solenoid valves, mechanical and manual valves · vxz22 & -23 – zero differential pressure...

56
47 4 Solenoid valves, mechanical and manual valves Valve control, general symbol Valve control, roll Valve control, spring Valve control, push button Valve control, pilot valve Valve control, direct acting solenoid Valve control, solenoid pilot valve 3/2 valve, normally closed, monostable, pressure-controlled with spring return 2/2 valve, normally closed, monostable, push button-controlled with spring return 3/2 valve, normally closed 3/2 valve, normally open 5/2 valve, bistable 5/2 valve, monostable 5/3 valve, closed center 5/3 valve, open center 5/3 valve, pressurized center Double 3/2 valve, normally closed/normally closed Double 3/2 valve, normally closed/normally open Double 3/2 valve, normally open/normally open 1 3 2 12 1 2 1 3 2 1 3 2 13 5 2 4 13 5 2 4 5 13 4 2 5 13 4 2 5 13 4 2 1 3 2 5 4 1 3 2 5 4 1 3 2 5 4

Upload: others

Post on 16-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

47

4

Solenoid valves, mechanical

and manual valves

Valve control, general symbol

Valve control, roll

Valve control, spring

Valve control, push button

Valve control, pilot valve

Valve control, direct acting solenoid

Valve control, solenoid pilot valve

3/2 valve, normally closed, mono stable, pressure-controlled

with spring return

2/2 valve, normally closed, mono stable, push button-controlled

with spring return

3/2 valve, normally closed

3/2 valve, normally open

5/2 valve, bi stable

5/2 valve, mono stable

5/3 valve, closed center

5/3 valve, open center

5/3 valve, pressurized center

Double 3/2 valve, normally closed/normally closed

Double 3/2 valve, normally closed/normally open

Double 3/2 valve, normally open/normally open

13

2

12

1

2

13

2

13

2

1 35

24

1 35

24

5 1 3

4 2

5 1 3

4 2

5 1 3

4 2

1 3

2

5

4

1 3

2

5

4

1 3

2

5

4

Page 2: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

48

57

Cv 0.44 58

Cv 0.88 61

Cv 0.05 64

Cv 0.12 65

Cv 0.21 66

Cv 0.74 68

Cv 0.29 70

Cv 0.9 72

Cv 1.4 74

Cv 2.5 76

Cv 0.98–2.45 79

Cv 0.19 80

Cv 0.5 81

Cv 1 83

Cv 0.08–0.12 84

Cv 0.25 86

Cv 0.8 90

Cv 2 94

Cv 4.7 98

Cv 0.28 98

Cv 0.23 99

Cv 0.48 101

Cv 0.56 102

Cv 0.93 104

Cv 1.6 106

Cv 0.28–0.93 108

Cv 1.4 109

Cv 0.8 110

Cv 1 111

Cv 1.5 113

Cv 3.2 115

Cv 4.9 117

Cv 1.5–4.9 118

Cv 0.006–0.021 119

Cv 0.008–0.016 120

Cv 0.008 121

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

4/2, 5/2 and 5/3 solenoid valvesSY3000 & -5000 – overview

SY3000 – solenoid valve, plug-in

SY5000 – solenoid valve, plug-in

VQD1000 – 4/2 solenoid valve

SYj3000 – solenoid valve

SYj5000 – solenoid valve

SYj7000 – solenoid valve

SY3000 – solenoid valve

SY5000 – solenoid valve

SY7000 – solenoid valve

SY9000 – solenoid valve

VF3000 & -5000 – solenoid valve

SY3060 – valve manifold, cassette type

SY5060 – valve manifold, cassette type

SY7060 – valve manifold, cassette type

Sj2000 & -3000 – solenoid valve manifold, plug-in, cassette type

VQC1000 – solenoid valve, plug-in

VQC2000 – solenoid valve, plug-in

VQC4000 – solenoid valve, plug-in

VQ5000 – solenoid valve, plug-in

ContentsSV1000 – solenoid valve, tie rod type

SV1000 – solenoid valve, cassette type

SV2000 – solenoid valve, tie rod type

SV2000 – solenoid valve, cassette type

SV3000 – solenoid valve, plug-in

SV4000 – solenoid valve, plug-in

SV1000, -2000 & -3000 – solenoid valve, body ported

VFn nAMuR – solenoid valve

VFS2000 – solenoid valve, plug-in

VSR8-4 & VSS8-4 – solenoid valve, plug-in, ISO 15407-2

EVS7-6 & VQ7-6 – solenoid valve, ISO1

EVS7-8 & VQ7-8 – solenoid valve, ISO2

EVS7-10 – solenoid valve, ISO3

EVS7-XSE647 – solenoid valve, ISO

3/2 solenoid valvesS070 – 3/2 miniature solenoid valve

V114 & V111 – solenoid valve

VV100 – 3/2 block mounted solenoid valve, cassette type

Multiply Cv by 980 to get a Qn value in ln/min.

Page 3: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

49

Cv 0.1–0.5 123

Cv 0.2–0.7 125

Cv 0.2 126

Cv 0.9–3.7 127

Cv 7.4–13.1 129

Cv 0.39–0.78 130

Cv 0.05–3.2 131

Cv 0.05–1 133

Cv 7.4–13.1 134

135

136

Cv 0.35–6 137

Cv 0.07–6 137

Cv 0.35–3.3 138

Cv 0.35–8 138

Cv 0.018 139

Cv 0.03–0.04 139

Cv 0.015–0.065 140

Cv 0.03–0.44 141

Cv 0.03–0.44 142

Cv 0.33–2.1 143

Cv 0.23–2.21 144

Cv 0.17–2.2 146

Cv 0.17–2.2 151

Cv 0.61 152

Cv 1.9–13 153

Cv 1.9–12 154

Cv 1.9–12 155

Cv 2.4–12 156

Cv 1–48 157

Cv 1.25–18.3 158

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

SYj300, -500 & -700 – 3/2 solenoid valve

EVT307, VO307 & EVT317 – 3/2 solenoid valve

VKF300 – 3 port direct operated solenoid valve

VP – 3/2 solenoid valve, body ported

VG342 – solenoid valve, body ported, IP65

2/2 solenoid valvesVQ20 & -30 – 2/2 solenoid valve

Mechanical, manual valvesVM, EVM, EVZM, VHK, VH & VR – mechanical, manual valves

air operated valvesSYjA, SYA & EVPA – 3/2, 5/2, 5/3 air operated valve

VGA342 – air operated 3/2 valve, body ported

Proportional flow valvesPVQ10 – proportional flow valve

PVQ30 – proportional flow valve

Media valvesLVC – 2/2 air operated chemical valve

LVA – 2/2 air operated chemical valve

LVH – 2/2 manually operated chemical valve

LVQ – 2/2 air operated corrosion resistant chemical valve

LVM09/090 – 2/3 port direct operated solenoid valve for chemistry & analysis

LVM10/100 – 2/3 port direct operated solenoid valve for chemistry & analysis

LVM15/150 & -20/200 – 2/3 port direct operated solenoid valve for chemistry & analysis

VDW10, -20 & -30 – 2/2 solenoid valve for water & air

VDW200 & -300 – 3/2 solenoid valve for water & air

VCA – solenoid valve for air & inert gases

new VX21, -22 & -23 – normally closed, 2 port direct operated solenoid valve

VX21, -22 & -23 – 2 port direct operated solenoid valve

VXK21, -22 & -23 – 2 port direct operated solenoid valve with built-in strainer

VXK with electronic timer and built-in strainer

VXD21 & -22 – pilot operated solenoid valve for water & other neutral media

VXZ22 & -23 – zero differential pressure solenoid valve with brass body

VXZ22 & -23 – zero differential pressure solenoid valve with stainless steel body

VXS22 & -23 – zero differential pressure solenoid valve for steam

VnB & VnD – 2/2 air operated valve for neutral media or steam

SGC – 2/2 air operated valve for cutting fluids

Page 4: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

50

Sy3000 Sy7000Sy5000Sy3000 PluG-In

SJ2000/3000

VQD1000

VK3000

SyJ7000 SyJ5000 SyJ3000

SX5000 SX3000 SX7000

VQZ2000VQZ1000 VQZ3000

SV4000SV2000 SV1000 SV3000

VQ5000 VQC4000 VQC2000 VQC1000

VF5000 VF3000 VF1000

VQ7-8 VQ7-6

VFr6000 VFr5000VFr3000 VFr2000 VFr4000

VP4070 VP4050

VZS3000 VZS2000

VQZ2000 VQZ1000 VQZ3000

VS410

VQ5000 VQC4000 VQC2000 VQC1000

VQ7-8 VQ7-6

VFS6000 VFS5000VFS4000 VFS1000 VFS3000VFS2000

Ø6 Ø10 Ø16 Ø20 Ø25 Ø32 Ø40 Ø50 Ø63 Ø80 Ø100 Ø125 Ø140 Ø160 Ø180 Ø200 Ø250 Ø300

VQD1 0.07 2 M5 4

VK1 0.12 4 M5, 1/8 4, 6

SJ 0.08–0.12 0.6 M3, M5 2, 4, 6

SyJ 0.12–0.74 0.35 (0.1)2 M3, M5, 1/8, 1/4 4, 6, 8

SX 0.18–0.82 0.6 M5, 1/8, 1/4, 3/8 4, 6, 8, 10

VQZ 0.32–1.2 0.4 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

SV 0.28–1.6 0.6 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VQ/VQC 0.2–4.7 0.4 M5 3.2, 4, 6, 8, 10, 12

Sy 0.26–2.5 0.35 (0.1)2 M5, 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VF 0.13–3 1.8 M5, 1/8, 1/4, 3/8, 1/2 —

VQ7 1.4–3.3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10

VFr 0.7–10.6 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

VP4 5.6–16.7 12 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2 —

VZS 0.33–0.53 1.8 1/8, 1/4 4, 6, 8

VQZ 0.17–0.74 1 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

VS4 1 5.5 1/8, 1/4, 3/8 —

VQ/VQC 0.18–3.4 1 M5, 1/4, 3/8 3.2, 4, 6, 8, 10, 12

VQ7 1.1–3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10, 12

VFS 0.4–9 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

Sy9000 (see example 1)

Seal typerubber seal: Resistant to dust when the seals between the spool and sleeve are made of rubber.

Metal seal: Long life thanks to the air bearing be-tween metal spool and steel sleeve.

Directional control valves – solenoid valves

Conditions■ Pressure: 0.5 MPa■ Tubing length: 1 m■ Load: 50%■ Stroke: 200 mm■ Speed: 100 mm/s or lower

Cylinder size and speedExample 1: When using the valve series SY9000 (2500 ln/min) for driving Ø40 to Ø100 cylinders, they will have an average speed under the following conditions.

Ideal size for actuator control

Sea

l typ

e,

mai

n v

alve

Valve series

Flow characteristics

A, BE(2 position/ mono stable)

Applicable cylinder Speed: 100 mm/s or lower

Power consumption (W)

Connection size

Threaded connection (G)

Push-in fitting (Ø)applicable tubing size (mm) Cv value3

Rub

ber

sea

lM

etal

sea

l

1. Only available with single coil. 2. number in parentheses stands for power saving circuit. 3. Multiply by 980 to get a Qn value in ln/min.

Page 5: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

51

1 2

VFr6000

VP4070

VFS6000

Ø6 Ø10 Ø16 Ø20 Ø25 Ø32 Ø40 Ø50 Ø63 Ø80 Ø100 Ø125 Ø140 Ø160 Ø180 Ø200 Ø250 Ø300

VQD1 0.07 2 M5 4

VK1 0.12 4 M5, 1/8 4, 6

SJ 0.08–0.12 0.6 M3, M5 2, 4, 6

SyJ 0.12–0.74 0.35 (0.1)2 M3, M5, 1/8, 1/4 4, 6, 8

SX 0.18–0.82 0.6 M5, 1/8, 1/4, 3/8 4, 6, 8, 10

VQZ 0.32–1.2 0.4 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

SV 0.28–1.6 0.6 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VQ/VQC 0.2–4.7 0.4 M5 3.2, 4, 6, 8, 10, 12

Sy 0.26–2.5 0.35 (0.1)2 M5, 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VF 0.13–3 1.8 M5, 1/8, 1/4, 3/8, 1/2 —

VQ7 1.4–3.3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10

VFr 0.7–10.6 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

VP4 5.6–16.7 12 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2 —

VZS 0.33–0.53 1.8 1/8, 1/4 4, 6, 8

VQZ 0.17–0.74 1 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

VS4 1 5.5 1/8, 1/4, 3/8 —

VQ/VQC 0.18–3.4 1 M5, 1/4, 3/8 3.2, 4, 6, 8, 10, 12

VQ7 1.1–3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10, 12

VFS 0.4–9 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

5 port for pneumatics

Power consumptionreduction of necessary power for the valveWith power saving circuit: The power consumption is reduced to one quarter of the standard product power consumption. (The effect occurs when the on time is greater than 62 ms and operated at rated voltage of 24 VDC.)

Electrical circuit (with energy saving circuit)

1: Actuation power 2: Holding current

Red (+)

Coil

Tim

e ci

rcui

t LED

Dio

de

Black (–)

Ideal size for actuator control

Sea

l typ

e,

mai

n v

alve

Valve series

Flow characteristics

A, BE(2 position/ mono stable)

Applicable cylinder

Power consumption (W)

Connection size

Threaded connection (G)

Push-in fitting (Ø)applicable tubing size (mm) Cv value3

Rub

ber

sea

lM

etal

sea

l

1. Only available with single coil. 2. number in parentheses stands for power saving circuit. 3. Multiply by 980 to get a Qn value in ln/min.

Page 6: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

52

Sy3000 Sy7000Sy5000Sy3000 PluG-In

SJ1000/2000

VQD1000

VK3000

SyJ7000 SyJ5000 SyJ3000

SX5000 SX3000 SX7000

VQZ2000VQZ1000 VQZ3000

SV4000SV2000 SV1000 SV3000

VQ5000 VQC4000 VQC2000 VQC1000

VF5000 VF3000 VF1000

VQ7-8 VQ7-6

VFr6000 VFr5000VFr3000 VFr2000 VFr4000

VP4070 VP4050

VZS3000 VZS2000

VQZ2000 VQZ1000 VQZ3000

VS410

VQ5000 VQC4000 VQC2000 VQC1000

VQ7-8 VQ7-6

VFS6000 VFS5000VFS4000 VFS1000 VFS3000VFS2000

Ø6 Ø10 Ø16 Ø20 Ø25 Ø32 Ø40 Ø50 Ø63 Ø80 Ø100 Ø125 Ø140 Ø160 Ø180 Ø200 Ø250 Ø300

VQD1 0.07 2 M5 4

VK1 0.12 4 M5, 1/8 4, 6

SJ 0.08–0.12 0.6 M3, M5 2, 4, 6

SyJ 0.12–0.74 0.35 (0.1)2 M3, M5, 1/8, 1/4 4, 6, 8

SX 0.18–0.82 0.6 M5, 1/8, 1/4, 3/8 4, 6, 8, 10

VQZ 0.32–1.2 0.4 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

SV 0.28–1.6 0.6 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VQ/VQC 0.2–4.7 0.4 M5 3.2, 4, 6, 8, 10, 12

Sy 0.26–2.5 0.35 (0.1)2 M5, 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VF 0.13–3 1.8 M5, 1/8, 1/4, 3/8, 1/2 —

VQ7 1.4–3.3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10

VFr 0.7–10.6 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

VP4 5.6–16.7 12 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2 —

VZS 0.33–0.53 1.8 1/8, 1/4 4, 6, 8

VQZ 0.17–0.74 1 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

VS4 1 5.5 1/8, 1/4, 3/8 —

VQ/VQC 0.18–3.4 1 M5, 1/4, 3/8 3.2, 4, 6, 8, 10, 12

VQ7 1.1–3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10, 12

VFS 0.4–9 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

Sy9000 (see example 1)

Ideal size for actuator control

Sea

l typ

e,

mai

n v

alve

Valve series

Flow characteristics

A, BE(2 position/ mono stable)

Applicable cylinder Speed: 300 mm/s or lower

Power consumption (W)

Connection size

Threaded connection (G)

Push-in fitting (Ø)applicable tubing size (mm) Cv value3

Rub

ber

sea

lM

etal

sea

l

1. Only available with single coil. 2. number in parentheses stands for power saving circuit. 3. Multiply by 980 to get a Qn value in ln/min.

Directional control valves – solenoid valves

Seal typerubber seal: Resistant to dust when the seals between the spool and sleeve are made of rubber.

Metal seal: Long life thanks to the air bearing be-tween metal spool and steel sleeve.

Conditions■ Pressure: 0.5 MPa■ Tubing length: 1 m■ Load: 50%■ Stroke: 200 mm■ Speed: 300 mm/s or lower

Cylinder size and speedExample 1: When using the valve series SY9000 (2500 ln/min) for driving Ø40 to Ø100 cylinders, they will have an average speed under the following conditions.

Page 7: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

53

1 2

VP4070

Ø6 Ø10 Ø16 Ø20 Ø25 Ø32 Ø40 Ø50 Ø63 Ø80 Ø100 Ø125 Ø140 Ø160 Ø180 Ø200 Ø250 Ø300

VQD1 0.07 2 M5 4

VK1 0.12 4 M5, 1/8 4, 6

SJ 0.08–0.12 0.6 M3, M5 2, 4, 6

SyJ 0.12–0.74 0.35 (0.1)2 M3, M5, 1/8, 1/4 4, 6, 8

SX 0.18–0.82 0.6 M5, 1/8, 1/4, 3/8 4, 6, 8, 10

VQZ 0.32–1.2 0.4 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

SV 0.28–1.6 0.6 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VQ/VQC 0.2–4.7 0.4 M5 3.2, 4, 6, 8, 10, 12

Sy 0.26–2.5 0.35 (0.1)2 M5, 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VF 0.13–3 1.8 M5, 1/8, 1/4, 3/8, 1/2 —

VQ7 1.4–3.3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10

VFr 0.7–10.6 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

VP4 5.6–16.7 12 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2 —

VZS 0.33–0.53 1.8 1/8, 1/4 4, 6, 8

VQZ 0.17–0.74 1 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

VS4 1 5.5 1/8, 1/4, 3/8 —

VQ/VQC 0.18–3.4 1 M5, 1/4, 3/8 3.2, 4, 6, 8, 10, 12

VQ7 1.1–3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10, 12

VFS 0.4–9 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

5 port for pneumaticsIdeal size for actuator control

Sea

l typ

e,

mai

n v

alve

Valve series

Flow characteristics

A, BE(2 position/ mono stable)

Applicable cylinder

Power consumption (W)

Connection size

Threaded connection (G)

Push-in fitting (Ø)applicable tubing size (mm) Cv value3

Rub

ber

sea

lM

etal

sea

l

1. Only available with single coil. 2. number in parentheses stands for power saving circuit. 3. Multiply by 980 to get a Qn value in ln/min.

Power consumptionreduction of necessary power for the valveWith power saving circuit: The power consumption is reduced to one quarter of the standard product power consumption. (The effect occurs when the on time is greater than 62 ms and operated at rated voltage of 24 VDC.)

