service parts wall mount bath shower faucet...

2
1176570-2A-D 1 BEFORE YOU BEGIN All information is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. Please leave these instructions for the consumer. They contain important information. NOTES: 1. Flush the water supply pipes throughly to remove debris. 2. Observe local plumbing codes. 3. Inspect the supply pipes for damage and leakage. Replace and maintain as necessary 4. The minimum inlet water pressure for the diverter is 0.05MPa(0.5bar). 5. The highest working pressure for handshower is 0.5MPa(5bar). If it exceeds 0.5MPa(5bar), a pressure reducer is needed. The highest water and environment temperature is 60°C. Please keep shower head, handshower and shower arm away from heater, or it may become damaged and cause injury to the user. 45370K-4E2 WALL MOUNT BATH SHOWER FAUCET INSTALLATION INSTRUCTIONS Wall Mount Bath Shower Faucet 45370K-4E2 WALL MOUNT BATH SHOWER FAUCET Wall Mount Bath Shower Faucet HANDLE OPERATION ROUGH-IN DIMENSIONS Lift the handle gently, turn clockwise for hot water, turn counter-clockwise for cold water, bath spout works; turn bath spout clockwise or counter-clockwise, shower works. STRAYT STRAYT 1176570-2A-D 4 SERVICE PARTS **Color code must be specified when ordering 3010697** Nut 3010698 O-ring 871363 O-ring 864985 Seat 1218659 Washer 1161905** Escutcheon 1170944** Connector 1167323** Bonnet 834792 Nut 833438 Screw 1106842** Plug Button 1160487** Handle 834793 Valve 880086 O-ring 1120988 Anchor 1177385** Mounting Bracket 1119427 Screw 1177515 Washer 1177513** Bracket Kit 833730 Hex Wrench 1248781** Hose 1297484** Handshower 1088901 Regulator 77420 Washer 1240266 Check Valve 1285735 Washer 42084 O-ring 1024329 O-ring 91640 O-ring 32725 O-ring 3005148 Aerator 3006148 Key 1276812 Diverter 1285734** Connector Hose Bracket 210 60X60 G1/2˝ 82~92 G1/2˝ 239~249 179 85 Handshower G1/2˝ G1/2˝ 1500 Finished Wall 56 36 56 36 36 81 35° 35° 150±15 90º 90º G1/2˝ 250 28 28 240

Upload: others

Post on 22-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SERVICE PARTS Wall Mount Bath Shower Faucet ...resources.kohler.com/plumbing/kohlerapac/pdf/1176570-2A...shower arm away from heater, or it may become damaged and cause injury to the

1176570-2A-D 1

BEFORE YOU BEGIN

All information is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice.

Please leave these instructions for the consumer. They contain important information.

NOTES:1. Flush the water supply pipes throughly to remove debris.2. Observe local plumbing codes.3. Inspect the supply pipes for damage and leakage. Replace and maintain as necessary4. The minimum inlet water pressure for the diverter is 0.05MPa(0.5bar).5. The highest working pressure for handshower is 0.5MPa(5bar). If it exceeds 0.5MPa(5bar), a pressure reducer is needed. The highest water and environment temperature is 60°C. Please keep shower head, handshower and shower arm away from heater, or it may become damaged and cause injury to the user.

45370K-4E2 WALL MOUNT BATH SHOWER FAUCET

INSTALLATION INSTRUCTIONS Wall Mount Bath Shower Faucet

45370K-4E2 WALL MOUNT BATH SHOWER FAUCET

Wall Mount Bath Shower Faucet

HANDLE OPERATION

ROUGH-IN DIMENSIONS

Lift the handle gently, turn clockwise for hot water, turn counter-clockwise for cold water, bath spout works; turn bath spout clockwise or counter-clockwise, shower works.

STRAYTSTRAYT

1176570-2A-D 4

SERVICE PARTS

**Color code must be specified when ordering

3010697**Nut

3010698O-ring

871363O-ring

864985Seat

1218659Washer

1161905**Escutcheon

1170944**Connector

1167323**Bonnet

834792Nut

833438Screw

1106842**Plug Button

1160487**Handle

834793Valve

880086O-ring

1120988Anchor1177385**

Mounting Bracket

1119427Screw

1177515Washer1177513**

Bracket Kit

833730Hex Wrench

1248781**Hose

1297484**Handshower

1088901Regulator 77420

Washer

1240266Check Valve

1285735Washer

42084O-ring

1024329O-ring

91640O-ring

32725O-ring

3005148Aerator

3006148Key

1276812Diverter

1285734**Connector

Hose

Bracket

210

60X

60

G1/2˝

82~92G1/2˝

239~249

179

85

Handshower

G1/2˝

G1/2˝

1500

Finished Wall

56 36

5636

36

81

35°35°

150±

15

90º

90º

G1/2˝

250

28 28

240

Page 2: SERVICE PARTS Wall Mount Bath Shower Faucet ...resources.kohler.com/plumbing/kohlerapac/pdf/1176570-2A...shower arm away from heater, or it may become damaged and cause injury to the

1176570-2A-D 2

1176570-2A-D 3

INSTALLATION

How to Install the Faucet

To perform installation, installer must provide G1/2″ female supply fittings (1), spaced 150mm apart and level. The supply fittings should be vertical and not beyond the finished wall. Hot supply pipe must be located on the left.

Install the two offset connectors(2) into the hot and cold supply pipes. Use appropriate thread sealants or thread tape on pipe threads.

Adjust the center-to-center distance between the connectors to 150mm and horizontal. They should extend 36 to 47mm beyond the finished wall.

Slide the escutcheons(3) onto the nuts(4). Put the washers(5) into the nuts, thread the nuts to connectors. Tighten the nuts with strap wrench or soft cloth between product and regular wrench. Push the escutcheon against the finished wall.

Remove the guards on the outlet connectors of the hose(6). Tighten one connector(7) of the hose to the connector(8). Install the regulator(11) into the handshower(10) inlet if needed. Tighten the other connector(9) of the hose to the handshower.

150mm

36~47mm

2

1

Hot

Cold

How to Install the Bracket

Determine a suitable location on the finished wall to install the bracket.

Mark bracket support(12) mounting hole locations on the wall according to the dimension. Drill two holes on the finished wall, the holes should match the anchors(13). Install the anchors. Tighten screws(14) to secure bracket support.

Before installing the bracket(15), check if the ring(16) of the bracket loosen. If yes, tighten the nut(17) on the bottom of the bracket with 9.5mm hex wrench(not provided). Install the washer(18) onto the bottom of the bracket, and then tighten the bracket onto the bracket support until they contact the finished wall.

12

15

13

14

16

17

18

34

5

6

7

8

9

10

11

INSTALLATION CHECKOUT

Ensure that all connections are tightened. Ensure that the handle is in the off position.

Turn on the drain and main water supply, and check for leaks. Repair as needed.

Remove the handshower(10). Remove the aerator(20) with the key(19). Turn on the faucet. Run the water through the spout for about one minute to remove any debris. Check for leaks. Remove any debris from the aerator. Shut off the faucet. Reinstall the handshower and aerator.

CLEANING INSTRUCTIONS

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely affect the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings.

20

10

19

How to Operate the Handshower

Press the buttons of the handshower to change the water flow.

Katalyst Air

Intense Massage

How to Maintain the Handshower

Any debris or mineral build-up may cause the flow stream to become distorted or reduce the flow rate. To remove the debris or mineral build-up, run water through the handshower, firmly press or rub your finger back and forth across the rubber nozzles.

Remove and clean the screen washer.