-03
directional controlvalve
legacy
www.doubleahydraulics.com © 2019 Double A Hydraulics All rights reserved.
–––––
series Q-03
relief valve
536 TOWNSHIP LINE ROAD FLUID TECHNOLOGY ANNEX BLUE BELL, PENNSYLVANIA 19422 Tel: 215.643.0617 Fax: 216.643.4017 [email protected] www.doubleahydraulics.com
www.doubleahydraulics.com
–––––
series Q-03 directional control
valve
536 TOWNSHIP LINE ROADFLUID TECHNOLOGY ANNEXBLUE BELL, PENNSYLVANIA 19422Tel: 215.643.0617Fax: [email protected]
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
®
© 2019 Double A Hydraulics All rights reserved.
6100 psi, 30 Gpm maxpilot operated spool type
–––––
series Q-03
relief valve
536 TOWNSHIP LINE ROAD FLUID TECHNOLOGY ANNEX BLUE BELL, PENNSYLVANIA 19422 Tel: 215.643.0617 Fax: 216.643.4017 [email protected] www.doubleahydraulics.com
www.doubleahydraulics.com
–––––
series Q-03 directional control
valve
536 TOWNSHIP LINE ROADFLUID TECHNOLOGY ANNEXBLUE BELL, PENNSYLVANIA 19422Tel: 215.643.0617Fax: [email protected]
2014 Double A Hydraulics All rights reserved. www.doubleahydraulics.com
®
© 2019 Double A Hydraulics All rights reserved.
6100 psi, 30 Gpm maxpilot operated spool type
TECHNICAL DATA PRESSURE DROP DATA
DIMENSIONS
ORDERING INFORMATION
Maximum operating pressure 6100 psiMaximum Flow: 30 gpmMaximum leakage: 6 in3/min at 90% of settingOperating Temperature Range: -22F to 230FViscosity: 60-1800 SSU hydraulic oil with lubricating propertiesOrientation: OptionalInstallation Torque: 40-45 foot poundsWeight: 0.43 poundsPressure on port 2 (tank port) is directly additive to the valve setting at a 1:1 ratio.Steel constructionZinc Plated
4 mm HEX
13 mm HEX24 mm HEX
7/8-16 UNF
1.84
1.24
0
1000
2000
3000
4000
5000
6000
7000
8000
0 5 10 15 20 25 30 35
psi
gpm
(Note: Curves shown at maximum setting for each spring)
o1.181o0.943
o0.047 min.
1.65
min
.
o0.625o0
.39
0.943
0.626
0.1
02 0
.114
1.3
4
0.9
45
0.5
91
0.7
09
7/8-14UNF-2B
TYPE RVCP - PILOT OPERATED RELIEF VALVE
CAVITY SAE10
SEALS N - BUNA V - VITON
VALVE SETTING STANDARD SETTING 1500, 2000, 2500, 3000, 4000, 5000 PSI
ADJUSTMENT RANGE X = 300 - 4100 PSI Z = 4100 - 6100 PSI (NON STANDARD RANGE)
RVCP - S10 - N X - 2000