Electrical circuit (with energy saving circuit)

1: Actuation power 2: Holding current

Red (+)

Coil

Tim

e ci

rcui

t LED

Dio

de

Black (–)

Page 8: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

54

Sy3000 Sy7000Sy5000Sy3000 PluG-In

SJ1000/2000

SX5000 SX3000 SX7000

VQZ2000VQZ1000 VQZ3000

SV4000SV2000 SV1000 SV3000

VQ7-8 VQ7-6

VFr6000 VFr5000VFr3000 VFr2000 VFr4000

VP4070 VP4050

VZS3000 VZS2000

VQZ2000 VQZ1000 VQZ3000

VS410

VQ7-8 VQ7-6

VFS6000 VFS5000VFS4000 VFS1000 VFS3000VFS2000

VQD1000

VK3000

SyJ7000 SyJ5000 SyJ3000

VF5000 VF3000 VF1000

VQ5000 VQC4000 VQC2000 VQC1000

VQ5000 VQC4000 VQC2000 VQC1000

Ø6 Ø10 Ø16 Ø20 Ø25 Ø32 Ø40 Ø50 Ø63 Ø80 Ø100 Ø125 Ø140 Ø160 Ø180 Ø200 Ø250 Ø300

VQD1 0.07 2 M5 4

VK1 0.12 4 M5, 1/8 4, 6

SJ 0.08–0.12 0.6 M3, M5 2, 4, 6

SyJ 0.12–0.74 0.35 (0.1)2 M3, M5, 1/8, 1/4 4, 6, 8

SX 0.18–0.82 0.6 M5, 1/8, 1/4, 3/8 4, 6, 8, 10

VQZ 0.32–1.2 0.4 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

SV 0.28–1.6 0.6 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VQ/VQC 0.2–4.7 0.4 M5 3.2, 4, 6, 8, 10, 12

Sy 0.26–2.5 0.35 (0.1)2 M5, 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VF 0.13–3 1.8 M5, 1/8, 1/4, 3/8, 1/2 —

VQ7 1.4–3.3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10

VFr 0.7–10.6 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

VP4 5.6–16.7 12 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2 —

VZS 0.33–0.53 1.8 1/8, 1/4 4, 6, 8

VQZ 0.17–0.74 1 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

VS4 1 5.5 1/8, 1/4, 3/8 —

VQ/VQC 0.18–3.4 1 M5, 1/4, 3/8 3.2, 4, 6, 8, 10, 12

VQ7 1.1–3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10, 12

VFS 0.4–9 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

Sy9000 (see example 1)

Ideal size for actuator control

Sea

l typ

e,

mai

n v

alve

Valve series

Flow characteristics

A, BE(2 position/ mono stable)

Applicable cylinder Speed: 500 mm/s or lower

Power consumption (W)

Connection size

Threaded connection (G)

Push-in fitting (Ø)applicable tubing size (mm) Cv value3

Rub

ber

sea

lM

etal

sea

l

1. Only available with single coil. 2. number in parentheses stands for power saving circuit. 3. Multiply by 980 to get a Qn value in ln/min.

Directional control valves – solenoid valves

Seal typerubber seal: Resistant to dust when the seals between the spool and sleeve are made of rubber.

Metal seal: Long life thanks to the air bearing be-tween metal spool and steel sleeve.

Conditions■ Pressure: 0.5 MPa■ Tubing length: 1 m■ Load: 50%■ Stroke: 200 mm■ Speed: 500 mm/s or lower

Cylinder size and speedExample 1: When using the valve series SY9000 (2500 ln/min) for driving Ø40 to Ø100 cylinders, they will have an average speed under the following conditions.

Page 9: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

55

1 2

Ø6 Ø10 Ø16 Ø20 Ø25 Ø32 Ø40 Ø50 Ø63 Ø80 Ø100 Ø125 Ø140 Ø160 Ø180 Ø200 Ø250 Ø300

VQD1 0.07 2 M5 4

VK1 0.12 4 M5, 1/8 4, 6

SJ 0.08–0.12 0.6 M3, M5 2, 4, 6

SyJ 0.12–0.74 0.35 (0.1)2 M3, M5, 1/8, 1/4 4, 6, 8

SX 0.18–0.82 0.6 M5, 1/8, 1/4, 3/8 4, 6, 8, 10

VQZ 0.32–1.2 0.4 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

SV 0.28–1.6 0.6 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VQ/VQC 0.2–4.7 0.4 M5 3.2, 4, 6, 8, 10, 12

Sy 0.26–2.5 0.35 (0.1)2 M5, 1/8, 1/4, 3/8, 1/2 4, 6, 8, 10, 12

VF 0.13–3 1.8 M5, 1/8, 1/4, 3/8, 1/2 —

VQ7 1.4–3.3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10

VFr 0.7–10.6 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

VP4 5.6–16.7 12 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2 —

VZS 0.33–0.53 1.8 1/8, 1/4 4, 6, 8

VQZ 0.17–0.74 1 M5, 1/8, 1/4, 3/8 3.2, 4, 6, 8, 10

VS4 1 5.5 1/8, 1/4, 3/8 —

VQ/VQC 0.18–3.4 1 M5, 1/4, 3/8 3.2, 4, 6, 8, 10, 12

VQ7 1.1–3 1 1/4, 3/8, 1/2, 3/4 6, 8, 10, 12

VFS 0.4–9 1.8 1/8, 1/4, 3/8, 1/2, 3/4, 1 —

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

5 port for pneumaticsIdeal size for actuator control

Sea

l typ

e,

mai

n v

alve

Valve series

Flow characteristics

A, BE(2 position/ mono stable)

Applicable cylinder

Power consumption (W)

Connection size

Threaded connection (G)

Push-in fitting (Ø)applicable tubing size (mm) Cv value3

Rub

ber

sea

lM

etal

sea

l

1. Only available with single coil. 2. number in parentheses stands for power saving circuit. 3. Multiply by 980 to get a Qn value in ln/min.

Power consumptionreduction of necessary power for the valveWith power saving circuit: The power consumption is reduced to one quarter of the standard product power consumption. (The effect occurs when the on time is greater than 62 ms and operated at rated voltage of 24 VDC.)

Electrical circuit (with energy saving circuit)

1: Actuation power 2: Holding current

Red (+)

Coil

Tim

e ci

rcui

t LED

Dio

de

Black (–)

Page 10: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

56

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

a valve spool change position inside the valve when it is affected manually, with spring force, or when power is applied to the coil. The spool position de-

termines which ports are pressurised and exhausted.Many valves have a so called rubber seal, which can

be compared to a rubber O-ring. This type of seal works very well and is found in many of SMC’s valves.

In some applications, for example high-frequency applications, rubber seal can wear out, and the valves need to be replaced regularly.

SMC offer an optional metal seal for these applica-tions. This option extends the life time of the valve and your application.

A metal seal spool moves in a fixed sleeve, which in turn is rubber sealed against the valve body. The fit be-tween spool and sleeve is very precise.

■ At least 200 million cycles life time. There are docu-mented cases where more than 1 billion cycles have been achieved.

■ Less sensitive to impurities than conventional rubber seal valves.

■ Friction free.■ Air gap between spool and sleeve.■ Highest precision, surface finish, and small gap (1 µm).■ Minimum leakage (slightly more than rubber seal

valve).

Valve series available with metal seal: EVS, SQ, SY, VQ1000/2000/4000, VQ7, VQC and VSS.

SMC’s metal seal valvesValves in high-frequency use often suffer from wear on the seals. SMC’s metal seal valves resist such wear and have superior life time.

Detail of the metal spool inside its sleeve.

Page 11: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

57■

EX500EX260EX250 EX600

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy3000 & -5000 – overview■ SMC’s new SY3000 and SY5000 series is extremely flexible and versatile.■ The high flow rate version enables you in many cases to use a smaller valve than usually.■ See below for an overview of some series with unique advantages.

Cable interface

Fieldbus interface

Flexibility

D-sub/flat cable

Function modules in sandwich format

Mix SY3000 and SY5000 on the same manifold

Easy to change port mode

Circular multipoleL connection Terminal box

Also available in hygienic design. Contact SMC for more information.

Page 12: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

58 ■

5 µm

470 ln/min

SY3100-5u1 74 g

SY3100R-5u1 74 g

SY3101K-5u1 76 gSY3101R-5u1 76 gSY3200-5u1 83 gSY3200R-5u1 83 gSY3201K-5u1 86 gSY3201R-5u1 86 gSY3300-5u1 87 gSY3400-5u1 87 gSY3500-5u1 87 gSY3301K-5u1 90 gSY3401K-5u1 90 gSY3501K-5u1 90 gSY3A00-5u1 83 gSY3B00-5u1 83 gSY3C00-5u1 83 g

SS5Y3-50F1-04D-C6F 4SS5Y3-50F1-06B-C6F 6SS5Y3-50F1-08B-C6F 8SS5Y3-50F1-10B-C6F 10SS5Y3-50F1-12B-C6F 12SS5Y3-51F1-04D-C6F 4SS5Y3-51F1-06D-C6F 6SS5Y3-51F1-08D-C6F 8SS5Y3-51F1-10D-C6F 10SS5Y3-51F1-12D-C6F 12

SS5Y3-10S0-02D-C6 2SS5Y3-10S0-04D-C6 4SS5Y3-10S0-06B-C6 6SS5Y3-10S0-08B-C6 8SS5Y3-10S0-10B-C6 10SS5Y3-10S0-12B-C6 12

SS5Y3-10F1-02D-C6 2SS5Y3-10F1-04D-C6 4SS5Y3-10F1-06B-C6 6SS5Y3-10F1-08B-C6 8SS5Y3-10F1-10B-C6 10SS5Y3-10F1-12B-C6 12

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy3000 – solenoid valve, plug-inMedium Air (dry)

Degree of filtrationMax. working pressure 0.7 MPa (7 bar); high pressure type: 1 MPa (10 bar)

Min. working pressure

5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar); metal seal (not double 3/2): 0.1 MPa (1 bar)

Operating temperature –10 to 50 °C

Voltage/power Standard: 24 VDC ±10% (12 VDC on request)/0.4 W (energy saving 0.1 W)

FlowEnclosure IP40/IP67 depending on choice of electrical connection

■ unmatched flexibility and easy configuration because of new internal connector technology and the ability to mix different sizes in the same manifold

Valve – plug-in, 24 VDC

Part number Type Weight5/2 mono stable, rubber seal5/2 mono stable, rubber seal, external pilot5/2 mono stable, metal seal, high pressure5/2 mono stable, metal seal, external pilot5/2 bi stable, rubber seal5/2 bi stable, rubber seal, external pilot5/2 bi stable, metal seal, high pressure5/2 bi stable, metal seal, external pilot5/3 closed center, rubber seal5/3 exhausted center, rubber seal5/3 pressurized center, rubber seal5/3 closed center, metal seal, high pressure5/3 exhausted center, metal seal, high press.5/3 pressurized center, metal seal, high press.Double 3/2 nC/nC, rubber sealDouble 3/2 nO/nO, rubber sealDouble 3/2 nC/nO, rubber seal

All versions available with external pilot supply. Contact SMC for delivery times.

Metal sub plate for D-sub connection – Ø6 mm, add valves and D-sub cable

Part number Valve stations TypeSide portedSide portedSide portedSide portedSide portedBottom portedBottom portedBottom portedBottom portedBottom ported

Valve manifold for fieldbus – circular and L connection, Ø6 mm, add valves and electrical connector

Part number Valve stations TypeSide portedSide portedSide portedSide portedSide portedSide ported

Valve manifold for D-sub connection – Ø6 mm, add valves and D-sub cable

Part number Valve stations TypeSide portedSide portedSide portedSide portedSide portedSide ported

Valve, plug-in

Valve manifold, fieldbus Valve manifold, D-subSub plate, side ported Sub plate, bottom ported

Page 13: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

59■

SY30M-2-1SA-C4 SY30M-2-1SA-C6 SY30M-2-1DA-C4 SY30M-2-1DA-C6

SY30M-1-1A-C8 —SY30M-1-1AS-C8SY30M-1-1AR-C8

SY30M-1-11A1-C8 —SY30M-1-11AS1-C8SY30M-1-11AR1-C8

SY30M-3-1A-C8 —SY30M-3-1AS-C8SY30M-3-1AR-C8

SY30M-38-1A-C6 Ø6 mm

SY30M-39-1A-C6 Ø6 mm

SY30M-26-1ASY30M-26-2A

SY30M-15-1A

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Manifold bottom plate – side ported

Part number TypeSingle solenoid, Ø4 mmSingle solenoid, Ø6 mmDouble solenoid, Ø4 mmDouble solenoid, Ø6 mm

End plate D-side for fieldbus – circular and L connection, with supply and exhaust, side ported, Ø8 mm

Part number Type

Built-in silencerExternal pilot

Sy3000 – solenoid valve, plug-in

replacement & extension parts

End plate D-side for D-sub connection – with supply and exhaust, side ported, Ø8 mm

Part number Type

Built-in silencerExternal pilot

End plate u-side – with supply and exhaust, side ported, Ø8 mm

Part number Type

Built-in silencerExternal pilot

Individual P-supply – for individual valve

Part number Type

Individual exhaust – for individual valve

Part number Type

Manifold bottom plate End plate D-side, fieldbus End plate D-side, D-sub

Individual P-supply Individual exhaust DIN rail mountBlanking plate

End plate U-side

Blanking plate – for unused valve stations

Part number TypeFor valve manifoldFor metal sub plate

DIn rail mount – for manifold, 1 mount per pack

Part number

Page 14: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

60 ■

SY30M-14-4A-1-2SY30M-14-4A-1-3SY30M-14-4A-1-4SY30M-14-4A-1-6

SY30M-14-4A-2-3

SY30M-14-4A-3-3

SY30M-14-5AAXT100-MC26AXT100-MC26-015AXT100-MC26-030AXT100-MC26-050AXT100-MC26-080

VVZS3000-21A-2*VVZS3000-21A-3*VVZS3000-21A-4*

VVQC1000-T0-1

SY30M-50-1A

SY30M-24-1A

SY30M-60-1A

SY30M-40-1ASY30M-40-2A

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy3000 – solenoid valve, plug-in

replacement & extension parts

Check valveP-shut-off Double check module Sealing disc

Electrical connectionsl connector cable – 34 wire

Part number TypeConnector with 1,5 m cableConnector with 3 m cableConnector with 5 m cableConnector with 10 m cable

l connector cable – 17 wire

Part number TypeConnector with 3 m cable

l connector cable – 9 wire

Part number TypeConnector with 3 m cable

Circular connector – 26-pin (IP67)

Part number TypeCircular connectorConnector onlyConnector with 1,5 m cableConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

D-sub cable with connector – 25-pin, in accordance with MIL-norm (0,3 mm2)

Part number TypeConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

terminal box – suitable for same manifolds as fieldbus connection

Part number Type20 connections (IP67)

P-shut-off – for individual valve

Part number

Check valve – for exhaust channels

Part number

Double check module – maintains correct position during long stops

Part number

Sealing discPart number Type

For P-supply (2 different pressures in manifold)For exhaust (2 different exhausts in manifold)

Fieldbus – all SI-units can be used with manifolds for fieldbus, see chapter 5

For other versions, contact SMC.

Circular connector, connector with cable

L connector cable

Circular connector, connector onlyCircular connector

D-sub cable with connector

Page 15: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

61■

5 µm

1060 ln/min

SY5100-5u1 82 g

SY5100R-5u1 82 g

SY5101K-5u1 91 gSY5101R-5u1 91 gSY5200-5u1 90 gSY5200R-5u1 90 gSY5201K-5u1 101 gSY5201R-5u1 101 gSY5300-5u1 100 gSY5400-5u1 100 gSY5500-5u1 100 gSY5301K-5u1 111 gSY5401K-5u1 111 gSY5501K-5u1 111 gSY5A00-5u1 90 gSY5B00-5u1 90 gSY5C00-5u1 90 g

SS5Y5-10F1-02D-C8 2SS5Y5-10F1-04D-C8 4SS5Y5-10F1-06B-C8 6SS5Y5-10F1-08B-C8 8SS5Y5-10F1-10B-C8 10SS5Y5-10F1-12B-C8 12SS5Y5-11F1-02D-C8 2SS5Y5-11F1-04D-C8 4SS5Y5-11F1-06B-C8 6SS5Y5-11F1-08B-C8 8SS5Y5-11F1-10B-C8 10SS5Y5-11F1-12B-C8 12

SS5Y5-50F1-04D-C8F 4SS5Y5-50F1-06D-C8F 6SS5Y5-50F1-08B-C8F 8SS5Y5-50F1-10B-C8F 10SS5Y5-50F1-12B-C8F 12SS5Y5-51F1-04D-C8F 4SS5Y5-51F1-06D-C8F 6SS5Y5-51F1-08D-C8F 8SS5Y5-51F1-10D-C8F 10SS5Y5-51F1-12D-C8F 12

SS5Y5-10S0-02D-C8 2SS5Y5-10S0-04D-C8 4SS5Y5-10S0-06B-C8 6SS5Y5-10S0-08B-C8 8SS5Y5-10S0-10B-C8 10SS5Y5-10S0-12B-C8 12SS5Y5-11S0-02D-C8 2SS5Y5-11S0-04D-C8 4SS5Y5-11S0-06B-C8 6SS5Y5-11S0-08B-C8 8SS5Y5-11S0-10B-C8 10SS5Y5-11S0-12B-C8 12

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy5000 – solenoid valve, plug-inMedium Air (dry)

Degree of filtrationMax. working pressure 0.7 MPa (7 bar); high pressure type: 1 MPa (10 bar)

Min. working pressure

5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar); metal seal (not double 3/2): 0.1 MPa (1 bar)

Operating temperature –10 to 50 °C

Voltage/power Standard: 24 VDC ±10% (12 VDC on request)/0.4 W (energy saving 0.1 W)

FlowEnclosure IP40/IP67 depending on choice of electrical connection

■ unmatched flexibility and easy configuration because of new internal connector technology and the ability to mix different sizes in the same manifold

Valve – plug-in, 24 VDC

Part number Type Weight5/2 mono stable, rubber seal5/2 mono stable, rubber seal, external pilot5/2 mono stable, metal seal, high pressure5/2 mono stable, metal seal, external pilot5/2 bi stable, rubber seal5/2 bi stable, rubber seal, external pilot5/2 bi stable, metal seal, high pressure5/2 bi stable, metal seal, external pilot5/3 closed center, rubber seal5/3 exhausted center, rubber seal5/3 pressurized center, rubber seal5/3 closed center, metal seal, high pressure5/3 exhausted center, metal seal, high press.5/3 pressurized center, metal seal, high press.Double 3/2 nC/nC, rubber sealDouble 3/2 nO/nO, rubber sealDouble 3/2 nC/nO, rubber seal

All versions available with external pilot supply. Contact SMC for delivery times.Valve manifold for D-sub connection – Ø8 mm, add valves and D-sub cable

Part number Valve stations TypeSide portedSide portedSide portedSide portedSide portedSide portedBottom portedBottom portedBottom portedBottom portedBottom portedBottom ported

Metal sub plate for D-sub connection – Ø8 mm, add valves and D-sub cable

Part number Valve stations TypeSide portedSide portedSide portedSide portedSide portedBottom portedBottom portedBottom portedBottom portedBottom ported

Valve manifold for fieldbus – circular and L connection, Ø8 mm, add valves and electrical connector

Part number Valve stations TypeSide portedSide portedSide portedSide portedSide portedSide portedBottom portedBottom portedBottom portedBottom portedBottom portedBottom ported

