siemens access metering product
DESCRIPTION
BMSTRANSCRIPT
Copyright © Siemens AG 2009 - All rights reserved
Siemens Integrated Power Management
Solutions...
...tomorrow’s Technology Today!
Copyright © Siemens AG 2009 - All rights reserved
Top 10 reasons for power monitoring.
Sub Metering and billing
Cost Allocation
Equipment Monitoring
Preventive Maintenance
Demand Analysis Alarm Notification
LEED’s Verification
Accounting
Defer Capital Expenses
Energy Savings / equipment savings verification
Power Quality
Copyright © Siemens AG 2009 - All rights reserved
Key Vertical Market Solutions
Healthcare Hospitals – Emergency Power Supply System (EPSS) Medical Office Buildings (Tenant Metering) Alarm Notifications
Higher Education Cost Allocation Total Utility Monitoring
Critical Power Critical Equipment Monitoring Alarm Notifications
Government Market Energy allocation – who’s using what.
Tenant Metering Billing
Copyright © Siemens AG 2009 - All rights reserved
Additional Market Solutions
Large Malls Mixed Tenant & Retail Resorts Strip Malls LEEDS buildings Court Houses Libraries Motion Picture Studios Airports Universities
Copyright © Siemens AG 2009 - All rights reserved
Why Focus on Energy Monitoring? Global Warming
energy & emissions monitoringReduction of oil & other
natural resources
More efficient power utilization provides savings in all areas of the manufacturing process – material costs, energy costs, taxes, and infrastructure expenses.
Rising power & material costs Global Competition
Copyright © Siemens AG 2009 - All rights reserved
What Does Siemens Have To Offer?
A Totally Integrated Power Management System...
Stand-Alone or SCADA Power Monitoring & Control Software packages tailored to a companies specific requirements.
And, Siemens provides Power Monitoring experts to audit, design and implement a completely Integrated Power Management solution.
Advanced Metering Devices, Relays, Breakers, Drives, LV, MV Flow meters, etc. from Siemens. Also integration to third party devices, other control systems, other data bases and other utilities (gas/water/steam/air).
Copyright © Siemens AG 2009 - All rights reserved
Embedded P-Series / Switchgear / Switchboards, etc., & External Metering
PerformanceReal-time kW, kWh, Amps, Volts, Alarming, PAC(SMU) via serial, Ethernet, or wireless
Energy Logging, Custom Screens, Logic,
Alarming, Built-in Ethernet, optional Profibus DP & Modbus RTU, Expanded 2 Dig In and 2 Dig Outputs, logging,
Modbus Master, Custom Web Pages, Data Concentrator & Central Display (RTU) / 256 samples /cycle
9610
Feat
ures
Advanced Metering Portfolio
PAC-3200
PAC-4200
9360
9340
9510 (RTU)
WFC-Sag/Swell detection, Web Pages,expanded logging, Email Alarming / 128 samples
High Speed Transient Detection, Extensive I/O,Advanced PQ / 1024 samples
50+ Metering measurements, 1 dig In & 1 out, Built-in Ethernet, Profibus DP, Modbus RTU, One & Two piece (Tran) designs
30+ Metering measurements, 2 dig In and 2 Dig Outputs, 1 kWh & kVARh register, Built-in Modbus Serial communications.
PAC-3100
Web Pages, Logic, I/O, Email Alarming
WL COM16
VL COM11
COM16 - Basic WFC, Breaker status, Alarms,Logging, I/O, Modbus RTU, basic metering.
Amperage Metering (Min/Max/Avg) measurements, status readings, Built-in Modbus Serial communications with COM11.
Embedded & External Metering
The entire line of Siemens Energy Medium Voltage products can also be brought in and metered via Modbus.
Copyright © Siemens AG 2009 - All rights reserved
Power Monitoring Solutions!
•PDS has installed solutions around the globe!
• Monitoring everything from incoming medium voltage to floor level single pole breakers.
Key Needs:•Power Utilization Efficiency (PUE)
•Pre-event alarming / post event analysis material
•One system for local and global monitoring
Copyright © Siemens AG 2009 - All rights reserved
Power Monitoring Solutions!
•Monitoring everything from incoming medium voltage to individual tenants.
Key Needs:•Pre-event email alarming / post event analysis material
•One system for local monitoring with ties to BAS (Siemens Apogee) systems
•Tenant Metering
Copyright © Siemens AG 2009 - All rights reserved
Power Monitoring Solutions!
•Monitoring everything from incoming medium voltage to individual buildings.
Key Needs:•Pre-event email alarming
•One system for local monitoring with ties to BAS (Siemens Apogee) systems
•Other utility tie-in’s Gas / Water/ Steam
•Billing Reports
Copyright © Siemens AG 2009 - All rights reserved
Power Monitoring Solutions!
•Monitoring everything from incoming medium voltage, individual buildings and tenant metering.
