    QUOTE FORM

    Scope of Work1832 Mazzanti Way, Henderson, NV 89014

    THE SOUTl-lERN NEVADA REGIONAL HOUS1NGAUTHORI1Y 340 N. 11.M

    STREET. lASVEGAS, NV 89101~3611

    This Requestfor Quole numberis Q10106 for the following:

    Rehabilitationand EnergyUpgrades@ 1632MazzantiWay, Henderson.NVNeighborhoodStabilizationProgram(NSP)

    Work listed below shall meet the following standards:1. Home Perfomnance Standards for Warm Climates (HPSFWC)2. Clark County Optional Specifications for Water Saving Measures, October 2009 (WSM)

    3. Clark County Housing Rehabilitation Specification Manual

    4. Southern Nevada Regional Housing Authority specifications ~ 1 15. Standard Materials/Appliance List included in this Work Scope6. Other requirements specifically listed in this Work Scope (incl. Installation Notes) ~

    7. Local building codes and amendments for new or substantially altered work ';J/7 \ '/: ("" " 3 . / - S8. Saturn Mechanical Systems Field Guide, Chapter 6 (2006) " . . " ' V ' - . ~ \:f9. NSP Rental Project Standards Draft 5/25/2010 ~ I'U'"10. Guidelines for Complying with BPI's Technical Standards for the Air Conditionin and Heat Pump vJ 0

    Professional . .' . t1 011. When the above documents contain multiple or confhcllng requirements, the most tnngent shall ap$\Y

    SCOPE OF WORK

    Health Safe & Bulldln Code Measures

    Hard wire smoke detectors with battery backup in 3 Quantity = 3

    bedrooms and near kitchen and test

    $

    Install CO detector(s) per manufacture(s specifications.

    Detectors to be linked to each other, hard wired with battery

    backup.

    Provide mechanical ventilation per AHSRAE 62.2-2003based on all installed building shell sealing and energy

    efficiency measures ) \ c 1 ' 0 \t J t f J

    Insulate exposed hot and cold water pipes with foam pipeinsulation (R-4 min). Ensure 3" space between single wall

    vent pipe. Use correct diameter of insulation sleeve so it fits

    tightly. Seal at wall penetrations.

    Install arc fault breakers for bedrooms (3)

    Laundry: Replace existing assembly with metal washing

    machine shut off valve with hammer arrestor.

    Add two seismic straps to DHW Heater, secured to studs.

    Add approved cover, gasket and seal outside electrical

    outlets and switches. Re uires GFCI

    Ensure electrical on outside of home to addition conforms

    with current codeRemove and replace non code shower entry at hall bath

    Combustion Appliance Zone test out and repair (to be done

    by contractor or subcontractor)

    Quantity = 1

    Install Panasonic FV-04VE1 WhisperComfort Spot ERV Ceiling Insert

    Ventilator with Balance Ventilation and

    Patent-Pending Capillary Core (set for

    44 cfm continuous

    Preformed foam (e.g. closed cell

    polyethylene) conforming to ASTM

    C534. Tape seams, joints and ends of

    pipe sleeves. Use gun foam/caulk.

    e.g. Watts Water Technologies 2T-M2

    Straps - Upper 1/3 and Lower 1/3 or 4"above controls

    (Approx 3) e.g. Taymac MM410W (2-

    3/4" Dee

    Estimate based on improvements

    needed

    Required when air sealing or ductsealing.

    1 6 5 '0

    Electrical Panel

    Legibly label all breakers in panel to clearly indicate areaserved

  • 8/9/2019 SNRHA - 1832 Mazzanti Way 89014

    2/3

    THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N, 11' '' STREET. LAs VEGAS, NV 89101.3611

    This Requestfor Quotenumber,s 010106 for the following:

    Rehabilitationand Energy Upgrades@ 1832MazzantiWay. Henderson.NV

    NeighborhoodStabilizationProgram(NSP)

    QUOTE FORMPage 2 of6

    Energy Efficiency MeasuresJ fit t"n I ra Ion ,.Reduce air leakage of the building shell to 1049 CFM50 See Insulation. yffl.JSeal all outdoor light fIXtures to wall. Leave bottom of fixture

    ~CL.unsealed

    Weatherstrip doors /50Windows Approx. 211 sq. ft.