Valve, plug-in

Sub plate, side ported Sub plate, bottom ported

Valve manifold, fieldbus, side ported

Valve manifold, D-sub, side ported

Page 16: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

62 ■

SY50M-2-1SA-C6SY50M-2-1SA-C8 SY50M-2-1DA-C6 SY50M-2-1DA-C8 SY50M-2-2SA-C6SY50M-2-2SA-C8SY50M-2-2DA-C6SY50M-2-2DA-C8

SY50M-2-3SA-C6 SY50M-2-3DA-C4 SY50M-2-3DA-C6

SY50M-1-1A-C10 —SY50M-1-1AS-C10SY50M-1-1AR-C10

SY50M-1-11A1-C10 —SY50M-1-11AS1-C10SY50M-1-11AR1-C10

SY50M-3-1A-C10 —SY50M-3-1AS-C10SY50M-3-1AR-C10

SY50M-38-1A-C8 Ø8 mm

SY50M-39-1A-C8 Ø8 mm

SY50M-26-1ASY50M-26-2A

SY50M-15-1A

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Manifold bottom platePart number Type

Single solenoid, Ø6 mm Side portedSingle solenoid, Ø8 mm Side portedDouble solenoid, Ø6 mm Side portedDouble solenoid, Ø8 mm Side portedSingle solenoid, Ø6 mm Bottom portedSingle solenoid, Ø8 mm Bottom portedDouble solenoid, Ø6 mm Bottom portedDouble solenoid, Ø8 mm Bottom ported

Manifold bottom plate – for mixing SY3000/5000, side ported

Part number TypeSingle solenoid, Ø6 mmDouble solenoid, Ø4 mmDouble solenoid, Ø6 mm

Sy5000 – solenoid valve, plug-in

replacement & extension parts

End plate D-side for fieldbus – circular and L connection, with supply and exhaust, side ported, Ø10 mm

Part number Type

Built-in silencerExternal pilot

End plate D-side for D-sub connection – with supply and exhaust, side ported, Ø10 mm

Part number Type

Built-in silencerExternal pilot

End plate u-side – with supply and exhaust, side ported, Ø10 mm

Part number Type

Built-in silencerExternal pilot

Individual P-supply – for individual valve

Part number Type

Individual exhaust – for individual valve

Part number Type

Blanking plate – for unused valve stations

Part number TypeFor valve manifoldFor metal sub plate

DIn rail mount – for manifold, 1 mount per pack

Part number

Manifold bottom plate End plate D-side, fieldbus End plate D-side, D-sub

Individual P-supply Individual exhaust DIN rail mountBlanking plate

End plate U-side

Page 17: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

63■

SY50M-50-1A

SY50M-24-1A

SY50M-60-1A

SV2000-59-2A

SY30M-14-4A-1-2SY30M-14-4A-1-3SY30M-14-4A-1-4SY30M-14-4A-1-6

SY30M-14-4A-2-3

SY30M-14-4A-3-3

SY30M-14-5AAXT100-MC26AXT100-MC26-015AXT100-MC26-030AXT100-MC26-050AXT100-MC26-080

VVZS3000-21A-2*VVZS3000-21A-3*VVZS3000-21A-4*

VVQC1000-T0-1

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy5000 – solenoid valve, plug-in

replacement & extension parts

P-shut-off – for individual valve

Part number

Check valve – for exhaust channels

Part number

Double check module – maintains correct position during long stops

Part number

Sealing discPart number Type

For P-supply and exhaust (2 different pressures in manifold)

Electrical connectionsl connector cable – 34 wire

Part number TypeConnector with 1,5 m cableConnector with 3 m cableConnector with 5 m cableConnector with 10 m cable

l connector cable – 17 wire

Part number TypeConnector with 3 m cable

l connector cable – 9 wire

Part number TypeConnector with 3 m cable

Circular connector – 26-pin (IP67)

Part number TypeCircular connectorConnector onlyConnector with 1,5 m cableConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

D-sub cable with connector – 25-pin, in accordance with MIL-norm (0,3 mm2)

Part number TypeConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

terminal box – suitable for same manifolds as fieldbus connection

Part number Type20 connections (IP67)

Fieldbus – all SI-units can be used with manifolds for fieldbus, see chapter 5

For other versions, contact SMC.

Check valveP-shut-off Double check module Sealing disc

Circular connector, connector with cable

L connector cable

Circular connector, connector onlyCircular connector

D-sub cable with connector

Page 18: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

64 ■

5 µm0.7 MPa (7 bar)

IP40

VQD1151-5MO-Q 34 g

VQD1151-5MO-M5-Q 54 gVQD1151u-5MO-M5-Q 54 g

VV4QD15-02M5F 2 M5VV4QD15-02C4F-Q 2 4 mmVV4QD15-04C4F-Q 4 4 mmVV4QD15-06C4F-Q 6 4 mmVV4QD15-08C4F-Q 8 4 mm

VQD1000-S-M5 M5

VVQD1000-10A-5

AXT661-14An-30 3000 mm

AXT632-7-13

VQD1000-9-1H

VQD11 -5 l

235

M5

M5

5 24 VDC6 12 VDC

5

lO

MO uVW

-1

G1/8

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

VQD1000 – 4/2 solenoid valveMedium Air or neutral gases

Degree of filtrationMax. working pressureMin. working pressure 0.0 MPa (0 bar) (vacuum: –100 kPa)

Operating temperature –10 to 50 °CVoltage/power 24 V/2 W (high flow type: 3.2 W)

Flow 50 ln/min (high flow type: 70 ln/min)Enclosure

Manual override Push button, non-lockableLeD, surge voltage suppressor Standard. Valve has no polarity

■ Direct acting ■ High flow ■ Compact ■ Low weight■ Also for vacuum (leakage ≤ 0.03 cm3/s He) ■ Quick response time – on: 4 ms; off: 2 ms

Valve – 4/2

Part number Type WeightStandard, including screws and gasketStandard, including plateHigh flow valve

Sub platePart number Stations Connection

Single sub platePart number Connection

Blanking plate – with screws and gasket

Part number

Connector – standard with cable

Part number Cable length

Valve mounting screw – M1.7 × 18 (spare part)

Part number

Gasket – between valve and manifold (spare part)

Part number

Part number: valve

Body type

Body ported (single assembly)Body ported (manifold assembly)Plate assembly

Port size

Body port M5 threadPlate assembly

Without sub plateM5 thread

Electrical connection

L connector without cable, with LED and surge voltage suppressorM connector without cable, with LED and surge voltage suppressor

Valve options

Standard, 2 WHigh flow type, 3.2 W1

Vacuum, 2 WHigh flow type vacuum, 3.2 W1

1. Energy saving circuit.

Valve Sub plate Blanking plate

rated voltage

Page 19: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

65■

5 µm0.7 MPa (7 bar)

98 ln/min

SYj3143-5LOu-Q 37 gSYj3243-5LOu-Q 55 gSYj3343-5LOu-Q 58 gSYj3443-5LOu-Q 58 gSYj3543-5LOu-Q 58 g

SYj3143-5WAOu-Q 41 gSYj3243-5WAOu-Q 63 gSYj3343-5WAOu-Q 66 gSYj3443-5WAOu-Q 66 gSYj3543-5WAOu-Q 66 g

DXT060-67-01 Rc1/8

SY100-30-4A-6 600 mmSY100-30-4A-30 3000 mm

SY100-68-A-6 600 mmSY100-68-A-30 3000 mm

WX-83S-6 600 mmWX-83S-20 2000 mm

V111-5LOu 24 VDCV111-5WAOu M8, IP65 24 VDC

SY114-5LOu-Q IP50 24 VDC

G1/8

SYj3123-5LOZ-M3-Q M3

SYj3000-22-1-Q M5

SS5Yj3-S41-02-M5F-Q 2 M5SS5Yj3-S41-02-C4F-Q 2 Ø4SS5Yj3-S41-04-M5F-Q 4 M5SS5Yj3-S41-04-C4F-Q 4 Ø4SS5Yj3-S41-06-M5F-Q 6 M5SS5Yj3-S41-06-C4F-Q 6 Ø4SS5Yj3-S41-08-M5F-Q 8 M5SS5Yj3-S41-08-C4F-Q 8 Ø4

SYj3000-21-2A-Q

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

SyJ3000 – solenoid valveMedium Air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar)

Operating temperature up to 50 °CVoltage/power 24 VDC (other voltages on request)/0.4 W

FlowEnclosure Standard: IP50 (IP65 with M8 connector)

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard

■ Extremely compact ■ Low power consumption

Valve – 5/2, 5/3, standard IP50, for sub plate assembly

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Valve – 5/2, 5/3 with M8 connector IP65, for sub plate assembly

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Blanking plug – for P-, R-channel

Part number Connection

Connector – standard IP50 with cable

Part number Cable length

Connector – covered IP50 with cable

Part number Cable length

Connector – for M8 connection (IP65)

Part number Cable length

For more cable types, see chapter 5.

Pilot valve – spare part for valve with blue manual override button, new type

Part number Type VoltageStandard IP50

Pilot valve – spare part for valve with orange manual override button, old type

Part number Type Voltage

New SY – blue manual override button

Old SY – orange manual override button

Sub plate

M5 × 0.8 alt. C4

1 not used3 –+ (minus or plus)4 +– (plus or minus)

Wiring for M8 (WAOU)

Valve – 5/2, standard IP50, for individual assembly (body ported)

Part number Connection

For more types or M8 connection, contact SMC.

Single sub plate Part number Connection

Sub platePart number Stations Connection

Blanking plate – for S41, with screws and gasket

Part number

For individual assembly

1 3

4

Page 20: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

66 ■

5 µm0.7 MPa (7 bar)

SYj5123-5LOu-M5-Q 47 gSYj5223-5LOu-M5-Q 66 gSYj5323-5LOu-M5-Q 75 gSYj5423-5LOu-M5-Q 75 gSYj5523-5LOu-M5-Q 75 g

SYj5123-5WAOu-M5-Q 51 gSYj5223-5WAOu-M5-Q 74 gSYj5323-5WAOu-M5-Q 85 gSYj5423-5WAOu-M5-Q 85 gSYj5523-5WAOu-M5-Q 85 g

SYj5123-5YZ-M5-Q 68 gSYj5223-5YZ-M5-Q 108 gSYj5323-5YZ-M5-Q 119 gSYj5423-5YZ-M5-Q 119 gSYj5523-5YZ-M5-Q 119 g

SS5Yj5-20-02-00F-Q 2 70 gSS5Yj5-20-04-00F-Q 4 118 gSS5Yj5-20-06-00F-Q 6 166 gSS5Yj5-20-08-00F-Q 8 214 gSS5Yj5-20-10-00F-Q 10 262 g

SYj5143-5LOu-Q 45 gSYj5243-5LOu-Q 62 gSYj5343-5LOu-Q 73 gSYj5443-5LOu-Q 73 gSYj5543-5LOu-Q 73 g

SYj5143-5WAOu-Q 51 gSYj5243-5WAOu-Q 74 gSYj5343-5WAOu-Q 85 gSYj5443-5WAOu-Q 85 gSYj5543-5WAOu-Q 85 g

SYj5143-5YZ-Q 68 gSYj5243-5YZ-Q 108 gSYj5343-5YZ-Q 119 gSYj5443-5YZ-Q 119 gSYj5543-5YZ-Q 119 g

SYj5000-22-1F-Q G1/8

SS5Yj5-41-02-M5F-Q 2 M5 86 gSS5Yj5-42-02-C6F-Q 2 Ø6 86 gSS5Yj5-41-04-M5F-Q 4 M5 148 gSS5Yj5-42-04-C6F-Q 4 Ø6 148 gSS5Yj5-41-06-M5F-Q 6 M5 210 gSS5Yj5-42-06-C6F-Q 6 Ø6 210 gSS5Yj5-41-08-M5F-Q 8 M5 272 gSS5Yj5-42-08-C6F-Q 8 Ø6 272 gSS5Yj5-41-10-M5F-Q 10 M5 334 gSS5Yj5-42-10-C6F-Q 10 Ø6 334 g

SYj5000-21-5ASYj5000-21-6A

DXT060-67-01 Rc1/8SY5000-9-1 Rc1/4

G1/8

G1/8

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

SyJ5000 – solenoid valveMedium Air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.15 MPa (1.5 bar)

Operating temperature up to 50 °CVoltage/power 24 VDC (other voltages on request)/0.4 W

Flow Individual assembly 196 ln/min; plate assembly 245 ln/minEnclosure IP50 (IP65 with M8 or DIn connector)

Manual override Standard: non-lockable, lockable on request.LeD, surge voltage suppressor Standard

■ Low weight and power consumption

Valve – individual or manifold assembly

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With M8 connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With DIn connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Manifold plate – type 20

Part number Stations Weight

Valve – plate assembly

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With M8 connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With DIn connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Single sub platePart number Connection

Sub plate – type 41 and 42

Part number Stations Connection Weight

Blanking plate – with screws and gasket

Part number PassarManifold plate type 20Sub plate type 41 and 42

Blanking plug – for P-, R-channel

Part number Connection

Manifold plate

Single sub plate Sub plate

Type 41: G1/8 Type 42: G1/4

For individual or manifold assembly

Page 21: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

67■

V111-5LOu 24 VDCV111-5WAOu 24 VDCV115-5YZ 24 VDCV115-6YZ 12 VDCV115-3YZ 110 VACV115-4YZ 230 VAC

SY114-5LOu-Q 24 VDCSY115-5YZ 24 VDC

SY100-30-4A-6 600 mmSY100-30-4A-30 3000 mm

SY100-68-A-6 600 mmSY100-68-A-30 3000 mm

WX-83S-6 600 mmWX-83S-20 2000 mm

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Pilot valve – spare part for valve with blue (and yellow) manual override button, new type

Part number Type VoltageStandard (LOu)M8 connector (WAOu)DIn connector (YZ)DIn connector (YZ)DIn connector (YZ)DIn connector (YZ)

Pilot valve – spare part for valve with orange manual override button, old type

Part number Type VoltageStandard (LOu)DIn connector (YZ)

Connector – standard IP50 with cable

Part number Cable length

Connector – covered IP50 with cable

Part number Cable length

Connector – for M8 connection (IP65)

Part number Cable length

For more cable types, see chapter 5.

SyJ5000 – solenoid valve

New SY – blue manual override button

Old SY – orange manual override button

1 not used3 –+ (minus or plus)4 +– (plus or minus)

Wiring for M8 (WAOU)

1 3

4

Page 22: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

68 ■

5 µm0.7 MPa (7 bar)

SYj7123-5LOu-01F-Q 84 gSYj7223-5LOu-01F-Q 96 gSYj7323-5LOu-01F-Q 106 gSYj7423-5LOu-01F-Q 106 gSYj7523-5LOu-01F-Q 106 g

SYj7123-5WAOu-01F-Q 90 gSYj7223-5WAOu-01F-Q 108 gSYj7323-5WAOu-01F-Q 118 gSYj7423-5WAOu-01F-Q 118 gSYj7523-5WAOu-01F-Q 118 g

SYj7123-5YZ-01F-Q 107 gSYj7223-5YZ-01F-Q 142 gSYj7323-5YZ-01F-Q 152 gSYj7423-5YZ-01F-Q 152 gSYj7523-5YZ-01F-Q 152 g

SS5Yj7-21-02-00F-Q 2 214 gSS5Yj7-21-04-00F-Q 4 344 gSS5Yj7-21-06-00F-Q 6 474 gSS5Yj7-21-08-00F-Q 8 604 gSS5Yj7-21-10-00F-Q 10 634 g

SYj7143-5LOu-Q 84 gSYj7243-5LOu-Q 96 gSYj7343-5LOu-Q 106 gSYj7443-5LOu-Q 106 gSYj7543-5LOu-Q 106 g

SYj7143-5WAOu-Q 90 gSYj7243-5WAOu-Q 108 gSYj7343-5WAOu-Q 118 gSYj7443-5WAOu-Q 118 gSYj7543-5WAOu-Q 118 g

SYj7143-5YZ-Q 107 gSYj7243-5YZ-Q 142 gSYj7343-5YZ-Q 152 gSYj7443-5YZ-Q 152 gSYj7543-5YZ-Q 152 g

SYj7000-22-1F-Q G1/8

SS5Yj7-41-02-01F-Q 2 G1/8 400 gSS5Yj7-42-02-C8F-Q 2 Ø8 400 gSS5Yj7-41-04-01F-Q 4 G1/8 600 gSS5Yj7-42-04-C8F-Q 4 Ø8 600 gSS5Yj7-41-06-01F-Q 6 G1/8 800 gSS5Yj7-42-06-C8F-Q 6 Ø8 800 gSS5Yj7-41-08-01F-Q 8 G1/8 1000 gSS5Yj7-42-08-C8F-Q 8 Ø8 1000 gSS5Yj7-41-10-01F-Q 10 G1/8 1200 gSS5Yj7-42-10-C8F-Q 10 Ø8 1200 g

SYj7000-21-1A-1-Q

SY5000-9-1 Rc1/4

G1/4

G1/8

G1/4

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

SyJ7000 – solenoid valveMedium Air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.15 MPa (1.5 bar)

Operating temperature up to 50 °CVoltage/power 24 VDC (other voltages on request)/0.4 W

Flow Individual assembly 589 ln/min; plate assembly 687 ln/minEnclosure IP50 (IP65 with M8 or DIn connector)

Manual override Standard: non-lockable, lockable on requestLeD, surge voltage suppressor Standard

■ Low weight and power consumption

Valve – individual or manifold assembly

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With M8 connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With DIn connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Manifold platePart number Stations Weight

Valve – plate assembly

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With M8 connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With DIn connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Single sub plate Part number Connection

Sub platePart number Stations Ansl. Weight

Blanking plate – with screws and gasket

Part number

Blanking plug – for P-, R-channel

Part number Connection

Single sub plate

Manifold plate

Sub plate

For individual or manifold assembly

Page 23: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

69■

V111-5LOu 24 VDCV111-5WAOu 24 VDCV115-5YZ 24 VDCV115-6YZ 12 VDCV115-3YZ 110 VACV115-4YZ 230 VAC

SY114-5LOu-Q 24 VDCSY115-5YZ 24 VDC

SY100-30-4A-6 600 mmSY100-30-4A-30 3000 mm

SY100-68-A-6 600 mmSY100-68-A-30 3000 mm

WX-83S-6 600 mmWX-83S-20 2000 mm

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Pilot valve – spare part for valve with blue (and yellow) manual override button, new type

Part number Type VoltageStandard (LOu)M8 connector (WAOu)DIn connector (YZ)DIn connector (YZ)DIn connector (YZ)DIn connector (YZ)

Pilot valve – spare part for valve with orange manual override button, old type

Part number Type VoltageStandard (LOu)DIn connector (YZ)

Connector – standard IP50 with cable

Part number Cable length

Connector – covered IP50 with cable

Part number Cable length

Connector – for M8 connection (IP65)

Part number Cable length

For more cable types, see chapter 5.

