sinapi chest drain - wellness pro incorporated · gravity drainage hemothorax pneumothorax no...

2
SINAPI CHEST DRAIN BREAKTHROUGH : 1 WAY VALVE Pneumothorax Hemothorax Gravity Drainage No Clamping Faster Evacuation Promotes Early Patient Mobility Superior Infection Control Advantages For the evacuation of fluids and air from the mediastinal and pleural cavities in post-operative or trauma settings HOW TO USE ( at the back) Exclusively Distributed by: tomorrow’s medical devices WellnessPRO Tel: (02) 636-3580 • Fax: (02) 636-7542 Mobile: (63) 920-947-7185, (63) 922-823-2282 Unit 1006 Richmonde Plaza, San Miguel Avenue corner Lourdes St., Ortigas Center Pasig 1605, Philippines Email: [email protected] [email protected] www.wellnessproinc.com

Upload: lamxuyen

Post on 02-Sep-2018

350 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: SINAPI CHEST DRAIN - Wellness PRO Incorporated · Gravity Drainage Hemothorax Pneumothorax No Clamping ... The SINAPI Chest Drain is a drain chest drainage unit incorporating a dry

SINAPI CHEST DRAINBREAKTHROUGH : 1 WAY VALVE

PneumothoraxHemothoraxGravity Drainage

No ClampingFaster EvacuationPromotes Early Patient MobilitySuperior Infection Control

Advantages

For the evacuation of fluids and air from the mediastinaland pleural cavities in post-operative or trauma settings

HOW TO USE ( at the back)Exclusively Distributed by:

t o m o r r o w ’ s m e d i c a l d e v i c e sWellnessPROTel: (02) 636-3580 • Fax: (02) 636-7542

Mobile: (63) 920-947-7185, (63) 922-823-2282Unit 1006 Richmonde Plaza, San Miguel Avenue cornerLourdes St., Ortigas Center Pasig 1605, Philippines

Email: [email protected]@wellnessproinc.com

www.wellnessproinc.com

Page 2: SINAPI CHEST DRAIN - Wellness PRO Incorporated · Gravity Drainage Hemothorax Pneumothorax No Clamping ... The SINAPI Chest Drain is a drain chest drainage unit incorporating a dry

DESCRIPTION

The SINAPI Chest Drain is a drain chest drainage unit incorporating a dry seal, blood collection reservoir air leak detector, suction bulb and drainage tap.

INDICATIONS

The SINAPI Chest Drain is used for:

post operative and trauma situations.

cavities.3. Facilitation of lung re-expansion and restoration of normal breathing dynamics.

SET UP

HOW TO CONFIRM CHEST CATHETER POSITION DIRECTLY AFTER INSERTION

but initially re-expand.

This will mean that the catheter in not placed in the pleural space (or pneumothorax is resolved).

tubing.

MOBILE PATIENTS

Shorten the chest catheter ( under aseptic technique ) or position on the

loops) . For Pneumothorax, remove the drainage bag. Fig (1)

BED RIDDEN PATIENTS (Gravity Drainage)

Allow gravity drainage by hanging the device next to bed, lower than the chest.

moving/turning the patients you may place the device on its back on the bed – as long as the liquid in the reservoir remains less than the maximum volume indications. Hang next to the bed when unattended. Fig (2)

MANUALLY INCREASING THE DRAINAGE RATE

Increase the drainage rate by depressing the bulb unit until the bulb stays depress Fig (3) If the bulb re-expands, pinch the tubing above the valve and then depress the bulb. Release both. Repeat the process unit until the bulb stays depresses (up to 30x). This applies suction and increase the

-rax will remain and the bulb will not stay depress- attach external suction if required by physician.

ATTACHING LOW PRESSURE SUCTION

If the bulb does not stay depress attach suction as indicated. Keep the drainage tap closed when suction is applied. The recommended suction pressure is -20cmH20 pressure.

DETECTING BUBBLING/AIR LEAK

Depress the bulb. If it stays depress there is no air leak. If it re-expands, add 25ml clean water into the air vent tubing. Look for bubbling or water level movement. Bubbling or water level movement =air leak. Fig (5)

MONITORING

1. Drainage must be low.

must stay depress and the valve angled ( indicating negative intra-pleural/mediastinal pressure)

X-ray.

MAINTENANCE

- Liquid might accumulate in the tube above the valve. This is normal and an indication of negative pressure above the valve.- During outpatient management, secure the chest catheter with additional plaster closer to the reservoir to prevent dislodgment of the catheter.- Replace the device after 7 days.

DRAINAGE INTO BAG

Securely attach the drainage bag into the

into the bag (clamp LP suction tubing to speed up drainage) Close the tap and close the slide clamp of the bag. Remove the

1

2

3

7

10

9

8

4

5

6

Exclusively Distributed by:

t o m o r r o w ’ s m e d i c a l d e v i c e sWellnessPROTel: (02) 636-3580 • Fax: (02) 636-7542

Mobile: (63) 920-947-7185, (63) 922-823-2282Unit 1006 Richmonde Plaza, San Miguel Avenue cornerLourdes St., Ortigas Center Pasig 1605, Philippines

Email: [email protected]@wellnessproinc.com

www.wellnessproinc.com

ARC-Infruitec North CampusLelie roadIdas Valley

Stellenbosch, 7600South Africa