    Remove existing film and Install Solar Film (CP Film N1040SR CDF\ 'or comnarable

    HVAC & Insulation

    Replace eXIsting HVAC System based on provided Amana AMV9 series 95 AFUE 2-stage

    82>50supporting load calc's & install programmable, variable speed closed combustion gascommunicating thermostat furnace. Amana ASX series 16 SEERsystem, with Amana communicating

    thermostat and matching evaporator

    coil. Systems shall have minimum 5vears narts warranty

    Lower ductwork, bury in blown cellulose after sealing ducts (1) System

    ...1!J O Oto < 6% ILeakaae to OutsidelRight Size Air Conditioning/Heating System: Manual J, D S

    S l!.- f . . 5t!.& ,: p r z -o F r .rII.; .

    Change supply grills with operable curve blades to improve : : r r J C L . .throw. Seal all boot to drvwall connections.

    Seal all attic ventilation. 'IW~

    Remove existing batt and blown insulation and air seal

    penetrations. Re-install fiberglass batts around FAU without

    voids or gaps (compression is permitted). Add blown

    cellulose to remainder of attic to increase to R-50

    Knee Walls: Remove existing batt insulation and air seal

    penetrations. Re-install fiberglass batts to R-19 withoutvoids or gaps and strap in place and install FSK material as

    six sided assembly.

    Install transfer grilles above each bedroom door(3) mimmum of 16" x 8" IrlC .L .

    Lighting

    Replace all incandescent light bulbs with compact General. Eco-Smart 14w Soft White orfluorescent bulbs (CFL) Use appropriate style for fixture. If equivalent Lamps to have min. 7 yearfixture will not support a CFL, replace fixture with warranty. Provide appropriate lampcomparable CFL fixture format for fixture.

    Replace all existing light fIxtures with Energy Star rated (3) Bedrooms - Portfolio 2-Light Rusticfixtures. Brown Ceiling Flush mount, model

    nO.LC0463RB

    Install Energy Star rated bath light f,xtures in all baths Approx 3

    Replace T-12 lamps and ballasts in kitchen with T-8

    Replace entryway and rear patio light f,xtures with Energy

    Star rated f,xlures~~.---~-------.. - -----"--- ..- ---

  • 8/9/2019 SNRHA - 1832 Mazzanti Way 89014

    3/3

    TH E SOUTHERN NEVADA REGIONA.L HOUSING AUTHORITY 340 N 1 1'~ STREET. LAS VEGAS, NV 89101.3611

    This Request for Quote number is 010106 for the following

    Rehabilitation and Energy Upgrades@ 1832 Mazzanti Way, Henderson, NV

    Neighborhood Stabilization Program (NSP)

    QUOrE FORMPage 4 of 6

    Install new Range GE 30 In. Freestanding Gas Range

    Mooel # JGBS07DEMee

    Install over the oven microwave GE Spacemaker@ Over-the-Range

    Microwave Oven, Model #:

    JVM1540DNWW

    (exhaust vented to outside min. 120

    cfm)

    ExteriorPatch and touch up paint exterior walls and trim Low voe paints

    Garage

    Finish drywall and paint Garage walls and ceiling. Low voe paints.

    Landscaping

    Remove all dead plants and trim all plantings as needed. Bring grade up in rear to cover footing

    General weed and clean of yard and. Front and rear.

    Add 0 /." rock to match existing to back yard.

    Other

    Install electrical plates as needed throughout

    Install door hardware as needed. To match eXlstinQ.

    Replace attic access hatch with new piece of drywall.

    Texture to match eXlstlnQ and paint

    Remove any mold/mildew and caulk all showers, baths,

    countertops and vinyl areas (2) Bathrooms and kitchen.

    Total Non-Enerav Efficlencv MeasuresSNRHA Typical Work Items for NSP Properties (any items not

    included above)

    TesllnglMisc.

    Perform blower door test per attached Testing Schedule and

    provide written report

    Perform duct leakage for all HVAC systems test after work is

    completed and duct sealing specifications have been met and

    provide written reportTest and calibrate all systems for proper operation per codes,

    manufacturer's specifications and HPSWFC Ch. 5, provide written

    report of items tested and results. Adjust equipment to comply withoperational standards.

    Test combustion eqUIpment and adjust/repair as needed (per BPI

    Performance Specificallons and HPSFWC Ch. 6), provide written

    report of items tested and results

    Subcontracted Professionals:

    Structural Engineer (as applicablelif not included in above work)

    Mechanical Engineer (as applicable/if not included in abovework)

    Certified Energy Consultant (as applicable/if not included in

    above work)

    Total Testing/Subcontracted Professional

    /6,

    $

    $

    $ /050

    $ A & o V f

    $