SyJ7000 – solenoid valve

New SY – blue manual override button

Old SY – orange manual override button

1 not used3 –+ (minus or plus)4 +– (plus or minus)

Wiring for M8 (WAOU)

1 3

4

Page 24: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

70 ■

5 µm0.7 MPa (7 bar)

SY320: 196 ln/min; SY340: 216 ln/min

SY3120-5LOu-M5-Q 51 gSY3220-5LOu-M5-Q 70 gSY3320-5LOu-M5-Q 72 gSY3420-5LOu-M5-Q 72 gSY3520-5LOu-M5-Q 72 g

SY3120-5LOu-C4-Q 51 gSY3220-5LOu-C4-Q 70 gSY3320-5LOu-C4-Q 72 gSY3420-5LOu-C4-Q 72 gSY3520-5LOu-C4-Q 72 g

SY3120-5LOu-C6-Q 51 gSY3220-5LOu-C6-Q 70 gSY3320-5LOu-C6-Q 72 gSY3420-5LOu-C6-Q 72 gSY3520-5LOu-C6-Q 72 g

SY3120-5WAOu-M5-Q 57 gSY3220-5WAOu-M5-Q 82 gSY3320-5WAOu-M5-Q 84 gSY3420-5WAOu-M5-Q 84 gSY3520-5WAOu-M5-Q 84 g

SY3120-5WAOu-C4-Q 67 gSY3220-5WAOu-C4-Q 91 gSY3320-5WAOu-C4-Q 94 gSY3420-5WAOu-C4-Q 94 gSY3520-5WAOu-C4-Q 94 g

SY3120-5WAOu-C6-Q 63 gSY3220-5WAOu-C6-Q 87 gSY3320-5WAOu-C6-Q 90 gSY3420-5WAOu-C6-Q 90 gSY3520-5WAOu-C6-Q 90 g

SX3000-16-1A

SX3000-16-2A

SS5Y3-20-02-00F-Q 2 61 gSS5Y3-20-04-00F-Q 4 87 gSS5Y3-20-06-00F-Q 6 113 gSS5Y3-20-08-00F-Q 8 139 gSS5Y3-20-10-00F-Q 10 165 gSS5Y3-20-12-00F-Q 12 191 g

SY3000-26-19A-Q

DXT060-67-01 Rc1/8

SY3000-38-20A-Q M5

SY3000-39-20A-Q M5

G1/8

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy3000 – solenoid valveMedium Air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar)

Operating temperature up to 50 °C Voltage/power 24 VDC ±10% (other voltages on request)/0.4 W

FlowEnclosure Standard: IP50 (IP65 with M8 connector)

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard

■ Compact: 10 mm ■ High flow: 200 ln/min

Valve – individual or manifold assembly, 24 VDCConnection M5, all ports

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection Ø4, supply and exhaust ports M5

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection Ø6, supply and exhaust ports M5

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

For separate pilot supply (-X20), contact SMC.

Valve – individual or plate assembly, M8 connector (IP65)Connection M5, all ports

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection Ø4, supply and exhaust ports M5

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection Ø6, supply and exhaust ports M5

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Bracket – for individual valve (side bracket)

Part number

Bracket – for individual valve (foot bracket)

Part number

Manifold plate – type 20

Part number Stations Weight

Blanking plate – with screws and gasket

Part number

Blanking plug – for P-, R-channel

Part number Connection

Individual P-supply – for valve on manifold plate type 20, with screws and gasket

Part number Connection

Individual r-exhaust – for valve on manifold plate type 20, with screws and gasket

Part number Connection

Manifold plate

For individual or manifold assembly

Page 25: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

71■

SY3140-5LOu-Q 51 gSY3240-5LOu-Q 69 gSY3340-5LOu-Q 70 gSY3440-5LOu-Q 70 gSY3540-5LOu-Q 70 g

SY3140-5WAOu-Q 57 gSY3240-5WAOu-Q 82 gSY3340-5WAOu-Q 84 gSY3440-5WAOu-Q 84 gSY3540-5WAOu-Q 84 g

SY3000-6A-M5 M5SY3000-6A-C4 SY3000-6A-C6

SY3000-38-2A-Q M5

SY3000-39-2A-Q M5

V111-5LOu 24 VDCV111-5WOu 24 VDC

SY114-5LOu-Q 24 VDC

SY100-30-4A-6 600 mmSY100-30-4A-30 3000 mm

SY100-68-A-6 600 mmSY100-68-A-30 3000 mm

WX-83S-6 600 mmWX-83S-20 2000 mm

SY3000-27-1F-Q

SS5Y3-41-02-M5F-Q 2 110 gSS5Y3-41-04-M5F-Q 4 170 gSS5Y3-41-06-M5F-Q 6 230 gSS5Y3-41-08-M5F-Q 8 290 gSS5Y3-41-10-M5F-Q 10 350 g

SS5Y3-41-02-C6F-Q 2 110 gSS5Y3-41-04-C6F-Q 4 170 gSS5Y3-41-06-C6F-Q 6 230 gSS5Y3-41-08-C6F-Q 8 290 gSS5Y3-41-10-C6F-Q 10 350 gSS5Y3-41-12-C6F-Q 12 410 g

SY3000-26-9A-Q

DXT060-67-01 Rc1/8

KQ2P-04 4KQ2P-06 6KQ2P-08 8KQ2P-10 10

G1/8

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Valve – plate assembly, 24 VDC

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Valve – plate assembly, 24 VDCWith M8 connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Sy3000 – solenoid valve

Connection kit – for SY3000, A-, B-port on valve type 20

Part number Connection

Tubing Ø4 mmTubing Ø6 mm

Individual P-supply – for valve on sub plate type 41, with screws and gasket

Part number Connection

Individual r-exhaust – for valve on sub plate type 41, with screws and gasket

Part number Connection

Pilot valve – spare part for valve with blue (and yellow) manual override button, new type

Part number Type VoltageStandard (LOu)M8 connector (WOu)

Pilot valve – spare part for valve with orange manual override button, old type

Part number Type VoltageStandard (LOu)

Connector – standard IP50 with cable

Part number Cable length

Connector – covered IP50 with cable

Part number Cable length

Connector – for M8 connection

Part number Cable length

For more cable types, see chapter 5.

Single sub platePart number

Sub plate – type 41Connection M5

Part number Stations Weight

Connection Ø6

Part number Stations Weight

up to 20 stations. Different dimensions of cylinder connections can be mixed on type 45-plate. Contact SMC.

Blanking plate – with screws and gasket

Part number

Blanking plug – for P-, R-channel

Part number Connection

Plug – for unused cylinder ports

Part number Plug diameter

New SY – blue manual override button

Old SY – orange manual override button

Sub plate

1 not used3 –+ (minus or plus)4 +– (plus or minus)

Wiring for M8 (WAOU)

1 3

4

Page 26: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

72 ■

5 µm0.7 MPa (7 bar)

SY520: 500 ln/min; SY540: 520 ln/min (5/3: 400 ln/min)

SY5120-5LOu-C6F-Q 91 gSY5220-5LOu-C6F-Q 111 gSY5320-5LOu-C6F-Q 116 gSY5420-5LOu-C6F-Q 116 gSY5520-5LOu-C6F-Q 116 gSY5120-5YZ-C6F-Q 112 gSY5220-5YZ-C6F-Q 153 gSY5320-5YZ-C6F-Q 158 gSY5420-5YZ-C6F-Q 158 gSY5520-5YZ-C6F-Q 158 gSY5120-5WAOu-C6F-Q 116 gSY5220-5WAOu-C6F-Q 161 gSY5320-5WAOu-C6F-Q 166 gSY5420-5WAOu-C6F-Q 166 gSY5520-5WAOu-C6F-Q 166 g

SY5120-5LOu-C8F-Q 82 gSY5220-5LOu-C8F-Q 103 gSY5320-5LOu-C8F-Q 108 gSY5420-5LOu-C8F-Q 108 gSY5520-5LOu-C8F-Q 108 gSY5120-5YZ-C8F-Q 103 gSY5220-5YZ-C8F-Q 145 gSY5320-5YZ-C8F-Q 150 gSY5420-5YZ-C8F-Q 150 gSY5520-5YZ-C8F-Q 150 gSY5120-5WAOu-C8F-Q 107 gSY5220-5WAOu-C8F-Q 153 gSY5320-5WAOu-C8F-Q 158 gSY5420-5WAOu-C8F-Q 158 gSY5520-5WAOu-C8F-Q 158 g

SY5120-5LOu-01F-Q 72 gSY5220-5LOu-01F-Q 93 gSY5320-5LOu-01F-Q 98 gSY5420-5LOu-01F-Q 98 gSY5520-5LOu-01F-Q 98 gSY5120-5YZ-01F-Q 93 gSY5220-5YZ-01F-Q 135 gSY5320-5YZ-01F-Q 140 gSY5420-5YZ-01F-Q 140 gSY5520-5YZ-01F-Q 140 gSY5120-5WAOu-01F-Q 97 gSY5220-5WAOu-01F-Q 143 gSY5320-5WAOu-01F-Q 148 gSY5420-5WAOu-01F-Q 148 gSY5520-5WAOu-01F-Q 148 g

G1/4

SS5Y5-20-02-00F-Q 2 136 gSS5Y5-20-04-00F-Q 4 208 gSS5Y5-20-06-00F-Q 6 280 gSS5Y5-20-08-00F-Q 8 352 gSS5Y5-20-10-00F-Q 10 424 gSS5Y5-20-12-00F-Q 12 496 g

SY5000-26-1A-Q

SY5000-9-1 Rc1/4

SX5000-16-1A

SX5000-16-2A

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy5000 – solenoid valveMedium Air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar)

Operating temperature up to 50 °CVoltage/power 24 VDC ±10% (other voltages on request)/0.4 W

Flow Enclosure Standard: IP50 (IP65 with M8 or DIn connector)

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard

■ Compact: 15 mm ■ High flow: 500 ln/min

Valve – individual or manifold assembly, 24 VDCConnection Ø6, supply and exhaust ports G1/8

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection Ø8, supply and exhaust ports G1/8

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Valve – individual or manifold assembly, 24 VDCConnection G1/8, all ports

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

For separate pilot supply (-X20), contact SMC.

Manifold plate

Manifold plate – type 20

Part number Stations Weight

Blanking plate – with screws and gasket

Part number

Blanking plug – for P-, R-channel

Part number Connection

Bracket – for individual valve (side bracket)

Part number

Bracket – for individual valve (foot bracket)

Part number

For individual or manifold assembly

Page 27: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

73■

SY5140-5LOu-Q 61 gSY5240-5LOu-Q 81 gSY5340-5LOu-Q 87 gSY5440-5LOu-Q 87 gSY5540-5LOu-Q 87 gSY5140-5YZ-Q 82 gSY5240-5YZ-Q 123 gSY5340-5YZ-Q 129 gSY5440-5YZ-Q 129 gSY5540-5YZ-Q 129 gSY5140-5WAOu-Q 65 gSY5240-5WAOu-Q 89 gSY5340-5WAOu-Q 95 gSY5440-5WAOu-Q 95 gSY5540-5WAOu-Q 95 g

SS5Y5-41-02-01F-Q 2 223 gSS5Y5-41-04-01F-Q 4 345 gSS5Y5-41-06-01F-Q 6 467 gSS5Y5-41-08-01F-Q 8 589 gSS5Y5-41-10-01F-Q 10 711 gSS5Y5-41-12-01F-Q 12 833 g

SS5Y5-41-02-C8F-Q 2 223 gSS5Y5-41-04-C8F-Q 4 345 gSS5Y5-41-06-C8F-Q 6 467 gSS5Y5-41-08-C8F-Q 8 589 gSS5Y5-41-10-C8F-Q 10 711 gSS5Y5-41-12-C8F-Q 12 833 g

G1/4

SY5000-6A-C6 SY5000-6A-C8 SY5000-6A-01F G1/8

SY5000-38-1A-Q R1/8

SY5000-39-1A-Q R1/8

SY5000-38-16FA-Q R1/8

SY5000-39-16FA-Q R1/8

SY114-5LOu-Q 24 VDC

V111-5LOu 24 VDCV111-5WOu 24 VDC

KQ2P-04 4KQ2P-06 6KQ2P-08 8KQ2P-10 10

SY100-30-4A-6 600 mmSY100-30-4A-30 3000 mm

SY100-68-A-6 600 mmSY100-68-A-30 3000 mm

WX-83S-6 600 mmWX-83S-20 2000 mm

SY5000-26-2A-Q

SY5000-9-1 Rc1/4

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Valve – plate assembly, 24 VDC

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center5/2 mono stable5/2 bi stable 5/3 closed center5/3 exhausted center5/3 pressurized center

Sub plate – type 41Connection G1/8

Part number Stations Weight

Connection Ø8

Part number Stations Weight

up to 20 stations. Different dimensions of cylinder connections can be mixed on type 45-plate. Contact SMC.

Sy5000 – solenoid valve

Sub plate

Connection kit – for SY5000, A-, B-port on valve type 20

Part number ConnectionTubing Ø6 mmTubing Ø8 mm

Individual P-supply – for valve on manifold plate type 20, with screws and gasket

Part number Connection

Individual r-exhaust – for valve on manifold plate type 20, with screws and gasket

Part number Connection

Individual P-supply – for valve on sub plate type 41, with screws and gasket

Part number Connection

Individual r-exhaust – valve on sub plate type 41, with screws and gasket

Part number Connection

Pilot valve – spare part for valve with orange manual override button, old type

Part number Type VoltageStandard (LOu)

Pilot valve – spare part for valve with blue (and yellow) manual override button, new type

Part number Type VoltageStandard (LOu)M8 connector (WOu)

Plug – for unused cylinder ports

Part number Plug diameter

Connector – standard IP50 with cable

Part number Cable length

Connector – covered IP50 with cable

Part number Cable length

Connector – for M8 connection

Part number Cable length

For more cable types, see chapter 5.

Blanking plate – with screws and gasket

Part number

Blanking plug – for P-, R-channel

Part number Connection

New SY – blue manual override button

Old SY – orange manual override button

1 not used3 –+ (minus or plus)4 +– (plus or minus)

Wiring for M8 (WAOU)

1 3

4

Page 28: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

74 ■

5 µm0.7 MPa (7 bar)

SY7120/7220: 882 ln/min; SY7320/7420: 650 ln/min

SY7120-5YZ-C8F-Q 131 gSY7220-5YZ-C8F-Q 174 gSY7320-5YZ-C8F-Q 182 gSY7420-5YZ-C8F-Q 182 gSY7520-5YZ-C8F-Q 182 g

SY7120-5WAOu-C8F-Q 135 gSY7220-5WAOu-C8F-Q 182 gSY7320-5WAOu-C8F-Q 190 gSY7420-5WAOu-C8F-Q 190 gSY7520-5WAOu-C8F-Q 190 g

SY7120-5YZ-C10F-Q 126 gSY7220-5YZ-C10F-Q 169 gSY7320-5YZ-C10F-Q 177 gSY7420-5YZ-C10F-Q 177 gSY7520-5YZ-C10F-Q 177 g

SY7120-5WAOu-C10F-Q 130 gSY7220-5WAOu-C10F-Q 177 gSY7320-5WAOu-C10F-Q 185 gSY7420-5WAOu-C10F-Q 185 gSY7520-5WAOu-C10F-Q 185 g

SY7120-5YZ-02F-Q 125 gSY7220-5YZ-02F-Q 167 gSY7320-5YZ-02F-Q 175 gSY7420-5YZ-02F-Q 175 gSY7520-5YZ-02F-Q 175 g

SY7120-5WAOu-02F-Q 129 gSY7220-5WAOu-02F-Q 175 gSY7320-5WAOu-02F-Q 183 gSY7420-5WAOu-02F-Q 183 gSY7520-5WAOu-02F-Q 183 g

SX7000-16-1A

G1/4

SS5Y7-20-02-00F-Q 2 150 gSS5Y7-20-04-00F-Q 4 236 gSS5Y7-20-06-00F-Q 6 322 gSS5Y7-20-08-00F-Q 8 408 gSS5Y7-20-10-00F-Q 10 494 gSS5Y7-20-12-00F-Q 12 580 g

SY7000-26-1A-Q

SX7000-16-2A

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy7000 – solenoid valveMedium Air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar)

Operating temperature up to 50 °CVoltage/power 24 VDC ±10% (other voltages on request)/0.45 W

FlowEnclosure Standard: IP65 with DIn or M8 connector

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard

■ Compact: 18 mm ■ High flow: 900 ln/min ■ DIn connector included in valve

Valve – individual assembly, 24 VDCConnection Ø81, DIn connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection Ø81, M8 connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection Ø101, DIn connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection Ø101, M8 connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection G1/41, DIn connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection G1/41, M8 connector (IP65)

Part number Type Weight5/2 monostable5/2 bi stable 5/3 closed center5/3 exhausted center5/3 pressurized center

1. Note! Exhaust ports = G1/8, supply port 1 (P) = G1/4.

For separate pilot supply (-X20), contact SMC.

Bracket – for individual valve (side bracket)

Part number

Manifold plate

Manifold plate – type 20

Part number Stations Weight

Blanking plate – with screws and gasket

Part number

Bracket – for individual valve (foot bracket)

Part number

For individual assembly

Page 29: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

75■

SY7140-5YZ-Q 113 gSY7240-5YZ-Q 155 gSY7340-5YZ-Q 158 gSY7440-5YZ-Q 158 gSY7540-5YZ-Q 158 gSY7140-5WOu-Q 96 gSY7240-5WOu-Q 121 gSY7340-5WOu-Q 124 gSY7440-5WOu-Q 124 gSY7540-5WOu-Q 124 g

SS5Y7-42-02-02F-Q 2 351 gSS5Y7-42-04-02F-Q 4 551 gSS5Y7-42-06-02F-Q 6 751 gSS5Y7-42-08-02F-Q 8 951 gSS5Y7-42-10-02F-Q 10 1151 gSS5Y7-42-12-02F-Q 12 1351 g

SY7000-26-22A-Q

SY5000-9-1 Rc1/4

SY7000-6A-C8 SY7000-6A-C10 SY7000-6A-02F G1/4

SY7000-38-1FA-Q R1/4

SY7000-39-1FA-Q R1/4

SY7000-38-16FA-Q G1/4

SY7000-39-16FA-Q G1/4

SY115-5YZ-Q 24 VDC

V111-5WOu 24 VDCV115-5YZ 24 VDC

KQ2P-04 4 mmKQ2P-06 6 mmKQ2P-08 8 mmKQ2P-10 10 mm

K41K43

WX-83S-6 600 mmWX-83S-20 2000 mm

G1/4

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Valve – plate assembly, 24 VDC

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Supplied complete with connector, LED and surge voltage suppressor.

Sub plate – type 42, connection G1/4

Part number Stations Weight

up to 20 stations.

Blanking plate – with screws and gasket

Part number

Blanking plug – for P, R connection

Part number Connection

Connection kit – for SY7000

Part number ConnectionTubing Ø8 mmTubing Ø10 mm

Individual P-supply – for valve on manifold plate type 20, with screws and gasket

Part number Connection

Individual r-exhaust – for valve on manifold plate type 20, with screws and gasket

Part number Connection

Individual P-supply – for valve on sub plate type 42, with screws and gasket

Part number Connection

Individual r-exhaust – for valve on sub plate type 42, with screws and gasket

Part number Connection

Pilot valve – spare part for valve with orange manual override button, old type

Part number Type VoltageDIn connector (YZ)

Pilot valve – spare part for valve with blue (and yellow) manual override button, new type

Part number Type VoltageM8 connector (WOu)DIn connector (YZ)

Plug – for unused cylinder ports

Part number Plug diameter

Connector – spare part, DIn43650C

Part number TypeStandard (YZ)LED + surge voltage suppressor, 24 VDC (YZ)

Connector – for M8 connection

Part number Cable length

For more cable types, see chapter 5.

