si cart icd

12
1 Universities Space Research Association SI CART ICD Murali Krishna R. Kandlagunta Mechanical Engineer, USRA Email: [email protected] Phone: 650-604-0946

Upload: abel-duran

Post on 01-Jan-2016

37 views

Category:

Documents


0 download

DESCRIPTION

SI CART ICD. Murali Krishna R. Kandlagunta Mechanical Engineer, USRA Email: [email protected] Phone: 650-604-0946. INTERFACE REQUIREMENTS. PI shall demonstrate the Instrument is capable of handling the maximum loaded configuration of the instrument. This can be done in 2 ways - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: SI CART ICD

1Universities Space Research Association

SI CART ICD

Murali Krishna R. KandlaguntaMechanical Engineer, USRA

Email: [email protected]: 650-604-0946

Page 2: SI CART ICD

2Universities Space Research Association

INTERFACE REQUIREMENTS

• PI shall demonstrate the Instrument is capable of handling the maximum loaded configuration of the instrument. This can be done in 2 ways– AnalysisAnd/or– Proof load test of the cart. Proof load test of GSE Equipment is 125% of

the maximum load configuration• PI shall demonstrate that the loaded SI Cart shall be able to meet the

following physical dimensional requirements in order to safely negotiate through the door and the reinforced path of the aircraft– Height of the loaded SI cart in any configuration shall not exceed 60”– Width of the loaded SI cart shall not exceed 41” – The distance from the edge of the envelope to the rear caster shall not

be more than 69” and the total length shall not exceed 79”– SI cart deck shall be 6” high from the ground – All wheels shall maintain contact with the ramp while negotiating the

ramp– SI Cart shall be able to negotiate the door, door ramp and through the

reinforced aircraft floor without damaging the aircraft and without compromising the safety

Page 3: SI CART ICD

3Universities Space Research Association

Page 4: SI CART ICD

4Universities Space Research Association

Page 5: SI CART ICD

5Universities Space Research Association

Page 6: SI CART ICD

6Universities Space Research Association

• SI Cart Caster requirements– All casters shall be swiveling casters– All casters shall have swivel lock– Casters shall be at least 24” apart. Outside width distance shall not exceed 30”– Load on each caster shall not exceed 600 lbs– Maximum allowable load on the aircraft floor is 500 psi– At least 2 casters shall have braking capability

• Interface requirements of SI cart at the telescope– SI cart shall have the capability to translate in vertical direction between

32.13” to 34.13”– SI cart shall have an angular motion of +/- 0.3 degrees– Minimum spacing from the outer most edge of the SI flange to the outer most

edge of the carts shall be >= 1”• Other Requirements on the SI Cart

– Cart design shall employ dead man brakes– An analysis that shows that designed cart shall not tip over at any load

configurations

Page 7: SI CART ICD

7Universities Space Research Association

Minimum Spacing of 1 inch [25.4 mm]

Page 8: SI CART ICD

8Universities Space Research Association

HIPO CART

Page 9: SI CART ICD

9Universities Space Research Association

FORCAST CART

Page 10: SI CART ICD

10Universities Space Research Association

GREAT CART

Page 11: SI CART ICD

11Universities Space Research Association

Page 12: SI CART ICD

12Universities Space Research Association