DenMasBroto : Technology Make It Possible Category : Antennas VSWR Measurement using Anritsu Site Master 2011-08-02 20:30:24 - by : admin To measure the VSWR there are several ways you can use, one of them by using the VSWR Anritsu Site Master S332B. With this tools we are very watered down to take measurements with accurate results and the results can be printed or in the save in a files. Equipment needed to perform measurements, namely: 1. Anritsu Site Master S332B type 2. Precision OPEN / SHORT, 3. Precision Terminator / LOAD 4. Extension Test Cable. There are 5 (five) items measuring procedures, including: 1. Setting Frequency and Calibration 2. VSWR measurement 3. Measurement of Return Loss (RL) 4. Measurement of Distance to Fault (DTF) 5. Measurement Cable / Waveguide Loss (CL) I. Setting Frequency and Calibration Before conducting measurements, the instruments should be calibrated in advance, while the steps are as follows: A). SETTING RANGE FREQ. 1. Press the MODE 2. Select FREQ-VSWR or Return Loss 3. Press ENTER Page 1 of 5 DenMasBroto : Technology Make It Possible : VSWR Measurement using Anritsu Site ... 1/19/2012 http://denmasbroto.com/cetak-12-vswr-measurement-using-anritsu-site-master.html

Upload: javed-hashim

Post on 26-Oct-2014

37 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Site Master

DenMasBroto : Technology Make It PossibleCategory : Antennas

VSWR Measurement using Anritsu Site Master2011-08-02 20:30:24 - by : admin

To measure the VSWR there are several ways you can use, one of them by using the VSWR Anritsu Site Master S332B.

With this tools we are very watered down to take measurements with accurate results and the results can be printed or in the save in a files.

Equipment needed to perform measurements, namely:1. Anritsu Site Master S332B type2. Precision OPEN / SHORT,3. Precision Terminator / LOAD4. Extension Test Cable.

There are 5 (five) items measuring procedures, including:1. Setting Frequency and Calibration2. VSWR measurement3. Measurement of Return Loss (RL)4. Measurement of Distance to Fault (DTF)5. Measurement Cable / Waveguide Loss (CL)

I. Setting Frequency and CalibrationBefore conducting measurements, the instruments should be calibrated in advance, while the steps are as follows:

A). SETTING RANGE FREQ.1. Press the MODE2. Select FREQ-VSWR or Return Loss3. Press ENTER

Page 1 of 5DenMasBroto : Technology Make It Possible : VSWR Measurement using Anritsu Site ...

1/19/2012http://denmasbroto.com/cetak-12-vswr-measurement-using-anritsu-site-master.html

Page 2: Site Master

4. Press the FREQ / DIST5. Press the F1 soft key6. Enter the numbers 8,9,0 or select a predetermined Freq / stored7. Press ENTER to determine F1 = 890 MHz8. Press the F2 soft key9. Enter the numbers 9,6,0 or select a predetermined Freq / stored10. Press ENTER to determine F2 = 960 MHz

B). CALIBRATION

1. Press the START CAL the message "Connect Open to the RF out port"2. Pairs of precision " OPEN " and then press ENTER, the message "Measuring

OPEN " after the process is complete the message "Connect SHORT to RF out port"3. Remove the precision OPEN , SHORT precision pairs and then press the ENTER

key and the message will appear "Measuring SHORT " after that message appears again 'Connect termination to the RF out "

4. Remove the plug precision and precision termination SHORT press ENTER and the message "Measuring termination"

5. Check at the top left corner posts CAL ON (measuring instruments are properly calibrated).

C). Amplitude / LIMIT

1. Press the amplitude or LIMIT to go to the scales.2. Eg for press softkey TOP VSWR , specify the value of it (eg: 1.3) and press the

BOTTOM for determining the underlying value (eg: 1).3. Eg for press softkey TOP RETURN LOSS , determine its value (eg: 0) and press

the BOTTOM to determine its value (eg: 54)

D). SAVE SETUPTo save the configuration settings press SETUP SAVE then use the arrows to select locations 1-10 and ENTER.

E). RECALL SETUP

1. Press the RECALL SETUP.2. Use the arrows to select the desired setting that ekan then ENTER.

F). SAVE DISPLAY

Page 2 of 5DenMasBroto : Technology Make It Possible : VSWR Measurement using Anritsu Site ...

1/19/2012http://denmasbroto.com/cetak-12-vswr-measurement-using-anritsu-site-master.html

Page 3: Site Master

1. Press SAVE DISPLAY to activate the alphanumeric menu2. Use the softkey to enter the letters / numbers that will be stored in memory.

G). RECALL DISPLAY

1. Press the RECALL DISPLAY2. Use the arrows to select the data that will be displayed and then ENTER.

II. VSWR measurement

1. Press the MODE button.2. Use the arrows to select the FREQ- SWR and then press ENTER.3. To select a frequency range such as PROCEDURE A .4. Then the calibration like procedure B.5. After that plug feeder (end loaded antennas) to gauge or can also use the extension

cable from the measuring instrument, this is to facilitate the mobilization of measurement.

6. Then observe the results of measurements and mark with marker amplitude graph

MARKER SETTING

Page 3 of 5DenMasBroto : Technology Make It Possible : VSWR Measurement using Anritsu Site ...

1/19/2012http://denmasbroto.com/cetak-12-vswr-measurement-using-anritsu-site-master.html

Page 4: Site Master

1. Press the MARKER button to go to the marker.2. M1 softkey, press the EDIT softkey and enter a value3. who desired frequency (eg: 900) press ENTER, the setting M1 = 900 MHz. Press

BACK softkey to return to the marker.4. Repeat Step 1 and 2 for M2.

III. Return Loss Measurement

1. Press the MODE button.2. Use the arrows to select the FREQ- RETURN LOSS and then press ENTER3. The next steps together with VSWR measurements.

V. Measurement of Distance to Fault

1. Press the MODE2. Use the arrows to select the DTF- SWR ENTER3. Calibration and range setting freq. like steps A & B.

IV. Measurement Cable / Waveguide LossCable Loss Measurement using Precision SHORT at the end of feeder

Page 4 of 5DenMasBroto : Technology Make It Possible : VSWR Measurement using Anritsu Site ...

1/19/2012http://denmasbroto.com/cetak-12-vswr-measurement-using-anritsu-site-master.html

Page 5: Site Master

1. Press the MODE2. Use the arrow and select the ONE - PORT CABLE LOSS , press ENTER3. Press to enter the menu amplitude scale4. Press softkey and define the values it TOP5. BOTTOM softkey and define the bottom.

THINGS TO NOTE:

l Calibration of measuring instruments must always be done before starting the measurements.

l Knowing the specifications of the material such Loss Connector, Feeder, feeder jumpers, splitters, antenna and others.

l Before measuring, make sure first that the installation is mounted fine.l Using the extension cable to move more freely in doing measurement

DenMasBroto : Technology Make It Possible : http://www.denmasbroto.comOnline Version : http://www.denmasbroto.com/article/12/vswr-measurement-using-anritsu-site-master.html