Sy7000 – solenoid valve

New SY – blue manual override button

Old SY – orange manual override button

Sub plate

1 not used3 –+ (minus or plus)4 +– (plus or minus)

Wiring for M8 (WAOU)

1 3

4

Page 30: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

76 ■

G3/8

5 µm0.7 MPa (7 bar)

1700 ln/min

SY9120-5YZ-C12F-Q 289 gSY9220-5YZ-C12F-Q 332 gSY9320-5YZ-C12F-Q 356 gSY9420-5YZ-C12F-Q 356 gSY9520-5YZ-C12F-Q 356 g

SY9120-5WAOu-C12F-Q 293 gSY9220-5WAOu-C12F-Q 340 gSY9320-5WAOu-C12F-Q 364 gSY9420-5WAOu-C12F-Q 364 gSY9520-5WAOu-C12F-Q 364 g

SY9120-5YZ-03F-Q 260 gSY9220-5YZ-03F-Q 303 gSY9320-5YZ-03F-Q 327 gSY9420-5YZ-03F-Q 327 gSY9520-5YZ-03F-Q 327 g

SY9120-5WAOu-03F-Q 264 gSY9220-5WAOu-03F-Q 311 gSY9320-5WAOu-03F-Q 335 gSY9420-5WAOu-03F-Q 335 gSY9520-5WAOu-03F-Q 335 g

SS5Y9-23-02-00F-Q 2SS5Y9-23-04-00F-Q 4SS5Y9-23-06-00F-Q 6SS5Y9-23-08-00F-Q 8SS5Y9-23-10-00F-Q 10SS5Y9-23-12-00F-Q 12SS5Y9-23-14-00F-Q 14SS5Y9-23-16-00F-Q 16

SY9000-26-1A-Q

SY9000-GS-1

SY9000-6A-C8 SY9000-6A-C10 SY9000-6A-C12 SY9000-6A-03F G3/8

SY9000-39-1FA

SY9000-38-1FA-Q

SY9000-61-2A

SY9000-50-1A

SY9000-23-

SY9000-25-1

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Manifold plate, type 23

Sy9000 – solenoid valveMedium Air, lubricated or not lubricated (dry)

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.10 MPa (1.0 bar); 5/3 with center position: 0.20 MPa (2.0 bar)

Operating temperature up to 50 °CVoltage/power 24 VDC ±10% (other voltages on request)/0.45 W

FlowEnclosure Standard: IP65 with DIn or M8 connector

Manual override Standard: non-lockable (lockable on request)LeD, surge voltage suppressor Standard

■ Expandable ALu manifold ■ Replaces VF5000

Valve – individual or manifold assembly type 23Connection Ø121, DIn connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection Ø121, M8 connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

1. Note! Supply and exhaust ports (1, 3, 5) = G1/4.

Valve – individual or manifold assembly type 23Connection G3/81, DIn connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Connection G3/81, M8 connector (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

1. Note! Supply and exhaust ports (1, 3, 5) = G1/4.

Manifold plate – type 23, expandable

Part number Stations

Blanking plate – with screws and gasket

Part number

Valve mounting kit – with screws and gasket

Part number

Connection kit – for SY9000

Part number ConnectionTubing Ø8 mmTubing Ø10 mmTubing Ø12 mm

Individual r-exhaust – for valve on manifold plate type 23, with screws and gasket

Part number

Individual P-supply – for valve on manifold plate type 23, with screws and gasket

Part number

P- or r-blocking disc – for pressure or exhaust zoning

Part number

Station expansion part – for expanding manifold plate

Part number

Note! new tensile bolts required.

Tensile bolt – for assembling manifold plate

Part number

= number of valve stations

nut – for tensile bolt

Part number

For individual or manifold assembly

Page 31: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

77■

SY9140-5YZ-Q 196 gSY9240-5YZ-Q 239 gSY9340-5YZ-Q 263 gSY9440-5YZ-Q 263 gSY9540-5YZ-Q 262 g

SY9140-5WOu-Q 179 gSY9240-5WOu-Q 205 gSY9340-5WOu-Q 229 gSY9440-5WOu-Q 229 gSY9540-5WOu-Q 229 g

SS5y9-43- -

02 20

D05

uDB

rS

rS

C12 -

D

D0

RcF Gn nPTT nPTF

02 1/4"03 3/8"C8

C10 C12 M

-Q

SY9000-26-2A-Q

SY9000-GS-2

SY9000-39-2FA-Q

SY9000-38-2FA-Q

SY9000-57-1A

SY9000-18-2

SY9000-50-2A-C8 8 mmSY9000-50-2A-C10 10 mmSY9000-50-2A-C12 12 mmSY9000-50-2A-02F G1/4SY9000-50-2A-03F G3/8

SY9000-23-

SY9000-25-1

SY9000-30-1A

VVQ4000-50B-C8 8 mmVVQ4000-50B-C10 10 mmVVQ4000-50B-C12 12 mm

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Valve – sub plate assembly type 43With DIn connector

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With M8 connection (IP65)

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Sy9000 – solenoid valve

Part number: sub plate – type 43, expandable

No of valve stations

2 stations 20 stations

P/r port output

u-sideFor 2–10 stations

D-sideBåda For 2–20 stations

Supply/exhaust

Internal pilot (standard)External pilotInternal pilot with built-in silencerExternal pilot with built-in silencer

Options

Direct mountingMounted on DIn railFor mounting on DIn rail

ThreadA/B port size

Push-in, Ø8 mmPush-in, Ø10 mmPush-in, Ø12 mmMixed

Blanking plate – with screws and gasket

Part number

Valve mounting kit – with screws and gasket

Part number

Individual r-exhaust – for valve on sub plate type 43, with screws and gasket

Part number

Individual P-supply – for valve on sub plate type 43, with screws and gasket

Part number

P- or r-blocking disc – for pressure or exhaust zoning

Part number

Valve mounting screw – M3 × 42, nickel plated

Part number

Station expansion part – for expanding sub plate, A/B connection

Part number Connection

Note! new tensile bolts required

Tensile bolt – for assembling sub plate

Part number = number of valve stations

nut – for tensile bolt

Part number

DIn rail mountPart number

Push-in fittingPart number Connection

Sub plate, type 43

1 (P) + 3/5 (R) connectionsØ12 mm

Page 32: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

78 ■

SY9000-58A-02F G1/4SY9000-58A-03F G3/8

SY9000-62-1A

V111-5LOu 24 VDCV111-5WOu 24 VDCV115-5YZ 24 VDC

SY114-5LOu-Q 24 VDCSY115-5YZ-Q 24 VDC

K41K43

WX-83S-6WX-83S-20

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy9000 – solenoid valve

Port block – with female thread for sub plate type 43

Part number Connection

Blanking plug – for P, R connection

Part number

Pilot valve – spare part for valve with blue (and yellow) manual override button, new type

Part number Type VoltageStandard (LOu)M8 connector (WOu)DIn connector (YZ)

Pilot valve – spare part for valve with orange manual override button, old type

Part number Type VoltageStandard (LOu)DIn connector (YZ)

Connector – spare part, DIn43650C

Part number TypeStandard (YZ)LED + surge voltage suppressor, 24 VDC (YZ)

Connector – for M8 connection

Part number TypeFor M8 connection with 0.6 m cableFor M8 connection with 2 m cable

For more cable types, see chapter 5.

New SY – blue manual override button

Old SY – orange manual override button

1 not used3 –+ (minus or plus)4 +– (plus or minus)

Wiring for M8 (WAOU)

1 3

4

Page 33: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

79■

10 µm1 MPa (10 bar)

VF3000: 750–870 ln/min; VF5000: 2450 ln/minIP65

VF3130K-5YOD1-02F 214 gVF3230K-5YOD1-02F 311 gVF3330K-5YOD1-02F 328 gVF3430K-5YOD1-02F 328 gVF3530K-5YOD1-02F 328 g

VV5F3-30-021-00F 2VV5F3-30-041-00F 4VV5F3-30-061-00F 6VV5F3-30-081-00F 8

DXT031-38-5A

V212K-5 24 VDCV212K-4 220 VAC

VF5120K-5YOD1-03F 335 gVF5220K-5YOD1-03F 426 gVF5320K-5YOD1-03F 463 gVF5420K-5YOD1-03F 463 gVF5520K-5YOD1-03F 463 g

VF5120K-5YOE1-03F 335 gVF5220K-5YOE1-03F 426 gVF5320K-5YOE1-03F 463 g

VV5F5-20-021-00F 2VV5F5-20-041-00F 4VV5F5-20-061-00F 6VV5F5-20-081-00F 8

VF5000-70-2A

V212K-5 24 VDCV212K-4 220 VAC

X31X32X30

VF3140K-5YOD1 228 gVF3240K-5YOD1 324 gVF3340K-5YOD1 342 gVF3440K-5YOD1 342 g

VV5F3-40-022-02F 2VV5F3-40-042-02F 4VV5F3-40-062-02F 6VV5F3-40-082-02F 8

X31X32X30

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

VF3000 & -5000 – solenoid valveMedium Air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.15 MPa (1.5 bar)

Operating temperature –10 to 50 °C

Voltage/power 24 VDC –15 to +10% (other voltages on request)/1.5 W

FlowEnclosure

Manual override LockableLeD, surge voltage suppressor See connectors

■ Robust design ■ G1/4 ≈ 1000 ln/min ■ G3/8 ≈ 2500 ln/min

Valve VF3000 – individual assembly, ports on valve, G1/4, 24 VDC

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

For 220 VAC, replace 5YOD1 with 4YOD1. Example: VF3130K-4yOD1-02F.

Manifold plate – for VF3000

Part number number of stations

Blanking plate – with screws and gaskets

Part number

Pilot valve – spare part

Part number Type

Valve VF5000 – individual assembly, ports on valve, G3/8, 24 VDC

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With push/turn manual override

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center

For 220 VAC, replace 5YOD/E1 with 4YOD/E1. Example: VF5520K-4yOD1-03F.

Manifold plate – for VF5000

Part number number of stations

Blanking plate – with screws and gaskets

Part number

Pilot valve – spare part

Part number Type

ConnectorPart number Type

StandardLED + surge voltage suppressor, 24 VDCLight + surge voltage suppressor, 220 VAC

Note! Connector ordered separately.

Valve VF3000 – for plate assembly, ports in plate, 24 VDC

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center

For 220 VAC, replace 5YOD1 with 4YOD1. Example: VF3140K-4yOD1.

Sub plate – for VF3000, cylinder port G1/4

Part number number of stations

ConnectorPart number Type

StandardLED + surge voltage suppressor, 24 VDCLight + surge voltage suppressor, 220 VAC

Note! Connector ordered separately.

Ports on valve

Ports in plate

Page 34: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

80 ■

5 µm0.7 MPa (7 bar)

170 ln/min

SY3160-5LOu-C6-Q 51 gSY3260-5LOu-C6-Q 73 gSY3360-5LOu-C6-Q 76 gSY3460-5LOu-C6-Q 76 gSY3560-5LOu-C6-Q 76 g

SY3160-5WAOu-C6-Q 55 gSY3260-5WAOu-C6-Q 81 gSY3360-5WAOu-C6-Q 84 gSY3460-5WAOu-C6-Q 84 gSY3560-5WAOu-C6-Q 84 g

SY3000-55-1A-Q Ø8 mm

➌➍

SY3000-56-1A-QSY3000-56-1B-Q

SY3000-52-5A

SS5Y3-60-02D-Q 2 110 gSS5Y3-60-04D-Q 4 170 gSS5Y3-60-06D-Q 6 230 gSS5Y3-60-08D-Q 8 290 gSS5Y3-60-10D-Q 10 350 gSS5Y3-60-12B-Q 12 410 g

SY3000-52-6A

SY3000-6A-M5 M5SY3000-6A-C4 Ø4 mmSY3000-6A-C6 Ø6 mm

SY100-30-4ASY100-30-4A-6SY100-30-4A-10SY100-30-4A-15SY100-30-4A-20SY100-30-4A-25SY100-30-4A-30SY100-30-4A-50SY100-68-A-6SY100-68-A-30V100-49-1-1V100-49-1-2V100-49-1-3V100-49-1-4V100-49-1-5

SY114-5LOu-QV111-5LOu

V111-5WAOu

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy3060 – valve manifold, cassette typeMedium Compressed air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar)

Operating temperature up to 50 °C

Voltage/power Standard: 24 VDC ±10% (other voltages on request)/0.4 W (low power: 0.1 W)

FlowEnclosure IP50 or IP65 (M8 connector)

Manual override Standard: lockable (push)LeD, surge voltage suppressor Standard

■ Compact, low weight ■ Extremely simple and flexible ■ Few parts to stock

D-side

u-side

Valve – cassette type, 24 VDC, connection Ø6 mm, IP50

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Valve – M8 connector, 24 VDC, connection Ø6 mm, IP65

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Also available with M5 thread and connection Ø4 mm.

Supply and exhaust blockPart number Connection

Includes gaskets SY3000-52-5A.

End plates, D- and u-sidePart number Description

End plate, D-sideEnd plate, u-side

Gaskets – 3 st

Part number

Manifold assembly kit – includes supply and exhaust block, end plates and DIn rail

Part number Stations Weight

Plug kitPart number Description

Plugs for channel 1, 3 and 5

Connection kit – A and B port

Part number Connection

ConnectorPart number Description

0.3 m cable0.6 m cable1 m cable1.5 m cable2 m cable2.5 m cable3 m cable5 m cable0.6 m cable, covered, IP50 enclosure3 m cable, covered, IP50 enclosureM8, 0.3 m cableM8, 0.5 m cableM8, 1 m cableM8, 2 m cableM8, 5 m cable

Pilot valve – 24 VDC

Part number DescriptionFor valve with orange manual override buttonFor valve with blue manual override buttonM8 connector, for valve with blue manual over-ride button

➌➋

➎➋

Page 35: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

81■

5 µm0.7 MPa (7 bar)

450 ln/min

SY5160-5LOu-C6-Q 88 gSY5260-5LOu-C6-Q 111 gSY5360-5LOu-C6-Q 117 gSY5460-5LOu-C6-Q 117 gSY5560-5LOu-C6-Q 117 g

SY5160-5LOu-C8-Q 80 gSY5260-5LOu-C8-Q 103 gSY5360-5LOu-C8-Q 109 gSY5460-5LOu-C8-Q 109 gSY5560-5LOu-C8-Q 109 g

SY5160-5DZ-01F-Q 90 gSY5260-5DZ-01F-Q 136 gSY5360-5DZ-01F-Q 142 gSY5460-5DZ-01F-Q 142 gSY5560-5DZ-01F-Q 142 g

SY5160-5WAOu-01F-Q 71 gSY5260-5WAOu-01F-Q 102 gSY5360-5WAOu-01F-Q 108 gSY5460-5WAOu-01F-Q 108 gSY5560-5WAOu-01F-Q 108 g

SY5000-55-1A-Q Ø10 mm

➌➍

SY5000-56-1A-QSY5000-56-1B-Q

SY5000-52-3A

SS5Y5-60-02D-Q 2 141 gSS5Y5-60-04D-Q 4 145 gSS5Y5-60-06D-Q 6 150 gSS5Y5-60-08D-Q 8 154 gSS5Y5-60-10D-Q 10 159 gSS5Y5-60-12B-Q 12 163 g

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy5060 – valve manifold, cassette typeMedium Compressed air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar)

Operating temperature up to 50 °C

Voltage/power Standard: 24 VDC ±10% (other voltages on request)/0.4 W (low power: 0.1 W)

Flow

Enclosure Standard: IP65 (IP50 on request)

Manual override Standard: lockable (push)LeD, surge voltage suppressor Standard

■ Compact, low weight ■ Extremely simple and flexible ■ Few parts to stock

Valve – cassette type, 24 VDC, connection Ø6 mm, IP65

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Valve – cassette type, 24 VDC, connection Ø8 mm, IP65

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Valve – DIn connector, 24 VDC, connection G1/8, IP65

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Valve – M8 connector, 24 VDC, connection G1/8, IP65

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Supply and exhaust blockPart number Connection

Includes gaskets SY5000-52-3A.

End plates, D- and u-sidePart number Description

End plate, D-sideEnd plate, u-side

Gaskets – 3 st

Part number

Manifold assembly kit – includes supply and exhaust block, end plates and DIn rail

Part number Stations Weight

D-side

u-side

➌➋

➎➋

Page 36: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

82 ■

SY5000-52-4A

SY5000-6A-C6 Ø6 mmSY5000-6A-C8 Ø8 mmSY5000-6A-01F G1/8

SY100-30-4ASY100-30-4A-6SY100-30-4A-10SY100-30-4A-15SY100-30-4A-20SY100-30-4A-25SY100-30-4A-30SY100-30-4A-50SY100-68-A-6SY100-68-A-30SY100-61-3-05V100-49-1-1V100-49-1-2V100-49-1-3V100-49-1-4V100-49-1-5

SY114-5LOu-QV111-5LOu

V115-5DZ

V111-5WAOu

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Plug kitPart number Description

Plugs for channel 1, 3 and 5

Connection kit – A and B port

Part number Connection

Sy5060 – valve manifold, cassette type

ConnectorPart number Description

0.3 m cable0.6 m cable1 m cable1.5 m cable2 m cable2.5 m cable3 m cable5 m cable0.6 m cable, covered, IP50 enclosure3 m cable, covered, IP50 enclosureDIn connector, 24 VDCM8, 0.3 m cableM8, 0.5 m cableM8, 1 m cableM8, 2 m cableM8, 5 m cable

Pilot valve – 24 VDC

Part number DescriptionFor valve with orange manual override buttonFor valve with blue manual override buttonDIn connector, for valve with blue manual over-ride buttonM8 connector, for valve with blue manual over-ride button

Page 37: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

83■

5 µm0.7 MPa (7 bar)

980 ln/min

SY7160-5DZ-02F-Q 126 gSY7260-5DZ-02F-Q 170 gSY7360-5DZ-02F-Q 178 gSY7460-5DZ-02F-Q 178 gSY7560-5DZ-02F-Q 178 g

SY7160-5DZ-C10-Q 146 gSY7260-5DZ-C10-Q 191 gSY7360-5DZ-C10-Q 199 gSY7460-5DZ-C10-Q 199 gSY7560-5DZ-C10-Q 199 g

SY7160-5WAOu-02F-Q 129 gSY7260-5WAOu-02F-Q 157 gSY7360-5WAOu-02F-Q 165 gSY7460-5WAOu-02F-Q 165 gSY7560-5WAOu-02F-Q 165 g

SY7000-75-1A-Q Ø10 mm

➌➍

SY7000-56-1A-QSY7000-56-1B-Q

SY7000-70-1A

SS5Y7-60-02D-Q 2 225 gSS5Y7-60-04D-Q 4 231 gSS5Y7-60-06D-Q 6 237 gSS5Y7-60-08D-Q 8 244 gSS5Y7-60-10D-Q 10 250 gSS5Y7-60-12B-Q 12 256 g

SY7000-70-2A

SY7000-6A-C8 Ø8 mmSY7000-6A-C10 Ø10 mmSY7000-6A-02F G1/4

SY100-61-3-05V100-49-1-1V100-49-1-2V100-49-1-3V100-49-1-4V100-49-1-5

V115-5DZ

V111-5WAOu

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sy7060 – valve manifold, cassette typeMedium Compressed air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar)

Operating temperature up to 50 °C

Voltage Standard: 24 VDC ±10% (other voltages on request)/0.4 W (low power: 0.1 W)

Flow

Enclosure Standard: IP65 (IP50 on request)

Manual override Standard: lockable (push)LeD, surge voltage suppressor Standard

■ Compact, low weight ■ Extremely simple and flexible ■ Few parts to stock

Valve – DIn connector, 24 VDC, connection G1/4, IP65

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Valve – DIn connector, 24 VDC, connection Ø10 mm, IP65

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Valve – M8 connector, 24 VDC, connection G1/4, IP65

Part number Type Weight5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Supply and exhaust blockPart number Connection

Includes gaskets SY7000-70-1A.

