single loop analogue addressable fire control panel

15
Single Loop Analogue addressable fire control Panel

Upload: thomasina-atkins

Post on 11-Jan-2016

231 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Single Loop Analogue addressable fire control Panel

Single Loop Analogue addressable fire control Panel

Page 2: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

• 1 Loop not expandable Panel

• Up to 240 devices on the Loop

• LCD Graphic display

• Navigation keys

• System status leds

• 1 Extinguish channel optional card (certified according EN 12094-1)

• Certified according to EN54-4 ed EN54-2 by IMQ

• Low Cost

Page 3: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

• New generation technology, software selectable protocol

• Up to 240 devices on the Loop

• Self addressing feature

• Up to 2000 m loop length

• Open Line or Loop selectable

• Loop diagnostic feature (detectors contamination level, Loop signal quality, real time value)

• Each device equiped with a short circuit Isolator

Page 4: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

•1,4 A Switching Power supply

• Thermal compensated battery charger

• Battery supervision (efficiency check)

• 30 Zones

Page 5: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

•Self restorable fuses protect outputs and battery

•Battery disconnection in case of deep discharge

•24V Output for external devices feed

•Supervised Dialer Output

• 1 A Supervised Alarm Output

• RS485 BUS for up to 4 repeater connection. On each repeater event view and scroll, reset silence etc.

• RS232 port for UP/Downloading

• 1 Supervised + 1 dry contact fault output

Page 6: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

Using the LCD Graphic display the start up and all the requested programming can be easily done from the front panel

Page 7: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

Using PC Software a clear indication of Loop devices which report the exact connection sequence is available

With a double click device’s parameters can be accessed

Page 8: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

Real Time monitor of each device state is available where a wide range of information are reported

Page 9: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

Up to 8 timers with yearly programming are available

Page 10: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

Logic equation definable by installer to fulfill each installation requirement

Page 11: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

•Optional Card for single channel extinguish system management

SMARTLetLoose/ONE

Page 12: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

•CPD EN12094-1 Approved

Page 13: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

• 1 supervised input for manual release• 1 supervised input for stop release

• 1 supervised input for pressure switch for baloon supervision and release confirm• 1 supervised output for Pre Extinguish signalling

• 1 supervised output for released signalling

Page 14: Single Loop Analogue addressable fire control Panel

Single Loop Fire Control Panel

•SmartLight/G : Up to 240 loop devices, 30 Zones

•SmartLight/S : up to 64 loop devices, 16 zones

•SmartLetLoose/ONE : single channel gas extinguish management card

Page 15: Single Loop Analogue addressable fire control Panel

THANK YOU