Key Needs:•Pre-event email alarming
•One system for local monitoring with ties to BAS (Siemens Apogee) systems
•Bringing in other utilities; Gas / Water/ Steam
•Billing Reports
•Generator Testing
Copyright © Siemens AG 2009 - All rights reserved
Power Monitoring Solutions!
•Monitoring everything from incoming medium voltage, individual buildings and tenant metering.
Key Needs:•Meet EPACt regulations
•Pre-event email alarming
•Bringing in other utilities; Gas / Water/ Steam
•Billing Reports
•Global Data transfer of data
Copyright © Siemens AG 2009 - All rights reserved
Power Monitoring Solutions!
•Monitoring all the tenant and common area’s utilities.
Key Needs:•kWh billing data “and”water, gas and steam!
•Hardwire and wireless solutions
•Complete embedded solution – no field installation
•Billing Reports
•Remote Data hosting & collections services
MGM – 4,000 Tenants!!
Copyright © Siemens AG 2009 - All rights reserved
Embedded Metering technology leader in integrated design solutions!
MP636INC - EXTC Self-contained electronics / CT’s &
Communications all in one!! Accurate Revenue Metering Integrated P2-P5 & IPS / SWBD Designs Very Competitive Pricing Modbus Communications Site Commissioning
Copyright © Siemens AG 2009 - All rights reserved
MGM City Center – NV 3850 units, 6 buildings
Belleview Towers
- WA 400 units
Allure Towers – NV 247 units
Vistana San Antonia – TX 267 units
Sky Song, Phoenix, AZ 36 units, Building 1 of 7
Ko Olina Beach Villas HI246 units
The W Hotel & Residence – CA 143 residential and 94 commercial units
Tenant Metering Success Stories
Copyright © Siemens AG 2009 - All rights reserved
Power Monitoring Solutions!
•Siemens provides monitoring and predicting of energy savings and efficiency with a EPMS system.
Key Needs:•kWh metering, trending and logging for conservation of kWh consumption.
•Also documenting gas . Water conservation to achieve high LEED certifications!
Copyright © Siemens AG 2009 - All rights reserved
Energy Dashboard Solutions
Copyright © Siemens AG 2009 - All rights reserved
Power Monitoring Solutions!
WL / VL Breakers with Modbus communication and Power Metering
9510/9610 Power Meter with Ethernet port or 9510RTU Web Based Local Display
PAC Meters with or without display – molded case applications
Copyright © Siemens AG 2009 - All rights reserved
Paralleling Gear – Generators, Cummins, Detroit Diesel, CAT, ASCO..Real-time metering, alarms and status information
Third Party Integration – We Can Do That!!
UPS/PDU/RPP/ STS/ Transfer Switches / Battery Systems
Competitors devices GE, Square D, Eaton and more!
Building Automation Systems – Siemens Apogee, Tran, Johnson Controls and more!
Other Utilities – water, air, gas and Steam.
Real-time metering, alarms and status informationSquare D CM-4000 Meter
Metering, alarms and status information
Real-time metering alarms and status informationfrom Liebert, MGE, Powerware, all the key manufactures.
Copyright © Siemens AG 2009 - All rights reserved
Complete Network Solutions!
The options are endless and used every day in our solutions.
Hardwire (RS-485) Solution
Ethernet (Copper / Fiber ) SolutionsDirect RS-485 shielded twisted pair wire. Runs up to 4000ft. Thirty-two (32) devices per run. Direct Siemens Meter
or External I/O for copper /fiber connectivity.
Siemens Scalance Wireless Ethernet Solutions
Scalance Indoor & Outdoor
Encrypted VLAN over public network, AES Encryption
Copyright © Siemens AG 2009 - All rights reserved
Web Enabled WinPM.Net Software
Fully Integrated Power Monitoring / Power Quality Enterprise Management Software Package containing: Standard tables & screens Graphic configuration tools Reporting in Excel & HTML Logging (SQL) with OPC Alarm Annunciation Basic Manual Control Unlimited Web Based View Only Clients! Support for all the Siemens meters, relays, breakers,
etc. and also an extensive array of third-party devices from Eaton, Square D, GE, Caterpillar, Liebert, MGE, and more.
Designed for the Windows platform. Scalable in design to support all installations including
very large WAN based Ethernet systems.
Copyright © Siemens AG 2009 - All rights reserved
WinPM.Net Standard & Custom Screens
WinPM.Net comes with a multitude of standard or custom screens:
Copyright © Siemens AG 2009 - All rights reserved
Why Siemens? Siemens realizes every facility is unique and with
this in mind we have tailored our offerings to meet every Power Management requirement.
Together we can provide: Reduced Energy Costs – Better Profitability Improved Equipment Efficiency Greater Power Quality diagnostics for faster root cause analysis Achieve tighter government regulations / codes Better Utilization of existing infrastructure – 3rd party & Siemens Reduce costly charges with Demand Management & Load Shedding Cost allocation – track where the energy goes. Extensive modular system support programs, And finally, Empower employees with a new found awareness