End plates, D- and u-sidePart number Description

End plate, D-sideEnd plate, u-side

Gaskets – 3 st

Part number

Manifold assembly kit – includes supply and exhaust block, end plates and DIn rail

Part number Stations Weight

Plug kitPart number Description

Plugs for channel 1, 3 and 5

Connection kit – A and B port

Part number Connection

ConnectorPart number Description

DIn connector, 24 VDCM8, 0.3 m cableM8, 0.5 m cableM8, 1 m cableM8, 2 m cableM8, 5 m cable

Pilot valve – 24 VDC

Part number DescriptionDIn connector, for valve with blue manual override buttonM8 connector, for valve with blue manual override button

D-side

u-side

➌➋

➎➋

Page 38: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

84 ■

5 µm0.7MPa (7bar)

Sj2000: 80 ln/min; Sj3000: 120 ln/minIP50

Sj2160-5Cu-C4Sj2260-5Cu-C4Sj2360-5Cu-C4Sj2460-5Cu-C4Sj2560-5Cu-C4Sj2A60-5Cu-C4 5/4, 2 × 3/2, nC nCSj2B60-5Cu-C4 5/4, 2 × 3/2, nO nOSj2C60-5Cu-C4 5/4, 2 × 3/2, nC nO

Sj2160-5MOZ-C4Sj2260-5MOZ-C4Sj2360-5MOZ-C4Sj2460-5MOZ-C4Sj2560-5MOZ-C4Sj2A60-5MOZ-C4 5/4, 2 × 3/2, nC nCSj2B60-5MOZ-C4 5/4, 2 × 3/2, nO nOSj2C60-5MOZ-C4 5/4, 2 × 3/2, nC nO

Sj3160-5Cu-C6Sj3260-5Cu-C6Sj3360-5Cu-C6Sj3460-5Cu-C6Sj3560-5Cu-C6Sj3A60-5Cu-C6 5/4, 2 × 3/2, nC nCSj3B60-5Cu-C6 5/4, 2 × 3/2, nO nOSj3C60-5Cu-C6 5/4, 2 × 3/2, nC nO

Sj3160-5MOZ-C6Sj3260-5MOZ-C6Sj3360-5MOZ-C6Sj3460-5MOZ-C6Sj3560-5MOZ-C6Sj3A60-5MOZ-C6 5/4, 2 × 3/2, nC nCSj3B60-5MOZ-C6 5/4, 2 × 3/2, nO nOSj3C60-5MOZ-C6 5/4, 2 × 3/2, nC nO

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

SJ2000 & -3000 – solenoid valve manifold, plug-in, cassette type

Medium Compressed airDegree of filtration

Max. working pressure

Min. working pressure

5/2 mono stable: 0.15 MPa (1.5 bar)5/2 bi stable: 0.1 MPa (1 bar)5/3 with center position: 0.2 MPa (2 bar)5/4 double 3/2: 0.15 MPa (1.5 bar)

Operating temperature –10 to 50 °C

Voltage/power Standard 24 VDC ±10%; Sj2000: 0.55 W; Sj3000: 0.4 W

FlowEnclosure

Manual override Standard: non-lockable (lockable [push/turn] on request)LeD, surge voltage suppressor LED, diode protection

■ Two valve sizes on same manifold, 7 mm and 10 mm ■ Modern connections between valves (card edge)■ Ideal cost-effective valve system together with fieldbus EX510■ Optional smart features: switch for electrical disconnection of valve; pressure regulator module; valve unit for vacuum/ejection

Valve SJ2000 – plug-in, 24 VDC

Part number Type5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With individual electrical connection

Part number Type5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Valve SJ3000 – plug-in, 24 VDC

Part number Type5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

With individual electrical connection

Part number Type5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center

Since Sj is a new valve series, additional stocking may occur. Contact SMC for current stock status.

Page 39: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

85■

SS5j2-60FD1-02DSS5j2-60FD1-04DSS5j2-60FD1-06DSS5j2-60FD1-08DSS5j2-60FD1-10DSS5j2-60FD1-12B

SS5j3-60FD1-02DSS5j3-60FD1-04DSS5j3-60FD1-06BSS5j3-60FD1-08BSS5j3-60FD1-10BSS5j3-60FD1-12B

SS5j2-60S6BnD-02DSS5j2-60S6BnD-04DSS5j2-60S6BnD-06BSS5j2-60S6BnD-08BSS5j2-60S6BnD-10BSS5j2-60S6BnD-12B

SS5j3-60S6BnD-02DSS5j3-60S6BnD-04DSS5j3-60S6BnD-06BSS5j3-60S6BnD-08BSS5j3-60S6BnD-10BSS5j3-60S6BnD-12B

Sj3000-50-1A-C8

Sj3000-50-1AS-C8

Sj3000-50-1AR-C8

Sj3000-50-1ARS-C8

Sj3000-53-1ASj3000-42-1A-1

Sj3000-42-3A-2

Sj3000-53-2ASj3000-44-1A

Sj3000-155-1A

Sj3000-49-1ASj3000-49-2A

Sj3000-00-P

Sj3000-00-P-H

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Valve manifold – Sj2000, D-sub connector

Part number Type 2 valve stations 4 valve stations 6 valve stations 8 valve stations10 valve stations12 valve stations

Valve manifold – Sj30001, D-sub connector

Part number Type 2 valve stations 4 valve stations 6 valve stations 8 valve stations10 valve stations12 valve stations

1. For mix of Sj2000 and -3000, add “M” in the part number. Example: SS5j3-M60-FD1-02D.

Valve manifold – Sj2000, for fieldbus EX510

Part number Type 2 valve stations 4 valve stations 6 valve stations 8 valve stations10 valve stations12 valve stations

Valve manifold – Sj30001, for fieldbus EX510

Part number Type 2 valve stations 4 valve stations 6 valve stations 8 valve stations10 valve stations12 valve stations

1. For mix of Sj2000 and -3000, add “M” in the part number. Example: SS5j3-M60S6BnD-02D.

SJ2000 & -3000 – solenoid valve manifold, plug-in, cassette type

Valve manifold accessoriesPart number Type

Supply/exhaust block, internal pilotSupply/exhaust block, internal pilot, built-in silencerSupply/exhaust block, external pilotSupply/exhaust block, external pilot, built-in silencerEnd plate for u-sidePower supply block, D-sub, D-sidePower supply block, 20-pin flat cable for EX510, D-sideEnd plate, PC wiring, D-sideBlocking disc, exhaustLabels for indication of supply/exhaust blockBlanking plate for single solenoidBlanking plate for double solenoidPressure regulator block with top-mounted pressure gauge, adjust with screwdriverPressure regulator block with top-mounted pressure gauge, knob for adjusting

Since Sj is a new valve series, additional stocking may occur. Contact SMC for current stock status.

Page 40: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

86 ■

5 µm0.7 MPa (7 bar)

VQC1101n-51 250 ln/min 67 gVQC1100n-51 180 ln/min 67 gVQC1201n-51 250 ln/min 77 gVQC1200n-51 180 ln/min 77 gVQC1301n-51 180 ln/min 77 gVQC1401n-51 250 ln/min 77 gVQC1501n-51 180 ln/min 77 gVQC1A01n-51 160 ln/min 77 gVQC1B01n-51 160 ln/min 77 gVQC1C01n-51 160 ln/min 77 g

VVQ1000-50A-

VVQ1000-52A-C8

An200-KM8

VVQ1000-F-L-

VVQ1000-10A-1

KQ2P-

VVQ0000-58A

VV5QC11-02C6SD0 2VV5QC11-04C6SD0 4VV5QC11-06C6SD0 6VV5QC11-08C6SD0 8VV5QC11-10C6SD0 10VV5QC11-12C6SD0 12

VVQC1000-F25-1VVQC1000-P26-1

VVQC1000-M26-1

VVQC1000-T0-1VVQC1000-L25-0-1VVQC1000-L25-1-1VVQC1000-L25-2-1

B C D

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

VQC1000 – solenoid valve, plug-inMedium Air, lubricated or not lubricated (dry)

Degree of filtrationMax. working pressure

Min. working pressure

5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar); metal seal (not double 3/2): 0.1 MPa (1 bar)

Operating temperature up to 50 °C (dry air)

Voltage/power Standard: 24 VDC ±10% (12 VDC on request)/0.4 W

Flow See table below

Enclosure IP67, factory-assembled in japan; otherwise IP65; D-sub or flat cable, IP50

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard

■ unmatched flexibility and easy configuration because of new internal connector technology

Valve – plug-in, 24 VDC

Part number1 Type Flow Weight5/2 mono stable, rubber seal5/2 mono stable, metal seal5/2 bi stable, rubber seal5/2 bi stable, metal seal5/3 closed center, rubber seal5/3 exhausted center, rubber seal5/3 pressurized center, rubber sealDouble 3/2 nC/nC, rubber sealDouble 3/2 nO/nO, rubber sealDouble 3/2 nC/nO, rubber seal

1. For lockable manual override, add B, C or D at end of part number. Example: VQC1101n-51B.

replacement fittingPart number = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Parallel fitting – 2 valve stations

Part number

Silencer – for exhaust

Part number

90° connectionPart number = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Blanking plate – for unused valve stations

Part number

Blanking plug – in place of unused connections

Part number = 04 for Ø4 mm; 06 for Ø6 mm.

Blanking plug – in place of fitting

Part number

Sub plates – basic type, add electrical connection below

Part number Stations

Additions – for sub plates above

AdditionsBuilt-in silencer (…SD0-S) Manifold 13–24 valve stations/added station1 Separate pilot supply (…SD0-R)/manifold

1. Note! Manifold specification required; contact SMC.

Electrical connections – interface modules

Part number TypeD-sub, 25-pinFlat cable, 26-pinCircular connector, 26-pin (IP67)Terminal box, 20 connections (IP67)Molded cable, 0.6 mMolded cable, 1.5 mMolded cable, 3 m

Fieldbus – EX250, EX260, EX500 and EX600, see chapter 5

Parallel fitting

Manual override versions

Page 41: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

87■

VVQ1000-P-1-C6

VVQ1000-16A

VVQ1000-R-1-C6

VVQC1000-19A-D-C6VVQC1000-19A-S-C6

VVQ1000-18A

VVQC1000-1A-D-C6VVQC1000-1A-S-C6

VVQ1000-n-

VVQ1000-57A

VVZS3000-21A-2*VVZS3000-21A-3*VVZS3000-21A-4*

AXT100-MC26AXT100-MC26-015AXT100-MC26-030AXT100-MC26-050AXT100-MC26-080

VQC 1 10 -➊

1 0 n 5➋ ➌ ➎ ➏➍

➊12345ABC

➋01

B

Knr

➍5 24 VDC1

6 12 VDC

E

B

C

D

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Individual P-supplyPart number

Blocking disc – supply

Part number

Individual r-exhaustPart number

Blocking disc – exhaust

Part number TypeDouble solenoidSingle solenoid

On VVQC1000, entire plate is replaced.

Check valve – prevents back pressure from R-channel

Part number

Expansion part – standard

Part number TypeFor double solenoidFor single solenoid

name platePart number = number of valve stations.

DIn rail brackets – 1 pair

Part number

D-sub connector – 25-pin, in accordance with MIL-norm (0.3 mm2)

Part number TypeConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

Circular connector – 26-pin (IP67), with cable

Part number TypeConnector onlyConnector with 1.5 m cableConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

For output modules VQC1000 – electrical accessories, see EX250/-500 fieldbus.

For other versions, contact SMC.For fieldbus components, see chapter 5.

Part number: valve – for valve manifold, see next page

Series VQC1000

Function

5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized centerDouble 3/2 nC/nC1

Double 3/2 nO/nO1

Double 3/2 nC/nO1

1. Only available with rubber seal.

Seal type

Metal sealRubber seal

Options

Standard (0.4 W)Quick response time (12 ms)1

High pressure (1 MPa)2

negative commonExternal pilot3

When more than one option is desired, enter them in alphabetical order.1. 0.95 W2. Only available with metal seal, 0.95 W.3. not available for double 3/2 valve.

rated voltage

1. Fieldbus connection only available for 24 VDC.

LeD/surge voltage suppressor

WithWithout LED, with surge voltage suppressor1

1. not for fieldbus connection.

Manual override

non-locking push type (tool required)Locking for screwdriver (tool required)Locking type (manual)Locking sliding type (manual)

VQC1000 – solenoid valve, plug-in

Individual P-supply

Blocking disc – supply

Name plate

Individual R-exhaust

Blocking disc – exhaust

Valve stations are numbered in ascending order, starting from D-side

D-side U-sideValve stations 1 2 3 4 5 6 7 8

12

34

5

98

76

Page 42: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

88 ■

➋C3 C4 C6 M5

CM

l3

l4

l6

l5

B3

B4

B6

B5

lM

➊01

FD0FD1FD2FD3PD0PD1PD2PD3

PDC

TD0

lD0lD1lD2MD0MD1MD2MD3

SD0SDA1

SDA2

SD0SDQSDnSDVSDy

SDTA

SDTB

SDTC

SDTD

SDVB

B

D

D

K

nr

S

01 8

123

n nPn (–)

➍EX250 EX500 EX126

Dev

icen

et

Pr

OFI

Bu

S-

DP

CC

-lIn

K

AS

-i

CA

no

pen

Dev

icen

et

Pr

OFI

Bu

S-

DP

CC

-lIn

K

rem

ote

I/O

CC

-lIn

K

+COM — — ✔ — — ✔ ✔ ✔ ✔ ✔n –COM ✔ ✔ — ✔ ✔ ✔ ✔ ✔ ✔ —

VV5QC - 08 B1 1 C6 FD1 F / P T l M/ / /VV5QC - 08 B-1 1 C6 SDQ S

➊ ➋ ➌ ➍ ➎ ➏ ➐ ➑

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Cylinder port size

Push-in, Ø3.2 mmPush-in, Ø4 mmPush-in, Ø6 mmM5 threadMixed sizes or with port plugTop-connected angle with push-in, Ø3.2 mmTop-connected angle with push-in, Ø4 mmTop-connected angle with push-in, Ø6 mmM5 threadBottom-connected angle with push-in, Ø3.2 mmBottom-connected angle with push-in, Ø4 mmBottom-connected angle with push-in, Ø6 mmM5 threadAngle connector, mixed sizes

When selecting CM/LM, enter size in manifold specification sheet.

number of valve stations

1 station

Maximum number of valve stations de-pends on chosen electrical connection. See Electrical connection/cable length.

Electrical connection/cable length

Input D-side Connection/cable length

Valve stations2

F co

nn. D-sub connector (25P) without cable

1 to 12 (24)

D-sub connector (25P) w. 1.5 m cableD-sub connector (25P) w. 3 m cableD-sub connector (25P) w. 5 m cable

P c

onn

.

Flat cable (26P) without cable1 to 12

(24)Flat cable (26P) with 1.5 m cableFlat cable (26P) with 3 m cableFlat cable (26P) with 5 m cable

Flat cable (20P) without cable1 1 to 9 (18)

T c

onn

.

Terminal connection in box 1 to 10 (20)

l co

nn. Cable (25 wire), 0.6 m wire length

1 to 12 (24)Cable (25 wire), 1.5 m wire length

Cable (25 wire), 3 m wire length

M c

onn

. Multipole connector (26P) without cable1 to 12

(24)Multipole connector (26P) with 1.5 m cableMultipole connector (26P) with 3 m cableMultipole connector (26P) with 5 m cable

S c

onn

ecti

on

Distributed fieldbus (EX500)For fieldbus without fieldbus node

1 to 8 (16)

With fieldbus node for Remote I/OWith fieldbus node for Devicenet/ PROFIBuS-DP/CC-LInK

Fieldbus with in- and outputs (EX250)For fieldbus without fieldbus node

1 to 12 (24)

Fieldbus for DevicenetFieldbus for PROFIBuS-DPFieldbus for CC-LInKFieldbus for CAnopenAS-i, 8 in/8 out, 31-slave model, 2 power supplies

1 to 4 (8)

AS-i, 4 in/4 out, 31-slave model, 2 power supplies

1 to 2 (4)

AS-i, 8 in/8 out, 31-slave model, 1 power supply

1 to 4 (8)

AS-i, 4 in/4 out, 31-slave model, 1 power supply

1 to 2 (4)

Fieldbus with outputs (EX126)

Fieldbus for CC-LInK 1 to 8 (16)

1. P connection: Order cables separately for type 20P.2. numbers in paranthesis indicates maximum number of solenoids for configuration w. mixed single-double solenoid connections. Maximum number of valve stations is determined by total number of solenoids. For mixed connections, use option symbol “K”.

Options

noneAll stations with back-pressure check valves1

With DIn rail (rail length: standard)With DIn rail (rail length: special)2

Special wiring (not double wiring)3

With name plateExternal pilot4

Direct exhaust with built-in silencer5

Specify options in alphabetical order. Example: BRS.1. When using backpressure check valves only on neccessary stations, en-ter check valve part number and valve station number in manifold specifica-tion sheet.2. For special DIn rail length, enter D. ( = number of valve stations.) Example: D08. In this case, manifold is mounted on DIn rail for 8 stations, regardless of actual number of stations in manifold. Entered number of stations must be larger than actual number of stations in manifold. Enter D0 for op-tions without DIn rail.3. Ensure that wiring is entered in manifold specification sheet.4. For external pilot option “R”, also enter external pilot option “R” for valves in question.5. Option with built-in silencer does not meet requirement of IP67.

Input block (only entered when

input blocks are used)

Without fieldbus node/input block (SD0)Without input blockWith 1 input block With 8 input blocks

Type of input block (only

entered when input blocks are used)

Without input blockM12, 2 inputsM12, 4 inputsM8, 4 inputs (3 pins)

Polarity, input block (only entered when input blocks

are used)

PnP (+) or without fieldbus node/ input block

Fieldbus polarity

Polarity

Leave box for fieldbus polarity blank for manifold without bus node (SD0).

Part number: valve manifold – for VQC1000 plate assembly/plug-in unit

connection

connection

Series VQC1000

Plate assembly/plug-in

VQC1000 – solenoid valve, plug-in

Page 43: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

89■

EX

250

EX

260

EX

500

EX

600

EX

126

D-s

ub

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Exploded view VQC1000Electrical connection

and fieldbus End plate, D-side Valve station, base End plate, u-side

S c

onn

ecti

on

(fiel

db

us)

F co

nnec

tio

nP

co

nnec

tio

n

Flat

cab

le

T c

onn

ecti

on

Term

inal

con

n.

l co

nnec

tio

n

Sin

gle

wire

M c

onn

ecti

on

Mul

tipol

e co

nn.

VQC1000 – solenoid valve, plug-in

Page 44: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

90 ■

5 µm0.7 MPa (7 bar)

I

VV5QC21-02C8SD0 2VV5QC21-04C8SD0 4VV5QC21-06C8SD0 6VV5QC21-08C8SD0 8VV5QC21-10C8SD0 10VV5QC21-12C8SD0 12

VVQC1000-F25-1VVQC1000-P26-1

VVQC1000-M26-1

VVQC1000-T0-1VVQC1000-L25-0-1VVQC1000-L25-1-1VVQC1000-L25-2-1

VVQ1000-51A-

VVQ2000-52A-C10

An200-KM10

VVQ2000-10A-1

KQ2P-

VVQ1000-58A

VVQ2000-P-1-C8

VQC2101n-51 800 ln/min 95 gVQC2100n-51 600 ln/min 105 gVQC2201n-51 800 ln/min 105 gVQC2200n-51 600 ln/min 105 gVQC2301n-51 600 ln/min 105 gVQC2401n-51 800 ln/min 105 gVQC2501n-51 600 ln/min 105 gVQC2A01n-51 460 ln/min 105 gVQC2B01n-51 460 ln/min 105 gVQC2C01n-51 460 ln/min 105 g

B C D

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

VQC2000 – solenoid valve, plug-inMedium Air, lubricated or not lubricated (dry)

Degree of filtrationMax. working pressure

Min. working pressure

5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar); metal seal (not double 3/2): 0.1 MPa (1 bar)

Operating temperature up to 50 °C (dry air)

Voltage/power Standard: 24 VDC ±10% (12 VDC on request)/0.4 W

Flow See table below

Enclosure IP67, factory-assembled in japan; otherwise IP65; D-sub or flat cable, IP50

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard

■ unmatched flexibility and easy configuration because of new internal connector technology

Sub plates – basic type, add electrical connection below.

Part number Stations

Additions – for sub plates above

AdditionsBuilt-in silencer (…SD0-S) Manifold 13–24 valve stations/added station1 Separate pilot supply (…SD0-R)/manifold

1. Note! Manifold specification required; contact SMC.

Electrical connections – interface modules

Part number TypeD-sub, 25-pinFlat cable, 26-pinCircular connector, 26-pin (IP67)Terminal box, 20 connections (IP67)Molded cable, 0.6 mMolded cable, 1.5 mMolded cable, 3 m

Fieldbus – EX250, EX500 and EX600, see chapter 5

replacement fittingPart number = C4 for Ø4 mm; C6 for Ø6 mm; C8 for Ø8 mm.

Parallel fitting – 2 valve stations

Part number

Silencer – for exhaust

Part number

Blanking plate – for unused valve stations

Part number

Blanking plug – in place of unused connections

Part number = 04 for Ø4 mm; 06 for Ø6 mm; 08 for Ø8 mm.

Blanking plug – in place of fitting

Part number

Individual P-supplyPart number

Valve – plug-in, 24 VDC

Part number1 Type Flow Weight5/2 mono stable, rubber seal5/2 mono stable, metal seal5/2 bi stable, rubber seal5/2 bi stable, metal seal5/3 closed center, rubber seal5/3 exhausted center, rubber seal5/3 pressurized center, rubber sealDouble 3/2 nC/nC, rubber sealDouble 3/2 nO/nO, rubber sealDouble 3/2 nC/nO, rubber seal

1. For lockable manual override, add B, C or D at end of part number. Example: VQC2101n-51B.

Blanking plateParallel fitting

Manual override versions

Page 45: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

91■

VVQ2000-24A-1

VVQ2000-16A

VVQ2000-R-1-C8

VVQ2000-19A

VVQ2000-18A

VVQC2000-1A-D-C8VVQC2000-1A-S-C8

VQ2000-PW-02FVQ2000-PW-02F-XSE502

VVQ2000-n-

VVQ2000-57A

VVZS3000-21A-2*VVZS3000-21A-3*VVZS3000-21A-4*

AXT100-MC26AXT100-MC26-015AXT100-MC26-030AXT100-MC26-050AXT100-MC26-080

VQC 2 10 -➊

1 0 n 5➋ ➌ ➎ ➏➍

➊12345ABC

➋01

B

Knr

➍5 24 VDC1

6 12 VDC

E

B

C

D

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Sandwichmodul – for individual P-shut-off

Part number

Blocking disc – supply

Part number

Individual r-exhaustPart number

Blocking disc – exhaust

Part number

Check valve – prevents back pressure from R-channel

Part number

Expansion part – standard

Part number TypeFor double solenoidFor single solenoid

Sub plate – single assembly

Part number TypeStandardWith M12 connection

name platePart number = number of valve stations.

DIn rail brackets – 1 pair

Part number

D-sub connector – 25-pin, in accordance with MIL-norm (0.3 mm2)

Part number TypeConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

Circular connector – 26-pin (IP67), with cable

Part number TypeConnector onlyConnector with 1.5 m cableConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

For output modules VQC2000 – electrical accessories, see EX250/-500 fieldbus.

For other versions, contact SMC.For fieldbus components, see chapter 5.

VQC2000 – solenoid valve, plug-in

Individual P-supply

Blocking disc – supply

Name plate

Individual R-exhaust

Blocking disc – exhaust

Sandwichmodul – for individual

P-shut-off

Part number: valve – for valve manifold, see next page

Series VQC2000

Function

5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized centerDouble 3/2 nC/nC1

Double 3/2 nO/nO1

Double 3/2 nC/nO1

1. Only available with rubber seal.

Seal type

Metal sealRubber seal

Options

Standard (0.4 W)Quick response time (12 ms)1

High pressure (1 MPa)2

negative commonExternal pilot3

When more than one option is desired, enter them in alphabetical order.1. 0.95 W2. Only available with metal seal, 0.95 W.3. not available for double 3/2 valve.

rated voltage

1. Fieldbus connection only available for 24 VDC.

LeD/surge voltage suppressor

WithWithout LED, with surge voltage suppressor1

1. not for fieldbus connection.

Manual override

non-locking push type (tool required)Locking for screwdriver (tool required)Locking type (manual)Locking sliding type (manual)

Valve stations are numbered in ascending order, starting from D-side

D-side U-sideValve stations 1 2 3 4 5 6 7 8

1

32

65

4

78

Page 46: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

92 ■

➋C4 C6 C8

CM

l4

l6

l8

B3

B4

B6

B8

lM

➊01

FD0FD1FD2FD3PD0PD1PD2PD3

PDC

TD0

lD0lD1lD2MD0MD1MD2MD3

SD0ASDA1

SDA2

SD0SDQSDnSDVSDy

SDTA

SDTB

SDTC

SDTD

SDVB

B

D

D

K

nr

S

T

01 8

123

n nPn (–)

➍EX250 EX500 EX126

Dev

icen

et

Pr

OFI

Bu

S-

DP

CC

-lIn

K

AS

-i

CA

no

pen

Dev

icen

et

Pr

OFI

Bu

S-

DP

CC

-lIn

K

rem

ote

I/O

CC

-lIn

K

+COM — — ✔ — — ✔ ✔ ✔ ✔ ✔n –COM ✔ ✔ — ✔ ✔ ✔ ✔ ✔ ✔ —

VV5QC - 08 B2 1 C8 FD1 F / P T l M/ / /VV5QC - 08 B-2 1 C8 SDQ S

➊ ➋ ➌ ➍ ➎ ➏ ➐ ➑

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Cylinder port size

Push-in, Ø4 mmPush-in, Ø6 mmPush-in, Ø8 mmMixed sizes or with port plugTop-connected angle with push-in, Ø4 mmTop-connected angle with push-in, Ø6 mmTop-connected angle with push-in, Ø8 mmBottom-connected angle with push-in, Ø3 mmBottom-connected angle with push-in, Ø4 mmBottom-connected angle with push-in, Ø6 mmBottom-connected angle with push-in, Ø8 mmAngle connector, mixed sizes

When selecting CM/LM, enter size in manifold specification sheet.

number of valve stations

1 station

Maximum number of valve stations de-pends on chosen electrical connection. See Electrical connection/cable length.

Electrical connection/cable lengthInput

D-side Connection/cable lengthValve

stations2

F co

nn. D-sub connector (25P) without cable

1 to 12 (24)

D-sub connector (25P) w. 1.5 m cableD-sub connector (25P) w. 3 m cableD-sub connector (25P) w. 5 m cable

P c

onn

.

Flat cable (26P) without cable1 to 12

(24)Flat cable (26P) with 1.5 m cableFlat cable (26P) with 3 m cableFlat cable (26P) with 5 m cable

Flat cable (20P) without cable1 1 to 9 (18)

T c

onn

.

Terminal connection in box 1 to 10 (20)

l co

nn. Cable (25 wire), 0.6 m wire length

1 to 12 (24)Cable (25 wire), 1.5 m wire length

Cable (25 wire), 3 m wire length

M c

onn

. Multipole connector (26P) without cable1 to 12

(24)Multipole connector (26P) with 1.5 m cableMultipole connector (26P) with 3 m cableMultipole connector (26P) with 5 m cable

S c

onn

ecti

on

Distributed fieldbus (EX500)For fieldbus without fieldbus node

1 to 8 (16)

With fieldbus node for Remote I/OWith fieldbus node for Devicenet/ PROFIBuS-DP/CC-LInK

Fieldbus with in- and outputs (EX250)For fieldbus without fieldbus node

1 to 12 (24)

Fieldbus for DevicenetFieldbus for PROFIBuS-DPFieldbus for CC-LInKFieldbus for CAnopenAS-i, 8 in/8 out, 31-slave model, 2 power supplies

1 to 4 (8)

AS-i, 4 in/4 out, 31-slave model, 2 power supplies

1 to 2 (4)

AS-i, 8 in/8 out, 31-slave model, 1 power supply

1 to 4 (8)

AS-i, 4 in/4 out, 31-slave model, 1 power supply

1 to 2 (4)

Fieldbus with outputs (EX126)

Fieldbus for CC-LInK 1 to 8 (16)

1. P connection: Order cables separately for type 20P.2. numbers in paranthesis indicates maximum number of solenoids for configuration w. mixed single-double solenoid connections. Maximum number of valve stations is determined by total number of solenoids. For mixed connections, use option symbol “K”.

Options

noneAll stations with back-pressure check valves1

With DIn rail (rail length: standard)With DIn rail (rail length: special)2

Special wiring (not double wiring)3

With name plateExternal pilot4

Direct exhaust with built-in silencer5

Branch off P- and R-ports on u-side6

Specify options in alphabetical order. Example: BRS.1. When using backpressure check valves only on neccessary stations, en-ter check valve part number and valve station number in manifold specifica-tion sheet.2. For special DIn rail length, enter D. ( = number of valve stations.) Example: D08. In this case, manifold is mounted on DIn rail for 8 stations, regardless of actual number of stations in manifold. Entered number of stations must be larger than actual number of stations in manifold. Enter D0 for op-tions without DIn rail.3. Ensure that wiring is entered in manifold specification sheet.4. For external pilot option “R”, also enter external pilot option “R” for valves in question.5. Option with built-in silencer does not meet requirement of IP67.6. SuP and EXH ports on u-side branch off (against cylinder port and solenoid) with push-in fitting.

Input block (only entered when

input blocks are used)

Without fieldbus node/input block (SD0)Without input blockWith 1 input block With 8 input blocks

Type of input block (only

entered when input blocks are used)

Without input blockM12, 2 inputsM12, 4 inputsM8, 4 inputs (3 pins)

Polarity, input block (only entered when input blocks

are used)

PnP (+) or without fieldbus node/ input block

Fieldbus polarity

Polarity

Leave box for fieldbus polarity blank for manifold without bus node (SD0).

Part number: valve manifold – for VQC2000 plate assembly/plug-in unit

connection

connection

Series VQC2000

Plate assembly/plug-in

VQC2000 – solenoid valve, plug-in

Page 47: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

93■

EX

250

EX

260

EX

500

EX

600

EX

126

D-s

ub

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Exploded view VQC2000Electrical connection

and fieldbus End plate, D-side Valve station, base End plate, u-side

S c

onn

ecti

on

(fiel

db

us)

F co

nnec

tio

nP

co

nnec

tio

n

Flat

cab

le

T c

onn

ecti

on

Term

inal

con

n.

l co

nnec

tio

n

Sin

gle

wire

M c

onn

ecti

on

Mul

tipol

e co

nn.

VQC2000 – solenoid valve, plug-in

Page 48: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

94 ■

5 µm1.0 MPa (10 bar)

VV5QC41-0203FSD0 2 G3/8VV5QC41-0403FSD0 4 G3/8VV5QC41-0603FSD0 6 G3/8VV5QC41-0803FSD0 8 G3/8VV5QC41-1003FSD0 10 G3/8VV5QC41-1203FSD0 12 G3/8

VQ4000-PW-03F-QVQ4000-PW-03F-Q-XSE502

VVQC1000-F25-1VVQC1000-P20-1VVQC1000-P26-1

VVQC1000-M26-1

VVQC1000-T0-1

VVQ4000-10A-1

VVQ4000-P-1-03F

VVQ4000-16A

VVQ4000-R-1-03F

VVQ4000-16A

VVQ4000-20A-1

VQC4101-5 2000 ln/min 230 gVQC4100-5 1700 ln/min 230 gVQC4201-5 2000 ln/min 260 gVQC4200-5 1700 ln/min 260 gVQC4301-5 1900 ln/min 280 gVQC4401-5 2000 ln/min 280 gVQC4501-5 2000 ln/min 280 g

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

VQC4000 – solenoid valve, plug-inMedium Air, lubricated or not lubricated (dry)

Degree of filtrationMax. working pressure

Min. working pressure

5/2 mono stable: 0.2 MPa (2 bar); 5/2 bi stable: 0.15 MPa (1.5 bar); 5/3 with center position: 0.2 MPa (2 bar); metal seal (all): 0.15 MPa (1.5 bar)

Operating temperature up to 50 °C (dry air)

Voltage/power Standard: 24 VDC ±10% (12 VDC on request)/1 W

Flow See table below

Enclosure IP67, factory-assembled in japan; otherwise IP65; D-sub or flat cable, IP50

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard

■ unmatched flexibility and easy configuration because of new internal connector technology

Sub plates – basic type, add electrical connection below.

Part number Stations Connection

Available with interchangeable push-in fittings Ø8, 10 or 12 mm; contact SMC.For built-in silencer, add “-S” after SD0. Example: VV5QC41-0203FSD0-S.

Sub plate – single assembly

Part number TypeStandardWith M12 connection

Additions – for sub plates above

AdditionsManifold 13–24 valve stations/added station1

1. Note! Manifold specification required; for terminal box and 20-pin flat cable some restrictions apply; contact SMC.

Electrical connections – interface modules

Part number TypeD-sub, 25-pinFlat cable, 20-pinFlat cable, 26-pinCircular connector, 26-pin (IP67)Terminal box, 20 connections (IP67)

For molded cable (L connection), contact SMC.

Fieldbus – EX250, EX500 and EX600, see chapter 5

Blanking plate – for unused valve stations

Part number

Individual P-supplyPart number

Blocking disc – supply

Part number

Individual r-exhaustPart number

Blocking disc – exhaust

Part number

Throttle valve block – mounted between valve and manifold

Part number

Valve – plug-in, 24 VDC

Part number1 Type Flow Weight5/2 mono stable, rubber seal5/2 mono stable, metal seal5/2 bi stable, rubber seal5/2 bi stable, metal seal5/3 closed center, rubber seal5/3 exhausted center, rubber seal5/3 pressurized center, rubber seal

1. For lockable manual override, add B at end of part number. Example: VQC4101n-5B.

Blanking plate

Page 49: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

95■

VVQ4000-25A-1

VVQ4000-37A-1

ARBQ4000-00-P-1 PARBQ4000-00-A-1 AARBQ4000-00-B-1 B

VVQC4000-1A-D-03FVVQC4000-1A-S-03F

VVZS3000-21A-2*VVZS3000-21A-3*VVZS3000-21A-4*

AXT100-MC26AXT100-MC26-015AXT100-MC26-030AXT100-MC26-050AXT100-MC26-080

VQC 4 0 -➊

1 0 5➋ ➌ ➎ ➏➍

➊12345

6

➋01

ry

➍5 24 VDC1

6 12 VDC

E

B

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Pressure-controlled check valve – w. manual residual pressure relief

Part number

Note! Can not be mounted on manifold with external pilot supply.

Individual shut-off for P-supplyPart number

Sandwich regulatorPart number regulated port

Expansion part – standard

Part number TypeFor double solenoidFor single solenoid

D-sub connector – 25-pin, in accordance with MIL-norm (0.3 mm2)

Part number TypeConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

Circular connector – 26-pin (IP67), with cable

Part number TypeConnector onlyConnector with 1.5 m cableConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

For output modules VQC4000 – electrical accessories, see EX250/-500 fieldbus.

For other versions, contact SMC.For fieldbus components, see chapter 5.

Part number: valve – for valve manifold, see next page

Series VQC4000

Function

5/2 mono stable5/2 bi stable5/3 closed center5/3 exhausted center5/3 pressurized center5/3 exhausted center with pressure-controlled check valves

Seal type

Metal sealRubber seal

Options

Standard (1 W)External pilotLow power (0.5 W)

When more than one option is desired, enter them in alphabetical order.

rated voltage

1. Fieldbus connection only available for 24 VDC.

LeD/surge voltage suppressor

WithWithout LED, with surge voltage suppressor

Manual override

non-locking push type (tool required)Locking for screwdriver (tool required)

VQC4000 – solenoid valve, plug-in

Individual P-supply

Blocking disc – supply

Individual R-exhaust

Blocking disc – exhaust

Throttle valve block

Pressure-controlled check valve

Individual shut-off for P-supply

Sandwich regulator

Valve stations are numbered in ascending order, starting from D-side

D-side

U-side

Valve stations

1

2

3

4

5

6

7

8

Page 50: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

96 ■

➋C8 C10 C12 02 Rc1/403 Rc3/8B

CM

➊01

FD0FD1FD2FD3PD0PD1PD2PD3

PDC

TD0

lD0lD1lD2MD0MD1MD2MD3

SD0ASDA1

SDA2

SD0SDQSDnSDVSDy

SDTA

SDTB

SDTC

SDTD

SD0WSDQWSDnWSDVW

SDVB

K

n

01 8

1234

n nPn (–)

➍EX240 EX250 EX500 EX126

Dev

icen

et

Pr

OFI

Bu

S-

DP

Dev

icen

et

Pr

OFI

Bu

S-

DP

CC

-lIn

K

AS

-i

CA

no

pen

Dev

icen

et

Pr

OFI

Bu

S-

DP

CC

-lIn

K

rem

ote

I/O

CC

-lIn

K

+COM ✔ — — — ✔ — — ✔ ✔ ✔ ✔ ✔n –COM ✔ ✔ ✔ ✔ — ✔ ✔ ✔ ✔ ✔ ✔ —

VV5QC - 084 1 02 TD0 F / P T l M/ / /VV5QC - 08 -4 1 02 SDQW S

➊ ➋ ➌ ➍ ➎ ➏ ➐ ➑

VV5QC41-08 03 TD0

RcF GT nPT/nPTF

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Cylinder port size

Push-in, Ø8 mmPush-in, Ø10 mmPush-in, Ø12 mm

Bottom-connected Rc1/4Mixed sizes or with port plug

When selecting CM, enter size in manifold specification sheet.

number of valve stations

1 station

Maximum number of valve stations de-pends on chosen electrical connection. See Electrical connection/cable length.

Electrical connection/cable lengthInput

D-side Connection/cable lengthValve

stations2

F co

nn. D-sub connector (25P) without cable

1 to 12 (24)

D-sub connector (25P) with 1.5 m cableD-sub connector (25P) with 3 m cableD-sub connector (25P) with 5 m cable

P c

onn

.

Flat cable (26P) without cable1 to 12

(24)Flat cable (26P) with 1.5 m cableFlat cable (26P) with 3 m cableFlat cable (26P) with 5 m cable

Flat cable (20P) without cable1 1 to 9 (18)

T c

onn

.

Terminal connection in box 1 to 10 (20)

l co

nn. Cable (25 wire), 0.6 m wire length

1 to 12 (24)Cable (25 wire), 1.5 m wire length

Cable (25 wire), 3 m wire length

M c

onn

. Multipole connector (26P) without cable1 to 12

(24)Multipole connector (26P) with 1.5 m cableMultipole connector (26P) with 3 m cableMultipole connector (26P) with 5 m cable

S c

onn

ecti

on

Distributed fieldbus (EX500)For fieldbus without fieldbus node

1 to 8 (16)

With fieldbus node for Remote I/OWith fieldbus node for Devicenet/ PROFI-BuS-DP/CC-LInK

Fieldbus with in- and outputs (EX250)For fieldbus without fieldbus node

1 to 12 (24)

Fieldbus for DevicenetFieldbus for PROFIBuS-DPFieldbus for CC-LInKFieldbus for CAnopenAS-i, 8 in/8 out, 31-slave model, 2 power supplies

1 to 4 (8)

AS-i, 4 in/4 out, 31-slave model, 2 power supplies

1 to 2 4)

AS-i, 8 in/8 out, 31-slave model, 1 power supply

1 to 4 (8)

AS-i, 4 in/4 out, 31-slave model, 1 power supply

1 to 2 (4)

Fieldbus with in- and outputs (EX240)For fieldbus without fieldbus node

1 to 12 (24)

Fieldbus for DevicenetFieldbus for PROFIBuS-DPFieldbus for CC-LInK

Fieldbus with outputs (EX126)

Fieldbus for CC-LInK 1 to 8 (16)

1. P connection: Order cables separately for type 20P.2. numbers in paranthesis indicates maximum number of solenoids for configuration w. mixed single-double solenoid connections. Maximum number of valve stations is determined by total number of solenoids. For mixed connections, use option symbol “K”.

Options

noneSpecial wiring (not double wiring)1

With name plate (only available for T connection)2

When more than one option is desired, enter them in alphabetical order. Example: Kn.1. Ensure that wiring is entered in manifold specification sheet.2. Mounting position for name plate is on top of terminal box cover.

Input block (only entered when

input blocks are used)

Without fieldbus node/input block (SD0)Without input blockWith 1 input block With 8 input blocks

Max. 4 for EX240 and max. 8 for EX250.

Type of input block (only

entered when input blocks are used)

Without input blockM12, 8 inputs (EX240)M12, 2 inputs (EX250)M12, 4 inputs (EX250)M8, 4 inputs (EX250)

Polarity, input block (only entered when input blocks

are used)

PnP (+) or without field-bus node/input block

Fieldbus polarity

Polarity

Leave box for fieldbus polarity blank for manifold without bus node (SD0).

Part number: valve manifold – for VQC4000 plate assembly/plug-in unit

connection

connection

Series VQC4000

Plate assembly/plug-in

Thread – for P, R, A, B port

Cylinder port Thread type

P- and R-ports use same thread

VQC4000 – solenoid valve, plug-in

Page 51: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

97■

EX

250

EX

260

EX

500

EX

600

EX

240

EX

126

D-s

ub

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Exploded view VQC4000Electrical connection

and fieldbus End plate, D-side Valve station, base End plate, u-side

S c

onn

ecti

on

(fiel

db

us)

F co

nn.

P c

onn

.

Flat

cab

le

T c

onn

ecti

on

Term

inal

con

n.

l co

nnec

tio

n

Sin

gle

wire

M c

onn

ecti

on

Mul

tipol

e co

nn.

VQC4000 – solenoid valve, plug-in

Page 52: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

98 ■

5 µm1.0 MPa (10 bar)

4000 ln/min

5 µm0.7 MPa (7 bar)

290 ln/minIP67

SV1100-5Fu 66 g

SV1100R-5Fu 66 g

SV1200-5Fu 71 g

SV1200R-5Fu 71 g

SV1300-5Fu 73 g

SV1300R-5Fu 73 g

SV1400-5Fu 73 g

SV1400R-5Fu 73 g

SV1500-5Fu 73 g

SV1500R-5Fu 73 g

SV1A00-5Fu 71 gSV1B00-5Fu 71 gSV1C00-5Fu 71 g

SV1000-60-5A-1A

SV1000-60-5B-1A

SS5V1-W10S10D-02D-C6 2SS5V1-W10S10D-04B-C6 4SS5V1-W10S10D-06B-C6 6SS5V1-W10S10D-08B-C6 8SS5V1-W10S10D-10B-C6 10SS5V1-W10S10D-12B-C6 12SS5V1-W10S10D-14B-C6 14SS5V1-W10S10D-16B-C6 16SS5V1-W10S10D-18B-C6 18SS5V1-W10S10D-20B-C6 20

VVQC1000-F25-1VVQC1000-P26-1

VVQC1000-M26-1

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

VQ5000 – solenoid valve, plug-inMedium Compressed air, lubricated or not lubricated

Degree of filtrationMax. working pressure

Min. working pressure (rubber seal/metal seal)

5/2 mono stable: 0.2 MPa (2 bar)/0.1 MPa (1 bar); 5/2 bi stable: 0.15 MPa (1.5 bar)/0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar)/0.15 MPa (1.5 bar)

Operating temperature –10 to 50 °C (dry air)Voltage/power 24 VDC ±10% (other voltages on request)/1 W

FlowEnclosure IP65 (except for D-sub)

Manual override Standard: non-lockable (lockable on request)LeD, surge voltage suppressor Standard

For more information, contact SMC.

■ More compact than ISO 3 ■ Lower weight ■ More accessories

SV1000 – solenoid valve, tie rod typeMedium Air, lubricated or not lubricated (dry)

Degree of filtrationMax. working pressure

Min. working pressure

5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar)

Operating temperature up to 50 °C (dry air)

Voltage/power Standard: 24 VDC (12 VDC on request)/0.65 W

FlowEnclosure

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard, valve has no polarity

■ Easy to expand, connectors between valves ■ Highest enclosure IP67

Valve – plug-in

Part number1 Type Weight5/2 mono stable, rubber seal5/2 mono stable, rubber seal, external pilot5/2 bi stable, rubber seal5/2 bi stable, rubber seal, external pilot5/3 closed center, rubber seal5/3 closed center, rubber seal, external pilot5/3 exhausted center, rubber seal5/3 exhausted center, rubber seal, external pilot 5/3 pressurized center, rubber seal5/3 pressurized center, rubber seal, external pilot 5/4 double 3/2, nC/nC, rubber seal5/4 double 3/2, nO/nO, rubber seal5/4 double 3/2, nC/nO, rubber seal

1. Add D for lockable manual override. Example: SV1100-5FuD.

Output modules – for electrical accessories, see EX500 fieldbus

Part number Type1

One normally open relay output, 110 VAC/3 A, 30 VDC/3 ATwo normally open relay outputs, 110 VAC/0.3 A, 30 VDC/1 A

1. Load capacity for resistive loads.

Sub plates – basic type1, add electrical connection below

Part number number of stations

1. For other versions, contact SMC.

Electrical connections – interface modules

Part number TypeD-sub, 25-pinFlat cable, 26-pinCircular connector, 26-pin (IP67)

Fieldbus – EX250, EX260, EX500 and EX600, see chapter 5

use interface for VQC series for sub plates above.

Page 53: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

99■

5 µm0.7 MPa (7 bar)

290 ln/minIP67

SV1100-5Fu 66 g

SV1100R-5Fu 66 g

SV1200-5Fu 71 g

SV1200R-5Fu 71 g

SV1300-5Fu 73 g

SV1300R-5Fu 73 g

SV1400-5Fu 73 g

SV1400R-5Fu 73 g

SV1500-5Fu 73 g

SV1500R-5Fu 73 g

SV1A00-5Fu 71 gSV1B00-5Fu 71 gSV1C00-5Fu 71 g

SV1000-60-5A-1A

SV1000-60-5B-1A

SS5V1-W16CD-02D-C6 SS5V1-W16S0D-02D-C6

SS5V1-16FD1-02D-C6SS5V1-16PD1-02D-C6

SS5V1--02D-C6 2SS5V1--04D-C6 4SS5V1--06D-C6 6SS5V1--08D-C6 8SS5V1--10D-C6 10SS5V1--12B-C6 12SS5V1--14B-C6 14SS5V1--16B-C6 16SS5V1--18B-C6 18

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

SV1000 – solenoid valve, cassette typeMedium Air, lubricated or not lubricated (dry)

Degree of filtrationMax. working pressure

Min. working pressure

5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar)

Operating temperature up to 50 °C (dry air)

Voltage/power Standard: 24 VDC (12 VDC on request)/0.65 W

FlowEnclosure

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard, valve has no polarity

■ unmatched flexibility ■ Easy to assemble, expand and modify

Valve – plug-in

Part number1 Type Weight5/2 mono stable, rubber seal5/2 mono stable, rubber seal, external pilot5/2 bi stable, rubber seal5/2 bi stable, rubber seal, external pilot5/3 closed center, rubber seal5/3 closed center, rubber seal, external pilot5/3 exhausted center, rubber seal5/3 exhausted center, rubber seal, external pilot 5/3 pressurized center, rubber seal5/3 pressurized center, rubber seal, external pilot 5/4 double 3/2, nC/nC, rubber seal5/4 double 3/2, nO/nO, rubber seal5/4 double 3/2, nC/nO, rubber seal

1. Add D for lockable manual override. Example: SV1100-5FuD.

Output modules – 24 VDC. For electrical accessories, see EX250/-500 fieldbus.

Part number Type1

One normally open relay output, 110 VAC/3 A, 30 VDC/3 ATwo normally open relay outputs, 110 VAC/0.3 A, 30 VDC/1 A

1. Load capacity for resistive loads.

Sub plates – cassette type (16)

Sub plate Example of part numberMultipole connection, IP67For EX500 Gateway (Gateway parts ordered separately), IP67D-sub connection, IP40Flat cable connection, IP40

Part number number of stations

For other versions, contact SMC. For fieldbus compo-nents, see chapter 5.

Page 54: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

100 ■

VVQ1000-50A-

An203-KM8

SV1000-67-1A

SV1000-38-1A-C6

SV1000-39-1A-C6

SV1000-05-P PSV1000-05-A1 ASV1000-05-B1 BSV1300-05-P PSV1300-05-A1 ASV1300-05-B1 B

KQ2P-

VVQ1000-58A

SV1000-74-1A

GVVZS3000-21A-2GVVZS3000-21A-3GVVZS3000-21A-4

AXT100-MC26AXT100-MC26-015AXT100-MC26-030AXT100-MC26-050AXT100-MC26-080

SV1000-59-1A

SV1000-59-2A

SV1000-50-1A-

SV1000-50-2A-

SX3000-77-1A

SX3000-77-1A

SV1000-50-3A-

SV1000-50-4A-

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

Accessories for SV1000 – solenoid valve, tie rod and cassette type

replacement fittingPart number = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Silencer – for exhaust

Part number

Blanking platePart number

Individual P-supplyPart number

Individual r-exhaustPart number

Sandwich regulator – with pressure gauge

Part number regulated port For valve type

Mono- and bi stable

For 3-position

Blanking plug – in place of unused connections

Part number = 03 for Ø3.2 mm; 04 for Ø4 mm; 06 for Ø6 mm.

Blanking plug – in place of fitting

Part number

Blocking indicatorPart number

D-sub connector – 25-pin, in accordance with MIL-norm (0.3 mm2)

Part number TypeConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

Circular connector – 26-pin (IP67), with cable

Part number TypeConnector onlyConnector with 1.5 m cableConnector with 3 m cableConnector with 5 m cableConnector with 8 m cable

Blocking disc – supply

Part number

Blocking disc – exhaust

Part number

Expansion part – single solenoid

Part number = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Expansion part – double solenoid

Part number = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Blanking plate Expansion part

For manifold type 10S

For manifold type 16S

Blocking disc – supply

Part number

Blocking disc – exhaust

Part number

Expansion part – single solenoid

Part number = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Expansion part – double solenoid

Part number = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Page 55: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

101■

5 µm0.7 MPa (7 bar)

580 ln/minIP67

SV2100-5Fu 74 g

SV2100R-5Fu 74 g

SV2200-5Fu 78 g

SV2200R-5Fu 78 g

SV2300-5Fu 83 g

SV2300R-5Fu 83 g

SV2400-5Fu 83 g

SV2400R-5Fu 83 g

SV2500-5Fu 83 g

SV2500R-5Fu 83 g

SV2A00-5Fu 78 gSV2B00-5Fu 78 gSV2C00-5Fu 78 g

SV2000-60-5A-1A

SV2000-60-5B-1A

SS5V2-W10S10D-02D-C8 2SS5V2-W10S10D-04D-C8 4SS5V2-W10S10D-06D-C8 6SS5V2-W10S10D-08D-C8 8SS5V2-W10S10D-10D-C8 10SS5V2-W10S10D-12B-C8 12SS5V2-W10S10D-14B-C8 14SS5V2-W10S10D-16B-C8 16SS5V2-W10S10D-18B-C8 18SS5V2-W10S10D-20B-C8 20

VVQC1000-F25-1VVQC1000-P26-1

VVQC1000-M26-1

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

SV2000 – solenoid valve, tie rod typeMedium Air, lubricated or not lubricated (dry)

Degree of filtrationMax. working pressure

Min. working pressure

5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar)

Operating temperature up to 50 °C (dry air)

Voltage/power Standard: 24 VDC (12 VDC on request)/0.65 W

FlowEnclosure

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard, valve has no polarity

■ Easy to expand, connectors between valves ■ Highest enclosure IP67

Valve – plug-in

Part number1 Type Weight5/2 mono stable, rubber seal5/2 mono stable, rubber seal, external pilot5/2 bi stable, rubber seal5/2 bi stable, rubber seal, external pilot5/3 closed center, rubber seal5/3 closed center, rubber seal, external pilot5/3 exhausted center, rubber seal5/3 exhausted center, rubber seal, external pilot 5/3 pressurized center, rubber seal5/3 pressurized center, rubber seal, external pilot 5/4 double 3/2, nC/nC, rubber seal5/4 double 3/2, nO/nO, rubber seal5/4 double 3/2, nC/nO, rubber seal

1. Add D for lockable manual override. Example: SV2100-5FuD

Output modules – for electrical accessories, see EX500 fieldbus

Part number Type1

One normally open relay output, 110 VAC/3 A, 30 VDC/3 ATwo normally open relay outputs, 110 VAC/0.3 A, 30 VDC/1 A

1. Load capacity for resistive loads.

Sub plates – basic type1, add electrical connection below

Part number number of stations

1. For other versions, contact SMC.

Electrical connections – interface modules

Part number TypeD-sub, 25-pinFlat cable, 26-pinCircular connector, 26-pin (IP67)

Fieldbus – EX250, EX260, EX500 and EX600, see chapter 5

use interface for VQC series for sub plates above.

Page 56: Solenoid valves, mechanical and manual valves · VXZ22 & -23 – zero differential pressure solenoid Cv 1.9–12 155 VXS22 & -23 – zero differential pressure Cv 2.4–12 156 V Cv

4

102 ■

5 µm0.7 MPa (7 bar)

520 ln/minIP67

SV2100-5Fu 74 g

SV2100R-5Fu 74 g

SV2200-5Fu 78 g

SV2200R-5Fu 78 g

SV2300-5Fu 83 g

SV2300R-5Fu 83 g

SV2400-5Fu 83 g

SV2400R-5Fu 83 g

SV2500-5Fu 83 g

SV2500R-5Fu 83 g

SV2A00-5Fu 78 gSV2B00-5Fu 78 gSV2C00-5Fu 78 g

SV2000-60-5A-1A

SV2000-60-5B-1A

SS5V2-W16CD-02D-C8 SS5V2-W16S0D-02D-C8

SS5V2-16FD1-02D-C8SS5V2-16PD1-02D-C8

SS5V2--02D-C8 2SS5V2--04D-C8 4SS5V2--06D-C8 6SS5V2--08D-C8 8SS5V2--10D-C8 10SS5V2--12B-C8 12SS5V2--14B-C8 14SS5V2--16B-C8 16SS5V2--18B-C8 18

Sub

ject

to

cha

nge

SOlEnOID VAlVES, MEChAnICAl AnD MAnuAl VAlVES

= DElIVEry EX-STOCK FOr MOrE InFO, ASK ThE SMC EXPErTS: PhOnE +31 (0) 20 531 88 88 / [email protected]

SV2000 – solenoid valve, cassette typeMedium Air, lubricated or not lubricated (dry)

Degree of filtrationMax. working pressure

Min. working pressure

5/2 mono stable: 0.15 MPa (1.5 bar); 5/2 bi stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar)

Operating temperature up to 50 °C (dry air)

Voltage/power Standard: 24 VDC (12 VDC on request)/0.65 W

FlowEnclosure

Manual override Standard: non-lockableLeD, surge voltage suppressor Standard, valve has no polarity

■ unmatched flexibility ■ Easy to assemble, expand and modify

Valve – plug-in

Part number1 Type Weight5/2 mono stable, rubber seal5/2 mono stable, rubber seal, external pilot5/2 bi stable, rubber seal5/2 bi stable, rubber seal, external pilot5/3 closed center, rubber seal5/3 closed center, rubber seal, external pilot5/3 exhausted center, rubber seal5/3 exhausted center, rubber seal, external pilot 5/3 pressurized center, rubber seal5/3 pressurized center, rubber seal, external pilot 5/4 double 3/2, nC/nC, rubber seal5/4 double 3/2, nO/nO, rubber seal5/4 double 3/2, nC/nO, rubber seal

1. Add D for lockable manual override. Example: SV2100-5FuD.

Output modules – 24 VDC. For electrical accessories, see EX250/-500 fieldbus.

Part number Type1

One normally open relay output, 110 VAC/3 A, 30 VDC/3 ATwo normally open relay outputs, 110 VAC/0.3 A, 30 VDC/1 A

1. Load capacity for resistive loads.

Sub plates – cassette type (16)

Sub plate Example of part numberMultipole connection, IP67For EX500 Gateway (Gateway parts ordered separately), IP67D-sub connection, IP40Flat cable connection, IP40

Part number number of stations

For other versions, contact SMC. For fieldbus compo-nents, see chapter 5.